USR-SS7-MIB

File: USR-SS7-MIB.mib (20623 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC USR-DEFINITIONS-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
IpAddress Integer32 DateAndTime
common

Defined Types

UsrSS7SlotEntry  
SEQUENCE    
  usrSS7Slot Integer32
  usrSS7SlotOwner INTEGER
  usrSS7SlotType INTEGER
  usrSS7SlotConnectionStatus Integer32
  usrSS7SlotTrace INTEGER
  usrSS7SlotConnectToSlot Integer32
  usrSS7SlotDisconnectToSlot Integer32
  usrSS7ENFASLinkDownCause INTEGER
  usrSS7SlotStatSBUSXmitPacketsOKCount Integer32
  usrSS7SlotStatSBUSXmitPacketsFailCount Integer32
  usrSS7SlotStatSBUSRcvdPacketsOKCount Integer32
  usrSS7SlotStatSBUSRcvdmitPacketsFailCount Integer32

Defined Values

usrSS7 1.3.6.1.4.1.429.4.77
The commWorks enterprise defined MIB objects for SS7.
MODULE-IDENTITY    

usrSS7Protocol 1.3.6.1.4.1.429.4.77.1
protocol being serviced:- HSS7I_SLAP_V2 or HSS7I_IPDC.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER slapv2(1), ipdc(2)  

usrSS7LANStartMethod 1.3.6.1.4.1.429.4.77.2
method to bring up TCP/IP connection to SS7GWP - HSS7I_LS_AUTO or HSS7I_LS_MANUAL.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

usrSS7SLAPgatewayIPAddress 1.3.6.1.4.1.429.4.77.3
The IP address of the SLAP SS7 gateway.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

usrSS7SLAPgatewayPort 1.3.6.1.4.1.429.4.77.4
The TCP port# of the SLAP SS7 gateway.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SLAPHeartbeatTimerNearEnd 1.3.6.1.4.1.429.4.77.5
The heartbeat timer settings.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SLAPChassisID 1.3.6.1.4.1.429.4.77.6
uniquely identify the TCH in a WAN.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SLAPNumberOfConnectionRetries 1.3.6.1.4.1.429.4.77.7
number of socket connection retries after lost it
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SLAPConnectionRetryInterval 1.3.6.1.4.1.429.4.77.8
socket connection retry interval after it is lost
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SLAPAllowedMissedHeartBeats 1.3.6.1.4.1.429.4.77.9
number of heartbeat missed from gw before action taken.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7StatSBUSXmitPacketsOKCount 1.3.6.1.4.1.429.4.77.16
the number of successful packets transmitted over the pBus connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7StatSBUSXmitPacketsFailCount 1.3.6.1.4.1.429.4.77.17
the number of packets failed to transmit over the pBus connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7StatSBUSRcvdPacketsOKCount 1.3.6.1.4.1.429.4.77.18
the number of successful packets received over the pBus connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7StatSBUSRcvdmitPacketsFailCount 1.3.6.1.4.1.429.4.77.19
the number of packets rejected by the pBus/Sbus client application.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7StatGWXmitByetsCount 1.3.6.1.4.1.429.4.77.20
the number of successful bytes transmitted over the SS7 GW connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7StatGWXmitPacketsCount 1.3.6.1.4.1.429.4.77.21
the number of packets transmited to the SS7 GW connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7StatGWRcvdBytesCount 1.3.6.1.4.1.429.4.77.22
the number of Bytes received over the SS7 GW connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7StatGWRcvdPacketsCount 1.3.6.1.4.1.429.4.77.23
the number of packets from SS7 GW.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7GWConnectionState 1.3.6.1.4.1.429.4.77.24
the state of the SS7 GW connection UP/DOWN
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7SLAPSecondaryGatewayIPAddress 1.3.6.1.4.1.429.4.77.25
The IP address of the SLAP SS7 gateway.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

usrSS7SLAPSecondaryGatewayPort 1.3.6.1.4.1.429.4.77.26
The TCP port# of the SLAP SS7 gateway.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SLAPHeartbeatTimerFarEnd 1.3.6.1.4.1.429.4.77.27
The heartbeat timer settings.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SlotTable 1.3.6.1.4.1.429.4.77.28
A table containing one row per slot in the chassis. Each row describes the characteristics of the slot
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UsrSS7SlotEntry

usrSS7SlotEntry 1.3.6.1.4.1.429.4.77.28.1
slot access table
Status: current Access: not-accessible
OBJECT-TYPE    
  UsrSS7SlotEntry  

usrSS7Slot 1.3.6.1.4.1.429.4.77.28.1.1
The slot number of this row.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

usrSS7SlotOwner 1.3.6.1.4.1.429.4.77.28.1.2
An indication if this slot's card has this Gateway card assigned as the owning gateway
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

usrSS7SlotType 1.3.6.1.4.1.429.4.77.28.1.3
An indicator that tells if this slot's (row's) data was created statically by configuration, or dynamically by the receipt of chassis awareness information from the NMC. Only static entries are saved to the configuration file. Dynamic entries are saved as static entries with an empty card type. If dynamic information is learned it replaces the information in a static entry. A dynamic entry cannot be changed through the CLI or an SNMP set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER static(1), dynamic(2)  

usrSS7SlotConnectionStatus 1.3.6.1.4.1.429.4.77.28.1.4
The status of the sbus connection to HDM at this slot.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7SlotTrace 1.3.6.1.4.1.429.4.77.28.1.5
SBUS Side SS7 Trace. enable(1) disable(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0)  

usrSS7SlotConnectToSlot 1.3.6.1.4.1.429.4.77.28.1.6
The Command to connect Hiper Arc to a SS7 channel in the given slot
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7SlotDisconnectToSlot 1.3.6.1.4.1.429.4.77.28.1.7
The Command to connect Hiper Arc to a SS7 channel in the given slot
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7ENFASLinkDownCause 1.3.6.1.4.1.429.4.77.28.1.8
The status of the SLAP Connection to the Secondary SS7 gateway.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), missingHDM(1), lostGWConnection(2), pBusError(3), manualDisconnect(4)  

usrSS7SlotStatSBUSXmitPacketsOKCount 1.3.6.1.4.1.429.4.77.28.1.9
the number of successful packets transmitted over the pBus connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7SlotStatSBUSXmitPacketsFailCount 1.3.6.1.4.1.429.4.77.28.1.10
the number of packets failed to transmit over the pBus connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7SlotStatSBUSRcvdPacketsOKCount 1.3.6.1.4.1.429.4.77.28.1.11
the number of successful packets received over the pBus connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7SlotStatSBUSRcvdmitPacketsFailCount 1.3.6.1.4.1.429.4.77.28.1.12
the number of packets rejected by the pBus/Sbus client application.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7CountersResetTime 1.3.6.1.4.1.429.4.77.29
Daily time we reset all the sbus statistics counters.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

usrSS7GWCountersResetTime 1.3.6.1.4.1.429.4.77.30
Daily time we reset all the SS7 GW connection statistics counters.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

usrSS7ConnectToGW 1.3.6.1.4.1.429.4.77.31
Command to connect to the SS7 GW manual mode
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

usrSS7SlapTrace 1.3.6.1.4.1.429.4.77.32
SLAP Side SS7 Trace. enable(1) disable(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0)  

usrSS7TraceOutput 1.3.6.1.4.1.429.4.77.33
The place where SS7 Trace output is send to. either to the console or syslog
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER screen(1), syslog(2)  

usrSS7DisconnectToGW 1.3.6.1.4.1.429.4.77.34
Command to disconnect the the existing conection to SS7 GW. this will tear down all the sbus connections to HDMs
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

usrSS7SendHeartBeat 1.3.6.1.4.1.429.4.77.35
Command to send a heartbeat to the existing conection to SS7 GW.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

usrSS7MissedHeartBeatsCounter 1.3.6.1.4.1.429.4.77.36
Command to send a heartbeat to the existing conection to SS7 GW.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usrSS7SLAPPrimaryGatewayConnectionStatus 1.3.6.1.4.1.429.4.77.37
The status of the SLAP Connection to the Primary SS7 gateway.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

usrSS7SLAPSecondaryGatewayConnectionStatus 1.3.6.1.4.1.429.4.77.38
The status of the SLAP Connection to the Secondary SS7 gateway.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

usrSS7SLAPPrimaryLinkDownCause 1.3.6.1.4.1.429.4.77.39
The status of the SLAP Connection to the Secondary SS7 gateway.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), heartbeatExpired(1), socketError(2), physicalLinkCut(3), manualDisconect(4)  

usrSS7SLAPSecondaryLinkDownCause 1.3.6.1.4.1.429.4.77.40
The status of the SLAP Connection to the Secondary SS7 gateway.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), heartbeatExpired(1), socketError(2), physicalLinkCut(3), manualDisconect(4)  

usrSS7SLAPUpTrap 1.3.6.1.4.1.429.4.77.41
if enabled sends TRAP each time the SLAP connection to the gateway goes UP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0)  

usrSS7SLAPDownTrap 1.3.6.1.4.1.429.4.77.42
if enabled sends TRAP each time the SLAP connection to the gateway goes Down.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0)  

usrSS7ENFASUpTrap 1.3.6.1.4.1.429.4.77.43
if enabled sends TRAP each time the ENFAS connection to the HDM goes Up.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0)  

usrSS7ENFASDownTrap 1.3.6.1.4.1.429.4.77.44
if enabled sends TRAP each time the ENFAS connection to the HDM goes Down.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0)  

usrSS7DropCallFlag 1.3.6.1.4.1.429.4.77.45
if enabled, drops all the calls, if the connection the GW is gone. after the timer expires .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

usrSS7DropCallTimer 1.3.6.1.4.1.429.4.77.46
When timer expires drops all the calls, when looses GW connection
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

usrSS7Traps 1.3.6.1.4.1.429.4.77.47
OBJECT IDENTIFIER    

usrSS7SLAPGatewayDownTrap 1.3.6.1.4.1.429.4.77.47.1
This trap is generated when SLAP connection to the SS7 Gateway goes down.
Status: current Access: read-write
NOTIFICATION-TYPE    

usrSS7SLAPGatewayUPTrap 1.3.6.1.4.1.429.4.77.47.2
This trap is generated when SLAP connection to the SS7 Gateway is restored.
Status: current Access: read-write
NOTIFICATION-TYPE    

usrSS7ENFASConnectionDownTrap 1.3.6.1.4.1.429.4.77.47.3
This trap is generated when ENFAS connection to the HiperDSP slot is Down.
Status: current Access: read-write
NOTIFICATION-TYPE    

usrSS7ENFASConnectionUPTrap 1.3.6.1.4.1.429.4.77.47.4
This trap is generated when ENFAS connection to the HiperDSP slot is restored.
Status: current Access: read-write
NOTIFICATION-TYPE