SIAE-EQUIP-MIB
File:
SIAE-EQUIP-MIB.mib (21467 bytes)
Imported modules
Imported symbols
Defined Values
equipment |
1.3.6.1.4.1.3373.1103.1 |
Common parameters of SIAE equipments.
|
MODULE-IDENTITY |
|
|
|
equipMibVersion |
1.3.6.1.4.1.3373.1103.1.1 |
Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
equipUpTime |
1.3.6.1.4.1.3373.1103.1.3 |
The time since the system was last re-initialized (in seconds
since 1/1/1970). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
equipType |
1.3.6.1.4.1.3373.1103.1.4 |
Type of SIAE MICROELETTRONICA's equipment |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AutonomousType |
|
|
equipIpEthOsiAddress |
1.3.6.1.4.1.3373.1103.1.6 |
Ip address of the equipment on Ethernet-OSI interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipGosipAddress |
1.3.6.1.4.1.3373.1103.1.7 |
GOSIP address of the equipment. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..20) |
|
equipIpEthOsiNetMask |
1.3.6.1.4.1.3373.1103.1.8 |
The subnet Mask associated with the IP address of OSI ethernet interface.
The value of the Mask is an IP address with all the network bits set to 1
and all the hosts bits set to 0. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipL1L2IsIsRouting |
1.3.6.1.4.1.3373.1103.1.9 |
It defines the IS-IS routing type: L1 within the same area, L2 among
different areas. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
l1(1), l2(2) |
|
equipStationID |
1.3.6.1.4.1.3373.1103.1.10 |
ASCII string assigned by the operator to identify the specific equipment. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..63) |
|
equipLOMConfigEnable |
1.3.6.1.4.1.3373.1103.1.11 |
Enables/disables the capabilityto connect a LOM in Configuration Mode. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), enable(2) |
|
equipLOMConnected |
1.3.6.1.4.1.3373.1103.1.12 |
Signal when the LOM is connected to the NE and if the connection
is for monitor or configuration. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cleared(1), connectionAsMonitor(2), connectionAsConfig(3) |
|
equipLOMConnectedTrapEnable |
1.3.6.1.4.1.3373.1103.1.13 |
Enables/disables the trap generation on EquipLOMConnected status change event. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
trapDisable(1), trapEnable(2), trapEnableWithAck(3) |
|
equipConfigChange |
1.3.6.1.4.1.3373.1103.1.14 |
Set by the NE when the equipment configuration is changed by the local
or Remote LOM.
The octet string is a bit stream of flags; a set bit is a change on a
specific item. We had:
Byte 0.7: change in configuration for equipment group
Byte 0.6: change in configuration for userInput group
Byte 0.5: change in configuration for userOutput group
Byte 0.4: change in configuration for alarmLog group
......
Byte 3.7: change in a severity for equipment group
Byte 3.6: change in a severity for userInput group
Byte 3.5: change in a severity for userOutput group
Byte 3.4: change in a severity for alarmLog group
CEM can reset the change condition writing one to desired bit flag
...... |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(6) |
|
equipConfigChangeTrapEnable |
1.3.6.1.4.1.3373.1103.1.15 |
Enables/disables the trap generation on EquipConfigChange status
change event. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
trapDisable(1), trapEnable(2), trapEnableWithACK(3) |
|
equipRequest |
1.3.6.1.4.1.3373.1103.1.16 |
Force Equipment Controller restart or change in interface properties. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notActive(0), restart(1), applyIfChange(2), revertIfChange(3), configClearAndRestart(4), routeTableClear(5), uploadBaseBand(6), offLineRouteRetrieve(7), offLineRouteSave(8), hotApplyIfChange(11), ipStackConfigure(20), osiStackConfigure(21), atuTableReset(50), siaeReservedReq1(100), siaeReservedReq26(125), siaeReservedReq27(126), switchFactoryDefault(127) |
|
equipIpEthAddress |
1.3.6.1.4.1.3373.1103.1.17 |
Ip address of the equipment on Ethernet interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipIpEthNetMask |
1.3.6.1.4.1.3373.1103.1.18 |
The subnet Mask associated with the IP address of ethernet interface.
The value of the Mask is an IP address with all the network bits set to 1
and all the hosts bits set to 0. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipOsiamParameter |
1.3.6.1.4.1.3373.1103.1.19 |
It defines the set-up parameter for OSI stack. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..41) |
|
equipIpSnmpAgentAddress |
1.3.6.1.4.1.3373.1103.1.20 |
Ip address used by SNMP Agent for mark generated TRAP. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipManagerWakeUpAlarm |
1.3.6.1.4.1.3373.1103.1.22 |
This alarm switches on when periodic connection wake-up trap starts.
The trap related to this alarm is also sent periodically only to the
manager specified by the leaf equipManagerWakeUpIpAddr when
equipManagerWakeUpAlarmSeverityCode differs from disable. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AlarmStatus |
|
|
equipManagerWakeUpTimeout |
1.3.6.1.4.1.3373.1103.1.24 |
This object defines the time (in minutes) after which the periodic
connection wake-up trap is stopped.
The maximium value is equivalent to 24 hours.
When the timeout elapses the equipManagerWakeUpAlarmSeverityCode
is set to disable.
A zero means no timeout. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1440 |
|
equipManagerWakeUpIpAddr |
1.3.6.1.4.1.3373.1103.1.25 |
Ip Address of manager wich to send a periodic connection wake-up trap.
The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode
differs from disable.
If Ip Address equals 0 no trap will be sent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipManagerWakeUpGosipAddress |
1.3.6.1.4.1.3373.1103.1.26 |
Gosip Address of manager wich to send a periodic connection wake-up trap. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..20) |
|
equipManagerWakeUpTrapVersion |
1.3.6.1.4.1.3373.1103.1.27 |
Trap version supported by Manager to wake-up. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
trapV1(1), trapV2(2), trapV3(3) |
|
equipManager1IpAddr |
1.3.6.1.4.1.3373.1103.1.28 |
First IP address of a SNMP Manager always logged to this equipment.
The address 0.0.0.0 mean that manager is not present. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipManager2IpAddr |
1.3.6.1.4.1.3373.1103.1.29 |
Second IP address of a SNMP Manager always logged to this equipment.
The address 0.0.0.0 mean that manager is not present. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipManager1TrapVersion |
1.3.6.1.4.1.3373.1103.1.30 |
Trap version supported by Manager 1 (related to equipManager1IpAddr). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
trapV1(1), trapV2(2), trapV3(3) |
|
equipManager2TrapVersion |
1.3.6.1.4.1.3373.1103.1.31 |
Trap version supported by Manager 2 (related to equipManager2IpAddr). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
trapV1(1), trapV2(2), trapV3(3) |
|
equipDailyPmTimeZone |
1.3.6.1.4.1.3373.1103.1.32 |
Reference GMT Time Zone to close the daily P.M. records. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-12..12 |
|
equipOperationMngtControl |
1.3.6.1.4.1.3373.1103.1.33 |
startOperation means the apply of the 'management parameters
set' on the E6165 switch.
confirmOperation means the backup of the 'management
parameters set'. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notActive(0), startOperation(1), confirmOperation(2) |
|
equipOperationMngtInProgress |
1.3.6.1.4.1.3373.1103.1.34 |
A value different from 0 means Mngt operation in progress. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
equipLocation |
1.3.6.1.4.1.3373.1103.1.35 |
ASCII string assigned by the operator to identify the location of
specific equipment. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..31) |
|
equipLongitude |
1.3.6.1.4.1.3373.1103.1.36 |
Geographic coordinate that specifies the east-west position of
the equipment.
In order to calculate the latitude in degrees the formula to be
applied is
Longitude = equipLongitude*180/2^31
This object is used with equipLatitude to locate the equipment
on a map.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
equipLatitude |
1.3.6.1.4.1.3373.1103.1.37 |
Geographic coordinate that specifies the north-south position of
the equipment.
In order to calculate the latitude in degrees the formula to be
applied is
Latitude = equipLatitude*180/2^31
This object is used with equipLongitude to locate the equipment
on a map.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
equipIpEthVlanId |
1.3.6.1.4.1.3373.1103.1.38 |
Ethernet vlan id on top of which management is built |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..4094 |
|
equipIpEthDefGateway |
1.3.6.1.4.1.3373.1103.1.39 |
Ip address of the default gateway on Ethernet interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
equipLOMConnectedMonitor |
1.3.6.1.4.1.3373.1103.0.109 |
This event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipLOMConnected |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
equipLOMConnectedConfig |
1.3.6.1.4.1.3373.1103.0.110 |
This event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipLOMConnected |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
equipLOMDisconnected |
1.3.6.1.4.1.3373.1103.0.111 |
This event is generated by ALFOHD-NE when LOMConnected is cleared.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipLOMConnected |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
equipConfigChangeStatus |
1.3.6.1.4.1.3373.1103.0.114 |
This event is generated by ALFOHD-NE when equipConfigChange is changed.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipConfigChange |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
equipManagerWakeUpNotify |
1.3.6.1.4.1.3373.1103.0.123 |
This trap is sent periodically only to the manager specified by
the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode
differs from disable.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipStationID
3) equipLocation
4) equipIpSnmpAgentAddress
5) equipGosipAddress
6) equipManagerWakeUpIpAddr
7) equipManagerWakeUpAlarm |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|