Wellfleet-LOADER-MIB

File: Wellfleet-LOADER-MIB.mib (56856 bytes)

Imported modules

RFC1155-SMI RFC-1212 Wellfleet-COMMON-MIB

Imported symbols

Counter OBJECT-TYPE wfSoftwareConfig

Defined Values

wfProtocols 1.3.6.1.4.1.18.3.2.1
OBJECT IDENTIFIER    

wfIPROTOLoad 1.3.6.1.4.1.18.3.2.1.1
Bit mask for loading the IP components on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDECNETLoad 1.3.6.1.4.1.18.3.2.1.2
Bit mask for loading the DECNet router on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfATLoad 1.3.6.1.4.1.18.3.2.1.3
Bit mask for loading the AppleTalk router on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfXNSLoad 1.3.6.1.4.1.18.3.2.1.4
Bit mask for loading the XNS router on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIPXLoad 1.3.6.1.4.1.18.3.2.1.5
Bit mask for loading the IPX router on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfOSILoad 1.3.6.1.4.1.18.3.2.1.6
Bit mask for loading the ISO router on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfX25DTELoad 1.3.6.1.4.1.18.3.2.1.7
Bit mask for loading the X.25 DTE protocol on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfX25DCELoad 1.3.6.1.4.1.18.3.2.1.8
Bit mask for loading the X.25 DCE protocol on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfVINESLoad 1.3.6.1.4.1.18.3.2.1.9
Bit mask for loading the VINES router on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFRLoad 1.3.6.1.4.1.18.3.2.1.10
Bit mask for loading the Frame Relay master on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRARPLoad 1.3.6.1.4.1.18.3.2.1.11
Bit mask for loading Reverse ARP master on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfATMLoad 1.3.6.1.4.1.18.3.2.1.12
Bit mask for loading the ATM master on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDLSLoad 1.3.6.1.4.1.18.3.2.1.13
Bit mask for loading the DLS master on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfLNMLoad 1.3.6.1.4.1.18.3.2.1.14
Bit mask for loading the LNM master on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfTelnetLoad 1.3.6.1.4.1.18.3.2.1.15
Bit mask for loading the Telnet protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfTFTPLoad 1.3.6.1.4.1.18.3.2.1.16
Bit mask for loading the TFTP protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSNMPLoad 1.3.6.1.4.1.18.3.2.1.17
Bit mask for loading the SNMP protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfTCPLoad 1.3.6.1.4.1.18.3.2.1.18
Bit mask for loading the TCP protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfBGPLoad 1.3.6.1.4.1.18.3.2.1.19
Bit mask for loading the BGP protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfEGPLoad 1.3.6.1.4.1.18.3.2.1.20
Bit mask for loading the EGP protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfOSPFLoad 1.3.6.1.4.1.18.3.2.1.21
Bit mask for loading the OSPF protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfWPROXYLoad 1.3.6.1.4.1.18.3.2.1.22
Bit mask for loading the WPROXY protocols on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfLLC2Load 1.3.6.1.4.1.18.3.2.1.23
Bit mask for loading the LLC2 master on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSMDSLoad 1.3.6.1.4.1.18.3.2.1.24
Bit mask for loading the SMDS protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfPPPLoad 1.3.6.1.4.1.18.3.2.1.25
Bit mask for loading PPP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfPktCaptureLoad 1.3.6.1.4.1.18.3.2.1.26
Bit mask for loading Pcap on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFRSWCNGCLoad 1.3.6.1.4.1.18.3.2.1.27
Bit mask for loading FrswCngc on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSWPROXYLoad 1.3.6.1.4.1.18.3.2.1.28
Bit mask for loading Switch Proxy on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFRSWLoad 1.3.6.1.4.1.18.3.2.1.29
Bit mask for loading FRSW on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSWSMDSLoad 1.3.6.1.4.1.18.3.2.1.30
Bit mask for loading SWSMDS on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNBASELoad 1.3.6.1.4.1.18.3.2.1.31
Bit mask for loading NBASE on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSDLCLoad 1.3.6.1.4.1.18.3.2.1.32
Bit mask for loading SDLC on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfTNCLoad 1.3.6.1.4.1.18.3.2.1.33
Bit mask for loading Outbound Telnet on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfLAPBLoad 1.3.6.1.4.1.18.3.2.1.34
Bit mask for loading the LAPB protocol on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDebugLoad 1.3.6.1.4.1.18.3.2.1.35
Bit mask for loading Debug on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNBIPLoad 1.3.6.1.4.1.18.3.2.1.36
Bit mask for loading NBIP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfATMCsLoad 1.3.6.1.4.1.18.3.2.1.37
Bit mask for loading ATM master on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDvmrpLoad 1.3.6.1.4.1.18.3.2.1.38
Bit mask for loading DVMRP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIgmpLoad 1.3.6.1.4.1.18.3.2.1.39
Bit mask for loading IGMP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfISDNLoad 1.3.6.1.4.1.18.3.2.1.40
Bit mask for loading ISDN on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfLMLoad 1.3.6.1.4.1.18.3.2.1.41
Bit mask for loading LM on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfPingLoad 1.3.6.1.4.1.18.3.2.1.42
Bit mask for loading PING on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAPPNCpLoad 1.3.6.1.4.1.18.3.2.1.43
Bit mask for loading the APPN CP soloist on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAPPNLsLoad 1.3.6.1.4.1.18.3.2.1.44
Bit mask for loading the APPN LS gates on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfWcpLoad 1.3.6.1.4.1.18.3.2.1.45
Bit mask for loading the WCP control gate on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFTPLoad 1.3.6.1.4.1.18.3.2.1.46
Bit mask for loading the FTP protocol on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfARPLoad 1.3.6.1.4.1.18.3.2.1.47
Bit mask for loading ARP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSYSLLoad 1.3.6.1.4.1.18.3.2.1.48
Bit mask for loading SYSLOG on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfBGPRSLoad 1.3.6.1.4.1.18.3.2.1.49
Bit mask for loading BGP Route Server on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfATMLeLoad 1.3.6.1.4.1.18.3.2.1.50
Bit mask for loading ATM LE on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfCRMLoad 1.3.6.1.4.1.18.3.2.1.51
Bit mask for loading Circuit Resource Manager on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIPEXLoad 1.3.6.1.4.1.18.3.2.1.52
Bit mask for loading IPEX on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSt2Load 1.3.6.1.4.1.18.3.2.1.53
Bit mask for loading ST2 on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNLSPLoad 1.3.6.1.4.1.18.3.2.1.54
Bit mask for loading NLSP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSTATSLoad 1.3.6.1.4.1.18.3.2.1.55
Bit mask for loading STATS on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNPTLoad 1.3.6.1.4.1.18.3.2.1.56
Bit mask for loading STATS on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRREDUNDLoad 1.3.6.1.4.1.18.3.2.1.57
Bit mask for loading RREDUND on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfATMSigLoad 1.3.6.1.4.1.18.3.2.1.58
Bit mask for loading ATM signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIPv6Load 1.3.6.1.4.1.18.3.2.1.59
Bit mask for loading IPv6 signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfBOTLoad 1.3.6.1.4.1.18.3.2.1.60
Bit mask for loading BOT signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfPimLoad 1.3.6.1.4.1.18.3.2.1.61
Bit mask for loading Protocol Independant Multicast (PIM) on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfLBCLoad 1.3.6.1.4.1.18.3.2.1.62
Bit mask for loading LBC on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfATMMcsLoad 1.3.6.1.4.1.18.3.2.1.63
Bit mask for loading ATM MCS on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfATMAsmLoad 1.3.6.1.4.1.18.3.2.1.64
Bit mask for loading ATM ASM on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfCPMLoad 1.3.6.1.4.1.18.3.2.1.65
Bit mask for loading ATM CPM on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfBAYSIGLoad 1.3.6.1.4.1.18.3.2.1.66
Bit mask for loading ATM Signalling (BAYSIG) on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfScmIpcLoad 1.3.6.1.4.1.18.3.2.1.67
Bit mask for loading SCM IPC on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNTPLoad 1.3.6.1.4.1.18.3.2.1.68
Bit mask for loading NTP signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRADIUSLoad 1.3.6.1.4.1.18.3.2.1.69
Bit mask for loading RADIUS on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRCMDSLoad 1.3.6.1.4.1.18.3.2.1.70
Bit mask for loading RCMDS signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDNSLoad 1.3.6.1.4.1.18.3.2.1.71
Bit mask for loading DNS signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfWepLoad 1.3.6.1.4.1.18.3.2.1.72
Bit mask for loading WEP encryption on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRipv6Load 1.3.6.1.4.1.18.3.2.1.73
Bit mask for loading Ripv6 signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMOSPFLoad 1.3.6.1.4.1.18.3.2.1.74
Bit mask for loading the MOSPF components on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRSVPLoad 1.3.6.1.4.1.18.3.2.1.75
Bit mask for loading the RSVP components on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIpSwitchLoad 1.3.6.1.4.1.18.3.2.1.76
Bit mask for loading IpSwitch/AutoLearn on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfPortMtxLoad 1.3.6.1.4.1.18.3.2.1.77
Bit mask for loading Port Matrix, only one slot for FX. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfConvStrLoad 1.3.6.1.4.1.18.3.2.1.78
Bit mask for loading Conversation Steer, only one slot for FX. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfS5ChasLoad 1.3.6.1.4.1.18.3.2.1.79
Bit mask for loading S5 signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFRSVCLoad 1.3.6.1.4.1.18.3.2.1.80
Bit mask for loading Frame Relay SVC software on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAOTLoad 1.3.6.1.4.1.18.3.2.1.81
Bit mask for loading AOT signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNATLoad 1.3.6.1.4.1.18.3.2.1.82
Bit mask for loading NAT signaling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFRPTLoad 1.3.6.1.4.1.18.3.2.1.83
Bit mask for loading Frame Relay PVC Passthru on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfHttpSrvLoad 1.3.6.1.4.1.18.3.2.1.84
Bit mask for loading the HTTP Server on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfStacLZSLoad 1.3.6.1.4.1.18.3.2.1.85
Bit mask for loading the Stac LZS control gate on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfASRLoad 1.3.6.1.4.1.18.3.2.1.86
Bit mask for loading ASR signalling on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNHRPLoad 1.3.6.1.4.1.18.3.2.1.87
Bit mask for loading NHRP on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAHBLoad 1.3.6.1.4.1.18.3.2.1.88
Bit mask for loading AHB on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfL2TPLoad 1.3.6.1.4.1.18.3.2.1.89
Bit mask for loading L2TP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfISDBLoad 1.3.6.1.4.1.18.3.2.1.90
Bit mask for loading ISDB on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfVCCTLoad 1.3.6.1.4.1.18.3.2.1.91
Bit mask for loading VCCT on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMpsLoad 1.3.6.1.4.1.18.3.2.1.92
Bit mask for loading MPOA Server on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfTAG1QLoad 1.3.6.1.4.1.18.3.2.1.93
Bit mask for loading TAG1Q (802.1q) on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMpcLoad 1.3.6.1.4.1.18.3.2.1.94
Bit mask for loading MPOA Client on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDVSLoad 1.3.6.1.4.1.18.3.2.1.95
Bit mask for loading DVS on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfVRRPLoad 1.3.6.1.4.1.18.3.2.1.96
Bit mask for loading VRRP on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDHCPLoad 1.3.6.1.4.1.18.3.2.1.97
Bit mask for loading DHCP on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfCAPILoad 1.3.6.1.4.1.18.3.2.1.98
Bit mask for loading CAPI on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIPSECLoad 1.3.6.1.4.1.18.3.2.1.99
Bit mask for loading IPSec on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMplsLdpLoad 1.3.6.1.4.1.18.3.2.1.100
Bit mask for loading MPLS LDP module on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMplsMlmLoad 1.3.6.1.4.1.18.3.2.1.101
Bit mask for loading MPLS MLM module on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfBacPktGenLoad 1.3.6.1.4.1.18.3.2.1.102
Bit mask for loading Bac PktGen on slot 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIISISLoad 1.3.6.1.4.1.18.3.2.1.103
Bit mask for loading IISIS on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfCopsCLoad 1.3.6.1.4.1.18.3.2.1.104
Bit mask for loading COPS Client on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDiffServLoad 1.3.6.1.4.1.18.3.2.1.105
Bit mask for loading DiffServ on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIKELoad 1.3.6.1.4.1.18.3.2.1.106
Bit mask for loading Internet Key Exchange(IKE) module on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDsqmsProxyLoad 1.3.6.1.4.1.18.3.2.1.107
Bit mask for loading DSQMS Proxy on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfLinkModules 1.3.6.1.4.1.18.3.2.2
OBJECT IDENTIFIER    

wfENETIILoad 1.3.6.1.4.1.18.3.2.2.1
Bit mask for loading the Ethernet II driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfQENETLoad 1.3.6.1.4.1.18.3.2.2.2
Bit mask for loading the Quad Ethernet driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFDDILoad 1.3.6.1.4.1.18.3.2.2.3
Bit mask for loading the FDDI driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDSDELoad 1.3.6.1.4.1.18.3.2.2.4
Bit mask for loading the Dual Sync - Dual Enet driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDSDEIILoad 1.3.6.1.4.1.18.3.2.2.5
Bit mask for loading the Dual Sync - Dual Enet II driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfQSYNCLoad 1.3.6.1.4.1.18.3.2.2.6
Bit mask for loading the Quad Sync driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDTLoad 1.3.6.1.4.1.18.3.2.2.7
Bit mask for loading the Dual Token driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDSTLoad 1.3.6.1.4.1.18.3.2.2.8
Bit mask for loading the DST driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfT1IILoad 1.3.6.1.4.1.18.3.2.2.9
Bit mask for loading the T1 II driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfE1IILoad 1.3.6.1.4.1.18.3.2.2.10
Bit mask for loading the E1 II driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfHSSILoad 1.3.6.1.4.1.18.3.2.2.11
Bit mask for loading the HSSI driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFNSDSELoad 1.3.6.1.4.1.18.3.2.2.12
Bit mask for loading the FNSDSE driver on slot 2 (FNES Only). The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFNSDSDTLoad 1.3.6.1.4.1.18.3.2.2.13
Bit mask for loading the FNSDSDT driver on slot 2 (FNTS Only). The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMCT1Load 1.3.6.1.4.1.18.3.2.2.14
Bit mask for loading the MCT1 driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfANLoad 1.3.6.1.4.1.18.3.2.2.15
Bit mask for loading the AN (AccessNode) driver. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFNSDSETLoad 1.3.6.1.4.1.18.3.2.2.16
Bit mask for loading the FNSDSET (ie. Fibermux IN Special) driver on slot 2 (IN Only). The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMCT1E1Load 1.3.6.1.4.1.18.3.2.2.17
Bit mask for loading the MCT1/E1 driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfEFDDILoad 1.3.6.1.4.1.18.3.2.2.18
Bit mask for loading the EFDDI (ie. QENET/FDDI LANNET IN) module driver on slot 2 (IN Only).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfHLSLoad 1.3.6.1.4.1.18.3.2.2.19
Bit mask for loading the Hughes LAN Systems Module driver on slot 2 (IN Only).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfChipcomLoad 1.3.6.1.4.1.18.3.2.2.20
Bit mask for loading the Chipcom Module driver on slot 2 (IN Only).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAtmcLoad 1.3.6.1.4.1.18.3.2.2.21
Bit mask for loading the ATMC driver on the ARE in slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfHDWANLMLoad 1.3.6.1.4.1.18.3.2.2.22
Bit mask for loading the hdwanlm module driver on slots 1-14
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDE100Load 1.3.6.1.4.1.18.3.2.2.23
Bit mask for loading the DE100 (dual ethernet 100 MB) driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAtmc5000Load 1.3.6.1.4.1.18.3.2.2.24
Bit mask for loading the ATMC 5000 AH driver on the ARE in slots 1-14. slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfArnLoad 1.3.6.1.4.1.18.3.2.2.25
Bit mask for loading the ARN Common Module driver. This is a single slot system so only the MSBit is supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFntsLoad 1.3.6.1.4.1.18.3.2.2.26
Bit mask for loading the Fnts Module driver on slot 2 (IN Only).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSQE100Load 1.3.6.1.4.1.18.3.2.2.27
Bit mask for loading the 100MB Ethernet Module driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfGigEnetLoad 1.3.6.1.4.1.18.3.2.2.28
Bit mask for loading the Gigabit Ethernet Module driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFBRLoad 1.3.6.1.4.1.18.3.2.2.29
Bit mask for loading the FBR Common Module driver. This is a single slot system so only the MSBit is supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDrivers 1.3.6.1.4.1.18.3.2.3
OBJECT IDENTIFIER    

wfLANCELoad 1.3.6.1.4.1.18.3.2.3.1
Bit mask for loading the LANCE chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfILACCLoad 1.3.6.1.4.1.18.3.2.3.2
Bit mask for loading the ILACC chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFSILoad 1.3.6.1.4.1.18.3.2.3.3
Bit mask for loading the FDDI System Interface (FSI) chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth. This attribute shall be used to configure the FSI chip driver on the appropriate slots for FDDI only (see wfHSSIFSILoad for other usage).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfTMS380Load 1.3.6.1.4.1.18.3.2.3.4
Bit mask for loading the TMS380 chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMK5025Load 1.3.6.1.4.1.18.3.2.3.5
Bit mask for loading the MK5025 chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDS2180Load 1.3.6.1.4.1.18.3.2.3.6
Bit mask for loading the DS2180 chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDS2181Load 1.3.6.1.4.1.18.3.2.3.7
Bit mask for loading the DS2181 chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDEFALoad 1.3.6.1.4.1.18.3.2.3.8
Bit mask for loading the AM99C10 chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2 and so forth. The AM99C10 chip is Content Addressable Memory (CAM) and the driver to control it is represented by this attribute. The generic name of this attribute shall be the Hardware Filter Driver which will also provide control of the Dual Ethernet Filter Accelerator (DEFA) chip.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAMZ8530Load 1.3.6.1.4.1.18.3.2.3.9
Bit mask for loading the AMZ8530 chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfHSSIFSILoad 1.3.6.1.4.1.18.3.2.3.10
Bit mask for loading the HSSI FSI chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMUNICHT1Load 1.3.6.1.4.1.18.3.2.3.11
Bit mask for loading the MUNICH chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth. The MUNICH chip is used on the MCT1 and MCE1 link modules
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfQsccSyncLoad 1.3.6.1.4.1.18.3.2.3.12
Bit mask for loading the Sync QUICC chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfQsccEnetLoad 1.3.6.1.4.1.18.3.2.3.13
Bit mask for loading the Ethernet QUICC chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfMunichLoad 1.3.6.1.4.1.18.3.2.3.14
Bit mask for loading the T1/E1 MUNICH chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth. The MUNICH chip is used on the MCT1 and MCE1 link modules
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfHilanceLoad 1.3.6.1.4.1.18.3.2.3.15
Bit mask for loading the Hilance driver for the ASN on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAtmAlcLoad 1.3.6.1.4.1.18.3.2.3.16
Bit mask for loading the ATM Link Module driver for the FRE-2 on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRptrLoad 1.3.6.1.4.1.18.3.2.3.17
Bit mask for loading the AN 802.3 driver on slot 1 - MSB represents slot 1 - Only valid slot
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfIsacLoad 1.3.6.1.4.1.18.3.2.3.18
Bit mask for loading the ISAC D Channel chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfAtmizerLoad 1.3.6.1.4.1.18.3.2.3.19
Bit mask for loading the ATMizer driver for the ARE on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfNSC100MLoad 1.3.6.1.4.1.18.3.2.3.20
Bit mask for loading the National Semiconductor DP83810 driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfDCMMWLoad 1.3.6.1.4.1.18.3.2.3.21
Bit mask for loading the DCMMW on slot 1. The MSBit represents slot 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfHwCompLoad 1.3.6.1.4.1.18.3.2.3.22
Bit mask for loading the Hardware Compression driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRAEsaLoad 1.3.6.1.4.1.18.3.2.3.23
Bit mask for loading RAESA on slots 1-14. The MSBit represents slot 1, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfFntsAtmLoad 1.3.6.1.4.1.18.3.2.3.24
Bit mask for loading the Fnts Atm driver for the FNTS on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfRMONStatLoad 1.3.6.1.4.1.18.3.2.3.25
Bit mask for loading RMONSTAT on slot 1. The MSBit represents slot 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSEEQ100MLoad 1.3.6.1.4.1.18.3.2.3.26
Bit mask for loading the SEEQ 100MB Ethernet driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfSeeqGigLoad 1.3.6.1.4.1.18.3.2.3.27
Bit mask for loading the SEEQ Gigabit Ethernet driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represents slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfPQ2EnetLoad 1.3.6.1.4.1.18.3.2.3.28
Bit mask for loading PQ2 Enet on slot 1. The MSBit represents slot 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfTdmManagerLoad 1.3.6.1.4.1.18.3.2.3.29
Bit mask for loading TDM Manager on slot 1. The MSBit represents slot 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfPQ2DsyncLoad 1.3.6.1.4.1.18.3.2.3.30
Bit mask for loading DSYNC PMC driver on slot 1. The MSBit represents slot 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfVoIPLoad 1.3.6.1.4.1.18.3.2.3.31
Bit mask for loading T1/E1 DUAL PMC driver on slot 1. The MSBit represents slot 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

wfQsccVoIPLoad 1.3.6.1.4.1.18.3.2.3.32
Bit mask for loading the VoIP QUICC chip driver on slots 1-14. The MSBit represents slot 1, the next most significant bit represent s slot 2, and so forth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter