TIMETRA-OPEN-FLOW-MIB

File: TIMETRA-OPEN-FLOW-MIB.mib (50599 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
INET-ADDRESS-MIB TIMETRA-GLOBAL-MIB TIMETRA-TC-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Unsigned32 Counter64 MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP TEXTUAL-CONVENTION
RowStatus TimeStamp TruthValue
DisplayString InetAddress InetAddressType
InetPortNumber timetraSRMIBModules tmnxSRObjs
tmnxSRNotifyPrefix tmnxSRConfs TNamedItem
TmnxAdminState TmnxOperState TmnxPortID
TLNamedItemOrEmpty TmnxEnabledDisabled

Defined Types

TmnxOFDatapathIdentifier  
64-bit Organizationally Unique Identifier. The lower 48-bits are open-flow switch MAC address and the upper 16-bits are implementation dependent.
TEXTUAL-CONVENTION    
  OCTET STRING Size(8)  

TmnxOFPktType  
The value of TmnxOFPktType specifies the type of packet exchanged between an open-flow switch and the controller.
TEXTUAL-CONVENTION    
  INTEGER hello(1), error(2), echoRequest(3), echoReply(4), experimenter(5), featureRequest(6), featureReply(7), getConfigRequest(8), getConfigReply(9), setConfig(10), packetIn(11), flowRemoved(12), portStatus(13), packetOut(14), flowMod(15), groupMod(16), portMod(17), tableMod(18), multipartRequest(19), multipartReply(20), barrierRequest(21), barrierReply(22), getQueueConfigRequest(23), getQueueConfigReply(24), roleRequest(25), roleReply(26), getAsyncRequest(27), getAsyncReply(28), setAsync(29), meterMod(30)  

TmnxOFAsyncFltrPacketIn  
The value of TmnxOFAsyncFltrPacketIn specifies the asynchronous filter bitmap for message type 'packet-in'.
TEXTUAL-CONVENTION    
  BITS tableMiss(0), applyAction(1), invalidTTL(2)  

TmnxOFAsyncFltrPortStatus  
The value of TmnxOFAsyncFltrPortStatus specifies the asynchronous filter bitmap for message type 'port-status'.
TEXTUAL-CONVENTION    
  BITS portAdd(0), portDelete(1), portModify(2)  

TmnxOFAsyncFltrFlowRemoved  
The value of TmnxOFAsyncFltrFlowRemoved specifies the asynchronous filter bitmap for message type 'flow-removed'.
TEXTUAL-CONVENTION    
  BITS idleTimeOut(0), hardTimeOut(1), flowModDelete(2), groupDelete(3)  

TmnxOFSwitchEntry  
SEQUENCE    
  tmnxOFSwitchName TNamedItem
  tmnxOFSwitchRowStatus RowStatus
  tmnxOFSwitchLastChanged TimeStamp
  tmnxOFSwitchEchoInterval Unsigned32
  tmnxOFSwitchEchoMultiple Unsigned32
  tmnxOFSwitchLogicalPortStatus BITS
  tmnxOFSwitchAdminState TmnxAdminState
  tmnxOFSwitchDescription DisplayString
  tmnxOFSwitchDataPathID TmnxOFDatapathIdentifier
  tmnxOFSwitchFeaturesBufferSize Unsigned32
  tmnxOFSwitchFeaturesNumTables Unsigned32
  tmnxOFSwitchFeaturesCapability BITS
  tmnxOFSwitchAuxChannelEnabled TruthValue

TmnxOFControllerEntry  
SEQUENCE    
  tmnxOFControllerAddressType InetAddressType
  tmnxOFControllerAddress InetAddress
  tmnxOFControllerTCPPort InetPortNumber
  tmnxOFControllerRowStatus RowStatus
  tmnxOFControllerLastChanged TimeStamp
  tmnxOFControllerRole INTEGER
  tmnxOFControllerGenID Counter64

TmnxOFFlowTableEntry  
SEQUENCE    
  tmnxOFFlowTableId Unsigned32
  tmnxOFFlowTableRowStatus RowStatus
  tmnxOFFlowTableLastChanged TimeStamp
  tmnxOFFlowTableMaxSize Unsigned32
  tmnxOFFlowTableNoMatchAction INTEGER
  tmnxOFFlowTableNumEntries Unsigned32
  tmnxOFFlowTableOperStatus TmnxOperState
  tmnxOFFlowTableSwitchDefCookie TmnxEnabledDisabled

TmnxOFChannelInfoEntry  
SEQUENCE    
  tmnxOFChannelID Unsigned32
  tmnxOFChannelVersion Unsigned32
  tmnxOFChannelType INTEGER
  tmnxOFChannelOperStatus TmnxOperState
  tmnxOFChannelOperFlags BITS
  tmnxOFChannelEchoTimeExpiry Unsigned32
  tmnxOFChannelHoldTimeExpiry Unsigned32
  tmnxOFChannelConnRetryExpiry Unsigned32
  tmnxOFChannelConnUpTime Unsigned32
  tmnxOFChannelMEAsyncFltrPacketIn TmnxOFAsyncFltrPacketIn
  tmnxOFChannelSlAsyncFltrPacketIn TmnxOFAsyncFltrPacketIn
  tmnxOFChannelMEAsyncFltrPortSts TmnxOFAsyncFltrPortStatus
  tmnxOFChannelSlAsyncFltrPortSts TmnxOFAsyncFltrPortStatus
  tmnxOFChannelMEAsyncFltrFlowRem TmnxOFAsyncFltrFlowRemoved
  tmnxOFChannelSlAsyncFltrFlowRem TmnxOFAsyncFltrFlowRemoved
  tmnxOFChannelAuxiliaryID Unsigned32
  tmnxOFChannelSrcAddressType InetAddressType
  tmnxOFChannelSrcAddress InetAddress
  tmnxOFChannelSrcPort InetPortNumber

TmnxOFChannelStatsEntry  
SEQUENCE    
  tmnxOFChannelPacketType TmnxOFPktType
  tmnxOFChannelPacketTx Counter64
  tmnxOFChannelPacketRx Counter64
  tmnxOFChannelPacketErr Counter64

TmnxOFPortStatsEntry  
SEQUENCE    
  tmnxOFPortID TmnxPortID
  tmnxOFPortName TLNamedItemOrEmpty
  tmnxOFPortType INTEGER
  tmnxOFPortTxPackets Counter64
  tmnxOFPortTxBytes Counter64

Defined Values

timetraOpenFlowMIBModule 1.3.6.1.4.1.6527.1.1.3.93
This document is the SNMP MIB module for the Nokia SROS implementation of open-flow. Copyright 2003-2016 Nokia. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Nokia's proprietary intellectual property. Nokia retains all title and ownership in the Specification, including any revisions. Nokia grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Nokia products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Nokia makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
MODULE-IDENTITY    

tmnxOpenFlow 1.3.6.1.4.1.6527.3.1.2.93
OBJECT IDENTIFIER    

tmnxOpenFlowObjs 1.3.6.1.4.1.6527.3.1.2.93.1
OBJECT IDENTIFIER    

tmnxOpenFlowNotificationObjs 1.3.6.1.4.1.6527.3.1.2.93.2
OBJECT IDENTIFIER    

tmnxOpenFlowNotifyPrefix 1.3.6.1.4.1.6527.3.1.3.93
OBJECT IDENTIFIER    

tmnxOpenFlowNotification 1.3.6.1.4.1.6527.3.1.3.93.0
OBJECT IDENTIFIER    

tmnxOpenFlowConformance 1.3.6.1.4.1.6527.3.1.1.93
OBJECT IDENTIFIER    

tmnxOpenFlowCompliances 1.3.6.1.4.1.6527.3.1.1.93.1
OBJECT IDENTIFIER    

tmnxOpenFlowGroups 1.3.6.1.4.1.6527.3.1.1.93.2
OBJECT IDENTIFIER    

tmnxOpenFlowNotifGroups 1.3.6.1.4.1.6527.3.1.1.93.3
OBJECT IDENTIFIER    

tmnxOFSwitchTableLastChanged 1.3.6.1.4.1.6527.3.1.2.93.1.1
The value of tmnxOFSwitchTableLastChanged indicates the sysUpTime at the time of the last modification of an entry in the tmnxOFSwitchTable.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

tmnxOFSwitchTable 1.3.6.1.4.1.6527.3.1.2.93.1.2
The tmnxOFSwitchTable contains objects to configure an open-flow switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TmnxOFSwitchEntry

tmnxOFSwitchEntry 1.3.6.1.4.1.6527.3.1.2.93.1.2.1
The value of tmnxOFSwitchEntry represents an open-flow switch configuration information. Entries are created and deleted by the user.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxOFSwitchEntry  

tmnxOFSwitchName 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.1
The value of tmnxOFSwitchName specifies the name of this open-flow switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  TNamedItem  

tmnxOFSwitchRowStatus 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.2
The value of tmnxOFSwitchRowStatus controls the creation and deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

tmnxOFSwitchLastChanged 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.3
The value of tmnxOFSwitchLastChanged indicates the sysUpTime at the time of the most recent change to this open-flow switch.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

tmnxOFSwitchEchoInterval 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.4
The value of tmnxOFSwitchEchoInterval specifies the time interval between two consecutive open-flow echo request transmissions for a given open-flow session.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 1..3600  

tmnxOFSwitchEchoMultiple 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.5
The value of tmnxOFSwitchEchoMultiple specifies the number of consecutive open-flow echo reply message lost to terminate the open-flow session. Once the open-flow channel is terminated, retry to open the session is initiated using non-configurable retry timer sequence.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 3..100  

tmnxOFSwitchLogicalPortStatus 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.6
The value of tmnxOFSwitchLogicalPortStatus specifies a bit mask for the type of reporting for logical open-flow ports (interfaces with open-flow enabled) to the controller. Setting the 'rsvpTe(0)' bit reports status/statistics for all RSVP-TE LSP's present in the system that are used as output port in flow-table to redirect all RSVP LSP's. Setting the 'mplsTp(1)' bit reports status/statistics for all MPLS-TP LSP's present in the system that are used as output port in flow-table to redirect MPLS-TP LSP's. By default, all bits are cleared.
Status: current Access: read-create
OBJECT-TYPE    
  BITS rsvpTe(0), mplsTp(1)  

tmnxOFSwitchAdminState 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.7
The value of tmnxOFSwitchAdminState specifies the desired administrative state of an open-flow switch instance.
Status: current Access: read-create
OBJECT-TYPE    
  TmnxAdminState  

tmnxOFSwitchDescription 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.8
The value of tmnxOFSwitchDescription specifies the user provided description for this open-flow switch instance.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..255)  

tmnxOFSwitchDataPathID 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.9
The value of tmnxOFSwitchDataPathID indicates a 64-bit identifier for this open-flow switch instance. The lower 48-bits are its MAC address and the upper 16-bits are implementation dependent.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOFDatapathIdentifier  

tmnxOFSwitchFeaturesBufferSize 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.10
The value of tmnxOFSwitchFeaturesBufferSize indicates the maximum number of packets this open-flow switch instance can buffer while sending the packets to the controller when the message type is 'packet-in'.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFSwitchFeaturesNumTables 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.11
The value of tmnxOFSwitchFeaturesNumTables indicates the number of open-flow tables associated with this switch instance.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFSwitchFeaturesCapability 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.12
The value of tmnxOFSwitchFeaturesCapability indicates the bitmap of capabilities supported by the datapath associated with this open-flow switch instance.
Status: current Access: read-only
OBJECT-TYPE    
  BITS flowStats(0), tableStats(1), portStats(2)  

tmnxOFSwitchAuxChannelEnabled 1.3.6.1.4.1.6527.3.1.2.93.1.2.1.13
The value of tmnxOFSwitchAuxChannelEnabled specifies whether the auxiliary connection (channel) exits between the controller and the open-flow switch. When the value of tmnxOFSwitchAuxChannelEnabled is set to 'true (1)', the auxiliary statistics channel is established for sending statistics information. Additionally, the auxiliary packet-in channel is established for sending packet-in information, if the value of tmnxOFFlowTableNoMatchAction is set to 'packetIn (3). If the packet-in auxiliary channel could not be established, the auxiliary statistics channel will be used is present. If the auxiliary channel could not be established, main channel will be used. When the value of tmnxOFSwitchAuxChannelEnabled is set to 'false (2)', the auxiliary channel won't established and main channel will be used.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

tmnxOFControllerTableLastChanged 1.3.6.1.4.1.6527.3.1.2.93.1.3
The value of tmnxOFControllerTableLastChanged indicates the sysUpTime at the time of the last modification of an entry in the tmnxOFControllerTable.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

tmnxOFControllerTable 1.3.6.1.4.1.6527.3.1.2.93.1.4
The tmnxOFControllerTable contains objects to configure an open-flow controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TmnxOFControllerEntry

tmnxOFControllerEntry 1.3.6.1.4.1.6527.3.1.2.93.1.4.1
The value of tmnxOFControllerEntry represents an open-flow controller configuration information that is connected to open-flow switch specified by tmnxOFSwitchName. Entries are created and deleted by the user.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxOFControllerEntry  

tmnxOFControllerAddressType 1.3.6.1.4.1.6527.3.1.2.93.1.4.1.1
The value of tmnxOFControllerAddressType specifies the address type of the controller IP address specified by tmnxOFControllerAddress.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddressType  

tmnxOFControllerAddress 1.3.6.1.4.1.6527.3.1.2.93.1.4.1.2
The value of tmnxOFControllerAddress specifies IP address of the controller connected to open-flow switch specified by tmnxOFSwitchName.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddress Size(4|16)  

tmnxOFControllerTCPPort 1.3.6.1.4.1.6527.3.1.2.93.1.4.1.3
The value of tmnxOFControllerTCPPort specifies the TCP port number of the controller connected to open-flow switch specified by tmnxOFSwitchName.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetPortNumber 1..65535  

tmnxOFControllerRowStatus 1.3.6.1.4.1.6527.3.1.2.93.1.4.1.4
The value of tmnxOFControllerRowStatus controls the creation and deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

tmnxOFControllerLastChanged 1.3.6.1.4.1.6527.3.1.2.93.1.4.1.5
The value of tmnxOFControllerLastChanged indicates the sysUpTime at the time of the most recent change to this controller.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

tmnxOFControllerRole 1.3.6.1.4.1.6527.3.1.2.93.1.4.1.6
The value of tmnxOFControllerRole indicates the role of the controller connected to an open-flow switch specified by tmnxOFSwitchName.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noChange(0), equal(1), master(2), slave(3)  

tmnxOFControllerGenID 1.3.6.1.4.1.6527.3.1.2.93.1.4.1.7
The value of tmnxOFControllerGenID indicates 64-bit generation identifier used for checking of stale messages when the value of tmnxOFControllerRole is 'master (2)' or 'slave (3)'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tmnxOFFlowTableTableLastChanged 1.3.6.1.4.1.6527.3.1.2.93.1.5
The value of tmnxOFFlowTableTableLastChanged indicates the sysUpTime at the time of the last modification of an entry in the tmnxOFFlowTableTable.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

tmnxOFFlowTableTable 1.3.6.1.4.1.6527.3.1.2.93.1.6
The tmnxOFFlowTableTable contains objects to configure a flow-table per open-flow switch instance.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TmnxOFFlowTableEntry

tmnxOFFlowTableEntry 1.3.6.1.4.1.6527.3.1.2.93.1.6.1
The value of tmnxOFFlowTableEntry represents a flow-table specific to to an open-flow switch instance. The current release does not support multiple multiple flow-table, therefore there will not be more than one row entry in this table; attempts to create additional rows in this table will be denied.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxOFFlowTableEntry  

tmnxOFFlowTableId 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.1
The value of tmnxOFFlowTableId specifies the unique identifier for the flow table per open-flow switch instance. Current release supports one flow-table per open-flow switch instance with the value of tmnxOFFlowTableId equal to 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

tmnxOFFlowTableRowStatus 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.2
The value of tmnxOFFlowTableRowStatus controls the creation and deletion of rows in the table. The row entry for tmnxOFFlowTableId equal 0 cannot be deleted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

tmnxOFFlowTableLastChanged 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.3
The value of tmnxOFFlowTableLastChanged indicates the sysUpTime at the time of the most recent change to this flow-table.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

tmnxOFFlowTableMaxSize 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.4
The value of tmnxOFFlowTableMaxSize specifies the maximum number of entries that the flow table can have. The maximum size cannot be changed if any entries are present in the flow-table.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 1..262144  

tmnxOFFlowTableNoMatchAction 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.5
The value of tmnxOFFlowTableNoMatchAction specifies the action to be performed when no match is found in the flow table. When the value of tmnxOFFlowTableNoMatchAction is set to 'drop (1)', packets are dropped if no match is found in flow table. When the value of tmnxOFFlowTableNoMatchAction is set to 'fall-through (2), evaluating is continued based on filter policy. When the value of tmnxOFFlowTableNoMatchAction is set to 'packetIn (3)', packets are forwarded to the controller if no match is found in flow table.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER drop(1), fallThrough(2), packetIn(3)  

tmnxOFFlowTableNumEntries 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.6
The value of tmnxOFFlowTableNumEntries indicates the total number of open-flow entries currently present in the flow-table.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFFlowTableOperStatus 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.7
The value of tmnxOFFlowTableOperStatus indicates the operational status of the flow table for a given open-flow switch instance.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOperState  

tmnxOFFlowTableSwitchDefCookie 1.3.6.1.4.1.6527.3.1.2.93.1.6.1.8
The value of tmnxOFFlowTableSwitchDefCookie specifies whether to enable switch-defined cookie encoding or use standard cookie encoding for this flow-table. When the value of tmnxOFFlowTableSwitchDefCookie is set to 'disabled (2)', open-flow controller uses standard cookie encoding. When the value of tmnxOFFlowTableSwitchDefCookie is set to 'enabled (1)', open-flow controller encodes cookie with special information detailed below: 64 60 59 32 31 0 +-------------+-------------------------+-----------------------+ | cookie-type | switch-defined-cookie | standard-flow-cookie | +-------------+-------------------------+-----------------------+ Cookie Name Cookie Type Cookie Value Cookie Usage (Bits 63..60) (Bits 59..32) ----------- ------------- ------------ ------------------------- grt 0 0 0 0 0 use this cookie value to program flowtable rules to be used in GRT instance system 1 0 0 0 0 use this cookie value to program flowtable rules to be used in system filters service 1 1 0 0 service-id for use this cookie value to 'vpls' or program flowtable rules 'vprn' to be used in 'vpls' or services 'vprn' service-types All other values for the cookie are reserved.
Status: current Access: read-create
OBJECT-TYPE    
  TmnxEnabledDisabled  

tmnxOFChannelInfoTable 1.3.6.1.4.1.6527.3.1.2.93.1.7
The tmnxOFChannelInfoTable contains channel information used for exchanging messages between open-flow switch and controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TmnxOFChannelInfoEntry

tmnxOFChannelInfoEntry 1.3.6.1.4.1.6527.3.1.2.93.1.7.1
The value of tmnxOFChannelInfoEntry specifies channel information associated an open-flow switch and the controller used for exchanging of messages.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxOFChannelInfoEntry  

tmnxOFChannelID 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.1
The value of tmnxOFChannelID specifies the unique channel identifier between an open-flow switch and the controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

tmnxOFChannelVersion 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.2
The value of tmnxOFChannelVersion indicates the open-flow version negotiated between an open-flow switch and the controller.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFChannelType 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.3
The value of tmnxOFChannelType indicates the type of connection established between an open-flow switch and the controller.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), auxiliary(2)  

tmnxOFChannelOperStatus 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.4
The value of tmnxOFChannelOperStatus indicates the operational status of the channel established between an open-flow switch and the controller.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOperState  

tmnxOFChannelOperFlags 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.5
The value of tmnxOFChannelOperFlags indicates various conditions that affects the operational status of the channel established between an open-flow switch and the controller.
Status: current Access: read-only
OBJECT-TYPE    
  BITS socketStateDisable(0), socketStateListen(1), socketStateConnecting(2), socketStateEstablished(3), helloReceived(4), helloTransmitted(5), handshake(6)  

tmnxOFChannelEchoTimeExpiry 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.6
The value of tmnxOFChannelEchoTimeExpiry indicates the time remaining before an open-flow switch sends another echo-request message to the controller for an established open-flow channel.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFChannelHoldTimeExpiry 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.7
The value of tmnxOFChannelHoldTimeExpiry indicates the time remaining for keeping an open-flow session alive since receiving an echo-response message. When the timer expires, the open-flow session is terminated.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFChannelConnRetryExpiry 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.8
The value of tmnxOFChannelConnRetryExpiry indicates the time remaining after which an open-flow switch will retry to establish an open-flow session with the controller if not successful initially.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFChannelConnUpTime 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.9
The value of tmnxOFChannelConnUpTime indicates how long an open-flow session has been up. If the session is down, zero value is returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFChannelMEAsyncFltrPacketIn 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.10
The value of tmnxOFChannelMEAsyncFltrPacketIn indicates whether the controller when in 'master' or 'equal' role will receive asynchronous messages for message type 'packet-in'.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOFAsyncFltrPacketIn  

tmnxOFChannelSlAsyncFltrPacketIn 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.11
The value of tmnxOFChannelSlAsyncFltrPacketIn indicates whether the controller when in 'slave' role will receive asynchronous messages for message type 'packet-in'.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOFAsyncFltrPacketIn  

tmnxOFChannelMEAsyncFltrPortSts 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.12
The value of tmnxOFChannelMEAsyncFltrPortSts indicates whether the controller when in 'master' or 'equal' role will receive asynchronous messages for message type 'port-status'.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOFAsyncFltrPortStatus  

tmnxOFChannelSlAsyncFltrPortSts 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.13
The value of tmnxOFChannelSlAsyncFltrPortSts indicates whether the controller when in 'slave' role will receive asynchronous messages for message type 'port-status'.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOFAsyncFltrPortStatus  

tmnxOFChannelMEAsyncFltrFlowRem 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.14
The value of tmnxOFChannelMEAsyncFltrFlowRem indicates whether the controller when in 'master' or 'equal' role will receive asynchronous messages for message type 'flow-removed'.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOFAsyncFltrFlowRemoved  

tmnxOFChannelSlAsyncFltrFlowRem 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.15
The value of tmnxOFChannelSlAsyncFltrFlowRem indicates whether the controller when in 'slave' role will receive asynchronous messages for message type 'flow-removed'.
Status: current Access: read-only
OBJECT-TYPE    
  TmnxOFAsyncFltrFlowRemoved  

tmnxOFChannelAuxiliaryID 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.16
The value of tmnxOFChannelAuxiliaryID indicates the auxiliary channel identifier.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tmnxOFChannelSrcAddressType 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.17
The value of tmnxOFChannelSrcAddressType indicates the address type for the source IP address specified by tmnxOFChannelSrcAddress.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressType  

tmnxOFChannelSrcAddress 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.18
The value of tmnxOFChannelSrcAddress indicates the source IP address used for connecting to the controller.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddress Size(0|4|16)  

tmnxOFChannelSrcPort 1.3.6.1.4.1.6527.3.1.2.93.1.7.1.19
The value of tmnxOFChannelSrcPort indicates the source port number used for connecting to the controller.
Status: current Access: read-only
OBJECT-TYPE    
  InetPortNumber  

tmnxOFChannelStatsTable 1.3.6.1.4.1.6527.3.1.2.93.1.8
The tmnxOFChannelStatsTable contains channel statistics information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TmnxOFChannelStatsEntry

tmnxOFChannelStatsEntry 1.3.6.1.4.1.6527.3.1.2.93.1.8.1
The value of tmnxOFChannelStatsEntry specifies statistics information for the various packets exchanged between an open-flow switch and the controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxOFChannelStatsEntry  

tmnxOFChannelPacketType 1.3.6.1.4.1.6527.3.1.2.93.1.8.1.1
The value of tmnxOFChannelPacketType specifies the packet type exchanged between an open-flow switch and the controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxOFPktType  

tmnxOFChannelPacketTx 1.3.6.1.4.1.6527.3.1.2.93.1.8.1.2
The value of tmnxOFChannelPacketTx indicates the total number of packets transmitted by an open-flow switch specified by tmnxOFSwitchName.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tmnxOFChannelPacketRx 1.3.6.1.4.1.6527.3.1.2.93.1.8.1.3
The value of tmnxOFChannelPacketRx indicates the total number of packets received by an open-flow switch specified by tmnxOFSwitchName.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tmnxOFChannelPacketErr 1.3.6.1.4.1.6527.3.1.2.93.1.8.1.4
The value of tmnxOFChannelPacketErr indicates the total number of error packets exchanged by open-flow switch specified by tmnxOFSwitchName with the controller.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tmnxOFPortStatsTable 1.3.6.1.4.1.6527.3.1.2.93.1.9
The tmnxOFPortStatsTable contains port statistics information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TmnxOFPortStatsEntry

tmnxOFPortStatsEntry 1.3.6.1.4.1.6527.3.1.2.93.1.9.1
The value of tmnxOFPortStatsEntry specifies statistics information related to port associated with an open-flow switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxOFPortStatsEntry  

tmnxOFPortID 1.3.6.1.4.1.6527.3.1.2.93.1.9.1.1
The value of tmnxOFPortID specifies the port identifier for uniquely identifying a port within an open-flow switch instance specified by tmnxOFSwitchName.
Status: current Access: not-accessible
OBJECT-TYPE    
  TmnxPortID  

tmnxOFPortName 1.3.6.1.4.1.6527.3.1.2.93.1.9.1.2
The value of tmnxOFPortName indicates the textual name of the interface. The value of this object should be the name of the interface as assigned by the open-flow switch.
Status: current Access: read-only
OBJECT-TYPE    
  TLNamedItemOrEmpty  

tmnxOFPortType 1.3.6.1.4.1.6527.3.1.2.93.1.9.1.3
The value of tmnxOFPortType indicates the port-type for port identifier specified by tmnxOFPortID. openFlowPhysicalPort (1) - corresponds to hardware interface of an open-flow switch. openFlowLogicalPort (2) - corresponds to higher level abstractions defined by an open-flow switch (e.g. link aggregation groups, tunnels, loopback interfaces). openFlowReservedPort (3) - specifies generic forwarding actions such as sending to the controller, flooding, or forwarding using non open-flow methods, such as 'normal' switch processing.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER openFlowPhysicalPort(0), openFlowLogicalPort(1), openFlowReservedPort(2)  

tmnxOFPortTxPackets 1.3.6.1.4.1.6527.3.1.2.93.1.9.1.4
The value of tmnxOFPortTxPackets indicates the total number of packets transmitted by this open-flow port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tmnxOFPortTxBytes 1.3.6.1.4.1.6527.3.1.2.93.1.9.1.5
The value of tmnxOFPortTxBytes indicates the total number of bytes transmitted by this open-flow port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tmnxOFNotifyDescription 1.3.6.1.4.1.6527.3.1.2.93.2.1
The object tmnxOFNotifyDescription is a printable character string.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

tmnxOFFlowEntryInsertFailed 1.3.6.1.4.1.6527.3.1.3.93.0.1
[CAUSE] The tmnxOFFlowEntryInsertFailed notification is generated when a flow-entry could not be inserted into an open-flow table. [EFFECT] The flow-entry won't be available in the flow-table. If inserting of a default flow-entry failed, then the value of tmnxOFFlowTableOperStatus is set to 'outOfService (3)'. [RECOVERY] In order to insert the failed flow-entry into flow-table is to change the admin state of an open-flow switch instance to 'outOfService (3)' and then back to 'inService (1)' and try inserting the flow-entry again.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

tmnxOpenFlowComplianceV12v0 1.3.6.1.4.1.6527.3.1.1.93.1.1
The compliance statement for management of Open Flow features on Nokia SROS series systems release 12.0.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

tmnxOpenFlowComplianceV13v0 1.3.6.1.4.1.6527.3.1.1.93.1.2
The compliance statement for management of Open Flow features on Nokia SROS series systems release 13.0.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

tmnxOpenFlowComplianceV14v0 1.3.6.1.4.1.6527.3.1.1.93.1.3
The compliance statement for management of Open Flow features on Nokia SROS series systems release 14.0.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

tmnxOpenFlowV12v0Groups 1.3.6.1.4.1.6527.3.1.1.93.2.1
OBJECT IDENTIFIER    

tmnxOpenFlowV13v0Groups 1.3.6.1.4.1.6527.3.1.1.93.2.2
OBJECT IDENTIFIER    

tmnxOpenFlowV14v0Groups 1.3.6.1.4.1.6527.3.1.1.93.2.3
OBJECT IDENTIFIER    

tmnxOpenFlowConfigGroup 1.3.6.1.4.1.6527.3.1.1.93.2.1.1
The group of objects supporting open-flow configuration on Nokia SROS series systems release 12.0.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

tmnxOpenFlowNotifyObjsGroup 1.3.6.1.4.1.6527.3.1.1.93.2.1.2
The group of notification objects supporting open-flow notifications on Nokia SROS series systems 12.0 release.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

tmnxOpenFlowNotificationGroup 1.3.6.1.4.1.6527.3.1.1.93.2.1.3
The group of notifications reporting open-flow state changes on on Nokia SROS series systems 12.0 release.
Status: current Access: accessible-for-notify
NOTIFICATION-GROUP    

tmnxOpenFlowV13v0Group 1.3.6.1.4.1.6527.3.1.1.93.2.2.1
The group of objects supporting open-flow configuration on Nokia SROS series systems release 13.0.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

tmnxOpenFlowAuxChannelGroup 1.3.6.1.4.1.6527.3.1.1.93.2.3.1
The group of objects supporting open-flow configuration on Nokia SROS series systems release 14.0.
Status: current Access: accessible-for-notify
OBJECT-GROUP