DGS-6600-SYSTEM-INFO-MIB
File:
DGS-6600-SYSTEM-INFO-MIB.mib (7706 bytes)
Imported modules
Imported symbols
Defined Types
SystemDRAMutilizationEntry |
|
SEQUENCE |
|
|
|
|
systemDRAMutilizationUnitID |
INTEGER |
|
|
systemDRAMutilizationTotalDRAM |
INTEGER |
|
|
systemDRAMutilizationUsedDRAM |
INTEGER |
|
|
systemDRAMutilization |
INTEGER |
|
SystemFLASHutilizationEntry |
|
SEQUENCE |
|
|
|
|
systemFLASHutilizationUnitID |
INTEGER |
|
|
systemFLASHutilizationTotalFLASH |
INTEGER |
|
|
systemFLASHutilizationUsedFLASH |
INTEGER |
|
|
systemFLASHutilization |
INTEGER |
|
Defined Values
dgs6600SystemInfoMIB |
1.3.6.1.4.1.171.10.120.100.1.1 |
The Structure of chassis system informatiom for enterprise. |
MODULE-IDENTITY |
|
|
|
systemCPUutilizationIn5sec |
1.3.6.1.4.1.171.10.120.100.1.1.1.1.1 |
The time scale is set at 5 second intervals.
The value will be between 0%(idle) and 100%(very busy). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
systemCPUutilizationIn1min |
1.3.6.1.4.1.171.10.120.100.1.1.1.1.2 |
The time scale is set at 1 minute intervals.
The value will be between 0%(idle) and 100%(very busy). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
systemCPUutilizationIn5min |
1.3.6.1.4.1.171.10.120.100.1.1.1.1.3 |
The time scale is set at 5 minute intervals.
The value will be between 0%(idle) and 100%(very busy). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
systemDRAMutilizationEntry |
1.3.6.1.4.1.171.10.120.100.1.1.1.2.1 |
A list of information about DRAM memory. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SystemDRAMutilizationEntry |
|
|
systemDRAMutilizationUnitID |
1.3.6.1.4.1.171.10.120.100.1.1.1.2.1.1 |
Specifies the unit ID.
If the ID equals to zero, it means the current device. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..8 |
|
systemDRAMutilizationTotalDRAM |
1.3.6.1.4.1.171.10.120.100.1.1.1.2.1.2 |
The size of Total DRAM Memory. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
systemDRAMutilizationUsedDRAM |
1.3.6.1.4.1.171.10.120.100.1.1.1.2.1.3 |
The size of used DRAM memory. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
systemDRAMutilization |
1.3.6.1.4.1.171.10.120.100.1.1.1.2.1.4 |
The percentage of used DRAM memory of the total DRAM memory available.
The value will be between 0%(idle) and 100%(very busy). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
systemFLASHutilizationEntry |
1.3.6.1.4.1.171.10.120.100.1.1.1.3.1 |
A list of information about FLASH memory. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SystemFLASHutilizationEntry |
|
|
systemFLASHutilizationUnitID |
1.3.6.1.4.1.171.10.120.100.1.1.1.3.1.1 |
Specifies the unit ID.
If the ID equals to zero, it means the current device. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..8 |
|
systemFLASHutilizationTotalFLASH |
1.3.6.1.4.1.171.10.120.100.1.1.1.3.1.2 |
The size of the total FLASH memory. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
systemFLASHutilizationUsedFLASH |
1.3.6.1.4.1.171.10.120.100.1.1.1.3.1.3 |
The size of the used FLASH memory. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
systemFLASHutilization |
1.3.6.1.4.1.171.10.120.100.1.1.1.3.1.4 |
The percentage of used FLASH memory in total FLASH memory.
The value will be between 0%(idle) and 100%(very busy). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|