SITE-MONITORING-MIB

File: SITE-MONITORING-MIB.mib (187887 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF

Imported symbols

enterprises MODULE-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE Unsigned32 Integer32
DisplayString RowStatus MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP

Defined Types

SiteV1DescriptionEntry  
SEQUENCE    
  siteV1DescriptionIndex Unsigned32
  siteV1DescriptionName DisplayString
  siteV1DescriptionValue DisplayString
  siteV1DescriptionEntryStatus RowStatus

SiteV1AlarmEntry  
SEQUENCE    
  siteV1AlarmIndex Unsigned32
  siteV1AlarmName DisplayString
  siteV1AlarmActive DisplayString
  siteV1AlarmSeverityType DisplayString
  siteV1AlarmSeverityLevel DisplayString
  siteV1AlarmStartTime DisplayString
  siteV1AlarmStopTime DisplayString
  siteV1AlarmEntryStatus RowStatus

SiteV1EventEntry  
SEQUENCE    
  siteV1EventIndex Unsigned32
  siteV1EventId Unsigned32
  siteV1EventName DisplayString
  siteV1EventDateTime DisplayString
  siteV1EventSeverityType DisplayString
  siteV1EventSeverityLevel DisplayString
  siteV1EventEntryStatus RowStatus

SiteV1DataEntry  
SEQUENCE    
  siteV1DataIndex Unsigned32
  siteV1DataName DisplayString
  siteV1DataValue DisplayString
  siteV1DataEntryStatus RowStatus

SiteV1ConfigEntry  
SEQUENCE    
  siteV1ConfigIndex Unsigned32
  siteV1ConfigName DisplayString
  siteV1ConfigValue DisplayString
  siteV1ConfigEntryStatus RowStatus

SiteV1ControlEntry  
SEQUENCE    
  siteV1ControlIndex Unsigned32
  siteV1ControlName DisplayString
  siteV1ControlValue DisplayString
  siteV1ControlEntryStatus RowStatus

Es1DescriptionEntry  
SEQUENCE    
  es1DescriptionIndex Unsigned32
  es1DescriptionName DisplayString
  es1DescriptionValue DisplayString
  es1DescriptionEntryStatus RowStatus

Es1AlarmEntry  
SEQUENCE    
  es1AlarmIndex Unsigned32
  es1AlarmName DisplayString
  es1AlarmActive DisplayString
  es1AlarmSeverityType DisplayString
  es1AlarmSeverityLevel DisplayString
  es1AlarmStartTime DisplayString
  es1AlarmStopTime DisplayString
  es1AlarmEntryStatus RowStatus

Es1EventEntry  
SEQUENCE    
  es1EventIndex Unsigned32
  es1EventId Unsigned32
  es1EventName DisplayString
  es1EventDateTime DisplayString
  es1EventSeverityType DisplayString
  es1EventSeverityLevel DisplayString
  es1EventEntryStatus RowStatus

Es1ConfigEntry  
SEQUENCE    
  es1ConfigIndex Unsigned32
  es1ConfigName DisplayString
  es1ConfigValue DisplayString
  es1ConfigEntryStatus RowStatus

Es1ControlEntry  
SEQUENCE    
  es1ControlIndex Unsigned32
  es1ControlName DisplayString
  es1ControlValue DisplayString
  es1ControlEntryStatus RowStatus

Es1dc1DescriptionEntry  
SEQUENCE    
  es1dc1DescriptionIndex Unsigned32
  es1dc1DescriptionName DisplayString
  es1dc1DescriptionValue DisplayString
  es1dc1DescriptionEntryStatus RowStatus

Es1dc1AlarmEntry  
SEQUENCE    
  es1dc1AlarmIndex Unsigned32
  es1dc1AlarmName DisplayString
  es1dc1AlarmActive DisplayString
  es1dc1AlarmSeverityType DisplayString
  es1dc1AlarmSeverityLevel DisplayString
  es1dc1AlarmStartTime DisplayString
  es1dc1AlarmStopTime DisplayString
  es1dc1AlarmEntryStatus RowStatus

Es1dc1EventEntry  
SEQUENCE    
  es1dc1EventIndex Unsigned32
  es1dc1EventId Unsigned32
  es1dc1EventName DisplayString
  es1dc1EventDateTime DisplayString
  es1dc1EventSeverityType DisplayString
  es1dc1EventSeverityLevel DisplayString
  es1dc1EventEntryStatus RowStatus

Es1dc1DataEntry  
SEQUENCE    
  es1dc1DataIndex Unsigned32
  es1dc1DataName DisplayString
  es1dc1DataValue DisplayString
  es1dc1DataEntryStatus RowStatus

Es1dc1ConfigEntry  
SEQUENCE    
  es1dc1ConfigIndex Unsigned32
  es1dc1ConfigName DisplayString
  es1dc1ConfigValue DisplayString
  es1dc1ConfigEntryStatus RowStatus

Es1dc1ControlEntry  
SEQUENCE    
  es1dc1ControlIndex Unsigned32
  es1dc1ControlName DisplayString
  es1dc1ControlValue DisplayString
  es1dc1ControlEntryStatus RowStatus

Defined Values

siteMonitoringMIB 1.3.6.1.4.1.26854.1.1
Alpha Innovations SNMP corporate naming convention Organises the SNMP OIDs according to the design centres that generate the different MIBs
MODULE-IDENTITY    

atsa 1.3.6.1.4.1.26854
OBJECT IDENTIFIER    

atsaCorporate 1.3.6.1.4.1.26854.1
OBJECT IDENTIFIER    

atsaUs 1.3.6.1.4.1.26854.2
OBJECT IDENTIFIER    

atsaEu 1.3.6.1.4.1.26854.3
OBJECT IDENTIFIER    

atsaEuDevices 1.3.6.1.4.1.26854.3.1
OBJECT IDENTIFIER    

siteMonitoring 1.3.6.1.4.1.26854.3.2
OBJECT IDENTIFIER    

siteV1 1.3.6.1.4.1.26854.3.2.1
OBJECT IDENTIFIER    

siteV1GlobalStatus 1.3.6.1.4.1.26854.3.2.1.1
A textual string (alarms, normal or unknown) containing the status of the Site
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

siteV1GlobalAlarmSeverityType 1.3.6.1.4.1.26854.3.2.1.2
The alarm severity type (critical, major, minor, warning, none, disabled) of the Site
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1GlobalAlarmSeverityLevel 1.3.6.1.4.1.26854.3.2.1.3
The alarm severity level (0-9) of the Site
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1GlobalAlarmSeverityTypeInt 1.3.6.1.4.1.26854.3.2.1.4
The alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the Site
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1Description 1.3.6.1.4.1.26854.3.2.1.10
OBJECT IDENTIFIER    

siteV1DescriptionNumber 1.3.6.1.4.1.26854.3.2.1.10.1
The number of entries in the Site Description table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DescriptionTable 1.3.6.1.4.1.26854.3.2.1.10.2
The Description table of the Site
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SiteV1DescriptionEntry

siteV1DescriptionEntry 1.3.6.1.4.1.26854.3.2.1.10.2.1
A Description entry
Status: current Access: not-accessible
OBJECT-TYPE    
  SiteV1DescriptionEntry  

siteV1DescriptionIndex 1.3.6.1.4.1.26854.3.2.1.10.2.1.1
Description Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

siteV1DescriptionName 1.3.6.1.4.1.26854.3.2.1.10.2.1.2
Description Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescriptionValue 1.3.6.1.4.1.26854.3.2.1.10.2.1.3
Description Value
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

siteV1DescriptionEntryStatus 1.3.6.1.4.1.26854.3.2.1.10.2.1.4
The status of this table entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

siteV1DescriptionList 1.3.6.1.4.1.26854.3.2.1.10.3
OBJECT IDENTIFIER    

siteV1DescDescriptionSiteNumber 1.3.6.1.4.1.26854.3.2.1.10.3.1
The identification number of the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionSiteName 1.3.6.1.4.1.26854.3.2.1.10.3.2
The name of the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionShortDescription 1.3.6.1.4.1.26854.3.2.1.10.3.3
A short description of the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionInfo 1.3.6.1.4.1.26854.3.2.1.10.3.4
Some more information about the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionDescription 1.3.6.1.4.1.26854.3.2.1.10.3.5
A free text zone to write a system description
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionReference 1.3.6.1.4.1.26854.3.2.1.10.3.6
A free text zone to write the customer reference of the system
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionContactName 1.3.6.1.4.1.26854.3.2.1.10.3.7
Contact Name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionPhoneNumber 1.3.6.1.4.1.26854.3.2.1.10.3.8
Phone Number
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionStreet 1.3.6.1.4.1.26854.3.2.1.10.3.11
Street part of the site address
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionCity 1.3.6.1.4.1.26854.3.2.1.10.3.12
City part of the site address
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionProvince 1.3.6.1.4.1.26854.3.2.1.10.3.13
Province part of the site address
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionPostalCode 1.3.6.1.4.1.26854.3.2.1.10.3.14
Postal Code part of the site address
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionRegion 1.3.6.1.4.1.26854.3.2.1.10.3.15
Region part of the site address
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionCountry 1.3.6.1.4.1.26854.3.2.1.10.3.16
Country part of the site address
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionGroup1 1.3.6.1.4.1.26854.3.2.1.10.3.21
Group Level 1 (For Armada Clustering)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionGroup2 1.3.6.1.4.1.26854.3.2.1.10.3.22
Group Level 2 (For Armada Clustering)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionGroup3 1.3.6.1.4.1.26854.3.2.1.10.3.23
Group Level 3 (For Armada Clustering)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionGroup4 1.3.6.1.4.1.26854.3.2.1.10.3.24
Group Level 4 (For Armada Clustering)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionGroup5 1.3.6.1.4.1.26854.3.2.1.10.3.25
Group Level 5 (For Armada Clustering)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionLatitude 1.3.6.1.4.1.26854.3.2.1.10.3.31
The latitude of the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionLongitude 1.3.6.1.4.1.26854.3.2.1.10.3.32
The longitude of the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescDescriptionAltitude 1.3.6.1.4.1.26854.3.2.1.10.3.33
The altitude of the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerSoftwareRevision 1.3.6.1.4.1.26854.3.2.1.10.3.91
The software revision of Comp@s (read only)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerOperatingSystemRevision 1.3.6.1.4.1.26854.3.2.1.10.3.92
The operating system of Comp@s (read only)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerCPU 1.3.6.1.4.1.26854.3.2.1.10.3.93
Information about the CPU
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerCard 1.3.6.1.4.1.26854.3.2.1.10.3.94
Information about the hardware system containing Compas
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerStarterVersion 1.3.6.1.4.1.26854.3.2.1.10.3.100
Information about the starter component of Compas
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerFactoryCompasVersion 1.3.6.1.4.1.26854.3.2.1.10.3.105
Information about the revision of Compas in Factory folder
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerUserCompasVersion 1.3.6.1.4.1.26854.3.2.1.10.3.106
Information about the revision of Compas in user folder
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerFactoryFTPServerVersion 1.3.6.1.4.1.26854.3.2.1.10.3.110
Information about the revision of Ftp Server in Factory folder
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DescControllerUserFTPServerVersion 1.3.6.1.4.1.26854.3.2.1.10.3.111
Information about the revision of Ftp Server in Factory folder
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1Alarm 1.3.6.1.4.1.26854.3.2.1.11
OBJECT IDENTIFIER    

siteV1AlarmNumber 1.3.6.1.4.1.26854.3.2.1.11.1
The number of entries in the Site Alarm table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1AlarmTable 1.3.6.1.4.1.26854.3.2.1.11.2
The table of Alarm entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SiteV1AlarmEntry

siteV1AlarmEntry 1.3.6.1.4.1.26854.3.2.1.11.2.1
An alarm entry
Status: current Access: not-accessible
OBJECT-TYPE    
  SiteV1AlarmEntry  

siteV1AlarmIndex 1.3.6.1.4.1.26854.3.2.1.11.2.1.1
Alarm Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

siteV1AlarmName 1.3.6.1.4.1.26854.3.2.1.11.2.1.2
Alarm Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1AlarmActive 1.3.6.1.4.1.26854.3.2.1.11.2.1.3
Is the Alarm active ? 'true' for active, 'false' for not-active
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1AlarmSeverityType 1.3.6.1.4.1.26854.3.2.1.11.2.1.4
The alarm severity type (major, minor, warning, none, disabled) of this alarm entry
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1AlarmSeverityLevel 1.3.6.1.4.1.26854.3.2.1.11.2.1.5
The alarm severity level (0-9) of this alarm entry
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1AlarmStartTime 1.3.6.1.4.1.26854.3.2.1.11.2.1.6
The last start time of this alarm entry (null if never active)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1AlarmStopTime 1.3.6.1.4.1.26854.3.2.1.11.2.1.7
The last stop time of this alarm entry (null if alarm active)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1AlarmEntryStatus 1.3.6.1.4.1.26854.3.2.1.11.2.1.8
The status of this table entry - not used, only for MIB compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

siteV1AlarmSummary 1.3.6.1.4.1.26854.3.2.1.11.3
Summary bit vector with all the alarms state of the Site. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.
Status: current Access: read-only
OBJECT-TYPE    
  BITS inventoryCANBusFail(0), inventoryCANBusAddressingError(1), inventoryMissingCANBusNodeIDs(2), inventoryRunningCANLSSDeviceDetection(3), inventoryRunningCANFirmwareUpgrade(4), controllerControllerRebootRequired(10), controllerLastConfChangesUnsaved(14), xMLXMLHeartbeatPostFail(20)  

siteV1Event 1.3.6.1.4.1.26854.3.2.1.12
OBJECT IDENTIFIER    

siteV1EventNumber 1.3.6.1.4.1.26854.3.2.1.12.1
The number of entries in the Event Table related to the Site
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1EventTable 1.3.6.1.4.1.26854.3.2.1.12.2
The Event table related to the Site
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SiteV1EventEntry

siteV1EventEntry 1.3.6.1.4.1.26854.3.2.1.12.2.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  SiteV1EventEntry  

siteV1EventIndex 1.3.6.1.4.1.26854.3.2.1.12.2.1.1
Event Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

siteV1EventId 1.3.6.1.4.1.26854.3.2.1.12.2.1.2
Event Index
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

siteV1EventName 1.3.6.1.4.1.26854.3.2.1.12.2.1.3
Event Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1EventDateTime 1.3.6.1.4.1.26854.3.2.1.12.2.1.4
The date and time of the event
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1EventSeverityType 1.3.6.1.4.1.26854.3.2.1.12.2.1.5
The event severity type ('major', 'minor', 'warning' or 'none')
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1EventSeverityLevel 1.3.6.1.4.1.26854.3.2.1.12.2.1.6
The event severity level (0-9)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1EventEntryStatus 1.3.6.1.4.1.26854.3.2.1.12.2.1.7
The status of this table entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

siteV1Data 1.3.6.1.4.1.26854.3.2.1.13
OBJECT IDENTIFIER    

siteV1DataNumber 1.3.6.1.4.1.26854.3.2.1.13.1
The number of entries in the Data Table related to the Site
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataTable 1.3.6.1.4.1.26854.3.2.1.13.2
The table of Data entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SiteV1DataEntry

siteV1DataEntry 1.3.6.1.4.1.26854.3.2.1.13.2.1
A data entry
Status: current Access: not-accessible
OBJECT-TYPE    
  SiteV1DataEntry  

siteV1DataIndex 1.3.6.1.4.1.26854.3.2.1.13.2.1.1
The data index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

siteV1DataName 1.3.6.1.4.1.26854.3.2.1.13.2.1.2
The data name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DataValue 1.3.6.1.4.1.26854.3.2.1.13.2.1.3
The data value
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DataEntryStatus 1.3.6.1.4.1.26854.3.2.1.13.2.1.4
The status of this table entry - not used, only present for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

siteV1DataList 1.3.6.1.4.1.26854.3.2.1.13.3
OBJECT IDENTIFIER    

siteV1DataNetworkCurrentIPAddress 1.3.6.1.4.1.26854.3.2.1.13.3.1
This is the actual IP address of the Comp@s platform. If the Ethernet cable is not correctly connected, the address will be 0.0.0.0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataNetworkCurrentIPMask 1.3.6.1.4.1.26854.3.2.1.13.3.2
This is the actual IP address of the Comp@s platform. If the Ethernet cable is not correctly connected, the address will be 0.0.0.0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataNetworkCurrentMACAddress 1.3.6.1.4.1.26854.3.2.1.13.3.3
This is the MAC address of IP interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataControllerLicensedOptions 1.3.6.1.4.1.26854.3.2.1.13.3.11
This is the options of the actual license.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataTimeDateAndTimeLocal 1.3.6.1.4.1.26854.3.2.1.13.3.21
This is the local time of the monitoring.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DataTimeDateAndTimeUTC 1.3.6.1.4.1.26854.3.2.1.13.3.22
This is the UTC time of the monitoring.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DataControllerMonitoringMemoryUsed 1.3.6.1.4.1.26854.3.2.1.13.3.31
This is actual amount of RAM memory used by the application.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataControllerCPUPercentageUsage 1.3.6.1.4.1.26854.3.2.1.13.3.32
This is actual percentage of CPU used
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataControllerFreeFlashMemorySpace 1.3.6.1.4.1.26854.3.2.1.13.3.33
This is free flash memory available on the Comp@s card, in Megabytes
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataControllerFTPServerStatus 1.3.6.1.4.1.26854.3.2.1.13.3.35
Status of the FTP Server. Compatible only with version >= 2.26.X.X. The configuration is available at controller -> FTP Server page.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1DataDataRecordsTotalFifoSizeOfSecondRecords 1.3.6.1.4.1.26854.3.2.1.13.3.41
NA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataDataRecordsTotalFifoSizeOfMinuteRecords 1.3.6.1.4.1.26854.3.2.1.13.3.42
NA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataDataRecordsTotalFifoSizeOfHourRecords 1.3.6.1.4.1.26854.3.2.1.13.3.43
NA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataDataRecordsTotalFifoSizeOfDayRecords 1.3.6.1.4.1.26854.3.2.1.13.3.44
NA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataInventoryCANBusNodeIDs 1.3.6.1.4.1.26854.3.2.1.13.3.51
The coma separated list of the node ids present on the CAN bus.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1DataCloudLinkCloudLinkState 1.3.6.1.4.1.26854.3.2.1.13.3.166
Cloud Link State
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1Config 1.3.6.1.4.1.26854.3.2.1.15
OBJECT IDENTIFIER    

siteV1ConfigNumber 1.3.6.1.4.1.26854.3.2.1.15.1
The number of entries in the Config table related to the Site
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1ConfigTable 1.3.6.1.4.1.26854.3.2.1.15.2
The table of Config entries related to the Site
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SiteV1ConfigEntry

siteV1ConfigEntry 1.3.6.1.4.1.26854.3.2.1.15.2.1
A Config entry
Status: current Access: not-accessible
OBJECT-TYPE    
  SiteV1ConfigEntry  

siteV1ConfigIndex 1.3.6.1.4.1.26854.3.2.1.15.2.1.1
The Config entry Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

siteV1ConfigName 1.3.6.1.4.1.26854.3.2.1.15.2.1.2
The Config entry name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1ConfigValue 1.3.6.1.4.1.26854.3.2.1.15.2.1.3
The Config entry value
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1ConfigEntryStatus 1.3.6.1.4.1.26854.3.2.1.15.2.1.4
The status of this table entry - not used, only for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

siteV1ConfigList 1.3.6.1.4.1.26854.3.2.1.15.3
OBJECT IDENTIFIER    

siteV1CfgNetworkDHCPEnabled 1.3.6.1.4.1.26854.3.2.1.15.3.1
The monitoring will try to get an IP with the DHCP protocol if this parameter is set to True. By default, this parameter is set to False.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgNetworkIPAddressIfStatic 1.3.6.1.4.1.26854.3.2.1.15.3.2
The static IP address of the monitoring. This configuration parameter is not used if the DHCP is enabled. The default IP is 192.168.45.2.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgNetworkSubnetMaskIfStatic 1.3.6.1.4.1.26854.3.2.1.15.3.3
The static Subnet Mask of the monitoring. This configuration parameter is not used if the DHCP is enabled. The default mask is 255.255.255.0.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgNetworkDefaultGatewayIfStatic 1.3.6.1.4.1.26854.3.2.1.15.3.4
The static Default Gateway of the monitoring. This configuration parameter is not used if DHCP is enabled. This is only useful if the monitoring have to use a gateway, this is generally not necessary. The default gateway is 192.168.45.1.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgNetworkDNSIfStatic 1.3.6.1.4.1.26854.3.2.1.15.3.5
The static DNS of the monitoring. This configuration parameter is used to resolve URI and server name. This is not necessary if you are only IP address as target server. The default DNS server is 192.168.45.1.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgNetworkMaxTransmissionUnit 1.3.6.1.4.1.26854.3.2.1.15.3.8
Specifies the TCP/IP MTU for the network interface
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgTimeSNTPTimeServer 1.3.6.1.4.1.26854.3.2.1.15.3.11
The address of the server acting as SNTP timer server. If this server is not valid, the monitoring cannot update automatically his time. You can use several time server by usin a coma separator without space.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgTimeTimeZoneName 1.3.6.1.4.1.26854.3.2.1.15.3.14
The Time Zone of the site
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgTimeSNTPTimeRefresh 1.3.6.1.4.1.26854.3.2.1.15.3.15
Set the time between synchronisation with the SNTP server (max 1000 hours, by default 178)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgTimeSNTPTimeRecoveryRefresh 1.3.6.1.4.1.26854.3.2.1.15.3.16
Set the time to wait before retry if a synchronisation fail (max 1000 hours, by default 24)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgWebServerWebServerSecurityEnabled 1.3.6.1.4.1.26854.3.2.1.15.3.22
This is a True/False parameter used to activate or deactivate the access control to the web server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgWebServerWebServerPort 1.3.6.1.4.1.26854.3.2.1.15.3.23
This is an unsigned integer parameter used to configure the port at which the web server is accessible. By default, the port is 80. If you change this port, you must be sure that the traffic is allowed by your switches and routers on this port.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgWebServerWebAuthenticationMethod 1.3.6.1.4.1.26854.3.2.1.15.3.24
The web access security can be managed with 3 authentication methods: Basic Access, Digest Access or Basic with Radius.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgWebServerHttpsWebServerPort 1.3.6.1.4.1.26854.3.2.1.15.3.26
This is a port number to activate or deactivate the https web server - 0 or 443 by default
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgWebServerDefaultPage 1.3.6.1.4.1.26854.3.2.1.15.3.31
The default page displayed on logon (dashboard, site, summary, alarm_event, ...)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventPostingActivated 1.3.6.1.4.1.26854.3.2.1.15.3.41
This is a True/False parameter used to activate or deactivate the XML event posting.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventPostingRefreshTime 1.3.6.1.4.1.26854.3.2.1.15.3.42
The minimal time in second between to calculation of the XML events to send. By default, this is done every two seconds.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventPostingTimeout 1.3.6.1.4.1.26854.3.2.1.15.3.43
The timeout in millisecond when trying to post XML data to a Web Server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventPostingToSecOnlyIfPrimFail 1.3.6.1.4.1.26854.3.2.1.15.3.45
If this parameter is set to true, the events will be sent to secondary only if primary server is not available. If this parameter is set to false, all the events will be sent to primary and secondary server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLTablesToPostOnXMLEvent 1.3.6.1.4.1.26854.3.2.1.15.3.46
The list of the tables to send when an event is generated. (description,alarm,data,config,control). This allows to have armada database updated on event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLHeartbeatTime 1.3.6.1.4.1.26854.3.2.1.15.3.51
This is the time between 2 XML Post of heartbeat. If set to 0, no heartbeat.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPActivated 1.3.6.1.4.1.26854.3.2.1.15.3.61
This is a True/False parameter used to activate or deactivate the SNMP agent.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPTrapVersion 1.3.6.1.4.1.26854.3.2.1.15.3.63
Traps/Notification can be sent with SNMP V1, V2c or V3 format.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPGETMinSecurityLevel 1.3.6.1.4.1.26854.3.2.1.15.3.64
4 choices are available: No Authentication, V1 Community, V2c Community or V3.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPSETMinSecurityLevel 1.3.6.1.4.1.26854.3.2.1.15.3.65
4 choices are available: No Authentication, V1 Community, V2c Community or V3.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3AuthAlgorithm 1.3.6.1.4.1.26854.3.2.1.15.3.66
3 choices are available: MD5, SHA, Any
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3PrivacyAlgorithm 1.3.6.1.4.1.26854.3.2.1.15.3.67
3 choices are available: DES, AES, 3DES
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3PrivacyPassword 1.3.6.1.4.1.26854.3.2.1.15.3.68
The global SNMP V3 Encryption Password. This one is common for all the users to avoid complexity
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3EngineID 1.3.6.1.4.1.26854.3.2.1.15.3.69
The SNMP V3 Local Engine ID string
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3TrapAuthAlgorithm 1.3.6.1.4.1.26854.3.2.1.15.3.72
2 choices are available: MD5, SHA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3TrapPrivacyAlgorithm 1.3.6.1.4.1.26854.3.2.1.15.3.73
3 choices are available: DES, AES, 3DES
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3TrapUsername 1.3.6.1.4.1.26854.3.2.1.15.3.74
The SNMP V3 Trap UserName used for all the SNMP V3 traps
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3TrapAuthPassword 1.3.6.1.4.1.26854.3.2.1.15.3.75
The SNMP V3 Trap Authentication Password
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPV3TrapPrivacyPassword 1.3.6.1.4.1.26854.3.2.1.15.3.76
The SNMP V3 Trap Privacy Password
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSiteDescriptionIdsIncludedInTraps 1.3.6.1.4.1.26854.3.2.1.15.3.77
List of site Description Elements to send on traps. (to have the site reference and the city in each trap for example). The list is separated with ';'
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgGenericGenerateEventOnConfChanges 1.3.6.1.4.1.26854.3.2.1.15.3.81
This is a True/False parameter used to activate or deactivate the tracking of configuration changes
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgDataRecordsAutoArchivePeriodDataRecord 1.3.6.1.4.1.26854.3.2.1.15.3.82
Period in hour to auto save records (when detailled and long duration records are needed). 0 means disabled.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgGenericGenerateEventOnControlExecution 1.3.6.1.4.1.26854.3.2.1.15.3.83
This is a True/False parameter used to activate or deactivate the tracking of control execution
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgGenericGenerateEventOnAlarmAcknowledge 1.3.6.1.4.1.26854.3.2.1.15.3.84
This is a True/False parameter used to activate or deactivate the tracking of alarm acknowledgment
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgInventoryRequiredCANBusNodeIDs 1.3.6.1.4.1.26854.3.2.1.15.3.91
This is a coma separated list with the required CAN bus node ids
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgInventoryLSSCANidrange 1.3.6.1.4.1.26854.3.2.1.15.3.92
By default 50-80, means up to 50 Can Nodes like rectifiers with CAN Id 50 to 80. To support up to 100 rectifiers, change it to 1-100.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgInventorySystemNodesDefinition 1.3.6.1.4.1.26854.3.2.1.15.3.93
dc3(30-100)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgInventoryLSSCANOpenSavedConf 1.3.6.1.4.1.26854.3.2.1.15.3.95
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgUsersAdministratorLoginPassword 1.3.6.1.4.1.26854.3.2.1.15.3.101
This is the login and the password of the administrator. It is saved with a special syntax. First the login in clear, followed of 2 points, followed of the MD5 hashed password. If you change the login:password by entering a non hashed password, this last is automatically hashed.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgUsersUser1LoginPassword 1.3.6.1.4.1.26854.3.2.1.15.3.102
This is the login and the password of the user number 1.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgUsersUser2LoginPassword 1.3.6.1.4.1.26854.3.2.1.15.3.103
This is the login and the password of the user number 2.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgUsersUser3LoginPassword 1.3.6.1.4.1.26854.3.2.1.15.3.104
This is the login and the password of the user number 3.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgUsersUser4LoginPassword 1.3.6.1.4.1.26854.3.2.1.15.3.105
This is the login and the password of the user number 4.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgUsersUser5LoginPassword 1.3.6.1.4.1.26854.3.2.1.15.3.106
This is the login and the password of the user number 5.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgRadiusAuthenticationRadiusServer 1.3.6.1.4.1.26854.3.2.1.15.3.111
Radius Server address. If you have a secondary server, you could use a coma to separate it.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgRadiusAuthenticationRadiusPort 1.3.6.1.4.1.26854.3.2.1.15.3.112
Radius Port. If you have a secondary server, you could use a coma to separate it.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgRadiusAuthenticationRadiusSecret 1.3.6.1.4.1.26854.3.2.1.15.3.113
Radius PassPhrase
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgEmailEnableEmailFeature 1.3.6.1.4.1.26854.3.2.1.15.3.120
Enable/Disable the email feature
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgEmailSmtpServer 1.3.6.1.4.1.26854.3.2.1.15.3.121
Smtp Server. If you are using a domain name, make sure you configured the network Dns (CF5)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgEmailSmtpDomain 1.3.6.1.4.1.26854.3.2.1.15.3.122
Smtp Domain. (Required by some servers.)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgEmailSmtpUserLoginPassword 1.3.6.1.4.1.26854.3.2.1.15.3.123
Smtp Login and Password. The password is encrypted. To enter a new login and password, enter login:password and validate, the password will be encrypted.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgEmailMailSender 1.3.6.1.4.1.26854.3.2.1.15.3.130
Mail Sender (The 'From' of the emails you will receive)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgEmailMailRecipients 1.3.6.1.4.1.26854.3.2.1.15.3.131
Mail Recipients, separated with semicolon ';'
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgEmailMinimalSeverityTypeToSendMail 1.3.6.1.4.1.26854.3.2.1.15.3.135
This is the minimal severity of the event to send a Summary Mail
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgControllerAutomaticReboot 1.3.6.1.4.1.26854.3.2.1.15.3.150
Cron rules used in order to restart automatically the controller. Before rebooting configuration, events and data records are saved.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgCloudLinkCloudEnabled 1.3.6.1.4.1.26854.3.2.1.15.3.161
Enable Cloud Connection
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgCloudLinkCloudServer 1.3.6.1.4.1.26854.3.2.1.15.3.162
Cloud Server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgCloudLinkCloudPort 1.3.6.1.4.1.26854.3.2.1.15.3.163
Cloud Port
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgCloudLinkCloudCredential 1.3.6.1.4.1.26854.3.2.1.15.3.164
Enter Credential of your AlphaCloud account in order to connect. You have to enter username:password in order to save your credential.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgCloudLinkCloudCluster 1.3.6.1.4.1.26854.3.2.1.15.3.165
Cloud Cluster
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgInventoryRS485ExtensionsConf 1.3.6.1.4.1.26854.3.2.1.15.3.210
The configuration string for RS485 Extensions
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgInventoryEthernetExtensionsConf 1.3.6.1.4.1.26854.3.2.1.15.3.220
The configuration string for Ethernet Extensions
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgScriptingEnabledscripts 1.3.6.1.4.1.26854.3.2.1.15.3.250
This parameter enable all CompasLua Scripting capabilities. You can control scripts in Files -> Files manager > scripting tab.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgScriptingNumberofErrorsbeforetriggeringalarm 1.3.6.1.4.1.26854.3.2.1.15.3.251
Number of errors before triggering the scripting error alarm. When number of error is higher than this parameter, the alarm is triggered. If 0 is set, the alarm is deactivated
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgGenericReadAccessUserNumbers 1.3.6.1.4.1.26854.3.2.1.15.3.521
The list of the user numbers which have read access to this equipment. The user numbers are coma separated. The accepted user id are 1,2,3,4 and 5. Ex: 1,3,4
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgGenericWriteAccessUserNumbers 1.3.6.1.4.1.26854.3.2.1.15.3.522
The list of the user numbers which have write access to this equipment. This means that these users can modify the configuration element, the alarm settings and use the control elements. The user numbers are coma separated. The accepted user ids are 1,2,3,4 and 5. Ex: 1,3,4
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgGenericEventTableLength 1.3.6.1.4.1.26854.3.2.1.15.3.601
The maximum length of the table. The value must be comprised between 10 and 4000
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPSNMPTrapTargetsIP 1.3.6.1.4.1.26854.3.2.1.15.3.611
One or multiple target IP to send traps, coma separated. Ex: 130.145.23.1, 130.23.12.45
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgSNMPMinimalEventSeverityForTraps 1.3.6.1.4.1.26854.3.2.1.15.3.612
This is the minimal severity of the event to send a SNMP trap
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventsPrimPostURL 1.3.6.1.4.1.26854.3.2.1.15.3.651
This is the first URL at which the events related to this equipment must be posted. The XML ETSI standard is used in the posted data content.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventsPrimPostLogin 1.3.6.1.4.1.26854.3.2.1.15.3.652
The login which must be used when posting events to the primary server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventsPrimPostPassword 1.3.6.1.4.1.26854.3.2.1.15.3.653
The password which must be used when posting events to the primary server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventsSecPostURL 1.3.6.1.4.1.26854.3.2.1.15.3.661
This is the second URL at which the events related to this equipment must be posted. The XML ETSI standard is used in the posted data content. This allows having redundancy with the management server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventsSecPostLogin 1.3.6.1.4.1.26854.3.2.1.15.3.662
The login which must be used when posting events to the secondary server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgXMLXMLEventsSecPostPassword 1.3.6.1.4.1.26854.3.2.1.15.3.663
The password which must be used when posting events to the secondary server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgPLCNumberOfPLCData 1.3.6.1.4.1.26854.3.2.1.15.3.901
The number of PLC data. Every equipment can manage up to 30 user programmable data. Data elements are automatically added in the data table. Configuration parameters are added to set the PLC Data Name and the PLC Data Mathematical calculation. In order to use these functionalities, you need a license with the 'PLC' module
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CfgPLCNumberOfPLCAlarm 1.3.6.1.4.1.26854.3.2.1.15.3.902
The number of PLC alarm. Every equipment can manage up to 30 user programmable alarms. Alarm elements are automatically added in the alarm table. The alarm parameters are added to set the PLC Alarm Name and the PLC Alarm Boolean condition. In order to use these functionalities, you need a licence with the 'PLC' module
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1Control 1.3.6.1.4.1.26854.3.2.1.16
OBJECT IDENTIFIER    

siteV1ControlNumber 1.3.6.1.4.1.26854.3.2.1.16.1
The number of entries in the Control table related to the Site
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

siteV1ControlTable 1.3.6.1.4.1.26854.3.2.1.16.2
The table of Control entries related to the Site
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SiteV1ControlEntry

siteV1ControlEntry 1.3.6.1.4.1.26854.3.2.1.16.2.1
A Control entry
Status: current Access: not-accessible
OBJECT-TYPE    
  SiteV1ControlEntry  

siteV1ControlIndex 1.3.6.1.4.1.26854.3.2.1.16.2.1.1
The Control entry Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

siteV1ControlName 1.3.6.1.4.1.26854.3.2.1.16.2.1.2
The Control entry name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

siteV1ControlValue 1.3.6.1.4.1.26854.3.2.1.16.2.1.3
The Control entry value
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1ControlEntryStatus 1.3.6.1.4.1.26854.3.2.1.16.2.1.4
The status of this table entry - not used, only for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

siteV1ControlList 1.3.6.1.4.1.26854.3.2.1.16.3
OBJECT IDENTIFIER    

siteV1CtrlControllerRebootController 1.3.6.1.4.1.26854.3.2.1.16.3.1
Writing a '1' to this control element will reboot the monitoring. Events and Records will be saved.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerSaveConfAndRebootController 1.3.6.1.4.1.26854.3.2.1.16.3.2
Writing a '1' to this control element will first save the actual configuration and will reboot the monitoring after.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerRebootControllerWithoutSavingRecords 1.3.6.1.4.1.26854.3.2.1.16.3.3
Writing a '1' to this control element will reboot the monitoring without saving records
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlNetworkApplyNetworkConf 1.3.6.1.4.1.26854.3.2.1.16.3.6
Writing a '1' to this control element will reconfigure the ethernet according to the Network Configuration. If you change the IP address in the config table without using this command after, the configuration is not applied.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlTimeForceSNTPTimeRefresh 1.3.6.1.4.1.26854.3.2.1.16.3.11
Writing a '1' to this control element will force the monitoring to try to refresh his time with the configured SNTP Time Server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlTimeSetLocalTime 1.3.6.1.4.1.26854.3.2.1.16.3.12
Writing a date and time to this control element allows to manually change the local time of the monitoring. The syntax of the date and the time is: 2007-11-19T13:02:34
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlTimeSetUTCTime 1.3.6.1.4.1.26854.3.2.1.16.3.13
Writing a date and time to this control element allows to manually change the UTC time of the monitoring. The syntax of the date and the time is: 2007-11-19T13:02:34
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlTimeResetUptime 1.3.6.1.4.1.26854.3.2.1.16.3.14
Writing a '1' to this control element will reset the uptime of the monitoring.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerCleanandSaveXMLUserConf 1.3.6.1.4.1.26854.3.2.1.16.3.20
Writing a '1' to this control element will remove the configuration sections related to missing equipments, than save all the configuration of all the connected equipment in a XML format. This file is read when the monitoring is starting in order to configure the monitoring. This file is also accessible trough the FTP server or can be downloaded trough the web interface.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerSaveXMLUserConf 1.3.6.1.4.1.26854.3.2.1.16.3.21
Writing a '1' to this control element will save all the configuration of all the connected (or previously connected) equipment in a XML format. This file is read when the monitoring is starting in order to configure the monitoring. This file is also accessible trough the FTP server or can be downloaded trough the web interface.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerSaveInventory 1.3.6.1.4.1.26854.3.2.1.16.3.22
Writing a '1' to this control element will save save the inventory in a XML format. This file is read when the monitoring is starting in order to configure the monitoring. This file is also accessible trough the FTP server or can be downloaded trough the web interface.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlDataRecordsSaveDataRecords 1.3.6.1.4.1.26854.3.2.1.16.3.33
Writing a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This function is called automatically everyday.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlDataRecordsExportDataRecordsinCSV 1.3.6.1.4.1.26854.3.2.1.16.3.34
Writing a '1' to this control element will force the monitoring to save all the CVS records files. The CSV files are stored in the records folder.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlDataRecordsArchiveDataRecords 1.3.6.1.4.1.26854.3.2.1.16.3.35
Writing a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This function is called automatically everyday.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlDataRecordsDeleteAllDataRecords 1.3.6.1.4.1.26854.3.2.1.16.3.36
Writing a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This function is called automatically everyday.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerEmulateRecords 1.3.6.1.4.1.26854.3.2.1.16.3.40
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerReloadTranslations 1.3.6.1.4.1.26854.3.2.1.16.3.41
Writing a '1' to this control element will reload all the csv translation files
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerReloadLicense 1.3.6.1.4.1.26854.3.2.1.16.3.51
Writing a '1' to this control element will reload the license file
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerManageFTPServer 1.3.6.1.4.1.26854.3.2.1.16.3.55
This Control is used to manage the FTP Server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlInventoryRemoveAbsentEquipments 1.3.6.1.4.1.26854.3.2.1.16.3.61
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlInventoryResetCANBusNode 1.3.6.1.4.1.26854.3.2.1.16.3.81
Writing a valid CAN bus node id to this control element will reset the correspondent device.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlInventorySaveCANOpenLSSConf 1.3.6.1.4.1.26854.3.2.1.16.3.82
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlInventoryStartNewInventory 1.3.6.1.4.1.26854.3.2.1.16.3.83
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlInventoryUpgradeNodeFirmware 1.3.6.1.4.1.26854.3.2.1.16.3.91
This control element is used to start the firmware upgrade of a CAN bus Node. You need to upload first the firmware trough ftp in the /user/firmware path. Then you need to write the id number of the CAN Node, followed by a coma, followed by the file name. Example : '101,SOFT_0000030_01.txt'.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlInventoryCancelFirmwareUpgrade 1.3.6.1.4.1.26854.3.2.1.16.3.92
This control element is used to cancel the running firmware upgrade of a CAN bus Node.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlFilesFlashBinary 1.3.6.1.4.1.26854.3.2.1.16.3.103
This control element is used to start a binary flash update. You need to upload first the firmware trough ftp in the /user/firmware path.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlFilesDownloadFileFromUrl 1.3.6.1.4.1.26854.3.2.1.16.3.110
This control element is used to download a file wiht HTTP get, the argument is an url. The file is saved in the upload folder
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlFilesDeleteUserUploadedFile 1.3.6.1.4.1.26854.3.2.1.16.3.111
This control element is used to delete a file in the user-upload folder. This is riskless as these files are not used, they are temporary files.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlFilesMoveUserUploadedFile 1.3.6.1.4.1.26854.3.2.1.16.3.112
This control element is used to copy a file from the user-upload folder to another one. Be aware of what your are doing !
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlFilesExtractZipFileinuserupload 1.3.6.1.4.1.26854.3.2.1.16.3.113
This control element is used to delete a file in the user-upload folder. This is riskless as these files are not used, they are temporary files.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlEmailSendSummaryEmail 1.3.6.1.4.1.26854.3.2.1.16.3.120
This control element is used to force the sending of a summary to the configured mail address
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlScriptingControlLuaScript 1.3.6.1.4.1.26854.3.2.1.16.3.250
This control element is used to control the lua scripting system. Available command are: enable[Enable Lua Capabilities], disable[Disable Lua Capabilities], restart[Restart All Lua Capabilities], refresh[Read the folder script (if you added a file when system is running)], enable filename[enable filename.lua located in folder user/scripts], disable filename[disable filename.lua located in folder user/scripts], restart filename : Restart fileName[file must be enabled], reseterrors[Reset all errors counters], reseterrors filename[Reset errors from filename
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlControllerAdvancedFunctionGenericCommandExecution 1.3.6.1.4.1.26854.3.2.1.16.3.300
This control is used to perform advanced operation.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlGenericClearMyEvents 1.3.6.1.4.1.26854.3.2.1.16.3.501
By writing '1' to this control element, all the events of this equipment will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlGenericClearAllEvents 1.3.6.1.4.1.26854.3.2.1.16.3.502
By writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlGenericAddEvent 1.3.6.1.4.1.26854.3.2.1.16.3.511
This control element adds an event of severity none. The event name is the text written to this control element
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlGenericAddMajorEvent 1.3.6.1.4.1.26854.3.2.1.16.3.512
This control element adds an event of severity major. The event name is the text written to this control element
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlGenericResetDefaultNamesAndGroups 1.3.6.1.4.1.26854.3.2.1.16.3.521
This control element resets all the element Names, Groups and Subgroups to default values for this equipment
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1CtrlGenericResetDefaultNamesAndGroupsRecursive 1.3.6.1.4.1.26854.3.2.1.16.3.522
This control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipments
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

siteV1Notifications 1.3.6.1.4.1.26854.3.2.1.18
OBJECT IDENTIFIER    

siteV1NotificationPrefix 1.3.6.1.4.1.26854.3.2.1.18.0
OBJECT IDENTIFIER    

siteV1NotificationOfEvent 1.3.6.1.4.1.26854.3.2.1.18.0.1
Notification generated when a new event appears
Status: current Access: read-write
NOTIFICATION-TYPE    

siteV1Compliance 1.3.6.1.4.1.26854.3.2.1.19
OBJECT IDENTIFIER    

siteV1ComplianceGroups 1.3.6.1.4.1.26854.3.2.1.19.1
OBJECT IDENTIFIER    

siteV1FullCompliance 1.3.6.1.4.1.26854.3.2.1.19.2
The compliance statement for SNMPV2 entities which implement the SNMPV2 MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

siteV1GlobalGroup 1.3.6.1.4.1.26854.3.2.1.19.1.1
text
Status: current Access: read-write
OBJECT-GROUP    

siteV1NotificationGroup 1.3.6.1.4.1.26854.3.2.1.19.1.2
text
Status: current Access: read-write
NOTIFICATION-GROUP    

energySystems 1.3.6.1.4.1.26854.3.2.1.20
OBJECT IDENTIFIER    

es1 1.3.6.1.4.1.26854.3.2.1.20.1
OBJECT IDENTIFIER    

es1GlobalStatus 1.3.6.1.4.1.26854.3.2.1.20.1.1
A textual string (alarms, normal or unknown) containing the status of the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

es1GlobalAlarmSeverityType 1.3.6.1.4.1.26854.3.2.1.20.1.2
The alarm severity type (critical, major, minor, warning, none, disabled) of the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1GlobalAlarmSeverityLevel 1.3.6.1.4.1.26854.3.2.1.20.1.3
The alarm severity level (0-9) of the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1GlobalAlarmSeverityTypeInt 1.3.6.1.4.1.26854.3.2.1.20.1.4
The alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1Description 1.3.6.1.4.1.26854.3.2.1.20.1.10
OBJECT IDENTIFIER    

es1DescriptionNumber 1.3.6.1.4.1.26854.3.2.1.20.1.10.1
The number of entries in the Energy System Description table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1DescriptionTable 1.3.6.1.4.1.26854.3.2.1.20.1.10.2
The Description table of the Energy System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1DescriptionEntry

es1DescriptionEntry 1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1
A Description entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1DescriptionEntry  

es1DescriptionIndex 1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.1
Description Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1DescriptionName 1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.2
Description Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1DescriptionValue 1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.3
Description Value
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

es1DescriptionEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.4
The status of this table entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1DescriptionList 1.3.6.1.4.1.26854.3.2.1.20.1.10.3
OBJECT IDENTIFIER    

es1DescDescriptionDescription 1.3.6.1.4.1.26854.3.2.1.20.1.10.3.1
A free text zone to write a system description
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1DescDescriptionReference 1.3.6.1.4.1.26854.3.2.1.20.1.10.3.2
A free text zone to write the customer reference of the system
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1Alarm 1.3.6.1.4.1.26854.3.2.1.20.1.11
OBJECT IDENTIFIER    

es1AlarmNumber 1.3.6.1.4.1.26854.3.2.1.20.1.11.1
The number of entries in the Energy System Alarm table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1AlarmTable 1.3.6.1.4.1.26854.3.2.1.20.1.11.2
The table of Alarm entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1AlarmEntry

es1AlarmEntry 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1
An alarm entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1AlarmEntry  

es1AlarmIndex 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.1
Alarm Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1AlarmName 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.2
Alarm Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1AlarmActive 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.3
Is the Alarm active ? 'true' for active, 'false' for not-active
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1AlarmSeverityType 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.4
The alarm severity type (major, minor, warning, none, disabled) of this alarm entry
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1AlarmSeverityLevel 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.5
The alarm severity level (0-9) of this alarm entry
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1AlarmStartTime 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.6
The last start time of this alarm entry (null if never active)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1AlarmStopTime 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.7
The last stop time of this alarm entry (null if alarm active)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1AlarmEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.8
The status of this table entry - not used, only for MIB compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1AlarmSummary 1.3.6.1.4.1.26854.3.2.1.20.1.11.3
Summary bit vector with all the alarms state of the Energy System. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.
Status: current Access: read-only
OBJECT-TYPE    
  BITS none(0)  

es1Event 1.3.6.1.4.1.26854.3.2.1.20.1.12
OBJECT IDENTIFIER    

es1EventNumber 1.3.6.1.4.1.26854.3.2.1.20.1.12.1
The number of entries in the Event Table related to the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1EventTable 1.3.6.1.4.1.26854.3.2.1.20.1.12.2
The Event table related to the Energy System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1EventEntry

es1EventEntry 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1EventEntry  

es1EventIndex 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.1
Event Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1EventId 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.2
Event Index
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

es1EventName 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.3
Event Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1EventDateTime 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.4
The date and time of the event
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1EventSeverityType 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.5
The event severity type ('major', 'minor', 'warning' or 'none')
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1EventSeverityLevel 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.6
The event severity level (0-9)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1EventEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.7
The status of this table entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1Data 1.3.6.1.4.1.26854.3.2.1.20.1.13
OBJECT IDENTIFIER    

es1DataNumber 1.3.6.1.4.1.26854.3.2.1.20.1.13.1
The number of entries in the Data Table related to the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1Config 1.3.6.1.4.1.26854.3.2.1.20.1.15
OBJECT IDENTIFIER    

es1ConfigNumber 1.3.6.1.4.1.26854.3.2.1.20.1.15.1
The number of entries in the Config table related to the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1ConfigTable 1.3.6.1.4.1.26854.3.2.1.20.1.15.2
The table of Config entries related to the Energy System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1ConfigEntry

es1ConfigEntry 1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1
A Config entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1ConfigEntry  

es1ConfigIndex 1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.1
The Config entry Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1ConfigName 1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.2
The Config entry name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1ConfigValue 1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.3
The Config entry value
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1ConfigEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.4
The status of this table entry - not used, only for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1ConfigList 1.3.6.1.4.1.26854.3.2.1.20.1.15.3
OBJECT IDENTIFIER    

es1CfgEnergyMeterNumberOfGenericPulseEnergyCounter 1.3.6.1.4.1.26854.3.2.1.20.1.15.3.100
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1Control 1.3.6.1.4.1.26854.3.2.1.20.1.16
OBJECT IDENTIFIER    

es1ControlNumber 1.3.6.1.4.1.26854.3.2.1.20.1.16.1
The number of entries in the Control table related to the Energy System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1ControlTable 1.3.6.1.4.1.26854.3.2.1.20.1.16.2
The table of Control entries related to the Energy System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1ControlEntry

es1ControlEntry 1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1
A Control entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1ControlEntry  

es1ControlIndex 1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.1
The Control entry Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1ControlName 1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.2
The Control entry name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1ControlValue 1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.3
The Control entry value
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1ControlEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.4
The status of this table entry - not used, only for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1ControlList 1.3.6.1.4.1.26854.3.2.1.20.1.16.3
OBJECT IDENTIFIER    

es1CtrlGenericClearMyEvents 1.3.6.1.4.1.26854.3.2.1.20.1.16.3.501
By writing '1' to this control element, all the events of this equipment will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1CtrlGenericClearAllEvents 1.3.6.1.4.1.26854.3.2.1.20.1.16.3.502
By writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1CtrlGenericAddEvent 1.3.6.1.4.1.26854.3.2.1.20.1.16.3.511
This control element adds an event of severity none. The event name is the text written to this control element
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1CtrlGenericAddMajorEvent 1.3.6.1.4.1.26854.3.2.1.20.1.16.3.512
This control element adds an event of severity major. The event name is the text written to this control element
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1CtrlGenericResetDefaultNamesAndGroups 1.3.6.1.4.1.26854.3.2.1.20.1.16.3.521
This control element resets all the element Names, Groups and Subgroups to default values for this equipment
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1CtrlGenericResetDefaultNamesAndGroupsRecursive 1.3.6.1.4.1.26854.3.2.1.20.1.16.3.522
This control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipments
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1Notifications 1.3.6.1.4.1.26854.3.2.1.20.1.18
OBJECT IDENTIFIER    

es1NotificationPrefix 1.3.6.1.4.1.26854.3.2.1.20.1.18.0
OBJECT IDENTIFIER    

es1NotificationOfEvent 1.3.6.1.4.1.26854.3.2.1.20.1.18.0.1
Notification generated when a new event appears
Status: current Access: read-write
NOTIFICATION-TYPE    

es1Compliance 1.3.6.1.4.1.26854.3.2.1.20.1.19
OBJECT IDENTIFIER    

es1ComplianceGroups 1.3.6.1.4.1.26854.3.2.1.20.1.19.1
OBJECT IDENTIFIER    

es1FullCompliance 1.3.6.1.4.1.26854.3.2.1.20.1.19.2
The compliance statement for SNMPV2 entities which implement the SNMPV2 MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

es1GlobalGroup 1.3.6.1.4.1.26854.3.2.1.20.1.19.1.1
text
Status: current Access: read-write
OBJECT-GROUP    

es1NotificationGroup 1.3.6.1.4.1.26854.3.2.1.20.1.19.1.2
text
Status: current Access: read-write
NOTIFICATION-GROUP    

es1DCSystems 1.3.6.1.4.1.26854.3.2.1.20.1.20
OBJECT IDENTIFIER    

es1dc1 1.3.6.1.4.1.26854.3.2.1.20.1.20.1
OBJECT IDENTIFIER    

es1dc1GlobalStatus 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.1
A textual string (alarms, normal or unknown) containing the status of the DC System
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

es1dc1GlobalAlarmSeverityType 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.2
The alarm severity type (critical, major, minor, warning, none, disabled) of the DC System
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1GlobalAlarmSeverityLevel 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.3
The alarm severity level (0-9) of the DC System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1GlobalAlarmSeverityTypeInt 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.4
The alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the DC System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1Description 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10
OBJECT IDENTIFIER    

es1dc1DescriptionNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.1
The number of entries in the DC System Description table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DescriptionTable 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2
The Description table of the DC System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1dc1DescriptionEntry

es1dc1DescriptionEntry 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1
A Description entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1dc1DescriptionEntry  

es1dc1DescriptionIndex 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.1
Description Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1dc1DescriptionName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.2
Description Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescriptionValue 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.3
Description Value
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

es1dc1DescriptionEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.4
The status of this table entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1dc1DescriptionList 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3
OBJECT IDENTIFIER    

es1dc1DescDescriptionDescription 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.1
A free text zone to write a system description
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionReference 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.2
A free text zone to write the customer reference of the system
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionProductName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.11
The product name of the DC system monitoring
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionHardwareReference 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.12
The hardware reference of the DC system monitoring
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionSoftwareReference 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.14
The software reference of the DC system monitoring
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionSerialNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.16
The serial number of the DC system monitoring
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionManufacturingDate 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.18
The production date of the DC system monitoring
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionDistributionModuleProductName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.31
The product name of the Electronic Distribution/LVD Module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionDistributionModuleHardwareReference 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.32
The hardware reference of the Electronic Distribution/LVD Module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionDistributionModuleSoftwareReference 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.34
The software reference of the Electronic Distribution/LVD Module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionDistributionModuleSerialNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.36
The serial number of the Electronic Distribution/LVD Module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DescDescriptionDistributionModuleManufacturingDate 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.38
The manufacturing date of the Electronic Distribution/LVD Module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1Alarm 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11
OBJECT IDENTIFIER    

es1dc1AlarmNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.1
The number of entries in the DC System Alarm table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1AlarmTable 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2
The table of Alarm entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1dc1AlarmEntry

es1dc1AlarmEntry 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1
An alarm entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1dc1AlarmEntry  

es1dc1AlarmIndex 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.1
Alarm Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1dc1AlarmName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.2
Alarm Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1AlarmActive 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.3
Is the Alarm active ? 'true' for active, 'false' for not-active
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1AlarmSeverityType 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.4
The alarm severity type (major, minor, warning, none, disabled) of this alarm entry
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1AlarmSeverityLevel 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.5
The alarm severity level (0-9) of this alarm entry
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1AlarmStartTime 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.6
The last start time of this alarm entry (null if never active)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1AlarmStopTime 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.7
The last stop time of this alarm entry (null if alarm active)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1AlarmEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.8
The status of this table entry - not used, only for MIB compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1dc1AlarmSummary 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.3
Summary bit vector with all the alarms state of the DC System. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.
Status: current Access: read-only
OBJECT-TYPE    
  BITS dCBusDCBusExtraLow(0), dCBusDCBusLow(1), dCBusDCBusHigh(2), dCBusDCBusExtraHigh(3), dCBusDCBusVoltageSenseFail(4), aCBusMainsFail(5), aCBusMainsPartialFail(6), aCBusMainsLow(7), rectifiersOneRectifierFail(9), rectifiersMoreThanOneRectifierFail(10), rectifiersMissingRectifiers(11), batBatLastTestFailed(12), batBatOnDischarge(13), lVDBatLVDRelOpen(16), batBatTempTooHigh(17), batBatTempTooLow(18), batBatTempSensorFail(19), sensorsAmbientTempTooHigh(20), sensorsAmbientTempTooLow(21), sensorsAmbientTempSensorFail(22), digInputsDistributionBreakerOpen(24), digInputsBatBreakerOpen(25), digInputsDigInput1(26), digInputsDigInput2(27), digInputsDigInput3(28), digInputsDigInput4(29)  

es1dc1Event 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12
OBJECT IDENTIFIER    

es1dc1EventNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.1
The number of entries in the Event Table related to the DC System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1EventTable 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2
The Event table related to the DC System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1dc1EventEntry

es1dc1EventEntry 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1dc1EventEntry  

es1dc1EventIndex 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.1
Event Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1dc1EventId 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.2
Event Index
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

es1dc1EventName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.3
Event Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1EventDateTime 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.4
The date and time of the event
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1EventSeverityType 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.5
The event severity type ('major', 'minor', 'warning' or 'none')
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1EventSeverityLevel 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.6
The event severity level (0-9)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1EventEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.7
The status of this table entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1dc1Data 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13
OBJECT IDENTIFIER    

es1dc1DataNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.1
The number of entries in the Data Table related to the DC System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataTable 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2
The table of Data entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1dc1DataEntry

es1dc1DataEntry 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1
A data entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1dc1DataEntry  

es1dc1DataIndex 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.1
The data index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1dc1DataName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.2
The data name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DataValue 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.3
The data value
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1DataEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.4
The status of this table entry - not used, only present for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1dc1DataList 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3
OBJECT IDENTIFIER    

es1dc1DataSystemDCMode 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.1
The DC system can have 5 values: 'Float'(0), 'Equalize'(1), 'Battery Test'(2), 'Ac Failure'(3) or 'Safe'(5)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSystemPreviousDCMode 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.2
The previous value of the DC Mode : 'Float'(0), 'Equalize'(1), 'Battery Test'(2), 'Ac Failure'(3) or 'Safe'(5)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSystemNiMHChargeMode 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.5
NA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataDCBusBusVoltage 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.11
The DC bus voltage in volt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSystemRatioDeliveredOnAvailablePower 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.12
This is the ratio of the delivered power divided by the installed power, in %.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataACBusMinutesSinceLastACFailBegin 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.13
The number of minute since the last AC Failure begin
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataACBusMinutesSinceLastACFailEnd 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.14
The number of minute since the last AC Failure end
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersRectifiersOutPower 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.21
The sum of the delivered rectifier power
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersRectifiersOutCurrent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.22
The sum of the delivered rectifier current
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersRectifiersOutPowerMax 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.23
The sum of the deliverable rectifier power
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersRectifiersOutCurrentMax 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.24
The sum of the deliverable rectifier current
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfRectifierMax 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.31
The maximum possible number of rectifier in this dc system
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfPresentRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.32
The actual number of present rectifier in this dc system
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfAbsentRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.33
The actual number of absent rectifier in this dc system
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfActiveRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.34
The actual number of active rectifier in this dc system. An active rectifier is a rectifier which is present, DC OK, AC OK and not in remote off.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfACFailRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.35
The actual number or rectifier in AC Failure.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfDCFailRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.36
The actual number or rectifier with DC Failure.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfRemoteOffRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.37
The actual number or rectifier in remote off.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRectifiersNumberOfOverTempRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.38
The actual number or rectifier in Over Temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataLoadLoadPower 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.51
Estimation of the load power consumption
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataLoadLoadCurrent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.52
Estimation of the load current consumption
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatBatInputCurrent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.61
Measurement of the battery input current. A negative value means that the battery is discharging
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatBatInputPower 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.62
Measurement of the battery input power. A negative value means that the battery is discharging
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatBatTemp 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.71
The battery temperature
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatBatTestState 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.72
This is about the result of the last battery test. 10 values are possible : 'Never Tested'(0), 'Success'(1), 'On Going'(2), 'Failed: Timeout'(3), 'Failed: Vbus Too Low'(4), 'Failed: Load Too Low'(5), 'Failed: Ac Failure'(6), 'Failed: Canceled' (7), 'Failed: Lvd Opened'(8), 'Failed: No Battery'(9)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatLastBatTestDischargedCapacityRatio 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.73
This is the battery capacity, in percent, discharged during the last battery test. This value is updated at the end of the battery test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatLastBatTestDischargedCapacity 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.74
This is the battery capacity, in ampere hour, discharged during the last battery test. This value is updated at the end of the battery test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatLastBatTestFinalVoltage 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.75
This is the bus voltage at the end of the last battery test. This value is updated at the end of the battery test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatBatTestDuration 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.76
The duration of the last battery test. This value is updated at the end of the battery test. This value can't be higher than 1440 minutes (24 hours).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatPreviousBatTestDischargedCapacityRatio 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.77
This is the battery capacity, in percent, discharged during the previous battery test. This value is shifted at the end of the battery test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatPreviousBatTestDischargedCapacity 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.78
This is the battery capacity, in ampere hour, discharged during the previous battery test. This value is shifted at the end of the battery test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatPreviousBatTestFinalVoltage 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.79
This is the bus voltage at the end of the previous battery test. This value is shifted at the end of the battery test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatPreviousBatTestDuration 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.80
The duration of the previous battery test. This value is shifted at the end of the battery test. This value can't be higher than 1440 minutes (24 hours).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatPreviousBatTestState 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.81
The result of the previous battery test - 10 values are possible: 'Never Tested'(0), 'Success'(1), 'On Going'(2), 'Failed: Timeout'(3), 'Failed: Vbus Too Low'(4), 'Failed: Load Too Low'(5), 'Failed: Ac Failure'(6), 'Failed: Canceled', 'Failed: Lvd Opened'(8), 'Failed: No Battery'(9)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatMinutesSinceLastTestBat 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.82
The number of minute since the end of last battery test
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatNextScheduledBatTest 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.84
The date and time of the next time the scheduled battery test will run
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatBatChargeCapacity 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.91
The battery charge capacity, calculated by integration of the current.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatCalculatedAutonomy 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.92
Calculation of the remaining autonomy. This value can change following the load of your system and the maximal depth of dicharge configuration (CF39).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataBatBatCurrentIntegration 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.94
Actual value of the integration of the current, in Ampere * hour
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataLVDLVDState 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.101
Actual state of the LVD
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRelsRel1State 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.111
Actual state of the Relay 1
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRelsRel2State 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.112
Actual state of the Relay 2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRelsRel3State 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.113
Actual state of the Relay 3
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataRelsRel4State 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.114
Actual state of the Relay 3
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSmartEnergyEfficiencyOptimizedNumberOfRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.121
The optimal number of ON rectifier for Efficiency Optimization
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSmartEnergySystemLossWithoutOptimisation 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.122
Estimation of the losses without optimisation
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSmartEnergySystemLossWithOptimisation 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.123
Estimation of the losses with optimisation
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSmartEnergyRectifierModelUsedForCalculation 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.124
The rectifier model used
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSmartEnergySmartEnergySavings 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.125
Estimation of the losses with optimisation
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSensorsAmbientTemp 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.151
The ambiant temperature (second temperature sense)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1DataSensorsPulseCounter4 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.204
The counter value of the digital input 4.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1Config 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15
OBJECT IDENTIFIER    

es1dc1ConfigNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.1
The number of entries in the Config table related to the DC System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1ConfigTable 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2
The table of Config entries related to the DC System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1dc1ConfigEntry

es1dc1ConfigEntry 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1
A Config entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1dc1ConfigEntry  

es1dc1ConfigIndex 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.1
The Config entry Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1dc1ConfigName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.2
The Config entry name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1ConfigValue 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.3
The Config entry value
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1ConfigEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.4
The status of this table entry - not used, only for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1dc1ConfigList 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3
OBJECT IDENTIFIER    

es1dc1CfgDCBusDCBusFloatVoltageat25degC 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.1
The floating dc bus voltage of the system at 25 Celsius degree
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageExtraLow 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.2
The bus voltage under which the alarm 'DC Bus Voltage Extra Low' is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageExtraLowHysteresis 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.3
The voltage hysteresis on the alarm 'DC Bus Voltage Extra Low'.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageLow 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.4
The bus voltage under which the alarm 'DC Bus Voltage Low' is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageLowHysteresis 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.5
The voltage hysteresis on the alarm 'DC Bus Voltage Low
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageHigh 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.6
The bus voltage over which the alarm 'DC Bus Voltage High' is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageHighHysteresis 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.7
The voltage hysteresis on the alarm 'DC Bus Voltage High
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageExtraHigh 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.8
The bus voltage over which the alarm 'DC Bus Voltage Extra High' is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDCBusDCBusVoltageExtraHighHysteresis 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.9
The voltage hysteresis on the alarm 'DC Bus Voltage Extra High
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgLVDLVDDisconnectVoltage 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.10
The dc bus voltage under which the battery must be disconnected of the bus. This allows preserving the battery life. The load will be unpowered. This value has to be lower than the Battery test end voltage (CF70)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgLVDLVDDisconnectDelay 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.11
The delay in second before disconnecting the battery if the dc bus voltage is under the configured disconnected voltage. This avoids disconnection during a low bus transient.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatTempCompensationSlope 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.21
The slope of the battery temperature compensation in mv/degree. For a 48V system, -72mV/degree is often used.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatMaxPosTempCompensation 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.22
The maximal allowed positive compensation.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatMaxNegTempCompensation 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.23
The maximal allowed negative compensation.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgRectifiersMinimalNumberOfPresentRectifiers 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.25
The minimal number of rectifier which must be present. If there is less present rectifiers, the alarm 'Missing Rectifiers' is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgRectifiersRectifierModel 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.26
The rectifier model
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgRectifiersForcedRemoteOffRectifers 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.27
A list of rectifier which are forced in remote off. The id of the rectifier must be coma separated. Ex: 1,3 will maintain rectifier 1 and 3 off.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatChargeCurrentLimit 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.31
The maximal battery current when the battery is charging. The monitoring regulates the bus voltage in order to satisfy this condition. This parameter is often equal to the nominal battery capacity divided by 10.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatStringCapacity 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.32
The battery capacity in Ah.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTempLow 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.33
The temperature under which the alarm 'Battery Temperature Too Low' must be set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTempHigh 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.34
The temperature over which the alarm 'Battery Temperature Too High' must be set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTempHysteresis 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.35
The hysteresis on the 'Battery Temperature Too High' and 'Battery Temperature Too Low' alarms.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatMinimalCurrentForDischargingAlarm 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.36
The minimal discharging current to set the 'Battery On Discharge' alarm.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatCurrentHysteresisForDischargingAlarm 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.37
The hysteresis on the 'Battery On Discharge' alarm.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatPeukertNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.38
The Peukert number relates to the internal resistance of a battery and provides an indication of the excpected capacity. The ideal number is 1. This value can be calculated with the formula: (ln(t2)-ln(t1))/(ln(i1)-ln(i2)) where tx is the autonomy in hours at a constant discharge current of ix Amps. Often, we use t1 = 1h and t2 = 10h
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatMaxDepthOfDischargeforAutonomyEstimation 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.39
It is generally recommended to discharge maximum 60% of the battery capacity to enhance battery lifetime. By default, 100% is used for autonomy calculation. This parameter can also be used to take into account the age of the battery
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBoostAutomatic 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.51
The boost mode must be automatically after the fact that during a mains failure, the bus voltage went under the configured 'Boost Activation Low Voltage'. This allows charging the battery faster.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBoostActivationLowVoltage 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.52
The voltage under which the boost mode can be activated.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBoostTerminationVoltage 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.53
The voltage over which the system must go back to floating mode.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBoostTerminationCurrent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.54
The battery charging current under which the system must go back to floating mode.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBoostTerminationTime 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.55
The time in minute after which the system must go back in floating mode.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestType 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.69
Type of the battery test:
Capacity based: The battery must give the requested capacity before falling lower than a value
Time Based: The battery must sustain a defined load during a defined time.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestEndVoltage 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.70
The voltage at which any battery test must be stopped. This value has to be higher than the LVD Disconnect voltage (CF10)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestDischargeRatio 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.71
The ratio of the battery capacity to discharge. If 30 is set, 30% of the battery will be discharged during the test
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestInterval 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.72
The number of days between two automatically started battery test. If this parameter is set to 0, the battery test is not started automatically. The user can remotely or locally start or force this test.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestDischargeCurrent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.73
The current at which the battery must be discharged during a battery test. The monitoring regulates the bus voltage in order to satisfy this condition. The load current must be of course higher than this parameter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestMinimalDischargeCurrent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.74
The battery current under which the battery test must be stopped because the load is too low.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestDuration 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.75
The timeout in minute after which the battery test must be stopped.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestRequMinutesWithoutMainsFail 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.76
The minimal time in minute without mains failure in order to allow a battery start. This parameter is not taken into account when the battery test is forced.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgBatBatTestSchedulerCronRule 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.77
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgSmartEnergySmartEnergyBooleanCond 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.83
This is the boolean condition which allows or not to automatically optimize the number of rectifier in remote off.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgLVDBatLVDNodeId 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.86
This is a list of the node id of the Smart Electronic LVDs, coma separated
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput1Name 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.91
The name of the digital input 1
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput1NormallyClosed 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.92
True/False value defining if the digital input 1 is normally closed. If this digital input is not in this default state, the related alarm is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput2Name 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.93
The name of the digital input 2
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput2NormallyClosed 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.94
True/False value defining if the digital input 2 is normally closed. If this digital input is not in this default state, the related alarm is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput3Name 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.95
The name of the digital input 3
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput3NormallyClosed 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.96
True/False value defining if the digital input 3 is normally closed. If this digital input is not in this default state, the related alarm is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput4Name 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.97
The name of the digital input 4
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput4NormallyClosed 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.98
True/False value defining if the digital input 4 is normally closed. If this digital input is not in this default state, the related alarm is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput5Name 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.99
The name of the digital input 5
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput5NormallyClosed 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.100
True/False value defining if the digital input 5 is normally closed. If this digital input is not in this default state, the related alarm is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput6Name 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.101
The name of the digital input 6
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgDigInputsDigInput6NormallyClosed 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.102
True/False value defining if the digital input 6 is normally closed. If this digital input is not in this default state, the related alarm is set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgRelsDryAlarm1AlternativeBooleanCond 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.111
Another Boolean condition to activate the dry alarm relay 1. The way to define boolean condition is detailed in the PLC chapter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgRelsDryAlarm2AlternativeBooleanCond 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.112
Another Boolean condition to activate the dry alarm relay 2. The way to define boolean condition is detailed in the PLC chapter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgRelsDryAlarm3AlternativeBooleanCond 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.113
Another Boolean condition to activate the dry alarm relay 3. The way to define boolean condition is detailed in the PLC chapter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgRelsDryAlarm4AlternativeBooleanCond 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.114
Another Boolean condition to activate the dry alarm relay 4. The way to define boolean condition is detailed in the PLC chapter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgSensorsAmbientTempLow 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.131
The temperature under which the alarm 'Ambiant Temperature Too Low' must be set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgSensorsAmbientTempHigh 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.132
The temperature under which the alarm 'Ambiant Temperature Too Low' must be set.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgSensorsAmbientTempHysteresis 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.133
The hysteresis on the 'Battery Temperature Too High' and 'Battery Temperature Too Low' alarms.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgGenericReadAccessUserNumbers 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.521
The list of the user numbers which have read access to this equipment. The user numbers are coma separated. The accepted user id are 1,2,3,4 and 5. Ex: 1,3,4
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgGenericWriteAccessUserNumbers 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.522
The list of the user numbers which have write access to this equipment. This means that these users can modify the configuration element, the alarm settings and use the control elements. The user numbers are coma separated. The accepted user ids are 1,2,3,4 and 5. Ex: 1,3,4
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgGenericEventTableLength 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.601
The maximum length of the table. The value must be comprised between 10 and 4000
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgGenericEventTableLengthByRectifier 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.602
The maximum length of the table. The value must be comprised between 10 and 4000
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgPLCNumberOfPLCData 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.901
The number of PLC data. Every equipment can manage up to 30 user programmable data. Data elements are automatically added in the data table. Configuration parameters are added to set the PLC Data Name and the PLC Data Mathematical calculation. In order to use these functionalities, you need a license with the 'PLC' module
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CfgPLCNumberOfPLCAlarm 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.902
The number of PLC alarm. Every equipment can manage up to 30 user programmable alarms. Alarm elements are automatically added in the alarm table. The alarm parameters are added to set the PLC Alarm Name and the PLC Alarm Boolean condition. In order to use these functionalities, you need a licence with the 'PLC' module
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1Control 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16
OBJECT IDENTIFIER    

es1dc1ControlNumber 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.1
The number of entries in the Control table related to the DC System
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

es1dc1ControlTable 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2
The table of Control entries related to the DC System
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Es1dc1ControlEntry

es1dc1ControlEntry 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1
A Control entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Es1dc1ControlEntry  

es1dc1ControlIndex 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.1
The Control entry Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

es1dc1ControlName 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.2
The Control entry name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

es1dc1ControlValue 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.3
The Control entry value
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1ControlEntryStatus 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.4
The status of this table entry - not used, only for compliance
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

es1dc1ControlList 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3
OBJECT IDENTIFIER    

es1dc1CtrlSystemBackToFloat 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.1
The dc system must go back in floating mode.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlSystemStartBatTest 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.2
The dc system must start a battery test.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlSystemForceBatTest 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.3
The dc system must force a battery test.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlSystemStartBoostMode 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.4
The dc system must go in boost mode.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlLVDOpenTheLVD 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.11
Try to open the LVD. It could not work if the LVD is electronic, and the request will be canceled after 15 sec.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlLVDCloseTheLVD 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.12
The LVD must be closed
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlBatCorrectBatCurrentOffset 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.21
NA
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlBatResetLastBatTestState 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.41
Reset the state of the last battery test. If an alarm 'Battery Last Test Failed' is set, the alarm will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlSaveSaveConfInMCU 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.51
Save configuration parameters in the MCU microcontroller. If comp@s is not present, the system will be correctly managed.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlAdvancedSetMCUSpecificConfId 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.55
This control allows to reconfigure the MCU to support specific hardware configuration, with embedded distribution for example
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlDigInputsSetDigInput4CounterValue 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.61
Set Counter Value
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlRelsInvertRel1StateForXSeconds 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.111
Generate Pulse on relay 1
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlRelsInvertRel2StateForXSeconds 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.112
Generate Pulse on relay 2
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlRelsInvertRel3StateForXSeconds 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.113
Generate Pulse on relay 3
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlRelsInvertRel4StateForXSeconds 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.114
Generate Pulse on relay 4
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlGenericClearMyEvents 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.501
By writing '1' to this control element, all the events of this equipment will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlGenericClearAllEvents 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.502
By writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlGenericAddEvent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.511
This control element adds an event of severity none. The event name is the text written to this control element
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlGenericAddMajorEvent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.512
This control element adds an event of severity major. The event name is the text written to this control element
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlGenericResetDefaultNamesAndGroups 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.521
This control element resets all the element Names, Groups and Subgroups to default values for this equipment
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1CtrlGenericResetDefaultNamesAndGroupsRecursive 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.522
This control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipments
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

es1dc1Notifications 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18
OBJECT IDENTIFIER    

es1dc1NotificationPrefix 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18.0
OBJECT IDENTIFIER    

es1dc1NotificationOfEvent 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18.0.1
Notification generated when a new event appears
Status: current Access: read-write
NOTIFICATION-TYPE    

es1dc1Compliance 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19
OBJECT IDENTIFIER    

es1dc1ComplianceGroups 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1
OBJECT IDENTIFIER    

es1dc1FullCompliance 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.2
The compliance statement for SNMPV2 entities which implement the SNMPV2 MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

es1dc1GlobalGroup 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1.1
text
Status: current Access: read-write
OBJECT-GROUP    

es1dc1NotificationGroup 1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1.2
text
Status: current Access: read-write
NOTIFICATION-GROUP    

extensions 1.3.6.1.4.1.26854.3.2.1.21
OBJECT IDENTIFIER    

es1InverterSystems 1.3.6.1.4.1.26854.3.2.1.20.1.25
OBJECT IDENTIFIER    

es1RemotePowerFeedingSystems 1.3.6.1.4.1.26854.3.2.1.20.1.28
OBJECT IDENTIFIER