ZYXEL-AESCOMMON-MIB

File: ZYXEL-AESCOMMON-MIB.mib (15768 bytes)

Imported modules

RFC-1212 RFC1213-MIB SNMPv2-SMI
ZYXEL-MIB

Imported symbols

OBJECT-TYPE DisplayString ifIndex
Unsigned32 aesSeriesCommon

Defined Types

AesLineConfEntry  
SEQUENCE    
  aesLineConfAdslMode INTEGER
  aesLineConfEncap INTEGER
  aesLineConfVpi INTEGER
  aesLineConfVci INTEGER
  aesLineConfAnnexL INTEGER
  aesLineConfPmMode INTEGER
  aesLineConfRateMode INTEGER
  aesLineConfAnnexM INTEGER

AesBitLoadingEntry  
SEQUENCE    
  aesBitLoadingBits OCTET STRING
  aesBitLoadingAtucNumOfCarriers INTEGER
  aesBitLoadingAturNumOfCarriers INTEGER

AesLineStatusEntry  
SEQUENCE    
  aesLineStatusAdslMode INTEGER

Defined Values

aesMaxNumOfProfiles 1.3.6.1.4.1.890.1.5.11.1.1
The maximum number of ADSL profiles which the system supports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesLineConfTable 1.3.6.1.4.1.890.1.5.11.1.2
This table includes common attributes describing the ADSL line.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AesLineConfEntry

aesLineConfEntry 1.3.6.1.4.1.890.1.5.11.1.2.1
An entry in aesLineConfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AesLineConfEntry  

aesLineConfAdslMode 1.3.6.1.4.1.890.1.5.11.1.2.1.1
The mode of the ADSL line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER gDotLite(1), gDotDmt(2), t1Dot413(3), auto(4), etsi(5), adsl2(6), adsl2Plus(7)  

aesLineConfEncap 1.3.6.1.4.1.890.1.5.11.1.2.1.2
The encapsulation of the ADSL line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER llc(1), vc(2)  

aesLineConfVpi 1.3.6.1.4.1.890.1.5.11.1.2.1.3
The VPI of the ADSL line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

aesLineConfVci 1.3.6.1.4.1.890.1.5.11.1.2.1.4
The VCI of the ADSL line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

aesLineConfAnnexL 1.3.6.1.4.1.890.1.5.11.1.2.1.5
The annex L setting of the ADSL line(Only in AnnexA).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableNarrowMode(1), enableWideMode(2), disable(3)  

aesLineConfPmMode 1.3.6.1.4.1.890.1.5.11.1.2.1.6
The power management mode of the ADSL line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableL2Mode(1), enableL3Mode(2), disable(3)  

aesLineConfRateMode 1.3.6.1.4.1.890.1.5.11.1.2.1.7
Defines what form of transmit rate adaptation is configured on this modem. See ADSL Forum TR-005 [3] for more information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixed(1), adaptAtStartup(2), adaptAtRuntime(3)  

aesLineConfAnnexM 1.3.6.1.4.1.890.1.5.11.1.2.1.8
The annex M setting of the ADSL line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

aesLineDiagnostic 1.3.6.1.4.1.890.1.5.11.1.3
OBJECT IDENTIFIER    

aesAtucLineDiagLATN 1.3.6.1.4.1.890.1.5.11.1.3.1
Line Attenuation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAtucLineDiagSATN 1.3.6.1.4.1.890.1.5.11.1.3.2
Signal Attenuation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAtucLineDiagSNRM 1.3.6.1.4.1.890.1.5.11.1.3.3
Signal-to-Noise Ratio Margin.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAtucLineDiagACTATP 1.3.6.1.4.1.890.1.5.11.1.3.4
Actual Aggregate Transmit Power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAtucLineDiagATTNDR 1.3.6.1.4.1.890.1.5.11.1.3.5
Attainable Net Data Rate, in bps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32  

aesAturLineDiagLATN 1.3.6.1.4.1.890.1.5.11.1.3.6
Line Attenuation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAturLineDiagSATN 1.3.6.1.4.1.890.1.5.11.1.3.7
Signal Attenuation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAturLineDiagSNRM 1.3.6.1.4.1.890.1.5.11.1.3.8
Signal-to-Noise Ratio Margin.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAturLineDiagACTATP 1.3.6.1.4.1.890.1.5.11.1.3.9
Actual Aggregate Transmit Power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAturLineDiagATTNDR 1.3.6.1.4.1.890.1.5.11.1.3.10
Attainable Net Data Rate, in bps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32  

aesLineDiagTarget 1.3.6.1.4.1.890.1.5.11.1.3.11
Ifindex of the ADSL port which will be diagnosed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

aesLineDiagOps 1.3.6.1.4.1.890.1.5.11.1.3.12
The manager sets the object to one to start line diagnostics and the agent clears the object to zero when diagnostics is successfully completed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

aesLineDiagFailReason 1.3.6.1.4.1.890.1.5.11.1.3.13
The reason of failed diagnostics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

aesLineDiagPs 1.3.6.1.4.1.890.1.5.11.1.4
OBJECT IDENTIFIER    

aesAtucNumOfSubcarriersPerPort 1.3.6.1.4.1.890.1.5.11.1.4.1
The number of subcarriers per port for ATU-C.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesAturNumOfSubcarriersPerPort 1.3.6.1.4.1.890.1.5.11.1.4.2
The number of subcarriers per port for ATU-R.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesLineDiagPsCCFLirl1 1.3.6.1.4.1.890.1.5.11.1.4.3
Channel Characteristics Function H(f) per subcarrier. The value is the real part of a complex value in liner scale. The first two octets specify the li.rl value for subcarrier 1, and the second two octets specify the li.rl value for subcarrier 2, and so on. The object provides li.rl values for subcarrier 1 to 256.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesLineDiagPsCCFLirl2 1.3.6.1.4.1.890.1.5.11.1.4.4
Channel Characteristics Function H(f) per subcarrier. The value is the real part of a complex value in liner scale. The first two octets specify the li.rl value for subcarrier 257, and the second two octets specify the li.rl value for subcarrier 258, and so on. The object provides li.rl values for subcarrier 257 to 512.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesLineDiagPsCCFLiim1 1.3.6.1.4.1.890.1.5.11.1.4.5
Channel Characteristics Function H(f) per subcarrier. The value is the image part of a complex value in liner scale. The first two octets specify the li.im value for subcarrier 1, and the second two octets specify the li.im value for subcarrier 2, and so on. The object provides li.im values for subcarrier 1 to 256.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesLineDiagPsCCFLiim2 1.3.6.1.4.1.890.1.5.11.1.4.6
Channel Characteristics Function H(f) per subcarrier. The value is the image part of a complex value in liner scale. The first two octets specify the li.im value for subcarrier 257, and the second two octets specify the li.im value for subcarrier 258, and so on. The object provides li.im values for subcarrier 257 to 512.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesLineDiagPsCCFLog1 1.3.6.1.4.1.890.1.5.11.1.4.7
Channel Characteristics Function H(f) per subcarrier. The value provides magnitude value in a logarithmic scale. The first two octets specify the log value for subcarrier 1, and the second two octets specify the log value for subcarrier 2, and so on. The object provides log values for subcarrier 1 to 256.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesLineDiagPsCCFLog2 1.3.6.1.4.1.890.1.5.11.1.4.8
Channel Characteristics Function H(f) per subcarrier. The value provides magnitude value in a logarithmic scale. The first two octets specify the log value for subcarrier 257, and the second two octets specify the log value for subcarrier 258, and so on. The object provides log values for subcarrier 257 to 512.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesLineDiagPsQLN 1.3.6.1.4.1.890.1.5.11.1.4.9
Quiet Line Noise PSD QLN(f) per subcarrier. The first octet specify QLN for subcarrier 1, and the second octet specify QLN for subcarrier 2, and so on. The object provides QLN for subcarrier 1 to 512.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesLineDiagPsSNR 1.3.6.1.4.1.890.1.5.11.1.4.10
Signal-to-Noise Ratio SNR(f) per subcarrier. The first octet specify SNR for subcarrier 1, and the second octet specify SNR for subcarrier 2, and so on. The object provides SNR for subcarrier 1 to 512.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesMaxNumOfAlarmProfiles 1.3.6.1.4.1.890.1.5.11.1.5
The maximum number of ADSL alarm profiles which the system supports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesBitLoadingTable 1.3.6.1.4.1.890.1.5.11.1.6
This table provides the number of bits per carrier for each ADSL port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AesBitLoadingEntry

aesBitLoadingEntry 1.3.6.1.4.1.890.1.5.11.1.6.1
An entry in aesBitLoadingTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AesBitLoadingEntry  

aesBitLoadingBits 1.3.6.1.4.1.890.1.5.11.1.6.1.1
This object provides the number of bits for all carriers in the port. The first octet specify the number of bits for carrier 1, and the second octet specify the number of bits for carrier 2, and so on. The object provides the number of bits for carrier 1 to 512.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

aesBitLoadingAtucNumOfCarriers 1.3.6.1.4.1.890.1.5.11.1.6.1.2
The number of carriers for ATU-C.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesBitLoadingAturNumOfCarriers 1.3.6.1.4.1.890.1.5.11.1.6.1.3
The number of carriers for ATU-R.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

aesLineStatusTable 1.3.6.1.4.1.890.1.5.11.1.7
This table includes the ADSL line status.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AesLineStatusEntry

aesLineStatusEntry 1.3.6.1.4.1.890.1.5.11.1.7.1
An entry in aesLineStatusTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AesLineStatusEntry  

aesLineStatusAdslMode 1.3.6.1.4.1.890.1.5.11.1.7.1.1
The link up mode of the ADSL line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER gDotLite(1), gDotDmt(2), t1Dot413(3), etsi(4), adsl2(5), adsl2Plus(6)  

selt 1.3.6.1.4.1.890.1.5.11.1.8
OBJECT IDENTIFIER    

seltTarget 1.3.6.1.4.1.890.1.5.11.1.8.1
IfIndex of the port which would be performed single end loopback test.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

seltOps 1.3.6.1.4.1.890.1.5.11.1.8.2
The manager sets the object to 1 to start the selt and the agent clears the object to zero when selt is successfully completed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

seltStatus 1.3.6.1.4.1.890.1.5.11.1.8.3
Status description of the selt result.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

seltCableType 1.3.6.1.4.1.890.1.5.11.1.8.4
The cable type that selt result indicates.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER awg24(1), awg26(2)  

seltLoopEstimateLengthFt 1.3.6.1.4.1.890.1.5.11.1.8.5
The estimated loop length that selt result indicates.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

seltLoopEstimateLengthMeter 1.3.6.1.4.1.890.1.5.11.1.8.6
The estimated loop length that selt result indicates.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER