SNA-LLC-MIB

File: SNA-LLC-MIB.mib (84134 bytes)

Imported modules

SNMPv2-SMI RFC-1212 RFC-1215
SNMPv2-TC-v1 RFC1213-MIB

Imported symbols

experimental Counter32 Integer32
TimeTicks OBJECT-TYPE TRAP-TYPE
DisplayString RowStatus ifIndex

Defined Types

LlcPortAdminEntry  
SEQUENCE    
  llcPortAdminName DisplayString
  llcPortAdminState INTEGER
  llcPortAdminMaxIPDUOctetsSend Integer32
  llcPortAdminMaxIPDUOctetsRcv Integer32
  llcPortAdminMaxUnackedIPDUsSend INTEGER
  llcPortAdminMaxUnackedIPDUsRcv INTEGER
  llcPortAdminMaxRetransmits INTEGER
  llcPortAdminAckTimer TimeTicks
  llcPortAdminPbitTimer TimeTicks
  llcPortAdminRejTimer TimeTicks
  llcPortAdminBusyTimer TimeTicks
  llcPortAdminInactTimer TimeTicks
  llcPortAdminDelayAckCount INTEGER
  llcPortAdminDelayAckTimer TimeTicks
  llcPortAdminSimRim INTEGER

LlcPortOperEntry  
SEQUENCE    
  llcPortOperName DisplayString
  llcPortOperISTATUS INTEGER
  llcPortOperLastModifyTime TimeTicks
  llcPortOperLastFailTime TimeTicks
  llcPortOperLastFailCause INTEGER

LlcPortStatsEntry  
SEQUENCE    
  llcPortStatsPhysicalFailures Counter32
  llcPortStatsPollsIn Counter32
  llcPortStatsPollsOut Counter32
  llcPortStatsPollRspsIn Counter32
  llcPortStatsPollRspsOut Counter32
  llcPortStatsLocalBusies Counter32
  llcPortStatsRemoteBusies Counter32
  llcPortStatsIFramesIn Counter32
  llcPortStatsIFramesOut Counter32
  llcPortStatsOctetsIn Counter32
  llcPortStatsOctetsOut Counter32
  llcPortStatsProtocolErrs Counter32
  llcPortStatsActivityTOs Counter32
  llcPortStatsRetriesExps Counter32
  llcPortStatsRetransmitsIn Counter32
  llcPortStatsRetransmitsOut Counter32

LlcSapAdminEntry  
SEQUENCE    
  llcSapNumber INTEGER
  llcSapAdminState INTEGER
  llcSapAdminMaxIPDUOctetsSend Integer32
  llcSapAdminMaxIPDUOctetsRcv Integer32
  llcSapAdminMaxUnackedIPDUsSend INTEGER
  llcSapAdminMaxUnackedIPDUsRcv INTEGER
  llcSapAdminMaxRetransmits INTEGER
  llcSapAdminAckTimer TimeTicks
  llcSapAdminPbitTimer TimeTicks
  llcSapAdminRejTimer TimeTicks
  llcSapAdminBusyTimer TimeTicks
  llcSapAdminInactTimer TimeTicks
  llcSapAdminDelayAckCount INTEGER
  llcSapAdminDelayAckTimer TimeTicks

LlcSapOperEntry  
SEQUENCE    
  llcSapOperStatus INTEGER

LlcSapStatsEntry  
SEQUENCE    
  llcSapStatsTESTsIn Counter32
  llcSapStatsTESTsOut Counter32
  llcSapStatsXIDsIn Counter32
  llcSapStatsXIDsOut Counter32
  llcSapStatsUIFramesIn Counter32
  llcSapStatsUIFramesOut Counter32

LlcCcAdminEntry  
SEQUENCE    
  llcCcLSap INTEGER
  llcCcRSap INTEGER
  llcCcLMac OCTET STRING
  llcCcRMac OCTET STRING
  llcCcAdminState INTEGER
  llcCcAdminMaxIPDUOctetsSend Integer32
  llcCcAdminMaxIPDUOctetsRcv Integer32
  llcCcAdminMaxUnackedIPDUsSend INTEGER
  llcCcAdminMaxUnackedIPDUsRcv INTEGER
  llcCcAdminMaxRetransmits INTEGER
  llcCcAdminAckTimer TimeTicks
  llcCcAdminPbitTimer TimeTicks
  llcCcAdminRejTimer TimeTicks
  llcCcAdminBusyTimer TimeTicks
  llcCcAdminInactTimer TimeTicks
  llcCcAdminDelayAckCount INTEGER
  llcCcAdminDelayAckTimer TimeTicks
  llcCcAdminRowStatus RowStatus

LlcCcOperEntry  
SEQUENCE    
  llcCcOperRole INTEGER
  llcCcOperState INTEGER
  llcCcOperMaxIPDUOctetsSend Integer32
  llcCcOperMaxIPDUOctetsRcv Integer32
  llcCcOperMaxUnackedIPDUsSend INTEGER
  llcCcOperMaxUnackedIPDUsRcv INTEGER
  llcCcOperMaxRetransmits INTEGER
  llcCcOperAckTimer TimeTicks
  llcCcOperPbitTimer TimeTicks
  llcCcOperRejTimer TimeTicks
  llcCcOperBusyTimer TimeTicks
  llcCcOperInactTimer TimeTicks
  llcCcOperDelayAckCount INTEGER
  llcCcOperDelayAckTimer TimeTicks
  llcCcOperCreateTime TimeTicks
  llcCcOperLastModifyTime TimeTicks
  llcCcOperLastFailTime TimeTicks
  llcCcOperLastFailCause INTEGER
  llcCcOperLastFailFRMRInfo OCTET STRING

LlcCcStatsEntry  
SEQUENCE    
  llcCcStatsLocalBusies Counter32
  llcCcStatsRemoteBusies Counter32
  llcCcStatsIFramesIn Counter32
  llcCcStatsIFramesOut Counter32
  llcCcStatsIOctetsIn Counter32
  llcCcStatsIOctetsOut Counter32
  llcCcStatsREJsIn Counter32
  llcCcStatsREJsOut Counter32
  llcCcStatsRetransmitsIn Counter32
  llcCcStatsRetransmitsOut Counter32
  llcCcStatsFRMRsIn Counter32
  llcCcStatsFRMRsOut Counter32
  llcCcStatsDISCsIn Counter32
  llcCcStatsDISCsOut Counter32
  llcCcStatsUAsIn Counter32
  llcCcStatsUAsOut Counter32
  llcCcStatsDMsIn Counter32
  llcCcStatsDMsOut Counter32
  llcCcStatsSABMEsIn Counter32
  llcCcStatsSABMEsOut Counter32
  llcCcStatsProtocolErrs Counter32
  llcCcStatsActivityTOs Counter32
  llcCcStatsRetriesExps Counter32

Defined Values

snaDLCexp 1.3.6.1.3.51
OBJECT IDENTIFIER    

llc 1.3.6.1.3.51.1
OBJECT IDENTIFIER    

llcPortGroup 1.3.6.1.3.51.1.1
OBJECT IDENTIFIER    

llcSapGroup 1.3.6.1.3.51.1.2
OBJECT IDENTIFIER    

llcCcGroup 1.3.6.1.3.51.1.3
OBJECT IDENTIFIER    

llcTraps 1.3.6.1.3.51.1.4
OBJECT IDENTIFIER    

llcConformance 1.3.6.1.3.51.1.5
OBJECT IDENTIFIER    

llcCompliances 1.3.6.1.3.51.1.5.1
OBJECT IDENTIFIER    

llcGroups 1.3.6.1.3.51.1.5.2
OBJECT IDENTIFIER    

llcCoreGroups 1.3.6.1.3.51.1.5.2.1
OBJECT IDENTIFIER    

llcPortAdminTable 1.3.6.1.3.51.1.1.1
This table contains objects that can be changed to manage an LLC port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the llcPortOperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was changed after the interface was started.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortAdminEntry

llcPortAdminEntry 1.3.6.1.3.51.1.1.1.1
A list of configured values for an LLC port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcPortAdminEntry  

llcPortAdminName 1.3.6.1.3.51.1.1.1.1.1
An octet string that defines the physical port to which this interface is assigned. It has implementation-specific significance. Its value shall be unique within the administered system. It must contain only ASCII printable characters. Should an implementation choose to accept a write operation for this object, it causes the logical port definition associated with the table instance to be moved to a different physical port. A write operation shall not take effect until the port is cycled inactive.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..10)  

llcPortAdminState 1.3.6.1.3.51.1.1.1.1.2
This parameter controls the desired state of the LLC protocol for this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

llcPortAdminMaxIPDUOctetsSend 1.3.6.1.3.51.1.1.1.1.3
This object denotes the default maximum I PDU size, in octets, that LLCs on this port may send to their remote LLC partners. This count is referred to as 'N1' in the IEEE 802.2 specification [??]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxIPDUOctetsSend object or by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcPortAdminMaxIPDUOctetsRcv 1.3.6.1.3.51.1.1.1.1.4
This object denotes the default maximum I PDU size, in octets, that LLCs on this port can expect to receive from their remote LLC partners. This count is referred to as 'N1' in the IEEE 802.2 specification [??] This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxIPDUOctetsRcv object or by a non-zero value in the llcCcAdminMaxIPDUOctetsRcvd object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame. The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcPortAdminMaxUnackedIPDUsSend 1.3.6.1.3.51.1.1.1.1.5
This object denotes the default maximum consequetive unacknowledged I PDU frames that LLCs on this port may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [??]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsSend object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamicly learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcPortAdminMaxUnackedIPDUsRcv 1.3.6.1.3.51.1.1.1.1.6
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this port can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [??]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsRcv object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcvd object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcPortAdminMaxRetransmits 1.3.6.1.3.51.1.1.1.1.7
This object denotes the default value for the maximum number of times which LLCs on this port shall retry a PDU following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [??]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxretransmits object or by a non-zero value in the llcCcAdminMaxRetransmits object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcPortAdminAckTimer 1.3.6.1.3.51.1.1.1.1.8
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). alue in the llcSapAdminAckTimer object or by a non-zero value in the llcCcAdminAckTimer object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminPbitTimer 1.3.6.1.3.51.1.1.1.1.9
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the command with the poll bit to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminPbitTimer object or by a non-zero value in the llcCcAdminPbitTimer object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminRejTimer 1.3.6.1.3.51.1.1.1.1.10
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminRejTimer object or by a non-zero value in the llcCcAdminRejTimer object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminBusyTimer 1.3.6.1.3.51.1.1.1.1.11
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminBusyTimer object or by a non-zero value in the llcCcAdminBusyTimer object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminInactTimer 1.3.6.1.3.51.1.1.1.1.12
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminInactTimer object or by a non-zero value in the llcCcAdminInactTimer object. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminDelayAckCount 1.3.6.1.3.51.1.1.1.1.13
This object denotes the default value for the maximum number of consequetive I PDUs which the LLCs on this port shall receive during the interval defined by llcCcOperDelayTimertime without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminDelayAckCount object or by a non-zero value in the llcCcAdminDelayCount object. A value of one indicates that acknowledgments will be sent immediately and that the value of llcPortAdminDelayAckTimer shall be ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcPortAdminDelayAckTimer 1.3.6.1.3.51.1.1.1.1.14
This object denotes the default value for the time interval during which the LLCs on this port shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminSimRim 1.3.6.1.3.51.1.1.1.1.15
This object controls the support for transmission and receipt of SIM and RIM control frames for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

llcPortOperTable 1.3.6.1.3.51.1.1.2
This table contains current LLC port parameters. Many of these objects have corresponding objects inthe llcPortAdminTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortOperEntry

llcPortOperEntry 1.3.6.1.3.51.1.1.2.1
Currently set parameters for a specific LLC port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcPortOperEntry  

llcPortOperName 1.3.6.1.3.51.1.1.2.1.1
An octet string that describes the physical port to which this interface is currently attached. It has implementation-specific significance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..8)  

llcPortOperISTATUS 1.3.6.1.3.51.1.1.2.1.2
This parameter describes the initial value of the administrative status, ifAdminStatus, of this LLC port at last port start-up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

llcPortOperLastModifyTime 1.3.6.1.3.51.1.1.2.1.3
This object describes the value of sysUpTime when this port definition was last modified. If the port has not been modified, then this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcPortOperLastFailTime 1.3.6.1.3.51.1.1.2.1.4
This object describes the value of sysUpTime when this LLC port last failed. If the port has not failed, then this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcPortOperLastFailCause 1.3.6.1.3.51.1.1.2.1.5
This enumerated object describes the cause of the last failure of this LLC port. If the port has not failed, then this object has a value of undefined(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), physical(2)  

llcPortStatsTable 1.3.6.1.3.51.1.1.3
Each entry in this table contains statistics for a specific LLC port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortStatsEntry

llcPortStatsEntry 1.3.6.1.3.51.1.1.3.1
A list of statistics for an LLC port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcPortStatsEntry  

llcPortStatsPhysicalFailures 1.3.6.1.3.51.1.1.3.1.1
This object reflects the total number of times this port has failed due to its physical media since port startup. At port startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsPollsIn 1.3.6.1.3.51.1.1.3.1.2
This object reflects the total number of polls received by this port since the port was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsPollsOut 1.3.6.1.3.51.1.1.3.1.3
This object reflects the total number of polls sent by this port since the port was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsPollRspsIn 1.3.6.1.3.51.1.1.3.1.4
This object reflects the total number of poll responses received by this port since the port was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsPollRspsOut 1.3.6.1.3.51.1.1.3.1.5
This object reflects the total number of poll responses sent by this port since the port was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsLocalBusies 1.3.6.1.3.51.1.1.3.1.6
This object reflects the total number of times that the local link stations on this port have entered a busy state (RNR). This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsRemoteBusies 1.3.6.1.3.51.1.1.3.1.7
This object reflects the total number of times that the adjacent (i.e. remote) link stations on this port have entered a busy state (RNR). This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsIFramesIn 1.3.6.1.3.51.1.1.3.1.8
This object reflects the total number of I-Frames that have been received by link stations on this port. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsIFramesOut 1.3.6.1.3.51.1.1.3.1.9
This object reflects the total number of I-Frames that have been transmitted by link stations on this port. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsOctetsIn 1.3.6.1.3.51.1.1.3.1.10
This object reflects the total octets received from adjacent link stations on this port. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsOctetsOut 1.3.6.1.3.51.1.1.3.1.11
This object reflects the total octets transmitted to adjacent link stations on this port. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsProtocolErrs 1.3.6.1.3.51.1.1.3.1.12
This object reflects the total number of times that the link stations on this port have deactivated the link as a result of having received a protocol violation from the adjacent link station. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsActivityTOs 1.3.6.1.3.51.1.1.3.1.13
This object reflects the total number of times that the link stations on this port have deactivated the link as a result of no activity on the link. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsRetriesExps 1.3.6.1.3.51.1.1.3.1.14
This object reflects the total number of times that the link stations on this port have deactivated the link as a result of a retry sequence being exhausted. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsRetransmitsIn 1.3.6.1.3.51.1.1.3.1.15
This object reflects the total number of I-Frames retransmitted by remote link stations for all link stations on this port. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsRetransmitsOut 1.3.6.1.3.51.1.1.3.1.16
This object reflects the total number of I-Frames retransmitted by all local link stations on this port. This object is initialized to zero when the port is created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapAdminTable 1.3.6.1.3.51.1.2.1
This table contains objects that can be changed to manage a local SAP. Changing one of these parameters may take effect in the operating SAP immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the llcSapOperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was changed after the interface was started.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapAdminEntry

llcSapAdminEntry 1.3.6.1.3.51.1.2.1.1
A list of configured values for a local SAP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcSapAdminEntry  

llcSapNumber 1.3.6.1.3.51.1.2.1.1.1
The address of this local SAP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

llcSapAdminState 1.3.6.1.3.51.1.2.1.1.2
This parameter controls the desired state of this local SAP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

llcSapAdminMaxIPDUOctetsSend 1.3.6.1.3.51.1.2.1.1.3
This object denotes the default maximum I PDU size, in octets, that LLCs on this SAP may send to their remote connection component partners. This count is referred to as 'N1' in the IEEE 802.2 specification [??]. A zero value for this object indicates that the port default, llcPortAdminMaxIPDUOctetsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcSapAdminMaxIPDUOctetsRcv 1.3.6.1.3.51.1.2.1.1.4
This object denotes the default maximum I PDU size, in octets, that LLCs on this SAP can expect to receive from their remote LLC partners. This count is referred to as 'N1' in the IEEE 802.2 specification [??] A zero value for this object indicates that the port default, llcPortAdminMaxIPDUOctetsRcv, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxIPDUOctetsRcv object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame. The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcSapAdminMaxUnackedIPDUsSend 1.3.6.1.3.51.1.2.1.1.5
This object denotes the default maximum consequetive unacknowledged I PDU frames that LLCs on this SAP may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [??]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamicly learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcSapAdminMaxUnackedIPDUsRcv 1.3.6.1.3.51.1.2.1.1.6
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this SAP can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [??]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsRcv, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcv object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcSapAdminMaxRetransmits 1.3.6.1.3.51.1.2.1.1.7
This object denotes the default value for the maximum number of times that LLCs on this SAP shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, thelink shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [??]. A zero value for this object indicates that the port default, llcPortAdminMaxRetransmits, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxRetransmits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcSapAdminAckTimer 1.3.6.1.3.51.1.2.1.1.8
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminAckTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminAckTimer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminPbitTimer 1.3.6.1.3.51.1.2.1.1.9
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminPbitTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminPbitTimer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminRejTimer 1.3.6.1.3.51.1.2.1.1.10
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminRejTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminRejTimer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminBusyTimer 1.3.6.1.3.51.1.2.1.1.11
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. A zero value for this object indicates that the port default, llcPortAdminBusyTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminBusyTimer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminInactTimer 1.3.6.1.3.51.1.2.1.1.12
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. A zero value for this object indicates that the port default, llcPortAdminInactTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminInactTimer. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminDelayAckCount 1.3.6.1.3.51.1.2.1.1.13
This object denotes the default value for the maximum number of consequetive I PDUs which the LLCs on this SAP shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. A zero value for this object indicates that the port default, llcPortAdminDelayAck, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminDelayAckCount. A value of one indicates that acknowledgments will be sent immediately and that the value of llcSapAdminDelayAckTimer shall be ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcSapAdminDelayAckTimer 1.3.6.1.3.51.1.2.1.1.14
This object denotes the default value for the time interval during which the LLCs on this SAP shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapOperTable 1.3.6.1.3.51.1.2.2
This table contains objects that reflect the current operational parameters of a local SAP. Many of these objects in this table have corresponding objects in the llcSapAdminTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapOperEntry

llcSapOperEntry 1.3.6.1.3.51.1.2.2.1
A list of configured values for a local SAP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcSapOperEntry  

llcSapOperStatus 1.3.6.1.3.51.1.2.2.1.1
This parameter describes the actual state of this local SAP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

llcSapStatsTable 1.3.6.1.3.51.1.2.3
This table contains objects that reflect the current operational parameters of a local SAP. Many of these objects in this table have corresponding objects in the llcSapAdminTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapStatsEntry

llcSapStatsEntry 1.3.6.1.3.51.1.2.3.1
A list of configured values for a local SAP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcSapStatsEntry  

llcSapStatsTESTsIn 1.3.6.1.3.51.1.2.3.1.1
This object reflects the total number of TEST frames (both commands and responses) received on a local SAP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTsOut 1.3.6.1.3.51.1.2.3.1.2
This object reflects the total number of TEST frames (both commands and responses) sent on a local SAP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDsIn 1.3.6.1.3.51.1.2.3.1.3
This object reflects the total number of XID frames (both commands and responses) received on a local SAP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDsOut 1.3.6.1.3.51.1.2.3.1.4
This object reflects the total number of XID frames (both commands and responses) sent on a local SAP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsUIFramesIn 1.3.6.1.3.51.1.2.3.1.5
This object reflects the total number of unnumbered information (UI) frames received on a local SAP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsUIFramesOut 1.3.6.1.3.51.1.2.3.1.6
This object reflects the total number of unnumbered information (UI) frames sent on a local SAP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcAdminTable 1.3.6.1.3.51.1.3.1
This table contains objects that can be changed to manage an LLC link station. Changing one of these parameters may take effect in the operating link immediately or may wait until the link is restarted depending on the details of the implementation. The entries in llcCcAdminTable can be created either by an agent or a management station. The management station can create an entry in llcCcAdminTable by setting the appropriate value in llcCcAdminRowStatus. Most of the objects in this read-create table have corresponding read-only objects in the llcCcOperTable that reflect the current operating value. The operating values may be different from these configured values if changed by XID negotiation or if a configured parameter was changed after the link was started.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcAdminEntry

llcCcAdminEntry 1.3.6.1.3.51.1.3.1.1
A list of configured values for an LLC link station.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcCcAdminEntry  

llcCcLSap 1.3.6.1.3.51.1.3.1.1.1
This value is the address of the local SAP for this Connection Component.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

llcCcRSap 1.3.6.1.3.51.1.3.1.1.2
This value is the address of the remote SAP for this Connection Component.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

llcCcLMac 1.3.6.1.3.51.1.3.1.1.3
This value is the local MAC address for this Connection Component.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

llcCcRMac 1.3.6.1.3.51.1.3.1.1.4
This value is the remote MAC address for this Connection Component.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

llcCcAdminState 1.3.6.1.3.51.1.3.1.1.5
This object controls the desired state of the LLC connection. The managed system shall attempt to keep the operational state, llcCcOperState, consistent with this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

llcCcAdminMaxIPDUOctetsSend 1.3.6.1.3.51.1.3.1.1.6
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [??]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxIPDUOctetsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcCcAdminMaxIPDUOctetsRcv 1.3.6.1.3.51.1.3.1.1.7
This object denotes the maximum I PDU size,in octets, that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'N1' in the IEEE 802.2 specification [??] This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxIPDUOctetsRcv, shall be used. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame. The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcCcAdminMaxUnackedIPDUsSend 1.3.6.1.3.51.1.3.1.1.8
This object denotes the maximum consequetive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [??]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamicly learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcCcAdminMaxUnackedIPDUsRcv 1.3.6.1.3.51.1.3.1.1.9
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [??]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsRcv, shall be used. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcCcAdminMaxRetransmits 1.3.6.1.3.51.1.3.1.1.10
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [??]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxRetransmits, shall be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcCcAdminAckTimer 1.3.6.1.3.51.1.3.1.1.11
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminAckTimer, shall be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcAdminPbitTimer 1.3.6.1.3.51.1.3.1.1.12
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminPbitTimer, shall be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcAdminRejTimer 1.3.6.1.3.51.1.3.1.1.13
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminRejTimer, shall be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcAdminBusyTimer 1.3.6.1.3.51.1.3.1.1.14
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminBusyTimer, shall be used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcAdminInactTimer 1.3.6.1.3.51.1.3.1.1.15
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminInactTimer, shall be used. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcAdminDelayAckCount 1.3.6.1.3.51.1.3.1.1.16
This object denotes the value for the maximum number of consequetive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminDelayAck, shall be used. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcAdminDelayAckTimer shall be ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcCcAdminDelayAckTimer 1.3.6.1.3.51.1.3.1.1.17
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object contains an administrative value which will be applied the next time this connection is established. This object is associated with the llcCcAdminDelayAckCount object and is only defined if that object has a value greater than one.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcAdminRowStatus 1.3.6.1.3.51.1.3.1.1.18
This object is used by a management station to create or delete the row entry in llcCcAdminTable following the RowStatus textual convention. Upon successful creation of the row, an agent automatically creates a corresponding entry in the llcCcOperTable with llcCcOperState equal to 'discontacted (1)'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

llcCcOperTable 1.3.6.1.3.51.1.3.2
This table contains current LLC link parameters. Many of these objects have corresponding objects in the llcCcAdminTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcOperEntry

llcCcOperEntry 1.3.6.1.3.51.1.3.2.1
A list of status and control values for an LLC link station.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcCcOperEntry  

llcCcOperRole 1.3.6.1.3.51.1.3.2.1.1
This object reflects the current role that the link station is assuming.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), undefined(3)  

llcCcOperState 1.3.6.1.3.51.1.3.2.1.2
This object describes the operational state of the LLC connection. The managed system shall attempt to keep this value consistent with the administered state, llcCcAdminState
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER discontacted(1), contactPending(2), contacted(3), discontactPending(4)  

llcCcOperMaxIPDUOctetsSend 1.3.6.1.3.51.1.3.2.1.3
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [??]. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect that in this object. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcCcOperMaxIPDUOctetsRcv 1.3.6.1.3.51.1.3.2.1.4
This object denotes the maximum I PDU size,in octets, that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'N1' in the IEEE 802.2 specification [??] The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Integer32  

llcCcOperMaxUnackedIPDUsSend 1.3.6.1.3.51.1.3.2.1.5
This object denotes the maximum consequetive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [??]. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamicly learned value and should reflect that in this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperMaxUnackedIPDUsRcv 1.3.6.1.3.51.1.3.2.1.6
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [??].
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperMaxRetransmits 1.3.6.1.3.51.1.3.2.1.7
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [??].
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcCcOperAckTimer 1.3.6.1.3.51.1.3.2.1.8
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times).
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcOperPbitTimer 1.3.6.1.3.51.1.3.2.1.9
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcOperRejTimer 1.3.6.1.3.51.1.3.2.1.10
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcOperBusyTimer 1.3.6.1.3.51.1.3.2.1.11
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcOperInactTimer 1.3.6.1.3.51.1.3.2.1.12
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcOperDelayAckCount 1.3.6.1.3.51.1.3.2.1.13
This object denotes the value for the maximum number of consequetive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [??] but is widely implemented. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcOperDelayAckTimer should be ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

llcCcOperDelayAckTimer 1.3.6.1.3.51.1.3.2.1.14
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [??] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcCcOperDelayAckCount object and only has meaning if that object has a value greater than one.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcCcOperCreateTime 1.3.6.1.3.51.1.3.2.1.15
This object describes the value of sysUpTime when this connection was created.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperLastModifyTime 1.3.6.1.3.51.1.3.2.1.16
This object describes the value of sysUpTime when this connection definition was last modified. If the connection has not been modified, then this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperLastFailTime 1.3.6.1.3.51.1.3.2.1.17
This object describes the value of sysUpTime when this LLC link station last failed. If the link station has not failed, then this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperLastFailCause 1.3.6.1.3.51.1.3.2.1.18
This enumerated object reflects the cause of the last failure of this LLC link station. If the link station has not failed, then this object will have a value of undefined(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), rxFRMR(2), txFRMR(3), noResponse(4), protocolErr(5), noActivity(6), discReceived(7), dmReceived(8), retriesExpired(9)  

llcCcOperLastFailFRMRInfo 1.3.6.1.3.51.1.3.2.1.19
This object reflects the information field of the FRMR frame if the last failure for this LLC link station was as a result of an invalid frame. Otherwise, this field has no meaning.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

llcCcStatsTable 1.3.6.1.3.51.1.3.3
Each entry in this table contains statistics for a specific LLC link station.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcStatsEntry

llcCcStatsEntry 1.3.6.1.3.51.1.3.3.1
A list of statistics for an LLC link station.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LlcCcStatsEntry  

llcCcStatsLocalBusies 1.3.6.1.3.51.1.3.3.1.1
This object reflects the total number of times that the local LLC link station has entered a busy state (RNR) since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsRemoteBusies 1.3.6.1.3.51.1.3.3.1.2
This object reflects the total number of times that an adjacent ( remote) LLC link station has entered a busy state (RNR) since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIFramesIn 1.3.6.1.3.51.1.3.3.1.3
This object reflects the total I-frames received from an adjacent LLC link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIFramesOut 1.3.6.1.3.51.1.3.3.1.4
This object reflects the total I-frames transmitted to an adjacent LLC link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIOctetsIn 1.3.6.1.3.51.1.3.3.1.5
This object reflects the total octets contained in I-frames received from an adjacent LLC link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIOctetsOut 1.3.6.1.3.51.1.3.3.1.6
This object reflects the total octets contained in I-frames transmitted to an adjacent LLC link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsREJsIn 1.3.6.1.3.51.1.3.3.1.7
This object reflects the total REJ frames received from an adjacent LLC link station since link station startup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsREJsOut 1.3.6.1.3.51.1.3.3.1.8
This object reflects the total REJ frames transmitted to an adjacent LLC link station since link station startup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsRetransmitsIn 1.3.6.1.3.51.1.3.3.1.9
This object reflects the total number of information frames retransmitted by the remote link station because the N(s) received from that link station indicated that one or more information frames sent by that station were lost. This event causes the first missing information frame of a window and all subsequent information frames to be retransmitted. At link station startup time, this object must be initialized to zero
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsRetransmitsOut 1.3.6.1.3.51.1.3.3.1.10
This object reflects the total number of information frames retransmitted to a remote link station because the N(r) received from that link station indicated that one or more information frames sent to that station were lost. This event causes the first missing information frame of a window and all subsequent information frames to be retransmitted. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsFRMRsIn 1.3.6.1.3.51.1.3.3.1.11
This object reflects the total frame reject (FRMR) frames received from an adjacent LLC link station since link station startup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsFRMRsOut 1.3.6.1.3.51.1.3.3.1.12
This object reflects the total frame reject (FRMR) frames transmitted to an adjacent LLC link station since link station startup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsDISCsIn 1.3.6.1.3.51.1.3.3.1.13
This object reflects the total number of disconnect (DISC) requests received from an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsDISCsOut 1.3.6.1.3.51.1.3.3.1.14
This object reflects the total number of disconnect (DISC) requests transmited to an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsUAsIn 1.3.6.1.3.51.1.3.3.1.15
This object reflects the total number of unnumbered acknowledgements (UA) requests received from an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsUAsOut 1.3.6.1.3.51.1.3.3.1.16
This object reflects the total number of unnumbered acknowledgements (UA) requests transmited to an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsDMsIn 1.3.6.1.3.51.1.3.3.1.17
This object reflects the total number of disconnect mode (DM) requests received from an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsDMsOut 1.3.6.1.3.51.1.3.3.1.18
This object reflects the total number of disconnect mode (DM) requests transmited to an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsSABMEsIn 1.3.6.1.3.51.1.3.3.1.19
This object reflects the total number of set normal response mode (SABME) requests received from an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsSABMEsOut 1.3.6.1.3.51.1.3.3.1.20
This object reflects the total number of set normal response mode (SABME) requests transmited to an adjacent link station since link station startup. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsProtocolErrs 1.3.6.1.3.51.1.3.3.1.21
This object reflects the total occurrences, since link station startup, where this LLC link station has inactivated the link as a result of receiving a frame from its adjacent link station which was in violation of the protocol. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsActivityTOs 1.3.6.1.3.51.1.3.3.1.22
This object reflects the total occurrences, since startup, where this LLC link station has inactivated the link as a result of no activity on the link. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsRetriesExps 1.3.6.1.3.51.1.3.3.1.23
This object reflects the total occurrences, since startup, where this LLC link station has inactivated the link as a result of a retry sequence being exhausted. At link station startup time, this object must be initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatusChange 1
This trap indicates that the state of an LLC port has transitioned to active or inactive.
TRAP-TYPE    

llcCcStatusChange 2
This trap indicates that the state of an LLC link station has transitioned to contacted or discontacted.
TRAP-TYPE    

llcCorePortAdminGroup 1.3.6.1.3.51.1.5.2.1.1
OBJECT IDENTIFIER    

llcCorePortOperGroup 1.3.6.1.3.51.1.5.2.1.2
OBJECT IDENTIFIER    

llcCorePortStatsGroup 1.3.6.1.3.51.1.5.2.1.3
OBJECT IDENTIFIER    

llcCoreCcAdminGroup 1.3.6.1.3.51.1.5.2.1.4
OBJECT IDENTIFIER    

llcCoreCcOperGroup 1.3.6.1.3.51.1.5.2.1.5
OBJECT IDENTIFIER    

llcCoreCcStatsGroup 1.3.6.1.3.51.1.5.2.1.6
OBJECT IDENTIFIER    

llcCoreCompliance 1.3.6.1.3.51.1.5.1.1
OBJECT IDENTIFIER