Defined Types
SensorUnits |
|
Sensor measurement unit types. Valid values are:
other(1) - a measure other than those listed below.
truthvalue(2) - value takes { true(1), false(2) }.
specialEnum(3) - value takes user defined enumerated values.
volts(4) - electrical potential.
celsius(5) - temperature.
rpm(6) - revolutions per minute. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
other(1), truthvalue(2), specialEnum(3), volts(4), celsius(5), rpm(6) |
|
SensorCode |
|
Interpretation of the current sensor value. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
ok(1), unknown(2), notInstalled(3), voltageLowWarning(4), voltageLowCritical(5), noPower(6), voltageHighWarning(7), voltageHighCritical(8), voltageHighSevere(9), temperatureHighWarning(10), temperatureHighCritical(11), temperatureHighSevere(12), fanSlowWarning(13), fanSlowCritical(14), fanStopped(15) |
|
ExpBase10 |
|
Exponent base 10 for the current sensor value.
For example '-1' means value*(1/10). |
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
-24..24 |
|
SensorValue |
|
For sensors that measure volts and celsius,
this item is a fixed point number.
For sensors that measure rpm, this item
can take only nonnegative values.
For sensors of type truthvalue, this item
can take only two values: true(1), false(2).
For sensors of type specialEnum, this item
can take any value. |
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
-1000000000..1000000000 |
|
SensorStatus |
|
Indicates the operational status of the sensor.
ok(1) means the agent can read the sensor value.
unavailable(2) means that the agent presently
can not report the sensor value.
nonoperational(3) means that the sensor is broken.
notInstalled(4) means that the sensor or device is not present. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
ok(1), unavailable(2), nonoperational(3), notInstalled(4) |
|
DeviceSensorValueEntry |
|
SEQUENCE |
|
|
|
|
deviceSensorIndex |
INTEGER |
|
|
deviceSensorTrapEnabled |
TruthValue |
|
|
deviceSensorUnits |
SensorUnits |
|
|
deviceSensorScale |
ExpBase10 |
|
|
deviceSensorValue |
SensorValue |
|
|
deviceSensorCode |
SensorCode |
|
|
deviceSensorStatus |
SensorStatus |
|
|
deviceSensorTimeStamp |
TimeStamp |
|
|
deviceSensorName |
DisplayString |
|
Defined Values
deviceSensorMIB |
1.3.6.1.4.1.3417.2.1 |
The sensor MIB is used to monitor
the values of sensors |
MODULE-IDENTITY |
|
|
|
deviceSensorValueEntry |
1.3.6.1.4.1.3417.2.1.1.1.1.1 |
An deviceSensorValueTable entry describes the
present reading of a sensor, the measurement units
and sensor operational status. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DeviceSensorValueEntry |
|
|
deviceSensorIndex |
1.3.6.1.4.1.3417.2.1.1.1.1.1.1 |
An arbitrary value which uniquely identifies the sensor |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2147483647 |
|
deviceSensorTrapEnabled |
1.3.6.1.4.1.3417.2.1.1.1.1.1.2 |
This variable controls generation of
deviceSensorTrap for this sensor.
When this variable is true(1), generation of
deviceSensorTrap is enabled. When this variable
is false(2), generation of deviceSensorTrap is
disabled. The default start-up value is true(1). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
deviceSensorUnits |
1.3.6.1.4.1.3417.2.1.1.1.1.1.3 |
This variable indicates the type of data
reported by the deviceSensorValue.
This variable is set by the agent at start-up
and the value does not change during operation. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SensorUnits |
|
|
deviceSensorScale |
1.3.6.1.4.1.3417.2.1.1.1.1.1.4 |
Power of 10 to apply to the value
reported by the deviceSensorValue.
This variable is set by the agent at start-up
and the value does not change during operation. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
ExpBase10 |
|
|
deviceSensorValue |
1.3.6.1.4.1.3417.2.1.1.1.1.1.5 |
This variable reports the most recent measurement
seen by the sensor. To correctly display or interpret
this variable's value, you must also know
deviceSensorUnits. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SensorValue |
|
|
deviceSensorCode |
1.3.6.1.4.1.3417.2.1.1.1.1.1.6 |
This variable reports how to interpret
deviceSensorValue for the sensor. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SensorCode |
|
|
deviceSensorStatus |
1.3.6.1.4.1.3417.2.1.1.1.1.1.7 |
This variable indicates the present operational
status of the sensor. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SensorStatus |
|
|
deviceSensorTimeStamp |
1.3.6.1.4.1.3417.2.1.1.1.1.1.8 |
This variable indicates the age of the value
reported by deviceSensorValue. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeStamp |
|
|
deviceSensorTrap |
1.3.6.1.4.1.3417.2.1.2.0.1 |
The sensor value warrants a notification. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|