SLE-MPLS-TP-OAM-MIB

File: SLE-MPLS-TP-OAM-MIB.mib (39907 bytes)

Imported modules

DASAN-SMI IF-MIB MPLS-TC-STD-MIB
SLE-TC-MIB SNMP-FRAMEWORK-MIB SNMPv2-SMI

Imported symbols

sleMgmt ifGeneralInformationGroup ifCounterDiscontinuityGroup
mplsStdMIB SleControlStatusType SleControlRequestResultType
SnmpAdminString zeroDotZero TimeTicks
Unsigned32 Gauge32 OBJECT-TYPE
MODULE-IDENTITY OBJECT-IDENTITY

Defined Types

SleMplsTpOamMegInfoEntry  
SEQUENCE    
  sleMplsTpOamMegInfoIndex Unsigned32
  sleMplsTpOamMegInfoName OCTET STRING
  sleMplsTpOamMegInfoOperatorType INTEGER
  sleMplsTpOamMegInfoServiceType INTEGER
  sleMplsTpOamMegInfoMegLevel INTEGER
  sleMplsTpOamMegInfoOperStatus INTEGER

SleMplsTpOamMaintanceEntityInfoEntry  
SEQUENCE    
  sleMplsTpOamMaintanceEntityInfoMeIndex Unsigned32
  sleMplsTpOamMaintanceEntityInfoMpIndex Unsigned32
  sleMplsOamMaintenanceEntityInfoMeName SnmpAdminString
  sleMplsTpOamMaintanceEntityInfoMpType INTEGER
  sleMplsOamMaintenanceEntityInfoServiceTunnelName OCTET STRING
  sleMplsOamMaintenanceEntityInfoServiceVcId Unsigned32
  sleMplsOamMaintenanceEntityInfoServiceDatalink OCTET STRING
  sleMplsTpOamMaintanceEntityInfoCcInterval Unsigned32
  sleMplsTpOamMaintanceEntityInfoRemoteMpId Unsigned32
  sleMplsTpOamMaintanceEntityInfoRemoteCc OCTET STRING
  sleMplsTpOamMaintanceEntityInfoRemoteIcc OCTET STRING
  sleMplsTpOamMaintanceEntityInfoRemoteMeg OCTET STRING
  sleMplsTpOamMaintanceEntityInfoRemoteMpdirection INTEGER

SleMplsTpOamFmInfoEntry  
SEQUENCE    
  sleMplsTpOamFmInfoMeIndex Unsigned32
  sleMplsTpOamFmInfoMpIndex Unsigned32
  sleMplsTpOamFmInfoFaultManagement INTEGER
  sleMplsTpOamFmInfoRefreshTime Unsigned32
  sleMplsTpOamFmInfoLockInstruct INTEGER
  sleMplsTpOamFmInfoLockInstructRefreshTime Unsigned32
  sleMplsTpOamFmInfoAlarmIndication INTEGER
  sleMplsTpOamFmInfoAlarmIndicationInterval INTEGER
  sleMplsTpOamFmInfoAlarmIndicationLevel INTEGER
  sleMplsTpOamFmInfoLock INTEGER
  sleMplsTpOamFmInfoLockInterval INTEGER
  sleMplsTpOamFmInfoLockLevel INTEGER
  sleMplsTpOamFmInfoLoopBack INTEGER
  sleMplsTpOamFmInfoLoopBackStatus INTEGER
  sleMplsTpOamFmInfoLockInstructStatus INTEGER
  sleMplsTpOamFmInfoFaultManagementStatus INTEGER
  sleMplsTpOamFmInfoCcCvStatus INTEGER
  sleMplsTpOamFmInfoStatus INTEGER

Defined Values

sleMplsTpOam 1.3.6.1.4.1.6296.101.16.17
sleMpls
MODULE-IDENTITY    

sleMpls 1.3.6.1.4.1.6296.101.16
SLE MPLS.
Status: current Access: read-only
OBJECT-IDENTITY    

sleMplsTpOamMeg 1.3.6.1.4.1.6296.101.16.17.1
OBJECT IDENTIFIER    

sleMplsTpOamMegInfoTable 1.3.6.1.4.1.6296.101.16.17.1.1
This table contains information about the Maintenance Entity Groups (MEG). MEG as mentioned in MPLS-TP OAM framework defines a set of one or more maintenance entities (ME). Maintenance Entities define a relationship between any two points of a transport path in an OAM domain to which maintenance and monitoring operations apply.
Status: current Access: read-only
OBJECT-TYPE    
  SEQUENCE OF  
    SleMplsTpOamMegInfoEntry

sleMplsTpOamMegInfoEntry 1.3.6.1.4.1.6296.101.16.17.1.1.1
An entry in this table represents MPLS-TP MEG. An entry can be created by a network administrator or by an SNMP agent as instructed by an MPLS-TP OAM Framework. When a new entry is created with sleMplsTpOamMegOperatorType set to ipCompatible (1), then as per [RFC6370] (MEG_ID for LSP is LSP_ID and MEG_ID for PW is PW_Path_ID), MEP_ID can be automatically formed. For co-routed bidirectional LSP, MEG_ID is A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID:: Node_ID::Tunnel_Num}::LSP_Num. For associated bidirectional LSP, MEG_ID is A1- {Global_ID::Node_ID::Tunnel_Num::LSP_Num}:: Z9- {Global_ID::Node_ID::Tunnel_Num::LSP_Num} For LSP, MEP_ID is formed using, Global_ID::Node_ID::Tunnel_Num::LSP_Num For PW, MEG_ID is formed using AGI::A1- {Global_ID::Node_ID::AC_ID}:: Z9- {Global_ID::Node_ID::AC_ID}. For PW, MEP_ID is formed using AGI::Global_ID::Node_ID::AC_ID MEP_ID is retrieved from the sleMplsTpOamMegServicePointer object based on the sleMplsTpOamMegServiceType value. ICC MEG_ID for LSP and PW is formed using the objects sleMplsTpOamMegIdIcc and sleMplsTpOamMegIdUmc. MEP_ID can be formed using MEG_ID::MEP_Index.
Status: current Access: read-only
OBJECT-TYPE    
  SleMplsTpOamMegInfoEntry  

sleMplsTpOamMegInfoIndex 1.3.6.1.4.1.6296.101.16.17.1.1.1.1
Index for the conceptual row identifying a MEG within this MEG table.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTpOamMegInfoName 1.3.6.1.4.1.6296.101.16.17.1.1.1.2
Each Maintenance Entity Group has unique name amongst all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each MEG. IETF : MEG Name Max. 48 characters long ITUT : MEG Name Max 5 characters(Excluding /).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..48)  

sleMplsTpOamMegInfoOperatorType 1.3.6.1.4.1.6296.101.16.17.1.1.1.3
This object is used to set the IETF or ITUT.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ietf(1), itut(2)  

sleMplsTpOamMegInfoServiceType 1.3.6.1.4.1.6296.101.16.17.1.1.1.4
Indicates the service type for which the MEG is created. If the service type indicates lsp, the service pointer in sleMplsOamMe points to the TE tunnel table entry. If the value is pseudowire service type, the service pointer in sleMplsOamMe points to the pseudowire table entry. If the value is section service type, the service pointer in sleMplsOamMe points to a section entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tunnel(1), vc(2), datalink(3)  

sleMplsTpOamMegInfoMegLevel 1.3.6.1.4.1.6296.101.16.17.1.1.1.5
This variable is used to for level for ITUT. When a row in this table is in active object cannot be changed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

sleMplsTpOamMegInfoOperStatus 1.3.6.1.4.1.6296.101.16.17.1.1.1.6
This object specifies the operational status of the Maintenance Entity Group (MEG). This object is used to send the notification to the SNMP manager about the MEG. The value up (1) indicates that the MEG and its monitored path are operationally up. The value down (2) indicates that the MEG is operationally down. When the value of mplsOamIdMegOperStatus is up(1), all the bits of mplsOamIdMegSubOperStatus must be cleared. When the value of mplsOamIdMegOperStatus is down(2), at least one bit of mplsOamIdMegSubOperStatus must be set.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

sleMplsTpOamMegControl 1.3.6.1.4.1.6296.101.16.17.1.2
OBJECT IDENTIFIER    

sleMplsTpOamMegControlRequest 1.3.6.1.4.1.6296.101.16.17.1.2.1
the configuration commands, and user can configure functions via setting this entry as proper value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER createsleMplsTpOamMegControlEntry(1), deletesleMplsTpOamMegControlEntry(2), setsleMplsTpOamMegControlServiceType(3), setsleMplsTpOamMegControlLevel(4)  

sleMplsTpOamMegControlStatus 1.3.6.1.4.1.6296.101.16.17.1.2.2
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpOamMegControlTimer 1.3.6.1.4.1.6296.101.16.17.1.2.3
the wait-time until setRequest end. In case of short-time command, this value is 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpOamMegControlTimeStamp 1.3.6.1.4.1.6296.101.16.17.1.2.4
the time stamp of the last command. (don.t care)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpOamMegControlReqResult 1.3.6.1.4.1.6296.101.16.17.1.2.5
Result of the last command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpOamMegControlName 1.3.6.1.4.1.6296.101.16.17.1.2.6
Each Maintenance Entity Group has unique name amongst all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each MEG.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..48)  

sleMplsTpOamMegControlOperatorType 1.3.6.1.4.1.6296.101.16.17.1.2.7
Indicates the operator type for MEG. Conceptual rows having 'iccBased' as operator type, should have valid values for the objects sleMplsTpOamMegControlIdIcc and sleMplsTpOamMegControlIdUmc while making the row status active.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ietf(1), itut(2)  

sleMplsTpOamMegControlServiceType 1.3.6.1.4.1.6296.101.16.17.1.2.8
Indicates the service type for which the MEG is created. If the service type indicates lsp, the service pointer in sleMplsOamMe points to the TE tunnel table entry. If the value is pseudowire service type, the service pointer in sleMplsOamMe points to the pseudowire table entry. If the value is section service type, the service pointer in sleMplsOamMe points to a section entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tunnel(1), vc(2), datalink(3)  

sleMplsTpOamMegControlLevel 1.3.6.1.4.1.6296.101.16.17.1.2.9
This variable is used to for level for ITUT. When a row in this table is in active object cannot be changed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

sleMplsTpOamMaintananceEntity 1.3.6.1.4.1.6296.101.16.17.2
OBJECT IDENTIFIER    

sleMplsTpOamMaintanceEntityInfoTable 1.3.6.1.4.1.6296.101.16.17.2.1
This table contains MPLS-TP maintenance entity information. ME is some portion of a transport path that requires management bounded by two points (called MEPs), and the relationship between those points to which maintenance and monitoring operations apply. This table is generic enough to handle MEPs and MIPs information within a MEG.
Status: current Access: read-only
OBJECT-TYPE    
  SEQUENCE OF  
    SleMplsTpOamMaintanceEntityInfoEntry

sleMplsTpOamMaintanceEntityInfoEntry 1.3.6.1.4.1.6296.101.16.17.2.1.1
An entry in this table represents MPLS-TP maintenance entity. This entry represents the ME if the source and sink MEPs are defined. A ME is a p2p entity. One ME has two such MEPs. A MEG is a group of one or more MEs. One MEG can have two or more MEPs. For P2P LSP, one MEG has one ME and this ME is associated two MEPs (source and sink MEPs) within a MEG. Each sleMplsOamMeIndex value denotes the ME within a MEG. In case of unidirectional point-to-point transport paths, a single unidirectional Maintenance Entity is defined to monitor it and sleMplsOamMeServicePointer points to unidirectional point-to-point path. In case of associated bidirectional point-to-point transport paths, two independent unidirectional Maintenance Entities are defined to independently monitor each direction and each sleMplsOamMeServicePointer MIB object points to unique unidirectional transport path. This has implications for transactions that terminate at or query a MIP, as a return path from MIP to source MEP does not necessarily exist within the MEG. In case of co-routed bidirectional point-to-point transport paths, a single bidirectional Maintenance Entity is defined to monitor both directions congruently and sleMplsOamMeServicePointer MIB object points to co-routed bidirectional point-to-point transport path. In case of unidirectional point-to-multipoint transport paths, a single unidirectional Maintenance entity for each leaf is defined to monitor the transport path from the root to that leaf and each leaf has different transport path information in sleMplsOamMeServicePointer MIB object.
Status: current Access: read-only
OBJECT-TYPE    
  SleMplsTpOamMaintanceEntityInfoEntry  

sleMplsTpOamMaintanceEntityInfoMeIndex 1.3.6.1.4.1.6296.101.16.17.2.1.1.1
Uniquely identifies a maintenance entity index within a MEG.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTpOamMaintanceEntityInfoMpIndex 1.3.6.1.4.1.6296.101.16.17.2.1.1.2
Indicates the maintenance point index, used to create multiple MEPs in a node of single ME. The value of this object can be MEP index or MIP index. Managers should obtain new values for row creation in this table by reading mplsOamIdMeMpIndexNext.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..8191  

sleMplsOamMaintenanceEntityInfoMeName 1.3.6.1.4.1.6296.101.16.17.2.1.1.3
This object denotes the ME name, each Maintenance Entity has unique name within MEG.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..48)  

sleMplsTpOamMaintanceEntityInfoMpType 1.3.6.1.4.1.6296.101.16.17.2.1.1.4
Indicates the maintenance point type within the MEG. The object should have the value mep (1), only in the Ingress or Egress nodes of the transport path. The object can have the value mip (2), in the intermediate nodes and possibly in the end nodes of the transport path.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mep(1), mip(2)  

sleMplsOamMaintenanceEntityInfoServiceTunnelName 1.3.6.1.4.1.6296.101.16.17.2.1.1.5
This variable represents a pointer to the MPLS-TP transport path. This value may point at an entry in the sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured as lsp (1) or at an entry in the pwEntry if sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2). Note: This service pointer object, is placed in ME table instead of MEG table, since it will be useful in case of point-to-multipoint, where each ME will point to different branches of a P2MP tree.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleMplsOamMaintenanceEntityInfoServiceVcId 1.3.6.1.4.1.6296.101.16.17.2.1.1.6
This variable represents a pointer to the MPLS-TP transport path. This value may point at an entry in the sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured as lsp (1) or at an entry in the pwEntry if sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2). Note: This service pointer object, is placed in ME table instead of MEG table, since it will be useful in case of point-to-multipoint, where each ME will point to different branches of a P2MP tree.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  


sleMplsTpOamMaintanceEntityInfoCcInterval 1.3.6.1.4.1.6296.101.16.17.2.1.1.8
This variable is used to keep the continuty check interval for ITUT. When a row in this table is in active object cannot be changed.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..7  

sleMplsTpOamMaintanceEntityInfoRemoteMpId 1.3.6.1.4.1.6296.101.16.17.2.1.1.9
This variable is used for setting the remote mep id
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..8191  

sleMplsTpOamMaintanceEntityInfoRemoteCc 1.3.6.1.4.1.6296.101.16.17.2.1.1.10
Global uniqueness is assured by concatenating the ICC with a Country Code (CC). The Country Code (alpha-2) is a string of two alphabetic characters represented with upper case letters (i.e., A-Z). This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

sleMplsTpOamMaintanceEntityInfoRemoteIcc 1.3.6.1.4.1.6296.101.16.17.2.1.1.11
Unique code assigned to Network Operator or Service Provider maintained by ITU-T. The ITU Carrier Code used to form MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..6)  

sleMplsTpOamMaintanceEntityInfoRemoteMeg 1.3.6.1.4.1.6296.101.16.17.2.1.1.12
Unique code assigned by Network Operator or Service Provider and is appended to mplsOamIdMegIdIcc to form the MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..6)  

sleMplsTpOamMaintanceEntityInfoRemoteMpdirection 1.3.6.1.4.1.6296.101.16.17.2.1.1.13
Indicates the maintenance point type within the MEG. This object is used to display the forward and reverse remote mep of Transist router .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(1), reverse(2)  

sleMplsTpOamMaintanceEntityControl 1.3.6.1.4.1.6296.101.16.17.2.2
OBJECT IDENTIFIER    

sleMplsTpOamMaintanceEntityRequest 1.3.6.1.4.1.6296.101.16.17.2.2.1
the configuration commands, and user can configure functions via setting this entry as proper value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER createsleMplsTpOamMaintanceEntityControlEntry(1), deletesleMplsTpOamMaintanceEntityControlEntry(2), setsleMplsTpOamMaintanceEntityControlServiceValue(3), setSleMplsTpOamMepControlCCInterval(4), unsetSleMplsTpOamMepControlCCInterval(5), setsleMplsTpOamMaintanceEntityControlRmepId(6), unsetsleMplsTpOamMaintanceEntityControlRmepId(7)  

sleMplsTpOamMaintanceEntityControlStatus 1.3.6.1.4.1.6296.101.16.17.2.2.2
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpOamMaintanceEntityControlTimer 1.3.6.1.4.1.6296.101.16.17.2.2.3
the wait-time until setRequest end. In case of short-time command, this value is 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpOamMaintanceEntityControlTimeStamp 1.3.6.1.4.1.6296.101.16.17.2.2.4
the time stamp of the last command. (don.t care)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpOamMaintanceEntityControlReqResult 1.3.6.1.4.1.6296.101.16.17.2.2.5
Result of the last command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpOamMaintanceEntityControlMegName 1.3.6.1.4.1.6296.101.16.17.2.2.6
Uniquely identifies a maintenance entity index within a MEG.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpOamMaintanceEntityControlMeName 1.3.6.1.4.1.6296.101.16.17.2.2.7
This object denotes the ME name, each Maintenance Entity has unique name within MEG.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..48)  

sleMplsTpOamMaintanceEntityControlMepId 1.3.6.1.4.1.6296.101.16.17.2.2.8
Uniquely identifies a maintenance entity index within a MEP .
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8191  

sleMplsTpOamMaintanceEntityControlMpType 1.3.6.1.4.1.6296.101.16.17.2.2.9
Indicates the maintenance point type within the MEG. The object should have the value mep (1), only in the Ingress or Egress nodes of the transport path. The object can have the value mip (2), in the intermediate nodes and possibly in the end nodes of the transport path.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mep(1), mip(2)  

sleMplsTpOamMaintanceEntityControlServiceValue 1.3.6.1.4.1.6296.101.16.17.2.2.10
This variable represents a pointer to the MPLS-TP transport path. This value may point at an entry in the sleMplsTunnelEntry if sleMplsOamMeControlgServiceType is configured as lsp (1) or at an entry in the pwEntry if sleMplsOamMeControlgServiceType is configured as pseudowire (2). Note: This service pointer object, is placed in ME table instead of MEG table, since it will be useful in case of point-to-multipoint, where each ME will point to different branches of a P2MP tree.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpOamMaintanceEntityControlCcInterval 1.3.6.1.4.1.6296.101.16.17.2.2.11
This variable is used to keep the continuty check interval for ITUT. When a row in this table is in active object cannot be changed.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..7  

sleMplsTpOamMaintanceEntityControlRemoteMpId 1.3.6.1.4.1.6296.101.16.17.2.2.12
This variable is used for setting the remote mep id
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..8191  

sleMplsTpOamMaintanceEntityControlRemoteCc 1.3.6.1.4.1.6296.101.16.17.2.2.13
Global uniqueness is assured by concatenating the ICC with a Country Code (CC). The Country Code (alpha-2) is a string of two alphabetic characters represented with upper case letters (i.e., A-Z). This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

sleMplsTpOamMaintanceEntityControlRemoteIcc 1.3.6.1.4.1.6296.101.16.17.2.2.14
Unique code assigned to Network Operator or Service Provider maintained by ITU-T. The ITU Carrier Code used to form MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..6)  

sleMplsTpOamMaintanceEntityControlRemoteMeg 1.3.6.1.4.1.6296.101.16.17.2.2.15
Unique code assigned by Network Operator or Service Provider and is appended to mplsOamIdMegIdIcc to form the MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..7)  

sleMplsTpOamMaintanceEntityControlRemoteMpDirection 1.3.6.1.4.1.6296.101.16.17.2.2.16
Indicates the direction of the MEP. This object should be configured if sleMplsOamMeControlMpType is configured as mep (1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fwd(1), rev(2)  

sleMplsTpOamFm 1.3.6.1.4.1.6296.101.16.17.3
OBJECT IDENTIFIER    

sleMplsTpOamFmInfoTable 1.3.6.1.4.1.6296.101.16.17.3.1
Status: current Access: read-only
OBJECT-TYPE    
  SEQUENCE OF  
    SleMplsTpOamFmInfoEntry

sleMplsTpOamFmInfoEntry 1.3.6.1.4.1.6296.101.16.17.3.1.1
An entry in this table represents MPLS-TP maintenance entity.
Status: current Access: read-only
OBJECT-TYPE    
  SleMplsTpOamFmInfoEntry  

sleMplsTpOamFmInfoMeIndex 1.3.6.1.4.1.6296.101.16.17.3.1.1.1
Uniquely identifies a maintenance entity index within a MEG.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTpOamFmInfoMpIndex 1.3.6.1.4.1.6296.101.16.17.3.1.1.2
Indicates the maintenance point index, used to create multiple MEPs in a node of single ME. The value of this object can be MEP index or MIP index. Managers should obtain new values for row creation in this table by reading mplsOamIdMeMpIndexNext.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..8191  

sleMplsTpOamFmInfoFaultManagement 1.3.6.1.4.1.6296.101.16.17.3.1.1.3
Fault Managment for IETF shows enable or disable
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleMplsTpOamFmInfoRefreshTime 1.3.6.1.4.1.6296.101.16.17.3.1.1.4
This Object is used in IETF-based Fault Management RefreshTimer.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..20  

sleMplsTpOamFmInfoLockInstruct 1.3.6.1.4.1.6296.101.16.17.3.1.1.5
Lock instruct for IETF shows enable or disable
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleMplsTpOamFmInfoLockInstructRefreshTime 1.3.6.1.4.1.6296.101.16.17.3.1.1.6
This Object is used in IETF-based lock RefreshTimer.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..20  

sleMplsTpOamFmInfoAlarmIndication 1.3.6.1.4.1.6296.101.16.17.3.1.1.7
Alarm indication for ITUT shows enable or disable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleMplsTpOamFmInfoAlarmIndicationInterval 1.3.6.1.4.1.6296.101.16.17.3.1.1.8
This is object to display the itut alarm indication interval value.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oneSecond(1), sixtySeconds(2)  

sleMplsTpOamFmInfoAlarmIndicationLevel 1.3.6.1.4.1.6296.101.16.17.3.1.1.9
This object to display the Itut alarm indication Level value.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

sleMplsTpOamFmInfoLock 1.3.6.1.4.1.6296.101.16.17.3.1.1.10
This Object is used in ITUT-based lock. This object will enable/disable the lock
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleMplsTpOamFmInfoLockInterval 1.3.6.1.4.1.6296.101.16.17.3.1.1.11
This object is used to display the ITUT based Lock Interval.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oneSecond(1), sixtySeconds(2)  

sleMplsTpOamFmInfoLockLevel 1.3.6.1.4.1.6296.101.16.17.3.1.1.12
This object is used to Display the ITUT based Lock Level.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

sleMplsTpOamFmInfoLoopBack 1.3.6.1.4.1.6296.101.16.17.3.1.1.13
This Object is used in IETF-based loop back. This will show enable/disable loop back .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleMplsTpOamFmInfoLoopBackStatus 1.3.6.1.4.1.6296.101.16.17.3.1.1.14
This object to display the Status of IETF Based LoopBackStatus.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

sleMplsTpOamFmInfoLockInstructStatus 1.3.6.1.4.1.6296.101.16.17.3.1.1.15
This object to display the Status of IETF Based LockInstruct.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

sleMplsTpOamFmInfoFaultManagementStatus 1.3.6.1.4.1.6296.101.16.17.3.1.1.16
This object to display the Status of IETF Based FaultManagement.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

sleMplsTpOamFmInfoCcCvStatus 1.3.6.1.4.1.6296.101.16.17.3.1.1.17
This object to display the Status of IETF Based CC-CV.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

sleMplsTpOamFmInfoStatus 1.3.6.1.4.1.6296.101.16.17.3.1.1.18
This object is used to display the IETF Status 1- path not Associated. 2- path associated with another me. 3- path down 4- received AIS Message. 5- received LKR FM Message. 6- Bfd Detected Loc. 7- Server Layer Down. 8- Invalid Me.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pathNotAssociated(1), pathAssociateWithAnotherMe(2), pathDown(3), receivedAisFmMessage(4), receviedLkrFmMessage(5), bfdDetecLoc(6), serverLayerDown(7), invalidMe(8)  

sleMplsTpOamFmControlTable 1.3.6.1.4.1.6296.101.16.17.3.2
OBJECT IDENTIFIER    

sleMplsTpOamFmControlRequest 1.3.6.1.4.1.6296.101.16.17.3.2.1
the configuration commands, and user can configure functions via setting this entry as proper value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSleMplsTpOamFmControlInit(1), unsetSleMplsTpOamFmControlInit(2), setSleMplsTpOamItutAis(3), unsetSleMplsTpOamItutAis(4), setSleMplsTpOamItutLockInterval(5), unsetSleMplsTpOamItutLockInterval(6)  

sleMplsTpOamFmControlStatus 1.3.6.1.4.1.6296.101.16.17.3.2.2
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpOamFmControlTimer 1.3.6.1.4.1.6296.101.16.17.3.2.3
the wait-time until setRequest end. In case of short-time command, this value is 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpOamFmControlTimeStamp 1.3.6.1.4.1.6296.101.16.17.3.2.4
the time stamp of the last command. (don.t care)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpOamFmControlReqResult 1.3.6.1.4.1.6296.101.16.17.3.2.5
Result of the last command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpOamFmControlMegName 1.3.6.1.4.1.6296.101.16.17.3.2.6
Uniquely identifies a maintenance entity index within a MEG.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpOamFmControlMeName 1.3.6.1.4.1.6296.101.16.17.3.2.7
Uniquely identifies a maintenance entity index within a ME.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpOamFmControlMepId 1.3.6.1.4.1.6296.101.16.17.3.2.8
Uniquely identifies a maintenance entity index within a MEP.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8191  

sleMplsTpOamFmInit 1.3.6.1.4.1.6296.101.16.17.3.2.9
This variable is used for setting the fault Measurments for IETF/ITUT based upon gloable configuration 1) Fault measurment is for IETF 2) Lock-Instruct is for IETF 3) LoopBack to configure for IETF
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER faultMeasurment(1), lockInstruct(2), loopBack(3)  

sleMplsTpOamFmControlRefreshTime 1.3.6.1.4.1.6296.101.16.17.3.2.10
This varible is used to set the Refresh Time for IETF of 2 objects ie., Fault managment and Lock Instruct 1) Fault managment range (1-20) 2) Lock-Instruct range (1-255)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..255  

sleMplsTpOamFmControlInterval 1.3.6.1.4.1.6296.101.16.17.3.2.11
This variable is used to set the interval for 2 alarm-inidaction and lock objects of ITUT
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oneOne(1), sixtyOne(2)  

sleMplsTpOamFmControlLevel 1.3.6.1.4.1.6296.101.16.17.3.2.12
This varible is used to set the level for Alarm indication and lock objects of ITUT
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..7