SIAE-EQUIP-MIB

File: SIAE-EQUIP-MIB.mib (21467 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
SIAE-TREE-MIB SIAE-ALARM-MIB SIAE-EQUIPTYPE-MIB

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Integer32 IpAddress TimeTicks
DisplayString AutonomousType InterfaceIndex
siaeMib AlarmStatus AlarmSeverityCode
alarmTrap equipTypeUnknown

Defined Values

equipment 1.3.6.1.4.1.3373.1103.1
Common parameters of SIAE equipments.
MODULE-IDENTITY    

equipMibVersion 1.3.6.1.4.1.3373.1103.1.1
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

equipCurrentTime 1.3.6.1.4.1.3373.1103.1.2
Seconds since 1/1/1970.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

equipUpTime 1.3.6.1.4.1.3373.1103.1.3
The time since the system was last re-initialized (in seconds since 1/1/1970).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

equipType 1.3.6.1.4.1.3373.1103.1.4
Type of SIAE MICROELETTRONICA's equipment
Status: current Access: read-only
OBJECT-TYPE    
  AutonomousType  

equipIpEthOsiAddress 1.3.6.1.4.1.3373.1103.1.6
Ip address of the equipment on Ethernet-OSI interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipGosipAddress 1.3.6.1.4.1.3373.1103.1.7
GOSIP address of the equipment.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

equipIpEthOsiNetMask 1.3.6.1.4.1.3373.1103.1.8
The subnet Mask associated with the IP address of OSI ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipL1L2IsIsRouting 1.3.6.1.4.1.3373.1103.1.9
It defines the IS-IS routing type: L1 within the same area, L2 among different areas.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER l1(1), l2(2)  

equipStationID 1.3.6.1.4.1.3373.1103.1.10
ASCII string assigned by the operator to identify the specific equipment.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

equipLOMConfigEnable 1.3.6.1.4.1.3373.1103.1.11
Enables/disables the capabilityto connect a LOM in Configuration Mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

equipLOMConnected 1.3.6.1.4.1.3373.1103.1.12
Signal when the LOM is connected to the NE and if the connection is for monitor or configuration.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cleared(1), connectionAsMonitor(2), connectionAsConfig(3)  

equipLOMConnectedTrapEnable 1.3.6.1.4.1.3373.1103.1.13
Enables/disables the trap generation on EquipLOMConnected status change event.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trapDisable(1), trapEnable(2), trapEnableWithAck(3)  

equipConfigChange 1.3.6.1.4.1.3373.1103.1.14
Set by the NE when the equipment configuration is changed by the local or Remote LOM. The octet string is a bit stream of flags; a set bit is a change on a specific item. We had: Byte 0.7: change in configuration for equipment group Byte 0.6: change in configuration for userInput group Byte 0.5: change in configuration for userOutput group Byte 0.4: change in configuration for alarmLog group ...... Byte 3.7: change in a severity for equipment group Byte 3.6: change in a severity for userInput group Byte 3.5: change in a severity for userOutput group Byte 3.4: change in a severity for alarmLog group CEM can reset the change condition writing one to desired bit flag ......
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

equipConfigChangeTrapEnable 1.3.6.1.4.1.3373.1103.1.15
Enables/disables the trap generation on EquipConfigChange status change event.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trapDisable(1), trapEnable(2), trapEnableWithACK(3)  

equipRequest 1.3.6.1.4.1.3373.1103.1.16
Force Equipment Controller restart or change in interface properties.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notActive(0), restart(1), applyIfChange(2), revertIfChange(3), configClearAndRestart(4), routeTableClear(5), uploadBaseBand(6), offLineRouteRetrieve(7), offLineRouteSave(8), hotApplyIfChange(11), ipStackConfigure(20), osiStackConfigure(21), atuTableReset(50), siaeReservedReq1(100), siaeReservedReq26(125), siaeReservedReq27(126), switchFactoryDefault(127)  

equipIpEthAddress 1.3.6.1.4.1.3373.1103.1.17
Ip address of the equipment on Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipIpEthNetMask 1.3.6.1.4.1.3373.1103.1.18
The subnet Mask associated with the IP address of ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipOsiamParameter 1.3.6.1.4.1.3373.1103.1.19
It defines the set-up parameter for OSI stack.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..41)  

equipIpSnmpAgentAddress 1.3.6.1.4.1.3373.1103.1.20
Ip address used by SNMP Agent for mark generated TRAP.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipOperationInProgress 1.3.6.1.4.1.3373.1103.1.21
A value different from 0 means operation in progress.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

equipManagerWakeUpAlarm 1.3.6.1.4.1.3373.1103.1.22
This alarm switches on when periodic connection wake-up trap starts. The trap related to this alarm is also sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmStatus  

equipManagerWakeUpAlarmSeverityCode 1.3.6.1.4.1.3373.1103.1.23
Defines the severity associated to the equipManagerWakeUpAlarm and enables/disables the trap generation on status change event.
Status: current Access: read-write
OBJECT-TYPE    
  AlarmSeverityCode  

equipManagerWakeUpTimeout 1.3.6.1.4.1.3373.1103.1.24
This object defines the time (in minutes) after which the periodic connection wake-up trap is stopped. The maximium value is equivalent to 24 hours. When the timeout elapses the equipManagerWakeUpAlarmSeverityCode is set to disable. A zero means no timeout.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1440  

equipManagerWakeUpIpAddr 1.3.6.1.4.1.3373.1103.1.25
Ip Address of manager wich to send a periodic connection wake-up trap. The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode differs from disable. If Ip Address equals 0 no trap will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipManagerWakeUpGosipAddress 1.3.6.1.4.1.3373.1103.1.26
Gosip Address of manager wich to send a periodic connection wake-up trap.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

equipManagerWakeUpTrapVersion 1.3.6.1.4.1.3373.1103.1.27
Trap version supported by Manager to wake-up.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trapV1(1), trapV2(2), trapV3(3)  

equipManager1IpAddr 1.3.6.1.4.1.3373.1103.1.28
First IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipManager2IpAddr 1.3.6.1.4.1.3373.1103.1.29
Second IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipManager1TrapVersion 1.3.6.1.4.1.3373.1103.1.30
Trap version supported by Manager 1 (related to equipManager1IpAddr).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trapV1(1), trapV2(2), trapV3(3)  

equipManager2TrapVersion 1.3.6.1.4.1.3373.1103.1.31
Trap version supported by Manager 2 (related to equipManager2IpAddr).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trapV1(1), trapV2(2), trapV3(3)  

equipDailyPmTimeZone 1.3.6.1.4.1.3373.1103.1.32
Reference GMT Time Zone to close the daily P.M. records.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -12..12  

equipOperationMngtControl 1.3.6.1.4.1.3373.1103.1.33
startOperation means the apply of the 'management parameters set' on the E6165 switch. confirmOperation means the backup of the 'management parameters set'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notActive(0), startOperation(1), confirmOperation(2)  

equipOperationMngtInProgress 1.3.6.1.4.1.3373.1103.1.34
A value different from 0 means Mngt operation in progress.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

equipLocation 1.3.6.1.4.1.3373.1103.1.35
ASCII string assigned by the operator to identify the location of specific equipment.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

equipLongitude 1.3.6.1.4.1.3373.1103.1.36
Geographic coordinate that specifies the east-west position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Longitude = equipLongitude*180/2^31 This object is used with equipLatitude to locate the equipment on a map.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

equipLatitude 1.3.6.1.4.1.3373.1103.1.37
Geographic coordinate that specifies the north-south position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Latitude = equipLatitude*180/2^31 This object is used with equipLongitude to locate the equipment on a map.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

equipIpEthVlanId 1.3.6.1.4.1.3373.1103.1.38
Ethernet vlan id on top of which management is built
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4094  

equipIpEthDefGateway 1.3.6.1.4.1.3373.1103.1.39
Ip address of the default gateway on Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

equipIpEthDefGatewayIfIndex 1.3.6.1.4.1.3373.1103.1.40
Ip address of the default gateway on Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex 1..999  

equipLOMConnectedMonitor 1.3.6.1.4.1.3373.1103.0.109
This event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected
Status: current Access: read-write
NOTIFICATION-TYPE    

equipLOMConnectedConfig 1.3.6.1.4.1.3373.1103.0.110
This event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected
Status: current Access: read-write
NOTIFICATION-TYPE    

equipLOMDisconnected 1.3.6.1.4.1.3373.1103.0.111
This event is generated by ALFOHD-NE when LOMConnected is cleared. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected
Status: current Access: read-write
NOTIFICATION-TYPE    

equipConfigChangeStatus 1.3.6.1.4.1.3373.1103.0.114
This event is generated by ALFOHD-NE when equipConfigChange is changed. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipConfigChange
Status: current Access: read-write
NOTIFICATION-TYPE    

equipManagerWakeUpNotify 1.3.6.1.4.1.3373.1103.0.123
This trap is sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipStationID 3) equipLocation 4) equipIpSnmpAgentAddress 5) equipGosipAddress 6) equipManagerWakeUpIpAddr 7) equipManagerWakeUpAlarm
Status: current Access: read-write