TY1250I-MIB

File: TY1250I-MIB.mib (46656 bytes)

Imported modules

SNMPv2-TC RFC1155-SMI RFC-1215
RFC-1212

Imported symbols

DisplayString Counter TimeTicks
enterprises IpAddress TRAP-TYPE
OBJECT-TYPE

Defined Types

Ty1250CfgMaintEntry  
SEQUENCE    
  ty1250CfgMaintIndex INTEGER 1..2
  ty1250CfgMaintMode INTEGER
  ty1250CfgMaintBaud INTEGER
  ty1250CfgMaintDataBits INTEGER
  ty1250CfgMaintStopBits INTEGER
  ty1250CfgMaintParity INTEGER
  ty1250CfgMaintFlowCtrl INTEGER

Defined Values


dsucsu 1.3.6.1.4.1.466.1
OBJECT IDENTIFIER    

tyview 1.3.6.1.4.1.466.2
OBJECT IDENTIFIER    

ty1250 1.3.6.1.4.1.466.3
OBJECT IDENTIFIER    

ty1250SysTable 1.3.6.1.4.1.466.3.1
OBJECT IDENTIFIER    

ty1250SysType 1.3.6.1.4.1.466.3.1.1
A textual description of the system model identifier. for example: TYLINK1250
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

ty1250SysSoftRev 1.3.6.1.4.1.466.3.1.2
Displays the Software Revision installed in this node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

ty1250SysHardRev 1.3.6.1.4.1.466.3.1.3
Displays the Hardware Revision of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

ty1250SysNumNetInstalled 1.3.6.1.4.1.466.3.1.4
The number of Network (DDS) ports that are installed. There is 1 on the 1250.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

ty1250SysNumDteInstalled 1.3.6.1.4.1.466.3.1.5
The number of channels (DTE) that are installed. There is 1 on the 1250.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

ty1250SysNumMaintInstalled 1.3.6.1.4.1.466.3.1.6
The number of Maintenance ports that are installed. There are 2 on the 1250.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

ty1250SysName 1.3.6.1.4.1.466.3.1.7
The user supplied name of the node. This object does not affect operation, but may be useful for network management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

ty1250CfgAppTable 1.3.6.1.4.1.466.3.2
OBJECT IDENTIFIER    

ty1250CfgAppClockSource 1.3.6.1.4.1.466.3.2.2
Default timing, or clock, source. There must be only one source on a DDS line. Node should always be network (2) timed on a point-to-network application. Line Driver applications need one node as internal (1), one as network (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), network(2)  

ty1250CfgAppCircuitId 1.3.6.1.4.1.466.3.2.3
Circuit identifier provided by the service provider.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

ty1250CfgNetTable 1.3.6.1.4.1.466.3.3
OBJECT IDENTIFIER    

ty1250CfgNetType 1.3.6.1.4.1.466.3.3.11
Indicates type of service purchased on the attached network line (DDS or SW56). Valid selections are dedicated (1) and switch56 (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dedicated(1), switch56(2)  

ty1250CfgNetGlareType 1.3.6.1.4.1.466.3.3.4
In switched applications, defines who wins when there are simultanious incomming and outgoing calls. If in doubt, select external-glare (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external-glare(1), internal-glare(2)  

ty1250CfgNetEchoCan 1.3.6.1.4.1.466.3.3.5
In switched applications, some carriers, such as Sprint, require you to disable-echo-cancellors (2) for data apps on most lines. Calls take longer to come up when disabling is done; use ignore-echo-cancellers (1) on clear channel lines.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ignore-echo-cancellers(1), disable-echo-cancellers(2)  

ty1250CfgNetAnsMode 1.3.6.1.4.1.466.3.3.6
In switched applications, allows for manual-answer (1) or automatic-answer (2) of inbound calls. Calls may be answered in manual mode via vt100, DTR, or the front panel button if so configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manual-answer(1), automatic-answer(2)  

ty1250CfgNetDialTimeout 1.3.6.1.4.1.466.3.3.7
In switched applications, time in seconds to wait for far end to answer before giving up, and possibly redialing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

ty1250CfgNetNumRedial 1.3.6.1.4.1.466.3.3.8
In switched applications, number of times to redial if the call fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

ty1250CfgNetRedialDelay 1.3.6.1.4.1.466.3.3.9
In switched applications, delay in seconds between redial attempts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

ty1250CfgNetDefNum2Dial 1.3.6.1.4.1.466.3.3.10
In switched applications, default phone number to dial. Numbers and dashes are allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

ty1250CfgNetBPVThresholding 1.3.6.1.4.1.466.3.3.12
Allows the user to turn on and off the BPV thresholding function. Valid values are thresholding_at_10E-4 (1) and disable-thresholding (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresholding-at-10E-4(1), disable-thresholding(2)  

ty1250CfgDteTable 1.3.6.1.4.1.466.3.4
OBJECT IDENTIFIER    

ty1250CfgDteType 1.3.6.1.4.1.466.3.4.1
The Dte channel type identifies the electrical specification of the interface. Read-only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v35(2), rs449(3)  

ty1250CfgDteClockInvert 1.3.6.1.4.1.466.3.4.5
Clock Inversion, invert-dte-clock (2), can be used to solve out of phase timing problems on DTE link. normal-dte-clock (1) can be used in most cases.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal-dte-clock(1), invert-dte-clock(2)  

ty1250CfgDteTiming 1.3.6.1.4.1.466.3.4.6
The DTE channel Timing mode. Use loop2-timing (2) when in doubt.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loop1-timing(1), loop2-timing(2)  

ty1250CfgDialTable 1.3.6.1.4.1.466.3.5
OBJECT IDENTIFIER    

ty1250CfgDialButton 1.3.6.1.4.1.466.3.5.1
In switched applications, Enables/Disables the button on front of unit. This button can used to manual answer an incomming call, or dial out the default number. The valid values are enable-button (1) and disable-button (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-button(1), disable-button(2)  

ty1250CfgDialDtr 1.3.6.1.4.1.466.3.5.2
In switched applications, Enables/Disables dialing on DTR signal transition. Valid values enable-dtr (1) and disable-dtr (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-dtr(1), disable-dtr(2)  

ty1250CfgDialRtsDisc 1.3.6.1.4.1.466.3.5.3
In switched applications, Enables/Disables disconnecting on RTS signal transition. Valid values are enable-rts (1) and disable-rts (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-rts(1), disable-rts(2)  

ty1250CfgDialRi 1.3.6.1.4.1.466.3.5.4
In switched applications, Enables/Disables incoming call notification to DTE via RI signal. Valid values are enable-ri (1) and disable-ri (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-ri(1), disable-ri(2)  

ty1250CfgMaintTable 1.3.6.1.4.1.466.3.6
The Maintenance Port Configuration table contains parameters for the Maintenance ports on the 1250. The Terminal Port is Index=1; SLIP port is 2
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty1250CfgMaintEntry

ty1250CfgMaintEntry 1.3.6.1.4.1.466.3.6.1
Maintenance Port Configuration Object
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty1250CfgMaintEntry  

ty1250CfgMaintIndex 1.3.6.1.4.1.466.3.6.1.1
The Maintenance port under consideration. On the 1250, the Terminal Port is Index=1; SLIP port is 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

ty1250CfgMaintMode 1.3.6.1.4.1.466.3.6.1.2
The Mode for this Maintenance Port. Values include ascii-vt100 (4), slip (7), and cslip (8).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ascii-vt100(4), slip(7), cslip(8)  

ty1250CfgMaintBaud 1.3.6.1.4.1.466.3.6.1.3
Baud rate for this Maintenance port. Values are baud-2400 (2), baud-9600 (4), baud-19200 (5).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud-2400(2), baud-9600(4), baud-19200(5)  

ty1250CfgMaintDataBits 1.3.6.1.4.1.466.3.6.1.4
Databits for this Maintenance port. Values are databits-7 (1) and databits-8 (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER databits-7(1), databits-8(2)  

ty1250CfgMaintStopBits 1.3.6.1.4.1.466.3.6.1.5
Number of Stopbits for this Maintenance port. Values are stopbits-1 (1), stopbits-1-5 (2), and stopbits-2 (3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stopbits-1(1), stopbits-1-5(2), stopbits-2(3)  

ty1250CfgMaintParity 1.3.6.1.4.1.466.3.6.1.6
Parity for this Maintenance port. Values are no-parity (1), odd-parity (2), even-parity (3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-parity(1), odd-parity(2), even-parity(3)  

ty1250CfgMaintFlowCtrl 1.3.6.1.4.1.466.3.6.1.7
Flow Control for this Maintenance port. Values are no-flow-control (1), software-flow-control (2), and hardware-flow-control (3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-flow-control(1), software-flow-control(2), hardware-flow-control(3)  

ty1250CfgSlipTable 1.3.6.1.4.1.466.3.8
OBJECT IDENTIFIER    

ty1250CfgSlipMyIP 1.3.6.1.4.1.466.3.8.1
The IP address for this node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty1250CfgSlipPeerIP 1.3.6.1.4.1.466.3.8.2
The IP address for other end of slip connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty1250CfgSlipMask 1.3.6.1.4.1.466.3.8.3
The IP Network Mask (eg 255.255.255.0) for the SLIP link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty1250CfgSlipMaxMTU 1.3.6.1.4.1.466.3.8.4
The Maximum Transmission Unit is the size of the largest IP packet supported. This value should be set to the lowest value supported by any equipment in the transmission path. A size of 1006 (including header) is suggested.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1024  

ty1250CfgSnmpTable 1.3.6.1.4.1.466.3.14
OBJECT IDENTIFIER    

ty1250CfgSnmpManagerIP 1.3.6.1.4.1.466.3.14.1
The IP address for the SNMP manager to receive this node's TRAPs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty1250CfgTelnetTable 1.3.6.1.4.1.466.3.17
OBJECT IDENTIFIER    

ty1250CfgTelnetEnable 1.3.6.1.4.1.466.3.17.1
Enables/Disables the telnet feature. Valid values are enable-telnet (1) and disable-telnet (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-telnet(1), disable-telnet(2)  

ty1250CfgTelnetAutoLogOut 1.3.6.1.4.1.466.3.17.2
Enables/Disables the telnet auto-logout, logging out the user after a certain length of idle time. Valid values are autologout-at-15-minutes (1) and disable-autologout (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autologout-at-15-minutes(1), disable-autologout(2)  

ty1250CallTable 1.3.6.1.4.1.466.3.9
OBJECT IDENTIFIER    

ty1250CallState 1.3.6.1.4.1.466.3.9.4
Call-related actions: a: Connect (initiate a call), b: Disconnect (terminate a call) c: Answer (answer an incoming call).
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER connect(1), disconnect(2), answer(3)  

ty1250CallStatus 1.3.6.1.4.1.466.3.9.1
The call status is shown here.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), idle(2), dialing(3), busy(4), waiting-for-redial(5), redialing(6), active(7), incoming-call(8), line-in-maintenance(253), line-down(254)  

ty1250CallNumber 1.3.6.1.4.1.466.3.9.2
The last phone number dialed out.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

ty1250CallUpTime 1.3.6.1.4.1.466.3.9.3
Number of seconds the call has been up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

ty1250DiagUnitTable 1.3.6.1.4.1.466.3.10
OBJECT IDENTIFIER    

ty1250DiagUnitLocLoop 1.3.6.1.4.1.466.3.10.1
Enables the operator to control and examine the UNIT local loopback. This loopback occurs on all network ports transmit and receive logic. The unit will transmit DTE data out to the network as normal, and will also loop DTE data back to the DTE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-loopback-mode(1), disable-loopback-mode(2)  

ty1250DiagUnitReset 1.3.6.1.4.1.466.3.10.2
Enables the operator to remotely reset the unit. Using this command will cause the unit to terminate all its connections and drop data.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset-unit(1)  

ty1250DiagNetTable 1.3.6.1.4.1.466.3.11
OBJECT IDENTIFIER    

ty1250DiagNetLineStatus 1.3.6.1.4.1.466.3.11.1
The Current status of the physical interface. Your network carrier can send Out-of-Service or Maintenance Mode codes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER in-sync(1), out-of-service(2), out-of-frame(3), bpv-threshold-failure(4), loss-of-signal(5), simplex-current-loopback(6)  

ty1250DiagNetLclLpbk 1.3.6.1.4.1.466.3.11.2
Enables the operator to control and examine the network local loopback. This loopback occurs on the net side of the local transmit and receive logic. The unit continues to receive data from the network and also loops received data back to the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-loopback-mode(1), disable-loopback-mode(2)  

ty1250DiagNetRmtLpbk 1.3.6.1.4.1.466.3.11.3
Enables the operator to examine (ONLY) the status of network loopbacks placed by external equipment, such as your local CO. These loopbacks will loop received network data back out the network, disconnecting the DTE completely.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-loop-from-remote(1), simplex-current-loop(2), non-latching-loop(3)  

ty1250DiagDteTable 1.3.6.1.4.1.466.3.12
OBJECT IDENTIFIER    

ty1250DiagDteSigRTS 1.3.6.1.4.1.466.3.12.1
The Dte Channel RTS signal. Values are rts-signal-on (1) and rts-signal-off (2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rts-signal-on(1), rts-signal-off(2)  

ty1250DiagDteSigDTR 1.3.6.1.4.1.466.3.12.2
The Dte Channel DTR signal. Values are dtr-signal-on (1) and dtr-signal-off (2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dtr-signal-on(1), dtr-signal-off(2)  

ty1250DiagDteLclLpbk 1.3.6.1.4.1.466.3.12.5
This selection displays the status or controls the Local DTE Channel Loopback for the selected channel. This is will loop DTE data back towards the DTE interface in addition to passing it on to the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-loopback-mode(1), disable-loopback-mode(2)  

ty1250DiagDteV54Lpbk 1.3.6.1.4.1.466.3.12.6
This selection displays the status of the DTE Channel V.54 Loopback for the channel. This loopback is initiated by the remote node, causing this node to loop data back to the remote node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER loopback-enable(1), loopback-disable(2)  

ty1250DiagDteRmtV54Lpbk 1.3.6.1.4.1.466.3.12.13
This selection controls the DTE Channel V.54 Remote Loopback. Transmit-code-enable (3) will cause the node to transmit a V.54 code to the remote node which will then loop received data back to this node. transmit-code-disable (4) will transmit the disable code.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER transmit-code-enable(3), transmit-code-disable(4)  

ty1250DiagDteBerState 1.3.6.1.4.1.466.3.12.7
BERT test related actions: a: Starts a BERT test on a channel, b: Stops a BERT test on a channel, c: Inject Errors while the BERT test is running, d: Clears BERT test errors.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER start-bert-test(1), stop-bert-test(2), inject-error-bert-test(3), clear-error-bert-test(4)  

ty1250DiagDteBerStatus 1.3.6.1.4.1.466.3.12.8
Displays the current BERT test sync status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bert-off(1), bert-out-of-sync(2), bert-in-sync(3)  

ty1250DiagDteBerErrors 1.3.6.1.4.1.466.3.12.9
Displays the number of errors detected in Bert Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ty1250DiagDteBerErrSec 1.3.6.1.4.1.466.3.12.10
Displays the number of seconds containing errors in BERT Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ty1250DiagDteBerTimeElaps 1.3.6.1.4.1.466.3.12.11
Elapsed time since BERT test was started or cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

ty1250DiagDteBerResyncs 1.3.6.1.4.1.466.3.12.12
Displays the number of times BERT test has synched up on the pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ty1250StatsDteTable 1.3.6.1.4.1.466.3.15
OBJECT IDENTIFIER    

ty1250StatsDteTxByteCount 1.3.6.1.4.1.466.3.15.1
The statistic counting the number of bytes transmitted on the DTE channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ty1250StatsDteRxByteCount 1.3.6.1.4.1.466.3.15.2
The statistic counting the number of bytes received on the DTE channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ty1250StatsDteClearStats 1.3.6.1.4.1.466.3.15.3
Allows the user to zero out all the statistics in the DTE statistics table.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER clear-statistics(1)  

ty1250StatsNetTable 1.3.6.1.4.1.466.3.16
OBJECT IDENTIFIER    

ty1250StatsNetLoopLength 1.3.6.1.4.1.466.3.16.1
The statistic that estimates line attentuation on the network channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ty1250StatsNetBpvCount 1.3.6.1.4.1.466.3.16.2
The statistic counting the number of BPV errors on the network channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ty1250StatsNetTxByteCount 1.3.6.1.4.1.466.3.16.3
The statistic counting the number of bytes transmitted on the network channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ty1250StatsNetRxByteCount 1.3.6.1.4.1.466.3.16.4
The statistic counting the number of bytes received on the network channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ty1250StatsNetClearStats 1.3.6.1.4.1.466.3.16.5
Allows the user to zero out all the statistics in the network statistics table.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER clear-statistics(1)  

ty1250AlarmType 1.3.6.1.4.1.466.3.13
The type of alarms that are generated on the node
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER line-failure(1), line-in-service(2), connected(3), connect-failure(4), incoming-call(5), disconnected(6), bad-config-in-set(7), config-local-update(8), bpv-threshold-exceeded(9), bpv-threshold-acceptable(10), local-unit-loopback-enabled(11), local-unit-loopback-disabled(12), local-network-loopback-enabled(13), local-network-loopback-disabled(14), remote-network-simplex-loopback-enabled(15), remote-network-simplex-loopback-disabled(16), remote-network-non-latching-loopback-enabled(17), remote-network-non-latching-loopback-disabled(18), v54-loop-up-initiated(19), v54-loop-down-completed(20), v54-loopback-enabled-by-remote(21), v54-loopback-disabled-by-remote(22), bert-test-pattern-initiated(23), bert-test-pattern-completed(24), local-dte-loopback-enabled(25), local-dte-loopback-disabled(26), local-unit-loopback-failure(27), local-network-loopback-failure(28), bert-test-pattern-failure(29), local-dte-loopback-failure(30), v54-loopback-failure(31)  

ty1250Trap 0
A ty1250Trap trap signifies that the sending node had its `ty1250AlarmType` variable modified.
TRAP-TYPE    

ty1250LineFailureTrap 1
The line has failed.
TRAP-TYPE    

ty1250LineInServiceTrap 2
The line is back in service.
TRAP-TYPE    

ty1250ConnectedTrap 3
The 1250 unit is connected.
TRAP-TYPE    

ty1250ConnectFailureTrap 4
The attempted connection failed.
TRAP-TYPE    

ty1250IncomingCallTrap 5
Incoming call.
TRAP-TYPE    

ty1250DisconnectedTrap 6
Disconnected.
TRAP-TYPE    

ty1250BadConfigTrap 7
The configuration specified in the SET command was bad. SET failed.
TRAP-TYPE    

ty1250LocalConfigTrap 8
The configuration has been changed by a means other than SNMP.
TRAP-TYPE    

ty1250BPVThresholdExceededTrap 9
BPV threshold exceeded.
TRAP-TYPE    

ty1250BPVThresholdAcceptableTrap 10
BPV threshold acceptable.
TRAP-TYPE    

ty1250LocalUnitLoopbackEnabledTrap 11
Local unit loopback enabled.
TRAP-TYPE    

ty1250LocalUnitLoopbackDisabledTrap 12
Local unit loopback disabled.
TRAP-TYPE    

ty1250LocalNetLoopbackEnabledTrap 13
Local network loopback enabled.
TRAP-TYPE    

ty1250LocalNetLoopbackDisabledTrap 14
Local network loopback disabled.
TRAP-TYPE    

ty1250SimplexCurrentLoopbackEnabledTrap 15
Simplex current loopback enabled.
TRAP-TYPE    

ty1250SimplexCurrentLoopbackDisabledTrap 16
Simplex current loopback disabled.
TRAP-TYPE    

ty1250NonLatchingLoopbackEnabledTrap 17
Nonlatching loopback enabled.
TRAP-TYPE    

ty1250NonLatchingLoopbackDisabledTrap 18
Nonlatching loopback disabled.
TRAP-TYPE    

ty1250V54LoopUpInitiatedTrap 19
Starting to loop up a V54 loopback on the remote unit.
TRAP-TYPE    

ty1250V54LoopDownCompletedTrap 20
Completed the loop down of a V54 loopback on the remote unit.
TRAP-TYPE    

ty1250V54LoopbackEnabledTrap 21
V54 loopback enabled by remote unit.
TRAP-TYPE    

ty1250V54LoopbackDisabledTrap 22
V54 loopback disabled by remote unit.
TRAP-TYPE    

ty1250BertInitiatedTrap 23
BERT test pattern initiated.
TRAP-TYPE    

ty1250BertCompletedTrap 24
BERT test pattern completed.
TRAP-TYPE    

ty1250LocalDteLoopbackEnabledTrap 25
Local DTE loopback enabled.
TRAP-TYPE    

ty1250LocalDteLoopbackDisabledTrap 26
Local DTE loopback disabled.
TRAP-TYPE    

ty1250LocalUnitLoopbackFailedTrap 27
Unable to do a local unit loopback.
TRAP-TYPE    

ty1250LocalNetLoopbackFailedTrap 28
Unable to do a local network loopback.
TRAP-TYPE    

ty1250BertFailedTrap 29
Unable to do a BERT.
TRAP-TYPE    

ty1250LocalDteLoopbackFailedTrap 30
Unable to do a local DTE loopback.
TRAP-TYPE    

ty1250V54LoopbackFailedTrap 31
Unable to do a V54 loopback.
TRAP-TYPE