SL-SONET-MIB
File:
SL-SONET-MIB.mib (28400 bytes)
Imported modules
Imported symbols
Defined Types
SignalLabel |
|
STS path signal label -- one byte, C2, class A, is allocated to
indicate the construction of the STS SPE.
The following hex values of the C2 byte has been defined. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
sigUnequipped(0), sigEquipped(1), sigPathFloatVt(2), sigPathLoackedVt(3), sigPathAsynchDs3(4), sigPathSyntran(5), sigPathAsyncDs4na(18), sigPathAtm(19), sigPathDqdb(20), sigPathFddi(21), sigPathHdlc(22), sigPathGfp(27) |
|
SlSonetConfigEntry |
|
SEQUENCE |
|
|
|
|
slSonetConfigFrameScramble |
INTEGER |
|
|
slSonetConfigType |
INTEGER |
|
|
slSonetConfigDccSelection |
INTEGER |
|
|
slSonetResetAllCounters |
INTEGER |
|
|
slSonetPortThresholdTrapEnable |
INTEGER |
|
|
slSonetConfigSdThreshold |
INTEGER |
|
|
slSonetConfigSfThreshold |
INTEGER |
|
|
slSonetCompression |
INTEGER |
|
|
slSonetOverheadTunneling |
INTEGER |
|
|
slSonetLopBitmask |
Counter64 |
|
|
slSonetTdmTrunk |
TruthValue |
|
|
slSonetFsApply |
INTEGER |
|
|
slSonetTxLte |
INTEGER |
|
|
slSonetReceivedLte |
INTEGER |
|
|
slSonetResetPmThreshold |
INTEGER |
|
|
slSonetResetAlsParams |
INTEGER |
|
|
slSonetTransceiverType |
INTEGER |
|
|
slSonetTransceiverMedia |
INTEGER |
|
SlSonetTraceEntry |
|
SEQUENCE |
|
|
|
|
slSonetTraceMode |
INTEGER |
|
|
slSonetTraceToTransmit |
DisplayString |
|
|
slSonetTraceToExpect |
DisplayString |
|
|
slSonetTraceFailure |
TruthValue |
|
|
slSonetTraceReceived |
DisplayString |
|
SlSonetSlEntry |
|
SEQUENCE |
|
|
|
|
slSonetSlToTransmit |
SignalLabel |
|
|
slSonetSlToExpect |
SignalLabel |
|
|
slSonetSlFailure |
TruthValue |
|
|
slSonetSlReceived |
INTEGER |
|
SlSonetPosEntry |
|
SEQUENCE |
|
|
|
|
slSonetPosFcs |
Gauge32 |
|
|
slSonetPosAbort |
Gauge32 |
|
|
slSonetPosMinViolation |
Gauge32 |
|
|
slSonetPosMaxViolation |
Gauge32 |
|
|
slSonetPosRxfifoDiscard |
Gauge32 |
|
|
slSonetPosPacketReceived |
Counter64 |
|
|
slSonetPosPacketReceivedOk |
Counter64 |
|
SlSonetAlsEntry |
|
SEQUENCE |
|
|
|
|
slSonetAlsMode |
INTEGER |
|
|
slSonetLosDeclareTime |
INTEGER |
|
|
slSonetTestPulseTime |
INTEGER |
|
|
slSonetManualPulseTime |
INTEGER |
|
|
slSonetAutomaticPulseTime |
INTEGER |
|
|
slSonetAutomaticDelayTime |
INTEGER |
|
|
slSonetLaserTestActivate |
INTEGER |
|
|
slSonetLaserManualActivate |
INTEGER |
|
SlSonetFsEntry |
|
SEQUENCE |
|
|
|
|
slSonetFsIfIndex |
InterfaceIndex |
|
|
slSonetFsSts |
INTEGER |
|
|
slSonetFsWidth |
INTEGER |
|
|
slSonetFsFullPathTermination |
TruthValue |
|
|
slSonetFsGranularity |
INTEGER |
|
Defined Values
slSonetMib |
1.3.6.1.4.1.4515.1.6 |
This MIB module describes the SiteLight SONET Service.
The mib contains the extensions required for the rfc2558. |
MODULE-IDENTITY |
|
|
|
slSonetOh |
1.3.6.1.4.1.4515.1.6.2 |
OBJECT IDENTIFIER |
|
|
|
slSonetPos |
1.3.6.1.4.1.4515.1.6.6 |
OBJECT IDENTIFIER |
|
|
|
slSonetAls |
1.3.6.1.4.1.4515.1.6.7 |
OBJECT IDENTIFIER |
|
|
|
slSonetFs |
1.3.6.1.4.1.4515.1.6.8 |
OBJECT IDENTIFIER |
|
|
|
slSonetConfigTable |
1.3.6.1.4.1.4515.1.6.1.1 |
The SONET/SDH configuration table. This table has objects
for configuring sonet lines. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SlSonetConfigEntry |
|
slSonetConfigEntry |
1.3.6.1.4.1.4515.1.6.1.1.1 |
An entry in the table. There is an entry for each SONET line
in the table. Entries are automatically created for an
ifType value of sonet(39). 'ifAdminStatus' from the ifTable
must be used to enable or disable a line. By default, the
line state is down. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SlSonetConfigEntry |
|
|
slSonetConfigFrameScramble |
1.3.6.1.4.1.4515.1.6.1.1.1.1 |
This object is used to disable or enable the Scrambling
option in SONET line. Please refer to GR-253-CORE for
frame scrambling. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabled(2) |
|
slSonetConfigType |
1.3.6.1.4.1.4515.1.6.1.1.1.2 |
This object represents the configured line type for Trunks:
sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk)
sonetSts192c(12) - 1 x Sts192 (10Gb Trunk)
sonetStsOther(13) - for OC-n interfaces see slSonetFsTable. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
sonetSts3(1), sonetSts3c(2), sonetSts12(3), sonetSts12c(4), sonetSts48c(5), sonetSts3cx4(6), sonetSts48(7), sonetSts3cx16(8), sonetSts3x16(9), sonetSts12cx4(10), sonetSts12x4(11), sonetSts192c(12), sonetStsOther(13) |
|
slSonetConfigDccSelection |
1.3.6.1.4.1.4515.1.6.1.1.1.3 |
This object selects the DCC type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
sonetLineDcc(1), sonetSectionDcc(2), sonetInband(3) |
|
slSonetResetAllCounters |
1.3.6.1.4.1.4515.1.6.1.1.1.4 |
Setting this variable to 1 will cause all of the counters
(performance regsters) on this SONET interface to be initialized
to zero (0). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
resetCounters(1) |
|
slSonetPortThresholdTrapEnable |
1.3.6.1.4.1.4515.1.6.1.1.1.5 |
This variable indicates whether threshold traps
should be generated for this SONET interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
slSonetConfigSdThreshold |
1.3.6.1.4.1.4515.1.6.1.1.1.6 |
This object contains the Bit Error Rate threshold for
Signal Degrade detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to -n where n is between 5 and 9
(read-write). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
5..9 |
|
slSonetConfigSfThreshold |
1.3.6.1.4.1.4515.1.6.1.1.1.7 |
This object contains the Bit Error Rate threshold for
Signal Fault detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to the -n, where n is between 3 and 5.
(read-write) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
3..5 |
|
slSonetCompression |
1.3.6.1.4.1.4515.1.6.1.1.1.9 |
This object applies only for trunk ports.
It specifies if the packets should be compressed.
0 - Means no POS compression,
1 - Means POS compression with CRC-32.
2 - Means POS compression with CRC-16.
Note that the two connected trunks should be configured
to the same value.
Note also that the BW calculation of the OC-n should
be changed according to this value. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
uncompress(0), posCompress32(1), posCompress16(2) |
|
slSonetOverheadTunneling |
1.3.6.1.4.1.4515.1.6.1.1.1.10 |
The section and line overhead tunneling configuration:
none(0) - no tunneling support
lineDcc(1) - line DCC tunneling
k1k2(2) - line DCC + protection k byte
full(3) - all transport overhead bytes are tunneled |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), lineDcc(1), k1k2(2), full(3) |
|
slSonetLopBitmask |
1.3.6.1.4.1.4515.1.6.1.1.1.11 |
The LOP status. Each bit of the bits represent the status
of the LOP alarm in corresponding STS.
For a path with more than a single STS, only the value of the
first STS in the path is relevant.
This object is relevant only for the OC-N cards and not
for the Trunk.
In the next future this object will be replaced with
an object of a new table that shall describe the OC-N
frame structure. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
slSonetTdmTrunk |
1.3.6.1.4.1.4515.1.6.1.1.1.12 |
This object is applicable only to the OC-n ports.
TRUE - means that the OC-n port is used as a TDM Trunk.
FLASE - means normal OC-n port. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
slSonetFsApply |
1.3.6.1.4.1.4515.1.6.1.1.1.13 |
Writing to this object activate the slSonetFsTable setting.
This allow the NMS to do many changes to the slSonetFsTable
and then APPLY them at once. This prevent from going through
unconsistent steps.
This object always returns the value 0. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
slSonetTxLte |
1.3.6.1.4.1.4515.1.6.1.1.1.14 |
The SS bits to transmit (bits 5,6 in H1,H1*). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ssb00(1), ssb10(2), auto(5) |
|
slSonetReceivedLte |
1.3.6.1.4.1.4515.1.6.1.1.1.15 |
The detected LTE type, according to the received SS bits
(bits 5,6 in H1,H1*). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ssb00(1), ssb10(2), ssb01(3), ssb11(4), ssbinv(5) |
|
slSonetResetPmThreshold |
1.3.6.1.4.1.4515.1.6.1.1.1.16 |
Setting this variable to 1 will reset the PM threshold
parameters to the factory defaults. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
resetCounters(1) |
|
slSonetResetAlsParams |
1.3.6.1.4.1.4515.1.6.1.1.1.17 |
Setting this variable to 1 will reset the ALS
parameters to the factory defaults. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
resetCounters(1) |
|
slSonetTransceiverType |
1.3.6.1.4.1.4515.1.6.1.1.1.18 |
The tranceiver type. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), shortWave(2), longWave(3) |
|
slSonetTraceTable |
1.3.6.1.4.1.4515.1.6.2.1.1 |
The SONET/SDH Trace table. This table contains
objects for tracing the sonet section and path. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SlSonetTraceEntry |
|
slSonetTraceEntry |
1.3.6.1.4.1.4515.1.6.2.1.1.1 |
An entry in the trace table. Entries exist for active sonet
interfaces. The objects in this table are used to verify
continued connection between the two ends of the line. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SlSonetTraceEntry |
|
|
slSonetTraceMode |
1.3.6.1.4.1.4515.1.6.2.1.1.1.1 |
Determine the Trace Message Mode. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2), monitoring(3) |
|
slSonetTraceToTransmit |
1.3.6.1.4.1.4515.1.6.2.1.1.1.2 |
Sonet Trace To Transmit. This is string that
is transmitted to perform Sonet trace
diagnostics. The trace string is repetitively
transmited so that a trace receiving terminal can
verify its continued connection to the intended
transmitter. The default value is a zero-length string.
Unless this object is set to a non-zero length string,
tracing will not be performed.
The Agent is responsible to pad the end of the string with . |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..62) |
|
slSonetTraceToExpect |
1.3.6.1.4.1.4515.1.6.2.1.1.1.3 |
Sonet Trace Massage To Expect. The receiving terminal
verifies if the incoming string matches this string.
The value of 'slSonetTraceFailure' indicates whether a
trace mismatch occurred. The default value is a
zero-length string.
The Agent is responsible to pad the end of the string with . |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..62) |
|
slSonetTraceFailure |
1.3.6.1.4.1.4515.1.6.2.1.1.1.4 |
The value of this object is set to 'true' when Sonet
Section received trace does not match the
'slSonetTraceToExpect'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
slSonetTraceReceived |
1.3.6.1.4.1.4515.1.6.2.1.1.1.5 |
This object is used to view the Sonet Trace Message that
is received by the receiving terminal.
The Agent is responsible to pad the end of the string with . |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..62) |
|
slSonetSlTable |
1.3.6.1.4.1.4515.1.6.2.2.1 |
The SONET/SDH Signal Label table. This table contains
signal label for the sonet path. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SlSonetSlEntry |
|
slSonetSlEntry |
1.3.6.1.4.1.4515.1.6.2.2.1.1 |
An entry in the SONET/SDH Signal Label table. The entries
exist for active sonet lines. The objects in this table are
used to verify continued connection between the two ends of
the line. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SlSonetSlEntry |
|
|
slSonetSlFailure |
1.3.6.1.4.1.4515.1.6.2.2.1.1.4 |
The value of this object is set to 'true' when Sonet
received signal label does not match the 'slSonetSlToExpect'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
slSonetSlReceived |
1.3.6.1.4.1.4515.1.6.2.2.1.1.5 |
This object is used to view the Sonet Signal Label that is
received by the receiving terminal. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
slSonetPosTable |
1.3.6.1.4.1.4515.1.6.6.1 |
The POS PM Table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SlSonetPosEntry |
|
slSonetPosEntry |
1.3.6.1.4.1.4515.1.6.6.1.1 |
The entries exist for active Trunk sonet lines
ifType = pos(171). The objects in this table are
used to moitor the POS layer. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SlSonetPosEntry |
|
|
slSonetPosFcs |
1.3.6.1.4.1.4515.1.6.6.1.1.1 |
The Number of FCS Errors. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
slSonetPosAbort |
1.3.6.1.4.1.4515.1.6.6.1.1.2 |
The Number of Aborted packets. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
slSonetPosMinViolation |
1.3.6.1.4.1.4515.1.6.6.1.1.3 |
The Number of Minimum length violation packets. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
slSonetPosMaxViolation |
1.3.6.1.4.1.4515.1.6.6.1.1.4 |
The Number of Maximum length violation packets. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
slSonetPosRxfifoDiscard |
1.3.6.1.4.1.4515.1.6.6.1.1.5 |
The Number of packets discarded due to RXFIFO error. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
slSonetAlsEntry |
1.3.6.1.4.1.4515.1.6.7.1.1 |
The entries exist for active sonet lines
ifType = sonet(39). The objects in this table are
used to configure the ALS algorithm. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SlSonetAlsEntry |
|
|
slSonetAlsMode |
1.3.6.1.4.1.4515.1.6.7.1.1.1 |
Enable/Disable the ALS algorithm.
Note that the if the Laser Admin Status is 'down' the
ALS mechanism is not operational. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
slSonetLosDeclareTime |
1.3.6.1.4.1.4515.1.6.7.1.1.2 |
Time to declare optical LOS present or clear: 550 +- 50 msec. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ms500(1), ms550(2), ms600(3) |
|
slSonetTestPulseTime |
1.3.6.1.4.1.4515.1.6.7.1.1.3 |
Manual restart for test Pulse time (in manual restart) - 90+-10 sec. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
s80(1), s90(2), s100(3) |
|
slSonetManualPulseTime |
1.3.6.1.4.1.4515.1.6.7.1.1.4 |
Manual restart Pulse time (in manual mode) - 2+-0.25 sec. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ms1750(1), ms2000(2), ms2250(3) |
|
slSonetAutomaticPulseTime |
1.3.6.1.4.1.4515.1.6.7.1.1.5 |
Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ms1750(1), ms2000(2), ms2250(3) |
|
slSonetAutomaticDelayTime |
1.3.6.1.4.1.4515.1.6.7.1.1.6 |
In Automatic mode. The delay between two laser re-activations. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
60..300 |
|
slSonetLaserTestActivate |
1.3.6.1.4.1.4515.1.6.7.1.1.7 |
Activate the laser for test operation. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
activate(1) |
|
slSonetLaserManualActivate |
1.3.6.1.4.1.4515.1.6.7.1.1.8 |
Activate the laser manual operation. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
activate(1) |
|
slSonetFsTable |
1.3.6.1.4.1.4515.1.6.8.1 |
The frame structure configuration Table.
In order to define a new path the NMS should create and configure
an entry in this table.
The table is also used to monitor the status of the LOP
alarm per path. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SlSonetFsEntry |
|
slSonetFsEntry |
1.3.6.1.4.1.4515.1.6.8.1.1 |
The entries exist for sonet paths
ifType = sonet(39). The objects in this table are
used to configure the frame structure.
Each OC-N line interface shall maintain a static
table with number of lines equal to the N.
Initially the table will be initialized to STS-Nc. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SlSonetFsEntry |
|
|
slSonetFsSts |
1.3.6.1.4.1.4515.1.6.8.1.1.2 |
The number of the first STS in the path.
Note that no all values are legal because there is no
support for combus with mixed structure |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
slSonetFsWidth |
1.3.6.1.4.1.4515.1.6.8.1.1.3 |
The number STS's in the path.
The width is only valid for the first STS in the path.
The other STSs of the path will have width=0. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
slSonetFsFullPathTermination |
1.3.6.1.4.1.4515.1.6.8.1.1.4 |
FALSE - means partial path termination (only LOP alarm).
TRUE - include full support for path Alarms and PM counters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
slSonetFsGranularity |
1.3.6.1.4.1.4515.1.6.8.1.1.5 |
This value is set by the NMS according to the configured frame structure.
Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1).
Otherwise the value should be vc3(2). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
vc4(1), vc3(2) |
|
slSonetFsTableChange |
1.3.6.1.4.1.4515.1.6.11.1 |
A slSonetFsTableChange trap is sent when the
content of the slSonetFsTable is changed.
This trap may be used by the NMS to identify
the removal of path interfaces, or addition of
new path interfaces |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|