SHE-PHYSICAL-MIB

File: SHE-PHYSICAL-MIB.mib (124621 bytes)

Imported modules

AN-MIB ENTITY-MIB IF-MIB
SHE-ALARMING-MIB SHE-TC-MIB SNMP-FRAMEWORK-MIB
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC

Imported symbols

she entPhysicalIndex PhysicalIndex
ifIndex ifAdminStatus ifOperStatus
InterfaceIndex sheAlarmTimeAndDate sheAlarmReportingSource
sheAlarmReportingSourceType sheAlarmSeverity SheAlarmSevProfileIndex
SheControlStatusType SheAdminStateType ShePermissionType
SnmpAdminString OBJECT-GROUP MODULE-COMPLIANCE
NOTIFICATION-GROUP Integer32 Unsigned32
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
DisplayString TruthValue TEXTUAL-CONVENTION

Defined Types

ShePhysSlotStatusType  
The slot status type
TEXTUAL-CONVENTION    
  INTEGER empty(1), used(2)  

ShePhysCardAdminStateType  
The adminstrative state type for cards.
TEXTUAL-CONVENTION    
  INTEGER unlocked(1), locked(2), notEquipped(3), planned(4)  

ShePhysAvailabilityStateType  
The availability state type
TEXTUAL-CONVENTION    
  INTEGER available(1), failed(2), degraded(3), offline(4), notInstalled(5), dependency(7)  

ShePhysCardOperStateType  
The operational state type for cards.
TEXTUAL-CONVENTION    
  INTEGER enabled(1), disabled(2)  

ShePhysProtectionCapabilityType  
The protection modes a card can work (1=mode possible). bit 0: standalone mode bit 1: protection mode
TEXTUAL-CONVENTION    
  INTEGER 0..3  

ShePhysProtectionModeType  
The protection mode in which a card works.
TEXTUAL-CONVENTION    
  INTEGER standaloneMode(1), protectionMode(2)  

ShePhysDefaultRoleType  
The default role type.
TEXTUAL-CONVENTION    
  INTEGER protecting(1), working(2)  

ShePhysDynamicRoleType  
The dynamic role type.
TEXTUAL-CONVENTION    
  INTEGER active(1), standby(2), notDefined(3)  

ShePhysProtState  
The protection state type.
TEXTUAL-CONVENTION    
  INTEGER unknown(1), activeNoRedundancy(2), activeProtected(3), activeDegraded(4), standbyNotPresent(5), standbyBooting(6), standbyProtecting(7), standbyDegraded(8)  

ShePhysUpgradeStateType  
The upgrade state type.
TEXTUAL-CONVENTION    
  INTEGER none(0), upgradeInitialized(1), upgradeToDo(2), upgradeStarted(3), upgradeCrashed(4), upgradeFtpDone(5), upgradeDone(6), upgradeReadyForReset(7), upgradeObsolete(8)  

ShePhysCardControlRequestType  
The card control request type (user command).
TEXTUAL-CONVENTION    
  INTEGER createCard(1), deleteCard(2), convertCard(3), changeAdminState(4), resetSystem(6), resetSystemWithDefault(7), resetCard(8), resetCardsAllOfType(9), changeAlarmSeverityProfile(10), setTemperatureThreshold(11)  

ShePhysCardControlRequestResultType  
The card control request result type, set after command completed or started.
TEXTUAL-CONVENTION    
  INTEGER commExecStarted(30), paramFaulty(31), requestBusy(32), setDataFailed(34), aswTimeout(35), commandFailed(36), commandSucceeded(37), upgradeRunning(40), resetRunning(41), cardNotAvail(42), resetNotSupported(43), resetNotSupportedOnStandbyBoard(44)  

ShePhysAdminStateChangeType  
The admin state type for changeAdminState command.
TEXTUAL-CONVENTION    
  INTEGER unlocked(1), locked(2), planned(4)  

ShePhysAdminStateCreateType  
The admin state type for createCard command.
TEXTUAL-CONVENTION    
  INTEGER locked(2), planned(4)  

ShePhysControlRequestType  
The rack/shelf control request type (user command).
TEXTUAL-CONVENTION    
  INTEGER changeAlarmSeverityProfile(2), changeShelfExternalAlarmSettings(3), changeShelfExternalAlarmOutputStatus(4), changeTemperatureWarningThreshold(5), changeShelfRelativeHumidityAlarmThreshold(6), changeShelfBatteryBackupMode(10)  

ShePhysPortControlRequestType  
The port control request type (user command).
TEXTUAL-CONVENTION    
  INTEGER changeAdminState(1), changeAlarmSeverityProfile(2), resetStatisticCounters(3), changeUserLabel(4), changeOperStateTrapEnablePermission(5)  

ShePhysPortControlRequestResultType  
The port control request result type, set after command completed or started.
TEXTUAL-CONVENTION    
  INTEGER commExecStarted(30), paramFaulty(31), requestBusy(32), setDataFailed(34), aswTimeout(35), commandFailed(36), commandSucceeded(37), singlePortNotAvailIfBonded(41)  

ShePhysBrdControlRequestType  
The type for redundancy enabling/disabling and switchOver commands. Modify redundancy feature for CXU.
TEXTUAL-CONVENTION    
  INTEGER enableBoardRedundancy(1), disableBoardRedundancy(2), switchOver(3), switchOverForced(4), modifyRedundancyFeature(5), modifyRedundancyInterlink(6)  

ShePhysBrdControlRequestResultType  
The type of rejest result after redundancy enabling/disabling or switchOver commands.
TEXTUAL-CONVENTION    
  INTEGER commExecStarted(30), paramFaulty(31), requestBusy(32), setDataFailed(34), aswTimeout(35), commandFailed(36), commandSucceeded(37), brdObjNotAvail(41), brdBoardNotInWorkingSlot(45), brdUpgradeRunningOnBoardInProtection(48), redundancyDisabled(52), boardSwitchOverForcedOnly(54), brdWrongEntPhysicalIndex(56), brdNoRedundancyAvailable(57)  

ShePhysControlRequestResultType  
The rack/shelf control request result type, set after command completed or started.
TEXTUAL-CONVENTION    
  INTEGER commExecStarted(30), paramFaulty(31), requestBusy(32), setDataFailed(34), aswTimeout(35), commandFailed(36), commandSucceeded(37)  

ShePhysShelfExternalAlarmOutputStatusType  
Used for alarmOutPutStatus and setting.
TEXTUAL-CONVENTION    
  INTEGER notActive(0), active(1)  

ShePhysShelfExternalAlarmLevelType  
Used for configuration of alarmInputLevels.
TEXTUAL-CONVENTION    
  INTEGER activeLow(0), activeHigh(1)  

ShePhysRedundancyFeatureType  
Used for configuration of redundancy feature.
TEXTUAL-CONVENTION    
  INTEGER noOpticalSplitter(0), useOpticalSplitter(1)  

ShePhysRedundancyInterlinkType  
Used for configuration of interlink types in case of redundancy.
TEXTUAL-CONVENTION    
  INTEGER disable(0), electrical(1), optical(2)  

ShePhysContainerEntry  
SEQUENCE    
  shePhysContainerAccCardTypes OCTET STRING
  shePhysContainerSlotStatus ShePhysSlotStatusType
  shePhysContainerConfiguredCardType DisplayString
  shePhysContainerPluggedCardType DisplayString

ShePhysCardEntry  
SEQUENCE    
  shePhysCardAdminState ShePhysCardAdminStateType
  shePhysCardAvailState ShePhysAvailabilityStateType
  shePhysCardOperState ShePhysCardOperStateType
  shePhysCardProtCapability ShePhysProtectionCapabilityType
  shePhysCardProtMode ShePhysProtectionModeType
  shePhysCardProtDefaultRole ShePhysDefaultRoleType
  shePhysCardProtDynamicRole ShePhysDynamicRoleType
  shePhysCardProtGroupId INTEGER
  shePhysCardProtState ShePhysProtState
  shePhysCardAlarmSeverityIndex SheAlarmSevProfileIndex
  shePhysCardUpgradeState ShePhysUpgradeStateType
  shePhysCardSwRunningLoad OCTET STRING
  shePhysCardSwStoredLoad OCTET STRING
  shePhysCardTemperatureCurrent INTEGER

ShePhysPortEntry  
SEQUENCE    
  shePhysPortEntPhysicalIndex PhysicalIndex
  shePhysPortId INTEGER
  shePhysPortAlarmSeverityIndex SheAlarmSevProfileIndex
  shePhysPortUserLabel OCTET STRING
  shePhysPortAdminStateLastChangeTime Unsigned32
  shePhysPortOperStateUpLastChangeTime Unsigned32
  shePhysPortOperStateDownLastChangeTime Unsigned32

ShePhysRackEntry  
SEQUENCE    
  shePhysRackAlarmSeverityIndex SheAlarmSevProfileIndex

ShePhysShelfEntry  
SEQUENCE    
  shePhysShelfAlarmSeverityIndex SheAlarmSevProfileIndex
  shePhysShelfTypeCode DisplayString
  shePhysShelfExternalAlarmOutput01Status ShePhysShelfExternalAlarmOutputStatusType
  shePhysShelfExternalAlarmOutput01Usage OCTET STRING
  shePhysShelfExternalAlarmOutput02Status ShePhysShelfExternalAlarmOutputStatusType
  shePhysShelfExternalAlarmOutput02Usage OCTET STRING
  shePhysShelfExternalAlarmOutput03Status ShePhysShelfExternalAlarmOutputStatusType
  shePhysShelfExternalAlarmOutput03Usage OCTET STRING
  shePhysShelfExternalAlarm01Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm01Usage OCTET STRING
  shePhysShelfExternalAlarm02Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm02Usage OCTET STRING
  shePhysShelfExternalAlarm03Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm03Usage OCTET STRING
  shePhysShelfExternalAlarm04Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm04Usage OCTET STRING
  shePhysShelfExternalAlarm05Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm05Usage OCTET STRING
  shePhysShelfExternalAlarm06Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm06Usage OCTET STRING
  shePhysShelfExternalAlarm07Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm07Usage OCTET STRING
  shePhysShelfExternalAlarm08Level ShePhysShelfExternalAlarmLevelType
  shePhysShelfExternalAlarm08Usage OCTET STRING
  shePhysShelfRelativeHumidity Unsigned32
  shePhysShelfRelativeHumidityAlarmOn Unsigned32
  shePhysShelfRelativeHumidityAlarmOff Unsigned32
  shePhysShelfBatteryBackupOption TruthValue
  shePhysShelfBatteryBackupMode TruthValue

Defined Values

shePhysical 1.3.6.1.4.1.231.7.1.2.1.1
The MIB module for representing multiple logical entities for the SHE Equipment management.
MODULE-IDENTITY    

shePhysContainerObjects 1.3.6.1.4.1.231.7.1.2.1.1.1
OBJECT IDENTIFIER    

shePhysContainerTable 1.3.6.1.4.1.231.7.1.2.1.1.1.1
The container/slot table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ShePhysContainerEntry

shePhysContainerEntry 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1
Entry of the container table. The entries represent the slots of a SHE shelf
Status: current Access: not-accessible
OBJECT-TYPE    
  ShePhysContainerEntry  

shePhysContainerAccCardTypes 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.1
This attribute identifies the types of plug-in units to be accepted by this slot. The strings are separated by newline characters. That means CR LF. Valid strings are: emptyCardType Central cards (support depend on NE release and used shelf): CXUGE:4E:E CXUCGE:4E:E CXUB1GE:4E:E CXUB2GE:4:E CXUC2GE:4:E CXUB3GE:4:E CXUB21GE:4:E CXUG1B:2O:4E:E (>=3.7M) DSL IU card's (support depend on used NE release): IUSHDSL:48S:E IUSHDSL:48B:E IUADSL:48P:E IUADSL:72A:E IUADSL:72B:E (obsolete) IUADSL:72P:IFX IUADSL:72I:IFX IUADSL:72AI:WC IUADSL:72AJ:WC IUVDSL:24D:IFX IUVDSL:24D2:IFX IUADSL:72A:CG IUADSL:72B:CG IUVDSL:24P:E IUVDSL:48P:E IUVDSL:48I:E (obsolete) IUADSL:72A:CGH IUADSL:72B:CGH IUADSL:72J:CGH IUSHDSL:48E:E IUSHDSL:48E:8Q:E (>=R2.8 maintenance) IUVDSL:48I2:E (>=R2.8) IUVDSL:48P2:E (>=R2.8) IUSHDSL:48E:ME:E (>=R3.7M) IUADSL:72B:M:CG (>=R3.7M) IUADSL:72B:ME:CG (>=R3.7M) IUADSL:72J:ME:CG (>=R3.7M) IUVDSL:48I3:M:E (>=R3.7M) IUVDSL:48I3:ME:E (>=R3.7M) IUVDSL:48J3:ME:E (>=R3.7M) Subtending card (with R3.7M also used as UNI card): IU1GE:10O:SYN:E VoIP-Cards (only supported if NE support VoIP at all): VPLU-S72-POTS:E IU:32I4:E IU:32I2:E VPLU:72P:E VPLU:72P1:E (>=R2.8M) VPLU:72P2:E (>=R2.8M) Powermodules (support depend on NE release and used shelf): PM1:E PM2:E PM3:A PM:UPL:E PM:UPL:R:E PM:UPL:A PM1:R:E PM1:R:A PM:R:A Powermodules for new shelftypes 2. generation -> 2G (>= R2.8 maintenance): PM:UPL:2G:E PM:UPL:2G:A PM1:R:2G:E PM:R:2G:E PM:R:2G:A PM:ONU:2G:E Boards for hiX5622 R1.0: (obsolete because release was canceled) CXUMGE:4:E SBXDSL:16P:E SBXDSL:16:E Board for hiX5608 (MiniIPD): HIX5608:E
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..350)  

shePhysContainerSlotStatus 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.4
Indicates whether a slot is empty or used.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysSlotStatusType  

shePhysContainerConfiguredCardType 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.5
This attribute identifies the card type configured for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

shePhysContainerPluggedCardType 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.6
This attribute identifies the card type plugged for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

shePhysCardObjects 1.3.6.1.4.1.231.7.1.2.1.1.2
OBJECT IDENTIFIER    

shePhysCardTable 1.3.6.1.4.1.231.7.1.2.1.1.2.1
Table containing the plug-in unit entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ShePhysCardEntry

shePhysCardEntry 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1
Entry of shePhysCardTable. Each entry is used to represent a card independently whether it is present or not (feature offline configuration). Cards can be created either by auto-configuration (plug-in) or by user command. Notifications : shePhysStateChangeOper. shePhysStateChangeAdmin. shePhysCardCreated. shePhysCardDeleted. Alarm traps when a fault has been detected or cleared.
Status: current Access: not-accessible
OBJECT-TYPE    
  ShePhysCardEntry  

shePhysCardAdminState 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.1
This attribute shows the administrative state of the plugin unit. In the transition from lock to unlock the plug-in unit is diagnosed. Default is notEquipped except for controller cards. The AdminState of controller cards is always unlocked. Planned is very similar to the locked state. Planned is used for configuration of cards without having a card equipped. A correct card being plugged leads to an auto-configuration of the card: the AdminState changes automatically from planned to unlocked.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysCardAdminStateType  

shePhysCardAvailState 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.2
The availability state of a card.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysAvailabilityStateType  

shePhysCardOperState 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.3
The operational state of a card.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysCardOperStateType  

shePhysCardProtCapability 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.4
The protection modes the card can work: -bit0=1: Card can work as standalone card. -bit1=1: Card can work as standby card.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysProtectionCapabilityType  

shePhysCardProtMode 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.5
The redundancy mode the card is running. -standaloneCard: The card works as standalone board. No redundancy is supported. -protectionCard: The card works in redundancy mode.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysProtectionModeType  

shePhysCardProtDefaultRole 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.6
Defines the default role of the card (e.g. after power on) if more than one card which belong to the same protection group are become availible at the same time. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. -working: The card becomes the active card by default. -protecting: The card becomes the standby card by default.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysDefaultRoleType  

shePhysCardProtDynamicRole 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.7
The dynamic role of card. Note, this attribute is only valid if shePhysCardProtMode = protectionCard. -active: The card is the active card. -standby: The card is the standby card. -notDefined: If there is no card plugged, it is not possible to say which card will become the active or standby card.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysDynamicRoleType  

shePhysCardProtGroupId 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.8
The ID of protection group this card belongs to. Cards with the same Id can protect each other. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

shePhysCardProtState 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.9
The current state of the protection: -unknown If the dynamic role of the cards which belong to a protection group is not set yet, there is no information about the protection state available. -active_noRedundancy: The card is the active card but is not protected by a standby card. -active_protected: The card is the active card is is protected by a standby card. -active_degraded: The card is the active card but not all functionality is protected by the standby card. -standby_notPresent: The card is the standby card but it is not available. -standby_booting: The card is the standby card but is still booting. -standby_protecting: The card is the standby card and protects the active card. -standby_degraded: The card is the standby card but can not take over all functionality of the current active board. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysProtState  

shePhysCardAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.10
It is a pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.
Status: current Access: read-only
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

shePhysCardUpgradeState 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.11
Informs about the state of the SW upgrade task during loading and the result at the end of loading the current plug-in unit. NOTE: The parameter is set to obsolete state with R3.7M. Also former releases does not report a valid information on this parameter. Valid informations about SW upgrade could only be retrieved via sheSystemSwMaintenanceTaskTable.
Status: obsolete Access: read-only
OBJECT-TYPE    
  ShePhysUpgradeStateType  

shePhysCardSwRunningLoad 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.12
Informs about the currently running load.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

shePhysCardSwStoredLoad 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.13
Informs about the currently stored load.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

shePhysCardTemperatureCurrent 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.14
Current temperature of a card - 255 means unknown value.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -40..200 | 255  

shePhysCardControl 1.3.6.1.4.1.231.7.1.2.1.1.2.2
OBJECT IDENTIFIER    

shePhysCardControlRequest 1.3.6.1.4.1.231.7.1.2.1.1.2.2.1
The card commands : changeAdminState: changes the shePhysCardAdminState of a card. AdminState of controller cards cannot be changed. changeAlarmSeverityProfile: changes the shePhysCardAlarmSeverityIndex of a card. This is the pointer to a alarm severity profile. createCard: creates plugin units. Acceptable in state NotEquipped and when object does not exist. The AdminState after creation, possible values are Planned or Locked, is specified as command parameter. The command is not accepted for CXUs. These HW objects are automatically created. The acceptable CardTypes are specified in the slot attribute shePhysContainerAccCardTypes. The content of this attribute changes after the creation to values allowed for the convert command. deleteCard: deletes a card. Acceptable only in state Planned/Locked. The command is not accepted for CXUs. CXUs are automatically deleted when board redundancy is disabled. The AdminState changes to NotEquipped. convertCard: converts the type of card. Acceptable only within the same card group, e.g. ADSL to ADSL according to content of types listed in shePhysContainerAccCardTypes. convertCard allowed in state Planned/Locked. Notifications: shePhysCardControlResult when a command has finished. reset commands: resetSystem: reset of system (all cards) and activates loads after SW download. The main card will perform a restart. resetSystemWithDefaultConf : restart with default configuration is performed. resetCard: after SW download to activate the new load of a specific card. resetCardAllOfType: after SW download of cards of the same type to activate the new load. Notifications : shePhysCardReset at beginning of reset. shePhysCardResetEnd at end of reset. shePhysCardControlResult for reset of CXU in case of a failure occured after the reset has been accepted. changeAlarmSeverityProfile: the alarm severity profile is changed for a specific card. THIS REQUEST WILL NOT LONGER BE SUPPORTED BY NE R2.5: setTemperatureThreshold: configure the temperature threshold which is used. When temperature reaches the threshold, alarm is turned on.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysCardControlRequestType  

shePhysCardControlStatus 1.3.6.1.4.1.231.7.1.2.1.1.2.2.2
The status of a user command.
Status: current Access: read-only
OBJECT-TYPE    
  SheControlStatusType  

shePhysCardControlPhysicalName 1.3.6.1.4.1.231.7.1.2.1.1.2.2.3
A valid string for a card. Identifies the type of card which should be created. Default is .
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString  

shePhysCardControlContainedInIndex 1.3.6.1.4.1.231.7.1.2.1.1.2.2.4
The entPhysicalIndex of the slot which contains the card.
Status: current Access: read-write
OBJECT-TYPE    
  PhysicalIndex  

shePhysCardControlTimer 1.3.6.1.4.1.231.7.1.2.1.1.2.2.5
The maximum wait time for the manager for a long running user command.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysCardControlReqResult 1.3.6.1.4.1.231.7.1.2.1.1.2.2.6
The result of the last user command.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysCardControlRequestResultType  

shePhysCardControlTimeStamp 1.3.6.1.4.1.231.7.1.2.1.1.2.2.7
The time stamp of the last command (end of command).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysCardControlAdminStateChange 1.3.6.1.4.1.231.7.1.2.1.1.2.2.8
Selects the desired adminstrative state.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysAdminStateChangeType  

shePhysCardControlAdminStateCreate 1.3.6.1.4.1.231.7.1.2.1.1.2.2.9
Selects the desired adminstrative state in user command createCard.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysAdminStateCreateType  

shePhysCardControlTemperatureThreshold 1.3.6.1.4.1.231.7.1.2.1.1.2.2.10
The temperature threshold for all cards. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER -40..200  

shePhysCardControlEntPhysicalIndex 1.3.6.1.4.1.231.7.1.2.1.1.2.2.13
The entPhysicalIndex of the plugin unit which should get the reset.
Status: current Access: read-write
OBJECT-TYPE    
  PhysicalIndex  

shePhysCardControlAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.2.2.14
The new AlarmSeverityIndex of the alarm severity profile assigned to the card.
Status: current Access: read-write
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

sheTemperatureObjects 1.3.6.1.4.1.231.7.1.2.1.1.2.3
OBJECT IDENTIFIER    

shePhysCardTemperaturePowerDownOn 1.3.6.1.4.1.231.7.1.2.1.1.2.3.1
Temperature threshold for generation of shePhysCardTemperaturePowerDown alarm for line cards. IU will start now with action to reduce power consumption.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..120  

shePhysCardTemperaturePowerDownOff 1.3.6.1.4.1.231.7.1.2.1.1.2.3.2
Temperature threshold for clearing of shePhysCardOverTemperatureReset alarm for the line cards.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..120  

shePhysCardOverTemperatureResetOn 1.3.6.1.4.1.231.7.1.2.1.1.2.3.3
Temperature threshold for the generation of the shePhysCardOverTemperatureReset alarm for line cards. CXU has forced IU tp reset state, to prevend from further damages.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..120  

shePhysCardOverTemperatureResetOff 1.3.6.1.4.1.231.7.1.2.1.1.2.3.4
Temperature threshold for the clearing the shePhysCardOverTemperatureReset alarm for line cards.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..120  

shePhysCardTemperatureThreshold 1.3.6.1.4.1.231.7.1.2.1.1.2.3.5
THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. Temperature threshold for all cards of shePhysCardOverTemperatureThreshold.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Integer32 -40..200  

shePhysCardTemperatureWarningOn 1.3.6.1.4.1.231.7.1.2.1.1.2.3.6
Temperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -40..120  

shePhysCardTemperatureWarningOff 1.3.6.1.4.1.231.7.1.2.1.1.2.3.7
Temperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -40..120  

sheTemperatureControlObjects 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10
OBJECT IDENTIFIER    

shePhysCardTemperatureControlRequest 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.1
The card commands : changeTemperatureWarningThreshold: changes the shePhysCardTemperatureWarningThreshold's.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysControlRequestType  

shePhysCardTemperatureControlStatus 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.2
The status of a user command.
Status: current Access: read-only
OBJECT-TYPE    
  SheControlStatusType  

shePhysCardTemperatureControlTimer 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.3
The maximum wait time for the manager for a long running user command.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysCardTemperatureControlReqResult 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.4
The result of the last user command.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysCardControlRequestResultType  

shePhysCardTemperatureControlTimeStamp 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.5
The time stamp of the last command (end of command).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysCardTemperatureControlWarningOn 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.6
Temperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -40..120  

shePhysCardTemperatureControlWarningOff 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.7
Temperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -40..120  

shePhysPortObjects 1.3.6.1.4.1.231.7.1.2.1.1.3
OBJECT IDENTIFIER    

shePhysPortTable 1.3.6.1.4.1.231.7.1.2.1.1.3.1
The port table extension of the IfTable. Provides the mapping information concerning port and card the port is contained and the alarm severity profile.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ShePhysPortEntry

shePhysPortEntry 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1
Entry of the port table. Represents a physical interface (a port).
Status: current Access: not-accessible
OBJECT-TYPE    
  ShePhysPortEntry  

shePhysPortEntPhysicalIndex 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.1
The entPhysical index of the card this port is contained in.
Status: current Access: read-only
OBJECT-TYPE    
  PhysicalIndex  

shePhysPortId 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.2
The port number/port ID related to the card this port is contained in.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

shePhysPortAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.3
A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.
Status: current Access: read-only
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

shePhysPortUserLabel 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.4
Port specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..200)  

shePhysPortAdminStateLastChangeTime 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.5
The timestamp when this port last times changes adminstate. New parameter with SHE R2.8 maintenance.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortOperStateUpLastChangeTime 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.6
The timestamp when this port last times reaches operstate UP. New parameter with SHE R2.8 maintenance.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortOperStateDownLastChangeTime 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.7
The timestamp when this port last times reaches operstate DOWN. New parameter with SHE R2.8 maintenance.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortControl 1.3.6.1.4.1.231.7.1.2.1.1.3.2
OBJECT IDENTIFIER    

shePhysPortControlRequest 1.3.6.1.4.1.231.7.1.2.1.1.3.2.1
The port commands : changeAdminState: the AdminState of the current port shall be changed. changeAlarmSeverityProfile: the alarm severity profile of the port is changed. resetStatisticCounters: reset all statistic counters in if- and ifx-table for this port. changeUserLabel: change the value of the UserLabel for this port. changeOperStateTrapEnablePermission: change the permission to send operstate trap for this port. Notifications : shePhysPortControlResult at the command ending in case of long running command.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysPortControlRequestType  

shePhysPortControlStatus 1.3.6.1.4.1.231.7.1.2.1.1.3.2.2
The status of a user command.
Status: current Access: read-only
OBJECT-TYPE    
  SheControlStatusType  

shePhysPortControlIfIndex 1.3.6.1.4.1.231.7.1.2.1.1.3.2.3
The IfIndex of the port that shall be configured.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

shePhysPortControlAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.3.2.4
The new AlarmSeverityIndex of the alarm severity profile assigned to the port.
Status: current Access: read-write
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

shePhysPortControlAdminState 1.3.6.1.4.1.231.7.1.2.1.1.3.2.5
The desired AdminState of the port that shall be configured.
Status: current Access: read-write
OBJECT-TYPE    
  SheAdminStateType  

shePhysPortControlTimeStamp 1.3.6.1.4.1.231.7.1.2.1.1.3.2.6
The time stamp of the last command (end of command).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortControlTimer 1.3.6.1.4.1.231.7.1.2.1.1.3.2.7
The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult .
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortControlReqResult 1.3.6.1.4.1.231.7.1.2.1.1.3.2.8
The result of the last user command.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysPortControlRequestResultType  

shePhysPortControlUserLabel 1.3.6.1.4.1.231.7.1.2.1.1.3.2.9
Port specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..200)  

shePhysPortControlOperStateTrapEnable 1.3.6.1.4.1.231.7.1.2.1.1.3.2.10
Enable/disable OperStateTrap's. Current status could be read from ifx-table.
Status: current Access: read-write
OBJECT-TYPE    
  ShePermissionType  

shePhysPortNEInfo 1.3.6.1.4.1.231.7.1.2.1.1.3.3
OBJECT IDENTIFIER    

shePhysPortAdslCount 1.3.6.1.4.1.231.7.1.2.1.1.3.3.1
This attribute returns the current number of available physical port's of type ADSL (ifType 94) of the NE. The attribute could be used by the management system for licensing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortShdslCount 1.3.6.1.4.1.231.7.1.2.1.1.3.3.2
This attribute returns the current number of available physical port's of type SHDSL (ifType 96) of the NE. The attribute could be used by the management system for licensing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortVdslCount 1.3.6.1.4.1.231.7.1.2.1.1.3.3.3
This attribute returns the current number of available physical port's of type VDSL (ifType 97) of the NE. The attribute could be used by the management system for licensing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortAdsl2Count 1.3.6.1.4.1.231.7.1.2.1.1.3.3.4
This attribute returns the current number of available physical port's of type ADSL2 (ifType 230) of the NE. The attribute could be used by the management system for licensing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortVoipCount 1.3.6.1.4.1.231.7.1.2.1.1.3.3.5
This attribute returns the current number of available physical port's of type VOIP (ifType 104) of the NE. The attribute could be used by the management system for licensing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysPortIsdnCount 1.3.6.1.4.1.231.7.1.2.1.1.3.3.6
This attribute returns the current number of available physical port's of type ISDN (ifType 63) of the NE. The attribute could be used by the management system for licensing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysRedundancyObjects 1.3.6.1.4.1.231.7.1.2.1.1.4
OBJECT IDENTIFIER    

shePhysBoardRedundancyControl 1.3.6.1.4.1.231.7.1.2.1.1.4.1
OBJECT IDENTIFIER    

shePhysBrdControlRequest 1.3.6.1.4.1.231.7.1.2.1.1.4.1.1
The user commands for board redundancy and switch over. enableBoardRedundancy, disableBoardRedundancy: to enable/disable board redundancy. boardSwitchOver: applicable when board redundancy is enabled and the standby board is in the state ShePhysCardProtState = standby_protecting (There is no traffic interruption in case of swithover.) boardSwitchOverForced: applicable when board redundancy is enabled, ShePhysCardProtState = standby_protecting or standby_degraded. modifyRedundancyFeature: applicable only for CXU-board modifyRedundancyInterlinksFeature: applicable only for CXU-board
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysBrdControlRequestType  

shePhysBrdControlStatus 1.3.6.1.4.1.231.7.1.2.1.1.4.1.2
The status of the control request.
Status: current Access: read-only
OBJECT-TYPE    
  SheControlStatusType  

shePhysBrdControlReqResult 1.3.6.1.4.1.231.7.1.2.1.1.4.1.3
The result of the last user command.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysBrdControlRequestResultType  

shePhysBrdControlTimeStamp 1.3.6.1.4.1.231.7.1.2.1.1.4.1.4
The time stamp of the last command (end of command).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysBrdControlTimer 1.3.6.1.4.1.231.7.1.2.1.1.4.1.5
The maximum wait time for the manager for a line redundancy user command.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysBrdControlEntPhysicalIndex 1.3.6.1.4.1.231.7.1.2.1.1.4.1.6
The entPhysicalIndex of the card to be switched over or modified.
Status: current Access: read-write
OBJECT-TYPE    
  PhysicalIndex  

shePhysBrdControlRedundancyFeature 1.3.6.1.4.1.231.7.1.2.1.1.4.1.7
Only applicable for CXU-board.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysRedundancyFeatureType  


shePhysRedundancyBase 1.3.6.1.4.1.231.7.1.2.1.1.4.2
OBJECT IDENTIFIER    

shePhysRedundancyFeature 1.3.6.1.4.1.231.7.1.2.1.1.4.2.1
Configure special features they are importend for redundancy handling.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysRedundancyFeatureType  


shePhysicalNotifications 1.3.6.1.4.1.231.7.1.2.1.1.5
OBJECT IDENTIFIER    

shePhysRackEvents 1.3.6.1.4.1.231.7.1.2.1.1.5.1
OBJECT IDENTIFIER    

shePhysRackControlResult 1.3.6.1.4.1.231.7.1.2.1.1.5.1.1
Notification of rack command ending and result.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysRackAlarms 1.3.6.1.4.1.231.7.1.2.1.1.5.2
OBJECT IDENTIFIER    

shePhysDCAlarm0 1.3.6.1.4.1.231.7.1.2.1.1.5.2.1
Break down of power supply fan group 0 .
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysDCAlarm1 1.3.6.1.4.1.231.7.1.2.1.1.5.2.2
Break down of power supply fan group 1 .
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysFanAlarm0 1.3.6.1.4.1.231.7.1.2.1.1.5.2.3
Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 0. G100 G200 G400, G600, M1100, G1100: -> Fan control defective.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysFanAlarm1 1.3.6.1.4.1.231.7.1.2.1.1.5.2.4
Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 1. G100 G200 G400, G600, M1100, G1100: -> Fan defective (Sum alarm).
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysFanAlarm2 1.3.6.1.4.1.231.7.1.2.1.1.5.2.5
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 2. G100 G200 G400, G600, M1100, G1100: -> Filter pad must be cleaned. MDUS: -> not used.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysFanAlarm3 1.3.6.1.4.1.231.7.1.2.1.1.5.2.6
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 3. G100 G200 G400, G600, M1100, G1100, MDUS: -> not used
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysFanAlarm4 1.3.6.1.4.1.231.7.1.2.1.1.5.2.7
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysFanAlarm5 1.3.6.1.4.1.231.7.1.2.1.1.5.2.8
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfEvents 1.3.6.1.4.1.231.7.1.2.1.1.5.3
OBJECT IDENTIFIER    

shePhysShelfControlResult 1.3.6.1.4.1.231.7.1.2.1.1.5.3.1
Notification of chassis command ending and result.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfControlExternalAlarmsConfigurationChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.3.2
External alarm configuration changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfControlRelativeHumidityAlarmThresholdChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.3.3
Alarm threshold configuration changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfBatteryBackupModified 1.3.6.1.4.1.231.7.1.2.1.1.5.3.4
Could only occur in shelf SHE hiX5622 R1.0 -> MDUS:E, if battery backupMode was modified.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfControlExternalAlarmsOutputStatusChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.3.5
External alarm output status configuration changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfAlarms 1.3.6.1.4.1.231.7.1.2.1.1.5.4
OBJECT IDENTIFIER    

shePhysShelfMupState1 1.3.6.1.4.1.231.7.1.2.1.1.5.4.1
Break down of redundancy power supply 1 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfMupState2 1.3.6.1.4.1.231.7.1.2.1.1.5.4.2
Break down of redundancy power supply 2 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm01 1.3.6.1.4.1.231.7.1.2.1.1.5.4.3
External Alarm 01. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm02 1.3.6.1.4.1.231.7.1.2.1.1.5.4.4
External Alarm 2. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm03 1.3.6.1.4.1.231.7.1.2.1.1.5.4.5
External Alarm 3. Default usage in hix5622 system R1.0 (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm04 1.3.6.1.4.1.231.7.1.2.1.1.5.4.6
External Alarm 4. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm05 1.3.6.1.4.1.231.7.1.2.1.1.5.4.7
External Alarm 5. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm06 1.3.6.1.4.1.231.7.1.2.1.1.5.4.8
External Alarm 6. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm07 1.3.6.1.4.1.231.7.1.2.1.1.5.4.9
External Alarm 7.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExternalAlarm08 1.3.6.1.4.1.231.7.1.2.1.1.5.4.10
External Alarm 8.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfRelativeHumidityAlarm 1.3.6.1.4.1.231.7.1.2.1.1.5.4.11
The configured threshold for relative humidity was reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfHeatExchangerIn 1.3.6.1.4.1.231.7.1.2.1.1.5.4.12
Break down of 1 or more fan of the heat exchanger inner circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfHeatExchangerOut 1.3.6.1.4.1.231.7.1.2.1.1.5.4.13
Break down of 1 or more fan of the heat exchanger outer circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysShelfExtAlarmCollectorNotConnected 1.3.6.1.4.1.231.7.1.2.1.1.5.4.14
External Alarm Collector is not connected. The detection of external Alarms is not possible. Only valid if powermodule PM:ONU:2G:E is used.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardEvents 1.3.6.1.4.1.231.7.1.2.1.1.5.5
OBJECT IDENTIFIER    

shePhysCardControlResult 1.3.6.1.4.1.231.7.1.2.1.1.5.5.1
Notification sent end of a long running card command.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardAdminStateChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.5.2
The card's adminState changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardStateChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.5.3
The card's operational/availabilty state changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardReset 1.3.6.1.4.1.231.7.1.2.1.1.5.5.4
Card is performing a reset.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardResetEnd 1.3.6.1.4.1.231.7.1.2.1.1.5.5.5
End of card reset.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardCreated 1.3.6.1.4.1.231.7.1.2.1.1.5.5.6
Card created.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardDeleted 1.3.6.1.4.1.231.7.1.2.1.1.5.5.7
Card deleted.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardDeletionStarted 1.3.6.1.4.1.231.7.1.2.1.1.5.5.8
The card deletion procedure in the NE was started.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysContainerCardTypeConverted 1.3.6.1.4.1.231.7.1.2.1.1.5.5.9
Card type converted.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardConvertionStarted 1.3.6.1.4.1.231.7.1.2.1.1.5.5.10
The card convertion procedure in the NE was started.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardPlugged 1.3.6.1.4.1.231.7.1.2.1.1.5.5.11
A card was plugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged and the second, the entPhysicalIndex of the card itself.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardUnplugged 1.3.6.1.4.1.231.7.1.2.1.1.5.5.12
A card was unplugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged before and the second, the entPhysicalIndex of the card itself.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardChangedTemperatureThreshold 1.3.6.1.4.1.231.7.1.2.1.1.5.5.13
The temperature threshold has been configured. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5.
Status: obsolete Access: read-only
NOTIFICATION-TYPE    

shePhysCardTemperatureWarningThresholdsChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.5.14
Configuration event.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardAlarms 1.3.6.1.4.1.231.7.1.2.1.1.5.6
OBJECT IDENTIFIER    

shePhysCardTypeMismatch 1.3.6.1.4.1.231.7.1.2.1.1.5.6.1
Wrong card is plugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardFailure 1.3.6.1.4.1.231.7.1.2.1.1.5.6.2
Card out of service.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardProblem 1.3.6.1.4.1.231.7.1.2.1.1.5.6.3
Card partly out of service.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardNotInstalled 1.3.6.1.4.1.231.7.1.2.1.1.5.6.4
Card not plugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardTemperaturePowerDown 1.3.6.1.4.1.231.7.1.2.1.1.5.6.5
Temperature alarm. The IU has detect high temperature and start's first action to reduce power consumption.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardOverTemperatureReset 1.3.6.1.4.1.231.7.1.2.1.1.5.6.6
CXU has forced IU-Card to reset because of over temperature.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardOverTemperatureThreshold 1.3.6.1.4.1.231.7.1.2.1.1.5.6.7
Card temperature Threshold alarm. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardTemperatureWarning 1.3.6.1.4.1.231.7.1.2.1.1.5.6.8
Temperature warning alarm. The CXU has detected a higher temperature then the configured value.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysCardSWVersionProblem 1.3.6.1.4.1.231.7.1.2.1.1.5.6.9
Card out of service due to wrong SW version. Please upgrade!
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysPortEvents 1.3.6.1.4.1.231.7.1.2.1.1.5.7
OBJECT IDENTIFIER    

shePhysPortAdminStateChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.7.1
The port's adminState changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifAdminState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifAdminStates of all port's.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysPortOperStateChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.7.2
The port's operational state changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifOperState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifOperStates of all port's.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysPortControlResult 1.3.6.1.4.1.231.7.1.2.1.1.5.7.3
Notification of port command ending and result.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysPortCreated 1.3.6.1.4.1.231.7.1.2.1.1.5.7.4
Notification about port creation. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card creation sequence, normaly a large number of PortCreated-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all created port's for the entPhysicalIndex of this new card.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysPortDeleted 1.3.6.1.4.1.231.7.1.2.1.1.5.7.5
Notification about the succesfull delete of a port. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card deletion sequence, normaly a large number of PortDeleted-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all deleted port's for the entPhysicalIndex of this card.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysPortAlarms 1.3.6.1.4.1.231.7.1.2.1.1.5.8
OBJECT IDENTIFIER    

shePhysPortOperStateDown 1.3.6.1.4.1.231.7.1.2.1.1.5.8.1
This is a operstate-down alarm trap. This trap could not be send as collection trap (different from OperStateChanged - Event trap)!! This trap could be blocked by setting in alarmseverity-profile.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysRedundancyEvents 1.3.6.1.4.1.231.7.1.2.1.1.5.9
OBJECT IDENTIFIER    

shePhysBrdControlResult 1.3.6.1.4.1.231.7.1.2.1.1.5.9.1
Notification of board redundancy command ending and result.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysRedundancyStateChanged 1.3.6.1.4.1.231.7.1.2.1.1.5.9.2
Notification of change of redundancy ralated attributes of a card.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysRedundancyFeatureModified 1.3.6.1.4.1.231.7.1.2.1.1.5.9.3
Modification response trap.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysRedundancyInterlinkModified 1.3.6.1.4.1.231.7.1.2.1.1.5.9.4
The medium type for interlink has been changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysRedundancyAlarms 1.3.6.1.4.1.231.7.1.2.1.1.5.10
OBJECT IDENTIFIER    

shePhysRedundancyNoRedundancy 1.3.6.1.4.1.231.7.1.2.1.1.5.10.1
Redundancy is not available for a card.
Status: current Access: read-only
NOTIFICATION-TYPE    

shePhysRackObjects 1.3.6.1.4.1.231.7.1.2.1.1.6
OBJECT IDENTIFIER    

shePhysRackTable 1.3.6.1.4.1.231.7.1.2.1.1.6.1
The shelf/chassis table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ShePhysRackEntry

shePhysRackEntry 1.3.6.1.4.1.231.7.1.2.1.1.6.1.1
Entry of the rack table. The entries represent the SHE rack.
Status: current Access: not-accessible
OBJECT-TYPE    
  ShePhysRackEntry  

shePhysRackAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.6.1.1.1
A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.
Status: current Access: read-only
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

shePhysRackControl 1.3.6.1.4.1.231.7.1.2.1.1.6.2
OBJECT IDENTIFIER    

shePhysRackControlRequest 1.3.6.1.4.1.231.7.1.2.1.1.6.2.1
The rack commands : changeAlarmSeverityProfile: the alarm severity profile of the rack is changed. Notifications : shePhysRackControlResult at the command ending in case of long running command.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysControlRequestType  

shePhysRackControlStatus 1.3.6.1.4.1.231.7.1.2.1.1.6.2.2
The status of a user command.
Status: current Access: read-only
OBJECT-TYPE    
  SheControlStatusType  

shePhysRackControlIndex 1.3.6.1.4.1.231.7.1.2.1.1.6.2.3
The entPhysicalIndex of the rack.
Status: current Access: read-write
OBJECT-TYPE    
  PhysicalIndex  

shePhysRackControlAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.6.2.4
The new AlarmSeverityIndex of the alarm severity profile assigned to the rack.
Status: current Access: read-write
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

shePhysRackControlTimeStamp 1.3.6.1.4.1.231.7.1.2.1.1.6.2.5
The time stamp of the last command (end of command).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysRackControlTimer 1.3.6.1.4.1.231.7.1.2.1.1.6.2.6
The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysResult .
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysRackControlReqResult 1.3.6.1.4.1.231.7.1.2.1.1.6.2.7
The result of the last user command.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysControlRequestResultType  

shePhysShelfObjects 1.3.6.1.4.1.231.7.1.2.1.1.7
OBJECT IDENTIFIER    

shePhysShelfTable 1.3.6.1.4.1.231.7.1.2.1.1.7.1
The shelf/chassis table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ShePhysShelfEntry

shePhysShelfEntry 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1
Entry of the chassis table. The entries represent the SHE shelf(s).
Status: current Access: not-accessible
OBJECT-TYPE    
  ShePhysShelfEntry  

shePhysShelfAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.1
A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.
Status: current Access: read-only
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

shePhysShelfTypeCode 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.2
Contains the typecode for the possible used She-Shelf's. Depending on the detected shelftype-code the corresponding system version will be displayed. Systemversion -> Shelftypes SHE hiX5635 -> M1200:E, M1100:E, G1100:E, G1100:A, G1100:B:E SHE hiX5630 -> M600:E, G600:E, G600:R:E, M600:DF:E SHE hiX5625 -> M400:E, G400:E, G400:R:A, SHE hiX5622 R1.0 -> MDUS:E (obsolete because release was canceled) SHE hiX5608 -> 'empty' string because no shelf is used, single box system Shelftype's 2 generation - only new 2G powermodules could be used! (>= with R2.8 maintenance) SHE hiX5635 -> G1100:2G:E, M1100:2G:E SHE hiX5630 -> G600:2G:E, G600:R:2G:E, SHE hiX5625 -> G400:2G:E, G400:R:2G:E, SHE hiX5622 -> G200:2G:E, G200S:2G:E
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

shePhysShelfExternalAlarmOutput01Status 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.3
Status of the external alarm output 01.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmOutputStatusType  

shePhysShelfExternalAlarmOutput01Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.4
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarmOutput02Status 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.5
Status of the external alarm output 02.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmOutputStatusType  

shePhysShelfExternalAlarmOutput02Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.6
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarmOutput03Status 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.7
Status of the external alarm output 03.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmOutputStatusType  

shePhysShelfExternalAlarmOutput03Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.8
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm01Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.9
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm01Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.10
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hiX5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power Default usage in hiX5608 R1.0 system: Door Contact -> Physical Intrusion alarm.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm02Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.11
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm02Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.12
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm03Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.13
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm03Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.14
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm04Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.15
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm04Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.16
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm05Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.17
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm05Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.18
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm06Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.19
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm06Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.20
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm07Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.21
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm07Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.22
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfExternalAlarm08Level 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.23
Configured level for active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfExternalAlarm08Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.24
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfRelativeHumidity 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.25
Environmentale parameter for relative humidity in %. This parameter is only valid for shelftype G400R//G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. In all other cases the value 255 will report, that a valid measurement result is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..100 | 255  

shePhysShelfRelativeHumidityAlarmOn 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.26
Environmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..100  

shePhysShelfRelativeHumidityAlarmOff 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.27
Environmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..100  

shePhysShelfBatteryBackupOption 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.28
Indication wether the SHE supports battery backup. Only shelftype SHE hiX5622 R1.0 -> MDUS:E will support battery backup, otherwise false.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

shePhysShelfBatteryBackupMode 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.29
Indication wether battery backup is provisioned. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

shePhysShelfControl 1.3.6.1.4.1.231.7.1.2.1.1.7.2
OBJECT IDENTIFIER    

shePhysShelfControlRequest 1.3.6.1.4.1.231.7.1.2.1.1.7.2.1
The chassis commands : changeAlarmSeverityProfile: the alarm severity profile of the chassis is changed. changeShelfExternalAlarmSettings change level for active external alarms and set a descriptional name for usage Notifications : shePhysShelfControlExternalAlarmsConfigurationChanged shePhysShelfControlResult at the command ending in case of long running command. changeShelfRelativeHumidityAlarmThreshold change the alarm threshold configuration for environmental parameter relative humidity Notifications: shePhysShelfControlRelativeHumidityAlarmThresholdChanged hiX5622 R1.0 only: changeShelfBatteryBackupMode: shePhysShelfControlBatteryBackupMode Notifications: shePhysShelfBatteryBackupModified New with R2.8: changeShelfExternalAlarmOutputStatus change status external alarm outputs Notifications : shePhysShelfControlExternalAlarmsOutputStatusChanged
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysControlRequestType  

shePhysShelfControlStatus 1.3.6.1.4.1.231.7.1.2.1.1.7.2.2
The status of a user command.
Status: current Access: read-only
OBJECT-TYPE    
  SheControlStatusType  

shePhysShelfControlIndex 1.3.6.1.4.1.231.7.1.2.1.1.7.2.3
The entPhysicalIndex of the shelf.
Status: current Access: read-write
OBJECT-TYPE    
  PhysicalIndex  

shePhysShelfControlTimeStamp 1.3.6.1.4.1.231.7.1.2.1.1.7.2.4
The time stamp of the last command (end of command).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysShelfControlTimer 1.3.6.1.4.1.231.7.1.2.1.1.7.2.5
The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult .
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

shePhysShelfControlReqResult 1.3.6.1.4.1.231.7.1.2.1.1.7.2.6
The result of the last user command.
Status: current Access: read-only
OBJECT-TYPE    
  ShePhysControlRequestResultType  

shePhysShelfControlAlarmSeverityIndex 1.3.6.1.4.1.231.7.1.2.1.1.7.2.7
The new AlarmSeverityIndex of the alarm severity profile assigned to the chassis.
Status: current Access: read-write
OBJECT-TYPE    
  SheAlarmSevProfileIndex  

shePhysShelfControlExternalAlarmOutput01Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.8
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarmOutput02Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.9
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarmOutput03Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.10
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm01Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.11
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm01Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.12
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm02Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.13
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm02Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.14
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm03Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.15
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm03Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.16
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm04Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.17
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm04Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.18
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm05Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.19
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm05Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.20
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm06Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.21
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm06Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.22
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm07Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.23
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm07Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.24
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlExternalAlarm08Level 1.3.6.1.4.1.231.7.1.2.1.1.7.2.25
Configured level for active alarm.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmLevelType  

shePhysShelfControlExternalAlarm08Usage 1.3.6.1.4.1.231.7.1.2.1.1.7.2.26
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

shePhysShelfControlRelativeHumidityAlarmOn 1.3.6.1.4.1.231.7.1.2.1.1.7.2.27
Configure the environmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..100  

shePhysShelfControlRelativeHumidityAlarmOff 1.3.6.1.4.1.231.7.1.2.1.1.7.2.28
Configure the environmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..100  

shePhysShelfControlBatteryBackupMode 1.3.6.1.4.1.231.7.1.2.1.1.7.2.29
Provisioning of battery backup. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

shePhysShelfControlExternalAlarmOutput01Status 1.3.6.1.4.1.231.7.1.2.1.1.7.2.30
Set the status of the external alarm output 01.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmOutputStatusType  

shePhysShelfControlExternalAlarmOutput02Status 1.3.6.1.4.1.231.7.1.2.1.1.7.2.31
Set the status of the external alarm output 02.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmOutputStatusType  

shePhysShelfControlExternalAlarmOutput03Status 1.3.6.1.4.1.231.7.1.2.1.1.7.2.32
Set the status of the external alarm output 03.
Status: current Access: read-write
OBJECT-TYPE    
  ShePhysShelfExternalAlarmOutputStatusType  

shePhysicalConformance 1.3.6.1.4.1.231.7.1.2.1.1.100
OBJECT IDENTIFIER    

shePhysicalGroups 1.3.6.1.4.1.231.7.1.2.1.1.100.1
OBJECT IDENTIFIER    

shePhysicalGroup 1.3.6.1.4.1.231.7.1.2.1.1.100.1.1
Description.
Status: current Access: read-write
OBJECT-GROUP    

shePhysicalControlGroup 1.3.6.1.4.1.231.7.1.2.1.1.100.1.2
Description.
Status: current Access: read-write
OBJECT-GROUP    

shePhysicalNotificationGroup 1.3.6.1.4.1.231.7.1.2.1.1.100.1.3
This group supports notifications of significant conditions associated with physical objects.
Status: current Access: read-write
NOTIFICATION-GROUP    

shePhysicalObsoleteGroup 1.3.6.1.4.1.231.7.1.2.1.1.100.1.4
Description.
Status: obsolete Access: read-write
OBJECT-GROUP    

shePhysicalObsoleteNotificationGroup 1.3.6.1.4.1.231.7.1.2.1.1.100.1.5
Description.
Status: obsolete Access: read-write
NOTIFICATION-GROUP    

shePhysicalCompliances 1.3.6.1.4.1.231.7.1.2.1.1.100.2
OBJECT IDENTIFIER    

shePhysicalMibCompliance 1.3.6.1.4.1.231.7.1.2.1.1.100.2.1
The compliance statement for SNMP entities which manage physical interfaces in SHE.
Status: current Access: read-write
MODULE-COMPLIANCE