VERILINK-ENTERPRISE-NCMDSU-MIB

File: VERILINK-ENTERPRISE-NCMDSU-MIB.mib (40699 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
VERILINK-ENTERPRISE-NCMALARM-MIB

Imported symbols

Gauge DisplayString OBJECT-TYPE
ncm-dsu ncm-dds ncm-dbu

Defined Types

NcmdsuCommonEntry  
SEQUENCE    
  ncmdsuNIDIndex INTEGER
  ncmdsuIndex INTEGER
  ncmdsuPortType INTEGER
  ncmdsuPortLoopback INTEGER
  ncmdsuPortTest INTEGER

NcmdsuConfigEntry  
SEQUENCE    
  ncmdsuNIDConfigIndex INTEGER
  ncmdsuLineIndex INTEGER
  ncmdsubus INTEGER
  ncmdsuPortChannel DisplayString
  ncmdsuPortConfiguration INTEGER
  ncmcsushelf INTEGER
  ncmcsuslot INTEGER
  ncmdsuAlarmEnable INTEGER
  ncmdsuLosLead INTEGER
  ncmdsuTimingSource INTEGER
  ncmdsuDTESpeed INTEGER

NcmdsustatEntry  
SEQUENCE    
  ncmdsuNIDstatIndex INTEGER
  ncmdsustatIndex INTEGER
  ncmdsuPortLowbattery INTEGER
  ncmdsuPortLOSstatus INTEGER
  ncmdsuPortblockerrorcounter Gauge
  ncmdsuPortTestSeconds Gauge
  ncmdsuPortrateper8000 INTEGER
  ncmdsuPortLeadStatus1 INTEGER
  ncmdsuPortLeadStatus2 INTEGER
  ncmdbuPrimaryLineStatus INTEGER
  ncmdbuLineStatus INTEGER
  ncmdbuSwitchBy INTEGER
  ncmdbuReceivedCode INTEGER
  ncmdsuPortTestResults INTEGER
  ncmdsuPortDiagStatus INTEGER

NcmddsMainConfigEntry  
SEQUENCE    
  ncmddsNIDMainConfigIndex INTEGER
  ncmddsMainLineIndex INTEGER
  ncmddsdsubus INTEGER
  ncmddsPortChannel DisplayString
  ncmddsPortConfiguration INTEGER
  ncmddscsushelf INTEGER
  ncmddscsuslot INTEGER
  ncmddsLosLead INTEGER

NcmddsConfigEntry  
SEQUENCE    
  ncmddsNIDConfigIndex INTEGER
  ncmddsConfigLineIndex INTEGER
  ncmddsPortLoopEnable INTEGER
  ncmddsPortReceiveLoopCode INTEGER
  ncmddsPortRemoteLoopCode INTEGER
  ncmddsPortAlarmEnable INTEGER
  ncmddsPortAlarmClearDelayTime INTEGER
  ncmddsPortAbnormalStationCodeThreshold INTEGER
  ncmddsPortControlModeIdleThreshold INTEGER
  ncmddsPortMuxOutofSyncThreshold INTEGER
  ncmddsPortUnAssignedMuxChannelThreshold INTEGER
  ncmddsPortGroup1Codes INTEGER
  ncmddsPort56KStatus INTEGER
  ncmddsPortReceived56KCode INTEGER
  ncmddsmode INTEGER
  ncmddsLatchingLoopbackType INTEGER
  ncmddsLatchingLoopbackDevNo INTEGER

NcmdbuMainConfigEntry  
SEQUENCE    
  ncmdbuNIDMainConfigIndex INTEGER
  ncmdbuMainLineIndex INTEGER
  ncmdbudsubus INTEGER
  ncmdbuPortChannel DisplayString
  ncmdbuPortConfiguration INTEGER
  ncmdbucsushelf INTEGER
  ncmdbucsuslot INTEGER
  ncmdbuLosLead INTEGER

NcmdbuConfigEntry  
SEQUENCE    
  ncmdbuNIDConfigIndex INTEGER
  ncmdbuLineIndex INTEGER
  ncmdbuAllOnesSwitchOverTime INTEGER
  ncmdbuSwitchOnBERThresholdExceeded INTEGER
  ncmdbuDialBackupMode INTEGER
  ncmdbuBackupConnection INTEGER
  ncmdbumode INTEGER
  ncmdbuLoopType INTEGER

Defined Values

ncmdsuCommonTable 3.1.3022.2000
The ncmdsu information table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NcmdsuCommonEntry

ncmdsuCommonEntry 3.1.3022.2000.1
An entry in the ncmdsu information table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NcmdsuCommonEntry  

ncmdsuNIDIndex 3.1.3022.2000.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsuIndex 3.1.3022.2000.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsuPortType 3.1.3022.2000.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), v35(2), rs-449(3), eia530(4), rS-232(5), wrong-DIM(6), unknown(7)  

ncmdsuPortLoopback 3.1.3022.2000.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), inband-loop(2), local-loop(3), sending-loop-up(4), sending-loop-down(5), verilink-loop-up(6), verilink-loop-down(7), local-loop-up(8), local-loop-down(9), v54-loop-up(10), v54-loop-down(11), dds-latching-loop-up(12), dds-latching-loop-down(13), dds-nonlatching-loop-up(14), dds-nonlatching-loop-down(15), ft1-loop-up(16), ft1-loop-down(17)  

ncmdsuPortTest 3.1.3022.2000.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-test(1), start-test(2), run-ber-test(3), stop-ber-test(4), test-511(5), test-2047(6)  

ncmdsuConfigTable 3.1.3022.2001
The ncmdsu Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NcmdsuConfigEntry

ncmdsuConfigEntry 3.1.3022.2001.1
An entry in the ncmdsu Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NcmdsuConfigEntry  

ncmdsuNIDConfigIndex 3.1.3022.2001.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmdsuLineIndex 3.1.3022.2001.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsubus 3.1.3022.2001.1.3
The ncmdsu bus type for Port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), busA(2), busB(3), busC(4)  

ncmdsuPortChannel 3.1.3022.2001.1.4
This variable indicates the channel assignment for the ncmdsu for the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

ncmdsuPortConfiguration 3.1.3022.2001.1.5
This variable indicates the configuration bits for port. The configuration can be set by setting the relevant bit to 1 and reset by setting the relevant bit to zero. Bit Value Name Description 0 set the ncmdsu port configuration to zero 0 1 64k set uses 8bits of data/64kbps. 1 2 LEN set enable loop code and loop commands 2 4 INV set invert the channelized data 3 8 SCR set to scramble channelized data. 4 16 CLK1 DTE transmit clock select bits 5 32 CLK2 DTE transmit clock select bits 6 64 TU set port as a timing unit 7 128 ALM set if DIU has to report alarms to SAM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmcsushelf 3.1.3022.2001.1.6
This variable indicates the csu shelf associated with the ncmdsu port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmcsuslot 3.1.3022.2001.1.7
This variable indicates the csu slot associated with the ncmdsu port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdsuAlarmEnable 3.1.3022.2001.1.8
This variable indicates whether the alarm is enabled or disabled for ncmdsu.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nO(1), yES(2)  

ncmdsuLosLead 3.1.3022.2001.1.9
This variable indicates the DTE lead bits for port. The DTE leads can be set by setting the relevant bit to 1 and reset by setting the relevant bit to zero. Bit Value Name Description 0 set the ncmdsu port configuration to zero 0 1 DTR set uses DTR 1 2 RTS set uses RTS 2 4 DSR set uses DSR 3 8 CTS set uses CTS 4 16 DCD set uses DCD 5 32 LOS use both bits: bits set to use for alarm 6 64 LOS 0 = Disable LOS detect, 1=use RTS , 2 = DTR 7 128 DDSMode set for 56k DDS .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdsuTimingSource 3.1.3022.2001.1.10
This variable indicates the T1 timing source for ncmdsu.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), port1(2), port2(3), cSU(4)  

ncmdsuDTESpeed 3.1.3022.2001.1.11
This variable indicates DTE Speed control and speeds 38.4k or below holds good for the DIU2131 card type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), mode-64k(2), mode-56k(3), mode-38-4(4), mode-19-2(5), mode-9-6(6), mode-4-8(7), mode-2-4(8)  

ncmdsustatTable 3.1.3022.2003
The ncm dsu stat table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NcmdsustatEntry

ncmdsustatEntry 3.1.3022.2003.1
An entry in the ncm dsu stat table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NcmdsustatEntry  

ncmdsuNIDstatIndex 3.1.3022.2003.1.1
This object specifies the node id of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsustatIndex 3.1.3022.2003.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsuPortLowbattery 3.1.3022.2003.1.3
The ncmdsu Lowbattery status for Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER not-low-battery(1), low-battery(2)  

ncmdsuPortLOSstatus 3.1.3022.2003.1.4
The ncmdsu LOS status for Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER not-Los-status(1), los-status(2)  

ncmdsuPortblockerrorcounter 3.1.3022.2003.1.5
The number of block errors produced on port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmdsuPortTestSeconds 3.1.3022.2003.1.6
The number of errors produced by a test on port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmdsuPortrateper8000 3.1.3022.2003.1.7
The rate/8000 on port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsuPortLeadStatus1 3.1.3022.2003.1.8
This variable indicates the Lead Status (part 1) of the port. The various bit positions are: Bit Value Name 0 1 DTR (1 = on; 0 = off) 1 2 RTS 2 4 DSR 3 8 CTS 4 16 DCD 5 32 TXD 6 64 RXD 7 128 Lead status available bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsuPortLeadStatus2 3.1.3022.2003.1.9
This variable indicates the Lead Status (part 2) of the port.The lead status2 is bit mapped. The various bit positions are: BIT Value Name 0 0 no-loop 0 1 local-loop 1 2 remote-loop 2 4 test-mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdbuPrimaryLineStatus 3.1.3022.2003.1.10
This variable indicates the Primary Line Status of the ncmdbu.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oK(1), aSC(2), lOF(3), cD(4), uSER(5), yEL(6), bER(7), aLLONE(8), lOS(9)  

ncmdbuLineStatus 3.1.3022.2003.1.11
This variable indicates the ncmdbu Line Status of the ncmdbu.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sTANDBY(1), aCTIVE(2), eRROR(3)  

ncmdbuSwitchBy 3.1.3022.2003.1.12
This variable indicates the cause of the ncmdbu switching.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER nONE(1), aSC(2), lOF(3), cD(4), uSER(5), yEL(6), bER(7), aLLONE(8), lOS(9)  

ncmdbuReceivedCode 3.1.3022.2003.1.13
This variable indicates the ncmdbu received code in hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsuPortTestResults 3.1.3022.2003.1.14
The number of errors produced by a test on port .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdsuPortDiagStatus 3.1.3022.2003.1.15
This variable indicates the Diagnostic Status of the port. The various bit positions are: Bit Value Name 0 1 Reserved 1 2 Reserved 2 4 Reserved 3 8 Sending Test Code 4 16 Sending loopdown code 5 32 Sending loopup code 6 64 far end looped 7 128 Near end looped.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmddsMainConfigTable 3.1.3024.5000
The ncmdds Main Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NcmddsMainConfigEntry

ncmddsMainConfigEntry 3.1.3024.5000.1
An entry in the ncmdds Main Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NcmddsMainConfigEntry  

ncmddsNIDMainConfigIndex 3.1.3024.5000.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmddsMainLineIndex 3.1.3024.5000.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmddsdsubus 3.1.3024.5000.1.3
The ncmdsu bus type for Port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), busA(2), busB(3), busC(4)  

ncmddsPortChannel 3.1.3024.5000.1.4
This variable indicates the channel assignment for the ncmdsu for the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

ncmddsPortConfiguration 3.1.3024.5000.1.5
This variable indicates the configuration bits for port. The configuration can be set by setting the relevant bit to 1 and reset by setting the relevant bit to zero. Bit Value Name Description 0 set the ncmdsu port configuration to zero 0 1 64k set uses 8bits of data/64kbps. 1 2 LEN set enable loop code and loop commands 2 4 INV set invert the channelized data 3 8 SCR set to scramble channelized data. 4 16 CLK1 DTE transmit clock select bits 5 32 CLK2 DTE transmit clock select bits 6 64 TU set port as a timing unit 7 128 ALM set if DIU has to report alarms to SAM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddscsushelf 3.1.3024.5000.1.6
This variable indicates the csu shelf associated with the ncmdsu port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddscsuslot 3.1.3024.5000.1.7
This variable indicates the csu slot associated with the ncmdsu port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsLosLead 3.1.3024.5000.1.8
This variable indicates the DTE lead bits for port. The DTE leads can be set by setting the relevant bit to 1 and reset by setting the relevant bit to zero. Bit Value Name Description 0 set the ncmdsu port configuration to zero 0 1 DTR set uses DTR 1 2 RTS set uses RTS 2 4 DSR set uses DSR 3 8 CTS set uses CTS 4 16 DCD set uses DCD 5 32 LOS use both bits: bits set to use for alarm 6 64 LOS 0 = Disable LOS detect, 1=use RTS , 2 = DTR 7 128 DDSMode set for 56k DDS .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsConfigTable 3.1.3024.5001
The ncmdds Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NcmddsConfigEntry

ncmddsConfigEntry 3.1.3024.5001.1
An entry in the ncmdds Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NcmddsConfigEntry  

ncmddsNIDConfigIndex 3.1.3024.5001.1.1
This variable specifies the node id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmddsConfigLineIndex 3.1.3024.5001.1.2
This variable specifies the Line index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmddsPortLoopEnable 3.1.3024.5001.1.3
This variable indicates the loop enable bits for port. The loop enable can be set by setting the relevant bit to 1 and reset by setting the relevant bit to zero. Bit Value Description 0 no-loop 0 1 enable ncmdds loop 1 2 enable v54 loop 2 4 enable ft1 loop 3 8 enable verilink loop 4 16 5 32 6 64 7 128 .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

ncmddsPortReceiveLoopCode 3.1.3024.5001.1.4
This variable indicates the Receive ncmdds loop code of the port 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dSU(1), channel(2)  

ncmddsPortRemoteLoopCode 3.1.3024.5001.1.5
This variable indicates the Receive ncmdds loop code of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v54(1), fTI(2), verilink(3)  

ncmddsPortAlarmEnable 3.1.3024.5001.1.6
This variable indicates the Alarm enable which is bit mapped of the port. BIT Value Description 0 0 no-loop 0 1 alarm-on-loop 1 2 alarm-on-test 3 both
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

ncmddsPortAlarmClearDelayTime 3.1.3024.5001.1.7
This variable indicates the Alarmcleardelaytime of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsPortAbnormalStationCodeThreshold 3.1.3024.5001.1.8
This variable indicates the AbnormalStationCodethreshold of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsPortControlModeIdleThreshold 3.1.3024.5001.1.9
This variable indicates the ControlModeIdlethreshold of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsPortMuxOutofSyncThreshold 3.1.3024.5001.1.10
This variable indicates the MuxoutofSyncthreshold of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsPortUnAssignedMuxChannelThreshold 3.1.3024.5001.1.11
This variable indicates the UnassignedMuxChannelthreshold of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsPortGroup1Codes 3.1.3024.5001.1.12
This variable indicates the port1Group1ncmddsCodes of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmddsPort56KStatus 3.1.3024.5001.1.13
This variable indicates the 56K ncmdds Status of the port. The various bit positions are: 0 Abnormal Station code(1 = Yes, 0 = No) 1 Control Mode Idle 2 Mux-Out-of-Sync 3 Unassigned Mux Chan 4 Group 1 ncmdds Codes Test Test 5 Test in Progress { 0 } Verilink {0} 511 6 Test in Progress { 0 } {1} 7 ncmdds mode enabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmddsPortReceived56KCode 3.1.3024.5001.1.14
This variable specifies the received 56K ncmdds code.Some specitic values indicate the specific testing error. Value Testing Error 1 UMC 2 TIP 3 TA 4 MA 5 RC 6 BL 7 LBE 8 FEV 9 ASC 10 OOS 11 CMI 12 TC
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER umc(1), tip(2), ta(3), ma(4), rc(5), bl(6), lbe(7), fev(8), asc(9), oos(10), cmi(11), tc(12)  

ncmddsmode 3.1.3024.5001.1.15
This variable specifies the mode of ncmdds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mode-56k(1), mode-64k(2), mode-56kncmdds(3)  

ncmddsLatchingLoopbackType 3.1.3024.5001.1.16
This variable specifies the latching loop up type of dds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER chan-loop-up(1), dsu-loop-up(2), ocu-loop-up(3), chan-loop-dn(4), none(5)  

ncmddsLatchingLoopbackDevNo 3.1.3024.5001.1.17
This variable specifies the device number to receive code. Range is 0 to 7, where 0 is the first device. Used only for DS0-Data Port loopback option of Latching Loopback Type Object. No signifiance right now.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdbuMainConfigTable 3.1.3023.4000
The ncm dbu Main Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NcmdbuMainConfigEntry

ncmdbuMainConfigEntry 3.1.3023.4000.1
An entry in the ncm dbu Main Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NcmdbuMainConfigEntry  

ncmdbuNIDMainConfigIndex 3.1.3023.4000.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmdbuMainLineIndex 3.1.3023.4000.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdbudsubus 3.1.3023.4000.1.3
The ncmdsu bus type for Port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), busA(2), busB(3), busC(4)  

ncmdbuPortChannel 3.1.3023.4000.1.4
This variable indicates the channel assignment for the ncmdbu for the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

ncmdbuPortConfiguration 3.1.3023.4000.1.5
This variable indicates the configuration bits for port. The configuration can be set by setting the relevant bit to 1 and reset by setting the relevant bit to zero. Bit Value Name Description 0 set the ncmdsu port configuration to zero 0 1 64k set uses 8bits of data/64kbps. 1 2 LEN set enable loop code and loop commands 2 4 INV set invert the channelized data 3 8 SCR set to scramble channelized data. 4 16 CLK1 DTE transmit clock select bits 5 32 CLK2 DTE transmit clock select bits 6 64 TU set port as a timing unit 7 128 ALM set if DIU has to report alarms to SAM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdbucsushelf 3.1.3023.4000.1.6
This variable indicates the csu shelf associated with the ncmdbu port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdbucsuslot 3.1.3023.4000.1.7
This variable indicates the csu slot associated with the ncmdbu port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdbuLosLead 3.1.3023.4000.1.8
This variable indicates the DTE lead bits for port. The DTE leads can be set by setting the relevant bit to 1 and reset by setting the relevant bit to zero. Bit Value Name Description 0 set the ncmdsu port configuration to zero 0 1 DTR set uses DTR 1 2 RTS set uses RTS 2 4 DSR set uses DSR 3 8 CTS set uses CTS 4 16 DCD set uses DCD 5 32 LOS use both bits: bits set to use for alarm 6 64 LOS 0 = Disable LOS detect, 1=use RTS , 2 = DTR 7 128 DDSMode set for 56k DDS .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdbuConfigTable 3.1.3023.4001
The ncm dbu Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NcmdbuConfigEntry

ncmdbuConfigEntry 3.1.3023.4001.1
An entry in the ncmdbu Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NcmdbuConfigEntry  

ncmdbuNIDConfigIndex 3.1.3023.4001.1.1
This variable specifies the node id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdbuLineIndex 3.1.3023.4001.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ncmdbuAllOnesSwitchOverTime 3.1.3023.4001.1.3
This variable indicates the all ones duration in seconds for the ncmdbu.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ncmdbuSwitchOnBERThresholdExceeded 3.1.3023.4001.1.4
This variable indicates whether the ncmdbu is switched on for BER Threshold exceeded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nO(1), yES(2)  

ncmdbuDialBackupMode 3.1.3023.4001.1.5
This variable indicates the dial backup mode for the ncmdbu.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manual-manual(1), automatic-automatic(2), automatic-manual(3)  

ncmdbuBackupConnection 3.1.3023.4001.1.6
This variable indicates the whether the backup connection is activated or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), deactivate(2), activate(3)  

ncmdbumode 3.1.3023.4001.1.7
This variable specifies the mode of ncmdbu.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mode-56k(1), mode-64k(2), mode-56kncmdds(3)  

ncmdbuLoopType 3.1.3023.4001.1.8
This variable specifies the Loop Type on RL EIA .
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fT1(1)