SMARTD-MIB

File: SMARTD-MIB.mib (34300 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
GEN-MIB

Imported symbols

Counter TimeTicks OBJECT-TYPE
DisplayString ifIndex lannet

Defined Types

Timeout  
INTEGER    

MacAddress  
OCTET STRING Size(6)    

SmartIfExtensionEntry  
SEQUENCE    
  smartIfExtensionEthStatus INTEGER
  smartIfExtensionActivity INTEGER
  smartIfExtensionViNet INTEGER
  smartIfExtensionPriorityLevel INTEGER
  smartIfExtensionBridgeEnable INTEGER
  smartIfExtensionBackPressure INTEGER
  smartIfExtensionSTAEnable INTEGER

SmartViNetEntry  
SEQUENCE    
  smartViNetNumberPlusOne INTEGER
  smartViNetNumOfMembers INTEGER

SmartViNetElanEntry  
SEQUENCE    
  smartViNetElanAssociation INTEGER
  smartViNetElanViNet INTEGER
  smartViNetElanName DisplayString
  smartViNetElanEntryStatus INTEGER
  smartViNetElanIfIndex INTEGER

SmartViNetFdbEntry  
SEQUENCE    
  smartViNetFdbPlusOne INTEGER
  smartViNetFdbAddress MacAddress
  smartViNetFdbPort INTEGER
  smartViNetFdbStatus INTEGER

SmartViNetStpEntry  
SEQUENCE    
  smartViNetStpPlusOne INTEGER
  smartViNetStpPriority INTEGER
  smartViNetStpTimeSinceTopologyChange TimeTicks
  smartViNetStpTopChanges Counter
  smartViNetStpDesignatedRoot OCTET STRING
  smartViNetStpRootCost INTEGER
  smartViNetStpRootPort INTEGER
  smartViNetStpMaxAge Timeout
  smartViNetStpHelloTime Timeout
  smartViNetStpHoldTime INTEGER
  smartViNetStpForwardDelay Timeout
  smartViNetStpBridgeMaxAge Timeout
  smartViNetStpBridgeHelloTime Timeout
  smartViNetStpBridgeForwardDelay Timeout
  smartViNetStpLastChange TimeTicks

SmartLSFEntry  
SEQUENCE    
  smartLSFMACAddr OCTET STRING
  smartLSFEntryStatus INTEGER

Defined Values

smartDevices 1.3.6.1.4.1.81.27
OBJECT IDENTIFIER    

smartGeneral 1.3.6.1.4.1.81.27.1
OBJECT IDENTIFIER    

smartGenSWVersion 1.3.6.1.4.1.81.27.1.1
ASCII string for description and display of the smart device software version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

smartGenOSVersion 1.3.6.1.4.1.81.27.1.2
ASCII string for description and display of the smart device operating system (kernel) version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

smartGenSoftwareDscr 1.3.6.1.4.1.81.27.1.3
ASCII string for description and display of the smart device software information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

smartGenBootVersion 1.3.6.1.4.1.81.27.1.4
ASCII string for description and display of the smart device boot software version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

smartGenReset 1.3.6.1.4.1.81.27.1.5
Setting the value of this attribute to ON is interpreted as a reset command for the whole device. It initiates a complete re-initialization of the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

smartGenHardwareVersion 1.3.6.1.4.1.81.27.1.6
ASCII string for description and display of the agent hardware version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

smartGenMonitoringPort 1.3.6.1.4.1.81.27.1.7
Enables a user to fix one port to monitor other segment ports. For the moment, the monitoring port is port 16. In this case, this port doesn't participate to any other functions of the device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartGenMonitoredPort 1.3.6.1.4.1.81.27.1.8
Value '0' is illegal when Monitor Mode is on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

smartGenLastChange 1.3.6.1.4.1.81.27.1.9
This attribute contains the value of sysUpTime at the time any change pertaining to the device: The changes are regarding the parameters of this group and any parameters of smartIfExtensionTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

smartGenMonitorMode 1.3.6.1.4.1.81.27.1.10
Activates the monitor function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

smartGenNetworkPrefix 1.3.6.1.4.1.81.27.1.11
For ATM devices, the prefix of the switch connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(13)  

smartGenConnectMode 1.3.6.1.4.1.81.27.1.12
Enables the user to configure the ATM interface of the smart device to work in front another ATM port of a smart device: pvc or in front a switch with lane10.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lane10(1), pvc(2), notSupported(255)  

smartGenPvcVP 1.3.6.1.4.1.81.27.1.13
When the smart device is in mode pvc, the VP on which the data is runing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartGenPvcVC 1.3.6.1.4.1.81.27.1.14
When the smart device is in mode pvc, the VC on which the data is runing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartGenSlotNumber 1.3.6.1.4.1.81.27.1.15
Identifies the location (slot number) of the device in the chassis. The first slot is 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartGenHubMgmtIfType 1.3.6.1.4.1.81.27.1.16
This attribute describes one of the interfaces of agents existing on modules and their type. Value 'none' defines the lack of an interface whose type is recognized by the management console. Any other value defines an interface whose type is recognized by the management console and may be used as a management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), regular1822(2), hdh1822(3), ddn-x25(4), rfc877-x25(5), ethernet-csmacd(6), iso88023-csmacd(7), iso88024-tokenBus(8), iso88025-tokenRing(9), iso88026-man(10), starLan(11), proteon-10MBit(12), proteon-80MBit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), t1-carrier(18), cept(19), basicIsdn(20), primaryIsdn(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet-3Mbit(26), nsip(27), slip(28), ultra(29), ds3(30), sip(31), frameRelay(32), rs232(33), para(34), arcnet(35), arcnetPlus(36), atm(37), miox25(38), sonet(39), x25ple(40), iso88022llc(41), localTalk(42), smdsDxi(43), frameRelayService(44), v35(45), hssi(46), hippi(47), modem(48), aal5(49), sonetPath(50), sonetVT(51), smdsIcip(52), propVirtual(53), propMultiplexor(54), ip(255)  

smartGenHubAddr 1.3.6.1.4.1.81.27.1.17
This attribute defines an unique address by which the agent may be addressed by the management console. The address format should be consistent with the type defined by chAgHubMgmtIfType.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

smartAgent 1.3.6.1.4.1.81.27.2
OBJECT IDENTIFIER    

smartAgCoprocCommStatus 1.3.6.1.4.1.81.27.2.1
Attribute describing the status of the communication between the agent and its coprocessor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), commProblems(2), timeout(3)  

smartAgCommDebugMode 1.3.6.1.4.1.81.27.2.2
Attribute describing the agent mode in which communication problem traps are sent to managers (value 'on') or are not sent to managers (value 'off').
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

smartAgConfigChangeTraps 1.3.6.1.4.1.81.27.2.3
The value of this attributes determines whether or not the agent sends Configuration Change traps to the manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

smartAgFaultTraps 1.3.6.1.4.1.81.27.2.4
The value of this attributes determines whether or not the agent sends Fault traps to the manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

smartAgLaneFaultTraps 1.3.6.1.4.1.81.27.2.5
The value of this attributes determines whether or not the agent sends Fault traps when it cannot connect to some ELAN to the manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

smartAgSoftwareStatus 1.3.6.1.4.1.81.27.2.6
Describes configuration of the firmware on this agent. unLoadable(1) - is returned by agents which do not support the Software Download feature; loaded(2) - is returned by agents with loaded software; downLoading(3) - when the attribute is set to this value by manager, it triggers the Software Download procedure. When procedure finished, agent software will reestablish value 'loaded(2)'. downLoadOfDownload (4) - when the attribute is set to this value by manager, it causes the Agent to download the new download software. When procedure finished, agent software will reestablish value 'loaded(2)'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unLoadable(1), loaded(2), downLoading(3), downLoadOfDownload(4)  

smartIfExtension 1.3.6.1.4.1.81.27.3
OBJECT IDENTIFIER    

smartIfExtensionTable 1.3.6.1.4.1.81.27.3.1
This table contains additional information concerning physical interfaces. (Ethernet and ATM ports.)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmartIfExtensionEntry

smartIfExtensionEntry 1.3.6.1.4.1.81.27.3.1.1
Additional information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SmartIfExtensionEntry  

smartIfExtensionEthStatus 1.3.6.1.4.1.81.27.3.1.1.1
Valid for Ethernet Type only
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), rld(2), tld(4), notSupported(255)  

smartIfExtensionActivity 1.3.6.1.4.1.81.27.3.1.1.2
Valid for ATM Type supporting redundancy.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notActive(1), standby(2), active(3), notSupported(255)  

smartIfExtensionViNet 1.3.6.1.4.1.81.27.3.1.1.3
Virtual Net Number. Value '0' for generic mode. The value for not supported is 511.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

smartIfExtensionPriorityLevel 1.3.6.1.4.1.81.27.3.1.1.4
This attribute defines the priority levels of Ethernet ports. The highest priority is video.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER video(3), default(5), notSupported(255)  

smartIfExtensionBridgeEnable 1.3.6.1.4.1.81.27.3.1.1.5
Valid for Ethernet port when in sniffer mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notSupported(255)  

smartIfExtensionBackPressure 1.3.6.1.4.1.81.27.3.1.1.6
Enables a user to disable the backpressure mechanism.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notSupported(255)  

smartIfExtensionSTAEnable 1.3.6.1.4.1.81.27.3.1.1.7
Allows user to take out a port from the STA.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notSupported(255)  

smartViNet 1.3.6.1.4.1.81.27.4
OBJECT IDENTIFIER    

smartViNetMaxNumOfNets 1.3.6.1.4.1.81.27.4.1
Maximum number of local ViNets supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetCurrentBridge 1.3.6.1.4.1.81.27.4.2
ViNet that is the current owner of the STA group, and forwarding table in the bridge MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

smartViNetTable 1.3.6.1.4.1.81.27.4.3
This table contains the number of members belonging to each virtual nets .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmartViNetEntry

smartViNetEntry 1.3.6.1.4.1.81.27.4.3.1
Each Virtual Net will be an isolated entity. The first row of this table is the generic virtual net and is read-only.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SmartViNetEntry  

smartViNetNumberPlusOne 1.3.6.1.4.1.81.27.4.3.1.1
Correspondance for Virtual Net: ViNet: zero is 'generic'
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

smartViNetNumOfMembers 1.3.6.1.4.1.81.27.4.3.1.2
Number of members.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetElanTable 1.3.6.1.4.1.81.27.4.4
This table contains all the information concerning the association between virtual nets and ELAN name.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmartViNetElanEntry

smartViNetElanEntry 1.3.6.1.4.1.81.27.4.4.1
Each Virtual Net will be associated to an ELAN. The vinet = 0 is the first entry of the device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SmartViNetElanEntry  

smartViNetElanAssociation 1.3.6.1.4.1.81.27.4.4.1.1
The association number. For the first association, this entry is read-only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

smartViNetElanViNet 1.3.6.1.4.1.81.27.4.4.1.2
The virtual net number. For the first row, this entry is read-only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

smartViNetElanName 1.3.6.1.4.1.81.27.4.4.1.3
The ELAN name. For the first row, this entry is 'default' and is read-only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

smartViNetElanEntryStatus 1.3.6.1.4.1.81.27.4.4.1.4
The status of the entry. When the console starts to set the parameters of the row, the agent sets the status to notReady. The status createAndWait is set by the console, when the row is complete. After reset of the device, the row is 'active(1)'. When the console has to delete a row, it sets the status to 'destroy'. After reset, the row should disappear.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndWait(4), destroy(5)  

smartViNetElanIfIndex 1.3.6.1.4.1.81.27.4.4.1.5
Creating a row in this table causes the agent to add one row in the interface table. Before setting the row status to active, the agent fill this field with the value of the ifIndex of the new created row.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetFdbTable 1.3.6.1.4.1.81.27.4.5
This table is the forwarding table per virtual net.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmartViNetFdbEntry

smartViNetFdbEntry 1.3.6.1.4.1.81.27.4.5.1
The forwarding tables. The smartViNetFdbPlusOne = 1 corresponds to ViNet generic.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SmartViNetFdbEntry  

smartViNetFdbPlusOne 1.3.6.1.4.1.81.27.4.5.1.1
This table is indexed by the virtual net number plus 1, since the first group is '0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetFdbAddress 1.3.6.1.4.1.81.27.4.5.1.2
A unicast MAC address for which the bridge has forwarding and/or filtering information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

smartViNetFdbPort 1.3.6.1.4.1.81.27.4.5.1.3
Either the value '0', or the port number of the port on which a frame having a source address equal to the value of the corresponding instance of dot1dTpFdbAddress has been seen. A value of '0' indicates that the port number has not been learned but that the bridge does have some forwarding/filtering information about this address (e.g. in the dot1dStaticTable). Implementors are encouraged to assign the port value to this object whenever it is learned even for addresses for which the corresponding value of dot1dTpFdbStatus is not learned(3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetFdbStatus 1.3.6.1.4.1.81.27.4.5.1.4
see dot1dTpFdbStatus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), invalid(2), learned(3), self(4), mgmt(5)  

smartViNetStpTable 1.3.6.1.4.1.81.27.4.6
This table contains all the information concerning the STA parameters per group.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmartViNetStpEntry

smartViNetStpEntry 1.3.6.1.4.1.81.27.4.6.1
The bridge will function between each of those entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SmartViNetStpEntry  

smartViNetStpPlusOne 1.3.6.1.4.1.81.27.4.6.1.1
This table is indexed by the virtual net number plus 1, since the first group is '0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetStpPriority 1.3.6.1.4.1.81.27.4.6.1.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

smartViNetStpTimeSinceTopologyChange 1.3.6.1.4.1.81.27.4.6.1.3
The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

smartViNetStpTopChanges 1.3.6.1.4.1.81.27.4.6.1.4
The total number of topology changes detected by this bridge since the management entity was last reset or initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

smartViNetStpDesignatedRoot 1.3.6.1.4.1.81.27.4.6.1.5
The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

smartViNetStpRootCost 1.3.6.1.4.1.81.27.4.6.1.6
The cost of the path to the root as seen from this bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetStpRootPort 1.3.6.1.4.1.81.27.4.6.1.7
The port number of the port which offers the lowest cost path from this bridge to the root bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetStpMaxAge 1.3.6.1.4.1.81.27.4.6.1.8
The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Timeout  

smartViNetStpHelloTime 1.3.6.1.4.1.81.27.4.6.1.9
The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Timeout  

smartViNetStpHoldTime 1.3.6.1.4.1.81.27.4.6.1.10
This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

smartViNetStpForwardDelay 1.3.6.1.4.1.81.27.4.6.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Timeout  

smartViNetStpBridgeMaxAge 1.3.6.1.4.1.81.27.4.6.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  Timeout 600..4000  

smartViNetStpBridgeHelloTime 1.3.6.1.4.1.81.27.4.6.1.13
The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1d/D9 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Timeout 100..1000  

smartViNetStpBridgeForwardDelay 1.3.6.1.4.1.81.27.4.6.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  Timeout 400..3000  

smartViNetStpLastChange 1.3.6.1.4.1.81.27.4.6.1.15
This attribute contains the value of sysUpTime at the time any change pertaining to the specified STA occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

smartViNetConsoleManagement 1.3.6.1.4.1.81.27.4.7
The ViNet to which the console belongs to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

smartFatherHub 1.3.6.1.4.1.81.27.5
OBJECT IDENTIFIER    

smartFatherNumberOfMac 1.3.6.1.4.1.81.27.5.1
Number of MAC Addresses of the box agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..6  

smartFatherMacList 1.3.6.1.4.1.81.27.5.2
This variable is the list of Mac Addresses of the box agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..36)  

smartLSFddi 1.3.6.1.4.1.81.27.6
OBJECT IDENTIFIER    

smartLSFTable 1.3.6.1.4.1.81.27.6.1
This table contains the MAC addresses of all LSF100 modules on the FDDI ring. This information is needed for LANNET Topology application.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmartLSFEntry

smartLSFEntry 1.3.6.1.4.1.81.27.6.1.1
A table entry containing MAC addresses of all LSF100 modules on the FDDI ring.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SmartLSFEntry  

smartLSFMACAddr 1.3.6.1.4.1.81.27.6.1.1.1
This item defines the MAC address of an LSF100 connected to the FDDI ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

smartLSFEntryStatus 1.3.6.1.4.1.81.27.6.1.1.2
Only the status active(1) is relevant to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndWait(4), destroy(5)  

macInFrames 1.3.6.1.4.1.81.27.6.2
A count of the number of frames received by this MAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

macCopiedFrames 1.3.6.1.4.1.81.27.6.3
A count of the number of frames addressed to and successfully copied into the station's receive buffers by this MAC. This count does not include MAC frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

macOutFrames 1.3.6.1.4.1.81.27.6.4
A count of the number of frames trasmitted by this MAC. This count does not include MAC frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

macTokenRcvd 1.3.6.1.4.1.81.27.6.5
A count of the number of times the station has received a token on this MAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

macErrFrames 1.3.6.1.4.1.81.27.6.6
A count of the number of frames that were detected in error by this MAC that had not been detected in error by another MAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

macLostFrames 1.3.6.1.4.1.81.27.6.7
A count of the number of instances that this MAC detected a format error during frame reception, such that the frame was stripped.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

macNotCopiedFrames 1.3.6.1.4.1.81.27.6.8
A count of the number of frames addressed to this MAC but were not copied into the station's receive buffers. This count does not include MAC frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

macRingOpState 1.3.6.1.4.1.81.27.6.9
A count of the number of times the ring has entered the Ring Operational state from the Ring Not Operational state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fddiRingUtilization 1.3.6.1.4.1.81.27.6.10
A utilization of the FDDI ring, attached to the LSF100 modules (or other members in the family).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER