ZYXEL-IESCOMMON-MIB

File: ZYXEL-IESCOMMON-MIB.mib (75098 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
SNMPv2-TC Q-BRIDGE-MIB BRIDGE-MIB
ZYXEL-MIB

Imported symbols

OBJECT-TYPE IpAddress TRAP-TYPE
DisplayString ifIndex PhysAddress
RowStatus PortList MacAddress
Timeout BridgeId iesSeries
iesSeriesCommon

Defined Types

IesChassisEntry  
SEQUENCE    
  iesChassisId INTEGER
  iesChassisFrameNumber INTEGER
  iesChassisSerialNumber DisplayString
  iesChassisNumber INTEGER
  iesChassisStatus INTEGER

IesSlotEntry  
SEQUENCE    
  iesSlotId INTEGER
  iesSlotModuleType INTEGER
  iesSlotModuleDescr DisplayString
  iesSlotModuleFWVersion DisplayString
  iesSlotModuleDriverVersion DisplayString
  iesSlotModuleModemCodeVersion DisplayString
  iesSlotModuleStatus INTEGER
  iesSlotModuleAlarmStatus INTEGER

IesMscPortConfEntry  
SEQUENCE    
  iesMscPortId INTEGER
  iesMscPortType INTEGER
  iesMscPortIfIndex INTEGER
  iesMscPortSpeed INTEGER
  iesMscPortDuplex INTEGER
  iesMscPortFlowControl INTEGER
  iesMscPortDefaultVLANTagging INTEGER
  iesMscPortTrunkGroupId INTEGER
  iesMscPortMode INTEGER
  iesMscPortVLANTrunking INTEGER

IesFanRpmEntry  
SEQUENCE    
  iesFanRpmIndex INTEGER
  iesFanRpmCurValue INTEGER
  iesFanRpmMaxValue INTEGER
  iesFanRpmMinValue INTEGER
  iesFanRpmLowThresh INTEGER
  iesFanRpmDescr DisplayString

IesVoltageEntry  
SEQUENCE    
  iesVoltageIndex INTEGER
  iesVoltageCurValue INTEGER
  iesVoltageMaxValue INTEGER
  iesVoltageMinValue INTEGER
  iesVoltageNominalValue INTEGER
  iesVoltageLowThresh INTEGER
  iesVoltageDescr DisplayString

IesSysTempEntry  
SEQUENCE    
  iesSysTempIndex INTEGER
  iesSysTempCurValue INTEGER
  iesSysTempMaxValue INTEGER
  iesSysTempMinValue INTEGER
  iesSysTempHighThresh INTEGER
  iesSysTempDescr DisplayString

IesAccessCtrlEntry  
SEQUENCE    
  iesAccessCtrlService INTEGER
  iesAccessCtrlEnable INTEGER
  iesAccessCtrlPort INTEGER

IesSecuredClientEntry  
SEQUENCE    
  iesSecuredClientStartIp IpAddress
  iesSecuredClientEndIp IpAddress
  iesSecuredClientService INTEGER
  iesSecuredClientRowStatus RowStatus

IesStaticRouteEntry  
SEQUENCE    
  iesStaticRouteName DisplayString
  iesStaticRouteDest IpAddress
  iesStaticRouteMask IpAddress
  iesStaticRouteGateway IpAddress
  iesStaticRouteMetric INTEGER
  iesStaticRouteRowStatus RowStatus

IesDhcpServerEntry  
SEQUENCE    
  iesDhcpServerIp IpAddress
  iesDhcpServerRowStatus RowStatus

IesSNMPTrapDestEntry  
SEQUENCE    
  iesTrapDestIp IpAddress
  iesTrapDestPort INTEGER
  iesTrapDestRowStatus RowStatus

IesRadiusServerEntry  
SEQUENCE    
  iesRadiusServerIndex INTEGER
  iesRadiusServerIp IpAddress
  iesRadiusServerPort INTEGER
  iesRadiusSharedSecret DisplayString
  iesRadiusServerRowStatus RowStatus

IesDot1xPortEntry  
SEQUENCE    
  iesDot1xPortEnable INTEGER
  iesDot1xPortControl INTEGER
  iesDot1xPortReAuthEnable INTEGER
  iesDot1xPortReAuthPeriod INTEGER

IesMacFilterPortEntry  
SEQUENCE    
  iesMacFilterPortEnable INTEGER

IesMacFilterEntry  
SEQUENCE    
  iesMacFilterMacAddr PhysAddress
  iesMacFilterRowStatus RowStatus

IesMacFilterStatusEntry  
SEQUENCE    
  iesMacFilterStatusId INTEGER
  iesMacFilterStatusAddr PhysAddress

IesPacketFilterEntry  
SEQUENCE    
  iesPacketFilter INTEGER

IesMacCountFilterEntry  
SEQUENCE    
  iesMacCountFilterStatus INTEGER
  iesMacCountFilterCount INTEGER

IesMulticastGroupEntry  
SEQUENCE    
  iesMulticastGroupMacAddr PhysAddress
  iesMulticastGroupPorts PortList
  iesMulticastGroupRowStatus RowStatus

IesIgmpFilterEntry  
SEQUENCE    
  iesIgmpFilterName OCTET STRING
  iesIgmpFilterIndex INTEGER
  iesIgmpFilterStartIp IpAddress
  iesIgmpFilterEndIp IpAddress
  iesIgmpFilterRowStatus RowStatus

IesIgmpFilterPortEntry  
SEQUENCE    
  iesIgmpFilterPortFilter OCTET STRING

IesTrunkGroupEntry  
SEQUENCE    
  iesTrunkGroupId INTEGER
  iesTrunkGroupName DisplayString
  iesTrunkGroupPorts PortList
  iesTrunkGroupRowStatus RowStatus

IesMacEntry  
SEQUENCE    
  iesMacAddress MacAddress
  iesMacPort INTEGER
  iesMacStatus INTEGER

Defined Values

iesChassis 1.3.6.1.4.1.890.1.5.13.1.1
OBJECT IDENTIFIER    

iesHWMonitor 1.3.6.1.4.1.890.1.5.13.1.2
OBJECT IDENTIFIER    

iesSysMgnt 1.3.6.1.4.1.890.1.5.13.1.3
OBJECT IDENTIFIER    

iesSysState 1.3.6.1.4.1.890.1.5.13.1.3.1
OBJECT IDENTIFIER    

iesSysMaintenance 1.3.6.1.4.1.890.1.5.13.1.3.2
OBJECT IDENTIFIER    

iesSysTimeSetup 1.3.6.1.4.1.890.1.5.13.1.3.3
OBJECT IDENTIFIER    

iesSysAccessControl 1.3.6.1.4.1.890.1.5.13.1.3.4
OBJECT IDENTIFIER    

iesSysStaticRoute 1.3.6.1.4.1.890.1.5.13.1.3.5
OBJECT IDENTIFIER    

iesSyslogSetup 1.3.6.1.4.1.890.1.5.13.1.3.6
OBJECT IDENTIFIER    

iesSysDhcpSetup 1.3.6.1.4.1.890.1.5.13.1.3.7
OBJECT IDENTIFIER    

iesSysSNMPSetup 1.3.6.1.4.1.890.1.5.13.1.3.8
OBJECT IDENTIFIER    

iesSysDot1xSetup 1.3.6.1.4.1.890.1.5.13.1.3.9
OBJECT IDENTIFIER    

iesSysMacFilter 1.3.6.1.4.1.890.1.5.13.1.3.10
OBJECT IDENTIFIER    

iesSysPacketFilter 1.3.6.1.4.1.890.1.5.13.1.3.11
OBJECT IDENTIFIER    

iesSysMacCountFilter 1.3.6.1.4.1.890.1.5.13.1.3.12
OBJECT IDENTIFIER    

iesSysMulticastGroup 1.3.6.1.4.1.890.1.5.13.1.3.13
OBJECT IDENTIFIER    

iesSysIgmpFilter 1.3.6.1.4.1.890.1.5.13.1.3.14
OBJECT IDENTIFIER    

iesL2SW 1.3.6.1.4.1.890.1.5.13.1.4
OBJECT IDENTIFIER    

iesStats 1.3.6.1.4.1.890.1.5.13.1.5
OBJECT IDENTIFIER    

iesMacStats 1.3.6.1.4.1.890.1.5.13.1.5.1
OBJECT IDENTIFIER    

iesNumOfChassis 1.3.6.1.4.1.890.1.5.13.1.1.1
The number of chassis in the IES-2000/3000 system
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesChassisTable 1.3.6.1.4.1.890.1.5.13.1.1.2
The table which contains the chassis information in IES-2000/3000 system
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesChassisEntry

iesChassisEntry 1.3.6.1.4.1.890.1.5.13.1.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesChassisEntry  

iesChassisId 1.3.6.1.4.1.890.1.5.13.1.1.2.1.1
The Chassis ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesChassisFrameNumber 1.3.6.1.4.1.890.1.5.13.1.1.2.1.2
The Frame ID
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesChassisSerialNumber 1.3.6.1.4.1.890.1.5.13.1.1.2.1.3
The Chassis Serial Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesChassisNumber 1.3.6.1.4.1.890.1.5.13.1.1.2.1.4
The Chassis Number which is defined by the system administrator for management purpose
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesChassisStatus 1.3.6.1.4.1.890.1.5.13.1.1.2.1.5
The current status of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), up(2), down(3), testing(4)  

iesSlotTable 1.3.6.1.4.1.890.1.5.13.1.1.3
The table which contains the slot information in a chassis of IES-2000/3000 system
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesSlotEntry

iesSlotEntry 1.3.6.1.4.1.890.1.5.13.1.1.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesSlotEntry  

iesSlotId 1.3.6.1.4.1.890.1.5.13.1.1.3.1.1
Identity of the slot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSlotModuleType 1.3.6.1.4.1.890.1.5.13.1.1.3.1.2
Card type of the plug-in card in IES-2000/3000.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), msc1000-L2(2), msc1000-ML(3), alc1024-61(4), vlc1012(5), slc1024(6), alc1024-63(7), msc1000A(8), vlc1124(9), alc1224-71(10), alc1224-73(11), slc1224-22(12), alc1224-51(13), alc1224-53(14)  

iesSlotModuleDescr 1.3.6.1.4.1.890.1.5.13.1.1.3.1.3
The descriptions of the plug-in card in IES-2000/3000.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesSlotModuleFWVersion 1.3.6.1.4.1.890.1.5.13.1.1.3.1.4
The firmware version of the plug-in card in IES-2000/3000.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesSlotModuleDriverVersion 1.3.6.1.4.1.890.1.5.13.1.1.3.1.5
The DSL driver of the plug-in card in IES-2000/3000.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesSlotModuleModemCodeVersion 1.3.6.1.4.1.890.1.5.13.1.1.3.1.6
The DSL modem code version of the plug-in card in IES-2000/3000
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesSlotModuleStatus 1.3.6.1.4.1.890.1.5.13.1.1.3.1.7
The module state of the plug-in card in IES-2000/3000
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), up(2), down(3), testing(4), standby(5)  

iesSlotModuleAlarmStatus 1.3.6.1.4.1.890.1.5.13.1.1.3.1.8
This variable indicates the alarm status of the module. It is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The moduleNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 moduleNoDefect 2 moduleOverHeat 3 moduleFanRpmLow 4 moduleVoltageLow 5 moduleThermalSensorFailure 6 modulePullOut 7 powerDC48VAFailure 8 powerDC48VBFailure 9 extAlarmInputTrigger 10 moduleDown 11 mscSwitchOverOK 12 networkTopologyChange
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

iesMscPortConfTable 1.3.6.1.4.1.890.1.5.13.1.1.4
The table contains port configuration information in MSC1000.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesMscPortConfEntry

iesMscPortConfEntry 1.3.6.1.4.1.890.1.5.13.1.1.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesMscPortConfEntry  

iesMscPortId 1.3.6.1.4.1.890.1.5.13.1.1.4.1.1
Identity of the extension slot in MSC1000.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMscPortType 1.3.6.1.4.1.890.1.5.13.1.1.4.1.2
Port type of the extension slot in MSC1000.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), e1000BaseT(2), e1000BaseLX(3), e1000BaseSX(4), e100BaseFX(5), e100BaseTX(6), e1000BaseGBIC(7)  

iesMscPortIfIndex 1.3.6.1.4.1.890.1.5.13.1.1.4.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMscPortSpeed 1.3.6.1.4.1.890.1.5.13.1.1.4.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), e1000M(2), e100M(3), e10M(4)  

iesMscPortDuplex 1.3.6.1.4.1.890.1.5.13.1.1.4.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), half(2)  

iesMscPortFlowControl 1.3.6.1.4.1.890.1.5.13.1.1.4.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

iesMscPortDefaultVLANTagging 1.3.6.1.4.1.890.1.5.13.1.1.4.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

iesMscPortTrunkGroupId 1.3.6.1.4.1.890.1.5.13.1.1.4.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMscPortMode 1.3.6.1.4.1.890.1.5.13.1.1.4.1.9
The operational mode for uplink and subtending ports in MSC. Only the operational mode of subtending ports can be modified.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER uplink(1), subtending(2)  

iesMscPortVLANTrunking 1.3.6.1.4.1.890.1.5.13.1.1.4.1.10
The VLAN trunking setting for uplink and subtending ports in MSC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesFanRpmTable 1.3.6.1.4.1.890.1.5.13.1.2.1
A table that contains rpm information about the fans.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesFanRpmEntry

iesFanRpmEntry 1.3.6.1.4.1.890.1.5.13.1.2.1.1
A list of rpm information for each fan.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesFanRpmEntry  

iesFanRpmIndex 1.3.6.1.4.1.890.1.5.13.1.2.1.1.1
The identity of the fan.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesFanRpmCurValue 1.3.6.1.4.1.890.1.5.13.1.2.1.1.2
The current rpm of the fan.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesFanRpmMaxValue 1.3.6.1.4.1.890.1.5.13.1.2.1.1.3
The maximum rpm ever performed by the fan.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesFanRpmMinValue 1.3.6.1.4.1.890.1.5.13.1.2.1.1.4
The minimum rpm ever performed by the fan.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesFanRpmLowThresh 1.3.6.1.4.1.890.1.5.13.1.2.1.1.5
The low threshold of the rpm of the fan. If the current rpm is less than the threshold, the device will initiate the fanRpmLow trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesFanRpmDescr 1.3.6.1.4.1.890.1.5.13.1.2.1.1.6
The description of the fan (e.g. location, function, etc.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesVoltageTable 1.3.6.1.4.1.890.1.5.13.1.2.2
A table that contains voltage information about the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesVoltageEntry

iesVoltageEntry 1.3.6.1.4.1.890.1.5.13.1.2.2.1
A list of voltage information for each sensor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesVoltageEntry  

iesVoltageIndex 1.3.6.1.4.1.890.1.5.13.1.2.2.1.1
The identity of the sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesVoltageCurValue 1.3.6.1.4.1.890.1.5.13.1.2.2.1.2
The current voltage detected by the sensor (in milli-voltage).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesVoltageMaxValue 1.3.6.1.4.1.890.1.5.13.1.2.2.1.3
The maximum voltage ever detected by the sensor (in milli-voltage).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesVoltageMinValue 1.3.6.1.4.1.890.1.5.13.1.2.2.1.4
The minimum voltage ever detected by the sensor (in milli-voltage).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesVoltageNominalValue 1.3.6.1.4.1.890.1.5.13.1.2.2.1.5
The nominal voltage which the power should supply (in milli-voltage).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesVoltageLowThresh 1.3.6.1.4.1.890.1.5.13.1.2.2.1.6
The low threshold of the voltage (in milli-voltage). If the current voltage is less than the threshold, the device will initiate the voltageLow trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesVoltageDescr 1.3.6.1.4.1.890.1.5.13.1.2.2.1.7
The description of the voltage (e.g. location, nominal value, etc.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesSysTempTable 1.3.6.1.4.1.890.1.5.13.1.2.3
A table that contains temperature information about system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesSysTempEntry

iesSysTempEntry 1.3.6.1.4.1.890.1.5.13.1.2.3.1
A list of temperature information for each sensor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesSysTempEntry  

iesSysTempIndex 1.3.6.1.4.1.890.1.5.13.1.2.3.1.1
The identity of the sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSysTempCurValue 1.3.6.1.4.1.890.1.5.13.1.2.3.1.2
The current temperature detected in Celsius by the sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSysTempMaxValue 1.3.6.1.4.1.890.1.5.13.1.2.3.1.3
The maximum temperature ever detected in Celsius by the sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSysTempMinValue 1.3.6.1.4.1.890.1.5.13.1.2.3.1.4
The minimum temperature ever detected in Celsius by the sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSysTempHighThresh 1.3.6.1.4.1.890.1.5.13.1.2.3.1.5
The high threshold of the temperature in Celsius. If the current temperature is higher than the threshold, the device will initiate the overheat trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSysTempDescr 1.3.6.1.4.1.890.1.5.13.1.2.3.1.6
The description of the temperature sensor (e.g. location, function, etc.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesSystemCurrentStatus 1.3.6.1.4.1.890.1.5.13.1.3.1.1
This variable indicates the status of the system. The sysCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sysNoDefect 2 sysTemperatureAbnormal 3 sysFanRpmAbnormal 4 sysVoltageAbnormal 5 sysThermalSensorFailure 6 modulePullOut 7 powerDC48VAFailure 8 powerDC48VBFailure 9 extAlarmInputTrigger 10 moduleDown 11 mscSwitchOverOK 12 networkTopologyChange
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

iesProblemCause 1.3.6.1.4.1.890.1.5.13.1.3.1.2
It describes the problem occurred in the system, e.g. maintenance operation failures, system reboot, error log, ...etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesMaintenanceOps 1.3.6.1.4.1.890.1.5.13.1.3.2.1
The managed object is for system maintenance. When the EMS wants to trigger the system maitenance operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: config save BIT 2: reset BIT 3: local loopback test BIT 4: remote loopback test BIT 5: clear system alarms BIT 6: F4 loopback test BIT 7: F5 loopback test BIT 8: DSL Line Diagnostic
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaintenanceTarget 1.3.6.1.4.1.890.1.5.13.1.3.2.2
The managed object is used for identify the target on which the maintenance operation should be performed. The target can be a chassis, a plug-in module, and a port. The value of the object will be: (Chassis_id * 10000 + slot_id * 100 + port_id) where chassis_id: 0~3, slot_id: 1~16, port_id: 1~24
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaintenanceDSLConfOps 1.3.6.1.4.1.890.1.5.13.1.3.2.3
The managed object is for xDSL line configuration. When the EMS wants to issue the desired operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: enable port BIT 2: disable port BIT 3: set DSL mode BIT 4: set profile BIT 5: enable mac filter BIT 6: disable mac filter BIT 7: set packet filter BIT 8: enable dot1x BIT 9: disable dot1x BIT 10: set dot1x control BIT 11: enable dot1x re-authentication BIT 12: disable dot1x re-authentication BIT 13: set dot1x re-authentication period BIT 14: enable mac count filter BIT 15: disable mac count filter BIT 16: set mac count filter BIT 17: set alarm profile BIT 18: set Annex L (Only in AnnexA) BIT 19: set power management BIT 20: set rate adaptation mode BIT 21: set IGMP filter BIT 22: enable Annex M BIT 23: disable Annex M
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaintenanceDSLConfTarget 1.3.6.1.4.1.890.1.5.13.1.3.2.4
The managed object is used for identify the target on which the line configuration should be performed. The target is encoded as: Byte 1: the octet specifies a set of eight Chassis, Chassis 0 through 7 Byte 2~3: each octet specifies a set of eight slots, with the first octet specifying slots 1 through 8 and the second octet specifying slots 9 through 16. Byte 4: reserved Byte 5~11: each octet specifies a set of eight ports, with the first octet specifying ports 1 through 8, etc.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

iesMaintenanceDSLConfProfileName 1.3.6.1.4.1.890.1.5.13.1.3.2.5
The DSL profile name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..31)  

iesMaintenanceDSLConfMode 1.3.6.1.4.1.890.1.5.13.1.3.2.6
The DSL mode. The semantic for each bit is: Bit 1: ADSL, G.lite Bit 2: ADSL, G.dmt Bit 3: ADSL, T1.413 Bit 4: ADSL, Auto Bit 5: ADSL, ETSI Bit 6: ADSL2, Bit 7: ADSL2+
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaintenanceDSLConfPktFilter 1.3.6.1.4.1.890.1.5.13.1.3.2.7
The packet filter. The semantic for each bit is: Bit 1: accept all Bit 2: accept PPPoE only Bit 3: reject ARP Bit 4: reject DHCP Bit 5: reject EAPOL Bit 6: reject PPPoE Bit 7: reject NetBIOS Bit 8: reject IGMP Bit 9: reject IP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaintenanceDSLConfDot1xControl 1.3.6.1.4.1.890.1.5.13.1.3.2.8
The configuration defines the 802.1x control type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), forceAuth(2), forceUnAuth(3)  

iesMaintenanceDSLConfDot1xReauthPeriod 1.3.6.1.4.1.890.1.5.13.1.3.2.9
The configuration defines the 802.1x re-authentication period (seconds).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaintenanceDSLConfMacCount 1.3.6.1.4.1.890.1.5.13.1.3.2.10
The configuration defines the number of mac addresses which can pass through the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaintenanceVpi 1.3.6.1.4.1.890.1.5.13.1.3.2.11
VPI of the channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

iesMaintenanceVci 1.3.6.1.4.1.890.1.5.13.1.3.2.12
VCI of the channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

iesMaintenanceDSLConfAlarmProfileName 1.3.6.1.4.1.890.1.5.13.1.3.2.13
The DSL alarm profile name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

iesMaintenanceDSLConfAnnexL 1.3.6.1.4.1.890.1.5.13.1.3.2.14
The annex L setting of the ADSL line (Only in AnnexA).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableNarrowMode(1), enableWideMode(2), disable(3)  

iesMaintenanceDSLConfPmMode 1.3.6.1.4.1.890.1.5.13.1.3.2.15
The power management mode of the ADSL line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableL2Mode(1), enableL3Mode(2), disable(3)  

iesMaintenanceDSLConfRateMode 1.3.6.1.4.1.890.1.5.13.1.3.2.16
Defines what form of transmit rate adaptation is configured on this modem. See ADSL Forum TR-005 [3] for more information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixed(1), adaptAtStartup(2), adaptAtRuntime(3)  

iesMaintenanceDSLConfIgmpFilter 1.3.6.1.4.1.890.1.5.13.1.3.2.17
The IGMP filter name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

iesTimeServerMode 1.3.6.1.4.1.890.1.5.13.1.3.3.1
The mechanism of Time Server when the system boots up.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), daytime(2), time(3), ntp(4)  

iesTimeServerIP 1.3.6.1.4.1.890.1.5.13.1.3.3.2
The IP Address of Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

iesSystemTime 1.3.6.1.4.1.890.1.5.13.1.3.3.3
The system time
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

iesSystemDate 1.3.6.1.4.1.890.1.5.13.1.3.3.4
The system date
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

iesSystemTimeZone 1.3.6.1.4.1.890.1.5.13.1.3.3.5
The system time zone
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER utc-1200(1), utc-1100(2), utc-1000(3), utc-0900(4), utc-0800(5), utc-0700(6), utc-0600(7), utc-0500(8), utc-0400(9), utc-0300(10), utc-0200(11), utc-0100(12), utc(13), utc0100(14), utc0200(15), utc0300(16), utc0400(17), utc0500(18), utc0600(19), utc0700(20), utc0800(21), utc0900(22), utc1000(23), utc1100(24), utc1200(25)  

iesAccessCtrlTable 1.3.6.1.4.1.890.1.5.13.1.3.4.1
A table that contains information about service access control.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesAccessCtrlEntry

iesAccessCtrlEntry 1.3.6.1.4.1.890.1.5.13.1.3.4.1.1
A list of access control entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesAccessCtrlEntry  

iesAccessCtrlService 1.3.6.1.4.1.890.1.5.13.1.3.4.1.1.1
The service type of the access control entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER telnet(1), ftp(2), web(3), icmp(4)  

iesAccessCtrlEnable 1.3.6.1.4.1.890.1.5.13.1.3.4.1.1.2
Enable or disable the service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesAccessCtrlPort 1.3.6.1.4.1.890.1.5.13.1.3.4.1.1.3
The port number which the service uses.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaxNumOfSecuredClients 1.3.6.1.4.1.890.1.5.13.1.3.4.2
The maximum number of sets of secured clients.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSecuredClientTable 1.3.6.1.4.1.890.1.5.13.1.3.4.3
A table that contains information about secured clients.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesSecuredClientEntry

iesSecuredClientEntry 1.3.6.1.4.1.890.1.5.13.1.3.4.3.1
A list of secured client entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesSecuredClientEntry  

iesSecuredClientStartIp 1.3.6.1.4.1.890.1.5.13.1.3.4.3.1.1
The starting IP address of a set of secured clients.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

iesSecuredClientEndIp 1.3.6.1.4.1.890.1.5.13.1.3.4.3.1.2
The ending IP address of a set of secured clients.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

iesSecuredClientService 1.3.6.1.4.1.890.1.5.13.1.3.4.3.1.3
Each bit corresponds to a service. The bit is set to 1 if the service is enabled, and set to 0 if the service is disabled. The various bit positions are: BIT 1: telnet BIT 2: FTP BIT 3: web BIT 4: ICMP
Status: mandatory Access: read-create
OBJECT-TYPE    
  INTEGER  

iesSecuredClientRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.4.3.1.4
This object is used to create a new row or modify or delete an existing row in this table. A row is activated by setting this object to `active', and is deactivated by setting it to 'notInService'.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesMaxNumOfStaticRoutes 1.3.6.1.4.1.890.1.5.13.1.3.5.1
The maximum number of static routes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesStaticRouteTable 1.3.6.1.4.1.890.1.5.13.1.3.5.2
A table that contains information about static routes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesStaticRouteEntry

iesStaticRouteEntry 1.3.6.1.4.1.890.1.5.13.1.3.5.2.1
A list of static route entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesStaticRouteEntry  

iesStaticRouteName 1.3.6.1.4.1.890.1.5.13.1.3.5.2.1.1
The name of the static route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

iesStaticRouteDest 1.3.6.1.4.1.890.1.5.13.1.3.5.2.1.2
The destination IP address of the static route.
Status: mandatory Access: read-create
OBJECT-TYPE    
  IpAddress  

iesStaticRouteMask 1.3.6.1.4.1.890.1.5.13.1.3.5.2.1.3
The subnet mask of the static route.
Status: mandatory Access: read-create
OBJECT-TYPE    
  IpAddress  

iesStaticRouteGateway 1.3.6.1.4.1.890.1.5.13.1.3.5.2.1.4
The gateway IP address of the static route.
Status: mandatory Access: read-create
OBJECT-TYPE    
  IpAddress  

iesStaticRouteMetric 1.3.6.1.4.1.890.1.5.13.1.3.5.2.1.5
The routing metric of the static route.
Status: mandatory Access: read-create
OBJECT-TYPE    
  INTEGER  

iesStaticRouteRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.5.2.1.6
This object is used to create a new row or modify or delete an existing row in this table. A row is activated by setting this object to `active', and is deactivated by setting it to 'notInService'.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesSysLogEnable 1.3.6.1.4.1.890.1.5.13.1.3.6.1
Enable/disable syslog function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesSysLogServer 1.3.6.1.4.1.890.1.5.13.1.3.6.2
IP address of the syslog server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

iesSysLogFacility 1.3.6.1.4.1.890.1.5.13.1.3.6.3
Log facility used by the syslog function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local1(1), local2(2), local3(3), local4(4), local5(5), local6(6), local7(7)  

iesDhcpRelayEnable 1.3.6.1.4.1.890.1.5.13.1.3.7.1
Enable/disable DHCP relay function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesDhcpRelayOption82Enable 1.3.6.1.4.1.890.1.5.13.1.3.7.2
Enable/disable DHCP relay Option82 function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesDhcpRelayOption82Info 1.3.6.1.4.1.890.1.5.13.1.3.7.3
User specific Option82 information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

iesMaxNumOfDhcpServers 1.3.6.1.4.1.890.1.5.13.1.3.7.4
The maximum number of DHCP servers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesDhcpServerTable 1.3.6.1.4.1.890.1.5.13.1.3.7.5
A table that contains DHCP server information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesDhcpServerEntry

iesDhcpServerEntry 1.3.6.1.4.1.890.1.5.13.1.3.7.5.1
The entry of DHCP server table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesDhcpServerEntry  

iesDhcpServerIp 1.3.6.1.4.1.890.1.5.13.1.3.7.5.1.1
The IP address of the DHCP server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

iesDhcpServerRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.7.5.1.2
The row status of the DHCP server entry.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesMaxNumberOfTrapDestinations 1.3.6.1.4.1.890.1.5.13.1.3.8.1
The max number of the trap destinations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesSNMPTrapDestTable 1.3.6.1.4.1.890.1.5.13.1.3.8.2
A table that contains SNMP trap destination information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesSNMPTrapDestEntry

iesSNMPTrapDestEntry 1.3.6.1.4.1.890.1.5.13.1.3.8.2.1
The entry of SNMP trap destination table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesSNMPTrapDestEntry  

iesTrapDestIp 1.3.6.1.4.1.890.1.5.13.1.3.8.2.1.1
The IP address of the trap destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

iesTrapDestPort 1.3.6.1.4.1.890.1.5.13.1.3.8.2.1.2
The UDP port of the trap destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesTrapDestRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.8.2.1.3
The row status of the trap destination entry.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesSnmpGetCommunity 1.3.6.1.4.1.890.1.5.13.1.3.8.3
The SNMP get community.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

iesSnmpSetCommunity 1.3.6.1.4.1.890.1.5.13.1.3.8.4
The SNMP set community.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

iesSnmpTrapCommunity 1.3.6.1.4.1.890.1.5.13.1.3.8.5
The SNMP trap community.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

iesMaxNumberOfRadiusServers 1.3.6.1.4.1.890.1.5.13.1.3.9.1
The max number of the RADIUS Servers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesRadiusServerTable 1.3.6.1.4.1.890.1.5.13.1.3.9.2
A table that contains Radius Server information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesRadiusServerEntry

iesRadiusServerEntry 1.3.6.1.4.1.890.1.5.13.1.3.9.2.1
The entry of Radius Server table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesRadiusServerEntry  

iesRadiusServerIndex 1.3.6.1.4.1.890.1.5.13.1.3.9.2.1.1
The identity of the RADIUS server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesRadiusServerIp 1.3.6.1.4.1.890.1.5.13.1.3.9.2.1.2
The IP address of the Radius Server.
Status: mandatory Access: read-create
OBJECT-TYPE    
  IpAddress  

iesRadiusServerPort 1.3.6.1.4.1.890.1.5.13.1.3.9.2.1.3
The UDP port of the Radius Server.
Status: mandatory Access: read-create
OBJECT-TYPE    
  INTEGER  

iesRadiusSharedSecret 1.3.6.1.4.1.890.1.5.13.1.3.9.2.1.4
The shared secret of the Radius Server.
Status: mandatory Access: read-create
OBJECT-TYPE    
  DisplayString  

iesRadiusServerRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.9.2.1.5
The row status of the Radius Server entry.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesDot1xEnable 1.3.6.1.4.1.890.1.5.13.1.3.9.3
Enable/disable the 802.1x function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesDot1xPortTable 1.3.6.1.4.1.890.1.5.13.1.3.9.4
This table includes the configuration of 802.1x.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesDot1xPortEntry

iesDot1xPortEntry 1.3.6.1.4.1.890.1.5.13.1.3.9.4.1
An entry in iesDot1xPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesDot1xPortEntry  

iesDot1xPortEnable 1.3.6.1.4.1.890.1.5.13.1.3.9.4.1.1
The option defines if the port enables 802.1x settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesDot1xPortControl 1.3.6.1.4.1.890.1.5.13.1.3.9.4.1.2
The configuration defines the 802.1x port control type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), forceAuth(2), forceUnAuth(3)  

iesDot1xPortReAuthEnable 1.3.6.1.4.1.890.1.5.13.1.3.9.4.1.3
The option defines if the port enables 802.1x re-authentication.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

iesDot1xPortReAuthPeriod 1.3.6.1.4.1.890.1.5.13.1.3.9.4.1.4
The configuration defines the 802.1x re-authentication period (seconds) for each port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMacFilterPortTable 1.3.6.1.4.1.890.1.5.13.1.3.10.1
This table includes the status of mac filtering for each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesMacFilterPortEntry

iesMacFilterPortEntry 1.3.6.1.4.1.890.1.5.13.1.3.10.1.1
An entry in iesMacFilterPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesMacFilterPortEntry  

iesMacFilterPortEnable 1.3.6.1.4.1.890.1.5.13.1.3.10.1.1.1
The option defines if the port enables mac filtering.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable-accept(1), disable(2), enable-deny(3)  

iesMaxNumberOfMacFilters 1.3.6.1.4.1.890.1.5.13.1.3.10.2
The max number of the mac filters in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMaxNumberOfMacFiltersPerPort 1.3.6.1.4.1.890.1.5.13.1.3.10.3
The max number of the mac filters for each port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesCurrNumberOfMacFilters 1.3.6.1.4.1.890.1.5.13.1.3.10.4
The current number of the mac filters in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMacFilterTable 1.3.6.1.4.1.890.1.5.13.1.3.10.5
A table that contains the mac filtering information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesMacFilterEntry

iesMacFilterEntry 1.3.6.1.4.1.890.1.5.13.1.3.10.5.1
The entry of iesMacFilterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesMacFilterEntry  

iesMacFilterMacAddr 1.3.6.1.4.1.890.1.5.13.1.3.10.5.1.1
The mac address which can pass through the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

iesMacFilterRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.10.5.1.2
The row status of the entry.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesMacFilterStatusTable 1.3.6.1.4.1.890.1.5.13.1.3.10.6
A table that contains the mac filter addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesMacFilterStatusEntry

iesMacFilterStatusEntry 1.3.6.1.4.1.890.1.5.13.1.3.10.6.1
The entry of iesMacFilterStatusTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesMacFilterStatusEntry  

iesMacFilterStatusId 1.3.6.1.4.1.890.1.5.13.1.3.10.6.1.1
The index of the entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMacFilterStatusAddr 1.3.6.1.4.1.890.1.5.13.1.3.10.6.1.2
The mac address which can pass through or be rejected from the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

iesPacketFilterTable 1.3.6.1.4.1.890.1.5.13.1.3.11.1
This table includes packet filtering for each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesPacketFilterEntry

iesPacketFilterEntry 1.3.6.1.4.1.890.1.5.13.1.3.11.1.1
An entry in iesPacketFilterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesPacketFilterEntry  

iesPacketFilter 1.3.6.1.4.1.890.1.5.13.1.3.11.1.1.1
The packet filter. The semantic for each bit is: Bit 1: accept all Bit 2: accept PPPoE only Bit 3: reject ARP Bit 4: reject DHCP Bit 5: reject EAPOL Bit 6: reject PPPoE Bit 7: reject NetBIOS Bit 8: reject IGMP Bit 9: reject IP
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMacCountFilterTable 1.3.6.1.4.1.890.1.5.13.1.3.12.1
This table includes mac count filtering for each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesMacCountFilterEntry

iesMacCountFilterEntry 1.3.6.1.4.1.890.1.5.13.1.3.12.1.1
An entry in iesMacCountFilterTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesMacCountFilterEntry  

iesMacCountFilterStatus 1.3.6.1.4.1.890.1.5.13.1.3.12.1.1.1
The option defines if the port enables mac count filtering.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesMacCountFilterCount 1.3.6.1.4.1.890.1.5.13.1.3.12.1.1.2
The number of mac addresses which can pass through the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaxNumberOfMulticastGroups 1.3.6.1.4.1.890.1.5.13.1.3.13.1
The max number of static multicast groups in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMulticastGroupTable 1.3.6.1.4.1.890.1.5.13.1.3.13.2
A table that contains static multicast group information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesMulticastGroupEntry

iesMulticastGroupEntry 1.3.6.1.4.1.890.1.5.13.1.3.13.2.1
The entry of multicast group table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesMulticastGroupEntry  

iesMulticastGroupMacAddr 1.3.6.1.4.1.890.1.5.13.1.3.13.2.1.1
The multicast MAC address of the group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

iesMulticastGroupPorts 1.3.6.1.4.1.890.1.5.13.1.3.13.2.1.2
The port list which specifies the ports joining the multicast group.
Status: mandatory Access: read-create
OBJECT-TYPE    
  PortList  

iesMulticastGroupRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.13.2.1.3
The row status of the multicast group entry.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesMaxNumberOfIgmpFilters 1.3.6.1.4.1.890.1.5.13.1.3.14.1
The max number of IGMP filters in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesIgmpFilterTable 1.3.6.1.4.1.890.1.5.13.1.3.14.2
A table that contains IGMP filters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesIgmpFilterEntry

iesIgmpFilterEntry 1.3.6.1.4.1.890.1.5.13.1.3.14.2.1
The entry of IGMP filter table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesIgmpFilterEntry  

iesIgmpFilterName 1.3.6.1.4.1.890.1.5.13.1.3.14.2.1.1
The IGMP filter name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

iesIgmpFilterIndex 1.3.6.1.4.1.890.1.5.13.1.3.14.2.1.2
The index which specifies the filter rule.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesIgmpFilterStartIp 1.3.6.1.4.1.890.1.5.13.1.3.14.2.1.3
The start IP of the filter rule.
Status: mandatory Access: read-create
OBJECT-TYPE    
  IpAddress  

iesIgmpFilterEndIp 1.3.6.1.4.1.890.1.5.13.1.3.14.2.1.4
The end IP of the filter rule.
Status: mandatory Access: read-create
OBJECT-TYPE    
  IpAddress  

iesIgmpFilterRowStatus 1.3.6.1.4.1.890.1.5.13.1.3.14.2.1.5
The row status of the IGMP filter entry.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesIgmpFilterPortTable 1.3.6.1.4.1.890.1.5.13.1.3.14.3
This table specifies the IGMP filter of the port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesIgmpFilterPortEntry

iesIgmpFilterPortEntry 1.3.6.1.4.1.890.1.5.13.1.3.14.3.1
An entry in iesIgmpFilterPortTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesIgmpFilterPortEntry  

iesIgmpFilterPortFilter 1.3.6.1.4.1.890.1.5.13.1.3.14.3.1.1
The IGMP filter of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

iesIGMPSnoopingEnabled 1.3.6.1.4.1.890.1.5.13.1.4.1
A flag indicating whether IGMP snooping function is enabled or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

iesManagementVLANId 1.3.6.1.4.1.890.1.5.13.1.4.2
The VLAN ID for management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMaxNumOfStaticVlans 1.3.6.1.4.1.890.1.5.13.1.4.3
The maximum number of static VLANs supported by the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesPortIsolationEnable 1.3.6.1.4.1.890.1.5.13.1.4.6
A flag indicating whether VLAN port isolation function is enabled or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesRSTPEnable 1.3.6.1.4.1.890.1.5.13.1.4.7
Enable/Disable RSTP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

iesSwitchMode 1.3.6.1.4.1.890.1.5.13.1.4.8
Switch DSLAM's operatrion Mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER daisy-chain(1), standalone(2)  

iesMaxNumOfTrunkGroups 1.3.6.1.4.1.890.1.5.13.1.4.4
The maximum number of trunk groups.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesTrunkGroupTable 1.3.6.1.4.1.890.1.5.13.1.4.5
A table that contains trunk group configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesTrunkGroupEntry

iesTrunkGroupEntry 1.3.6.1.4.1.890.1.5.13.1.4.5.1
The entry of trunk group table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesTrunkGroupEntry  

iesTrunkGroupId 1.3.6.1.4.1.890.1.5.13.1.4.5.1.1
The ID of the trunk group
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesTrunkGroupName 1.3.6.1.4.1.890.1.5.13.1.4.5.1.2
The name of the trunk group
Status: mandatory Access: read-create
OBJECT-TYPE    
  DisplayString  

iesTrunkGroupPorts 1.3.6.1.4.1.890.1.5.13.1.4.5.1.3
The port list of the trunk group
Status: mandatory Access: read-create
OBJECT-TYPE    
  PortList  

iesTrunkGroupRowStatus 1.3.6.1.4.1.890.1.5.13.1.4.5.1.4
The row status of the trunk group entry
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

iesMacDisplayTarget 1.3.6.1.4.1.890.1.5.13.1.5.1.1
This managed object is a filter used for identify the target from which the MAC addresses are learned in macTable. The target could be: 1: Subtending port 1 2: Subtending port 2 3: Uplink port 1 4: Uplink port 2 5: All of the four uplink ports 6: All ports in the system IfIndex is used for identifying subscriber ports (e.g. 300 means all ports in slot 3 and 301 means port 1 in slot 3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

iesMacTable 1.3.6.1.4.1.890.1.5.13.1.5.1.2
A table that contains information about unicast entries for which the bridge has forwarding and/or filtering information. This information is used by the transparent bridging function in determining how to propagate a received frame.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IesMacEntry

iesMacEntry 1.3.6.1.4.1.890.1.5.13.1.5.1.2.1
An entry of iesMacTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IesMacEntry  

iesMacAddress 1.3.6.1.4.1.890.1.5.13.1.5.1.2.1.1
A unicast MAC address for which the bridge has forwarding and/or filtering information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

iesMacPort 1.3.6.1.4.1.890.1.5.13.1.5.1.2.1.2
The port from which the mac address has been learned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iesMacStatus 1.3.6.1.4.1.890.1.5.13.1.5.1.2.1.3
The status of this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), invalid(2), learned(3), self(4), mgmt(5)  

reboot 1
Send a message to the manager that the system is going to reboot. The variable is the reason why the system reboots.
TRAP-TYPE    

systemShutdown 2
Send a message to the manager that the system is going to shutdown. The variable is the reason that causes the system to shutdown.
TRAP-TYPE    

overheat 3
Send a message to the manager that the system is overheated. The variable in the binding list is the current temperature in Celsius of the system.
TRAP-TYPE    

overheatOver 4
Send a message to the manager that the overheated condition is over. The variable in the binding list is the current temperature in Celsius of the system.
TRAP-TYPE    

errLog 5
Send a message to the manager that an error log is created in system. The variable in the binding list is the content of the error log.
TRAP-TYPE    

fanRpmLow 6
Send a message to the manager that the rpm of the fan is too low. The variable in the binding list is the current rpm of the fan.
TRAP-TYPE    

fanRpmNormal 7
Send a message to the manager that the low-rpm condition of the fan is over. The variable in the binding list is the current rpm of the fan.
TRAP-TYPE    

voltageOutOfRange 8
Send a message to the manager that the voltage of the system is out of range. The variable in the binding list is the current voltage in volt of the system.
TRAP-TYPE    

voltageNormal 9
Send a message to the manager that the low-voltage condition is over. The variable in the binding list is the current voltage in volt of the system.
TRAP-TYPE    

systemMaintenanceFailure 10
Send a message to the manager that the system maintence operation fail. The variable in the variable binding indicates the problem.
TRAP-TYPE    

configChange 11
This notification indicates that the configuration data of one module is changed.
TRAP-TYPE    

moduleUp 12
A moduleUp trap signifies that the sending protocol entity recognizes that one of the modules represented in the agent's configuration has come up.
TRAP-TYPE    

moduleDown 13
A moduleDown trap signifies that the sending protocol entity recognizes a failure in one of the modules represented in the agent's configuration.
TRAP-TYPE    

modulePlugIn 14
A modulePlugIn trap signifies that the sending protocol entity recognizes that one module is plugged into the device.
TRAP-TYPE    

modulePullOut 15
A modulePullOut trap signifies that the sending protocol entity recognizes one module is pulled out from the device.
TRAP-TYPE    

powerDC48VAFailure 16
The trap signifies that the power supply of DC 48V at the right side of main Chassis (front view) failed.
TRAP-TYPE    

powerDC48VANormal 17
The trap signifies that the power supply of DC 48V at the right side of main Chassis (front view) is in normal state.
TRAP-TYPE    

powerDC48VBFailure 18
The trap signifies that the power supply of DC 48V at the left side of main Chassis (front view) failed.
TRAP-TYPE    

powerDC48VBNormal 19
The trap signifies that the power supply of DC 48V at the left side of main Chassis (front view) is in normal state.
TRAP-TYPE    

extAlarmInputTrigger 20
The trap signifies that the external alarm input of MSC card is triggered.
TRAP-TYPE    

extAlarmInputRelease 21
The trap signifies that the external alarm input of MSC card is released.
TRAP-TYPE    

thermalSensorFailure 22
The trap signifies that the thermal sensor failed.
TRAP-TYPE    

mscSwitchOverOK 23
The trap signifies that MSC card is switched over successfully. The value of iesSlotId is the slot ID of the current working MSC.
TRAP-TYPE    

networkTopologyChange 24
The trap signifies the network topology is changed.
TRAP-TYPE    

adslAtucLof 25
The trap signifies ATU-C Loss of Framing.
TRAP-TYPE    

adslAturLof 26
The trap signifies ATU-R Loss of Framing.
TRAP-TYPE    

adslAtucLos 27
The trap signifies ATU-C Loss of Signal.
TRAP-TYPE    

adslAturLos 28
The trap signifies ATU-R Loss of Signal.
TRAP-TYPE    

adslAturLpr 29
The trap signifies ATU-R Loss of Power.
TRAP-TYPE    

adslAtucLofClear 30
The trap signifies ATU-C Loss of Framing is cleared.
TRAP-TYPE    

adslAturLofClear 31
The trap signifies ATU-R Loss of Framing is cleared.
TRAP-TYPE    

adslAtucLosClear 32
The trap signifies ATU-C Loss of Signal is cleared.
TRAP-TYPE    

adslAturLosClear 33
The trap signifies ATU-R Loss of Signal is cleared.
TRAP-TYPE    

adslAturLprClear 34
The trap signifies ATU-R Loss of Power is cleared.
TRAP-TYPE