TIARA-HSSI-MIB
File:
TIARA-HSSI-MIB.mib (13581 bytes)
Imported modules
Imported symbols
Defined Types
HssiConfigTableEntry |
|
SEQUENCE |
|
|
|
|
hssiIfIndex |
INTEGER |
|
|
hssiConfigClockRate |
Integer32 |
1000000..52000000 |
|
hssiConfigClockSource |
INTEGER |
|
|
hssiConfigTxClockSource |
INTEGER |
|
|
hssiConfigRxClockSource |
INTEGER |
|
|
hssiConfigMode |
INTEGER |
|
|
hssiConfigDataMode |
INTEGER |
|
|
hssiConfigCRC |
INTEGER |
|
|
hssiConfigProcessCtrlSignal |
INTEGER |
|
|
hssiDteLoopback |
TruthValue |
|
|
hssiDceLoopbackTest |
INTEGER |
|
HssiStatsTableEntry |
|
SEQUENCE |
|
|
|
|
hssiStatsAlarmStatus |
BITS |
|
|
hssiStatsFramesIn |
Counter32 |
|
|
hssiStatsFramesOut |
Counter32 |
|
|
hssiStatsOctetsIn |
Counter32 |
|
|
hssiStatsOctetsOut |
Counter32 |
|
|
hssiStatsCRCErrors |
Counter32 |
|
Defined Values
tiaraHssiMib |
1.3.6.1.4.1.3174.2.7.2 |
MIB definitions for Tiara HSSI modules. |
MODULE-IDENTITY |
|
|
|
hssiConfigTable |
1.3.6.1.4.1.3174.2.7.2.1 |
The HSSI interface configurable parameters are
listed in this table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
HssiConfigTableEntry |
|
hssiConfigTableEntry |
1.3.6.1.4.1.3174.2.7.2.1.1 |
HSSI table entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HssiConfigTableEntry |
|
|
hssiIfIndex |
1.3.6.1.4.1.3174.2.7.2.1.1.1 |
An integer value that is an index in the entries of the
ifTable (MIB-II) with a HSSI interface type. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
hssiConfigClockRate |
1.3.6.1.4.1.3174.2.7.2.1.1.2 |
Configures the clock rate (in Hertz) for the
HSSI interface. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1000000..52000000 |
|
hssiConfigClockSource |
1.3.6.1.4.1.3174.2.7.2.1.1.3 |
Configures the clock source for the HSSI
interface to either internal or line. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
internal(1), line(2) |
|
hssiConfigTxClockSource |
1.3.6.1.4.1.3174.2.7.2.1.1.4 |
Configures the transmit clock source for the HSSI
interface to either internal or terminal. This
variable is valid only for the HSSI interface on
the USSI card. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normalinternal(1), normalterminal(2), invertedinternal(3), invertedterminal(4) |
|
hssiConfigRxClockSource |
1.3.6.1.4.1.3174.2.7.2.1.1.5 |
Configures the receive clock source for the HSSI
interface to either internal or terminal. This
variable is valid only for the HSSI interface
on the USSI card |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normalinternal(1), normalterminal(2), invertedinternal(3), invertedterminal(4) |
|
hssiConfigMode |
1.3.6.1.4.1.3174.2.7.2.1.1.6 |
Configures the mode for the HSSI to either DCE
or DTE. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
dce(1), dte(2) |
|
hssiConfigDataMode |
1.3.6.1.4.1.3174.2.7.2.1.1.7 |
Configures the data mode for the HSSI interface.
This variable is valid only for the HSSI
interface on the USSI card. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), inverted(2) |
|
hssiConfigCRC |
1.3.6.1.4.1.3174.2.7.2.1.1.8 |
Configures the cyclic redundancy check for the
HSSI interface to either 16 or 32 bits. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
crc16(1), crc32(2) |
|
hssiConfigProcessCtrlSignal |
1.3.6.1.4.1.3174.2.7.2.1.1.9 |
Configures the processing of control signals
(CA/TA) for the HSSI interface. This variable
is valid only for the HSSI interface on the
USSI card. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ignore(1), process(2) |
|
hssiDteLoopback |
1.3.6.1.4.1.3174.2.7.2.1.1.10 |
Configures the local DTE for loopback operation:
TRUE : request local DTE to go into line loopback
FALSE : request local DTE to abandon line loopback
These commands are valid only if the HSSI adaptor
is in DCE mode and connected to a local DTE. Since
the local DTE has a greater loopback priority
than the local DCE, a loopback request initiated
by the DCE will be ignored if the DTE simultaneously
requests the DCE to loopback. Similarly, the DTE
will abort a loopback already initiated by the DCE
when the DTE requests the DCE to loopback. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
hssiDceLoopbackTest |
1.3.6.1.4.1.3174.2.7.2.1.1.11 |
Configures the local/remote DCE for loopback
operation. Three DCE loopback modes are available:
line, cable, and remote. Use noTest to abandon any
of the DCE loopbacks. If the DCE is already in any
one of the loopback modes, then noTest must be issued
to abort the current test before initiating another
loopback request. These commands are valid only if
the HSSI adaptor is in DTE mode and it connected
to a DCE. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noTest(1), line(2), cable(3), remote(4) |
|
hssiStatsTable |
1.3.6.1.4.1.3174.2.7.2.3 |
The HSSI interface status parameters are listed in
this table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
HssiStatsTableEntry |
|
hssiStatsTableEntry |
1.3.6.1.4.1.3174.2.7.2.3.1 |
HSSI Statistics table entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HssiStatsTableEntry |
|
|
hssiStatsAlarmStatus |
1.3.6.1.4.1.3174.2.7.2.3.1.1 |
Specifies the status of the HSSI alarm. If
the particular bit is set, then it indicates
that the alarm is in ON state. Alarm bits
are mode dependent; they are interpreted as
follows:
hssi-alarms-CA - CA not received from DCE
(HSSI is DTE)
hssi-alarms-ST - HSSI adaptor driving ST
(HSSI is DCE)
hssi-alarms-TM - TM received from DCE (HSSI
is DTE)
hssi-alarms-LC - HSSI adaptor detects LC
(HSSI is DTE)
hssi-alarms-LC - HSSI adaptor driving LC
(HSSI is DCE)
hssi-alarms-TA - TA not received from DTE
(HSSI is DCE)
hssi-alarms-LALB - HSSI adaptor detects LA
and/or LB (HSSI is DCE)
hssi-alarms-LALB - HSSI adaptor driving LA
and/or LB (HSSI is DTE)
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
BITS |
hssi-no-alarms(0), hssi-alarms-CA(1), hssi-alarms-ST(2), hssi-alarms-TM(3), hssi-alarms-LC(4), hssi-alarms-TA(5), hssi-alarms-LALB(6) |
|
hssiStatsFramesIn |
1.3.6.1.4.1.3174.2.7.2.3.1.2 |
Specifies the number of incoming frames. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
hssiStatsFramesOut |
1.3.6.1.4.1.3174.2.7.2.3.1.3 |
Specifies the number of outgoing frames. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
hssiStatsOctetsIn |
1.3.6.1.4.1.3174.2.7.2.3.1.4 |
Specifies the number of incoming octets. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
hssiStatsOctetsOut |
1.3.6.1.4.1.3174.2.7.2.3.1.5 |
Specifies the number of outgoing octets. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
hssiStatsCRCErrors |
1.3.6.1.4.1.3174.2.7.2.3.1.6 |
Specifies the number of CRC errors that have been
identified. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
hssiTraps |
1.3.6.1.4.1.3174.2.7.2.2 |
OBJECT IDENTIFIER |
|
|
|
hssiAlarmType |
1.3.6.1.4.1.3174.2.7.2.2.1.1 |
Specifies the type of alarm generated by the agent
for the HSSI interface. Alarms are mode dependent;
they are interpreted as follows:
hssi-alarms-CA - CA not received from DCE
(HSSI is DTE)
hssi-alarms-ST - HSSI adaptor driving ST
(HSSI is DCE)
hssi-alarms-TM - TM received from DCE (HSSI
is DTE)
hssi-alarms-LC - HSSI adaptor detects LC
(HSSI is DTE)
hssi-alarms-LC - HSSI adaptor driving LC
(HSSI is DCE)
hssi-alarms-TA - TA not received from DTE
(HSSI is DCE)
hssi-alarms-LALB - HSSI adaptor detects LA
and/or LB (HSSI is DCE)
hssi-alarms-LALB - HSSI adaptor driving LA
and/or LB (HSSI is DTE)
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hssi-alarm-CA(1), hssi-alarm-ST(2), hssi-alarm-TM(3), hssi-alarm-LC(4), hssi-alarm-TA(5), hssi-alarm-LALB(6) |
|