Wellfleet-OCX-MIB
File:
Wellfleet-OCX-MIB.mib (7351 bytes)
Imported modules
Imported symbols
Defined Types
WfOcxConfigEntry |
|
SEQUENCE |
|
|
|
|
wfOcxConfigDelete |
INTEGER |
|
|
wfOcxConfigDisable |
INTEGER |
|
|
wfOcxConfigIndex |
INTEGER |
|
|
wfOcxConfigIfIndex |
INTEGER |
|
|
wfOcxConfigState |
INTEGER |
|
|
wfOcxConfigLineStatus |
INTEGER |
|
|
wfOcxConfigLastChange |
TimeTicks |
|
|
wfOcxConfigConnType |
INTEGER |
|
|
wfOcxConfigType |
INTEGER |
|
|
wfOcxConfigLineCoding |
INTEGER |
|
|
wfOcxConfigLineType |
INTEGER |
|
|
wfOcxConfigLoopbackConfig |
INTEGER |
|
|
wfOcxConfigManagerMethod |
INTEGER |
|
|
wfOcxConfigApsEnable |
INTEGER |
|
|
wfOcxConfigScrambling |
INTEGER |
|
|
wfOcxConfigClkSource |
INTEGER |
|
Defined Values
wfOcxConfigEntry |
1.3.6.1.4.1.18.3.4.24.21.1 |
An entry in the Ocx Configuration table |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
WfOcxConfigEntry |
|
|
wfOcxConfigDelete |
1.3.6.1.4.1.18.3.4.24.21.1.1 |
Create/Delete parameter |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
created(1), deleted(2) |
|
wfOcxConfigDisable |
1.3.6.1.4.1.18.3.4.24.21.1.2 |
Create/Delete parameter |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
wfOcxConfigIndex |
1.3.6.1.4.1.18.3.4.24.21.1.3 |
Index for this physical Sonet interface. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
wfOcxConfigIfIndex |
1.3.6.1.4.1.18.3.4.24.21.1.4 |
this is value of ifIndex from the Interfaces table of
MIB II (RFC 1213). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
wfOcxConfigState |
1.3.6.1.4.1.18.3.4.24.21.1.5 |
State of the OCX Port. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2), los(3), lof(4), ais(5), rdi(6), loopback(7), notpresent(20) |
|
wfOcxConfigLineStatus |
1.3.6.1.4.1.18.3.4.24.21.1.6 |
the status of the OCX |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noalarm(1), los(2), lof(4), ais(8), rdi(16), loopback(128), otherfailure(512) |
|
wfOcxConfigLastChange |
1.3.6.1.4.1.18.3.4.24.21.1.7 |
The value of sysUpTime at the time the interface entered
its current operational state. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
wfOcxConfigConnType |
1.3.6.1.4.1.18.3.4.24.21.1.8 |
This variable describes the Connector Type for this interface.
This Mib is used for various types, OC3, OC12, etc... |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
oc3(1), oc12(2), oc48(3) |
|
wfOcxConfigType |
1.3.6.1.4.1.18.3.4.24.21.1.9 |
This variable identifies whether a SONET or a SDH signal is used
across this interface. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
sonet(1), sdh(2) |
|
wfOcxConfigLineCoding |
1.3.6.1.4.1.18.3.4.24.21.1.10 |
This variable describes the line coding for this interface. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), b3zs(2), cmi(3), nrz(4), rz(5) |
|
wfOcxConfigLineType |
1.3.6.1.4.1.18.3.4.24.21.1.11 |
This variable describes the line type for this interface. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), shortsinglemode(2), longsinglemode(3), multimode(4), coax(5), utp(6) |
|
wfOcxConfigLoopbackConfig |
1.3.6.1.4.1.18.3.4.24.21.1.12 |
the loopback configuration of the OCX interface |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noloop(1), selfloop(2), lineloop(3) |
|
wfOcxConfigManagerMethod |
1.3.6.1.4.1.18.3.4.24.21.1.13 |
This attribute has no affect on the Hardware configuration.
This attribute is purely for any Network Management Tool
to determine whether it configured the OCX as Fractional
or Clear. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
frac(1), clear(2) |
|
wfOcxConfigApsEnable |
1.3.6.1.4.1.18.3.4.24.21.1.14 |
This attribute Enables or Disables the APS failover. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
wfOcxConfigScrambling |
1.3.6.1.4.1.18.3.4.24.21.1.15 |
This attribute turns scrambling on or off. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
on(1), off(2) |
|
wfOcxConfigClkSource |
1.3.6.1.4.1.18.3.4.24.21.1.16 |
The source of the physical interface clocking signal, either
internal or external. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
intrn(1), extrn(2) |
|