SONOMASYSTEMS-SONOMA-ATM-IMA-MIB

File: SONOMASYSTEMS-SONOMA-ATM-IMA-MIB.mib (56400 bytes)

Imported modules

RFC1155-SMI RFC-1212 SONOMASYSTEMS-SONOMA-MIB

Imported symbols

Counter OBJECT-TYPE sonomaATM

Defined Types

ImaGroupEntry  
SEQUENCE    
  imaGroupIndex INTEGER
  imaGroupRowStatus INTEGER
  imaGroupIfIndex INTEGER
  imaGroupNeState INTEGER
  imaGroupFeState INTEGER
  imaGroupFailureStatus INTEGER
  imaGroupSymmetry INTEGER
  imaGroupMinNumTxLinks INTEGER
  imaGroupMinNumRxLinks INTEGER
  imaGroupNeTxClkMode INTEGER
  imaGroupFeTxClkMode INTEGER
  imaGroupTxTimingRefLink INTEGER
  imaGroupRxTimingRefLink INTEGER
  imaGroupLastChange INTEGER
  imaGroupTxImaId INTEGER
  imaGroupRxImaId INTEGER
  imaGroupTxFrameLength INTEGER
  imaGroupRxFrameLength INTEGER
  imaGroupDiffDelayMax INTEGER
  imaGroupLeastDelayLink INTEGER
  imaGroupDiffDelayMaxObs INTEGER
  imaGroupAlphaValue INTEGER
  imaGroupBetaValue INTEGER
  imaGroupGammaValue INTEGER
  imaGroupRunningSecs INTEGER
  imaGroupUnavailSecs INTEGER
  imaGroupNeNumFailures INTEGER
  imaGroupFeNumFailures INTEGER
  imaGroupTxAvailCellRate INTEGER
  imaGroupRxAvailCellRate INTEGER
  imaGroupNumTxCfgLnks INTEGER
  imaGroupNumRxCfgLnks INTEGER
  imaGroupNumTxActLnks INTEGER
  imaGroupNumRxActLnks INTEGER
  imaGroupTestLinkIfIndex INTEGER
  imaGroupTestPattern INTEGER
  imaGroupTestProcStatus INTEGER

ImaLinkEntry  
SEQUENCE    
  imaLinkIfIndex INTEGER
  imaLinkRowStatus INTEGER
  imaLinkGroupIndex INTEGER
  imaLinkNeTxState INTEGER
  imaLinkNeRxState INTEGER
  imaLinkFeTxState INTEGER
  imaLinkFeRxState INTEGER
  imaLinkNeRxFailureStatus INTEGER
  imaLinkFeRxFailureStatus INTEGER
  imaLinkTxLid INTEGER
  imaLinkRxLid INTEGER
  imaLinkRelDelay INTEGER
  imaLinkImaViolations INTEGER
  imaLinkOifAnomalies INTEGER
  imaLinkNeSevErroredSec INTEGER
  imaLinkFeSevErroredSec INTEGER
  imaLinkNeUnavailSec INTEGER
  imaLinkFeUnavailSec INTEGER
  imaLinkNeTxUnusableSec INTEGER
  imaLinkNeRxUnusableSec INTEGER
  imaLinkFeTxUnusableSec INTEGER
  imaLinkFeRxUnusableSec INTEGER
  imaLinkNeTxNumFailures INTEGER
  imaLinkNeRxNumFailures INTEGER
  imaLinkFeTxNumFailures INTEGER
  imaLinkFeRxNumFailures INTEGER
  imaLinkTxStuffs INTEGER
  imaLinkRxStuffs INTEGER
  imaLinkRxTestPattern INTEGER
  imaLinkTestProcStatus INTEGER
  imaLinkNumber INTEGER

ImaDs1Entry  
SEQUENCE    
  imaDs1Index INTEGER
  imaDs1GroupIndex INTEGER
  imaDs1ConfLoopback INTEGER
  imaDs1ConfTxClockSelect INTEGER
  imaDs1ConfLineCode INTEGER
  imaDs1ConfFrameFormat INTEGER
  imaDs1ConfCableLength INTEGER
  imaDs1ConfTxTimingRefLink INTEGER
  imaDs1ConfScramble INTEGER
  imaDs1StatsNoSignals Counter
  imaDs1StatsAISDetects Counter
  imaDs1StatsYelAlarmCount Counter
  imaDs1StatsLCVErrors Counter
  imaDs1StatsPCVErrors Counter
  imaDs1StatsMOSErrors Counter
  imaDs1StatsSyncLossCount Counter
  imaDs1StatsHECErrors Counter
  imaDs1StatsSignalLoss INTEGER
  imaDs1StatsAISDetect INTEGER
  imaDs1StatsYellowAlarm INTEGER
  imaDs1StatsSyncLoss INTEGER
  imaDs1StatsTxClockLoss INTEGER
  imaDs1StatsErrSec Counter
  imaDs1StatsLineErrSec Counter
  imaDs1StatsErrFreeSec Counter
  imaDs1StatsBurstErrSec Counter
  imaDs1StatsSevErrSec Counter
  imaDs1StatsConSevErrSec Counter
  imaDs1StatsFailedSignal Counter
  imaDs1StatsUnavailSec Counter
  imaDs1StatsSevErrFramSec Counter
  imaDs1StatsClearCounters INTEGER
  imaDs1DebugAddr INTEGER
  imaDs1DebugReadValue INTEGER
  imaDs1DebugWriteValue INTEGER
  imaDs1DebugRead INTEGER
  imaDs1PortNumber INTEGER

ImaE1Entry  
SEQUENCE    
  imaE1Index INTEGER
  imaE1GroupIndex INTEGER
  imaE1ConfLoopback INTEGER
  imaE1ConfTxClockSelect INTEGER
  imaE1ConfLineCode INTEGER
  imaE1ConfFrameFormat INTEGER
  imaE1ConfCableLength INTEGER
  imaE1ConfTxTimingRefLink INTEGER
  imaE1ConfScramble INTEGER
  imaE1StatsNoSignals Counter
  imaE1StatsRAIDetects Counter
  imaE1StatsFASErrors Counter
  imaE1StatsCVErrors Counter
  imaE1StatsCRCErrors Counter
  imaE1StatsEBitErrors Counter
  imaE1StatsSyncLossCount Counter
  imaE1StatsHECErrors Counter
  imaE1StatsSignalLoss INTEGER
  imaE1StatsRAIDetect INTEGER
  imaE1StatsSyncLoss INTEGER
  imaE1StatsTxClockLoss INTEGER
  imaE1StatsErrSec Counter
  imaE1StatsLineErrSec Counter
  imaE1StatsErrFreeSec Counter
  imaE1StatsBurstErrSec Counter
  imaE1StatsSevErrSec Counter
  imaE1StatsConSevErrSec Counter
  imaE1StatsFailedSignal Counter
  imaE1StatsUnavailSec Counter
  imaE1StatsSevErrFramSec Counter
  imaE1StatsClearCounters INTEGER
  imaE1DebugAddr INTEGER
  imaE1DebugReadValue INTEGER
  imaE1DebugWriteValue INTEGER
  imaE1DebugRead INTEGER
  imaE1PortNumber INTEGER

Defined Values

sonomaImaATMAdapterGroup 1.3.6.1.4.1.2926.25.7.7
OBJECT IDENTIFIER    

atmImaGroupObjects 1.3.6.1.4.1.2926.25.7.7.1
OBJECT IDENTIFIER    

atmImaLinkObjects 1.3.6.1.4.1.2926.25.7.7.2
OBJECT IDENTIFIER    

atmImaDs1Objects 1.3.6.1.4.1.2926.25.7.7.3
OBJECT IDENTIFIER    

atmImaE1Objects 1.3.6.1.4.1.2926.25.7.7.4
OBJECT IDENTIFIER    

imaGroupNumber 1.3.6.1.4.1.2926.25.7.7.1.1
The number of IMA groups configured on this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupTable 1.3.6.1.4.1.2926.25.7.7.1.2
The IMA Group Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ImaGroupEntry

imaGroupEntry 1.3.6.1.4.1.2926.25.7.7.1.2.1
An entry in the IMA Group table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ImaGroupEntry  

imaGroupIndex 1.3.6.1.4.1.2926.25.7.7.1.2.1.1
A unique value for the IMA Group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupRowStatus 1.3.6.1.4.1.2926.25.7.7.1.2.1.2
This object identifies the IMA Group's administrative status. It is used to enable and disable a group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

imaGroupIfIndex 1.3.6.1.4.1.2926.25.7.7.1.2.1.3
This object identifies the logical interface number ('ifIndex') assigned to this IMA group, and is used to identify corresponding rows in the Interfaces MIB. Note that re-initialization of the management agent may cause a client's 'imaGroupIfIndex' to change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupNeState 1.3.6.1.4.1.2926.25.7.7.1.2.1.4
The current operational state of the near-end IMA Group State Machine.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConfigured(1), startUp(2), startUpAck(3), configAbortUnsupportedM(4), configAbortIncompatibleSymmetry(5), configAbortOther(6), insufficientLinks(7), blocked(8), operational(9)  

imaGroupFeState 1.3.6.1.4.1.2926.25.7.7.1.2.1.5
The current operational state of the far-end IMA Group State Machine.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConfigured(1), startUp(2), startUpAck(3), configAbortUnsupportedM(4), configAbortIncompatibleSymmetry(5), configAbortOther(6), insufficientLinks(7), blocked(8), operational(9)  

imaGroupFailureStatus 1.3.6.1.4.1.2926.25.7.7.1.2.1.6
The current failure status of the IMA group (the reason why the GTSM is in the down state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noFailure(1), startUpNe(2), startUpFe(3), invalidMValueNe(4), invalidMValueFe(5), failedAssymetricNe(6), failedAssymetricFe(7), insufficientLinksNe(8), insufficientLinksFe(9), blockedNe(10), blockedFe(11), otherFailure(12)  

imaGroupSymmetry 1.3.6.1.4.1.2926.25.7.7.1.2.1.7
Symmetry of the IMA group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER symmetricOperation(1), asymmetricOperation(2), asymmetricConfiguration(3)  



imaGroupNeTxClkMode 1.3.6.1.4.1.2926.25.7.7.1.2.1.10
Transmit clocking mode used by the near-end IMA group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ctc(1), itc(2)  

imaGroupFeTxClkMode 1.3.6.1.4.1.2926.25.7.7.1.2.1.11
Transmit clocking mode used by the far-end IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ctc(1), itc(2)  



imaGroupLastChange 1.3.6.1.4.1.2926.25.7.7.1.2.1.14
The time-of-day the IMA group last changed operational state (i.e., value of imaNeGroupState changed).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupTxImaId 1.3.6.1.4.1.2926.25.7.7.1.2.1.15
The IMA ID currently in use by the near-end IMA function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

imaGroupRxImaId 1.3.6.1.4.1.2926.25.7.7.1.2.1.16
The IMA ID currently in use by the far-end IMA function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

imaGroupTxFrameLength 1.3.6.1.4.1.2926.25.7.7.1.2.1.17
The frame length to be used by the IMA group in the transmit direction. Can only be set when the IMA group is startup.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER m32(32), m64(64), m128(128), m256(256)  

imaGroupRxFrameLength 1.3.6.1.4.1.2926.25.7.7.1.2.1.18
Value of IMA frame length as received from remote IMA function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER m32(32), m64(64), m128(128), m256(256)  

imaGroupDiffDelayMax 1.3.6.1.4.1.2926.25.7.7.1.2.1.19
The maximum number of milliseconds of delay differential among the links that will be tolerated on this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  


imaGroupDiffDelayMaxObs 1.3.6.1.4.1.2926.25.7.7.1.2.1.21
The latest maximum differential delay observed (in milliseconds), i.e. between the links having the least and most link propagation delay, among the receive links that are currently configured in the IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupAlphaValue 1.3.6.1.4.1.2926.25.7.7.1.2.1.22
This indicates the 'alpha' value used to specify the number of consecutive invalid ICP cells to be detected before moving to the IMA HUNT state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2  

imaGroupBetaValue 1.3.6.1.4.1.2926.25.7.7.1.2.1.23
This indicates the 'beta' value used to specify the number of consecutive errored ICP cells to be detected before moving to the IMA HUNT state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

imaGroupGammaValue 1.3.6.1.4.1.2926.25.7.7.1.2.1.24
This indicates the 'gamma' value used to specify the number of consecutive valid ICP cells to be detected before moving to the IMA SYNC state from the PRESYNC state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

imaGroupRunningSecs 1.3.6.1.4.1.2926.25.7.7.1.2.1.25
The amount of time (in seconds) since this IMA group has been in operation (up or down).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupUnavailSecs 1.3.6.1.4.1.2926.25.7.7.1.2.1.26
Count of one second intervals where the IMA Group Traffic State Machine is Down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupNeNumFailures 1.3.6.1.4.1.2926.25.7.7.1.2.1.27
The number of times a near-end group failure (Config-Abort, Insufficient-Links) has been reported since power-up or reboot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupFeNumFailures 1.3.6.1.4.1.2926.25.7.7.1.2.1.28
The number of times a far-end group failure (Config-Abort-FE, Insufficient-Links-FE, Blocked-FE) has been reported since power-up or reboot. This is an optional attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupTxAvailCellRate 1.3.6.1.4.1.2926.25.7.7.1.2.1.29
The current cell rate (truncated value in cells per second) provided by this IMA group in the transmit direction, considering all the transmit links in the Active state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupRxAvailCellRate 1.3.6.1.4.1.2926.25.7.7.1.2.1.30
The current cell rate (truncated value in cells per second) provided by this IMA group in the receive direction, considering all the receive links in the Active state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupNumTxCfgLnks 1.3.6.1.4.1.2926.25.7.7.1.2.1.31
The number of links that are configured to transmit in this IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupNumRxCfgLnks 1.3.6.1.4.1.2926.25.7.7.1.2.1.32
The number of links that are configured to receive in this IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupNumTxActLnks 1.3.6.1.4.1.2926.25.7.7.1.2.1.33
The number of links which are configured to transmit and are currently Active in this IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupNumRxActLnks 1.3.6.1.4.1.2926.25.7.7.1.2.1.34
The number of links which are configured to receive and are currently Active in this IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaGroupTestLinkIfIndex 1.3.6.1.4.1.2926.25.7.7.1.2.1.35
This object is used to designate an interface as the Test Link. A value of -1 specifies that the implementation may choose the Test Link. In this case, the implementation may also choose the value of 'imaGroupTestPattern'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaGroupTestPattern 1.3.6.1.4.1.2926.25.7.7.1.2.1.36
The value of this object is used to specify the test pattern in an IMA group loopback operation. A value in the range 0 to 255 designates a specific pattern. A value of -1 specifies that the implementation may choose the value. In this case, the implementation may also choose the value of 'imaGroupTestLinkIfIndex'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaGroupTestProcStatus 1.3.6.1.4.1.2926.25.7.7.1.2.1.37
This object is used to enable or disable the Test Pattern Procedure, and to note whether at least one link failed the test. The test is started by setting operating(2) status. If any link should fail the test, the IMA will set the status to linkfail(3). The linkfail(3) state will persist until either the disabled(1) state is set or until no instance of imaLinkTestProcStatus has the value linkfail(3). Only the values disabled(1) and operating(2) may be written. Writing the operating(2) value will not cause clearing of the linkfail(3) state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), operating(2), linkFail(3)  

imaLinkTable 1.3.6.1.4.1.2926.25.7.7.2.1
The IMA group Link Status and Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ImaLinkEntry

imaLinkEntry 1.3.6.1.4.1.2926.25.7.7.2.1.1
An entry in the IMA Group Link table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ImaLinkEntry  

imaLinkIfIndex 1.3.6.1.4.1.2926.25.7.7.2.1.1.1
This corresponds to the 'ifIndex' of the MIB-II interface on which this link is established. This object also corresponds to the logical number ('ifIndex') assigned to this IMA link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkRowStatus 1.3.6.1.4.1.2926.25.7.7.2.1.1.2
The imaLinkRowStatus object allows create, change and delete operations on imaLinkTable entries. To create a new conceptual row (or instance) of the imaLinkTable, imaLinkRowStatus must be set to 'createAndWait' or 'createAndGo.' A successful set of the object imaLinkGroupIndex must be performed before the RowStatus of this new row can transition to the 'Active' state. The imaLinkGroupIndex provides the association between a physical IMA link to an IMA group. To change (modify) an imaLinkTable entry, the imaLinkRowStatus object must be set to 'notInService'. Only then can the conceptual row be changed. Setting object imaLinkGroupIndex to a different value has the effect of changing the association between a physical IMA link and an IMA group. To place the link 'in group', the imaLinkRowStatus object is set to 'Active'. While the row is not in 'Active' state, both the Transmit and Receive IMA state machines are in the 'Not In Group' state. To remove (delete) an imaLinkTable entry from this table, set this object to 'destroy.' A network manager may elect to perform a delete operation followed immediately by a create operation instead of a modify operation. The net effect of the delete/create is to re-instantiate (reset) agent counters defined in this table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

imaLinkGroupIndex 1.3.6.1.4.1.2926.25.7.7.2.1.1.3
The value which identifies the IMA group (imaGroupIndex) of which this link is a member.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER imaGroup-1(1), none(2)  

imaLinkNeTxState 1.3.6.1.4.1.2926.25.7.7.2.1.1.4
The current state of the near-end transmit link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoGivenReason(2), unusableFault(3), unusableMisconnected(4), unusableBlocked(5), unusableFailed(6), usable(7), active(8)  

imaLinkNeRxState 1.3.6.1.4.1.2926.25.7.7.2.1.1.5
The current state of the near-end receive link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoGivenReason(2), unusableFault(3), unusableMisconnected(4), unusableBlocked(5), unusableFailed(6), usable(7), active(8)  

imaLinkFeTxState 1.3.6.1.4.1.2926.25.7.7.2.1.1.6
The current state of the far-end transmit link as reported via ICP cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoGivenReason(2), unusableFault(3), unusableMisconnected(4), unusableBlocked(5), unusableFailed(6), usable(7), active(8)  

imaLinkFeRxState 1.3.6.1.4.1.2926.25.7.7.2.1.1.7
The current state of the far-end receive link as reported via ICP cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInGroup(1), unusableNoGivenReason(2), unusableFault(3), unusableMisconnected(4), unusableBlocked(5), unusableFailed(6), usable(7), active(8)  

imaLinkNeRxFailureStatus 1.3.6.1.4.1.2926.25.7.7.2.1.1.8
The current link failure status of the near-end receive link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noFailure(1), imaLinkFailure(2), lifFailure(3), lodsFailure(4), misConnected(5), blocked(6), fault(7), farEndTxLinkUnusable(8), farEndRxLinkUnusable(9)  

imaLinkFeRxFailureStatus 1.3.6.1.4.1.2926.25.7.7.2.1.1.9
The current link failure status of the far-end receive link as reported via ICP cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noFailure(1), imaLinkFailure(2), lifFailure(3), lodsFailure(4), misConnected(5), blocked(6), fault(7), farEndTxLinkUnusable(8), farEndRxLinkUnusable(9)  

imaLinkTxLid 1.3.6.1.4.1.2926.25.7.7.2.1.1.10
The outgoing LID used currently on the link by the local end. This value has meaning only if the link belongs to an IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

imaLinkRxLid 1.3.6.1.4.1.2926.25.7.7.2.1.1.11
The incoming LID used currently on the link by the remote end as reported via ICP cells. This value has meaning only if the link belongs to an IMA group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

imaLinkRelDelay 1.3.6.1.4.1.2926.25.7.7.2.1.1.12
The latest measured delay on this link relative to the link, in the same IMA group, with the least delay.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkImaViolations 1.3.6.1.4.1.2926.25.7.7.2.1.1.13
ICP violations: count of errored, invalid or missing ICP cells during non-SES-IMA condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkOifAnomalies 1.3.6.1.4.1.2926.25.7.7.2.1.1.14
The number of OIF anomalies during non-SES-IMA condition at the near-end. This is an optional attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkNeSevErroredSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.15
Count of one second intervals containing several IV-IMA, or one or more link defects (e.g., LOS, OOF/LOF, AIS, LCD), LIF, LODS defects during non-UAS-IMA condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkFeSevErroredSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.16
Count of one second intervals containing one or more RDI-IMA defects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkNeUnavailSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.17
Count of unavailable seconds at near-end: unavailability begins at the onset of 10 contiguous SES-IMA and ends at the onset of 10 contiguous seconds with no SES-IMA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkFeUnavailSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.18
Count of unavailable seconds at far-end: unavailability begins at the onset of 10 contiguous SES-IMA-FE and ends at the onset of 10 contiguous seconds with no SES-IMA-FE.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkNeTxUnusableSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.19
Tx Unusable seconds: count of Unusable seconds at the near end Tx LSM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkNeRxUnusableSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.20
Rx Unusable seconds: count of Unusable seconds at the near end Rx LSM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkFeTxUnusableSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.21
Tx Unusable seconds at far-end: count of seconds with Unusable indications from the far-end Tx LSM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkFeRxUnusableSec 1.3.6.1.4.1.2926.25.7.7.2.1.1.22
Rx Unusable seconds at far-end: count of seconds with Unusable indications from the far-end Rx LSM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkNeTxNumFailures 1.3.6.1.4.1.2926.25.7.7.2.1.1.23
The number of times a near-end transmit failure alarm condition has been entered on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkNeRxNumFailures 1.3.6.1.4.1.2926.25.7.7.2.1.1.24
The number of times a near-end receive failure alarm condition has been entered on this link (i.e., LIF, LODS, Mis-Connected, RDI-IMA).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkFeTxNumFailures 1.3.6.1.4.1.2926.25.7.7.2.1.1.25
The number of times a far-end transmit failure alarm condition has been entered on this link. This is an optional attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkFeRxNumFailures 1.3.6.1.4.1.2926.25.7.7.2.1.1.26
The number of times a far-end receive failure alarm condition has been entered on this link (i.e., LIF, LODS, Mis-Connected, RDI-IMA). This is an optional attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkTxStuffs 1.3.6.1.4.1.2926.25.7.7.2.1.1.27
Counts of stuff events inserted in the transmit direction. This is an optional attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkRxStuffs 1.3.6.1.4.1.2926.25.7.7.2.1.1.28
Counts of stuff events detected in the receive direction. This is an optional attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaLinkRxTestPattern 1.3.6.1.4.1.2926.25.7.7.2.1.1.29
This object identifies the test pattern received in the ICP Cell (octet 17) on the link during the IMA Test Pattern Procedure. This value then may be compared to the transmitted test pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

imaLinkTestProcStatus 1.3.6.1.4.1.2926.25.7.7.2.1.1.30
This value indicates the current state of the Test Pattern Procedure. If the value is disabled(1), the test is not running. A value of operating(2) means the test is running and no error has been found on this interface. A value of linkfail(3) means an error has been detected o this link during the test. Once an error occurs, the linkfail(3) value is latched until either this object is read or until the imaGroupTestProcStatus is moved to disabled(1). Once read, if the error no longer persists, a subsequent read will report the value operating(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), operating(2), linkFail(3)  

imaLinkNumber 1.3.6.1.4.1.2926.25.7.7.2.1.1.31
This corresponds to the link number on the IMA Group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaDs1Table 1.3.6.1.4.1.2926.25.7.7.3.1
A table of physical layer configuration for the DS1 interface
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ImaDs1Entry

imaDs1Entry 1.3.6.1.4.1.2926.25.7.7.3.1.1
A entry in the table, containing information about the physical layer of a DS1 interface
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ImaDs1Entry  

imaDs1Index 1.3.6.1.4.1.2926.25.7.7.3.1.1.1
The physical interface index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaDs1GroupIndex 1.3.6.1.4.1.2926.25.7.7.3.1.1.2
The IMA Group's interface index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaDs1ConfLoopback 1.3.6.1.4.1.2926.25.7.7.3.1.1.3
This object is used to modify the state of internal loopback....
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), payload(2), line(3), local(4)  

imaDs1ConfTxClockSelect 1.3.6.1.4.1.2926.25.7.7.3.1.1.4
Configure the transmit clock.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), recovered(2)  

imaDs1ConfLineCode 1.3.6.1.4.1.2926.25.7.7.3.1.1.5
Configure the line coding method.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER b8zs(1), ami(2)  

imaDs1ConfFrameFormat 1.3.6.1.4.1.2926.25.7.7.3.1.1.6
Configure the framing format.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sf(1), esf(2)  

imaDs1ConfCableLength 1.3.6.1.4.1.2926.25.7.7.3.1.1.7
Configure the cable length.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER short-haul-0-133-FT(1), short-haul-133-266-FT(2), short-haul-266-399-FT(3), short-haul-399-533-FT(4), short-haul-533-655-FT(5), long-haul-0-0-dB(6), long-haul-7-5-dB(7), long-haul-15-0-dB(8), long-haul-22-5-dB(9)  


imaDs1ConfScramble 1.3.6.1.4.1.2926.25.7.7.3.1.1.9
The cells are scrambled / de-scrambled on the line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

imaDs1StatsNoSignals 1.3.6.1.4.1.2926.25.7.7.3.1.1.10
No signal error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsAISDetects 1.3.6.1.4.1.2926.25.7.7.3.1.1.11
AIS Detect counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsYelAlarmCount 1.3.6.1.4.1.2926.25.7.7.3.1.1.12
A count of the number of Yellow Alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsLCVErrors 1.3.6.1.4.1.2926.25.7.7.3.1.1.13
LCV (Line Code Violation) error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsPCVErrors 1.3.6.1.4.1.2926.25.7.7.3.1.1.14
PCV (Path Code Violation) error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsMOSErrors 1.3.6.1.4.1.2926.25.7.7.3.1.1.15
Multiframe out of sync error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsSyncLossCount 1.3.6.1.4.1.2926.25.7.7.3.1.1.16
Sync Loss counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsHECErrors 1.3.6.1.4.1.2926.25.7.7.3.1.1.17
HEC error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsSignalLoss 1.3.6.1.4.1.2926.25.7.7.3.1.1.18
Signal loss indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaDs1StatsAISDetect 1.3.6.1.4.1.2926.25.7.7.3.1.1.19
AIS indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaDs1StatsYellowAlarm 1.3.6.1.4.1.2926.25.7.7.3.1.1.20
Yellow Alarm indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaDs1StatsSyncLoss 1.3.6.1.4.1.2926.25.7.7.3.1.1.21
Loss of sync indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaDs1StatsTxClockLoss 1.3.6.1.4.1.2926.25.7.7.3.1.1.22
Loss of transmit clock indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaDs1StatsErrSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.23
Count of Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsLineErrSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.24
Count of Line Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsErrFreeSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.25
Count of Error Free Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsBurstErrSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.26
Count of Bursty Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsSevErrSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.27
Count of Severely Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsConSevErrSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.28
Count of Consecutive Severely Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsFailedSignal 1.3.6.1.4.1.2926.25.7.7.3.1.1.29
Count of Failed Signal conditions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsUnavailSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.30
Count of unavailable secondss.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsSevErrFramSec 1.3.6.1.4.1.2926.25.7.7.3.1.1.31
Count of Severely Errored Framing Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaDs1StatsClearCounters 1.3.6.1.4.1.2926.25.7.7.3.1.1.32
Clear all counters in this group ONLY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaDs1DebugAddr 1.3.6.1.4.1.2926.25.7.7.3.1.1.33
PCI Phy address for DS1 port register.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaDs1DebugReadValue 1.3.6.1.4.1.2926.25.7.7.3.1.1.34
Value read from DS1 port register.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaDs1DebugWriteValue 1.3.6.1.4.1.2926.25.7.7.3.1.1.35
Value written to DS1 port register.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaDs1DebugRead 1.3.6.1.4.1.2926.25.7.7.3.1.1.36
Read or Write of DS1 port register (TRUE = READ).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaDs1PortNumber 1.3.6.1.4.1.2926.25.7.7.3.1.1.37
The port number on the IMA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaE1Table 1.3.6.1.4.1.2926.25.7.7.4.1
A table of physical layer configuration for the E1 interface
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ImaE1Entry

imaE1Entry 1.3.6.1.4.1.2926.25.7.7.4.1.1
A entry in the table, containing information about the physical layer of a E1 interface
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ImaE1Entry  

imaE1Index 1.3.6.1.4.1.2926.25.7.7.4.1.1.1
The physical interface index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaE1GroupIndex 1.3.6.1.4.1.2926.25.7.7.4.1.1.2
The IMA Group's interface index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imaE1ConfLoopback 1.3.6.1.4.1.2926.25.7.7.4.1.1.3
This object is used to modify the state of internal loopback....
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), internal(2), external(3)  

imaE1ConfTxClockSelect 1.3.6.1.4.1.2926.25.7.7.4.1.1.4
Configure the transmit clock.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), recovered(2)  

imaE1ConfLineCode 1.3.6.1.4.1.2926.25.7.7.4.1.1.5
Configure the line coding method.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hdb3(1), ami(2)  

imaE1ConfFrameFormat 1.3.6.1.4.1.2926.25.7.7.4.1.1.6
Configure the framing format.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER crc4-enabled(1), crc4-disabled(2)  

imaE1ConfCableLength 1.3.6.1.4.1.2926.25.7.7.4.1.1.7
Configure Long or Short Haul.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER short-haul(1), long-haul(2), long-haul-75(3)  


imaE1ConfScramble 1.3.6.1.4.1.2926.25.7.7.4.1.1.9
The cells are scrambled / de-scrambled on the line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

imaE1StatsNoSignals 1.3.6.1.4.1.2926.25.7.7.4.1.1.10
No signal error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsRAIDetects 1.3.6.1.4.1.2926.25.7.7.4.1.1.11
RAI Detect counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsFASErrors 1.3.6.1.4.1.2926.25.7.7.4.1.1.12
FAS (Frame Alignment Signal) error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsCVErrors 1.3.6.1.4.1.2926.25.7.7.4.1.1.13
CV (Code Violation) error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsCRCErrors 1.3.6.1.4.1.2926.25.7.7.4.1.1.14
CRC4 error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsEBitErrors 1.3.6.1.4.1.2926.25.7.7.4.1.1.15
E-Bit (FEBE) error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsSyncLossCount 1.3.6.1.4.1.2926.25.7.7.4.1.1.16
Sync Loss counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsHECErrors 1.3.6.1.4.1.2926.25.7.7.4.1.1.17
HEC error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsSignalLoss 1.3.6.1.4.1.2926.25.7.7.4.1.1.18
Signal loss indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaE1StatsRAIDetect 1.3.6.1.4.1.2926.25.7.7.4.1.1.19
RAI indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaE1StatsSyncLoss 1.3.6.1.4.1.2926.25.7.7.4.1.1.20
Loss of sync indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaE1StatsTxClockLoss 1.3.6.1.4.1.2926.25.7.7.4.1.1.21
Loss of transmit clock indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaE1StatsErrSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.22
Count of Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsLineErrSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.23
Count of Line Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsErrFreeSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.24
Count of Error Free Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsBurstErrSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.25
Count of Bursty Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsSevErrSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.26
Count of Severely Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsConSevErrSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.27
Count of Consecutive Severely Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsFailedSignal 1.3.6.1.4.1.2926.25.7.7.4.1.1.28
Count of Failed Signal conditions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsUnavailSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.29
Count of unavailable secondss.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsSevErrFramSec 1.3.6.1.4.1.2926.25.7.7.4.1.1.30
Count of Severely Errored Framing Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imaE1StatsClearCounters 1.3.6.1.4.1.2926.25.7.7.4.1.1.31
Clear all counters in this group ONLY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

imaE1DebugAddr 1.3.6.1.4.1.2926.25.7.7.4.1.1.32
PCI Phy address for E1 port register.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaE1DebugReadValue 1.3.6.1.4.1.2926.25.7.7.4.1.1.33
Value read from E1 port register.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaE1DebugWriteValue 1.3.6.1.4.1.2926.25.7.7.4.1.1.34
Value written to E1 port register.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaE1DebugRead 1.3.6.1.4.1.2926.25.7.7.4.1.1.35
Read or Write of E1 port register (TRUE = READ).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

imaE1PortNumber 1.3.6.1.4.1.2926.25.7.7.4.1.1.36
The port number on the IMA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER