Wellfleet-DSUCSU-MIB

File: Wellfleet-DSUCSU-MIB.mib (12826 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 Wellfleet-COMMON-MIB

Imported symbols

Counter OBJECT-TYPE DisplayString
TRAP-TYPE wfDsuCsuGroup

Defined Types

WfDsuCsuIfEntry  
SEQUENCE    
  wfDsuCsuIfDelete INTEGER
  wfDsuCsuIfSlot INTEGER
  wfDsuCsuIfConnector INTEGER
  wfDsuCsuSoftRev DisplayString
  wfDsuCsuHardRev DisplayString
  wfDsuCsuOpMode INTEGER
  wfDsuCsuTxClkSelect INTEGER
  wfDsuCsuUnitReset INTEGER
  wfDsuCsu64KTxMonitor INTEGER
  wfDsuCsuOpState INTEGER
  wfDsuCsuServiceStatus INTEGER
  wfDsuCsuV54Lpbk INTEGER
  wfDsuCsuV54Timer INTEGER
  wfDsuCsuV54Errors Counter
  wfDsuCsuCqmsLaWindow INTEGER
  wfDsuCsuCqmsLaErrors Counter
  wfDsuCsuCqmsLaPollRate INTEGER
  wfDsuCsuCqmsReset INTEGER
  wfDsuCsuOOSErrors Counter
  wfDsuCsuFrameErrors Counter
  wfDsuCsuLOLErrors Counter
  wfDsuCsuInitState INTEGER

Defined Values

wfDsuCsuIfTable 1.3.6.1.4.1.18.3.4.30.1
DSU CSU line record.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsuCsuIfEntry

wfDsuCsuIfEntry 1.3.6.1.4.1.18.3.4.30.1.1
An entry in the DSU CSU IF table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsuCsuIfEntry  

wfDsuCsuIfDelete 1.3.6.1.4.1.18.3.4.30.1.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfDsuCsuIfSlot 1.3.6.1.4.1.18.3.4.30.1.1.2
Instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsuCsuIfConnector 1.3.6.1.4.1.18.3.4.30.1.1.3
Instance ID Connector, filled in by the driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsuCsuSoftRev 1.3.6.1.4.1.18.3.4.30.1.1.4
Displays the Software Revision of the DSU CSU card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

wfDsuCsuHardRev 1.3.6.1.4.1.18.3.4.30.1.1.5
Displays the Hardware Revision of the DSU CSU card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

wfDsuCsuOpMode 1.3.6.1.4.1.18.3.4.30.1.1.6
Identifies the type of telco service that the DSU CSU is connected to. Opmode should be set to dds1-56kbps (1) when connected to a DDS1 56 Kbps line. Opmode should be set to cc-64kbps (2) when connected to a Clear Channel 64Kbps line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dds156kbps(1), cc64kbps(2)  

wfDsuCsuTxClkSelect 1.3.6.1.4.1.18.3.4.30.1.1.7
Default timing, or clock, source for transmiting data to the network. There must be only one source on a DDS line. Timing should always be slave (1) when connected to a network. Timing should be set to master (2) on either end of a private-wire configuration, with the other end being set to slave (1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slave(1), master(2)  

wfDsuCsuUnitReset 1.3.6.1.4.1.18.3.4.30.1.1.8
Enables the operator to remotely reset the unit. Using this command will cause the unit to terminate all its connections and drop data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER resetUnit(1)  

wfDsuCsu64KTxMonitor 1.3.6.1.4.1.18.3.4.30.1.1.9
This signal is used in 64K Clear Channel mode to suppress customer data in the event that the data duplicates a network control code. A setting of enabled(1) suppresses customer data. A setting of disabled(2) allows all customer data through, which could potentially put the other end into a loop if the data duplicates a network control code.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfDsuCsuOpState 1.3.6.1.4.1.18.3.4.30.1.1.10
Indicates the current operating state of the DSU CSU card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), localLpbk(2), digitalLpbk(3), remDigitalLpbk(4), telcoLpbk(5), remDigLpbkWPattern(6), localAnlgLpbkWPattern(7), pattern2047Gen(8)  

wfDsuCsuServiceStatus 1.3.6.1.4.1.18.3.4.30.1.1.11
The Current status of the physical interface. Your network carrier can send Out-of-Service or Maintenance Mode codes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inService(1), outOfService(2), frameError(3), lossOfLine(5), telcoLpbk(6)  

wfDsuCsuV54Lpbk 1.3.6.1.4.1.18.3.4.30.1.1.12
Enables the operator to control, and examine the state of, V.54 loopbacks within the DSU CSU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noLoop(1), localAnlgLpbk(2), localDigLpbk(3), remDigLpbk(4), remDigLpbkWPattern(5), localAnlgLpbkWPattern(6), pattern2047Gen(7)  

wfDsuCsuV54Timer 1.3.6.1.4.1.18.3.4.30.1.1.13
Duration in seconds that a test specified in wfDsuCsuTestLpbk is to execute.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wfDsuCsuV54Errors 1.3.6.1.4.1.18.3.4.30.1.1.14
Indicates the number of errors reported during the last loopback test. This count will only be updated for loopbacks with test pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDsuCsuCqmsLaWindow 1.3.6.1.4.1.18.3.4.30.1.1.15
Indicates the number of minutes within the window in which the availability of the line (network) is to be calculated. The availability of the line is an indication of the percentage of time the line has been in service. It is calculated as follows: (((wfDsuCsuCqmsLaWindow*60) - (wfDsuCsuCqmsLaErrCnt*wfDsuCsuCqmsLaPollRate))/ wfDsuCsuCqmsLaWindow*60)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

wfDsuCsuCqmsLaErrors 1.3.6.1.4.1.18.3.4.30.1.1.16
Indicates the total number of seconds that the line was not in service in the last window of size wfDsuCsuCqmsLaWindow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDsuCsuCqmsLaPollRate 1.3.6.1.4.1.18.3.4.30.1.1.17
Indicates the number of seconds between polls for line status from the DsuCsu. A value of 1 forces polling every second. A value of 60 forces polling every minute.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

wfDsuCsuCqmsReset 1.3.6.1.4.1.18.3.4.30.1.1.18
Resets the CQMS counters to their default values. For Line Availability, wfDsuCsuCqmsLaErrCnt is reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER resetCqms(1)  

wfDsuCsuOOSErrors 1.3.6.1.4.1.18.3.4.30.1.1.19
The number of seconds in which Out of Service control codes were received from the Telco. The counter is incremented whenever a sample within a second indicated the unit received an out of service control code.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDsuCsuFrameErrors 1.3.6.1.4.1.18.3.4.30.1.1.20
The number of seconds in which the unit was out of frame with the Telco. This is only applicable in 64K mode. The counter is incremented whenever a sample within a second indicated the unit was out of frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDsuCsuLOLErrors 1.3.6.1.4.1.18.3.4.30.1.1.21
The number of seconds in which the unit has detected that no signal is present on the line, and/or no line is present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDsuCsuInitState 1.3.6.1.4.1.18.3.4.30.1.1.22
Indictes the state of the DSU/CSU initialization sequence. The state will indicate if the DSU/CSU has been initialized and is in the *monitor* state polling the card for line condition, or in the *loopback state running a user-initiated loopback
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER startup(1), init(2), monitor(3), loopback(4)  

wfDsuCsuIfTrap 1
Indicates a change in the status of the line. The value returned in the trap will indicate the current state as defined in wfDsuCsuServiceStatus.
TRAP-TYPE