Wellfleet-OCX-MIB

File: Wellfleet-OCX-MIB.mib (7351 bytes)

Imported modules

RFC1155-SMI RFC-1212 Wellfleet-COMMON-MIB

Imported symbols

TimeTicks OBJECT-TYPE wfSonetGroup

Defined Types

WfOcxConfigEntry  
SEQUENCE    
  wfOcxConfigDelete INTEGER
  wfOcxConfigDisable INTEGER
  wfOcxConfigIndex INTEGER
  wfOcxConfigIfIndex INTEGER
  wfOcxConfigState INTEGER
  wfOcxConfigLineStatus INTEGER
  wfOcxConfigLastChange TimeTicks
  wfOcxConfigConnType INTEGER
  wfOcxConfigType INTEGER
  wfOcxConfigLineCoding INTEGER
  wfOcxConfigLineType INTEGER
  wfOcxConfigLoopbackConfig INTEGER
  wfOcxConfigManagerMethod INTEGER
  wfOcxConfigApsEnable INTEGER
  wfOcxConfigScrambling INTEGER
  wfOcxConfigClkSource INTEGER

Defined Values

wfOcxConfigTable 1.3.6.1.4.1.18.3.4.24.21
Ocx Configuration Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOcxConfigEntry

wfOcxConfigEntry 1.3.6.1.4.1.18.3.4.24.21.1
An entry in the Ocx Configuration table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOcxConfigEntry  

wfOcxConfigDelete 1.3.6.1.4.1.18.3.4.24.21.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOcxConfigDisable 1.3.6.1.4.1.18.3.4.24.21.1.2
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOcxConfigIndex 1.3.6.1.4.1.18.3.4.24.21.1.3
Index for this physical Sonet interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOcxConfigIfIndex 1.3.6.1.4.1.18.3.4.24.21.1.4
this is value of ifIndex from the Interfaces table of MIB II (RFC 1213).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOcxConfigState 1.3.6.1.4.1.18.3.4.24.21.1.5
State of the OCX Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), los(3), lof(4), ais(5), rdi(6), loopback(7), notpresent(20)  

wfOcxConfigLineStatus 1.3.6.1.4.1.18.3.4.24.21.1.6
the status of the OCX
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noalarm(1), los(2), lof(4), ais(8), rdi(16), loopback(128), otherfailure(512)  

wfOcxConfigLastChange 1.3.6.1.4.1.18.3.4.24.21.1.7
The value of sysUpTime at the time the interface entered its current operational state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

wfOcxConfigConnType 1.3.6.1.4.1.18.3.4.24.21.1.8
This variable describes the Connector Type for this interface. This Mib is used for various types, OC3, OC12, etc...
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER oc3(1), oc12(2), oc48(3)  

wfOcxConfigType 1.3.6.1.4.1.18.3.4.24.21.1.9
This variable identifies whether a SONET or a SDH signal is used across this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sonet(1), sdh(2)  

wfOcxConfigLineCoding 1.3.6.1.4.1.18.3.4.24.21.1.10
This variable describes the line coding for this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), b3zs(2), cmi(3), nrz(4), rz(5)  

wfOcxConfigLineType 1.3.6.1.4.1.18.3.4.24.21.1.11
This variable describes the line type for this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), shortsinglemode(2), longsinglemode(3), multimode(4), coax(5), utp(6)  

wfOcxConfigLoopbackConfig 1.3.6.1.4.1.18.3.4.24.21.1.12
the loopback configuration of the OCX interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noloop(1), selfloop(2), lineloop(3)  

wfOcxConfigManagerMethod 1.3.6.1.4.1.18.3.4.24.21.1.13
This attribute has no affect on the Hardware configuration. This attribute is purely for any Network Management Tool to determine whether it configured the OCX as Fractional or Clear.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER frac(1), clear(2)  

wfOcxConfigApsEnable 1.3.6.1.4.1.18.3.4.24.21.1.14
This attribute Enables or Disables the APS failover.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOcxConfigScrambling 1.3.6.1.4.1.18.3.4.24.21.1.15
This attribute turns scrambling on or off.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

wfOcxConfigClkSource 1.3.6.1.4.1.18.3.4.24.21.1.16
The source of the physical interface clocking signal, either internal or external.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER intrn(1), extrn(2)