VALERE-DC-POWER-MIB

File: VALERE-DC-POWER-MIB.mib (102911 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
RFC1213-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
OBJECT-IDENTITY Counter32 Gauge32
Integer32 enterprises IpAddress
DisplayString TimeStamp TimeInterval
TestAndIncr AutonomousType TEXTUAL-CONVENTION
MODULE-COMPLIANCE OBJECT-GROUP sysUpTime

Defined Types

PositiveInteger  
This data type is a non-zero and non-negative value.
TEXTUAL-CONVENTION    
  INTEGER 1..2147483647  

NonNegativeInteger  
This data type is a non-negative value.
TEXTUAL-CONVENTION    
  INTEGER 0..2147483647  

VpwrSystemIdentEntry  
SEQUENCE    
  vpwrBayIndex PositiveInteger
  vpwrModuleIndex PositiveInteger
  vpwrModuleOID OBJECT IDENTIFIER
  vpwrModuleCurrent INTEGER
  vpwrModuleOperStatus INTEGER
  vpwrModuleCapacity INTEGER

VpwrPanelIdentEntry  
SEQUENCE    
  vpwrPanelBayIndex PositiveInteger
  vpwrPanelModuleIndex PositiveInteger
  vpwrPanelModuleOID OBJECT IDENTIFIER
  vpwrPanelModuleCurrent INTEGER
  vpwrPanelModuleOperStatus INTEGER
  vpwrPanelModuleCapacity INTEGER

VpwrBayctrlIdentEntry  
SEQUENCE    
  vpwrBayctrlIndex PositiveInteger
  vpwrBayctrlOID OBJECT IDENTIFIER
  vpwrBayctrlCurrent INTEGER
  vpwrBayctrlOperStatus INTEGER
  vpwrBayctrlCapacity INTEGER

VpwrLvdContactorConfigEntry  
SEQUENCE    
  vpwrLvdContactorIndex PositiveInteger
  vpwrLvdContactorWarningSetpoint PositiveInteger
  vpwrLvdContactorDisconnectSetpoint PositiveInteger
  vpwrLvdContactorReconnectSetpoint PositiveInteger
  vpwrLvdContactorReconnectDelayTimer PositiveInteger
  vpwrLvdContactorState PositiveInteger

VpwrAlarmEntry  
SEQUENCE    
  vpwrAlarmIndex PositiveInteger
  vpwrAlarmDescr AutonomousType
  vpwrAlarmTime TimeStamp

VpwrBatteryTempEntry  
SEQUENCE    
  vpwrBatteryTempIndex INTEGER
  vpwrBatteryTempName DisplayString
  vpwrBatteryTemp INTEGER

ThermalProbeEntry  
SEQUENCE    
  thermalProbeState INTEGER

VpwrTrapEntry  
SEQUENCE    
  vpwrTrapIpIndex INTEGER
  vpwrTrapIpAddress IpAddress
  vpwrTrapCriticality INTEGER

SysRelayConfigEntry  
SEQUENCE    
  sysRelayIndex INTEGER
  sysRelayDefaultName DisplayString
  sysRelayCustomName DisplayString
  sysRelayAlarmSeverity INTEGER

SysAlarmConfigEntry  
SEQUENCE    
  sysAlarmIndex INTEGER
  sysAlarmDefaultName DisplayString
  sysAlarmCustomName DisplayString
  sysAlarmSeverity INTEGER
  sysAlarmToRelayMapping DisplayString
  sysAlarmOperStatus INTEGER

SysAuxAlarmConfigEntry  
SEQUENCE    
  sysAuxAlarmIndex INTEGER
  sysAuxAlarmDefaultName DisplayString
  sysAuxAlarmCustomName DisplayString
  sysAuxAlarmSeverity INTEGER
  sysAuxAlarmToRelayMapping DisplayString
  sysAuxAlarmPolarity INTEGER
  sysAuxAlarmOperStatus INTEGER

VpwrRingerParameterEntry  
SEQUENCE    
  vpwrRingerIndex INTEGER
  vpwrRingerParameterAdminState INTEGER
  vpwrRingerParameterAcVoltage INTEGER
  vpwrRingerParameterDcVoltage INTEGER
  vpwrRingerParameterFrequency INTEGER

VpwrModuleIdentEntry  
SEQUENCE    
  vpwrModuleSerialNumber DisplayString
  vpwrModuleModelNumber DisplayString
  vpwrModuleFwVersion DisplayString
  vpwrModuleTestDate DisplayString
  vpwrModuleOperHours Counter32

VpwrPanelModuleIdentEntry  
SEQUENCE    
  vpwrPanelModuleSerialNumber DisplayString
  vpwrPanelModuleModelNumber DisplayString
  vpwrPanelModuleFwVersion DisplayString
  vpwrPanelModuleTestDate DisplayString
  vpwrPanelModuleOperHours Counter32

VpwrBayctrlModuleIdentEntry  
SEQUENCE    
  vpwrBayctrlSerialNumber DisplayString
  vpwrBayctrlModelNumber DisplayString
  vpwrBayctrlFwVersion DisplayString
  vpwrBayctrlTestDate DisplayString
  vpwrBayctrlOperHours Counter32

Defined Values

vpwrDcPowerMgt 1.3.6.1.4.1.13858
MIB Version 0.8 Need description here. History Add table to retrieve module inventory info MIB Version 0.7 Dec 1, 05 Fixed HP Openview error Fixed warnings generated by MG-SOFT Add table to retrieve rectifier inventory info MIB Version 0.6 Feb 10, 2004 Added additional traps. Defined Ringers and other modules. Feb 08, 2003 Changed vpwrTrapDestinationTable to vpwrTrapTable Corrected entry for vpwrTrapTable to be VpwrTrapTableEntry This fixes errors generated by MG-SOFT mib compiler. Oct 30, 2002 initial release - version 0.4
MODULE-IDENTITY    

vpwrDcPowerProducts 1.3.6.1.4.1.13858.1
OBJECT IDENTIFIER    

vpwrDcPowerSystem 1.3.6.1.4.1.13858.2
OBJECT IDENTIFIER    

vpwrDcPowerRectifier 1.3.6.1.4.1.13858.3
OBJECT IDENTIFIER    

vpwrDcPowerLvd 1.3.6.1.4.1.13858.4
OBJECT IDENTIFIER    

vpwrDcPowerTest 1.3.6.1.4.1.13858.5
OBJECT IDENTIFIER    

vpwrDcPowerModuleIdent 1.3.6.1.4.1.13858.6
OBJECT IDENTIFIER    

vpwrDcPowerBatteryGroup 1.3.6.1.4.1.13858.7
OBJECT IDENTIFIER    

vpwrDcPowerAlarmGroup 1.3.6.1.4.1.13858.8
OBJECT IDENTIFIER    

vpwrDcPowerSnmpConfig 1.3.6.1.4.1.13858.9
OBJECT IDENTIFIER    

vpwrDcPowerTraps 1.3.6.1.4.1.13858.10
OBJECT IDENTIFIER    

vpwrDcPowerTrapsMsgString 1.3.6.1.4.1.13858.11
OBJECT IDENTIFIER    

vpwrDcPowerRinger 1.3.6.1.4.1.13858.12
OBJECT IDENTIFIER    

vpwrDcPowerDcDcConverter 1.3.6.1.4.1.13858.13
OBJECT IDENTIFIER    

vpwrDcPowerDcAcInverter 1.3.6.1.4.1.13858.14
OBJECT IDENTIFIER    

vpwrDcPowerBayController 1.3.6.1.4.1.13858.15
OBJECT IDENTIFIER    

vpwrDcPowerIoModule 1.3.6.1.4.1.13858.16
OBJECT IDENTIFIER    

vpwrDcPowerDist 1.3.6.1.4.1.13858.17
OBJECT IDENTIFIER    

vpwrDcPowerTrio 1.3.6.1.4.1.13858.18
OBJECT IDENTIFIER    

vpwrSystemIdentGroup 1.3.6.1.4.1.13858.2.1
OBJECT IDENTIFIER    

vpwrSystemConfigGroup 1.3.6.1.4.1.13858.2.2
OBJECT IDENTIFIER    

vpwrSystemParameterGroup 1.3.6.1.4.1.13858.2.3
OBJECT IDENTIFIER    

vpwrSystemPanelIdentGroup 1.3.6.1.4.1.13858.2.4
OBJECT IDENTIFIER    

vpwrSystemBayctrlIdentGroup 1.3.6.1.4.1.13858.2.5
OBJECT IDENTIFIER    

vpwrLvdConfigGroup 1.3.6.1.4.1.13858.4.1
OBJECT IDENTIFIER    

vpwrLvdAlarmGroup 1.3.6.1.4.1.13858.4.2
OBJECT IDENTIFIER    

vpwrLvdTestGroup 1.3.6.1.4.1.13858.4.3
OBJECT IDENTIFIER    

vpwrRectifierConfigGroup 1.3.6.1.4.1.13858.3.1
OBJECT IDENTIFIER    

vpwrRectifierAlarmGroup 1.3.6.1.4.1.13858.3.2
OBJECT IDENTIFIER    

vpwrRectifierTestGroup 1.3.6.1.4.1.13858.3.3
OBJECT IDENTIFIER    

vpwrBatteryTempGroup 1.3.6.1.4.1.13858.7.1
OBJECT IDENTIFIER    

vpwrBatteryCurrentGroup 1.3.6.1.4.1.13858.7.2
OBJECT IDENTIFIER    

vpwrBatteryBoostGroup 1.3.6.1.4.1.13858.7.3
OBJECT IDENTIFIER    

vpwrBatteryDischargeTestGroup 1.3.6.1.4.1.13858.7.4
OBJECT IDENTIFIER    

vpwrRingerConfigGroup 1.3.6.1.4.1.13858.12.1
OBJECT IDENTIFIER    

vpwrRingerAlarmGroup 1.3.6.1.4.1.13858.12.2
OBJECT IDENTIFIER    

vpwrRingerTestGroup 1.3.6.1.4.1.13858.12.3
OBJECT IDENTIFIER    

vpwrDcDcConverterConfigGroup 1.3.6.1.4.1.13858.13.1
OBJECT IDENTIFIER    

vpwrDcDcConverterAlarmGroup 1.3.6.1.4.1.13858.13.2
OBJECT IDENTIFIER    

vpwrDcDcConverterTestGroup 1.3.6.1.4.1.13858.13.3
OBJECT IDENTIFIER    

vpwrDcAcInverterConfigGroup 1.3.6.1.4.1.13858.14.1
OBJECT IDENTIFIER    

vpwrDcAcInverterAlarmGroup 1.3.6.1.4.1.13858.14.2
OBJECT IDENTIFIER    

vpwrDcAcInverterTestGroup 1.3.6.1.4.1.13858.14.3
OBJECT IDENTIFIER    

vpwrIoModuleConfigGroup 1.3.6.1.4.1.13858.16.1
OBJECT IDENTIFIER    

vpwrIoModuleAlarmGroup 1.3.6.1.4.1.13858.16.2
OBJECT IDENTIFIER    

vpwrIoModuleTestGroup 1.3.6.1.4.1.13858.16.3
OBJECT IDENTIFIER    

vpwrIdentManufacturer 1.3.6.1.4.1.13858.2.1.1
The name of the DC Power manufacturer.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

vpwrIdentModel 1.3.6.1.4.1.13858.2.1.2
The DC Power Model designation.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

vpwrIdentControllerVersion 1.3.6.1.4.1.13858.2.1.3
The hardware/firmware version(s). This variable may or may not have the same value as vpwrIdentAgentSoftwareVersion.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

vpwrIdentAgentSoftwareVersion 1.3.6.1.4.1.13858.2.1.4
The SNMP agent software version. This variable may or may not have the same value as vpwrIdentControllerFirmwareVersion.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

vpwrIdentName 1.3.6.1.4.1.13858.2.1.5
A string identifying the system. This object should be set by the administrator.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

vpwrSystemIdentTable 1.3.6.1.4.1.13858.2.1.6
This table describes shelves and modules that make up the sysetm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrSystemIdentEntry

vpwrSystemIdentEntry 1.3.6.1.4.1.13858.2.1.6.1
An entry containing information applicable to a particular alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrSystemIdentEntry  

vpwrBayIndex 1.3.6.1.4.1.13858.2.1.6.1.1
Identifies Bay number that this module belongs to. The possible values are 1 through 16 limited by vpwrSystemShelfCapacity.
Status: current Access: read-only
OBJECT-TYPE    
  PositiveInteger  

vpwrModuleIndex 1.3.6.1.4.1.13858.2.1.6.1.2
This object identifies the module by its position in the shelf. Module numbering is left to right starting with module 1. So, the module in the first slot has an index of 1, the next module is 2 and so on.
Status: current Access: read-only
OBJECT-TYPE    
  PositiveInteger  

vpwrModuleOID 1.3.6.1.4.1.13858.2.1.6.1.3
It indicates the type of the module by specifiying its OID
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

vpwrModuleCurrent 1.3.6.1.4.1.13858.2.1.6.1.4
The meaning of this object depends upon the module type which is indicated by vpwrModuleOID as follows - Current for Rectifier module. - Not Applicable for LVD module
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrModuleOperStatus 1.3.6.1.4.1.13858.2.1.6.1.5
This object indicates current over all status of the module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleStatusOK(0), moduleStatusAlarm(1), moduleStatusDisabled(2), moduleStatusRingerAOn(3), moduleStatusRingerBOn(4), moduleStatusUnknown(5)  

vpwrModuleCapacity 1.3.6.1.4.1.13858.2.1.6.1.6
The meaning of this object depends upon the module type which is indicated by vpwrModuleOID as follows - Capacity for Rectifier module. - Not Applicable for LVD module
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrPanelIdentTable 1.3.6.1.4.1.13858.2.4.1
This table describes shelves and modules that make up the panels.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrPanelIdentEntry

vpwrPanelIdentEntry 1.3.6.1.4.1.13858.2.4.1.1
An entry containing information applicable to a particular panel making up the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrPanelIdentEntry  

vpwrPanelBayIndex 1.3.6.1.4.1.13858.2.4.1.1.1
Identifies bay number that this module belongs to. The possible values are 1 through 16, starting from the top.
Status: current Access: read-only
OBJECT-TYPE    
  PositiveInteger  

vpwrPanelModuleIndex 1.3.6.1.4.1.13858.2.4.1.1.2
This object identifies the module within the panel. The orentation of modules within the panel is mappable.
Status: current Access: read-only
OBJECT-TYPE    
  PositiveInteger  

vpwrPanelModuleOID 1.3.6.1.4.1.13858.2.4.1.1.3
It indicates the type of the module by specifiying its OID
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

vpwrPanelModuleCurrent 1.3.6.1.4.1.13858.2.4.1.1.4
This is the Current of the first shunt of the module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrPanelModuleOperStatus 1.3.6.1.4.1.13858.2.4.1.1.5
This object indicates over all status of the module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleStatusOK(0), moduleStatusAlarm(1)  

vpwrPanelModuleCapacity 1.3.6.1.4.1.13858.2.4.1.1.6
This is the overall Capacity of the module and is for reference only.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrBayctrlIdentTable 1.3.6.1.4.1.13858.2.5.1
This table describes bay controllers that make up the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrBayctrlIdentEntry

vpwrBayctrlIdentEntry 1.3.6.1.4.1.13858.2.5.1.1
An entry containing information applicable to a particular bay controller making up the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrBayctrlIdentEntry  

vpwrBayctrlIndex 1.3.6.1.4.1.13858.2.5.1.1.1
Identifies bay number that this module belongs to. The possible values are 0 through 15, starting from the top.
Status: current Access: read-only
OBJECT-TYPE    
  PositiveInteger  

vpwrBayctrlOID 1.3.6.1.4.1.13858.2.5.1.1.2
It indicates the type of the module by specifiying its OID
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

vpwrBayctrlCurrent 1.3.6.1.4.1.13858.2.5.1.1.3
This is the total output Current of the bay
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrBayctrlOperStatus 1.3.6.1.4.1.13858.2.5.1.1.4
This object indicates over all status of the bay
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleStatusOK(0), moduleStatusAlarm(1)  

vpwrBayctrlCapacity 1.3.6.1.4.1.13858.2.5.1.1.5
This is the overall Capacity of the bay and is for reference only.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrSystemTempCompensation 1.3.6.1.4.1.13858.2.2.1
This parameter enables/disables temperature compensation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tempCompDisabled(0), tempCompEnabled(1)  

vpwrSystemTempCompStartTemperature 1.3.6.1.4.1.13858.2.2.2
The temperature at which temperature compensation becomes active.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 25..60  

vpwrSystemTempCompStopVoltage 1.3.6.1.4.1.13858.2.2.3
When temperature compensation is active, vpwrSystemTempCompStopVoltage is the limit to which float voltage will be reduced. For example, to set this voltage to 51.75 volts enter a value of 5175.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrSystemTempCompensationSlope 1.3.6.1.4.1.13858.2.2.4
The rate at which float voltage is changed, within the specified limits, when temperature compensation is active.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

vpwrSystemThermalSenseType 1.3.6.1.4.1.13858.2.2.5
This parameter selects the temperature sensing point for temperature compensation (in)activation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER external(0), internal(1)  

vpwrSystemHVAlarmSetpoint 1.3.6.1.4.1.13858.2.2.6
System High voltage alarm voltage setting.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrSystemBDAlarmSetpoint 1.3.6.1.4.1.13858.2.2.7
System Battery Discharge voltage setting.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrSystemInternalTempLThreshold 1.3.6.1.4.1.13858.2.2.8
Temperature value at which temperature compensation inactive (clear) trap would be sent if temperature compensation was active when this value is reached.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrSystemInternalTempUThreshold 1.3.6.1.4.1.13858.2.2.9
Temperature value at which temperature compensation active (set) trap would be sent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrSystemShelfCapacity 1.3.6.1.4.1.13858.2.3.1
It describes the maximum number of shelves that can/are controlled by the controller. Each shelf is uniquely numbered in the range from 1 to vpwrShelfCapacity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

vpwrSystemVoltage 1.3.6.1.4.1.13858.2.3.2
The current system voltage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrSystemCurrent 1.3.6.1.4.1.13858.2.3.3
The current system current.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrSystemControllerState 1.3.6.1.4.1.13858.2.3.4
Current System state as shown on the enhanced display.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER systemControllerStateUnknown(0), systemControllerStateNormal(1), systemControllerStateChange(2), systemControllerStateAlarm(3), systemControllerStateMenu(4), systemControllerStateIrActive(5)  

vpwrSystemInternalTemperature 1.3.6.1.4.1.13858.2.3.5
The current controller internal temperature.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrSystemTempCompensationState 1.3.6.1.4.1.13858.2.3.6
Active or Inactive. Applicable only if temperature compensation is enabled. This means that the controller is temperature compensating the float voltage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER systemTempCompInactive(0), systemTempCompActive(1)  

vpwrSystemType 1.3.6.1.4.1.13858.2.3.7
This parameter describes the type of the system being managed. This object is set by Valere Power Inc.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sysTypeUnknow(0), sysType48V(1), sysType24V(2), sysType12V(3)  

vpwrLvdWarningSetpoint 1.3.6.1.4.1.13858.4.1.1
LVD Warning voltage setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrLvdDisconnectSetpoint 1.3.6.1.4.1.13858.4.1.2
LVD disconnect voltage setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrLvdReconnectSetpoint 1.3.6.1.4.1.13858.4.1.3
LVD Reconnect voltage setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrLvdReconnectDelayTimer 1.3.6.1.4.1.13858.4.1.4
The delay time, in seconds, before LVD is reconnected
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 20..240  

vpwrLvdContactorConfigTable 1.3.6.1.4.1.13858.4.1.5
This table describes shelves and modules that make up the sysetm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrLvdContactorConfigEntry

vpwrLvdContactorConfigEntry 1.3.6.1.4.1.13858.4.1.5.1
An entry containing information applicable to a particular module making up the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrLvdContactorConfigEntry  

vpwrLvdContactorIndex 1.3.6.1.4.1.13858.4.1.5.1.1
contactor index
Status: current Access: read-only
OBJECT-TYPE    
  PositiveInteger  

vpwrLvdContactorWarningSetpoint 1.3.6.1.4.1.13858.4.1.5.1.2
LVD Warning voltage setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  PositiveInteger  

vpwrLvdContactorDisconnectSetpoint 1.3.6.1.4.1.13858.4.1.5.1.3
LVD disconnect voltage setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  PositiveInteger  

vpwrLvdContactorReconnectSetpoint 1.3.6.1.4.1.13858.4.1.5.1.4
LVD Reconnect voltage setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  PositiveInteger  

vpwrLvdContactorReconnectDelayTimer 1.3.6.1.4.1.13858.4.1.5.1.5
The delay time, in seconds, before LVD is reconnected
Status: current Access: read-write
OBJECT-TYPE    
  PositiveInteger 0..240  

vpwrLvdContactorState 1.3.6.1.4.1.13858.4.1.5.1.6
The delay time, in seconds, before LVD is reconnected
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER contactorOpen(0), contactorClose(1)  

vpwrRectifierFVSetpoint 1.3.6.1.4.1.13858.3.1.1
System Float Voltage setting
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrRectifierHVSDSetpoint 1.3.6.1.4.1.13858.3.1.2
System High Voltage Shutdown voltage setting
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrRectifierCurrentLimitAdminState 1.3.6.1.4.1.13858.3.1.3
This parameter allows enabling or disabling boost.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rectCurrentLimitDisabled(0), rectCurrentLimitEnabled(1)  

vpwrRectifierCurrentLimit 1.3.6.1.4.1.13858.3.1.4
Rectifier current limit setpoint
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..200  

vpwrAlarmsPresent 1.3.6.1.4.1.13858.8.1
The present number of active alarm conditions.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

vpwrAlarmTable 1.3.6.1.4.1.13858.8.2
A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The vpwrAlarmIndex, for each type of module starts at 1 and is limited by the total number of alarams that can be generated by the module. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), vpwrAlarmDescr, to allow a single table to reflect alarms for different type of modules. The number of rows in the table at any given time is reflected by the value of vpwrAlarmsPresent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrAlarmEntry

vpwrAlarmEntry 1.3.6.1.4.1.13858.8.2.1
An entry containing information applicable to a particular alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrAlarmEntry  

vpwrAlarmIndex 1.3.6.1.4.1.13858.8.2.1.1
Identifies the alarm associated with the module. It is unique on per module type basis. For example, multiple rectifiers can have the same alarm and therefore same vpwrAlarmIndex active at any one time.
Status: current Access: read-only
OBJECT-TYPE    
  PositiveInteger  

vpwrAlarmDescr 1.3.6.1.4.1.13858.8.2.1.2
A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.
Status: current Access: read-only
OBJECT-TYPE    
  AutonomousType  

vpwrAlarmTime 1.3.6.1.4.1.13858.8.2.1.3
The value of sysUpTime when the alarm condition was detected.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

vpwrBatteryTempTable 1.3.6.1.4.1.13858.7.1.1
This table describes battery temperature probes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrBatteryTempEntry

vpwrBatteryTempEntry 1.3.6.1.4.1.13858.7.1.1.1
An entry containing information applicable to a particular temperature probe.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrBatteryTempEntry  

vpwrBatteryTempIndex 1.3.6.1.4.1.13858.7.1.1.1.1
Index into temperature table
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrBatteryTempName 1.3.6.1.4.1.13858.7.1.1.1.2
A string identifying probe location.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

vpwrBatteryTemp 1.3.6.1.4.1.13858.7.1.1.1.3
Current temperature as recorded by the probe.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrBatteryTempLThreshold 1.3.6.1.4.1.13858.7.1.2
Temperature value at which a clear trap would be sent. All three battery temperature must be at or below this value to trigger this trap.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrBatteryTempUThreshold 1.3.6.1.4.1.13858.7.1.3
Temperature value at which a set trap would be sent. Any one of the three battery temperatures at or exceeding this limit would trigger the trap.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

batteryTempCompensation 1.3.6.1.4.1.13858.7.1.4
This parameter enables/disables temperature compensation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tempCompDisabled(0), tempCompEnabled(1)  

batteryTempCompHighStartTemperature 1.3.6.1.4.1.13858.7.1.5
The temperature at which temperature compensation becomes active.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 25..60  

batteryTempCompHighStopVoltage 1.3.6.1.4.1.13858.7.1.6
When temperature compensation is active, batteryTempCompHighStopVoltage is the limit to which float voltage will be reduced. For example, to set this voltage to 51.75 volts enter a value of 5175.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

batteryTempCompHighSlope 1.3.6.1.4.1.13858.7.1.7
The rate at which float voltage is changed, within the specified limits, when temperature compensation is active.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

batteryTempCompLowStartTemperature 1.3.6.1.4.1.13858.7.1.8
The temperature at which temperature compensation becomes active.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

batteryTempCompLowStopVoltage 1.3.6.1.4.1.13858.7.1.9
When temperature compensation is active, batteryTempCompLowStopVoltage is the limit to which float voltage will be reduced. For example, to set this voltage to 51.75 volts enter a value of 5175.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

batteryTempCompLowSlope 1.3.6.1.4.1.13858.7.1.10
The rate at which float voltage is changed, within the specified limits, when temperature compensation is active.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

batteryTempCompRunawayTemperature 1.3.6.1.4.1.13858.7.1.11
The temperature at which system voltage will be set to batteryTempCompRunawayStopVoltage.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 25..60  

batteryTempCompRunawayStopVoltage 1.3.6.1.4.1.13858.7.1.12
When temperature compensation is enabled, float voltage will be reduced to batteryTempCompRunawayStopVoltage if temperature reaches batteryTempCompRunawayTemperature.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

batteryTempCompSenseSource 1.3.6.1.4.1.13858.7.1.13
This parameter selects the temperature sensing point for temperature compensation (in)activation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER external(0), internal(1)  

batteryTempCompRunawayState 1.3.6.1.4.1.13858.7.1.14
This parameter selects the temperature sensing point for temperature compensation (in)activation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(0), active(1)  

thermalProbeTable 1.3.6.1.4.1.13858.7.1.15
This table describes battery temperature probes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ThermalProbeEntry

thermalProbeEntry 1.3.6.1.4.1.13858.7.1.15.1
An entry containing information applicable to a particular temperature probe.
Status: current Access: not-accessible
OBJECT-TYPE    
  ThermalProbeEntry  

thermalProbeState 1.3.6.1.4.1.13858.7.1.15.1.1
State of thermal probe.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(0), present(1), removed(2), shorted(3)  

vpwrTrapTable 1.3.6.1.4.1.13858.9.1
A list of possible trap destinations depending upon the criticality of the trap.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrTrapEntry

vpwrTrapEntry 1.3.6.1.4.1.13858.9.1.1
An entry containing information applicable to a particular trap destination.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrTrapEntry  

vpwrTrapIpIndex 1.3.6.1.4.1.13858.9.1.1.1
Trap Entry Index
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrTrapIpAddress 1.3.6.1.4.1.13858.9.1.1.2
Trap destination IP Address
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

vpwrTrapCriticality 1.3.6.1.4.1.13858.9.1.1.3
Criticality of traps sent to this IP Address
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

vpwrReadCommunityString 1.3.6.1.4.1.13858.9.2
This allows setting password to be able to do Get operations
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..8)  

vpwrWriteCommunityString 1.3.6.1.4.1.13858.9.3
This allows setting password to be able to do Get and Set operations. The read-access is not allowed in the actual implementation.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..8)  

vpwrTrapCommunityString 1.3.6.1.4.1.13858.9.4
This allows setting community string required for the trap to be accepted at the destination.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..8)  

vpwrTrapPowerMajorAlarm 1
Major Alarm
TRAP-TYPE    

vpwrTrapPowerMinorAlarm 2
Minor Alarm
TRAP-TYPE    

vpwrTrapACFAlarm 3
AC Fail Alarm
TRAP-TYPE    

vpwrTrapHVAlarm 4
High Voltage Warning Alarm
TRAP-TYPE    

vpwrTrapHVSDAlarm 5
High Voltage Shutdown Alarm
TRAP-TYPE    

vpwrTrapBDAlarm 6
Battery on Discharge Alarm
TRAP-TYPE    

vpwrTrapLVDWarningAlarm 7
LVD Warning Alarm
TRAP-TYPE    

vpwrTrapLVDOpenAlarm 8
LVD Open Alarm
TRAP-TYPE    

vpwrTrapDistAlarm 9
Distribution Open Alarm
TRAP-TYPE    

vpwrTrapAuxAlarm 10
Auxiliary System Alarm
TRAP-TYPE    

vpwrTrapSystemRedundancyAlarm 11
System Redundant Capacity Alarm
TRAP-TYPE    

vpwrTrapIShareAlarm 12
Rectifier Current Share Alarm
TRAP-TYPE    

vpwrTrapModuleFailAlarm 13
Single Rectifier Fail Alarm
TRAP-TYPE    

vpwrTrapMultipleModuleFailAlarm 14
Multiple Rectifier Fail Alarm
TRAP-TYPE    

vpwrTrapModuleCommAlarm 15
Module Communication Alarm
TRAP-TYPE    

vpwrTrapSystemOverTemperatureAlarm 16
System Over Temperature Alarm
TRAP-TYPE    

vpwrTrapSystemOK 17
SYSTEM OK - No Active Alarms
TRAP-TYPE    

vpwrTrapModuleInserted 18
A new module has been inserted into the system.
TRAP-TYPE    

vpwrTrapModuleRemoved 19
A module has been removed from the system.
TRAP-TYPE    

vpwrTrapThermalCompActive 20
Thermal compensation has become active.
TRAP-TYPE    

vpwrTrapThermalCompInactive 21
Thermal compensation has been de-activated.
TRAP-TYPE    

vpwrTrapInternalTempAlarmSet 22
Internal Temperature upper threshold exceeded.
TRAP-TYPE    

vpwrTrapInternalTempAlarmCleared 23
Internal Temperature within limits
TRAP-TYPE    

vpwrTrapBatteryTempAlarmSet 24
At least one Battery Temperature exceeded upper threshold.
TRAP-TYPE    

vpwrTrapBatteryTempAlarmCleared 25
All Battery Temperatures within limits.
TRAP-TYPE    

vpwrTrapLoginFail 26
Admin login failed due to wrong username/password.
TRAP-TYPE    

vpwrTrapLoginSuccess 27
Admin login successful.
TRAP-TYPE    

vpwrTrapLogout 28
Admin logout.
TRAP-TYPE    

vpwrTrapAdminPwdChange 29
Config change submitted with invalid access.
TRAP-TYPE    

vpwrTrapIllegalConfigSubmit 30
Config change submitted with invalid access.
TRAP-TYPE    

vpwrTrapCfgChange 31
Config change submitted.
TRAP-TYPE    

vpwrTrapClearEventHistory 32
Clear Event history buffer clear request.
TRAP-TYPE    

vpwrTrapSwDownloadNoReboot 33
System software upgrade without reboot.
TRAP-TYPE    

vpwrTrapSwDownloadAndReboot 34
System reboot due to software upgrade.
TRAP-TYPE    

vpwrTrapSystemClockChange 35
System clock updated.
TRAP-TYPE    

vpwrTrapModuleAlarm 36
Module Alarm.
TRAP-TYPE    

vpwrTrapOIDChange 37
Change in OID.
TRAP-TYPE    

vpwrTrapThermalRunaway 38
Thermal Runaway Alarm.
TRAP-TYPE    

vpwrTrapBatteryDischargeTestAlarm 39
System Voltage dropped to BDT Alarm Setpoint.
TRAP-TYPE    

vpwrTrapRingerAAlarm 40
Ringer A Fail Alarm.
TRAP-TYPE    

vpwrTrapRingerBAlarm 41
Ringer B Fail Alarm.
TRAP-TYPE    

vpwrTrapSingleRingerAlarm 42
Single Ringer Fail Alarm.
TRAP-TYPE    

vpwrTrapMultipleRingerAlarm 43
Multiple Ringer Fail Alarm.
TRAP-TYPE    

vpwrTrapThermalProbeAlarm 44
Thermal Probe Missing Alarm.
TRAP-TYPE    

vpwrTrapRingerCommAlarm 45
Ringer Communication Alarm.
TRAP-TYPE    

vpwrTrapDistributionCommAlarm 46
Distribution Communication Alarm.
TRAP-TYPE    

vpwrTrapConverterAlarm 47
Single Converter Fail Alarm.
TRAP-TYPE    

vpwrTrapMultipleConvFailAlarm 48
Multiple Converter Fail Alarm.
TRAP-TYPE    

vpwrTrapUnmappedAddressAlarm 49
Unmapped I2C Address.
TRAP-TYPE    

vpwrTrapConfigErrorAlarm 50
Configuration Error.
TRAP-TYPE    

vpwrTrapDisplayFirmwareMismatchAlarm 51
Display Firmware Mismatch.
TRAP-TYPE    

vpwrTrapConverterInputFailAlarm 52
Converter Input Fail Alarm.
TRAP-TYPE    

vpwrTrapBatteryRechgIlimitFailAlarm 53
Battery Recharge Current Limit Fail.
TRAP-TYPE    

vpwrTrapSystemAlive 54
Periodic Keepalive trap.
TRAP-TYPE    

vpwrLvdAlarmContactorOpen 1.3.6.1.4.1.13858.4.2.1
Contactor open
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrLvdAlarmCBOpen 1.3.6.1.4.1.13858.4.2.2
Circuit Breaker open
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrTrapLvdFuseOpen 1.3.6.1.4.1.13858.4.2.3
Fuse open
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrLvdAlarmWarning 1.3.6.1.4.1.13858.4.2.4
Plant Voltage below warning threshold
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmDCFail 1.3.6.1.4.1.13858.3.2.1
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmBoostFail 1.3.6.1.4.1.13858.3.2.2
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmACFail 1.3.6.1.4.1.13858.3.2.3
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmHVSD 1.3.6.1.4.1.13858.3.2.4
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmFanFail 1.3.6.1.4.1.13858.3.2.5
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmAmbTemp 1.3.6.1.4.1.13858.3.2.6
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmIntTemp 1.3.6.1.4.1.13858.3.2.7
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmIShare 1.3.6.1.4.1.13858.3.2.8
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmUV 1.3.6.1.4.1.13858.3.2.9
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmLowVoltage 1.3.6.1.4.1.13858.3.2.10
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmReserved 1.3.6.1.4.1.13858.3.2.11
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmDCEnable 1.3.6.1.4.1.13858.3.2.12
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmRemoteShutdown 1.3.6.1.4.1.13858.3.2.13
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmModDisableShutdown 1.3.6.1.4.1.13858.3.2.14
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmShortPinShutdown 1.3.6.1.4.1.13858.3.2.15
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrRectAlarmBoostComm 1.3.6.1.4.1.13858.3.2.16
Status: current Access: read-write
OBJECT-IDENTITY    

vpwrTrapsMsgString 1.3.6.1.4.1.13858.11.1
Place holder for trap notification message string
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..127)  

vpwrTrapUserIpAddress 1.3.6.1.4.1.13858.11.2
Place holder for IP address of the user accessing the system
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

vpwrTrapEventTimeStamp 1.3.6.1.4.1.13858.11.3
Place holder for time-stamp.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

sysRelayConfigTable 1.3.6.1.4.1.13858.8.3
This table describes battery temperature probes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysRelayConfigEntry

sysRelayConfigEntry 1.3.6.1.4.1.13858.8.3.1
An entry containing information applicable to a particular temperature probe.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysRelayConfigEntry  

sysRelayIndex 1.3.6.1.4.1.13858.8.3.1.1
Index into temperature table
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

sysRelayDefaultName 1.3.6.1.4.1.13858.8.3.1.2
A string identifying probe location.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysRelayCustomName 1.3.6.1.4.1.13858.8.3.1.3
A string identifying probe location.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysRelayAlarmSeverity 1.3.6.1.4.1.13858.8.3.1.4
Current temperature as recorded by the probe.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER alarmNone(0), alarmMajor(1), alarmMinor(2), alarmMajorAndMinor(3)  

sysAlarmConfigTable 1.3.6.1.4.1.13858.8.4
This table describes battery temperature probes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysAlarmConfigEntry

sysAlarmConfigEntry 1.3.6.1.4.1.13858.8.4.1
An entry containing information applicable to a particular temperature probe.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysAlarmConfigEntry  

sysAlarmIndex 1.3.6.1.4.1.13858.8.4.1.1
Index into temperature table
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

sysAlarmDefaultName 1.3.6.1.4.1.13858.8.4.1.2
A string identifying probe location.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysAlarmCustomName 1.3.6.1.4.1.13858.8.4.1.3
A string identifying probe location.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysAlarmSeverity 1.3.6.1.4.1.13858.8.4.1.4
Alarm Severity as denoted by Major and Minor Alarm Mask
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), major(1), minor(2), majorAndMinor(3)  

sysAlarmToRelayMapping 1.3.6.1.4.1.13858.8.4.1.5
No additional mapping = 0 Map to Relay A = 1 Map to Relay B = 2 Map to Relay C = 4 Map to Relay D = 8 Map to Relay E = 16 Map to Relay F = 32 Map to Relay A and B = (1 + 2) and so on The major/minor classification of alarms automatically associates it with Major/Minor relay. Assigning a null mapping here does not override sysRelayAlarmSeverity for the alarm. It should be used to define mapping to additional relays.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysAlarmOperStatus 1.3.6.1.4.1.13858.8.4.1.6
Indicates current alarm status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(0), active(1)  

sysAuxAlarmConfigTable 1.3.6.1.4.1.13858.8.5
This table describes battery temperature probes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysAuxAlarmConfigEntry

sysAuxAlarmConfigEntry 1.3.6.1.4.1.13858.8.5.1
An entry containing information applicable to a particular temperature probe.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysAuxAlarmConfigEntry  

sysAuxAlarmIndex 1.3.6.1.4.1.13858.8.5.1.1
Index into temperature table
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

sysAuxAlarmDefaultName 1.3.6.1.4.1.13858.8.5.1.2
A string identifying probe location.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysAuxAlarmCustomName 1.3.6.1.4.1.13858.8.5.1.3
A string identifying probe location.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysAuxAlarmSeverity 1.3.6.1.4.1.13858.8.5.1.4
Aux Alarm Severity
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), major(1), minor(2), majorAndMinor(3)  

sysAuxAlarmToRelayMapping 1.3.6.1.4.1.13858.8.5.1.5
No additional mapping = 0 Map to Relay A = 1 Map to Relay B = 2 Map to Relay C = 4 Map to Relay D = 8 Map to Relay E = 16 Map to Relay F = 32 Map to Relay A and B = (1 + 2) and so on The major/minor classification of alarms automatically associates it with Major/Minor relay. Assigning a null mapping here does not override sysRelayAlarmSeverity for the alarm. It should be used to define mapping to additional relays.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

sysAuxAlarmPolarity 1.3.6.1.4.1.13858.8.5.1.6
Current temperature as recorded by the probe.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER alarmOnOpen(0), alarmOnClose(1)  

sysAuxAlarmOperStatus 1.3.6.1.4.1.13858.8.5.1.7
Indicates current alarm status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(0), active(1)  

sysAlarmComFailState 1.3.6.1.4.1.13858.8.6
Enable/Disable generation of comm fail alarm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), other(2)  

sysAlarmIShareState 1.3.6.1.4.1.13858.8.7
Enable/Disable generation of current share alarm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), other(2)  

sysAlarmRedundancyState 1.3.6.1.4.1.13858.8.8
Enable/Disable generation of redundancy alarm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), nPlus1(1), nPlus2(2)  

vpwrRingerParameterTable 1.3.6.1.4.1.13858.12.1.1
A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The vpwrAlarmIndex, for each type of module starts at 1 and is limited by the total number of alarams that can be generated by the module. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), vpwrAlarmDescr, to allow a single table to reflect alarms for different type of modules. The number of rows in the table at any given time is reflected by the value of vpwrAlarmsPresent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrRingerParameterEntry

vpwrRingerParameterEntry 1.3.6.1.4.1.13858.12.1.1.1
An entry containing information applicable to a particular alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrRingerParameterEntry  

vpwrRingerIndex 1.3.6.1.4.1.13858.12.1.1.1.1
This parameter allows selecting ringer A or Ringer B as the active ringer.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vpwrRingerParameterAdminState 1.3.6.1.4.1.13858.12.1.1.1.2
This parameter allows selecting ringer A or Ringer B as the active ringer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ringerDisabled(0), ringerAOn(1), ringerBOn(2)  

vpwrRingerParameterAcVoltage 1.3.6.1.4.1.13858.12.1.1.1.3
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 7000..11000  

vpwrRingerParameterDcVoltage 1.3.6.1.4.1.13858.12.1.1.1.4
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..5600  

vpwrRingerParameterFrequency 1.3.6.1.4.1.13858.12.1.1.1.5
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 17..50  

vpwrRingerNumberPresent 1.3.6.1.4.1.13858.12.1.2
The present number of active alarm conditions.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

vpwrRingerAlarmaAFailed 1.3.6.1.4.1.13858.12.2.1
Ringer A Failed
Status: current Access: read-only
OBJECT-IDENTITY    

vpwrRingerAlarmAOTemp 1.3.6.1.4.1.13858.12.2.2
Ringer A Heatsink Over-Temperature
Status: current Access: read-only
OBJECT-IDENTITY    

vpwrRingerAlarmAOCurrent 1.3.6.1.4.1.13858.12.2.3
Ringer A Over-Current protection
Status: current Access: read-only
OBJECT-IDENTITY    

vpwrRingerAlarmaBFailed 1.3.6.1.4.1.13858.12.2.4
Ringer A Failed
Status: current Access: read-only
OBJECT-IDENTITY    

vpwrRingerAlarmBOverTemp 1.3.6.1.4.1.13858.12.2.5
Ringer A Heatsink Over-Temperature
Status: current Access: read-only
OBJECT-IDENTITY    

vpwrRingerAlarmBOverCurrent 1.3.6.1.4.1.13858.12.2.6
Ringer A Over-Current protection
Status: current Access: read-only
OBJECT-IDENTITY    

vpwrBoostAdminState 1.3.6.1.4.1.13858.7.3.1
This parameter allows enabling or disabling boost.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER boostDisabled(0), boostEnabled(1)  

vpwrBoostVoltage 1.3.6.1.4.1.13858.7.3.2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 7000..11000  

vpwrBoostDuration 1.3.6.1.4.1.13858.7.3.3
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

vpwrBoostOperState 1.3.6.1.4.1.13858.7.3.4
This parameter allows starting or stoping boost if it is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER boostInactive(0), boostActive(1)  

vpwrBatteryCurrentLimitAdminState 1.3.6.1.4.1.13858.7.2.1
This parameter allows enabling or disabling battery current limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER battetyCurrentLimitDisabled(0), battetyCurrentLimitEnabled(1)  

vpwrBattetyCurrentLimitValue 1.3.6.1.4.1.13858.7.2.2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..40  

vpwrBattetyCurrentValue 1.3.6.1.4.1.13858.7.2.3
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 5..40  

vpwrBDTAdminState 1.3.6.1.4.1.13858.7.4.1
Enable /Disable Battery Discharge Test execution.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bdtDisabled(0), bdtEnabled(1)  

vpwrBDTDuration 1.3.6.1.4.1.13858.7.4.2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 17..50  

vpwrBDTAlarmVoltage 1.3.6.1.4.1.13858.7.4.3
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 7000..11000  

vpwrBDTAbortVoltage 1.3.6.1.4.1.13858.7.4.4
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..5600  

vpwrBDTAlarmCoefficient 1.3.6.1.4.1.13858.7.4.5
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

vpwrBDTOperState 1.3.6.1.4.1.13858.7.4.6
Start/Stop Battery Discharge Test execution.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bdtInactive(0), bdtActive(1)  

vpwrBDTClearAlarm 1.3.6.1.4.1.13858.7.4.7
Clears any active bdt alarm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bdtNoAlarm(0), bdtAlarmPresent(1)  

vpwrModuleIdentTable 1.3.6.1.4.1.13858.6.1
This table describes shelves and modules that make up the sysetm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrModuleIdentEntry

vpwrModuleIdentEntry 1.3.6.1.4.1.13858.6.1.1
An entry containing information applicable to a particular Module.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrModuleIdentEntry  

vpwrModuleSerialNumber 1.3.6.1.4.1.13858.6.1.1.1
Serial Number of the module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrModuleModelNumber 1.3.6.1.4.1.13858.6.1.1.2
Model Number of the module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrModuleFwVersion 1.3.6.1.4.1.13858.6.1.1.3
Firmware version of the module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrModuleTestDate 1.3.6.1.4.1.13858.6.1.1.4
Date when the module was last tested.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrModuleOperHours 1.3.6.1.4.1.13858.6.1.1.5
Cumulative Operating Hours.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vpwrPanelModuleIdentTable 1.3.6.1.4.1.13858.6.2
This table describes shelves and modules that make up the sysetm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrPanelModuleIdentEntry

vpwrPanelModuleIdentEntry 1.3.6.1.4.1.13858.6.2.1
An entry containing information applicable to a particular alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrPanelModuleIdentEntry  

vpwrPanelModuleSerialNumber 1.3.6.1.4.1.13858.6.2.1.1
Serial Number of the module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrPanelModuleModelNumber 1.3.6.1.4.1.13858.6.2.1.2
Model Number of the module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrPanelModuleFwVersion 1.3.6.1.4.1.13858.6.2.1.3
Firmware version of the module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrPanelModuleTestDate 1.3.6.1.4.1.13858.6.2.1.4
Date when the module was last tested.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrPanelModuleOperHours 1.3.6.1.4.1.13858.6.2.1.5
Cumulative Operating Hours.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

vpwrBayctrlModuleIdentTable 1.3.6.1.4.1.13858.6.3
This table describes bay controllers that make up the sysetm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VpwrBayctrlModuleIdentEntry

vpwrBayctrlModuleIdentEntry 1.3.6.1.4.1.13858.6.3.1
An entry containing information applicable to a particular bay controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  VpwrBayctrlModuleIdentEntry  

vpwrBayctrlSerialNumber 1.3.6.1.4.1.13858.6.3.1.1
Serial Number of the bay controller
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrBayctrlModelNumber 1.3.6.1.4.1.13858.6.3.1.2
Model Number of the bay controller.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrBayctrlFwVersion 1.3.6.1.4.1.13858.6.3.1.3
Firmware version of the bay controller.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrBayctrlTestDate 1.3.6.1.4.1.13858.6.3.1.4
Date when the bayctrl was last tested.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vpwrBayctrlOperHours 1.3.6.1.4.1.13858.6.3.1.5
Cumulative Operating Hours.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32