TM62-MIB
File:
TM62-MIB.mib (38083 bytes)
Imported modules
Imported symbols
Defined Types
Hundredths |
|
np. przeksztalc 1234 na 12.34 |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
0..65535 |
|
LogEntry |
|
SEQUENCE |
|
|
|
|
logIndex |
INTEGER |
0..1999 |
|
logEventDescription |
DisplayString |
Size(0..23) |
EsEntryES15T |
|
SEQUENCE |
|
|
|
|
esIndexES15T |
INTEGER |
0..16 |
|
esOpisEventDescriptionES15T |
DisplayString |
Size(0..22) |
EsEntryES15R |
|
SEQUENCE |
|
|
|
|
esIndexES15R |
INTEGER |
0..16 |
|
esEventDescriptionES15R |
DisplayString |
Size(0..22) |
EsEntrySES15T |
|
SEQUENCE |
|
|
|
|
esIndexSES15T |
INTEGER |
0..16 |
|
esEventDescriptionSES15T |
DisplayString |
Size(0..22) |
EsEntrySES15R |
|
SEQUENCE |
|
|
|
|
esIndexSES15R |
INTEGER |
0..16 |
|
esEventDescriptionSES15R |
DisplayString |
Size(0..22) |
EsEntryES24T |
|
SEQUENCE |
|
|
|
|
esIndexES24T |
INTEGER |
0..1 |
|
esEventDescriptionES24T |
DisplayString |
Size(0..24) |
EsEntryES24R |
|
SEQUENCE |
|
|
|
|
esIndexES24R |
INTEGER |
0..1 |
|
esEventDescriptionES24R |
DisplayString |
Size(0..24) |
EsEntrySES24T |
|
SEQUENCE |
|
|
|
|
esIndexSES24T |
INTEGER |
0..1 |
|
esEventDescriptionSES24T |
DisplayString |
Size(0..24) |
EsEntrySES24R |
|
SEQUENCE |
|
|
|
|
esIndexSES24R |
INTEGER |
0..1 |
|
esEventDescriptionSES24R |
DisplayString |
Size(0..24) |
Defined Values
lanex |
1.3.6.1.4.1.5746 |
OBJECT IDENTIFIER |
|
|
|
telecom |
1.3.6.1.4.1.5746.1 |
OBJECT IDENTIFIER |
|
|
|
main |
1.3.6.1.4.1.5746.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
status |
1.3.6.1.4.1.5746.1.1.3 |
OBJECT IDENTIFIER |
|
|
|
eventLog |
1.3.6.1.4.1.5746.1.1.4 |
OBJECT IDENTIFIER |
|
|
|
es |
1.3.6.1.4.1.5746.1.1.5 |
OBJECT IDENTIFIER |
|
|
|
test |
1.3.6.1.4.1.5746.1.1.6 |
OBJECT IDENTIFIER |
|
|
|
optiLine4 |
1.3.6.1.4.1.5746.1.1 |
Tok_String |
MODULE-IDENTITY |
|
|
|
mainDeviceName |
1.3.6.1.4.1.5746.1.1.1.1 |
Nazwa urzadzenia (tekst - 16 znakow) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
mainDeviceDescription |
1.3.6.1.4.1.5746.1.1.1.2 |
Tekstowy opis urzadzenia (tekst - 16 znakow) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
mainDeviceType |
1.3.6.1.4.1.5746.1.1.1.3 |
Typ urzadzenia:
44 - TM-44
49 - TM-60
60 - TM-60
61 - TM-61
62 - OptiLine 4 (TM-62)
63 - OptiLine 16 (TM-63) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
mainHardwareVersion |
1.3.6.1.4.1.5746.1.1.1.4 |
Wersja produkcyjna urzadzenia
(np.TM-62.x ,gdzie x-wersja produkcyjna |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
mainLNMPAddress |
1.3.6.1.4.1.5746.1.1.1.5 |
Adres urzdzenia wykorzystany w protokole LNMP dla LanWin |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mainDevicePhysicalNumber |
1.3.6.1.4.1.5746.1.1.1.6 |
Numer fabryczny urzadzenia |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
mainDeviceSoftwareVersion |
1.3.6.1.4.1.5746.1.1.1.7 |
Wersja kodu ukladu programowalnego
np. 101 oznacza wersje 1.01
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
mainSoftwareVersion |
1.3.6.1.4.1.5746.1.1.1.8 |
Wersja oprogramowania
np. wartosc 101 oznacza wersje 1.01 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
mainPasswordActivity |
1.3.6.1.4.1.5746.1.1.1.9 |
Aktywacja hasa dostepu do urzdzenia: 0 - haso nieaktywne 1- haso aktywne |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
mainPassword |
1.3.6.1.4.1.5746.1.1.1.10 |
Haslo dostepu do urzadzenia |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..8) |
|
mainDateTime |
1.3.6.1.4.1.5746.1.1.1.11 |
Data i czas systemowy |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
confLOES |
1.3.6.1.4.1.5746.1.1.2.1 |
Zalaczanie/blokowanie kanalow skladowych 1-4
Rejestr ZKS jest 8 bitowy i ustawienie poszczegolnych
bitow od bitu nr 0 do 3 na wartooeae 1 powoduje zalonczenie,
a ustawienie na 0 wylonczenie odpowiednio kanalu 1-4.
bit : 3 2 1 0
nazwa : ZKS4 ZKS3 ZKS2 ZKS1 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
confAlarmConfirm |
1.3.6.1.4.1.5746.1.1.2.3 |
Kasowanie (potwierdzanie) alarmu
1- kasowanie |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
confTransmitterType |
1.3.6.1.4.1.5746.1.1.2.4 |
Typ nadajnika bloku zbiorczego:
0-dioda laserowa,
1-dioda LED
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
confTransmitterStatus |
1.3.6.1.4.1.5746.1.1.2.5 |
Ustawienie nadajnika laserowego:
0-wylaczony/automatyka,
1-pelna moc,
2-obnizona moc |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
confProgMAXTemperature |
1.3.6.1.4.1.5746.1.1.2.6 |
Gorny dopuszczalny poziom temperatury w systemie
(wartooeae np. 2758 oznacza temperature 27.58 stopni C) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
confProgMINTemperature |
1.3.6.1.4.1.5746.1.1.2.7 |
Dolny dopuszczalny poziom temperatury w systemie
(wartooeae np. 2758 oznacza temperature 27.58 stopni C) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
confProgMAX5V |
1.3.6.1.4.1.5746.1.1.2.10 |
Gorny dopuszczalny poziom napiecia 5V
(wartooeae np. 527 oznacza napiecie 5.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
confProgMIN5V |
1.3.6.1.4.1.5746.1.1.2.11 |
Dolny dopuszczalny poziom napiecia 5V
(wartooeae np. 527 oznacza napiecie 5.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
confProgMAX12V |
1.3.6.1.4.1.5746.1.1.2.12 |
Gorny dopuszczalny poziom napiecia 12V
(wartooeae np. 1227 oznacza napiecie 12.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
confProgMIN12V |
1.3.6.1.4.1.5746.1.1.2.13 |
Dolny dopuszczalny poziom napiecia 12V
(wartooeae np. 1227 oznacza napiecie 12.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
confProgMAXM12V |
1.3.6.1.4.1.5746.1.1.2.14 |
Gorny dopuszczalny poziom napiecia -12V
(wartooeae np. 1227 oznacza napiecie -12.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
confProgMINM12V |
1.3.6.1.4.1.5746.1.1.2.15 |
Dolny dopuszczalny poziom napiecia -12V
(wartooeae np. 1227 oznacza napiecie -12.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
statLOES |
1.3.6.1.4.1.5746.1.1.3.1 |
Stan rejestru Sygnalow Skladowych 1-4
Zanik sygnau skadowego przychodzcego
do wejoecia (ZSSx=1 - zanik sygnau, ZSSx=0 - sygna obecny, gdzie: x - numer kanalu).
bit : 3 2 1 0
nazwa : ZSS4 ZSS3 ZSS2 ZSS1 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
statAISLM |
1.3.6.1.4.1.5746.1.1.3.2 |
Stan rejestru Sygnalow AIS Lokalnych 1-4
Odbior sygnau AIS przez urzdzenie lokalne
na wejoeciu (AISLx=1 - urzdzenie odbiera sygna AIS,
AISLx=0 - brak sygnau AIS, gdzie: x - numer kanalu).
bit : 3 2 1 0
nazwa : AISL4 AISL3 AISL2 AISL1 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
statAISRM |
1.3.6.1.4.1.5746.1.1.3.3 |
Stan rejestru Sygnalow AIS Zdalnych 1-4
Odbior sygnau AIS przez urzdzenie lokalne
na wejoeciu (AISZx=1 - urzdzenie odbiera sygna AIS,
AISZx=0 - brak sygnau AIS, gdzie: x - numer kanalu).
bit : 3 2 1 0
nazwa : AISZ4 AISZ3 AISZ2 AISZ1 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
statVIOL |
1.3.6.1.4.1.5746.1.1.3.4 |
Stan rejestru Blad Wiolacji Sygnalu Skladowego 1-4
(BWSSx=1 - jest blad na kanale x,
BWSSx=0 - brak bledu na kanale x, gdzie: x - numer kanalu).
bit : 3 2 1 0
nazwa : BWSS4 BWSS3 BWSS2 BWSS1 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
statBZSTAT |
1.3.6.1.4.1.5746.1.1.3.5 |
Stan rejestru Status Bloku Zbiorczego
BZSTAT jest rejestrem 8 bitowym. Znaczenie jego bitow:
bit 5: ALZUZ-Alarm Zwrotny Z Urzdzenia Zdalnego (ALZUZ=1 - urzdzenie otrzymao sygna alarmu zwrotnego, ALZUZ=0 - brak sygnau alarmu zwrotnego).
bit 4: 106K - Przekroczenie stopy 10-6 bedow kodowych w odebranym sygnale zbiorczym (E10_6=1 - nastpio przekroczenie, E10_6=0 - przekroczenie nie nastpio).
bit 3: 103K - Przekroczenie stopy 10-3 bedow kodowych w odebranym sygnale zbiorczym (E10_3=1 - nastpio przekroczenie, E10_3=0 - przekroczenie nie nastpio).
bit 2: USR - Utrata Synchronizacji Ramki
bit 1: ZMN - Zanik Mocy Nadajnika (0 moc poprawna, 1 moc niepoprawna)
bit 0: ZSO - Zanik Sygnau Optycznego na wejoeciu oewiatowodowym |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
statSUS |
1.3.6.1.4.1.5746.1.1.3.6 |
Stan rejestru Status Ukladu Sygnalizacji
Bity sygnalizacji alarmow:
bit 0: DALP - bit sygnalizacji alarmu pilnego lub zaniku alarmu po potwierdzeniu
bit 1: DPALP - bit sygnalizacji przypomnienia alarmu pilnego
bit 2: PALP - bit zaczenia przekaYnika alarmu pilnego
bit 3: DALN - bit sygnalizacji alarmu niepilnego lub zaniku alarmu po potwierdzeniu
bit 4: DPALN - bit sygnalizacji przypomnienia alarmu niepilnego
bit 5: PALN - bit zaczenia przekaYnika alarmu niepilnego |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
statKJT |
1.3.6.1.4.1.5746.1.1.3.7 |
Stan rejestru Kontrola Jakosci Transmisji
Bity rejestru:
bit 7: PSES24O - Wystpienie przekroczenia wartooeci progowej dla rejestru SES,24 godzinnego, dla kierunku odbiorczego
(PSES24O=1 - nastpio przekroczenie, PSES24O=0 - przekroczenie nie nastpio)
bit 6: PSES24N - Wstpienie przekroczenia wartooeci progowej dla rejestru SES, 24 godzinnego, dla kierunku nadawczego
(PSES24N=1 - nastpio przekroczenie, PSES24N=0 - przekroczenie nie nastpio)
bit 5: PES24O - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 24 godzinnego, dla kierunku odbiorczego
(PES24O=1 - nastpio przekroczenie, PES24O=0 - przekroczenie nie nastpio)
bit 4: PES24N - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 24 godzinnego, dla kierunku nadawczego
(PES24N=1 - nastpio przekroczenie, PES24N=0 - przekroczenie nie nastpio)
bit 3: PSES15O - Wystpienie przekroczenia wartooeci progowej dla rejestru SES, 15 minutowego, dla kierunku odbiorczego
(PSES15O=1 - nastpio przekroczenie, PSES15O=0 - przekroczenie nie nastpio)
bit 2: PSES15N - Wystpienie przekroczenia wartooeci progowej dla rejestru SES, 15 minutowego, dla kierunku nadawczego
(PSES15N=1 - nastpio przekroczenie, PSES15N=0 - przekroczenie nie nastpio)
bit 1: PES15O - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 15 minutowego, dla kierunku odbiorczego
(PES15O=1 - nastpio przekroczenie, PES15O=0 - przekroczenie nie nastpio)
bit 0: PES15N - Wystpienie przekroczenia wartooeci progowej dla rejestru ES, 15 minutowego, dla kierunku nadawczego
(PES15N=1 - nastpio przekroczenie, PES15N=0 - przekroczenie nie nastpio) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
statTemperature |
1.3.6.1.4.1.5746.1.1.3.8 |
Temperatura otoczenia systemu
(wartooeae np. 2758 oznacza temperature 27.58 stopni C) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Hundredths |
|
|
stat5VVoltage |
1.3.6.1.4.1.5746.1.1.3.10 |
Napiecie zasilania 5V
(wartooeae np. 527 oznacza napiecie 5.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
stat12VVoltage |
1.3.6.1.4.1.5746.1.1.3.11 |
Napiecie zasilania 12V
(wartooeae np. 1227 oznacza napiecie 12.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
statM12VVoltage |
1.3.6.1.4.1.5746.1.1.3.12 |
Napiecie zasilania -12V
(wartooeae np. 1227 oznacza napiecie -12.27 V) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
statExtremLevel |
1.3.6.1.4.1.5746.1.1.3.13 |
Stan napieae zasilajcych i temperatury otoczenia.
Poszczegolne bity oznaczaj przekroczenie wartooeci dopuszczalnej (progowej):
(1 - przekroczenie wartosci progowej, 0 - wrtosc ponizej ustawionego progu)
bit 1: - napiecia 5V
bit 2: - napiecia 12V
bit 3: - napiecia -12V
bit 7: - temperatury otoczenia |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
logIndexLastEvent |
1.3.6.1.4.1.5746.1.1.4.1 |
Indeks do ostatnio wpisanego zdarzenia w historii dziennika zdarzen
-1 oznacza pusty dziennik |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-1..1999 |
|
logErase |
1.3.6.1.4.1.5746.1.1.4.2 |
Kasowanie dziennika zdarzen ustawienie 1 - kasowanie |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
kasowanie(1) |
|
logTable |
1.3.6.1.4.1.5746.1.1.4.3 |
Tabela opisuje dziennik zdarzen |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
LogEntry |
|
logEntry |
1.3.6.1.4.1.5746.1.1.4.3.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LogEntry |
|
|
logIndex |
1.3.6.1.4.1.5746.1.1.4.3.1.1 |
Indeks zdarzenia |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1999 |
|
logEventDescription |
1.3.6.1.4.1.5746.1.1.4.3.1.2 |
Opis Zdarzenia:
YYYY/MM/DD HH:MM.SS ZZZ
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
SS - sekunda
ZZZ - identyfikator zdarzenia
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..23) |
|
esLastES15T |
1.3.6.1.4.1.5746.1.1.5.1 |
Indeks ostatniego zapisanego rejestru ES15N w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
esLastES15R |
1.3.6.1.4.1.5746.1.1.5.2 |
Indeks ostatniego zapisanego rejestru ES15O w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
esLastSES15T |
1.3.6.1.4.1.5746.1.1.5.3 |
Indeks ostatniego zapisanego rejestru SES15N w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
esLastSES15R |
1.3.6.1.4.1.5746.1.1.5.4 |
Indeks ostatniego zapisanego rejestru SES15O w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
esLastES24T |
1.3.6.1.4.1.5746.1.1.5.5 |
Indeks ostatniego zapisanego rejestru ES24N w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esLastES24R |
1.3.6.1.4.1.5746.1.1.5.6 |
Indeks ostatniego zapisanego rejestru ES24O w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esLastSES24T |
1.3.6.1.4.1.5746.1.1.5.7 |
Indeks ostatniego zapisanego rejestru SES24N w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esLastSES24R |
1.3.6.1.4.1.5746.1.1.5.8 |
Indeks ostatniego zapisanego rejestru SES24O w tablicy licznikow |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esErase |
1.3.6.1.4.1.5746.1.1.5.9 |
Kasowanie rejestrow Es/Ses ustawienie 1 - kasowanie |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
kasowanie(1) |
|
esESAlarm |
1.3.6.1.4.1.5746.1.1.5.10 |
Aktywacja alarmu przekroczenia wartooeci progowej ES lub SES
0 - nieaktywny
1 - aktywny |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esES15On |
1.3.6.1.4.1.5746.1.1.5.11 |
Wartosc progowa zalaczenia alarmu niepilnego w okresie 15 min. (0-900) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..900 |
|
esES15Off |
1.3.6.1.4.1.5746.1.1.5.12 |
Wartosc progowa wylaczenia alarmu niepilnego w okresie 15 min. (0-900) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..900 |
|
esSES15On |
1.3.6.1.4.1.5746.1.1.5.13 |
Wartosc progowa zalaczenia alarmu pilnego w okresie 15 min. (0-900) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..900 |
|
esSES15Off |
1.3.6.1.4.1.5746.1.1.5.14 |
Wartosc progowa wylaczenia alarmu pilnego w okresie 15 min. (0-900) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..900 |
|
esES24On |
1.3.6.1.4.1.5746.1.1.5.15 |
Wartosc progowa zalaczenia alarmu niepilnego w okresie 24 h. (0-86400) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..86400 |
|
esES24Off |
1.3.6.1.4.1.5746.1.1.5.16 |
Wartosc progowa wylaczenia alarmu niepilnego w okresie 24 h. (0-86400) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..86400 |
|
esSES24On |
1.3.6.1.4.1.5746.1.1.5.17 |
Wartosc progowa zalaczenia alarmu pilnego w okresie 24 h. (0-86400) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..86400 |
|
esSES24Off |
1.3.6.1.4.1.5746.1.1.5.18 |
Wartosc progowa wylaczenia alarmu pilnego w okresie 24 h. (0-86400) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..86400 |
|
esESSESHour |
1.3.6.1.4.1.5746.1.1.5.19 |
Godzina rozpoczecia zliczania w rejestrach ES i SES |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..23 |
|
esESSESMinute |
1.3.6.1.4.1.5746.1.1.5.20 |
Minuta rozpoczecia zliczania w rejestrach ES i SES |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..59 |
|
esTableES15T |
1.3.6.1.4.1.5746.1.1.5.21 |
Tabela opisuje zapis licznikow ES15N |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntryES15T |
|
esEntryES15T |
1.3.6.1.4.1.5746.1.1.5.21.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntryES15T |
|
|
esIndexES15T |
1.3.6.1.4.1.5746.1.1.5.21.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..16 |
|
esEventDescriptionES15T |
1.3.6.1.4.1.5746.1.1.5.21.1.2 |
Opis:
YYYY/MM/DD HH:MM LLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLL - licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..22) |
|
esTableES15R |
1.3.6.1.4.1.5746.1.1.5.22 |
Tabela opisuje zapis licznika ES15O |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntryES15R |
|
esEntryES15R |
1.3.6.1.4.1.5746.1.1.5.22.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntryES15R |
|
|
esIndexES15R |
1.3.6.1.4.1.5746.1.1.5.22.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..16 |
|
esEventDescriptionES15R |
1.3.6.1.4.1.5746.1.1.5.22.1.2 |
Opis:
YYYY/MM/DD HH:MM LLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLL - licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..22) |
|
esTableSES15T |
1.3.6.1.4.1.5746.1.1.5.23 |
Tabela opisuje zapis licznika SES15N |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntrySES15T |
|
esEntrySES15T |
1.3.6.1.4.1.5746.1.1.5.23.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntrySES15T |
|
|
esIndexSES15T |
1.3.6.1.4.1.5746.1.1.5.23.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..16 |
|
esEventDescriptionSES15T |
1.3.6.1.4.1.5746.1.1.5.23.1.2 |
Opis:
YYYY/MM/DD HH:MM LLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLL - licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..22) |
|
esTableSES15R |
1.3.6.1.4.1.5746.1.1.5.24 |
Tabela opisuje zapis licznika SES15O |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntrySES15R |
|
esEntrySES15R |
1.3.6.1.4.1.5746.1.1.5.24.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntrySES15R |
|
|
esIndexSES15R |
1.3.6.1.4.1.5746.1.1.5.24.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..16 |
|
esEventDescriptionSES15R |
1.3.6.1.4.1.5746.1.1.5.24.1.2 |
Opis:
YYYY/MM/DD HH:MM LLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLL - licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..22) |
|
esTableES24T |
1.3.6.1.4.1.5746.1.1.5.25 |
Tabela opisuje zapis licznika ES24N |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntryES24T |
|
esEntryES24T |
1.3.6.1.4.1.5746.1.1.5.25.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntryES24T |
|
|
esIndexES24T |
1.3.6.1.4.1.5746.1.1.5.25.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esEventDescriptionES24T |
1.3.6.1.4.1.5746.1.1.5.25.1.2 |
Opis:
YYYY/MM/DD HH:MM LLLLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLLLL- licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..24) |
|
esTableES24R |
1.3.6.1.4.1.5746.1.1.5.26 |
Tabela opisuje zapis licznika ES24O |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntryES24R |
|
esEntryES24R |
1.3.6.1.4.1.5746.1.1.5.26.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntryES24R |
|
|
esIndexES24R |
1.3.6.1.4.1.5746.1.1.5.26.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esEventDescriptionES24R |
1.3.6.1.4.1.5746.1.1.5.26.1.2 |
Opis:
YYYY/MM/DD HH:MM LLLLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLLLL- licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..24) |
|
esTableSES24T |
1.3.6.1.4.1.5746.1.1.5.27 |
Tabela opisuje zapis licznika SES24N |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntrySES24T |
|
esEntrySES24T |
1.3.6.1.4.1.5746.1.1.5.27.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntrySES24T |
|
|
esIndexSES24T |
1.3.6.1.4.1.5746.1.1.5.27.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..11 |
|
esEventDescriptionES24T |
1.3.6.1.4.1.5746.1.1.5.27.1.2 |
Opis:
YYYY/MM/DD HH:MM LLLLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLLLL- licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..24) |
|
esTableSES24R |
1.3.6.1.4.1.5746.1.1.5.28 |
Tabela opisuje zapis licznika SES24O |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsEntrySES24R |
|
esEntrySES24R |
1.3.6.1.4.1.5746.1.1.5.28.1 |
Tok_String |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsEntrySES24R |
|
|
esIndexSES24R |
1.3.6.1.4.1.5746.1.1.5.28.1.1 |
Indeks |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
esEventDescriptionSES24R |
1.3.6.1.4.1.5746.1.1.5.28.1.2 |
Opis:
YYYY/MM/DD HH:MM LLLLL A
YYYY - rok
MM - miesiac
DD - dzien
HH - godzina
MM - minuta
LLLLL- licznik sekund z bledami
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..24) |
|
testTributaryChannLoopType1 |
1.3.6.1.4.1.5746.1.1.6.1 |
Zalaczenie petli kanalu
skladowego 1 - 4 do interfejsu.
(ALx = 1 zaczenie petli, ALx = 0 wyczene petli na kanale x)
bit : 3 2 1 0
nazwa : AL4 AL3 AL2 AL1 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
testGeneratorDetector |
1.3.6.1.4.1.5746.1.1.6.5 |
numer generatora/detektora
wykorzystywanego do testu
1..4 - generator w kierunku kanalu skladowego (E1) 1..4 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..4 |
|
testGCT |
1.3.6.1.4.1.5746.1.1.6.6 |
Sterowanie zaczaniem/wyczaniem generatorow testowych wybranych kanaow skladowych/zbiorczych:
1 - generator zaczony
0 - generator wyczony |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
testTime |
1.3.6.1.4.1.5746.1.1.6.7 |
Deklarowany czas trwania testu w sekundach. Maks. 24 godziny |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..86400 |
|
testSyncTime |
1.3.6.1.4.1.5746.1.1.6.8 |
czas pomiaru gdy jest synchronizacja |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..86400 |
|
testNoSyncTime |
1.3.6.1.4.1.5746.1.1.6.9 |
czas pomiaru gdy brak synchronizacji |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..86400 |
|
testErrorsPerSec |
1.3.6.1.4.1.5746.1.1.6.10 |
Biezaca liczba bledow w cyklu sekundowym |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
testBER |
1.3.6.1.4.1.5746.1.1.6.12 |
Stopa bledow w formacie:
P.Pe-LL (notacja naukowa)
przyklad: 2.3e-09 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..7) |
|
testSyncYesNo |
1.3.6.1.4.1.5746.1.1.6.16 |
Flaga synchronizacji (1 - oznacza detekcje cigu testowego) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
brakSynchronizacja(0), jestSynchronizacja(1) |
|
testStatus |
1.3.6.1.4.1.5746.1.1.6.17 |
status wykonywania testu
0 - OFF - test wyczony
1 - ON - test zaczony
2 - RUN - test trwa
3 - READY - gotowooeae do rozpoczecia testu
4 - WAIT_ON - oczekiwanie na zaczenie testu
5 - WAIT_OFF - oczekiwanie na wyczenie testu
6 - WAIT - oczekiwanie |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..6 |
|
obEventIdn |
1.3.6.1.4.1.5746.1.1.7.1.1 |
Nr zdarzenia |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
trapOptiLine4ALPActive |
1.3.6.1.4.1.5746.1.1.7.0.1 |
Aktywny Alarm pilny |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
trapOptiLine4ALNActive |
1.3.6.1.4.1.5746.1.1.7.0.2 |
Aktywny Alarm niepilny |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
trapOptiLine4LogIdn |
1.3.6.1.4.1.5746.1.1.7.0.3 |
Wystapienie zdarzenia w urzadzeniu:
1.Zapis do lokalnego dziennika zdarzen
2.Przekazanie identyfikatora zdarzenia w trapie
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
trapOptiLine4Es |
1.3.6.1.4.1.5746.1.1.7.0.4 |
Zmiana w licznikach es/ses |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
trapOptiLine4confn |
1.3.6.1.4.1.5746.1.1.7.0.5 |
Zapis do zmiennej z grupy knfiguracja,
n - identyfikator elementu, ktory zostal zmodyfikowany |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
trapOptiLine4ALPInactive |
1.3.6.1.4.1.5746.1.1.7.0.6 |
Nieaktywny Alarm pilny |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
trapOptiLine4ALNInactive |
1.3.6.1.4.1.5746.1.1.7.0.7 |
Nieaktywny Alarm niepilny |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|