esPointEntry |
1.3.6.1.4.1.3052.12.1.1.1.1 |
Entry for EventSensor point table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ESPoint |
|
|
deStatusEntry |
1.3.6.1.4.1.3052.12.1.2.1.1 |
EventSensor status entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DEStatus |
|
|
modemCLIDLogEntry |
1.3.6.1.4.1.3052.12.1.4.1 |
Entry for table of CLID log entries |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ModemCLIDLogConfig |
|
|
pdnEntry |
1.3.6.1.4.1.3052.12.1.5.4.1.1 |
Entry for table of power distribution objects arranged according
to next-generation methodology (i.e., using multiple PowerBoss
power distributors in addition to the on-board power
distributor). |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PowerDistribNextGen |
|
|
pdnMainCurrentInEventState |
1.3.6.1.4.1.3052.12.1.5.4.1.1.4 |
The event state of the current (i.e. Amps) event of the power distributor
specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
'Very High'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
pdnMainCurrentValue |
1.3.6.1.4.1.3052.12.1.5.4.1.1.5 |
The current drawn, in mA, for the power distributor specified by pdnIndexPD.
If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss)
and refers to the current drawn by that PowerBoss and all equipment powered
by that PowerBoss. pdnIndexOutput should be 1 for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainCurrentValueStr |
1.3.6.1.4.1.3052.12.1.5.4.1.1.6 |
Essentially pdnMainCurrentValue formatted as a string in units of Amps, with
3 decimal places. pdnIndexOutput should be 1 for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
pdnMainCurrentDeadband |
1.3.6.1.4.1.3052.12.1.5.4.1.1.7 |
The deadband, in mA, for the main current sensor for the power distributor
specified by pdIndexPD. pdnIndexOutput should be 1 for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainCurrentVHighCurrent |
1.3.6.1.4.1.3052.12.1.5.4.1.1.8 |
The current, in mA, for the main current sensor's Very High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainCurrentHighCurrent |
1.3.6.1.4.1.3052.12.1.5.4.1.1.9 |
The current, in mA, for the main current sensor's High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainCurrentLowCurrent |
1.3.6.1.4.1.3052.12.1.5.4.1.1.10 |
The current, in mA, for the main current sensor's Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainCurrentVLowCurrent |
1.3.6.1.4.1.3052.12.1.5.4.1.1.11 |
The current, in mA, for the main current sensor's Very Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainVoltageInEventState |
1.3.6.1.4.1.3052.12.1.5.4.1.1.12 |
The event state of the voltage event of the power distributor
specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
'Very High'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
pdnMainVoltageValue |
1.3.6.1.4.1.3052.12.1.5.4.1.1.13 |
The voltage, in mV, at the power distributor specified by pdnIndexPD.
If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and
refers to the voltage at that PowerBoss and all equipment powered by that
PowerBoss. pdnIndexOutput should be 1 for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainVoltageValueStr |
1.3.6.1.4.1.3052.12.1.5.4.1.1.14 |
Essentially pdnMainVoltageValue formatted as a string in units of Volts, with
3 decimal places. pdnIndexOutput should be 1 for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
pdnMainVoltageDeadband |
1.3.6.1.4.1.3052.12.1.5.4.1.1.15 |
The deadband, in mV, for the main voltage sensor for the power distributor
specified by pdIndexPD. pdnIndexOutput should be 1 for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainVoltageVHighVoltage |
1.3.6.1.4.1.3052.12.1.5.4.1.1.16 |
The voltage, in mA, for the main voltage sensor's Very High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainVoltageHighVoltage |
1.3.6.1.4.1.3052.12.1.5.4.1.1.17 |
The voltage, in mV, for the main voltage sensor's High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainVoltageLowVoltage |
1.3.6.1.4.1.3052.12.1.5.4.1.1.18 |
The voltage, in mV, for the main voltage sensor's Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainVoltageVLowVoltage |
1.3.6.1.4.1.3052.12.1.5.4.1.1.19 |
The voltage, in mV, for the main voltage sensor's Very Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainPowerValue |
1.3.6.1.4.1.3052.12.1.5.4.1.1.20 |
The power, in Watts, for the power distributor specified by pdIndexPD.
pdnIndexOutput should be 1 for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pdnMainPowerValueStr |
1.3.6.1.4.1.3052.12.1.5.4.1.1.21 |
The power, in Watts, for the power distributor specified by pdIndexPD,
formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1
for this object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
pdnMainCombinedStatus |
1.3.6.1.4.1.3052.12.1.5.4.1.1.32 |
Combined status string intended to be parsed by NMS:
format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
fsStatusEntry |
1.3.6.1.4.1.3052.12.1.6.1.1 |
Fuel sensor status table entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FSStatus |
|
|
acpmStatusEntry |
1.3.6.1.4.1.3052.12.1.8.1.1 |
AC power monitor status table entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ACPMStatus |
|
|
esEntry |
1.3.6.1.4.1.3052.12.2.1.2.1 |
Table entry for EventSensor table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ESExist |
|
|
esPointConfigTempEntry |
1.3.6.1.4.1.3052.12.2.2.1.1 |
Entry for EventSensor point config temperature table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ESPointConfigTemp |
|
|
esPointConfigCCEntry |
1.3.6.1.4.1.3052.12.2.2.2.1 |
Entry for EventSensor point config contact closure table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ESPointConfigCC |
|
|
esPointConfigHumidEntry |
1.3.6.1.4.1.3052.12.2.2.3.1 |
Entry for EventSensor point config humidity table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ESPointConfigHumid |
|
|
esPointConfigAIEntry |
1.3.6.1.4.1.3052.12.2.2.5.1 |
Entry for EventSensor point config analog input table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ESPointConfigAnalogInput |
|
|
esPointConfigOutputEntry |
1.3.6.1.4.1.3052.12.2.2.6.1 |
Entry for EventSensor point config output table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ESPointConfigOutput |
|
|
portConfigEntry |
1.3.6.1.4.1.3052.12.2.3.2.1 |
Port config entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PortConfig |
|
|
portConfigMLRStartField1Text |
1.3.6.1.4.1.3052.12.2.3.2.1.15 |
Text to match MLR start field 1 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
portConfigMLRStartField2Text |
1.3.6.1.4.1.3052.12.2.3.2.1.17 |
Text to match MLR start field 2 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
portConfigMLREndField1Text |
1.3.6.1.4.1.3052.12.2.3.2.1.22 |
Text to match MLR end field 1 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
portConfigMLREndField2Text |
1.3.6.1.4.1.3052.12.2.3.2.1.24 |
Text to match MLR end field 2 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
dnsEntry |
1.3.6.1.4.1.3052.12.2.4.3.1 |
DNS server address entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DNSConfig |
|
|
hostEntry |
1.3.6.1.4.1.3052.12.2.4.5.1 |
Static host entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HostConfig |
|
|
snmpAgentEnable |
1.3.6.1.4.1.3052.12.2.4.8.1 |
ON/OFF for snmp agent |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ftpPushPushFileEntry |
1.3.6.1.4.1.3052.12.2.4.9.8.1 |
Entry for table of files to push |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FTPPushPushFileConfig |
|
|
ftpPushRemoteFileEntry |
1.3.6.1.4.1.3052.12.2.4.9.11.1 |
Entry for table of remote names of files to push |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FTPPushRemoteFileConfig |
|
|
ipRestrictionEntry |
1.3.6.1.4.1.3052.12.2.4.12.1.1.1 |
Entry for table of IP restrictions |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IPRestrictionConfig |
|
|
rtsFileEntry |
1.3.6.1.4.1.3052.12.2.4.13.1.1 |
Entry for table of RTS files |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RTSFileConfig |
|
|
routeTestAddressEntry |
1.3.6.1.4.1.3052.12.2.4.15.3.1 |
Entry for table of RTS files |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RouteTestConfig |
|
|
emailDomain |
1.3.6.1.4.1.3052.12.2.4.17.2 |
Domain to use in recipient address |
Status: current |
Access: read-write |
OBJECT-TYPE< |