Zhone-GPON-MIB

File: Zhone-GPON-MIB.mib (185494 bytes)

Imported modules

IF-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC Zhone Zhone-TC

Imported symbols

InterfaceIndex OBJECT-GROUP NOTIFICATION-GROUP
Integer32 Unsigned32 Counter64
OBJECT-TYPE MODULE-IDENTITY OBJECT-IDENTITY
NOTIFICATION-TYPE TruthValue TEXTUAL-CONVENTION
zhoneRegPls zhoneRegCpe zhoneRegMux
zhoneRegSechtor zhoneRegWtn zhoneRegMalc
zhonePls zhoneZedge zhoneZplex
sechtor100 sechtor300 zhoneWtn
zhoneMalc zhoneZmsProduct zhoneSystem
zhoneShelf zhoneCard zhoneSubscriber
zhoneInterfaceTranslation zhoneInterfaceGroup zhoneMasterAgent
zhoneTrapModules zhoneGenWtn zhoneZAP
zhoneVoiceStats zhoneIp zhoneAtm
zhoneVoice zhoneVoip zhonePpp
zhoneIma zhoneBridge zhoneVideo
zhoneIsdn zhoneCes zhoneSs7
zhoneClass5 zhoneBonding zhoneEnet
zhoneDsx zhoneOcx zhoneDsl
zhoneConsole zhoneRadio zhoneSonet
zhoneDs3Ext zhoneLineTypes zhoneApon
zhoneVdsl zhoneGpon zhoneSlotIndex
zhoneModules zhoneShelfIndex zhoneGroups
zhoneShelfSlotGroup zhoneShelfSlotCompliance apsMIB
sipTC sipCommonMIB sipUAMIB
pktcIetfSigMib efmOamMIB efmCuMIB
zhoneDrafts ZhoneAdminString ZhoneRowStatus
ZhoneEnabledFlag

Defined Types

OnuUpgradeState  
Onu upgrade state, for queries and reporting.
TEXTUAL-CONVENTION    
  INTEGER none(0), queued(1), noUpgrade(2), downloading(3), complete(4), error(5), aborted(6), fileError(7), downloaded(8)  

GponCacRc  
This object contains the result code of the last GPON CAC request for the OLT. ok - GPON CAC requrest approved noReq - GPON CAC request has not been performed badParms - Internal error. Bad pointer or index value parameter to a GPON CAC procedure call cfgLookup - Internal error. Failed to look up a config record ( OLT, ONU, traffic profile, etc ) genError - Internal error. Invalid value was found inside a profile so a switch statement failed maxOnuGemPorts - Each ONU supports a limited number of GEM ports maxOltAllocIds - Each OLT supports a limited number of allocIds maxOltDbaAllocIds - Each OLT supports a limited number of DBA-enabled allocIds maxBw - An attempt was made to create a new GEM port or modifying an existing GEM port but the there is no available total bandwidth maxCbrBw - An attempt was made to create a new GEM port or modifying an existing GEM port but the there is no available CBR bandwidth trafficClassChg - An attempt was made to change a GEM port traffic profile index. The change was not allowed because the new traffic profile has a different traffic class dbaStatusChg - An attempt was made to change a GEM port traffic profile index. The change was not allowed because the new traffic profile has a different DBA Enabled status testCreateInvalidParms - GEM Port cannot be created because there are invalid paramater values used to create the GEM Port. testCreateMissingParms - GEM Port cannot be created because there are missing paramater values used to create the GEM Port. testCreateAlreadyExistsIfIndex - GEM Port cannot be created because a GEM Port already exists with the specified ifIndex testCreateAlreadyExistsSSPS - GEM Port cannot be created because a GEM Port already exists with the specified shelf, slot, port and subPort values. testCreateOnuDoesNotExist - GEM Port cannot be created because the specified GEM Port ONU does not exist testCreateOnuNotRegistered - GEM Port cannot be created because the GEM Port ONU has not been registered with the LINERR testCreateCannotFindPrimary - GEM Port cannot be created because the GEM Port Primary OLT cannot be located testCreateCannotAddToSecondary - GEM Port cannot be created on the secondary OLT of an OLT line redundancy group
TEXTUAL-CONVENTION    
  INTEGER ok(1), noReq(2), badParms(3), cfgLookup(4), genError(5), maxOnuGemPorts(6), maxOltAllocIds(7), maxOltDbaAllocIds(8), maxBw(9), maxCbrBw(10), trafficClassChg(11), dbaStatusChg(12), testCreateInvalidParms(13), testCreateMissingParms(14), testCreateAlreadyExistsIfIndex(15), testCreateAlreadyExistsSSPS(16), testCreateOnuDoesNotExist(17), testCreateOnuNotRegistered(18), testCreateCannotFindPrimary(19), testCreateCannotAddToSecondary(20)  

ZhoneGponOltConfigEntry  
SEQUENCE    
  zhoneGponOltIfIndex InterfaceIndex
  zhoneGponOltConfigMaxRtPropagationDelay Integer32
  zhoneGponOltConfigMaxOnuResponseTime Integer32
  zhoneGponOltConfigPreassignedEqD Integer32
  zhoneGponOltConfigLosAlpha Integer32
  zhoneGponOltConfigLofAlpha Integer32
  zhoneGponOltConfigLoamAlpha Integer32
  zhoneGponOltConfigScrambler ZhoneEnabledFlag
  zhoneGponOltConfigFecMode ZhoneEnabledFlag
  zhoneGponOltConfigAutoLearn ZhoneEnabledFlag
  zhoneGponOltConfigPowerLevel Unsigned32
  zhoneGponOltConfigGuardBitCount Integer32
  zhoneGponOltConfigDbaMode INTEGER
  zhoneGponOltConfigGemBlockSize Integer32
  zhoneGponOltConfigUsBerInterval Integer32
  zhoneGponOltConfigDsBerInterval Integer32
  zhoneGponOltConfigBerSfThreshold Integer32
  zhoneGponOltConfigBerSdThreshold Integer32
  zhoneGponOltConfigFecRequest ZhoneEnabledFlag
  zhoneGponOltConfigKeyExchange ZhoneEnabledFlag
  zhoneGponOltConfigMinRtPropagationDelay Integer32
  zhoneGponOltConfigMinOnuResponseTime Integer32
  zhoneGponOltConfigEqDMeasureCycles Integer32
  zhoneGponOltConfigDriftControlInterval Integer32
  zhoneGponOltConfigDriftControlLimit Integer32
  zhoneGponOltConfigAllocCycleLength Integer32
  zhoneGponOltConfigMinUsAlloc Integer32
  zhoneGponOltConfigAckTimeout Integer32
  zhoneGponOltConfigPlsMaxAllocSize Integer32
  zhoneGponOltConfigDbaCycle Unsigned32
  zhoneGponOltConfigSrDbaReportingBlockSize Unsigned32
  zhoneGponOltConfigProtectionSwitchoverTimer Unsigned32
  zhoneGponOltConfigPreambleOverride ZhoneEnabledFlag
  zhoneGponOltConfigPreambleType0 OCTET STRING
  zhoneGponOltConfigPreambleType1 OCTET STRING
  zhoneGponOltConfigPreambleType3PreRange OCTET STRING
  zhoneGponOltConfigPreambleType3PostRange OCTET STRING
  zhoneGponOltConfigPreambleType3Pattern OCTET STRING
  zhoneGponOltConfigBipErrorMonitoring INTEGER
  zhoneGponOltConfigBipErrorsPerSampleThreshold Integer32
  zhoneGponOltConfigBipErroredSamplesThreshold Integer32
  zhoneGponOltConfigBipMaxSampleGap Integer32
  zhoneGponOltConfigRogueOnuDetection INTEGER
  zhoneGponOltConfigRogueOnuDetectFrequency Integer32
  zhoneGponOltConfigRogueOnuRxPowerThreshold Integer32

ZhoneGponOltOnuConfigEntry  
SEQUENCE    
  zhoneGponOltOnuIfIndex InterfaceIndex
  zhoneGponOltOnuConfigSerialNoVendorId ZhoneAdminString
  zhoneGponOltOnuConfigSerialNoVendorSpecific ZhoneAdminString
  zhoneGponOltOnuConfigPassword ZhoneAdminString
  zhoneGponOltOnuConfigAutoLearn ZhoneEnabledFlag
  zhoneGponOltOnuConfigPowerLevel Integer32
  zhoneGponOltOnuConfigUsBerInterval Integer32
  zhoneGponOltOnuConfigDsBerInterval Integer32
  zhoneGponOltOnuConfigOnuAdded TruthValue
  zhoneGponOltOnuConfigOmciFileName ZhoneAdminString
  zhoneGponOltOnuConfigMEProfileName ZhoneAdminString
  zhoneGponOltOnuConfigGenericProfileName ZhoneAdminString
  zhoneGponOltOnuConfigPhysicalTraps ZhoneEnabledFlag
  zhoneGponOltOnuConfigOntTraps ZhoneEnabledFlag
  zhoneGponOltOnuConfigLineStatusTraps INTEGER
  zhoneGponOltOnuConfigAutoUpgrade ZhoneEnabledFlag
  zhoneGponOltOnuConfigSerialNoVendorSpecificFsan OCTET STRING
  zhoneGponOltOnuConfigUseRegId ZhoneEnabledFlag
  zhoneGponOltOnuConfigModel OCTET STRING
  zhoneGponOltOnuConfigOntVersion OCTET STRING
  zhoneGponOltOnuConfigImageVersionActive OCTET STRING
  zhoneGponOltOnuConfigImageVersionStandby OCTET STRING
  zhoneGponOltOnuConfigUsRxPowerMonitoring INTEGER
  zhoneGponOltOnuConfigUsRxPowerHighThreshold Integer32
  zhoneGponOltOnuConfigUsRxPowerLowThreshold Integer32
  zhoneGponOltOnuConfigDbaStatusReporting ZhoneEnabledFlag
  zhoneGponOltOnuConfigOmciDataSync Unsigned32
  zhoneGponOltOnuConfigSnmpDataSync Unsigned32
  zhoneGponOltOnuConfigNextAvailableGemPort Integer32
  zhoneGponOltOnuConfigAutoConfigState INTEGER
  zhoneGponOltOnuConfigLinkStatusAlarmSeverity INTEGER

ZhoneGponPortConfigEntry  
SEQUENCE    
  zhoneGponPortIfIndex InterfaceIndex
  zhoneGponPortConfigRowStatus ZhoneRowStatus
  zhoneGponPortConfigMulticast TruthValue
  zhoneGponPortConfigEncrypted TruthValue
  zhoneGponPortConfigDirection INTEGER
  zhoneGponPortConfigTrafficProfile Unsigned32
  zhoneGponPortConfigRowShelf Unsigned32
  zhoneGponPortConfigRowSlot Unsigned32
  zhoneGponPortConfigRowOlt Unsigned32
  zhoneGponPortConfigRowPort Unsigned32
  zhoneGponPortConfigRowTrafficProfile Unsigned32
  zhoneGponPortConfigRowOnuId Unsigned32
  zhoneGponPortConfigTrafficManagementProfileIndex Unsigned32

ZhoneGponAllocIdEntry  
SEQUENCE    
  zhoneGponAllocIdIndex Integer32
  zhoneGponAllocIdRowStatus ZhoneRowStatus
  zhoneGponAllocIdOnuId Integer32
  zhoneGponAllocIdGuaranteedBw Integer32
  zhoneGponAllocIdTrafficClass INTEGER
  zhoneGponAllocIdCompensated TruthValue

ZhoneGponSerialNoEntry  
SEQUENCE    
  zhoneGponSerialNoOltLgIfIndex InterfaceIndex
  zhoneGponSerialNoIndexId Unsigned32
  zhoneGponSerialNoVendorId ZhoneAdminString
  zhoneGponSerialNoVendorSpecific ZhoneAdminString
  zhoneGponSerialNoTimeStamp OCTET STRING

ZhoneGponOnuStatusEntry  
SEQUENCE    
  zhoneGponOnuStatusWord BITS
  zhoneGponOnuOmciState INTEGER
  zhoneGponOnuOpticRssi Integer32
  zhoneGponOntRxPower Integer32
  zhoneGponOntVersion OCTET STRING
  zhoneGponOnuDistance Unsigned32

ZhoneOnuOmciMEProfileEntry  
SEQUENCE    
  zhoneOnuOmciMEProfileIndex Unsigned32
  zhoneOnuOmciMEProfileRowStatus INTEGER
  zhoneOnuOmciMEProfileName OCTET STRING
  zhoneOnuOmciMEProfileOmciCommands OCTET STRING
  zhoneOnuOmciMEProfileFileName OCTET STRING

ZhoneOnuOmciGenericProfileEntry  
SEQUENCE    
  zhoneOnuOmciGenericProfileIndex Unsigned32
  zhoneOnuOmciGenericProfileRowStatus INTEGER
  zhoneOnuOmciGenericProfileName OCTET STRING
  zhoneOnuOmciGenericProfileOmciCommands OCTET STRING
  zhoneOnuOmciGenericProfileMESrcProfileName OCTET STRING
  zhoneOnuOmciGenericProfileFileName OCTET STRING

ZhoneOnuOmciSpecificProfileEntry  
SEQUENCE    
  zhoneOnuOmciSpecificProfileIndex InterfaceIndex
  zhoneOnuOmciSpecificProfileRowStatus INTEGER
  zhoneOnuOmciSpecificProfileOmciCommands OCTET STRING
  zhoneOnuOmciSpecificProfileMESrcProfileName OCTET STRING
  zhoneOnuOmciSpecificProfileFileName OCTET STRING

ZhoneGponOmciOnuAlarmsEntry  
SEQUENCE    
  zhoneGponOmciOnuAlarmsText OCTET STRING

ZhoneGponTrafficProfileEntry  
SEQUENCE    
  zhoneGponTrafficProfileIndex Unsigned32
  zhoneGponTrafficProfileRowStatus ZhoneRowStatus
  zhoneGponTrafficProfileGuaranteedUpstreamBw Integer32
  zhoneGponTrafficProfileClass INTEGER
  zhoneGponTrafficProfileCompensated TruthValue
  zhoneGponTrafficProfileShared TruthValue
  zhoneGponTrafficProfileDbaEnabled TruthValue
  zhoneGponTrafficProfileDbaFixedUsUbrBw Unsigned32
  zhoneGponTrafficProfileDbaFixedUsCbrBw Unsigned32
  zhoneGponTrafficProfileDbaAssuredUsBw Unsigned32
  zhoneGponTrafficProfileMaxUsBw Unsigned32
  zhoneGponTrafficProfileExtraUsBwType INTEGER

ZhoneGponPortStatusEntry  
SEQUENCE    
  zhoneGponPortStatusAllocId Unsigned32
  zhoneGponPortStatusDbaStatus INTEGER

ZhoneGponOmciStatsCurrentEntry  
SEQUENCE    
  zhoneGponOmciStatsCurrentMEId Unsigned32
  zhoneGponOmciStatsCurrentLogicalPort Unsigned32
  zhoneGponOmciStatsCurrentText OCTET STRING

ZhoneGponOmciStatsPreviousEntry  
SEQUENCE    
  zhoneGponOmciStatsPreviousMEId Unsigned32
  zhoneGponOmciStatsPreviousLogicalPort Unsigned32
  zhoneGponOmciStatsPreviousText OCTET STRING

ZhoneGponOmciStatusEntry  
SEQUENCE    
  zhoneGponOmciStatusMEId Unsigned32
  zhoneGponOmciStatusLogicalPort Unsigned32
  zhoneGponOmciStatusText OCTET STRING

ZhoneGponOmciOnuRebootEntry  
SEQUENCE    
  zhoneGponOmciOnuReboot INTEGER

ZhoneGponOmciOnuPortAdminEntry  
SEQUENCE    
  zhoneGponOmciOnuPortAdminMEId Unsigned32
  zhoneGponOmciOnuPortAdminLogicalPort Unsigned32
  zhoneGponOmciOnuPortAdminState INTEGER
  zhoneGponOmciOnuPortAdminAutoDetect INTEGER

ZhoneGponOmciOnuImageUpgradeEntry  
SEQUENCE    
  zhoneGponOmciOnuImageUpgradeAction INTEGER
  zhoneOnuOmciImageUpgradeFilename OCTET STRING
  zhoneGponOmciOnuImageUpgradePartition INTEGER
  zhoneOnuOmciImageUpgradeImageVersionPartition0 OCTET STRING
  zhoneOnuOmciImageUpgradeImageVersionPartition1 OCTET STRING
  zhoneOnuOmciImageUpgradeIsCommittedPartition0 INTEGER
  zhoneOnuOmciImageUpgradeIsCommittedPartition1 INTEGER
  zhoneOnuOmciImageUpgradeIsActivatedPartition0 INTEGER
  zhoneOnuOmciImageUpgradeIsActivatedPartition1 INTEGER
  zhoneOnuOmciImageUpgradeIsValidPartition0 INTEGER
  zhoneOnuOmciImageUpgradeIsValidPartition1 INTEGER
  zhoneOnuOmciImageUpgradeDownloadStatus OnuUpgradeState
  zhoneGponOmciOnuImageUpgradeModel OCTET STRING
  zhoneGponOmciOnuImageUpgradeStartTime OCTET STRING
  zhoneGponOmciOnuImageUpgradeWillBeActivated TruthValue
  zhoneGponOmciOnuImageUpgradeWillBeCommitted TruthValue
  zhoneGponOmciOnuImageUpgradeType INTEGER
  zhoneGponOmciOnuImageDownloadProgressPercentage INTEGER
  zhoneGponOmciOnuImageUpgradeMethod INTEGER

ZhoneGponOltStatusEntry  
SEQUENCE    
  zhoneGponOltOpticTemperature Integer32
  zhoneGponOltOpticVoltage Unsigned32
  zhoneGponOltOpticTxBiasCurrent Unsigned32
  zhoneGponOltOpticTxPower Integer32
  zhoneGponOltOpticStatus INTEGER
  zhoneGponOltOpticAlarms BITS
  zhoneGponOltStatusWord BITS
  zhoneGponOltConfiguredOnuCount Unsigned32
  zhoneGponOltActiveOnuCount Unsigned32

ZhoneGponOltDbaStatusEntry  
SEQUENCE    
  zhoneGponOltDbaTotalAvailableBw Unsigned32
  zhoneGponOltDbaTotalAvailableCompensatedCbrBw Unsigned32
  zhoneGponOltDbaAllocatedUbrBw Unsigned32
  zhoneGponOltDbaAllocatedCbrBw Unsigned32
  zhoneGponOltDbaAllocatedCompensatedCbrBw Unsigned32
  zhoneGponOltDbaAllocatedAssuredBw Unsigned32
  zhoneGponOltDbaAllocatedNonAssuredBw Unsigned32
  zhoneGponOltDbaAllocatedBestEffortBw Unsigned32
  zhoneGponOltDbaMaxAllocIds Unsigned32
  zhoneGponOltDbaAvailAllocIds Unsigned32
  zhoneGponOltDbaUsedAllocIds Unsigned32
  zhoneGponOltDbaMaxDbaAllocIds Unsigned32
  zhoneGponOltDbaAvailDbaAllocIds Unsigned32
  zhoneGponOltDbaUsedDbaAllocIds Unsigned32
  zhoneGponOltDbaTotalOltGemPorts Unsigned32
  zhoneGponOltDbaLastCacRc GponCacRc

ZhoneGponUpgradeByStateEntry  
SEQUENCE    
  zhoneGponUpgradeOlt Integer32
  zhoneGponUpgradeOnu Integer32
  zhoneGponUpgradeModel OCTET STRING
  zhoneGponUpgradeStartTime OCTET STRING
  zhoneGponUpgradeIfIndex InterfaceIndex
  zhoneGponUpgradeByStateOnuState OnuUpgradeState
  zhoneGponUpgradeByStateWillBeActivated TruthValue
  zhoneGponUpgradeByStateWillBeCommitted TruthValue
  zhoneGponUpgradeByStateUpgradeType INTEGER
  zhoneGponUpgradeByStatePartition INTEGER
  zhoneGponUpgradeProgressPercentage INTEGER
  zhoneGponUpgradeByStateMethod INTEGER

ZhoneGponOltStatisticsEntry  
SEQUENCE    
  zhoneGponOltStatisticsUpstreamValidGemFrames Counter64
  zhoneGponOltStatisticsUpstreamDiscardedFrames Counter64
  zhoneGponOltStatisticsUpstreamGemFrames Counter64
  zhoneGponOltStatisticsUpstreamOmciFrames Counter64
  zhoneGponOltStatisticsUpstreamPloamFrames Counter64
  zhoneGponOltStatisticsUpstreamIdlePloamFrames Counter64
  zhoneGponOltStatisticsDownstreamValidGemFrames Counter64
  zhoneGponOltStatisticsDownstreamDiscardedFrames Counter64
  zhoneGponOltStatisticsDownstreamGemFrames Counter64
  zhoneGponOltStatisticsDownstreamOmciFrames Counter64
  zhoneGponOltStatisticsDownstreamPloamFrames Counter64
  zhoneGponOltStatisticsDownstreamIdlePloamFrames Counter64
  zhoneGponOltStatisticsDownstreamPonValidEthernetPkts Counter64
  zhoneGponOltStatisticsDownstreamPonCpuPkts Counter64
  zhoneGponOltStatisticsDownstreamTxBytes Counter64
  zhoneGponOltStatisticsUpstreamPonValidPkts Counter64
  zhoneGponOltStatisticsUpstreamPonValidNotIdlePloams Counter64
  zhoneGponOltStatisticsUpstreamPonErrorPloams Counter64
  zhoneGponOltStatisticsUpstreamPonInvalidPkts Counter64
  zhoneGponOltStatisticsUpstreamDroppedPktsInactivePorts Counter64
  zhoneGponOltStatisticsUpstreamDroppedPloamsFifoFull Counter64
  zhoneGponOltStatisticsDownstreamTmValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmCrcPkts Counter64
  zhoneGponOltStatisticsDownstreamTmDroppedCpuPkts Counter64
  zhoneGponOltStatisticsDownstreamTmMacLookupMiss Counter64
  zhoneGponOltStatisticsDownstreamTmPktsForwardedFromHmToPon Counter64
  zhoneGponOltStatisticsDownstreamTmPktsDroppedGemPidNotEnabled Counter64
  zhoneGponOltStatisticsDownstreamTmQ0ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ0DroppedPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ1ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ1DroppedPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ2ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ2DroppedPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ3ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ3DroppedPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ4ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ4DroppedPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ5ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ5DroppedPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ6ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ6DroppedPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ7ValidPkts Counter64
  zhoneGponOltStatisticsDownstreamTmQ7DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmDroppedCpuPkts Counter64
  zhoneGponOltStatisticsUpstreamTmDroppedPktsCrcError Counter64
  zhoneGponOltStatisticsUpstreamTmDroppedPktsSecurity Counter64
  zhoneGponOltStatisticsUpstreamTmLearnFailures Counter64
  zhoneGponOltStatisticsUpstreamTmQ0ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ0DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ1ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ1DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ2ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ2DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ3ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ3DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ4ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ4DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ5ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ5DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ6ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ6DroppedPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ7ValidPkts Counter64
  zhoneGponOltStatisticsUpstreamTmQ7DroppedPkts Counter64
  zhoneGponOltStatisticsClearStats TruthValue

ZhoneGponUpstreamOntStatisticsEntry  
SEQUENCE    
  zhoneGponUpstreamOntStatisticsUpstreamBipErrors Counter64
  zhoneGponUpstreamOntStatisticsFecCorrectedBytes Counter64
  zhoneGponUpstreamOntStatisticsFecCorrectedCodewords Counter64
  zhoneGponUpstreamOntStatisticsFecUncorrectedCodewords Counter64
  zhoneGponUpstreamOntStatisticsTotalRxCodewords Counter64
  zhoneGponUpstreamOntStatisticsUnreceivedBursts Counter64
  zhoneGponUpstreamOntStatisticsBipErrors Counter64
  zhoneGponUpstreamOntStatisticsRemoteBipErrors Counter64
  zhoneGponUpstreamOntStatisticsDriftOfWindowIndications Counter64
  zhoneGponUpstreamOntStatisticsMessageErrorMessage Counter64
  zhoneGponUpstreamOntStatisticsClearStats TruthValue

Defined Values

zhoneGponOltMIB 1.3.6.1.4.1.5504.6.111
This is the Zhone GPON mib which contains SNMP objects for GPON ONU configuration, alarms, and status.It also includes the GPON OLT status information.
MODULE-IDENTITY    

zhoneGponObjectID 1.3.6.1.4.1.5504.5.14.1
OBJECT IDENTIFIER    

zhoneGponOltConfigTable 1.3.6.1.4.1.5504.5.14.1.1
Configuration parameters that apply to one OLT. This profile is auto-created.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOltConfigEntry

zhoneGponOltConfigEntry 1.3.6.1.4.1.5504.5.14.1.1.1
One row of the gpon olt config entry table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOltConfigEntry  

zhoneGponOltIfIndex 1.3.6.1.4.1.5504.5.14.1.1.1.1
The ifIndex of the physical olt interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

zhoneGponOltConfigMaxRtPropagationDelay 1.3.6.1.4.1.5504.5.14.1.1.1.2
Maximum round trip propagation delay. Combined with max ONU response time and preassigned delay determins maximum logical PON distance. Default 200 usec for 20 dm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigMaxOnuResponseTime 1.3.6.1.4.1.5504.5.14.1.1.1.3
Combined with max rt propagation delay, determins maximum logical PON distance.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigPreassignedEqD 1.3.6.1.4.1.5504.5.14.1.1.1.4
Combined with max rt propagation delay and max onu response time determines max logical PON distance.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigLosAlpha 1.3.6.1.4.1.5504.5.14.1.1.1.5
Number of loss-of-signal occurrences to trigger alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigLofAlpha 1.3.6.1.4.1.5504.5.14.1.1.1.6
Number of loss-of-frame occurrences to trigger alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigLoamAlpha 1.3.6.1.4.1.5504.5.14.1.1.1.7
Number of loss-of-OAM occurrences to trigger alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigScrambler 1.3.6.1.4.1.5504.5.14.1.1.1.8
Description.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltConfigFecMode 1.3.6.1.4.1.5504.5.14.1.1.1.9
Enables or disables forward error correction.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltConfigAutoLearn 1.3.6.1.4.1.5504.5.14.1.1.1.10
Enable or disable password auto-learn mode.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltConfigPowerLevel 1.3.6.1.4.1.5504.5.14.1.1.1.11
Olt power level. For the Broadlight 3000, values will be rounded down to one of 0, 3, or 6.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltConfigGuardBitCount 1.3.6.1.4.1.5504.5.14.1.1.1.12
Number of guard bits for upstream transmission.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigDbaMode 1.3.6.1.4.1.5504.5.14.1.1.1.13
Working DBA mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER predictive(1), piggyback(2), wholeReport(3)  

zhoneGponOltConfigGemBlockSize 1.3.6.1.4.1.5504.5.14.1.1.1.14
Basic unit in bytes used by all ONUs for DBA reports of their queue occupancy (for piggyback and whole-report DBA only).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigUsBerInterval 1.3.6.1.4.1.5504.5.14.1.1.1.15
Interval for upstream bit error rate calculation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigDsBerInterval 1.3.6.1.4.1.5504.5.14.1.1.1.16
Interval used for downstream bit error rate calculation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigBerSfThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.17
Threshold is 10**(-N) for signal fail.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..8  

zhoneGponOltConfigBerSdThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.18
Threshold is 10**(-N) for signal degrade. Must exceed sf threshold.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 4..9  

zhoneGponOltConfigFecRequest 1.3.6.1.4.1.5504.5.14.1.1.1.19
Indicates whether OLT turns on FEC indication for all Alloc-Id in the Upstream Bandwidth Map.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltConfigKeyExchange 1.3.6.1.4.1.5504.5.14.1.1.1.20
Specifies whether Single Key exchange should be performed during ONU activation process.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltConfigMinRtPropagationDelay 1.3.6.1.4.1.5504.5.14.1.1.1.21
If closest ONU location is known, GPON_stack uses this value in order to limit the size of the quiet zone.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigMinOnuResponseTime 1.3.6.1.4.1.5504.5.14.1.1.1.22
GPON_stack uses this value in order to limit the size of the quiet zone.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigEqDMeasureCycles 1.3.6.1.4.1.5504.5.14.1.1.1.23
Defines the number of measurement cycles in the Ranging process.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigDriftControlInterval 1.3.6.1.4.1.5504.5.14.1.1.1.24
Defines the interval of periodic monitoring on drifts of upstream data.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigDriftControlLimit 1.3.6.1.4.1.5504.5.14.1.1.1.25
Indicates the limit of upstream data drift.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigAllocCycleLength 1.3.6.1.4.1.5504.5.14.1.1.1.26
Alloc-ID assignment map cycle length.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

zhoneGponOltConfigMinUsAlloc 1.3.6.1.4.1.5504.5.14.1.1.1.27
Size of minimal upstream allocation per frame.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigAckTimeout 1.3.6.1.4.1.5504.5.14.1.1.1.28
Timeout length of Acknowledge message.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigPlsMaxAllocSize 1.3.6.1.4.1.5504.5.14.1.1.1.29
Indecates a size of unassigned allocation that should be attached to the end of ranging window.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigDbaCycle 1.3.6.1.4.1.5504.5.14.1.1.1.30
The Dynamic Bandwidth Allocation(dba) cycle determines the DBA interval size. Its an integer multiplicant of 2 milli seconds. The range of values for the dba cycle can be between 2ms-10ms.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 2..10  

zhoneGponOltConfigSrDbaReportingBlockSize 1.3.6.1.4.1.5504.5.14.1.1.1.31
For DBA of SR type, the block size defines the resolution of the status reports per PON link.The default value is 48 bytes.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltConfigProtectionSwitchoverTimer 1.3.6.1.4.1.5504.5.14.1.1.1.32
If we receive LOS alarm for a link in Active state, the link state changes to Switch Over Pending state. If the actual switch-over does not happen after this protection-switchover-timeout expires, the link will go back to Active state
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltConfigPreambleOverride 1.3.6.1.4.1.5504.5.14.1.1.1.33
Used to force the OLT to use the Preamble configuration in the OLT configuration profile. Otherwise the Preamble configuration will be determined at runtime and based on the SFP.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltConfigPreambleType0 1.3.6.1.4.1.5504.5.14.1.1.1.34
Byte number for preamble type 0. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

zhoneGponOltConfigPreambleType1 1.3.6.1.4.1.5504.5.14.1.1.1.35
Byte number for preamble type 1. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

zhoneGponOltConfigPreambleType3PreRange 1.3.6.1.4.1.5504.5.14.1.1.1.36
Byte number for preamble type 3 pre-ranging. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

zhoneGponOltConfigPreambleType3PostRange 1.3.6.1.4.1.5504.5.14.1.1.1.37
Byte number for preamble type 3 post-ranging. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

zhoneGponOltConfigPreambleType3Pattern 1.3.6.1.4.1.5504.5.14.1.1.1.38
Preamble type 3 pattern. This string represents a hex value with range 0x00 to 0xFF. String must have the following format: 0xNN where where N is 0..9, A..F, a..f
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

zhoneGponOltConfigBipErrorMonitoring 1.3.6.1.4.1.5504.5.14.1.1.1.39
If in disabled mode, do not report BIP errors, do not disable ONU and do not throw any traps. If in monitorOnly mode, monitor BIP errors and if BIP Error Threshold exceeded, set appropriate zhoneGponOnuStatusWord bits based on the type of BIP errors and throw zhoneGponOnuError trap. If in blockOnError mode, monitor BIP errors and if BIP Error Threshold exceeded, block traffic, disable ONU ranging, set appropriate zhoneGponOnuStatusWord bits based on the type of BIP errors, and throw zhoneGponOnuError and linkDownTrap traps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), monitorOnly(2), blockOnError(3)  

zhoneGponOltConfigBipErrorsPerSampleThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.40
If the number of BIP errors per sample exceeds this threshold, it is counted as an errored sample.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigBipErroredSamplesThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.41
If the number of errored samples exceed this sample threshold, report and disable the onu if in blockOnError mode, otherwise simply report the threshold as being exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigBipMaxSampleGap 1.3.6.1.4.1.5504.5.14.1.1.1.42
If two adjancent errored samples were taken farther apart than this threshold, do not count the earlier sample as an errored sample.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltConfigRogueOnuDetection 1.3.6.1.4.1.5504.5.14.1.1.1.43
Controls detection of rogue ONU on fiber. Values are: 1. detection disabled 2. detect via measurement from rssi process 3. detect via indication from background process. 4. normally off, but switch to rssi mode if rogue is suspected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), rogueRssi(2), backgroundProcess(3), autoRssi(4)  

zhoneGponOltConfigRogueOnuDetectFrequency 1.3.6.1.4.1.5504.5.14.1.1.1.44
Frequency in seconds for detection background task.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

zhoneGponOltConfigRogueOnuRxPowerThreshold 1.3.6.1.4.1.5504.5.14.1.1.1.45
Power level below which to report rssi rogue ONU.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltOnuConfigTable 1.3.6.1.4.1.5504.5.14.1.2
Configuration parameters applying to a single onu stacked on an olt. This profile is auto-created.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOltOnuConfigEntry

zhoneGponOltOnuConfigEntry 1.3.6.1.4.1.5504.5.14.1.2.1
A row in the gpon olt-onu config table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOltOnuConfigEntry  

zhoneGponOltOnuIfIndex 1.3.6.1.4.1.5504.5.14.1.2.1.1
IfIndex of the onu interface stacked on the olt.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

zhoneGponOltOnuConfigSerialNoVendorId 1.3.6.1.4.1.5504.5.14.1.2.1.2
This is a string of 4 ascii characters representing the vendor ID portion of the onu serial number. Example: 'ZNTS' for Zhone.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneAdminString Size(0..4)  

zhoneGponOltOnuConfigSerialNoVendorSpecific 1.3.6.1.4.1.5504.5.14.1.2.1.3
This is a string of ascii decimal digits representing the vendor-specific portion of the onu serial number.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneAdminString Size(1..10)  

zhoneGponOltOnuConfigPassword 1.3.6.1.4.1.5504.5.14.1.2.1.4
Password (10 bytes).
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneAdminString Size(0..10)  

zhoneGponOltOnuConfigAutoLearn 1.3.6.1.4.1.5504.5.14.1.2.1.5
Indicates whether password is auto-learned.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltOnuConfigPowerLevel 1.3.6.1.4.1.5504.5.14.1.2.1.6
Olt power level. For the Broadlight 3000, values will be rounded down to one of 0, 3, or 6.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltOnuConfigUsBerInterval 1.3.6.1.4.1.5504.5.14.1.2.1.7
Interval for upstream bit error rate calculation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltOnuConfigDsBerInterval 1.3.6.1.4.1.5504.5.14.1.2.1.8
Interval for downstream bit error rate.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltOnuConfigOnuAdded 1.3.6.1.4.1.5504.5.14.1.2.1.9
Indicates to Broadlight that onu is activated. May not be used.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

zhoneGponOltOnuConfigOmciFileName 1.3.6.1.4.1.5504.5.14.1.2.1.10
Name of OMCI configuration file for this ONT.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneAdminString  

zhoneGponOltOnuConfigMEProfileName 1.3.6.1.4.1.5504.5.14.1.2.1.11
This is the name of a Profile that contains OMCI commands which can configure an ONU. It is expected that this Profile contain OMCI commands that configure the Managed Entities (ME) on an ONU.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneAdminString  

zhoneGponOltOnuConfigGenericProfileName 1.3.6.1.4.1.5504.5.14.1.2.1.12
This is the name of a Profile that contains OMCI commands which can configure an ONU. It is expected that this Profile contain generic commands that are common to multiple ONUs.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneAdminString  

zhoneGponOltOnuConfigPhysicalTraps 1.3.6.1.4.1.5504.5.14.1.2.1.13
If enabled, then an asynchronous notification from the ONT with ME class ONT-G triggers an omciOnuAlarms trap. The alarm conditions for this ME class are: equipment alarm, powering alarm, battery missing, battery failure, battery low, physical intrusion alarm, and self-test failure.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltOnuConfigOntTraps 1.3.6.1.4.1.5504.5.14.1.2.1.14
If enabled, then an asynchronous notification from the ONT with ME class other than ONT-G triggers an omciOnuAlarms trap.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltOnuConfigLineStatusTraps 1.3.6.1.4.1.5504.5.14.1.2.1.15
If enabled, then gponOnuLineStatusChange traps, and also LinkUp/LinkDown traps, are sent whenever line status changes between up and down. If disabled, none of these traps is sent. If auto, then line status traps are sent if the 'dying gasp' flag is on (for line down), or if the 'dying gasp' flag was on (for line up). Link down/up traps are not sent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), auto(3), linkonly(4)  

zhoneGponOltOnuConfigAutoUpgrade 1.3.6.1.4.1.5504.5.14.1.2.1.16
If enabled, then the ONU s/w will be upgraded if the ONU version does not match the assoicated remote upgrade profile. Changing this variable to disabled will not abort a remote software upgrade already in progress.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltOnuConfigSerialNoVendorSpecificFsan 1.3.6.1.4.1.5504.5.14.1.2.1.17
This is a string of ascii decimal digits representing the vendor-specific portion of the onu serial number in hex format ( FSAN ).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..9)  

zhoneGponOltOnuConfigUseRegId 1.3.6.1.4.1.5504.5.14.1.2.1.18
If enabled, and if the onu is activated, then when an ONT is discovered with a registration ID that matches this ONU's password field, then the ONU will be auto-assigned to that ONT.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltOnuConfigModel 1.3.6.1.4.1.5504.5.14.1.2.1.19
Model ID returned from this Onu.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

zhoneGponOltOnuConfigOntVersion 1.3.6.1.4.1.5504.5.14.1.2.1.20
This object defines the version of the ONT as defined by the vendor. The character value '0' indicates that the version information is not available or applicable.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..14)  

zhoneGponOltOnuConfigImageVersionActive 1.3.6.1.4.1.5504.5.14.1.2.1.21
Version information for the active s/w image.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneGponOltOnuConfigImageVersionStandby 1.3.6.1.4.1.5504.5.14.1.2.1.22
Version information for the standby s/w image.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneGponOltOnuConfigUsRxPowerMonitoring 1.3.6.1.4.1.5504.5.14.1.2.1.23
If in disabled mode, do not report Upstream Onu Rx Power errors, do not disable ONU and do not throw any traps. If in monitorOnly mode, monitor Upstream Onu Rx Power levels and if level is outside of thresholds, set appropriate zhoneGponOnuStatusWord bits and throw zhoneGponOnuError trap. If in blockOnError mode, monitor Upstream Onu Rx Power levels and if level is outside of thresholds, block traffic, disable ONU ranging, set appropriate zhoneGponOnuStatusWord bits and throw both zhoneGponOnuError and linkDownTrap traps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), monitorOnly(2), blockOnError(3)  

zhoneGponOltOnuConfigUsRxPowerHighThreshold 1.3.6.1.4.1.5504.5.14.1.2.1.24
Upstream Receive Power High Threshold value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltOnuConfigUsRxPowerLowThreshold 1.3.6.1.4.1.5504.5.14.1.2.1.25
Upstream Receive Power Low Threshold value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zhoneGponOltOnuConfigDbaStatusReporting 1.3.6.1.4.1.5504.5.14.1.2.1.26
There are two types of DBA, Status Reporting and Non Status Reporting. The value is enabled or disabled. The default is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneEnabledFlag  

zhoneGponOltOnuConfigOmciDataSync 1.3.6.1.4.1.5504.5.14.1.2.1.27
If the MIB data sync value returned from the ONU on a MIB audit matches the MXK value, config not required.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltOnuConfigSnmpDataSync 1.3.6.1.4.1.5504.5.14.1.2.1.28
If the SNMP provisioning change value returned from the CPE matches the MXK value, config not required.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltOnuConfigNextAvailableGemPort 1.3.6.1.4.1.5504.5.14.1.2.1.29
Next available GEM PORT for the ONU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 257..3828  

zhoneGponOltOnuConfigAutoConfigState 1.3.6.1.4.1.5504.5.14.1.2.1.30
Track whether the ONU has been auto-configured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER init(1), done(2), disabled(3), error(4)  

zhoneGponOltOnuConfigLinkStatusAlarmSeverity 1.3.6.1.4.1.5504.5.14.1.2.1.31
Based on the severity set in this field LinkUp/LinkDown alarms are raised.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER critical(1), major(2), minor(3)  

zhoneGponPortConfigTable 1.3.6.1.4.1.5504.5.14.1.3
The gpon port is similiar to VCLs in ATM. Data is transferred between OLT and ONU via ports. This profile is dynamically created during CLI bridge-add, host-add, interface-add commands but must be explicitly created during SNMP operation. GEM ports can be created using a supplied I/F index value or using the next available I/F index value. Since the GEM Port is a virtual device, ZMS prefers to supply the I/F index value because ZMS cannot lookup the newly created GEM port using shelf/slot/olt/port indexing ( virual devices do not support these values). How to create a GEM port using next available I/F Index value, using a single SNMP packet with multiple var-binds: 1. Do an SNMP-Next of the object ifIndexNext to determine the I/F index value of the new GEM port. The SNMP-Next will not result in the auto-increment of ifIndexNext. 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.1 = create zhoneGponPortConfigRowShelf.1 = 1 zhoneGponPortConfigRowSlot.1 = GEM port slot zhoneGponPortConfigRowOlt.1 = GEM port OLT zhoneGponPortConfigRowPort.1 = GEM Port ID value zhoneGponPortConfigRowTrafficProfile.1 = traffic profile The GEM port will be created using the next available ifIndex. How to create a GEM port with a specified I/F index value, using a single SNMP packet with multiple var-binds: 1. Do an SNMP-Get of the object ifIndexNext to determine the next available I/F index value. The SNMP-Get will result in the auto-increment of ifIndexNext. 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.aaa = create zhoneGponPortConfigRowShelf.aaa = 1 zhoneGponPortConfigRowSlot.aaa = GEM port slot zhoneGponPortConfigRowOlt.aaa = GEM port OLT zhoneGponPortConfigRowPort.aaa = GEM Port ID value zhoneGponPortConfigRowTrafficProfile.aaa = traffic profile where aaa is the I/F index value collected in step 1. A GEM Port cannot be created if an I/F translate record already exists using the supplied I/F index value. How to delete a GEM port using a single SNMP packet: 1. Determine I/F index of GEM port config profile (aaa) 2. Issue single SNMP set command containing the following: zhoneGponPortConfigRowStatus.aaa = destroy Special Notes: 1. The deletion of a GEM port will be prevented if the GEM port supports bridges, interfaces, etc. 2. The GEM port ID value determines the GEM port ONU.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponPortConfigEntry

zhoneGponPortConfigEntry 1.3.6.1.4.1.5504.5.14.1.3.1
A row in the gpon port config table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponPortConfigEntry  

zhoneGponPortIfIndex 1.3.6.1.4.1.5504.5.14.1.3.1.1
The ifIndex of the gpon-port interface stacked on the olt.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

zhoneGponPortConfigRowStatus 1.3.6.1.4.1.5504.5.14.1.3.1.2
The row status for the port config table.
Status: current Access: read-create
OBJECT-TYPE    
  ZhoneRowStatus  

zhoneGponPortConfigMulticast 1.3.6.1.4.1.5504.5.14.1.3.1.3
Specifies whether this is a multicast or unicast port. If unicast, only one onu may be given, and the unicast-onu-id field is used. If multicast is true, then the multicast-onu-ids is used to name the onus.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneGponPortConfigEncrypted 1.3.6.1.4.1.5504.5.14.1.3.1.4
Specifies whether port-id PLOAM messages are encrypted. Must be false if multicast.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneGponPortConfigDirection 1.3.6.1.4.1.5504.5.14.1.3.1.5
Direction of data for this port.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER down(1), up(2), bidirectional(3)  

zhoneGponPortConfigTrafficProfile 1.3.6.1.4.1.5504.5.14.1.3.1.6
Index of GEM Port traffic profile for this port. A zero value indicates no GEM Port traffic profile has been selected.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortConfigRowShelf 1.3.6.1.4.1.5504.5.14.1.3.1.7
This is a WRITE-ONLY variable used during port create/delete operations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortConfigRowSlot 1.3.6.1.4.1.5504.5.14.1.3.1.8
This is a WRITE-ONLY variable used during port create/delete operations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortConfigRowOlt 1.3.6.1.4.1.5504.5.14.1.3.1.9
This is a WRITE-ONLY variable used during port create/delete operations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortConfigRowPort 1.3.6.1.4.1.5504.5.14.1.3.1.10
This is a WRITE-ONLY variable used during port create/delete operations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortConfigRowTrafficProfile 1.3.6.1.4.1.5504.5.14.1.3.1.11
This is a WRITE-ONLY variable used during port create/delete operations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortConfigRowOnuId 1.3.6.1.4.1.5504.5.14.1.3.1.12
The subPort of the ONU on which this GEM port is to be stacked. This is a write-only variable during row create.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortConfigTrafficManagementProfileIndex 1.3.6.1.4.1.5504.5.14.1.3.1.13
This object points to the associated Traffic Management profile. If there is no traffic control for the GEM port, set it to 0.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

zhoneGponAllocIdTable 1.3.6.1.4.1.5504.5.14.1.4
Table for management of upstream bandwidth
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponAllocIdEntry

zhoneGponAllocIdEntry 1.3.6.1.4.1.5504.5.14.1.4.1
Entry in the gpon allocId table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponAllocIdEntry  

zhoneGponAllocIdIndex 1.3.6.1.4.1.5504.5.14.1.4.1.1
An Id number which must be unique for a given OLT.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

zhoneGponAllocIdRowStatus 1.3.6.1.4.1.5504.5.14.1.4.1.2
Row status for the gpon alloc-id table.
Status: current Access: read-create
OBJECT-TYPE    
  ZhoneRowStatus  

zhoneGponAllocIdOnuId 1.3.6.1.4.1.5504.5.14.1.4.1.3
The onu number for this olt to which we are allocating bandwidth. Cannot be greater than number of onus for the olt. This field cannot be changed once the alloc-id has been created.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zhoneGponAllocIdGuaranteedBw 1.3.6.1.4.1.5504.5.14.1.4.1.4
Bandwidth guaranteed by this alloc-id. This value is specified in kilobits per second. Only multiples of 512 are allowed, and the value may not exceed 2621440 (i.e. 2.5 gigabits per second).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zhoneGponAllocIdTrafficClass 1.3.6.1.4.1.5504.5.14.1.4.1.5
Whether traffic is Constant Bit Rate or Unspecified Bit Rate.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cbr(1), ubr(2)  

zhoneGponAllocIdCompensated 1.3.6.1.4.1.5504.5.14.1.4.1.6
For CBR, indicates whether compensated.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneGponSerialNoTable 1.3.6.1.4.1.5504.5.14.1.5
Table of discovered serial numbers available for assignment to onus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponSerialNoEntry

zhoneGponSerialNoEntry 1.3.6.1.4.1.5504.5.14.1.5.1
Row in the Gpon onu serial number table
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponSerialNoEntry  

zhoneGponSerialNoOltLgIfIndex 1.3.6.1.4.1.5504.5.14.1.5.1.1
Linegroup ifIndex of the Olt on which serial number was discovered.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

zhoneGponSerialNoIndexId 1.3.6.1.4.1.5504.5.14.1.5.1.2
An identifying number, unique within olt, for this discovered onu serial number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponSerialNoVendorId 1.3.6.1.4.1.5504.5.14.1.5.1.3
The 4-character vendor id portion of serial number.
Status: current Access: read-only
OBJECT-TYPE    
  ZhoneAdminString Size(0..4)  

zhoneGponSerialNoVendorSpecific 1.3.6.1.4.1.5504.5.14.1.5.1.4
Vendor specific portion of the unassigned onu serial number, a string of decimal digits.
Status: current Access: read-write
OBJECT-TYPE    
  ZhoneAdminString Size(1..10)  

zhoneGponSerialNoTimeStamp 1.3.6.1.4.1.5504.5.14.1.5.1.5
Time, as ascii string, that the serial number was discovered.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

zhoneGponTrapPrefix 1.3.6.1.4.1.5504.5.14.1.6
Place-holder object for gpon traps, which must have a final digit of 0 in OID.
Status: current Access: read-only
OBJECT-IDENTITY    

zhoneGponTraps 1.3.6.1.4.1.5504.5.14.1.6.0
Traps raised by Gpon Rp.
Status: current Access: read-only
OBJECT-IDENTITY    

zhoneGponSerialNumberFound 1.3.6.1.4.1.5504.5.14.1.6.0.1
Notification that an ONU serial number has been discovered.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponSerialNumberLost 1.3.6.1.4.1.5504.5.14.1.6.0.2
Notification that a previously discovered ONU serial number is no longer available.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOnuLineStatusChange 1.3.6.1.4.1.5504.5.14.1.6.0.3
Description.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOmciOnuAlarmsTrap 1.3.6.1.4.1.5504.5.14.1.6.0.4
Current active alarms for an ONU entity. Alarms contained in the trap bindings will be for only one specific entity. If an entity alarm is not contained in the trap bindings then the alarm is either not active, not enabled, or not supported. If there are no alarms for the entity, then there will only be one alarm in the trap bindings and that alarm will have a value of zero and the alarm string will be 'None'.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOmciOnuDownloadStatusChange 1.3.6.1.4.1.5504.5.14.1.6.0.5
Trap will be raised for Image Download status changes.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOltOpticsAlarmsTrap 1.3.6.1.4.1.5504.5.14.1.6.0.6
Raised when SFP reports optics alarms condition for an SFP.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOnuError 1.3.6.1.4.1.5504.5.14.1.6.0.7
One of the ONU error conditions is present for the specified ONU. Report zhoneGponOnuStatusWord to indicate which error has occurred.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponRogueOnuTrap 1.3.6.1.4.1.5504.5.14.1.6.0.8
A rogue ONU has been detected on this OLT by the background process
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponRssiRogueOnuTrap 1.3.6.1.4.1.5504.5.14.1.6.0.9
Rogue ONU has been detected by RSSI process on this OLT.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOltStatusWordTrap 1.3.6.1.4.1.5504.5.14.1.6.0.10
Change in one of the gpol olt status word bits has been detected.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOnuAutoAssign 1.3.6.1.4.1.5504.5.14.1.6.0.11
Notification that an ONU ID has been auto assigned.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneGponOnuStatusTable 1.3.6.1.4.1.5504.5.14.1.7
Current status of onu as reported from Gpon driver.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOnuStatusEntry

zhoneGponOnuStatusEntry 1.3.6.1.4.1.5504.5.14.1.7.1
Row in the zhoneGponOnuStatusTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOnuStatusEntry  

zhoneGponOnuStatusWord 1.3.6.1.4.1.5504.5.14.1.7.1.1
Bit-encoded current onu status from gpon driver
Status: current Access: read-only
OBJECT-TYPE    
  BITS noAlarm(0), inactive(1), lossOfSignal(2), lossOfFrame(3), driftOfWindow(4), signalFail(5), signalDegrade(6), lossOfGemChanDelin(7), remoteDefect(8), transmitterFailure(9), startUpFailure(10), lossOfAck(11), dyingGasp(12), lossOfPloamSync(13), messageError(14), physEquipError(15), bit16notUsed(16), bit17notUsed(17), excessiveBipErrorsOnuDisabled(18), excessiveBipErrorsOnuNotDisabled(19), usRxPowerErrorOnuDisabled(20), usRxPowerErrorOnuNotDisabled(21), rogueOnu(22), manualOnuRebooted(23)  

zhoneGponOnuOmciState 1.3.6.1.4.1.5504.5.14.1.7.1.2
Current configuration status for ONU. 1. queued for configuration (waiting) 2. transitional state before configuration (pending) 3. in process of configuration (config) 4. unspecified error (error) 5. configuration successful (done) 6. image download in progress (download) 7. image download aborted (aborted) 8. state cannot be determined (unknown) 9. ONU is down (down) 10. no configuration has been attempted (noConfig) 11. ONU unreachable for RG configuration (rgComError) 12. Some RG commands failed, may impact service (rgServiceSetupErr) 13. OMCI configuration failed (omciFailed) 14. OMCI failed and also ONU unreachable for RG (omciErrAndRgComErr) 15. OMCI failed and also RG commands failed (omciErrAndRgServErr) 16. Some post-config commands failed (postCfgError) 17. OMCI failed and also some post-config commands failed (omciErrAndPostCfgErr)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER waiting(1), pending(2), config(3), error(4), done(5), download(6), aborted(7), unknown(8), down(9), noConfig(10), rgComError(11), rgServiceSetupErr(12), omciFailed(13), omciErrAndRgComErr(14), omciErrAndRgServErr(15), postCfgError(16), omciErrAndPostCfgErr(17)  

zhoneGponOnuOpticRssi 1.3.6.1.4.1.5504.5.14.1.7.1.3
RSSI power of the SFP per ONU. The value is in tenths of dB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -600..200  

zhoneGponOntRxPower 1.3.6.1.4.1.5504.5.14.1.7.1.4
Rx Power as reported by the ONT. The value is in tenths of dB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -600..200  

zhoneGponOntVersion 1.3.6.1.4.1.5504.5.14.1.7.1.5
This object defines the version of the ONT as defined by the vendor. The character value '0' indicates that the version information is not available or applicable.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..14)  

zhoneGponOnuDistance 1.3.6.1.4.1.5504.5.14.1.7.1.6
Distance from Olt to Ont in meters, as computed from Eqd.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneOnuOmciMEProfileTable 1.3.6.1.4.1.5504.5.14.1.8
Table containing the OMCI commands for the Managed Entities (ME) on an ONU. The following 'how to' examples demonstrate access of the object zhoneOnuOmciMEOmciCommands. How to create ME profile: 1. Determine ME profile instance 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = create zhoneOnuOmciMEProfileName.aaa = ME profile name zhoneOnuOmciMEProfileFilename.aaa = How to update existing ME profile from a file: 1. Determine ME profile instance 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = import zhoneOnuOmciMEProfileName.aaa = ME profile name zhoneOnuOmciMEProfileFilename.aaa = How to extract ME profile into a file: 1. Determine ME profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = export zhoneOnuOmciMEProfileFilename.aaa = 3. The file now exists on uplink file system How to delete ME profile: 1. Determine ME profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciMEProfileRowStatus.aaa = destroy
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneOnuOmciMEProfileEntry

zhoneOnuOmciMEProfileEntry 1.3.6.1.4.1.5504.5.14.1.8.1
Row in the ME Profile table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneOnuOmciMEProfileEntry  

zhoneOnuOmciMEProfileIndex 1.3.6.1.4.1.5504.5.14.1.8.1.1
A unique index for each row entry (1..n).
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneOnuOmciMEProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.8.1.2
Row status for the Me profile entry. Not really used for the configuration on the ONUs
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER active(1), create(2), destroy(3), export(4), import(5), append(6), revert(7)  

zhoneOnuOmciMEProfileName 1.3.6.1.4.1.5504.5.14.1.8.1.3
Name given to each row entry in the ME Profile table. The name must contain ascii printable characters and cannot contain blanks or forward-slash characters. The name must be null-terminated and the null character is included in the object data length. The name must be unique in the ME profiles.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciMEProfileOmciCommands 1.3.6.1.4.1.5504.5.14.1.8.1.4
Contains the set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss. This object cannot be accessed directly. See the comments section for zhoneOnuCmciMEProfileTable on how to acces this object.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64000)  

zhoneOnuOmciMEProfileFileName 1.3.6.1.4.1.5504.5.14.1.8.1.5
Name of file to be loaded into profile. This object is write-only and is not preserved.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciGenericProfileTable 1.3.6.1.4.1.5504.5.14.1.9
Table containing Generic OMCI commands for an ONU. The Generic profile is 'created' from an existing ME profile. During this operation, the 'variable' defintions from the ME profile are extracted from the ME profile and placed into the Generic profile. The Generic profile is 'updated' from a file placed into the uplink's file system. The following 'how to' examples demonstrate access of the object zhoneOnuOmciGenericOmciCommands. How to create Generic profile from ME profile: 1. Determine Generic profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = create zhoneOnuOmciGenericProfileName.aaa = profile name zhoneOnuOmciGenericProfileMESrcProfileName = ME profile source 3. Profile is now created and the profile will not contain any variables and values. How to update existing Generic profile from a file: 1. Determine Generic profile instance 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = import zhoneOnuOmciGenericProfileFileName.aaa = How to extract Generic profile into a file: 1. Determine ME profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = export zhoneOnuOmciGenericProfileFilename.aaa = 3. The file now exists on uplink file system How to delete Generic profile: 1. Determine Generic profile instance 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = destroy
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneOnuOmciGenericProfileEntry

zhoneOnuOmciGenericProfileEntry 1.3.6.1.4.1.5504.5.14.1.9.1
Row in the OMCI Generic Profile table
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneOnuOmciGenericProfileEntry  

zhoneOnuOmciGenericProfileIndex 1.3.6.1.4.1.5504.5.14.1.9.1.1
A unique index for each row entry ( 1..n ).
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneOnuOmciGenericProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.9.1.2
Row status for the Generic profile entry. Not really used for the configuration of the ONUs
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER active(1), create(2), destroy(3), export(4), import(5)  

zhoneOnuOmciGenericProfileName 1.3.6.1.4.1.5504.5.14.1.9.1.3
Name given to each row entry in the Generic Profile table. The name must contain ascii printable characters and cannot contain blanks or forward-slash characters. The name must be null-terminated and the null character is included in the object data length. The name must be unique in the Generic profiles.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciGenericProfileOmciCommands 1.3.6.1.4.1.5504.5.14.1.9.1.4
Contains the generic set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..15000)  

zhoneOnuOmciGenericProfileMESrcProfileName 1.3.6.1.4.1.5504.5.14.1.9.1.5
Name of ME profile used to create the Generic profile. The value for this object is only initialized when the profile is created.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciGenericProfileFileName 1.3.6.1.4.1.5504.5.14.1.9.1.6
Name of file to be loaded into profile. This object is write-only and is not preserved.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciSpecificProfileTable 1.3.6.1.4.1.5504.5.14.1.10
Table containing Specific OMCI commands for an ONU. The Specific profile is 'created' from existing ME and Generic profiles. During this operation, the 'variable' defintions from the ME and Generic profile are extracted from the profiles and placed into the Specific profile. The ME and Generic profile names are extracted from the ONU's Olt/Onu config profile. The Specific profile is 'updated' from a file placed into the uplink's file system. The following 'how to' examples demonstrate access of the object zhoneOnuOmciSpecificOmciCommands. How to create Specific profile from ME and Generic profiles: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciSpecificProfileRowStatus.aaa = create zhoneOnuOmciSpecificProfileFileName = 3. The profile is now created and the omciCommands contents have been placed into . The name of the ME profile used to create the Speofic profile is installed into zhoneOnuOmciSpecificProfileMESrcProfile. How to update existing Specific profile from a file: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Place file into uplink file system 3. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = import zhoneOnuOmciGenericProfileFileName.aaa = How to extract Specific profile into a file: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = export zhoneOnuOmciGenericProfileFilename.aaa = 3. The file now exists on uplink file system How to delete Specific profile: 1. Determine Specific profile instance (from ONU's ifIndex) 2. Issue single SNMP set command containing the following: zhoneOnuOmciGenericProfileRowStatus.aaa = destroy
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneOnuOmciSpecificProfileEntry

zhoneOnuOmciSpecificProfileEntry 1.3.6.1.4.1.5504.5.14.1.10.1
Row in the OMCI Specific Profile table
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneOnuOmciSpecificProfileEntry  

zhoneOnuOmciSpecificProfileIndex 1.3.6.1.4.1.5504.5.14.1.10.1.1
A unique index for each row entry. The index value corresponds to the ifIndex of the ONU which uses this profile.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

zhoneOnuOmciSpecificProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.10.1.2
Row status for the Specific Profile entry. Not really used for the configuration of the ONUs
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER active(1), create(2), destroy(3), export(4), import(5)  

zhoneOnuOmciSpecificProfileOmciCommands 1.3.6.1.4.1.5504.5.14.1.10.1.3
Contains the Specific set of OMCI commands and the variable substitutions used in configuring the ONUs. This object will go through some character substitution before being inserted into the database so the maximum string size will not be available. Available string size will vary based on string contents but expect about 10 percent loss.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..8000)  

zhoneOnuOmciSpecificProfileMESrcProfileName 1.3.6.1.4.1.5504.5.14.1.10.1.4
Name of ME profile used to create the Specific profile. The value for this object is only initialized when the profile is created.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciSpecificProfileFileName 1.3.6.1.4.1.5504.5.14.1.10.1.5
Name of file to be loaded into profile. This object is write-only and is not preserved.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneGponOmciOnuAlarmsTable 1.3.6.1.4.1.5504.5.14.1.11
A table of all GPON OMCI ONU alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOmciOnuAlarmsEntry

zhoneGponOmciOnuAlarmsEntry 1.3.6.1.4.1.5504.5.14.1.11.1
An entry for each ONU in the zhoneGponOmciOnuAlarmsTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOmciOnuAlarmsEntry  

zhoneGponOmciOnuAlarmsText 1.3.6.1.4.1.5504.5.14.1.11.1.1
This is a long ascii string which contains the GPON OMCI ONU alarms. Each line of text in this string has the following format: aaa,bbb,ccc,'aaaStr,'bbbStr',d where aaa : ME classId ( numeric decimal value ) bbb : alarm index ( numeric decimal value ) ccc : entityId ( numeric decimal value ) aaaStr : string version of ME name bbbStr : string version of alarm name d : alarm severity ( 1=critical, 2=major, 3=minor, 4=warning ) The ME classId is the standard value from the 'Managed entity identifiers' table of G984.4. The alarm index is the zero-based index (G984.4 or G983.2) within the ME class. the entityId is the physical port number on the ONT. Here is a sample: 11,0,513,'PptpEthUni','LanLos',2 256,1,0,'OntG','PoweringAlarm',3 If this string has zero length then there are no active alarms. If this string has a single entry with a classId of 65535 then the alarm collection failed. WARNING! In this description, replace the sinqle quote characters with double quote characters! The Zhone scripts have problems with double quote characters!
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16000)  

zhoneGponTrafficProfileTable 1.3.6.1.4.1.5504.5.14.1.12
A table of the GPON GEM Port Traffic profiles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponTrafficProfileEntry

zhoneGponTrafficProfileEntry 1.3.6.1.4.1.5504.5.14.1.12.1
Row in the zhoneGponPortTrafProfileTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponTrafficProfileEntry  

zhoneGponTrafficProfileIndex 1.3.6.1.4.1.5504.5.14.1.12.1.1
Used to index an entry in the GEM port traffic profile table
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponTrafficProfileRowStatus 1.3.6.1.4.1.5504.5.14.1.12.1.2
The row status for the GEM Port Traffic profile.
Status: current Access: read-create
OBJECT-TYPE    
  ZhoneRowStatus  

zhoneGponTrafficProfileGuaranteedUpstreamBw 1.3.6.1.4.1.5504.5.14.1.12.1.3
Bandwidth guaranteed by this alloc-id. This value is specified in kilobits per second. Only multiples of 512 are allowed, and the value may not exceed 2621440 (i.e. 2.5 gigabits per second).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..1048576  

zhoneGponTrafficProfileClass 1.3.6.1.4.1.5504.5.14.1.12.1.4
Whether traffic is Constant Bit Rate or Unspecified Bit Rate.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cbr(1), ubr(2)  

zhoneGponTrafficProfileCompensated 1.3.6.1.4.1.5504.5.14.1.12.1.5
For CBR, indicates whether compensated.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneGponTrafficProfileShared 1.3.6.1.4.1.5504.5.14.1.12.1.6
TRUE if the GEM Port which uses this traffic descriptor shares and allocation ID with another GEM port. FALSE otherwise. When used more than once in the same ONU, the GEM ports are assigned the same alloc-id value.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneGponTrafficProfileDbaEnabled 1.3.6.1.4.1.5504.5.14.1.12.1.7
A flag to indicate if dynamic or static bandwidth allocation is used. The default value of DbaEnabled is false.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneGponTrafficProfileDbaFixedUsUbrBw 1.3.6.1.4.1.5504.5.14.1.12.1.8
Fixed UBR bandwidth will be always allocated UBR bandwidth. The min values of Fixed Ubr bandwidth can be 0 or 128kilo bits per second.Only multiples of 64 kilobits per second are allowed.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..1048576  

zhoneGponTrafficProfileDbaFixedUsCbrBw 1.3.6.1.4.1.5504.5.14.1.12.1.9
Fixed CBR bandwidth will be always allocated CBR bandwidth. The min value of Fixed Cbr bandwidth can be 0 or 512 kilobits per second.Only multiples of 64 kilo bits per second are allowed.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..454208  

zhoneGponTrafficProfileDbaAssuredUsBw 1.3.6.1.4.1.5504.5.14.1.12.1.10
DBA Assured bandwidth will be allocated when traffic demand exists. The min value of Assured bandwidth can be 0 or 256 kilobits per second. Only multiples of 64 kilo bits per second are allowed.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..1048576  

zhoneGponTrafficProfileMaxUsBw 1.3.6.1.4.1.5504.5.14.1.12.1.11
The Max Bandwidth value should be larger or equal to the sum of Fixed UBR, Fixed CBR and Assured.The increments should be done in the order of 64 kilobits per second.The default value of maximum bandwidth is 0.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..1048576  

zhoneGponTrafficProfileExtraUsBwType 1.3.6.1.4.1.5504.5.14.1.12.1.12
Extra Bandwidth = MaxBw - (Assured+FixedUbr+FixedCbr) The two Extra bandwidth types supported are : 1.nonassured 2.besteffort By default the value is nonassured.Nonassured has higher priority for getting unused bandwidth than besteffort.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nonassured(1), besteffort(2)  

zhoneGponPortStatusTable 1.3.6.1.4.1.5504.5.14.1.13
Current status of GEM port as reported from Gpon driver.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponPortStatusEntry

zhoneGponPortStatusEntry 1.3.6.1.4.1.5504.5.14.1.13.1
Row in the zhoneGponPortStatusTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponPortStatusEntry  

zhoneGponPortStatusAllocId 1.3.6.1.4.1.5504.5.14.1.13.1.1
The current dynamic alloc-id value for the GEM port.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponPortStatusDbaStatus 1.3.6.1.4.1.5504.5.14.1.13.1.2
The current DBA status for this GEM port. DBA status reporting is on a per-ONU basis. All GEM ports on the ONU will report the same value. Possible values: sr - DBA type is SR and there is no error nsr - DBA type is NSR and there is no error nsrError - DBA type is NSR and there is an error or the ONU does not support NSR notEnabled - DBA has been disabled notAvailable - cannot communicate with ONU notAdded - ONU is not added to the OLT error - internal error prevents data collection
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sr(1), nsr(2), nsrError(3), notEnabled(4), notAvailable(5), notAdded(6), error(7)  

zhoneGponOmciStatsCurrentTable 1.3.6.1.4.1.5504.5.14.1.14
Table of current-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOmciStatsCurrentEntry

zhoneGponOmciStatsCurrentEntry 1.3.6.1.4.1.5504.5.14.1.14.1
Row in zhoneGponOmciStatsCurrentTable. Each row retrieves counters for the current 15-minute interval for one managed entity on one logical port of one ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOmciStatsCurrentEntry  

zhoneGponOmciStatsCurrentMEId 1.3.6.1.4.1.5504.5.14.1.14.1.1
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciStatsCurrentLogicalPort 1.3.6.1.4.1.5504.5.14.1.14.1.2
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciStatsCurrentText 1.3.6.1.4.1.5504.5.14.1.14.1.3
Blob of statistics information returned. Format is: PhysPort,I1,A1,I2,A2,...In,An where PhysPort - physical port ID value Ii = attribute index (0-15, ascii-coded decimal integer) within ME according to G984,4 standard. Ai = attribute value (counter, ascii-coded decimal integer) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

zhoneGponOmciStatsPreviousTable 1.3.6.1.4.1.5504.5.14.1.15
Table of previous-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOmciStatsPreviousEntry

zhoneGponOmciStatsPreviousEntry 1.3.6.1.4.1.5504.5.14.1.15.1
Row in zhoneGponOmciStatsPreviousTable. Each row retrieves counters for the last completed 15-minute interval for one managed entity on one logical port of one ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOmciStatsPreviousEntry  

zhoneGponOmciStatsPreviousMEId 1.3.6.1.4.1.5504.5.14.1.15.1.1
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciStatsPreviousLogicalPort 1.3.6.1.4.1.5504.5.14.1.15.1.2
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciStatsPreviousText 1.3.6.1.4.1.5504.5.14.1.15.1.3
Blob of statistics information returned. Format is: PhysPort,I1,A1,I2,A2,...In,An where PhysPort - physical port ID value Ii = attribute index (0-15, ascii-coded decimal integer) within ME according to G984,4 standard. Ai = attribute value (counter, ascii-coded decimal integer) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

zhoneGponOmciStatusTable 1.3.6.1.4.1.5504.5.14.1.16
Table of current-interval statistics gathered via OMCI from ONT's as specified in the ME profiles used by that ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOmciStatusEntry

zhoneGponOmciStatusEntry 1.3.6.1.4.1.5504.5.14.1.16.1
Row in zhoneGponOmciStatsCurrentTable. Each row retrieves counters for the current 15-minute interval for one managed entity on one logical port of one ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOmciStatusEntry  

zhoneGponOmciStatusMEId 1.3.6.1.4.1.5504.5.14.1.16.1.1
This is the ID of the managed entity in the ITU G984.4 standard for the OMCI statistics we want to read.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciStatusLogicalPort 1.3.6.1.4.1.5504.5.14.1.16.1.2
This specifies which entity on the ONT we want the statistics for. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciStatusText 1.3.6.1.4.1.5504.5.14.1.16.1.3
Blob of status information returned. Format is: PhysPort,attrId1,attrName1,attrNumValue1,attrStrValue1... attrIdn,attrNamen,attrNumValuen,attrStrValuen where PhysPort - physical port ID value attrIdn = index number (0-15) of the attribute within the the ME (ascii decimal) attrNamen = name of the attribute (returned by OCS) attrNumValuen = value of the attribute (ascii decimal) attrStrValuen = interpreted value ( 'up', 'down', etc ) n = number of attributes returned = number requested. Maximum number of attributes per ME is 16.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..512)  

zhoneGponOmciOnuRebootTable 1.3.6.1.4.1.5504.5.14.1.17
Table of objects used to reboot an ONU via the OMCI.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOmciOnuRebootEntry

zhoneGponOmciOnuRebootEntry 1.3.6.1.4.1.5504.5.14.1.17.1
A single entry in the table
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOmciOnuRebootEntry  

zhoneGponOmciOnuReboot 1.3.6.1.4.1.5504.5.14.1.17.1.1
Set this object to 'reboot to reboot an ONU. The reboot command is sent to the ONU over the OMCI. Successful transmission of the reboot command to the ONU does no guarantee the ONU will reboot. The ONU may be in a fatal lockup which prevents the processing of the reboot command.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), reboot(1)  

zhoneGponOmciOnuPortAdminTable 1.3.6.1.4.1.5504.5.14.1.18
Table of objects used to configure the admin state of a physical port on an ONU.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOmciOnuPortAdminEntry

zhoneGponOmciOnuPortAdminEntry 1.3.6.1.4.1.5504.5.14.1.18.1
A single entry in the table
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOmciOnuPortAdminEntry  

zhoneGponOmciOnuPortAdminMEId 1.3.6.1.4.1.5504.5.14.1.18.1.1
This is the ID of the managed entity in the ITU G984.4 standard.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciOnuPortAdminLogicalPort 1.3.6.1.4.1.5504.5.14.1.18.1.2
This specifies which entity on the ONT we want. This is a logical number (1,2,...) which is translated according to the ME profile into an entity ID which is included in the command to the ONT.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

zhoneGponOmciOnuPortAdminState 1.3.6.1.4.1.5504.5.14.1.18.1.3
This object is used to place an ONU physical port in a DOWN or UP state. This state is a configuration parameter and is preserved.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), up(1), down(2)  

zhoneGponOmciOnuPortAdminAutoDetect 1.3.6.1.4.1.5504.5.14.1.18.1.4
This object is used to set the auto detection rate of an ONU physical port.This state is a configuration parameter and is preserved.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), auto(1), tenFull(2), hundredFull(3), thousandFull(4), tenAuto(5), tenHalf(6), hundredHalf(7), thousandHalf(8), thousandAuto(9), autoFull(10), autoHalf(11), hundredAuto(12)  

zhoneGponOmciOnuImageUpgradeTable 1.3.6.1.4.1.5504.5.14.1.19
This table is used to perform ONU software upgrades. There is one table entry for each ONU. Each ONU is addressed by it's ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOmciOnuImageUpgradeEntry

zhoneGponOmciOnuImageUpgradeEntry 1.3.6.1.4.1.5504.5.14.1.19.1
An entry for one ONU.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOmciOnuImageUpgradeEntry  

zhoneGponOmciOnuImageUpgradeAction 1.3.6.1.4.1.5504.5.14.1.19.1.1
Which software upgrade action to perform.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), download(1), activate(2), commit(3), downloadActivate(4), downloadActivateCommit(5), abortDownload(6), activateCommit(7)  

zhoneOnuOmciImageUpgradeFilename 1.3.6.1.4.1.5504.5.14.1.19.1.2
Name of file to be loaded downloaded to ONU. Required on download actions.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneGponOmciOnuImageUpgradePartition 1.3.6.1.4.1.5504.5.14.1.19.1.3
Optional on all actions. Indicates which partition or 'none'in which case default is to use inactive partition for download or activate action, or to the uncommitted partion for commit action. On a read, returns the partition used for current or latest upgrade.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), partitionNumber0(1), partitionNumber1(2)  

zhoneOnuOmciImageUpgradeImageVersionPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.4
Version information for s/w image loaded into partition 0.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciImageUpgradeImageVersionPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.5
Version information for s/w image loaded into partition 1.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

zhoneOnuOmciImageUpgradeIsCommittedPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.6
Current commit status for partition 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), true(1), false(2)  

zhoneOnuOmciImageUpgradeIsCommittedPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.7
Current commit status for partition 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), true(1), false(2)  

zhoneOnuOmciImageUpgradeIsActivatedPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.8
Current activated status for partition 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), true(1), false(2)  

zhoneOnuOmciImageUpgradeIsActivatedPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.9
Current activated status for partition 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), true(1), false(2)  

zhoneOnuOmciImageUpgradeIsValidPartition0 1.3.6.1.4.1.5504.5.14.1.19.1.10
Current valid status for partition 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), true(1), false(2)  

zhoneOnuOmciImageUpgradeIsValidPartition1 1.3.6.1.4.1.5504.5.14.1.19.1.11
Current valid status for partition 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), true(1), false(2)  

zhoneOnuOmciImageUpgradeDownloadStatus 1.3.6.1.4.1.5504.5.14.1.19.1.12
Current s/w image download status.
Status: current Access: read-only
OBJECT-TYPE    
  OnuUpgradeState  

zhoneGponOmciOnuImageUpgradeModel 1.3.6.1.4.1.5504.5.14.1.19.1.13
Model id read from this onu.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

zhoneGponOmciOnuImageUpgradeStartTime 1.3.6.1.4.1.5504.5.14.1.19.1.14
Start time, as ascii string, of most recent upgrade.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

zhoneGponOmciOnuImageUpgradeWillBeActivated 1.3.6.1.4.1.5504.5.14.1.19.1.15
If true, the downloaded image will be activated when download completes.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneGponOmciOnuImageUpgradeWillBeCommitted 1.3.6.1.4.1.5504.5.14.1.19.1.16
If true, this image will be committed on successful activation.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneGponOmciOnuImageUpgradeType 1.3.6.1.4.1.5504.5.14.1.19.1.17
Indicates the reason for the upgrade.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), manual(1), auto(2), bulk(3)  

zhoneGponOmciOnuImageDownloadProgressPercentage 1.3.6.1.4.1.5504.5.14.1.19.1.18
Image download progress. This object is only valid during image download.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

zhoneGponOmciOnuImageUpgradeMethod 1.3.6.1.4.1.5504.5.14.1.19.1.19
The download method used for upgrading this ONU. TFTP is used where possible, else OMCI (default).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER omci(1), tftp(2)  

zhoneGponOltStatusTable 1.3.6.1.4.1.5504.5.14.1.20
Current Status of OLT as reported from the Gpon Driver.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOltStatusEntry

zhoneGponOltStatusEntry 1.3.6.1.4.1.5504.5.14.1.20.1
Row in the zhoneGponOltStatusTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOltStatusEntry  

zhoneGponOltOpticTemperature 1.3.6.1.4.1.5504.5.14.1.20.1.1
Internally measured Tranceiver Temperature of the OLT in Celcius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -128..128  

zhoneGponOltOpticVoltage 1.3.6.1.4.1.5504.5.14.1.20.1.2
Internally measured Tranceiver Supply Voltage of the OLT in Volts. The measured value will be in the order of hundredths of Volts.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..655  

zhoneGponOltOpticTxBiasCurrent 1.3.6.1.4.1.5504.5.14.1.20.1.3
Measured Tx Bias current per OLT in milli Amperes.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..131  

zhoneGponOltOpticTxPower 1.3.6.1.4.1.5504.5.14.1.20.1.4
Measured Tx Output Power of the OLT in dB. The measured value will be in tenths of dB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -600..200  

zhoneGponOltOpticStatus 1.3.6.1.4.1.5504.5.14.1.20.1.5
When the End Of Life(EOL) Alarm bit is set an alarm will be raised. Alarm is set at about 150% of original current.Alarm will be level Major. It will be cleared when the SFP is replaced, or when the Alarm bit is cleared. Warning indication will be provided when user asks for status. Warning is set when EOL is at about 130% original current.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), warning(2), alarm(4), sfpnotpresent(8), oltactive(16)  

zhoneGponOltOpticAlarms 1.3.6.1.4.1.5504.5.14.1.20.1.6
Bitmap of alarm conditions present, as reported from the SFP.
Status: current Access: read-only
OBJECT-TYPE    
  BITS tempHigh(0), tempLow(1), vccHigh(2), vccLow(3), txBiasHigh(4), txBiasLow(5), txPwrHigh(6), txPwrLow(7), rxPwrHigh(8), rxPwrLow(9)  

zhoneGponOltStatusWord 1.3.6.1.4.1.5504.5.14.1.20.1.7
The bit-coded OLT status word.
Status: current Access: read-only
OBJECT-TYPE    
  BITS noAlarm(0), notused1(1), notused2(2), notused3(3), notused4(4), notused5(5), lossOfSignal(6), notused7(7), notused8(8), outOfService(9), rogueOnu(10), rogueOnuRssi(11), sgmiiGeLinkDown(12)  

zhoneGponOltConfiguredOnuCount 1.3.6.1.4.1.5504.5.14.1.20.1.8
Count of the ONUs on this OLT where onu-added = TRUE.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltActiveOnuCount 1.3.6.1.4.1.5504.5.14.1.20.1.9
Number of ONUs on this OLT currently in operational state UP.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaStatusTable 1.3.6.1.4.1.5504.5.14.1.21
Current status of OLT DBA as reported from CAC.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOltDbaStatusEntry

zhoneGponOltDbaStatusEntry 1.3.6.1.4.1.5504.5.14.1.21.1
Row in the zhoneGponOltDbaStatusTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOltDbaStatusEntry  

zhoneGponOltDbaTotalAvailableBw 1.3.6.1.4.1.5504.5.14.1.21.1.1
The Total Available DBA Bandwidth per OLT.The unit is Kilobits( 1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaTotalAvailableCompensatedCbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.2
The Total Available DBA Compensated CBR bandwidth per OLT. The unit is Kilobits(1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAllocatedUbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.3
The Total Available DBA Allocated UBR bandwidth per OLT. The unit is Kilobits(1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAllocatedCbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.4
The Total Available DBA Allocated CBR bandwidth per OLT. The unit is Kilobits(1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAllocatedCompensatedCbrBw 1.3.6.1.4.1.5504.5.14.1.21.1.5
The Total Available DBA Allocated CBR Compensated bandwidth per OLT. The unit is Kilobits(1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAllocatedAssuredBw 1.3.6.1.4.1.5504.5.14.1.21.1.6
The Total Available DBA Allocated Assured bandwidth per OLT. The unit is Kilobits(1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAllocatedNonAssuredBw 1.3.6.1.4.1.5504.5.14.1.21.1.7
The Total Available DBA Allocated Non Assured bandwidth per OLT. The unit is Kilobits(1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAllocatedBestEffortBw 1.3.6.1.4.1.5504.5.14.1.21.1.8
The Total Available DBA Allocated Best Effort bandwidth per OLT. The unit is Kilobits(1000 bits).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaMaxAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.9
Maximum number of alloc-Ids supported by this OLT.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAvailAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.10
Total number of available alloc-Ids for this OLT.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaUsedAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.11
Total number of alloc-Ids in use for this OLT.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaMaxDbaAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.12
Maximum number of DBA alloc-Ids supported by this OLT.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaAvailDbaAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.13
Total number of available DBA alloc-Ids for this OLT.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaUsedDbaAllocIds 1.3.6.1.4.1.5504.5.14.1.21.1.14
Total number of DBA alloc-Ids in use for this OLT.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaTotalOltGemPorts 1.3.6.1.4.1.5504.5.14.1.21.1.15
Total number GEM Ports currently on this OLT.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltDbaLastCacRc 1.3.6.1.4.1.5504.5.14.1.21.1.16
This object contains the result code of the last GPON CAC request for the OLT.
Status: current Access: read-only
OBJECT-TYPE    
  GponCacRc  

zhoneGponUpgradeByStateTable 1.3.6.1.4.1.5504.5.14.1.22
Information about onu upgrade.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponUpgradeByStateEntry

zhoneGponUpgradeByStateEntry 1.3.6.1.4.1.5504.5.14.1.22.1
Row in onu upgrade table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponUpgradeByStateEntry  

zhoneGponUpgradeOlt 1.3.6.1.4.1.5504.5.14.1.22.1.1
Olt number on the card.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..32  

zhoneGponUpgradeOnu 1.3.6.1.4.1.5504.5.14.1.22.1.2
Onu number within olt.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..128  

zhoneGponUpgradeModel 1.3.6.1.4.1.5504.5.14.1.22.1.3
Model ID returned from this Onu.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

zhoneGponUpgradeStartTime 1.3.6.1.4.1.5504.5.14.1.22.1.4
Last upgrade start time, as ascii string
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

zhoneGponUpgradeIfIndex 1.3.6.1.4.1.5504.5.14.1.22.1.5
Onu ifIndex
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

zhoneGponUpgradeByStateOnuState 1.3.6.1.4.1.5504.5.14.1.22.1.6
The actual upgrade state of the onu.
Status: current Access: read-only
OBJECT-TYPE    
  OnuUpgradeState  

zhoneGponUpgradeByStateWillBeActivated 1.3.6.1.4.1.5504.5.14.1.22.1.7
If true, the image will be activated if download is successful.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneGponUpgradeByStateWillBeCommitted 1.3.6.1.4.1.5504.5.14.1.22.1.8
If true, image will be committed after successful activation.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneGponUpgradeByStateUpgradeType 1.3.6.1.4.1.5504.5.14.1.22.1.9
Indicates the reason for the upgrade.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), manual(1), auto(2), bulk(3)  

zhoneGponUpgradeByStatePartition 1.3.6.1.4.1.5504.5.14.1.22.1.10
If upgrade has been requested, this is the image partition of the latest upgrade.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), partitionNumber0(1), partitionNumber1(2)  

zhoneGponUpgradeProgressPercentage 1.3.6.1.4.1.5504.5.14.1.22.1.11
Image download progress. This object is only valid during image download.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

zhoneGponUpgradeByStateMethod 1.3.6.1.4.1.5504.5.14.1.22.1.12
The download method used for upgrading this ONU. TFTP is used where possible, else OMCI (default).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER omci(1), tftp(2)  

zhoneGponCmd 1.3.6.1.4.1.5504.5.14.1.23
OBJECT IDENTIFIER    

zhoneGponCmdOperation 1.3.6.1.4.1.5504.5.14.1.23.1
GPON Command operation. This object must be supplied with each operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER onuApply(1), onuResync(2), onuReboot(3), onuSet2default(4), onuEnableAutoCfg(5), onuDisableAutoCfg(6)  

zhoneGponCmdFilterMask 1.3.6.1.4.1.5504.5.14.1.23.2
GPON Command operation filter. This object must be supplied with each operation.
Status: current Access: read-write
OBJECT-TYPE    
  BITS filterShelf(0), filterSlot(1), filterOlt(2), filterOnu(3)  

zhoneGponCmdShelf 1.3.6.1.4.1.5504.5.14.1.23.3
GPON command 'SHELF' filter value. This parameter is for future use and is currently not supported.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1  

zhoneGponCmdSlot 1.3.6.1.4.1.5504.5.14.1.23.4
GPON command 'SLOT' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..32  

zhoneGponCmdOlt 1.3.6.1.4.1.5504.5.14.1.23.5
GPON command 'OLT' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

zhoneGponCmdOnu 1.3.6.1.4.1.5504.5.14.1.23.6
GPON command 'ONU' filter value. If this object is included in the SNMP packet then the associated filter must be enabled in the filter (zhoneGponCmdFilterMask).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

zhoneGponOltStatisticsTable 1.3.6.1.4.1.5504.5.14.1.24
Per OLT statistics gathered from Broadlight device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponOltStatisticsEntry

zhoneGponOltStatisticsEntry 1.3.6.1.4.1.5504.5.14.1.24.1
Per OLT statistics gathered from Broadlight device.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponOltStatisticsEntry  

zhoneGponOltStatisticsUpstreamValidGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.1
UpstreamValidGemFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamDiscardedFrames 1.3.6.1.4.1.5504.5.14.1.24.1.2
UpstreamDiscardedFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.3
UpstreamGemFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamOmciFrames 1.3.6.1.4.1.5504.5.14.1.24.1.4
UpstreamOmciFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamPloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.5
UpstreamPloamFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamIdlePloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.6
UpstreamIdlePloamFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamValidGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.7
DownstreamValidGemFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamDiscardedFrames 1.3.6.1.4.1.5504.5.14.1.24.1.8
DownstreamDiscardedFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamGemFrames 1.3.6.1.4.1.5504.5.14.1.24.1.9
DownstreamGemFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamOmciFrames 1.3.6.1.4.1.5504.5.14.1.24.1.10
DownstreamOmciFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamPloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.11
DownstreamPloamFrames counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamIdlePloamFrames 1.3.6.1.4.1.5504.5.14.1.24.1.12
DownstreamIdlePloamFrames counter.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamPonValidEthernetPkts 1.3.6.1.4.1.5504.5.14.1.24.1.13
DownstreamPonValidEthernetPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamPonCpuPkts 1.3.6.1.4.1.5504.5.14.1.24.1.14
DownstreamPonCpuPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTxBytes 1.3.6.1.4.1.5504.5.14.1.24.1.15
DownstreamTxBytes counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamPonValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.16
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamPonValidNotIdlePloams 1.3.6.1.4.1.5504.5.14.1.24.1.17
UpstreamPonValidNotIdlePloams counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamPonErrorPloams 1.3.6.1.4.1.5504.5.14.1.24.1.18
UpstreamPonErrorPloams counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamPonInvalidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.19
UpstreamPonInvalidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamDroppedPktsInactivePorts 1.3.6.1.4.1.5504.5.14.1.24.1.20
UpstreamDroppedPktsInactivePorts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamDroppedPloamsFifoFull 1.3.6.1.4.1.5504.5.14.1.24.1.21
UpstreamDroppedPloamsFifoFull counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.22
DownstreamTmValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmCrcPkts 1.3.6.1.4.1.5504.5.14.1.24.1.23
DownstreamTmCrcPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmDroppedCpuPkts 1.3.6.1.4.1.5504.5.14.1.24.1.24
DownstreamTmDroppedCpuPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmMacLookupMiss 1.3.6.1.4.1.5504.5.14.1.24.1.25
DownstreamTmMacLookupMiss counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmPktsForwardedFromHmToPon 1.3.6.1.4.1.5504.5.14.1.24.1.26
DownstreamTmPktsForwardedFromHmToPon counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmPktsDroppedGemPidNotEnabled 1.3.6.1.4.1.5504.5.14.1.24.1.27
DownstreamTmPktsDroppedGemPidNotEnabled counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ0ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.28
DownstreamTmQ0ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ0DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.29
DownstreamTmQ0DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ1ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.30
DownstreamTmQ1ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ1DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.31
DownstreamTmQ1DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ2ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.32
DownstreamTmQ2ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ2DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.33
DownstreamTmQ2DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ3ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.34
DownstreamTmQ3ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ3DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.35
DownstreamTmQ3DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ4ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.36
DownstreamTmQ4ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ4DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.37
DownstreamTmQ4DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ5ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.38
DownstreamTmQ5ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ5DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.39
DownstreamTmQ5DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ6ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.40
DownstreamTmQ6ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ6DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.41
DownstreamTmQ6DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ7ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.42
DownstreamTmQ7ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsDownstreamTmQ7DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.43
DownstreamTmQ7DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmDroppedCpuPkts 1.3.6.1.4.1.5504.5.14.1.24.1.44
UpstreamTmDroppedCpuPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmDroppedPktsCrcError 1.3.6.1.4.1.5504.5.14.1.24.1.45
UpstreamTmDroppedPktsCrcError counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmDroppedPktsSecurity 1.3.6.1.4.1.5504.5.14.1.24.1.46
UpstreamTmDroppedPktsSecurity counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmLearnFailures 1.3.6.1.4.1.5504.5.14.1.24.1.47
UpstreamTmLearnFailures counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ0ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.48
UpstreamTmQ0ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ0DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.49
UpstreamTmQ0DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ1ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.50
UpstreamTmQ1ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ1DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.51
UpstreamTmQ1DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ2ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.52
UpstreamTmQ2ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ2DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.53
UpstreamTmQ2DroppedPkts
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ3ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.54
UpstreamTmQ3ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ3DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.55
UpstreamTmQ3DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ4ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.56
UpstreamTmQ4ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ4DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.57
UpstreamTmQ4DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ5ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.58
UpstreamTmQ5ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ5DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.59
UpstreamTmQ5DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ6ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.60
UpstreamTmQ6ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ6DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.61
UpstreamTmQ6DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ7ValidPkts 1.3.6.1.4.1.5504.5.14.1.24.1.62
UpstreamTmQ7ValidPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsUpstreamTmQ7DroppedPkts 1.3.6.1.4.1.5504.5.14.1.24.1.63
UpstreamTmQ7DroppedPkts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponOltStatisticsClearStats 1.3.6.1.4.1.5504.5.14.1.24.1.64
Clear all statistics for the selected interface.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

zhoneGponUpstreamOntStatisticsTable 1.3.6.1.4.1.5504.5.14.1.25
Per ONT Upstream Statistics provided by Broadlight.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneGponUpstreamOntStatisticsEntry

zhoneGponUpstreamOntStatisticsEntry 1.3.6.1.4.1.5504.5.14.1.25.1
Per ONT Upstream Statistics provided by Broadlight.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneGponUpstreamOntStatisticsEntry  

zhoneGponUpstreamOntStatisticsUpstreamBipErrors 1.3.6.1.4.1.5504.5.14.1.25.1.1
UpstreamOntStatisticsUpstreamBipErrors counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsFecCorrectedBytes 1.3.6.1.4.1.5504.5.14.1.25.1.2
UpstreamOntStatisticsFecCorrectedBytes counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsFecCorrectedCodewords 1.3.6.1.4.1.5504.5.14.1.25.1.3
UpstreamOntStatisticsFecCorrectedCodewords counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsFecUncorrectedCodewords 1.3.6.1.4.1.5504.5.14.1.25.1.4
UpstreamOntStatisticsFecUncorrectedCodewords counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsTotalRxCodewords 1.3.6.1.4.1.5504.5.14.1.25.1.5
UpstreamOntStatisticsTotalRxCodewords counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsUnreceivedBursts 1.3.6.1.4.1.5504.5.14.1.25.1.6
UpstreamOntStatisticsUnreceivedBursts counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsBipErrors 1.3.6.1.4.1.5504.5.14.1.25.1.7
UpstreamOntStatisticsBipErrors counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsRemoteBipErrors 1.3.6.1.4.1.5504.5.14.1.25.1.8
UpstreamOntStatisticsRemoteBipErrors counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsDriftOfWindowIndications 1.3.6.1.4.1.5504.5.14.1.25.1.9
UpstreamOntStatisticsDriftOfWindowIndications counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsMessageErrorMessage 1.3.6.1.4.1.5504.5.14.1.25.1.10
UpstreamOntStatisticsMessageErrorMessage counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

zhoneGponUpstreamOntStatisticsClearStats 1.3.6.1.4.1.5504.5.14.1.25.1.11
Clear all statistics for the selected interface.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

zhoneGponOltConfigGroup 1.3.6.1.4.1.5504.9.1.10
GPON OLT Config group
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOnuConfigGroup 1.3.6.1.4.1.5504.9.1.11
GPON ONU Config group
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponPortConfigGroup 1.3.6.1.4.1.5504.9.1.12
GPON Port Config group
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponAllocIdGroup 1.3.6.1.4.1.5504.9.1.13
GPON Allocation ID group
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponSerialNoGroup 1.3.6.1.4.1.5504.9.1.14
GPON Serial Number group
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOnuStatusGroup 1.3.6.1.4.1.5504.9.1.15
GPON ONU Status group
Status: current Access: read-write
OBJECT-GROUP    

zhoneOnuOmciMeProfileGroup 1.3.6.1.4.1.5504.9.1.16
GPON OMCI ONU ME Profile group
Status: current Access: read-write
OBJECT-GROUP    

zhoneOnuOmciGenericProfileGroup 1.3.6.1.4.1.5504.9.1.17
GPON OMCI ONU Generic Profile group
Status: current Access: read-write
OBJECT-GROUP    

zhoneOnuOmciSpecificProfileGroup 1.3.6.1.4.1.5504.9.1.18
GPON OMCI ONU Specific Profile group
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOmciOnuAlarmsGroup 1.3.6.1.4.1.5504.9.1.19
GPON OMCI ONU Alarms group
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponTrapGroup 1.3.6.1.4.1.5504.9.1.20
Gpon Trap objects.
Status: current Access: read-write
NOTIFICATION-GROUP    

zhoneGponTrafficProfileGroup 1.3.6.1.4.1.5504.9.1.21
Gpon Traffic Profile objects.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponPortStatusGroup 1.3.6.1.4.1.5504.9.1.22
Gpon Port Status objects.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOmciStatusGroup 1.3.6.1.4.1.5504.9.1.24
Gpon Omci Status objects.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOmciOnuRebootGroup 1.3.6.1.4.1.5504.9.1.25
Gpon Omci Reboot objects.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOmciOnuPortAdminGroup 1.3.6.1.4.1.5504.9.1.26
Gpon Port Admin objects.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOmciOnuImageUpgradeGroup 1.3.6.1.4.1.5504.9.1.27
Group of ONU Image Upgrade objects
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOltStatusGroup 1.3.6.1.4.1.5504.9.1.28
GPON OLT Status Group.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponeOltDbaStatusGroup 1.3.6.1.4.1.5504.9.1.29
GPON OLT Dba Status Group.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponCmdGroup 1.3.6.1.4.1.5504.9.1.31
GPON Command objects
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponOltStatisticsGroup 1.3.6.1.4.1.5504.9.1.32
Gpon OLT Statistics objects.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponUpstreamOntStatisticsGroup 1.3.6.1.4.1.5504.9.1.33
Gpon Upstream ONT Statistics objects.
Status: current Access: read-write
OBJECT-GROUP    

zhoneGponDeprecated 1.3.6.1.4.1.5504.9.1.34
Gpon Deprecated objects.
Status: deprecated Access: read-write
OBJECT-GROUP