STONESOFT-NETNODE-MIB

File: STONESOFT-NETNODE-MIB.mib (10705 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
STONESOFT-SMI-MIB

Imported symbols

Unsigned32 Integer32 MODULE-IDENTITY
OBJECT-TYPE NOTIFICATION-TYPE DisplayString
TimeStamp DateAndTime OBJECT-GROUP
NOTIFICATION-GROUP MODULE-COMPLIANCE stonesoftModules
stonesoftNetworkNode

Defined Types

NodeTestEntry  
SEQUENCE    
  nodeTestIndex Unsigned32
  nodeTestIdentity DisplayString
  nodeTestResult INTEGER
  nodeTestResultTime TimeStamp

Defined Values

stonesoftNetworkNodeMibModule 1.3.6.1.4.1.1369.3.4
MIB for generic network nodes
MODULE-IDENTITY    

netNodeObjects 1.3.6.1.4.1.1369.6.1.1
OBJECT IDENTIFIER    

netNodeEvents 1.3.6.1.4.1.1369.6.1.2
OBJECT IDENTIFIER    

netNodeEventsV2 1.3.6.1.4.1.1369.6.1.2.0
OBJECT IDENTIFIER    

netNodeConformance 1.3.6.1.4.1.1369.6.1.3
OBJECT IDENTIFIER    

nodeClusterId 1.3.6.1.4.1.1369.6.1.1.1
The identification number of the cluster this node belongs to
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

nodeMemberId 1.3.6.1.4.1.1369.6.1.1.2
Node's member identification within the cluster
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..16  

nodeOperState 1.3.6.1.4.1.1369.6.1.1.3
The operative (clustering) state of the node
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), online(1), goingOnline(2), lockedOnline(3), goingLockedOnline(4), offline(5), goingOffline(6), lockedOffline(7), goingLockedOffline(8), standby(9), goingStandby(10)  

nodeCPULoad 1.3.6.1.4.1.1369.6.1.1.4
The CPU load percentage on the node
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

nodeLastLogin 1.3.6.1.4.1.1369.6.1.1.5
The most recent login event on the node
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeLastLoginTime 1.3.6.1.4.1.1369.6.1.1.6
Timestamp of the most recent login event on the node
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

nodeHwmonEvent 1.3.6.1.4.1.1369.6.1.1.8
Reason for the hardware monitoring event
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeApplianceModel 1.3.6.1.4.1.1369.6.1.1.9
Appliance model name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeSerialNumber 1.3.6.1.4.1.1369.6.1.1.10
Appliance serial number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

nodePosCode 1.3.6.1.4.1.1369.6.1.1.11
Appliance POS code
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeLoginTime 1.3.6.1.4.1.1369.6.1.1.12
The most recent login event on the node
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

nodePolicyApplyTime 1.3.6.1.4.1.1369.6.1.1.13
The time when the security policy was installed to the node
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

nodeTestTable 1.3.6.1.4.1.1369.6.1.1.7
This table contains an entry for each test instance that was configured to send a trap on test failure
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NodeTestEntry

nodeTestEntry 1.3.6.1.4.1.1369.6.1.1.7.1
Row for a test instance
Status: current Access: not-accessible
OBJECT-TYPE    
  NodeTestEntry  

nodeTestIndex 1.3.6.1.4.1.1369.6.1.1.7.1.1
Unique positive integer index of the nodeTest instance
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65535  

nodeTestIdentity 1.3.6.1.4.1.1369.6.1.1.7.1.2
Identification string of a nodeTest
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

nodeTestResult 1.3.6.1.4.1.1369.6.1.1.7.1.3
The most recent result of the nodeTest
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER success(1), failure(2)  

nodeTestResultTime 1.3.6.1.4.1.1369.6.1.1.7.1.4
The timestamp of the most recent result of the nodeTest
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

nodeOnline 1.3.6.1.4.1.1369.6.1.2.0.1
A node has gone to an online state
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeOffline 1.3.6.1.4.1.1369.6.1.2.0.2
A node has gone to an offline or standby state
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeBoot 1.3.6.1.4.1.1369.6.1.2.0.3
A node has booted up
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeShutdown 1.3.6.1.4.1.1369.6.1.2.0.4
A node is shutting down
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeUserLogin 1.3.6.1.4.1.1369.6.1.2.0.5
A user has started a login session
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeFailedUserLogin 1.3.6.1.4.1.1369.6.1.2.0.8
Failed user login
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeUserLogout 1.3.6.1.4.1.1369.6.1.2.0.9
A user has finished session
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeTestFailure 1.3.6.1.4.1.1369.6.1.2.0.6
NodeTest has failed
Status: current Access: read-only
NOTIFICATION-TYPE    

nodeHwmon 1.3.6.1.4.1.1369.6.1.2.0.7
Hardware monitoring system has detected problems
Status: current Access: read-only
NOTIFICATION-TYPE    

netNodeGroups 1.3.6.1.4.1.1369.6.1.3.1
OBJECT IDENTIFIER    

netNodeCompliances 1.3.6.1.4.1.1369.6.1.3.2
OBJECT IDENTIFIER    

nodeCompliance1 1.3.6.1.4.1.1369.6.1.3.2.1
The compliance statement for network nodes
Status: current Access: read-only
MODULE-COMPLIANCE    

nodeIdentificationGroup 1.3.6.1.4.1.1369.6.1.3.1.1
A collection of objects identifying the node in a cluster
Status: current Access: read-only
OBJECT-GROUP    

nodeStatusGroup 1.3.6.1.4.1.1369.6.1.3.1.2
A collection of objects giving information about the status of the node
Status: current Access: read-only
OBJECT-GROUP    

nodeLoginGroup 1.3.6.1.4.1.1369.6.1.3.1.3
A collection of objects giving information about logins into the node
Status: current Access: read-only
OBJECT-GROUP    

nodeTesterGroup 1.3.6.1.4.1.1369.6.1.3.1.4
A collection of objects giving information about the tests in the test subsystem of the node
Status: current Access: read-only
OBJECT-GROUP    

nodeHwmonGroup 1.3.6.1.4.1.1369.6.1.3.1.8
A collection of objects giving information about hardware monitoring events in the node
Status: current Access: read-only
OBJECT-GROUP    

nodeStatusNotificationsGroup 1.3.6.1.4.1.1369.6.1.3.1.5
A collection of notifications informing about changes in a node's status
Status: current Access: read-only
NOTIFICATION-GROUP    

nodeLoginNotificationsGroup 1.3.6.1.4.1.1369.6.1.3.1.6
A collection of notifications informing about user logins
Status: current Access: read-only
NOTIFICATION-GROUP    

nodeTesterNotificationsGroup 1.3.6.1.4.1.1369.6.1.3.1.7
A collection of notifications informing about test failures
Status: current Access: read-only
NOTIFICATION-GROUP    

nodeHwmonNotificationsGroup 1.3.6.1.4.1.1369.6.1.3.1.9
A collection of notifications informing about hardware monitoring issues
Status: current Access: read-only