WebGraph-Thermo-Hygrometer-US-MIB

File: WebGraph-Thermo-Hygrometer-US-MIB.mib (73008 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
PhysAddress enterprises TimeTicks
IpAddress NetworkAddress

Defined Types

WtWebGraphThermHygroSensorEntry  
SEQUENCE    
  wtWebGraphThermHygroSensorNo INTEGER

WtWebGraphThermHygroTempValueEntry  
SEQUENCE    
  wtWebGraphThermHygroTempValue OCTET STRING

WtWebGraphThermHygroBinaryTempValueEntry  
SEQUENCE    
  wtWebGraphThermHygroBinaryTempValue INTEGER

WtWebGraphThermHygroSensorColorEntry  
SEQUENCE    
  wtWebGraphThermHygroSensorColor OCTET STRING

WtWebGraphThermHygroAlarmIfEntry  
SEQUENCE    
  wtWebGraphThermHygroAlarmNo INTEGER

WtWebGraphThermHygroAlarmEntry  
SEQUENCE    
  wtWebGraphThermHygroAlarmTrigger OCTET STRING
  wtWebGraphThermHygroAlarmMin OCTET STRING
  wtWebGraphThermHygroAlarmMax OCTET STRING
  wtWebGraphThermHygroAlarmHysteresis OCTET STRING
  wtWebGraphThermHygroAlarmDelay OCTET STRING
  wtWebGraphThermHygroAlarmInterval OCTET STRING
  wtWebGraphThermHygroAlarmEnable OCTET STRING
  wtWebGraphThermHygroAlarmEMailAddr OCTET STRING
  wtWebGraphThermHygroAlarmMailSubject OCTET STRING
  wtWebGraphThermHygroAlarmMailText OCTET STRING
  wtWebGraphThermHygroAlarmManagerIP OCTET STRING
  wtWebGraphThermHygroAlarmTrapText OCTET STRING
  wtWebGraphThermHygroAlarmMailOptions OCTET STRING
  wtWebGraphThermHygroAlarmTcpIpAddr OCTET STRING
  wtWebGraphThermHygroAlarmTcpPort INTEGER
  wtWebGraphThermHygroAlarmTcpText OCTET STRING
  wtWebGraphThermHygroAlarmClearMailSubject OCTET STRING
  wtWebGraphThermHygroAlarmClearMailText OCTET STRING
  wtWebGraphThermHygroAlarmClearTrapText OCTET STRING
  wtWebGraphThermHygroAlarmClearTcpText OCTET STRING
  wtWebGraphThermHygroAlarmDeltaTemp OCTET STRING
  wtWebGraphThermHygroAlarmRHMin OCTET STRING
  wtWebGraphThermHygroAlarmRHMax OCTET STRING
  wtWebGraphThermHygroAlarmRHHysteresis OCTET STRING
  wtWebGraphThermHygroAlarmAHMin OCTET STRING
  wtWebGraphThermHygroAlarmAHMax OCTET STRING
  wtWebGraphThermHygroAlarmSyslogIpAddr OCTET STRING
  wtWebGraphThermHygroAlarmSyslogPort INTEGER
  wtWebGraphThermHygroAlarmSyslogText OCTET STRING
  wtWebGraphThermHygroAlarmSyslogClearText OCTET STRING
  wtWebGraphThermHygroAlarmFtpDataPort OCTET STRING
  wtWebGraphThermHygroAlarmFtpFileName OCTET STRING
  wtWebGraphThermHygroAlarmFtpText OCTET STRING
  wtWebGraphThermHygroAlarmFtpClearText OCTET STRING
  wtWebGraphThermHygroAlarmFtpOption OCTET STRING
  wtWebGraphThermHygroAlarmTimerCron OCTET STRING

WtWebGraphThermHygroPortEntry  
SEQUENCE    
  wtWebGraphThermHygroPortName OCTET STRING
  wtWebGraphThermHygroPortText OCTET STRING
  wtWebGraphThermHygroPortOffset1 OCTET STRING
  wtWebGraphThermHygroPortTemperature1 OCTET STRING
  wtWebGraphThermHygroPortOffset2 OCTET STRING
  wtWebGraphThermHygroPortTemperature2 OCTET STRING
  wtWebGraphThermHygroPortComment OCTET STRING

Defined Values

wut 1.3.6.1.4.1.5040
OBJECT IDENTIFIER    

wtComServer 1.3.6.1.4.1.5040.1
OBJECT IDENTIFIER    

wtWebio 1.3.6.1.4.1.5040.1.2
OBJECT IDENTIFIER    

wtWebGraphThermHygro 1.3.6.1.4.1.5040.1.2.9
OBJECT IDENTIFIER    

wtWebGraphThermHygroTemp 1.3.6.1.4.1.5040.1.2.9.1
OBJECT IDENTIFIER    

wtWebGraphThermHygroSessCntrl 1.3.6.1.4.1.5040.1.2.9.2
OBJECT IDENTIFIER    

wtWebGraphThermHygroConfig 1.3.6.1.4.1.5040.1.2.9.3
OBJECT IDENTIFIER    

wtWebGraphThermHygroDiag 1.3.6.1.4.1.5040.1.2.9.4
OBJECT IDENTIFIER    

wtWebGraphThermHygroDevice 1.3.6.1.4.1.5040.1.2.9.3.1
OBJECT IDENTIFIER    

wtWebGraphThermHygroPorts 1.3.6.1.4.1.5040.1.2.9.3.2
OBJECT IDENTIFIER    

wtWebGraphThermHygroManufact 1.3.6.1.4.1.5040.1.2.9.3.3
OBJECT IDENTIFIER    

wtWebGraphThermHygroText 1.3.6.1.4.1.5040.1.2.9.3.1.1
OBJECT IDENTIFIER    

wtWebGraphThermHygroTimeDate 1.3.6.1.4.1.5040.1.2.9.3.1.2
OBJECT IDENTIFIER    

wtWebGraphThermHygroBasic 1.3.6.1.4.1.5040.1.2.9.3.1.3
OBJECT IDENTIFIER    

wtWebGraphThermHygroDatalogger 1.3.6.1.4.1.5040.1.2.9.3.1.4
OBJECT IDENTIFIER    

wtWebGraphThermHygroAlarm 1.3.6.1.4.1.5040.1.2.9.3.1.5
OBJECT IDENTIFIER    

wtWebGraphThermHygroTimeZone 1.3.6.1.4.1.5040.1.2.9.3.1.2.1
OBJECT IDENTIFIER    

wtWebGraphThermHygroTimeServer 1.3.6.1.4.1.5040.1.2.9.3.1.2.2
OBJECT IDENTIFIER    

wtWebGraphThermHygroDeviceClock 1.3.6.1.4.1.5040.1.2.9.3.1.2.3
OBJECT IDENTIFIER    

wtWebGraphThermHygroNetwork 1.3.6.1.4.1.5040.1.2.9.3.1.3.1
OBJECT IDENTIFIER    

wtWebGraphThermHygroHTTP 1.3.6.1.4.1.5040.1.2.9.3.1.3.2
OBJECT IDENTIFIER    

wtWebGraphThermHygroMail 1.3.6.1.4.1.5040.1.2.9.3.1.3.3
OBJECT IDENTIFIER    

wtWebGraphThermHygroSNMP 1.3.6.1.4.1.5040.1.2.9.3.1.3.4
OBJECT IDENTIFIER    

wtWebGraphThermHygroUDP 1.3.6.1.4.1.5040.1.2.9.3.1.3.5
OBJECT IDENTIFIER    

wtWebGraphThermHygroSyslog 1.3.6.1.4.1.5040.1.2.9.3.1.3.6
OBJECT IDENTIFIER    

wtWebGraphThermHygroFTP 1.3.6.1.4.1.5040.1.2.9.3.1.3.7
OBJECT IDENTIFIER    

wtWebGraphThermHygroSensors 1.3.6.1.4.1.5040.1.2.9.1.1
Number of sensors
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebGraphThermHygroSensorTable 1.3.6.1.4.1.5040.1.2.9.1.2
List of sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermHygroSensorEntry

wtWebGraphThermHygroSensorEntry 1.3.6.1.4.1.5040.1.2.9.1.2.1
List of sensor numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermHygroSensorEntry  

wtWebGraphThermHygroSensorNo 1.3.6.1.4.1.5040.1.2.9.1.2.1.1
Sensor number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebGraphThermHygroTempValueTable 1.3.6.1.4.1.5040.1.2.9.1.3
List of measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermHygroTempValueEntry

wtWebGraphThermHygroTempValueEntry 1.3.6.1.4.1.5040.1.2.9.1.3.1
Measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermHygroTempValueEntry  

wtWebGraphThermHygroTempValue 1.3.6.1.4.1.5040.1.2.9.1.3.1.1
Measurement value of the sensor, ASCII, 5 characters in length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebGraphThermHygroBinaryTempValueTable 1.3.6.1.4.1.5040.1.2.9.1.4
List of binary measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermHygroBinaryTempValueEntry

wtWebGraphThermHygroBinaryTempValueEntry 1.3.6.1.4.1.5040.1.2.9.1.4.1
Binary measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermHygroBinaryTempValueEntry  

wtWebGraphThermHygroBinaryTempValue 1.3.6.1.4.1.5040.1.2.9.1.4.1.1
Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroSessCntrlPassword 1.3.6.1.4.1.5040.1.2.9.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebGraphThermHygroSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.9.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroSessCntrl-NoSession(0), wtWebGraphThermHygroSessCntrl-Session(1)  

wtWebGraphThermHygroSessCntrlLogout 1.3.6.1.4.1.5040.1.2.9.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.9.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.9.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDeviceName 1.3.6.1.4.1.5040.1.2.9.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDeviceText 1.3.6.1.4.1.5040.1.2.9.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDeviceLocation 1.3.6.1.4.1.5040.1.2.9.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDeviceContact 1.3.6.1.4.1.5040.1.2.9.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroTzOffsetHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroTzOffsetMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroTzEnable 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroStTzOffsetMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroStTzEnable 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroStTzStartMonth 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroStartMonth-January(1), wtWebGraphThermHygroStartMonth-February(2), wtWebGraphThermHygroStartMonth-March(3), wtWebGraphThermHygroStartMonth-April(4), wtWebGraphThermHygroStartMonth-May(5), wtWebGraphThermHygroStartMonth-June(6), wtWebGraphThermHygroStartMonth-July(7), wtWebGraphThermHygroStartMonth-August(8), wtWebGraphThermHygroStartMonth-September(9), wtWebGraphThermHygroStartMonth-October(10), wtWebGraphThermHygroStartMonth-November(11), wtWebGraphThermHygroStartMonth-December(12)  

wtWebGraphThermHygroStTzStartMode 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroStartMode-first(1), wtWebGraphThermHygroStartMode-second(2), wtWebGraphThermHygroStartMode-third(3), wtWebGraphThermHygroStartMode-fourth(4), wtWebGraphThermHygroStartMode-last(5)  

wtWebGraphThermHygroStTzStartWday 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroStartWday-Sunday(1), wtWebGraphThermHygroStartWday-Monday(2), wtWebGraphThermHygroStartWday-Tuesday(3), wtWebGraphThermHygroStartWday-Thursday(4), wtWebGraphThermHygroStartWday-Wednesday(5), wtWebGraphThermHygroStartWday-Friday(6), wtWebGraphThermHygroStartWday-Saturday(7)  

wtWebGraphThermHygroStTzStartHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroStTzStartMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroStTzStopMonth 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroStopMonth-January(1), wtWebGraphThermHygroStopMonth-February(2), wtWebGraphThermHygroStopMonth-March(3), wtWebGraphThermHygroStopMonth-April(4), wtWebGraphThermHygroStopMonth-May(5), wtWebGraphThermHygroStopMonth-June(6), wtWebGraphThermHygroStopMonth-July(7), wtWebGraphThermHygroStopMonth-August(8), wtWebGraphThermHygroStopMonth-September(9), wtWebGraphThermHygroStopMonth-October(10), wtWebGraphThermHygroStopMonth-November(11), wtWebGraphThermHygroStopMonth-December(12)  

wtWebGraphThermHygroStTzStopMode 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroStopMode-first(1), wtWebGraphThermHygroStopMode-second(2), wtWebGraphThermHygroStopMode-third(3), wtWebGraphThermHygroStopMode-fourth(4), wtWebGraphThermHygroStopMode-last(5)  

wtWebGraphThermHygroStTzStopWday 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroStopWday-Sunday(1), wtWebGraphThermHygroStopWday-Monday(2), wtWebGraphThermHygroStopWday-Tuesday(3), wtWebGraphThermHygroStopWday-Thursday(4), wtWebGraphThermHygroStopWday-Wednesday(5), wtWebGraphThermHygroStopWday-Friday(6), wtWebGraphThermHygroStopWday-Saturday(7)  

wtWebGraphThermHygroStTzStopHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroStTzStopMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroTimeServer1 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroTimeServer2 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroTsEnable 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroTsSyncTime 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroClockHrs 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebGraphThermHygroClockMin 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebGraphThermHygroClockDay 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebGraphThermHygroClockMonth 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroClockMonth-January(1), wtWebGraphThermHygroClockMonth-February(2), wtWebGraphThermHygroClockMonth-March(3), wtWebGraphThermHygroClockMonth-April(4), wtWebGraphThermHygroClockMonth-May(5), wtWebGraphThermHygroClockMonth-June(6), wtWebGraphThermHygroClockMonth-July(7), wtWebGraphThermHygroClockMonth-August(8), wtWebGraphThermHygroClockMonth-September(9), wtWebGraphThermHygroClockMonth-October(10), wtWebGraphThermHygroClockMonth-November(11), wtWebGraphThermHygroClockMonth-December(12)  

wtWebGraphThermHygroClockYear 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebGraphThermHygroIpAddress 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermHygroSubnetMask 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermHygroGateway 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermHygroDnsServer1 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDnsServer2 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAddConfig 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroStartup 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.1
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroGetHeaderEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.2
If this bit is set, every answer of a short form GET question will be lead by the IP-address and name of the device: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroHttpPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermHygroMailAdName 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMailReply 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMailServer 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1MailEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMailAuthentication 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroMailAuthUser 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMailAuthPassword 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMailPop3Server 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.1
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.2
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.3
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSystemTrapEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.4
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroSnmpEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.6
Community string send within traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroUdpPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermHygroUdpEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSyslogServerIP 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroSyslogServerPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroSyslogEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroFTPServerIP 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroFTPServerControlPort 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroFTPUserName 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroFTPPassword 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroFTPAccount 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroFTPOption 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroFTPEnable 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroLoggerTimebase 1.3.6.1.4.1.5040.1.2.9.3.1.4.1
Time base of the data logger
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroDatalogger-1Min(1), wtWebGraphThermHygroDatalogger-5Min(2), wtWebGraphThermHygroDatalogger-15Min(3), wtWebGraphThermHygroDatalogger-60Min(4)  

wtWebGraphThermHygroLoggerSensorSel 1.3.6.1.4.1.5040.1.2.9.3.1.4.2
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroDisplaySensorSel 1.3.6.1.4.1.5040.1.2.9.3.1.4.3
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroSensorColorTable 1.3.6.1.4.1.5040.1.2.9.3.1.4.4
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermHygroSensorColorEntry

wtWebGraphThermHygroSensorColorEntry 1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1
Index numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermHygroSensorColorEntry  

wtWebGraphThermHygroSensorColor 1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebGraphThermHygroAutoScaleEnable 1.3.6.1.4.1.5040.1.2.9.3.1.4.5
If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroVerticalUpperLimit 1.3.6.1.4.1.5040.1.2.9.3.1.4.6
This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroVerticalLowerLimit 1.3.6.1.4.1.5040.1.2.9.3.1.4.7
This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroHorizontalZoom 1.3.6.1.4.1.5040.1.2.9.3.1.4.8
Defines the default zoom stage, if no auto scaling is selected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermHygroZoom-25min(1), wtWebGraphThermHygroZoom-75min(2), wtWebGraphThermHygroZoom-5hrs(3), wtWebGraphThermHygroZoom-30hrs(4), wtWebGraphThermHygroZoom-5days(5), wtWebGraphThermHygroZoom-25days(6)  

wtWebGraphThermHygroAlarmCount 1.3.6.1.4.1.5040.1.2.9.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebGraphThermHygroAlarmIfTable 1.3.6.1.4.1.5040.1.2.9.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermHygroAlarmIfEntry

wtWebGraphThermHygroAlarmIfEntry 1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermHygroAlarmIfEntry  

wtWebGraphThermHygroAlarmNo 1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1.1
Alarm number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebGraphThermHygroAlarmTable 1.3.6.1.4.1.5040.1.2.9.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermHygroAlarmEntry

wtWebGraphThermHygroAlarmEntry 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermHygroAlarmEntry  

wtWebGraphThermHygroAlarmTrigger 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.1
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroAlarmMin 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.2
Minimum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmMax 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.3
Maximum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmHysteresis 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.4
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmDelay 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.5
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmInterval 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.6
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmEnable 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.7
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroAlarmEMailAddr 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmMailSubject 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.9
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmMailText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.10
Alarm mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmManagerIP 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.11
Name or IP address of the SNMP Manager which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmTrapText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.12
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmMailOptions 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.13
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.14
Name or IP address of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmTcpPort 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15
Port number of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermHygroAlarmTcpText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.16
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.17
Subject line for alarm clear mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmClearMailText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.18
Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmClearTrapText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.19
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmClearTcpText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.20
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmDeltaTemp 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.21
Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmRHMin 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.22
Minimum rel. Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmRHMax 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.23
Maximum rel.Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmRHHysteresis 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.24
Hysterese rel. Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmAHMin 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.25
Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmAHMax 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.26
Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.27
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermHygroAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermHygroAlarmSyslogText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.29
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.31
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.32
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmFtpText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.33
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmFtpClearText 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.34
Alarm clear message to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroAlarmFtpOptions 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.35
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroAlarmTimerCron 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.36
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortTable 1.3.6.1.4.1.5040.1.2.9.3.2.1
List of settings depending on the sensor number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermHygroPortEntry

wtWebGraphThermHygroPortEntry 1.3.6.1.4.1.5040.1.2.9.3.2.1.1
Sensor parameters for the individual sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermHygroPortEntry  

wtWebGraphThermHygroPortName 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.1
Name of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortText 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.2
Description of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortOffset1 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.3
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortTemperature1 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.4
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortOffset2 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.5
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortTemperature2 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.6
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortComment 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.7
Offset calibration: informations of date, name of operator, reference devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroPortSensorSelect 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8
Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: unused Binary coded options for sensor 2: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : W&T Sensor rel. humidity (default) Bit 1 : Skalar 0-2.5V Bit 2 : Disconnect Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermHygroMfName 1.3.6.1.4.1.5040.1.2.9.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMfAddr 1.3.6.1.4.1.5040.1.2.9.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMfHotline 1.3.6.1.4.1.5040.1.2.9.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMfInternet 1.3.6.1.4.1.5040.1.2.9.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMfDeviceTyp 1.3.6.1.4.1.5040.1.2.9.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroMfOrderNo 1.3.6.1.4.1.5040.1.2.9.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDiagErrorCount 1.3.6.1.4.1.5040.1.2.9.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroDiagBinaryError 1.3.6.1.4.1.5040.1.2.9.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDiagErrorIndex 1.3.6.1.4.1.5040.1.2.9.4.3
The value of this variable is used as an index to read an error massege from wtWebGraphThermHygroDiagErrorMessage. Errors are numbered from 1 to wtWebGraphThermHygroDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphThermHygroDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroDiagErrorMessage 1.3.6.1.4.1.5040.1.2.9.4.4
Using wtWebGraphThermHygroDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermHygroDiagErrorClear 1.3.6.1.4.1.5040.1.2.9.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermHygroAlert1 31
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert2 32
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert3 33
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert4 34
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert5 35
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert6 36
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert7 37
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert8 38
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert9 91
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert10 92
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert11 93
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert12 94
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert13 95
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert14 96
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert15 97
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlert16 98
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermHygroAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE