Wellfleet-MCT1-MIB

File: Wellfleet-MCT1-MIB.mib (60203 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
Wellfleet-COMMON-MIB

Imported symbols

Counter Gauge OBJECT-TYPE
DisplayString wfMcT1Group

Defined Types

WfMcT1ModEntry  
SEQUENCE    
  wfMcT1ModDelete INTEGER
  wfMcT1ModDisable INTEGER
  wfMcT1ModSlot INTEGER
  wfMcT1ModPrimaryClock INTEGER
  wfMcT1ModSecondaryClock INTEGER
  wfMcT1ModCurrentClock INTEGER
  wfMcT1ModExtClockOperational INTEGER
  wfMcT1ModLoop0ClockOperational INTEGER
  wfMcT1ModLoop1ClockOperational INTEGER
  wfMcT1ModRestart INTEGER

WfMcT1Entry  
SEQUENCE    
  wfMcT1Delete INTEGER
  wfMcT1Disable INTEGER
  wfMcT1State INTEGER
  wfMcT1Slot INTEGER
  wfMcT1Connector INTEGER
  wfMcT1OperationMode INTEGER
  wfMcT1Mtu INTEGER
  wfMcT1MunichVersion INTEGER
  wfMcT1Dsx1LineType INTEGER
  wfMcT1Dsx1ZeroCoding INTEGER
  wfMcT1Dsx1LoopbackConfig INTEGER
  wfMcT1Dsx1LineStatus INTEGER
  wfMcT1Dsx1SetupAlarmThreshold INTEGER
  wfMcT1Dsx1ClearAlarmThreshold INTEGER
  wfMcT1Dsx1SignalLevel INTEGER
  wfMcT1LoopbackDisable INTEGER
  wfMcT1Dsx1FDLOperationMode INTEGER
  wfMcT1BertTxOutputLevel INTEGER
  wfMcT1BertTestMode INTEGER
  wfMcT1BertLineCode INTEGER
  wfMcT1BertTestPattern INTEGER
  wfMcT1BertSendAlarm INTEGER
  wfMcT1DS2282Version INTEGER
  wfMcT1Restart INTEGER
  wfMcT1Loopback INTEGER
  wfMcT1FDLTargetAddress INTEGER

WfMcT1ConfigEntry  
SEQUENCE    
  wfMcT1ConfigSlot INTEGER
  wfMcT1ConfigConnector INTEGER
  wfMcT1BertRestart INTEGER
  wfMcT1BertPayldLb INTEGER
  wfMcT1BertLineLb INTEGER
  wfMcT1BertErrorInsert INTEGER
  wfMcT1Dsx1SendLoopCode INTEGER
  wfMcT1Dsx1SendFDLCode INTEGER

WfMcT1LineEntry  
SEQUENCE    
  wfMcT1LineDelete INTEGER
  wfMcT1LineDisable INTEGER
  wfMcT1LineState INTEGER
  wfMcT1LineSlot INTEGER
  wfMcT1LineConnector INTEGER
  wfMcT1LineLine INTEGER
  wfMcT1LineCct INTEGER
  wfMcT1LineBofl INTEGER
  wfMcT1LineBoflTmo INTEGER
  wfMcT1LineFractionalLpbk INTEGER
  wfMcT1LineChannelAssignment DisplayString
  wfMcT1LineMadr OCTET STRING
  wfMcT1LineWanProtocol INTEGER
  wfMcT1LineService INTEGER
  wfMcT1LineRateAdaption INTEGER
  wfMcT1LineIFTF INTEGER
  wfMcT1LineCRCSize INTEGER
  wfMcT1LineRxOctets Counter
  wfMcT1LineRxFrames Counter
  wfMcT1LineTxOctets Counter
  wfMcT1LineTxFrames Counter
  wfMcT1LineRxErrors Counter
  wfMcT1LineTxErrors Counter
  wfMcT1LineLackRxResources Counter
  wfMcT1LineLackTxResources Counter
  wfMcT1LineTxUnderflows Counter
  wfMcT1LineRxOverflows Counter
  wfMcT1LineRxNullFrames Counter
  wfMcT1LineRxShortFrames Counter
  wfMcT1LineRxLossSyncs Counter
  wfMcT1LineRxCRCErrors Counter
  wfMcT1LineRxNonOctetBits Counter
  wfMcT1LineRxLongFrames Counter
  wfMcT1LineRxAbortFrames Counter
  wfMcT1LineRxDescOverflows Counter
  wfMcT1LineTurboBofl INTEGER
  wfMcT1LineBoflNum INTEGER
  wfMcT1LineBoflLen INTEGER
  wfMcT1LineRxIntProcs Counter
  wfMcT1LineTxIntProcs Counter
  wfMcT1LineRxPktCorruptions Counter
  wfMcT1LineRxReplenMisses Counter
  wfMcT1LineRxIFCs Counter
  wfMcT1LineCfgTxQueueLength INTEGER
  wfMcT1LineCfgRxQueueLength INTEGER
  wfMcT1LineTxQueueLength INTEGER
  wfMcT1LineRxQueueLength INTEGER
  wfMcT1LineTxQueueEmpty INTEGER
  wfMcT1LineMtu INTEGER
  wfMcT1LineRestart INTEGER
  wfMcT1LineLineNumber INTEGER

WfMcT1Dsx1CurrentEntry  
SEQUENCE    
  wfMcT1Dsx1CurrentSlot INTEGER
  wfMcT1Dsx1CurrentConnector INTEGER
  wfMcT1Dsx1CurrentIntervalTimer Gauge
  wfMcT1Dsx1CurrentESs Gauge
  wfMcT1Dsx1CurrentSESs Gauge
  wfMcT1Dsx1CurrentBESs Gauge
  wfMcT1Dsx1CurrentUASs Gauge
  wfMcT1Dsx1CurrentCSSs Gauge
  wfMcT1Dsx1CurrentBPVs Gauge

WfMcT1Dsx1IntervalEntry  
SEQUENCE    
  wfMcT1Dsx1IntervalSlot INTEGER
  wfMcT1Dsx1IntervalConnector INTEGER
  wfMcT1Dsx1IntervalNumber INTEGER
  wfMcT1Dsx1IntervalESs Gauge
  wfMcT1Dsx1IntervalSESs Gauge
  wfMcT1Dsx1IntervalBESs Gauge
  wfMcT1Dsx1IntervalUASs Gauge
  wfMcT1Dsx1IntervalCSSs Gauge
  wfMcT1Dsx1IntervalBPVs Gauge

WfMcT1Dsx1TotalEntry  
SEQUENCE    
  wfMcT1Dsx1TotalSlot INTEGER
  wfMcT1Dsx1TotalConnector INTEGER
  wfMcT1Dsx1TotalVITR Gauge
  wfMcT1Dsx1TotalESs Gauge
  wfMcT1Dsx1TotalSESs Gauge
  wfMcT1Dsx1TotalBESs Gauge
  wfMcT1Dsx1TotalUASs Gauge
  wfMcT1Dsx1TotalCSSs Gauge
  wfMcT1Dsx1TotalBPVs Gauge

WfMcT1AnsiEntry  
SEQUENCE    
  wfMcT1AnsiSlot INTEGER
  wfMcT1AnsiConnector INTEGER
  wfMcT1AnsiCRCCounts Counter
  wfMcT1AnsiBPVCounts Counter
  wfMcT1AnsiOOFCounts Counter
  wfMcT1AnsiFECounts Counter
  wfMcT1AnsiESCounts Counter
  wfMcT1AnsiSESCounts Counter
  wfMcT1AnsiUASCounts Counter
  wfMcT1AnsiPRMR0Counts Counter
  wfMcT1AnsiPRMR1Counts Counter
  wfMcT1AnsiPRMR2Counts Counter
  wfMcT1AnsiPRMR3Counts Counter
  wfMcT1AnsiPRMESCounts Counter
  wfMcT1AnsiPRMSESCounts Counter
  wfMcT1AnsiPRMECounts Counter

WfMcT1BertStatsEntry  
SEQUENCE    
  wfMcT1BertStatsSlot INTEGER
  wfMcT1BertStatsConnector INTEGER
  wfMcT1BertStatsBitErrors Counter
  wfMcT1BertStatsBits Counter

Defined Values

wfMcT1ModTable 1.3.6.1.4.1.18.3.4.8.1
MCT1 MOD record - Contains MCT1 module Configuration parameters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1ModEntry

wfMcT1ModEntry 1.3.6.1.4.1.18.3.4.8.1.1
An entry in the MCT1 Base table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1ModEntry  

wfMcT1ModDelete 1.3.6.1.4.1.18.3.4.8.1.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfMcT1ModDisable 1.3.6.1.4.1.18.3.4.8.1.1.2
Enable/Disable parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfMcT1ModSlot 1.3.6.1.4.1.18.3.4.8.1.1.3
Instance ID slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1ModPrimaryClock 1.3.6.1.4.1.18.3.4.8.1.1.4
Specifies the primary source for T1 transmit timing. Both T1 ports use the same T1 transmit timing source. The options for T1 timing source are internal timing source, loop timing from either T1 port and an external timing source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(1), loop0(2), loop1(3), int(4)  

wfMcT1ModSecondaryClock 1.3.6.1.4.1.18.3.4.8.1.1.5
Specifies the secondary source for T1 transmit timing. During normal operation T1 transmit timing is derived from the primary timing source. If the primary timing source fails, the software switches to secondary timing source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER external(1), loop0(2), loop1(3), int(4)  

wfMcT1ModCurrentClock 1.3.6.1.4.1.18.3.4.8.1.1.6
Indicates the clock source currently in use
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), int(3)  

wfMcT1ModExtClockOperational 1.3.6.1.4.1.18.3.4.8.1.1.7
Indicates whether the External clock is operational
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oper(1), unoper(2)  

wfMcT1ModLoop0ClockOperational 1.3.6.1.4.1.18.3.4.8.1.1.8
Indicates whether the timing source from port 1 is operational
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oper(1), unoper(2)  

wfMcT1ModLoop1ClockOperational 1.3.6.1.4.1.18.3.4.8.1.1.9
Indicates whether the timing source from port 2 is operational
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oper(1), unoper(2)  

wfMcT1ModRestart 1.3.6.1.4.1.18.3.4.8.1.1.10
Indicates Module gate should be restarted to read new configuration
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfMcT1Table 1.3.6.1.4.1.18.3.4.8.2
MCT1 line record - Contains MUNICH32 Configuration parameters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1Entry

wfMcT1Entry 1.3.6.1.4.1.18.3.4.8.2.1
An entry in the MCT1 table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1Entry  

wfMcT1Delete 1.3.6.1.4.1.18.3.4.8.2.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfMcT1Disable 1.3.6.1.4.1.18.3.4.8.2.1.2
Enable/Disable parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfMcT1State 1.3.6.1.4.1.18.3.4.8.2.1.3
Line Driver state variable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER init(1), up(2), bert(3), loopback(4), redalarm(5), yelalarm(6), bluealarm(7), notpresent(8)  

wfMcT1Slot 1.3.6.1.4.1.18.3.4.8.2.1.4
Instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1Connector 1.3.6.1.4.1.18.3.4.8.2.1.5
Instance ID Connector, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1OperationMode 1.3.6.1.4.1.18.3.4.8.2.1.6
An option to generate and analyze specific test patterns is provided in BERT mode of operation. Only one T1 port can be in BERT mode at a time. This attribute selects normal or BERT mode of operation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER default(1), bert(2)  

wfMcT1Mtu 1.3.6.1.4.1.18.3.4.8.2.1.7
MTU parameter. Specifies the largest frame size that can be received by the MCT1 link module. Any received frame which is larger than the MTU will be discarded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 3..4608  

wfMcT1MunichVersion 1.3.6.1.4.1.18.3.4.8.2.1.8
Specifies version number of the MUNICH chip used
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v1(1), v2(2)  

wfMcT1Dsx1LineType 1.3.6.1.4.1.18.3.4.8.2.1.9
Selects between the two framing formats supported - D4 and ESF. The sailent differences between the two formats are the number of frames per superframe and the use of F-bit position.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER esf(2), d4(3)  

wfMcT1Dsx1ZeroCoding 1.3.6.1.4.1.18.3.4.8.2.1.10
Selects between the two Zero Code Suppression formats used on the link. In B8ZS coding, any outgoing stream of eight consecutive zeroes is replaced with a B8ZS code word. Any received B8ZS code is replaced with all zeroes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER b8zs(2), ami(5)  

wfMcT1Dsx1LoopbackConfig 1.3.6.1.4.1.18.3.4.8.2.1.11
Indicates the loopback configuration of the T1 interface. The interface can be in the following loopback states: Payload loopback and Line loopback or no loopback. The loopbacks can be initiated by the manager of this device or by the far end. The loopbacks initiated by the far end are NETREQPAYLOADLOOP and NETREQLINELOOP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noloop(1), mgrpayloadloop(2), mgrlineloop(3), netreqpayloadloop(4), netreqlineloop(5), otherloop(6)  

wfMcT1Dsx1LineStatus 1.3.6.1.4.1.18.3.4.8.2.1.12
Indicates the line status of the T1 interface. It contains loopback state and alarm state information. The Dsx1LineStatus is a bit map therefore it can represent multiple loopback and alarm states simultaneously.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noalarm(1), farendalarm(2), alarmindicationsignal(4), lossofframe(8), lossofsignal(16), loopbackstate(32)  

wfMcT1Dsx1SetupAlarmThreshold 1.3.6.1.4.1.18.3.4.8.2.1.13
Specifies setup time for performance failure conditions, in seconds. When a performance defect is present for greater than the time specified by this parameter a performance failure is registered and a message is logged.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER threshold2(2), threshold4(4), threshold6(6), threshold8(8), threshold10(10)  

wfMcT1Dsx1ClearAlarmThreshold 1.3.6.1.4.1.18.3.4.8.2.1.14
Specifies clear time for performance failure conditions, in seconds. When a performance failure condition has been cleared for greater than the time specified by this parameter then the failure cleared condition is registered and a message is logged.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER threshold2(2), threshold4(4), threshold6(6), threshold8(8), threshold10(10)  

wfMcT1Dsx1SignalLevel 1.3.6.1.4.1.18.3.4.8.2.1.15
Specifies T1 transmit power level, in terms of DB. They translate into cable length as follows: 0.0dB -> 0-133 ft 0.5dB -> 133-266 ft 0.8dB -> 266-399 ft 1.1dB -> 399-533 ft 1.5dB -> 533-655 ft
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER minus15(1), minus7point5(2), minus0(3), pluspoint5(4), pluspoint8(5), plus1point1(6), plus1point5(7)  

wfMcT1LoopbackDisable 1.3.6.1.4.1.18.3.4.8.2.1.16
The MCT1 link module is capable of detecting loop up and loop down codes received from the far end. This parameter enables or disbales loop up/down code detection circuitry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfMcT1Dsx1FDLOperationMode 1.3.6.1.4.1.18.3.4.8.2.1.17
Select between the two FDL modes of operation. The AT&T mode, 54016 is based on AT&T publication 54015-1989. The ANSI mode, T1403 is based on ANSI publication T1.403-1989
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER oper54016(1), opert1403(2)  

wfMcT1BertTxOutputLevel 1.3.6.1.4.1.18.3.4.8.2.1.18
Specifies T1 transmit power level, in terms of DB while the T1 port is in BERT mode. The power levels translate into cable length as follows: 0.0dB -> 0-133 ft 0.5dB -> 133-266 ft 0.8dB -> 266-399 ft 1.1dB -> 399-533 ft 1.5dB -> 533-655 ft
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER minus15(1), minus7point5(2), minus0(3), pluspoint5(4), pluspoint8(5), plus1point1(6), plus1point5(7)  

wfMcT1BertTestMode 1.3.6.1.4.1.18.3.4.8.2.1.19
Selects between the framing formats while in bert mode of operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t1(1), sf(2), esf(3)  

wfMcT1BertLineCode 1.3.6.1.4.1.18.3.4.8.2.1.20
Selects between the two Zero Code Suppression formats used on the link while in BERT mode. In B8ZS coding, any outgoing stream of eight consecutive zeroes is replaced with a B8ZS code word. Any received B8ZS code is replaced with all zeroes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ami(1), b8zs(2)  

wfMcT1BertTestPattern 1.3.6.1.4.1.18.3.4.8.2.1.21
When a T1 port is in BERT mode, it is capable of generating a set of known patterns. This paramater selects between those patterns
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER zeros(1), ones(2), qrss(3), fifteen(4), fifteeninv(5), twenty(6), twentythree(7), twentythreeinv(8)  

wfMcT1BertSendAlarm 1.3.6.1.4.1.18.3.4.8.2.1.22
Specifies a blue or yellow alarm to be transmitted while in BERT mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER blue(1), yellow(2), disabled(3)  

wfMcT1DS2282Version 1.3.6.1.4.1.18.3.4.8.2.1.23
Specifies version number of DS2282 chip
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfMcT1Restart 1.3.6.1.4.1.18.3.4.8.2.1.24
Indicates Port gate should be restarted to read new configuration
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfMcT1Loopback 1.3.6.1.4.1.18.3.4.8.2.1.25
Selects line or payload loopback to be activated locally
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER linelb(1), payldlb(2), deactivate(3)  

wfMcT1FDLTargetAddress 1.3.6.1.4.1.18.3.4.8.2.1.26
Selects between the two FDL target address modes
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER az(1), by(2)  

wfMcT1ConfigTable 1.3.6.1.4.1.18.3.4.8.3
MCT1 configuration record - Contains MUNICH32 and Framer write only Configuration parameters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1ConfigEntry

wfMcT1ConfigEntry 1.3.6.1.4.1.18.3.4.8.3.1
An entry in the MCT1 Config table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1ConfigEntry  

wfMcT1ConfigSlot 1.3.6.1.4.1.18.3.4.8.3.1.1
Instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1ConfigConnector 1.3.6.1.4.1.18.3.4.8.3.1.2
Instance ID Connector, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1BertRestart 1.3.6.1.4.1.18.3.4.8.3.1.3
Reset counters on BERT device
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER restart(1), noaction(10)  

wfMcT1BertPayldLb 1.3.6.1.4.1.18.3.4.8.3.1.4
Selects a payload loopback code to be sent to the far end by the FDL while in BERT mode. It can be a payload loopback activate or deactivate code.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER act(1), deact(2), noaction(10)  

wfMcT1BertLineLb 1.3.6.1.4.1.18.3.4.8.3.1.5
Selects a line loopback code to be sent to the far end while in BERT mode. It can be a line loopback activate or deactivate code using the hardware on the MCT1 board or it can be a code sent by the FDL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lpup(1), lpdn(2), fdlact(3), fdldeact(4), noaction(10)  

wfMcT1BertErrorInsert 1.3.6.1.4.1.18.3.4.8.3.1.6
Indicates that an error be injected into the transmitted data stream while in BERT mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER config(1), thousandconfig(2), millionconfig(3), disable(4), noaction(10)  

wfMcT1Dsx1SendLoopCode 1.3.6.1.4.1.18.3.4.8.3.1.7
Selects a Loop Up/Down code to be sent to the remote end
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loopup(1), loopdn(2), noaction(10)  

wfMcT1Dsx1SendFDLCode 1.3.6.1.4.1.18.3.4.8.3.1.8
Selects an FDL code to be sent to the remote end
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ci(1), univlbdeact(2), ia(3), linelbdeact(4), pyldlbact(5), pyldlbdeact(6), ib(7), noaction(10)  

wfMcT1LineTable 1.3.6.1.4.1.18.3.4.8.4
MCT1 Channel record - Contains configuration parameters and statistics for MUNICH32 which are channel specific.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1LineEntry

wfMcT1LineEntry 1.3.6.1.4.1.18.3.4.8.4.1
An entry in the MCT1CHANNEL table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1LineEntry  

wfMcT1LineDelete 1.3.6.1.4.1.18.3.4.8.4.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfMcT1LineDisable 1.3.6.1.4.1.18.3.4.8.4.1.2
Enable/Disable parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfMcT1LineState 1.3.6.1.4.1.18.3.4.8.4.1.3
Line Driver state variable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3), loopback(4), wait(5), channel(6), stop(7), notpresent(8)  

wfMcT1LineSlot 1.3.6.1.4.1.18.3.4.8.4.1.4
Instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1LineConnector 1.3.6.1.4.1.18.3.4.8.4.1.5
Instance ID Connector, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1LineLine 1.3.6.1.4.1.18.3.4.8.4.1.6
Line number for this line instance, filled in by driver. The line number corresponds to the position of the circuit, from 1 to 24, on the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..24  

wfMcT1LineCct 1.3.6.1.4.1.18.3.4.8.4.1.7
Circuit number for this line instance
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1023  

wfMcT1LineBofl 1.3.6.1.4.1.18.3.4.8.4.1.8
Selects Breath of Life (BOFL) parameter. If selected, a BOFL packet is sent out on the wire as often as specifies by the wfMcT1LineBoflTmo parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfMcT1LineBoflTmo 1.3.6.1.4.1.18.3.4.8.4.1.9
Indicates the time-period between BOFL packets
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..60  

wfMcT1LineFractionalLpbk 1.3.6.1.4.1.18.3.4.8.4.1.10
Any circuit on this T1 port is capable of being put into loopback, i.e. data coming into that circuit from the wire is mirrorred back onto the wire. This parameter enables or disables this loopback feature on any circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfMcT1LineChannelAssignment 1.3.6.1.4.1.18.3.4.8.4.1.11
Lists the time-slots which constitute this channel. User types in a list of time-slots from 1 to 24 separated by commas
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfMcT1LineMadr 1.3.6.1.4.1.18.3.4.8.4.1.12
Line MAC address, fixed - line driver fills in from the 48 bit address stored in the serial number prom.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfMcT1LineWanProtocol 1.3.6.1.4.1.18.3.4.8.4.1.13
WAN protocol selection is provided via this parameter. The supported protocols can be selected per circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), ppp(2), smds(3), framerelay(4), switch(5), sw(6)  

wfMcT1LineService 1.3.6.1.4.1.18.3.4.8.4.1.14
Service type for this circuit. Supports raw HDLC mode. Does not support LLC1 at this time. LLC1 mode will prefix the HDLC address and control fields to the frame. May support LLC1 mode in the future
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER hdlc(1), llc1(2)  

wfMcT1LineRateAdaption 1.3.6.1.4.1.18.3.4.8.4.1.15
Determines the number of bits and their bit positions within the time-slot. 64k selection uses all 8 bits in the time-slot. The two 56k selections use 7 of the 8 bits in the time-slot. 56k_MSB does not use the most significant bit and 56k_LSB does not use the least significant bit in the time-slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER adaption64k(1), msb(2), lsb(3)  

wfMcT1LineIFTF 1.3.6.1.4.1.18.3.4.8.4.1.16
Determines the Interframe time fill character to be transmitted by the MUNICH. In case of IFTF_FLAGS, 0x7E is sent and in case of IFTF_IDLES 0xff is sent as the interframe timefill characters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER flags(1), idles(2)  

wfMcT1LineCRCSize 1.3.6.1.4.1.18.3.4.8.4.1.17
Determines the CRC Size. When CRC32 is selected a 32 bit CRC is appended to the frame being transmitted and a 32 bit CRC check is performed on the received frame. When CRC16 is selected, a 16 bit CRC is appended to the transmitted frame and a 16 bit CRC is performed. on the received frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER crc32(1), crc16(2)  

wfMcT1LineRxOctets 1.3.6.1.4.1.18.3.4.8.4.1.18
Number of octets received without error
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxFrames 1.3.6.1.4.1.18.3.4.8.4.1.19
Number of frames received without error
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineTxOctets 1.3.6.1.4.1.18.3.4.8.4.1.20
Number of octets transmitted without error
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineTxFrames 1.3.6.1.4.1.18.3.4.8.4.1.21
Number of frames transmitted without error
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxErrors 1.3.6.1.4.1.18.3.4.8.4.1.22
Number of receive errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineTxErrors 1.3.6.1.4.1.18.3.4.8.4.1.23
Number of transmission errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineLackRxResources 1.3.6.1.4.1.18.3.4.8.4.1.24
Number of Rx frames dropped due to lack of buffer resources
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineLackTxResources 1.3.6.1.4.1.18.3.4.8.4.1.25
Number of Tx frames dropped due to lack of buffer resources
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineTxUnderflows 1.3.6.1.4.1.18.3.4.8.4.1.26
Number of Tx frames dropped due to Transmit underflow
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxOverflows 1.3.6.1.4.1.18.3.4.8.4.1.27
Number of Rx frames dropped due to Receive overflow
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxNullFrames 1.3.6.1.4.1.18.3.4.8.4.1.28
Number of short frames received (with no data bytes)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxShortFrames 1.3.6.1.4.1.18.3.4.8.4.1.29
Number of short frames received (less than or equal to two data bytes)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxLossSyncs 1.3.6.1.4.1.18.3.4.8.4.1.30
Loss of synchronization on receiver
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxCRCErrors 1.3.6.1.4.1.18.3.4.8.4.1.31
CRC error received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxNonOctetBits 1.3.6.1.4.1.18.3.4.8.4.1.32
Non-Octet bits received in frame
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxLongFrames 1.3.6.1.4.1.18.3.4.8.4.1.33
Frame longer than MFL received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxAbortFrames 1.3.6.1.4.1.18.3.4.8.4.1.34
Aborted frame received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxDescOverflows 1.3.6.1.4.1.18.3.4.8.4.1.35
Receive overflow on chip buffer
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineTurboBofl 1.3.6.1.4.1.18.3.4.8.4.1.36
DEBUG parameter - Turbo bofl enabled or disabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfMcT1LineBoflNum 1.3.6.1.4.1.18.3.4.8.4.1.37
DEBUG parameter - Number of breath of life packets per breath of life
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

wfMcT1LineBoflLen 1.3.6.1.4.1.18.3.4.8.4.1.38
DEBUG parameter - breath of life packet length
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 22..4450  

wfMcT1LineRxIntProcs 1.3.6.1.4.1.18.3.4.8.4.1.39
Receive Interrupt processing count
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineTxIntProcs 1.3.6.1.4.1.18.3.4.8.4.1.40
Tx interrupt processing count
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxPktCorruptions 1.3.6.1.4.1.18.3.4.8.4.1.41
Corruption check on receive
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxReplenMisses 1.3.6.1.4.1.18.3.4.8.4.1.42
Count of number of packet buffer misses while attempting to replenish driver receive ring
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineRxIFCs 1.3.6.1.4.1.18.3.4.8.4.1.43
Number of times the device changes its interframe time-fill
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1LineCfgTxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.44
Configured transmit queue length
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..336  

wfMcT1LineCfgRxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.45
Configured receive queue length
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..336  

wfMcT1LineTxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.46
Current transmit queue length
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfMcT1LineRxQueueLength 1.3.6.1.4.1.18.3.4.8.4.1.47
Current Receive queue length
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfMcT1LineTxQueueEmpty 1.3.6.1.4.1.18.3.4.8.4.1.48
The number of times the transmit ring is found empty when transmitting packets
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfMcT1LineMtu 1.3.6.1.4.1.18.3.4.8.4.1.49
MTU read-only parameter. Specifies the largest frame size that can be received by the MCT1 link module. Any received frame which is larger than the MTU will be discarded. Can be set in MCT1Entry TABLE by the user
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfMcT1LineRestart 1.3.6.1.4.1.18.3.4.8.4.1.50
Indicates channel gate should be restarted to read new configuration
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfMcT1LineLineNumber 1.3.6.1.4.1.18.3.4.8.4.1.51
line number for this line instance
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfMcT1Dsx1CurrentTable 1.3.6.1.4.1.18.3.4.8.5
The MCT1_DSX1 Current table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1Dsx1CurrentEntry

wfMcT1Dsx1CurrentEntry 1.3.6.1.4.1.18.3.4.8.5.1
per circuit MCT1_DSX1 current objects - wfMcT1Dsx1CurrentIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1Dsx1CurrentEntry  

wfMcT1Dsx1CurrentSlot 1.3.6.1.4.1.18.3.4.8.5.1.1
this corresponds to the Wellfleet Slot number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1Dsx1CurrentConnector 1.3.6.1.4.1.18.3.4.8.5.1.2
this corresponds to the Wellfleet Connector number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1Dsx1CurrentIntervalTimer 1.3.6.1.4.1.18.3.4.8.5.1.3
the number of seconds in the current 15 minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1CurrentESs 1.3.6.1.4.1.18.3.4.8.5.1.4
the number of errored seconds encountered by a DS1 interface in the current 15 minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1CurrentSESs 1.3.6.1.4.1.18.3.4.8.5.1.5
the number of severely errored seconds in the current 15 minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1CurrentBESs 1.3.6.1.4.1.18.3.4.8.5.1.6
the number of bursty errored seconds in the current 15 minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1CurrentUASs 1.3.6.1.4.1.18.3.4.8.5.1.7
the number of unavailable seconds in the current 15 minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1CurrentCSSs 1.3.6.1.4.1.18.3.4.8.5.1.8
the number of Controlled Slip seconds in the current 15 minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1CurrentBPVs 1.3.6.1.4.1.18.3.4.8.5.1.9
the number of bipolar violations in the current 15 minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1IntervalTable 1.3.6.1.4.1.18.3.4.8.6
The MCT1_DSX1 Interval table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1Dsx1IntervalEntry

wfMcT1Dsx1IntervalEntry 1.3.6.1.4.1.18.3.4.8.6.1
per circuit MCT1_DSX1 interval objects - wfMcT1Dsx1IntervalIndex corresponds to Wellfleet circuit number, wfMcT1Dsx1IntervalNumber is the numbered previous 15-minute interval
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1Dsx1IntervalEntry  

wfMcT1Dsx1IntervalSlot 1.3.6.1.4.1.18.3.4.8.6.1.1
this corresponds to the Wellfleet Slot number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1Dsx1IntervalConnector 1.3.6.1.4.1.18.3.4.8.6.1.2
this corresponds to the Wellfleet Connector number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1Dsx1IntervalNumber 1.3.6.1.4.1.18.3.4.8.6.1.3
1..96 where 1 is the most recent 15-minute interval and 96 is the least
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

wfMcT1Dsx1IntervalESs 1.3.6.1.4.1.18.3.4.8.6.1.4
the number of errored seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1IntervalSESs 1.3.6.1.4.1.18.3.4.8.6.1.5
the number of severely errored seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1IntervalBESs 1.3.6.1.4.1.18.3.4.8.6.1.6
the number of bursty errored seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1IntervalUASs 1.3.6.1.4.1.18.3.4.8.6.1.7
the number of unavailable seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1IntervalCSSs 1.3.6.1.4.1.18.3.4.8.6.1.8
the number of controlled slip seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1IntervalBPVs 1.3.6.1.4.1.18.3.4.8.6.1.9
the number of bipolar violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1TotalTable 1.3.6.1.4.1.18.3.4.8.7
The MCT1_DSX1 Total table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1Dsx1TotalEntry

wfMcT1Dsx1TotalEntry 1.3.6.1.4.1.18.3.4.8.7.1
per circuit MCT1_DSX1 total objects - wfMcT1Dsx1TotalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1Dsx1TotalEntry  

wfMcT1Dsx1TotalSlot 1.3.6.1.4.1.18.3.4.8.7.1.1
this corresponds to the Wellfleet Slot number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1Dsx1TotalConnector 1.3.6.1.4.1.18.3.4.8.7.1.2
this corresponds to the Wellfleet Connector number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1Dsx1TotalVITR 1.3.6.1.4.1.18.3.4.8.7.1.3
Indicates the number of valid 15 minute intervals in the previous 24 hour period
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1TotalESs 1.3.6.1.4.1.18.3.4.8.7.1.4
The number of errored seconds encountered by the DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1TotalSESs 1.3.6.1.4.1.18.3.4.8.7.1.5
The number of severely errored seconds encountered by a DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1TotalBESs 1.3.6.1.4.1.18.3.4.8.7.1.6
The number of bursty errored seconds encountered by a DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1TotalUASs 1.3.6.1.4.1.18.3.4.8.7.1.7
The number of unavailable seconds encountered by by a DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1TotalCSSs 1.3.6.1.4.1.18.3.4.8.7.1.8
The number of controlled slip seconds encountered by a DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1Dsx1TotalBPVs 1.3.6.1.4.1.18.3.4.8.7.1.9
The number of bipolar violations encountered by a DS1 interface in the previous 24 hour interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfMcT1AnsiTable 1.3.6.1.4.1.18.3.4.8.8
ANSI Statistics line record - This table contains the performance parameters for the ANSI register set
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1AnsiEntry

wfMcT1AnsiEntry 1.3.6.1.4.1.18.3.4.8.8.1
An entry in the MCT1 Ansi table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1AnsiEntry  

wfMcT1AnsiSlot 1.3.6.1.4.1.18.3.4.8.8.1.1
Instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1AnsiConnector 1.3.6.1.4.1.18.3.4.8.8.1.2
Instance ID Connector, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1AnsiCRCCounts 1.3.6.1.4.1.18.3.4.8.8.1.3
Counts CRC-6 error events
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiBPVCounts 1.3.6.1.4.1.18.3.4.8.8.1.4
Counts bipolar violations
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiOOFCounts 1.3.6.1.4.1.18.3.4.8.8.1.5
Counts out-of-frame error events
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiFECounts 1.3.6.1.4.1.18.3.4.8.8.1.6
Counts errors in the FPS framing pattern
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiESCounts 1.3.6.1.4.1.18.3.4.8.8.1.7
Counts errorred seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiSESCounts 1.3.6.1.4.1.18.3.4.8.8.1.8
Counts severly errorred seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiUASCounts 1.3.6.1.4.1.18.3.4.8.8.1.9
counts unavailable seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiPRMR0Counts 1.3.6.1.4.1.18.3.4.8.8.1.10
Counts PRMs that ewre received in the FDL in the last four seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiPRMR1Counts 1.3.6.1.4.1.18.3.4.8.8.1.11
Counts PRMs that ewre received in the FDL in the last four seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiPRMR2Counts 1.3.6.1.4.1.18.3.4.8.8.1.12
Counts PRMs that ewre received in the FDL in the last four seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiPRMR3Counts 1.3.6.1.4.1.18.3.4.8.8.1.13
Counts PRMs that ewre received in the FDL in the last four seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiPRMESCounts 1.3.6.1.4.1.18.3.4.8.8.1.14
Counts errorred seconds as reported in the Performance report messages
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiPRMSESCounts 1.3.6.1.4.1.18.3.4.8.8.1.15
Counts severely errorred seconds as reported in the Performance report messages
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1AnsiPRMECounts 1.3.6.1.4.1.18.3.4.8.8.1.16
Counts Performance report messages that are received in error
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1BertStatsTable 1.3.6.1.4.1.18.3.4.8.9
BERT Counter line record - This table contains the statistics for the BERT tester.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfMcT1BertStatsEntry

wfMcT1BertStatsEntry 1.3.6.1.4.1.18.3.4.8.9.1
An entry in the MCT1 Bert Stats table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfMcT1BertStatsEntry  

wfMcT1BertStatsSlot 1.3.6.1.4.1.18.3.4.8.9.1.1
Instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfMcT1BertStatsConnector 1.3.6.1.4.1.18.3.4.8.9.1.2
Instance ID Connector, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfMcT1BertStatsBitErrors 1.3.6.1.4.1.18.3.4.8.9.1.3
Bit error counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfMcT1BertStatsBits 1.3.6.1.4.1.18.3.4.8.9.1.4
Bit counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter