SL-SONET-MIB

File: SL-SONET-MIB.mib (28400 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB PerfHist-TC-MIB SL-NE-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Counter64 Gauge32 DisplayString
TruthValue RowStatus MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP InterfaceIndex
ifIndex PerfCurrentCount PerfIntervalCount
PerfTotalCount sitelight

Defined Types

SignalLabel  
STS path signal label -- one byte, C2, class A, is allocated to indicate the construction of the STS SPE. The following hex values of the C2 byte has been defined.
TEXTUAL-CONVENTION    
  INTEGER sigUnequipped(0), sigEquipped(1), sigPathFloatVt(2), sigPathLoackedVt(3), sigPathAsynchDs3(4), sigPathSyntran(5), sigPathAsyncDs4na(18), sigPathAtm(19), sigPathDqdb(20), sigPathFddi(21), sigPathHdlc(22), sigPathGfp(27)  

SlSonetConfigEntry  
SEQUENCE    
  slSonetConfigFrameScramble INTEGER
  slSonetConfigType INTEGER
  slSonetConfigDccSelection INTEGER
  slSonetResetAllCounters INTEGER
  slSonetPortThresholdTrapEnable INTEGER
  slSonetConfigSdThreshold INTEGER
  slSonetConfigSfThreshold INTEGER
  slSonetCompression INTEGER
  slSonetOverheadTunneling INTEGER
  slSonetLopBitmask Counter64
  slSonetTdmTrunk TruthValue
  slSonetFsApply INTEGER
  slSonetTxLte INTEGER
  slSonetReceivedLte INTEGER
  slSonetResetPmThreshold INTEGER
  slSonetResetAlsParams INTEGER
  slSonetTransceiverType INTEGER
  slSonetTransceiverMedia INTEGER

SlSonetTraceEntry  
SEQUENCE    
  slSonetTraceMode INTEGER
  slSonetTraceToTransmit DisplayString
  slSonetTraceToExpect DisplayString
  slSonetTraceFailure TruthValue
  slSonetTraceReceived DisplayString

SlSonetSlEntry  
SEQUENCE    
  slSonetSlToTransmit SignalLabel
  slSonetSlToExpect SignalLabel
  slSonetSlFailure TruthValue
  slSonetSlReceived INTEGER

SlSonetPosEntry  
SEQUENCE    
  slSonetPosFcs Gauge32
  slSonetPosAbort Gauge32
  slSonetPosMinViolation Gauge32
  slSonetPosMaxViolation Gauge32
  slSonetPosRxfifoDiscard Gauge32
  slSonetPosPacketReceived Counter64
  slSonetPosPacketReceivedOk Counter64

SlSonetAlsEntry  
SEQUENCE    
  slSonetAlsMode INTEGER
  slSonetLosDeclareTime INTEGER
  slSonetTestPulseTime INTEGER
  slSonetManualPulseTime INTEGER
  slSonetAutomaticPulseTime INTEGER
  slSonetAutomaticDelayTime INTEGER
  slSonetLaserTestActivate INTEGER
  slSonetLaserManualActivate INTEGER

SlSonetFsEntry  
SEQUENCE    
  slSonetFsIfIndex InterfaceIndex
  slSonetFsSts INTEGER
  slSonetFsWidth INTEGER
  slSonetFsFullPathTermination TruthValue
  slSonetFsGranularity INTEGER

Defined Values

slSonetMib 1.3.6.1.4.1.4515.1.6
This MIB module describes the SiteLight SONET Service. The mib contains the extensions required for the rfc2558.
MODULE-IDENTITY    

slSonetConfig 1.3.6.1.4.1.4515.1.6.1
OBJECT IDENTIFIER    

slSonetOh 1.3.6.1.4.1.4515.1.6.2
OBJECT IDENTIFIER    

slSonetPos 1.3.6.1.4.1.4515.1.6.6
OBJECT IDENTIFIER    

slSonetAls 1.3.6.1.4.1.4515.1.6.7
OBJECT IDENTIFIER    

slSonetFs 1.3.6.1.4.1.4515.1.6.8
OBJECT IDENTIFIER    

slSonetTraps 1.3.6.1.4.1.4515.1.6.11
OBJECT IDENTIFIER    

slSonetOhTrace 1.3.6.1.4.1.4515.1.6.2.1
OBJECT IDENTIFIER    

slSonetOhSl 1.3.6.1.4.1.4515.1.6.2.2
OBJECT IDENTIFIER    

slSonetOhTraps 1.3.6.1.4.1.4515.1.6.2.3
OBJECT IDENTIFIER    

slSonetConfigTable 1.3.6.1.4.1.4515.1.6.1.1
The SONET/SDH configuration table. This table has objects for configuring sonet lines.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlSonetConfigEntry

slSonetConfigEntry 1.3.6.1.4.1.4515.1.6.1.1.1
An entry in the table. There is an entry for each SONET line in the table. Entries are automatically created for an ifType value of sonet(39). 'ifAdminStatus' from the ifTable must be used to enable or disable a line. By default, the line state is down.
Status: current Access: not-accessible
OBJECT-TYPE    
  SlSonetConfigEntry  

slSonetConfigFrameScramble 1.3.6.1.4.1.4515.1.6.1.1.1.1
This object is used to disable or enable the Scrambling option in SONET line. Please refer to GR-253-CORE for frame scrambling.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

slSonetConfigType 1.3.6.1.4.1.4515.1.6.1.1.1.2
This object represents the configured line type for Trunks: sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk) sonetSts192c(12) - 1 x Sts192 (10Gb Trunk) sonetStsOther(13) - for OC-n interfaces see slSonetFsTable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sonetSts3(1), sonetSts3c(2), sonetSts12(3), sonetSts12c(4), sonetSts48c(5), sonetSts3cx4(6), sonetSts48(7), sonetSts3cx16(8), sonetSts3x16(9), sonetSts12cx4(10), sonetSts12x4(11), sonetSts192c(12), sonetStsOther(13)  

slSonetConfigDccSelection 1.3.6.1.4.1.4515.1.6.1.1.1.3
This object selects the DCC type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sonetLineDcc(1), sonetSectionDcc(2), sonetInband(3)  

slSonetResetAllCounters 1.3.6.1.4.1.4515.1.6.1.1.1.4
Setting this variable to 1 will cause all of the counters (performance regsters) on this SONET interface to be initialized to zero (0).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER resetCounters(1)  

slSonetPortThresholdTrapEnable 1.3.6.1.4.1.4515.1.6.1.1.1.5
This variable indicates whether threshold traps should be generated for this SONET interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

slSonetConfigSdThreshold 1.3.6.1.4.1.4515.1.6.1.1.1.6
This object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to -n where n is between 5 and 9 (read-write).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..9  

slSonetConfigSfThreshold 1.3.6.1.4.1.4515.1.6.1.1.1.7
This object contains the Bit Error Rate threshold for Signal Fault detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to the -n, where n is between 3 and 5. (read-write)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 3..5  

slSonetCompression 1.3.6.1.4.1.4515.1.6.1.1.1.9
This object applies only for trunk ports. It specifies if the packets should be compressed. 0 - Means no POS compression, 1 - Means POS compression with CRC-32. 2 - Means POS compression with CRC-16. Note that the two connected trunks should be configured to the same value. Note also that the BW calculation of the OC-n should be changed according to this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER uncompress(0), posCompress32(1), posCompress16(2)  

slSonetOverheadTunneling 1.3.6.1.4.1.4515.1.6.1.1.1.10
The section and line overhead tunneling configuration: none(0) - no tunneling support lineDcc(1) - line DCC tunneling k1k2(2) - line DCC + protection k byte full(3) - all transport overhead bytes are tunneled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), lineDcc(1), k1k2(2), full(3)  

slSonetLopBitmask 1.3.6.1.4.1.4515.1.6.1.1.1.11
The LOP status. Each bit of the bits represent the status of the LOP alarm in corresponding STS. For a path with more than a single STS, only the value of the first STS in the path is relevant. This object is relevant only for the OC-N cards and not for the Trunk. In the next future this object will be replaced with an object of a new table that shall describe the OC-N frame structure.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

slSonetTdmTrunk 1.3.6.1.4.1.4515.1.6.1.1.1.12
This object is applicable only to the OC-n ports. TRUE - means that the OC-n port is used as a TDM Trunk. FLASE - means normal OC-n port.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

slSonetFsApply 1.3.6.1.4.1.4515.1.6.1.1.1.13
Writing to this object activate the slSonetFsTable setting. This allow the NMS to do many changes to the slSonetFsTable and then APPLY them at once. This prevent from going through unconsistent steps. This object always returns the value 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

slSonetTxLte 1.3.6.1.4.1.4515.1.6.1.1.1.14
The SS bits to transmit (bits 5,6 in H1,H1*).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ssb00(1), ssb10(2), auto(5)  

slSonetReceivedLte 1.3.6.1.4.1.4515.1.6.1.1.1.15
The detected LTE type, according to the received SS bits (bits 5,6 in H1,H1*).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ssb00(1), ssb10(2), ssb01(3), ssb11(4), ssbinv(5)  

slSonetResetPmThreshold 1.3.6.1.4.1.4515.1.6.1.1.1.16
Setting this variable to 1 will reset the PM threshold parameters to the factory defaults.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER resetCounters(1)  

slSonetResetAlsParams 1.3.6.1.4.1.4515.1.6.1.1.1.17
Setting this variable to 1 will reset the ALS parameters to the factory defaults.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER resetCounters(1)  

slSonetTransceiverType 1.3.6.1.4.1.4515.1.6.1.1.1.18
The tranceiver type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), shortWave(2), longWave(3)  

slSonetTransceiverMedia 1.3.6.1.4.1.4515.1.6.1.1.1.19
The tranceiver media.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), sm(2), mm(3)  

slSonetTraceTable 1.3.6.1.4.1.4515.1.6.2.1.1
The SONET/SDH Trace table. This table contains objects for tracing the sonet section and path.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlSonetTraceEntry

slSonetTraceEntry 1.3.6.1.4.1.4515.1.6.2.1.1.1
An entry in the trace table. Entries exist for active sonet interfaces. The objects in this table are used to verify continued connection between the two ends of the line.
Status: current Access: not-accessible
OBJECT-TYPE    
  SlSonetTraceEntry  

slSonetTraceMode 1.3.6.1.4.1.4515.1.6.2.1.1.1.1
Determine the Trace Message Mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), monitoring(3)  

slSonetTraceToTransmit 1.3.6.1.4.1.4515.1.6.2.1.1.1.2
Sonet Trace To Transmit. This is string that is transmitted to perform Sonet trace diagnostics. The trace string is repetitively transmited so that a trace receiving terminal can verify its continued connection to the intended transmitter. The default value is a zero-length string. Unless this object is set to a non-zero length string, tracing will not be performed. The Agent is responsible to pad the end of the string with .
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..62)  

slSonetTraceToExpect 1.3.6.1.4.1.4515.1.6.2.1.1.1.3
Sonet Trace Massage To Expect. The receiving terminal verifies if the incoming string matches this string. The value of 'slSonetTraceFailure' indicates whether a trace mismatch occurred. The default value is a zero-length string. The Agent is responsible to pad the end of the string with .
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..62)  

slSonetTraceFailure 1.3.6.1.4.1.4515.1.6.2.1.1.1.4
The value of this object is set to 'true' when Sonet Section received trace does not match the 'slSonetTraceToExpect'.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

slSonetTraceReceived 1.3.6.1.4.1.4515.1.6.2.1.1.1.5
This object is used to view the Sonet Trace Message that is received by the receiving terminal. The Agent is responsible to pad the end of the string with .
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..62)  

slSonetSlTable 1.3.6.1.4.1.4515.1.6.2.2.1
The SONET/SDH Signal Label table. This table contains signal label for the sonet path.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlSonetSlEntry

slSonetSlEntry 1.3.6.1.4.1.4515.1.6.2.2.1.1
An entry in the SONET/SDH Signal Label table. The entries exist for active sonet lines. The objects in this table are used to verify continued connection between the two ends of the line.
Status: current Access: not-accessible
OBJECT-TYPE    
  SlSonetSlEntry  

slSonetSlToTransmit 1.3.6.1.4.1.4515.1.6.2.2.1.1.2
Sonet Signal Label To Transmit.
Status: current Access: read-write
OBJECT-TYPE    
  SignalLabel  

slSonetSlToExpect 1.3.6.1.4.1.4515.1.6.2.2.1.1.3
Sonet Signal Label To Expect.
Status: current Access: read-write
OBJECT-TYPE    
  SignalLabel  

slSonetSlFailure 1.3.6.1.4.1.4515.1.6.2.2.1.1.4
The value of this object is set to 'true' when Sonet received signal label does not match the 'slSonetSlToExpect'.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

slSonetSlReceived 1.3.6.1.4.1.4515.1.6.2.2.1.1.5
This object is used to view the Sonet Signal Label that is received by the receiving terminal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

slSonetPosTable 1.3.6.1.4.1.4515.1.6.6.1
The POS PM Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlSonetPosEntry

slSonetPosEntry 1.3.6.1.4.1.4515.1.6.6.1.1
The entries exist for active Trunk sonet lines ifType = pos(171). The objects in this table are used to moitor the POS layer.
Status: current Access: not-accessible
OBJECT-TYPE    
  SlSonetPosEntry  

slSonetPosFcs 1.3.6.1.4.1.4515.1.6.6.1.1.1
The Number of FCS Errors.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

slSonetPosAbort 1.3.6.1.4.1.4515.1.6.6.1.1.2
The Number of Aborted packets.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

slSonetPosMinViolation 1.3.6.1.4.1.4515.1.6.6.1.1.3
The Number of Minimum length violation packets.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

slSonetPosMaxViolation 1.3.6.1.4.1.4515.1.6.6.1.1.4
The Number of Maximum length violation packets.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

slSonetPosRxfifoDiscard 1.3.6.1.4.1.4515.1.6.6.1.1.5
The Number of packets discarded due to RXFIFO error.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

slSonetPosPacketReceived 1.3.6.1.4.1.4515.1.6.6.1.1.6
The Number of packets received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

slSonetPosPacketReceivedOk 1.3.6.1.4.1.4515.1.6.6.1.1.7
The Number of error free packets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

slSonetAlsTable 1.3.6.1.4.1.4515.1.6.7.1
The ALS configuration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlSonetAlsEntry

slSonetAlsEntry 1.3.6.1.4.1.4515.1.6.7.1.1
The entries exist for active sonet lines ifType = sonet(39). The objects in this table are used to configure the ALS algorithm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SlSonetAlsEntry  

slSonetAlsMode 1.3.6.1.4.1.4515.1.6.7.1.1.1
Enable/Disable the ALS algorithm. Note that the if the Laser Admin Status is 'down' the ALS mechanism is not operational.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

slSonetLosDeclareTime 1.3.6.1.4.1.4515.1.6.7.1.1.2
Time to declare optical LOS present or clear: 550 +- 50 msec.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms500(1), ms550(2), ms600(3)  

slSonetTestPulseTime 1.3.6.1.4.1.4515.1.6.7.1.1.3
Manual restart for test Pulse time (in manual restart) - 90+-10 sec.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER s80(1), s90(2), s100(3)  

slSonetManualPulseTime 1.3.6.1.4.1.4515.1.6.7.1.1.4
Manual restart Pulse time (in manual mode) - 2+-0.25 sec.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms1750(1), ms2000(2), ms2250(3)  

slSonetAutomaticPulseTime 1.3.6.1.4.1.4515.1.6.7.1.1.5
Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms1750(1), ms2000(2), ms2250(3)  

slSonetAutomaticDelayTime 1.3.6.1.4.1.4515.1.6.7.1.1.6
In Automatic mode. The delay between two laser re-activations.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 60..300  

slSonetLaserTestActivate 1.3.6.1.4.1.4515.1.6.7.1.1.7
Activate the laser for test operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activate(1)  

slSonetLaserManualActivate 1.3.6.1.4.1.4515.1.6.7.1.1.8
Activate the laser manual operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER activate(1)  

slSonetFsTable 1.3.6.1.4.1.4515.1.6.8.1
The frame structure configuration Table. In order to define a new path the NMS should create and configure an entry in this table. The table is also used to monitor the status of the LOP alarm per path.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlSonetFsEntry

slSonetFsEntry 1.3.6.1.4.1.4515.1.6.8.1.1
The entries exist for sonet paths ifType = sonet(39). The objects in this table are used to configure the frame structure. Each OC-N line interface shall maintain a static table with number of lines equal to the N. Initially the table will be initialized to STS-Nc.
Status: current Access: not-accessible
OBJECT-TYPE    
  SlSonetFsEntry  

slSonetFsIfIndex 1.3.6.1.4.1.4515.1.6.8.1.1.1
The interface index.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

slSonetFsSts 1.3.6.1.4.1.4515.1.6.8.1.1.2
The number of the first STS in the path. Note that no all values are legal because there is no support for combus with mixed structure
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slSonetFsWidth 1.3.6.1.4.1.4515.1.6.8.1.1.3
The number STS's in the path. The width is only valid for the first STS in the path. The other STSs of the path will have width=0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

slSonetFsFullPathTermination 1.3.6.1.4.1.4515.1.6.8.1.1.4
FALSE - means partial path termination (only LOP alarm). TRUE - include full support for path Alarms and PM counters.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

slSonetFsGranularity 1.3.6.1.4.1.4515.1.6.8.1.1.5
This value is set by the NMS according to the configured frame structure. Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1). Otherwise the value should be vc3(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vc4(1), vc3(2)  

slSonetFsTableChange 1.3.6.1.4.1.4515.1.6.11.1
A slSonetFsTableChange trap is sent when the content of the slSonetFsTable is changed. This trap may be used by the NMS to identify the removal of path interfaces, or addition of new path interfaces
Status: current Access: read-write
NOTIFICATION-TYPE