Juniper-FRAME-RELAY-MIB

File: Juniper-FRAME-RELAY-MIB.mib (67455 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB FRAME-RELAY-DTE-MIB Juniper-MIBs
Juniper-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter32 TimeTicks TEXTUAL-CONVENTION
RowStatus TimeStamp MODULE-COMPLIANCE
OBJECT-GROUP InterfaceIndex InterfaceIndexOrZero
DLCI juniMibs JuniNextIfIndex

Defined Types

JuniFrMlFrBundleName  
MLFR Bundle name. The bundle name is a characteristic of a MLFR frame relay interface. Represents textual information taken from the NVT ASCII graphics character set (codes 32 through 126).
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..32)  

JuniFrDlcmiEntry  
SEQUENCE    
  juniFrDlcmiIfIndex InterfaceIndex
  juniFrDlcmiState INTEGER
  juniFrDlcmiAddress INTEGER
  juniFrDlcmiAddressLen INTEGER
  juniFrDlcmiPollingInterval Integer32
  juniFrDlcmiFullEnquiryInterval Integer32
  juniFrDlcmiErrorThreshold Integer32
  juniFrDlcmiMonitoredEvents Integer32
  juniFrDlcmiMaxSupportedVCs DLCI
  juniFrDlcmiMulticast INTEGER
  juniFrDlcmiStatus INTEGER
  juniFrDlcmiRowStatus RowStatus
  juniFrDlcmiLowerIfIndex InterfaceIndexOrZero
  juniFrDlcmiRole INTEGER
  juniFrDlcmiDcePollingInterval Integer32
  juniFrDlcmiDceErrorThreshold Integer32
  juniFrDlcmiDceMonitoredEvents Integer32
  juniFrDlcmiMultilinkFrBundleName JuniFrMlFrBundleName

JuniFrDlcmiStatsEntry  
SEQUENCE    
  juniFrDlcmiStatsDteEnquiries Counter32
  juniFrDlcmiStatsDteFullEnquiries Counter32
  juniFrDlcmiStatsDteEnquiryResponses Counter32
  juniFrDlcmiStatsDteFullEnquiryResponses Counter32
  juniFrDlcmiStatsDteAsyncUpdates Counter32
  juniFrDlcmiStatsDteUnknownRxMessages Counter32
  juniFrDlcmiStatsDteLossOfSequences Counter32
  juniFrDlcmiStatsDteNoResponseTimeouts Counter32
  juniFrDlcmiStatsDceEnquiries Counter32
  juniFrDlcmiStatsDceFullEnquiries Counter32
  juniFrDlcmiStatsDceEnquiryResponses Counter32
  juniFrDlcmiStatsDceFullEnquiryResponses Counter32
  juniFrDlcmiStatsDceAsyncUpdates Counter32
  juniFrDlcmiStatsDceUnknownRxMessages Counter32
  juniFrDlcmiStatsDceLossOfSequences Counter32
  juniFrDlcmiStatsDceNoResponseTimeouts Counter32
  juniFrDlcmiStatsDiscontinuityTime TimeTicks

JuniFrCircuitEntry  
SEQUENCE    
  juniFrCircuitIfIndex InterfaceIndex
  juniFrCircuitDlci DLCI
  juniFrCircuitState INTEGER
  juniFrCircuitReceivedFECNs Counter32
  juniFrCircuitReceivedBECNs Counter32
  juniFrCircuitSentFrames Counter32
  juniFrCircuitSentOctets Counter32
  juniFrCircuitReceivedFrames Counter32
  juniFrCircuitReceivedOctets Counter32
  juniFrCircuitCreationTime TimeStamp
  juniFrCircuitLastTimeChange TimeStamp
  juniFrCircuitCommittedBurst Integer32
  juniFrCircuitExcessBurst Integer32
  juniFrCircuitThroughput Integer32
  juniFrCircuitMulticast INTEGER
  juniFrCircuitType INTEGER
  juniFrCircuitDiscards Counter32
  juniFrCircuitReceivedDEs Counter32
  juniFrCircuitSentDEs Counter32
  juniFrCircuitLogicalIfIndex InterfaceIndex
  juniFrCircuitRowStatus RowStatus
  juniFrCircuitSentFECNs Counter32
  juniFrCircuitSentBECNs Counter32

JuniFrSubIfEntry  
SEQUENCE    
  juniFrSubIfIndex InterfaceIndex
  juniFrSubIfRowStatus RowStatus
  juniFrSubIfLowerIfIndex InterfaceIndexOrZero
  juniFrSubIfId Integer32

JuniFrSubIfCktEntry  
SEQUENCE    
  juniFrSubIfCktDlci DLCI
  juniFrSubIfCktRowStatus RowStatus

JuniFrMlFrBundleEntry  
SEQUENCE    
  juniFrMlFrBundleName JuniFrMlFrBundleName
  juniFrMlFrBundleRowStatus RowStatus

JuniFrMlFrLinkConfigEntry  
SEQUENCE    
  juniFrMlFrLinkConfigIfIndex InterfaceIndex
  juniFrMlFrLinkConfigLowerIfIndex InterfaceIndexOrZero
  juniFrMlFrLinkConfigRowStatus RowStatus

JuniFrMlFrMajorConfigEntry  
SEQUENCE    
  juniFrMlFrMajorConfigIfIndex InterfaceIndex
  juniFrMlFrMajorConfigLowerIfIndex InterfaceIndex
  juniFrMlFrMajorBundleName JuniFrMlFrBundleName
  juniFrMlFrMajorRowStatus RowStatus

JuniFrMlFrLinkBindEntry  
SEQUENCE    
  juniFrMlFrBindMajorIfIndex InterfaceIndex
  juniFrMlFrBindLinkIfIndex InterfaceIndex
  juniFrMlFrBindRowStatus RowStatus

Defined Values

juniFrameRelayMIB 1.3.6.1.4.1.4874.2.2.10
The Frame Relay MIB for the Juniper Networks enterprise.
MODULE-IDENTITY    

juniFrObjects 1.3.6.1.4.1.4874.2.2.10.1
OBJECT IDENTIFIER    

juniFrIfLayer 1.3.6.1.4.1.4874.2.2.10.1.1
OBJECT IDENTIFIER    

juniFrSubIfLayer 1.3.6.1.4.1.4874.2.2.10.1.2
OBJECT IDENTIFIER    

juniFrMlFr 1.3.6.1.4.1.4874.2.2.10.1.3
OBJECT IDENTIFIER    

juniFrNextIfIndex 1.3.6.1.4.1.4874.2.2.10.1.1.1
Coordinate ifIndex value allocation for entries in juniFrDlcmiTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniFrDlcmiTable 1.3.6.1.4.1.4874.2.2.10.1.1.2
The Parameters for the Data Link Connection Management Interface for the frame relay service on this interface. This table represents a superset of functionality specified in the FRAME-RELAY-DTE-MIB. In particular, it adds attributes that permit the interface to operate as a network-side (DCE) interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrDlcmiEntry

juniFrDlcmiEntry 1.3.6.1.4.1.4874.2.2.10.1.1.2.1
The Parameters for a particular Data Link Connection Management Interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable, and juniFrDlcmiStatsTable. Creating/deleting user-side (DTE) entries in this table also causes coresponding entries to be created/deleted in FRAME-RELAY-DTE-MIB.frDlcmiTable. The organization and definitions of objects in this table are intentionally aligned closely to those in FRAME-RELAY-DTE-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrDlcmiEntry  

juniFrDlcmiIfIndex 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.1
The ifIndex value of the corresponding ifEntry.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

juniFrDlcmiState 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.2
This variable states which Data Link Connection Management scheme is active (and by implication, what DLCI it uses) on the Frame Relay interface.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noLmiConfigured(1), lmiRev1(2), ansiT1617D(3), ansiT1617B(4), itut933A(5), ansiT1617D1994(6)  

juniFrDlcmiAddress 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.3
This variable states which address format is in use on the Frame Relay interface.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER q921(1), q922March90(2), q922November90(3), q922(4)  

juniFrDlcmiAddressLen 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.4
This variable states the address length in octets. In the case of Q922 format, the length indicates the entire length of the address including the control portion.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER twoOctets(2), threeOctets(3), fourOctets(4)  

juniFrDlcmiPollingInterval 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.5
This is the number of seconds between successive status enquiry messages sent by the DTE. Pertains to DTE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DTE or NNI.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 5..30  

juniFrDlcmiFullEnquiryInterval 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.6
Number of status enquiry intervals that pass before issuance of a full status enquiry message. Pertains to DTE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DTE or NNI.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..255  

juniFrDlcmiErrorThreshold 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.7
The minimum number of errors that must be observed within the number of events specified by juniFrDlcmiMonitoredEvents, to declare the interface down. 'error' is lack of receipt of a Status, in response to an issued Status Enquiry, within the Polling Interval (T391). Pertains to DTE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DTE or NNI.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..10  

juniFrDlcmiMonitoredEvents 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.8
The number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down. 'status polling interval' is specified by juniFrDlcmiPollingInterval. Pertains to DTE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DTE or NNI.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..10  

juniFrDlcmiMaxSupportedVCs 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.9
The maximum number of Virtual Circuits allowed for this interface. Usually dictated by the Frame Relay network. In response to a SET, if a value less than zero or higher than the agent's maximal capability is configured, the agent should respond badValue.
Status: current Access: read-create
OBJECT-TYPE    
  DLCI  

juniFrDlcmiMulticast 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.10
This indicates whether the Frame Relay interface is using a multicast service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nonBroadcast(1), broadcast(2)  

juniFrDlcmiStatus 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.11
This indicates the status of the Frame Relay interface as determined by the performance of the DLCMI. If no DLCMI is running, the Frame Relay interface will stay in the running state indefinitely.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER running(1), fault(2), initializing(3)  

juniFrDlcmiRowStatus 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.12
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniFrDlcmiRowStatus juniFrDlcmiState juniFrDlcmiMaxSupportedVCs juniFrDlcmiLowerIfIndex juniFrDlcmiRole juniFrDlcmiMultilinkFrBundleName (Only for multilink frame relay) In addition, when creating an entry the following conditions must hold: A value for juniFrDlcmiIndex must have been determined previously, by reading juniFrNextIfIndex. The interface identified by juniFrDlcmiLowerIfIndex must exist, and must be an interface type that permits layering of Frame Relay above it. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table. If juniFrDlcmiRole is dte(0), a corresponding entry is created/deleted in frDlcmiTable.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrDlcmiLowerIfIndex 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.13
The ifIndex of an interface over which this Frame Relay interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation. In case of multilink frame relay support, it will be multilink frame relay interface's ifIndex.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniFrDlcmiRole 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.14
Specifies the role this interface assumes with respect to the remote end. When acting as a DTE, the following objects are not relevant: juniFrDlcmiDcePollingInterval juniFrDlcmiDceErrorThreshold juniFrDlcmiDceMonitoredEvents When acting as a DCE, the following objects are not relevant: juniFrDlcmiPollingInterval juniFrDlcmiFullEnquiryInterval juniFrDlcmiErrorThreshold juniFrDlcmiMonitoredEvents
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER dte(0), dce(1), nni(2)  

juniFrDlcmiDcePollingInterval 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.15
The number of seconds within which a DCE expects to receive a Status Enquiry from the DTE. This value corresponds to the T392 timer. Pertains to DCE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DCE or NNI.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 5..30  

juniFrDlcmiDceErrorThreshold 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.16
The minimum number of errors that must be observed within the number of events specified by juniFrDlcmiDceMonitoredEvents, to declare the interface down. 'error' is lack of receipt of a Status Enquiry within the interval specified by juniFrDlcmiDcePollingInterval (T392). Pertains to DCE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DCE or NNI.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..10  

juniFrDlcmiDceMonitoredEvents 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.17
The number of DCE polling intervals over which accumulated errors are counted against the threshold specified in juniFrDlcmiDceErrorThreshold. If, within this number of events, the number of errors equals or exceeds the threshold, the interface is declared down. The 'DCE polling interval' is specified by juniFrDlcmiDcePollingInterval. Pertains to DCE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DCE or NNI.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..10  

juniFrDlcmiMultilinkFrBundleName 1.3.6.1.4.1.4874.2.2.10.1.1.2.1.18
This represents multilink frame relay bundle name. This object must be configured to associate the bundle name to the frame relay major interface to support the multilink frame relay encapsulation. For non-multilink frame relay, bundle name configuration is not valid and will be ignored.
Status: current Access: read-create
OBJECT-TYPE    
  JuniFrMlFrBundleName  

juniFrDlcmiStatsTable 1.3.6.1.4.1.4874.2.2.10.1.1.3
The statistics for the Data Link Connection Management Interface for the frame relay service on this interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrDlcmiStatsEntry

juniFrDlcmiStatsEntry 1.3.6.1.4.1.4874.2.2.10.1.1.3.1
The statistics for a particular Data Link Connection Management Interface. Statistics are not relevant while the juniFrDlcmiState has the value 'noLmiConfigured'. The DTE statistics are relevant when the corresponding juniFrDlcmiRole is DTE. The DTE statistics are relevant when the corresponding juniFrDlcmiRole is DCE.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrDlcmiStatsEntry  

juniFrDlcmiStatsDteEnquiries 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.1
Number of Status Enquiries sent (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDteFullEnquiries 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.2
Number of Full Enquiries sent (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDteEnquiryResponses 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.3
Number of Status Enquiry responses received (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDteFullEnquiryResponses 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.4
Number of Full Enquiry responses received (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDteAsyncUpdates 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.5
Number of Asynchronous Updates received (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDteUnknownRxMessages 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.6
Number of unknown messages received (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDteLossOfSequences 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.7
Number of times a discontinuity in sequence numbering of received messages was detected (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDteNoResponseTimeouts 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.8
Number of timer expirations awaiting a Status message (as DTE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceEnquiries 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.9
Number of Status Enquiries received (as DCE.)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceFullEnquiries 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.10
Number of Full Enquiries received (as DCE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceEnquiryResponses 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.11
Number of Status Enquiry responses sent (as DCE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceFullEnquiryResponses 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.12
Number of Full Enquiry responses sent (as DCE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceAsyncUpdates 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.13
Number of Asynchronous Updates sent (as DCE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceUnknownRxMessages 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.14
Number of unknown messages received (as DCE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceLossOfSequences 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.15
Number of times a discontinuity in sequence numbering of received messages was detected (as DCE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDceNoResponseTimeouts 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.16
Number of timer expirations awaiting a Status Enquiry (as DCE).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrDlcmiStatsDiscontinuityTime 1.3.6.1.4.1.4874.2.2.10.1.1.3.1.17
Value of sysUpTime at the most recent event that caused a discontinuity in the monotonic operation of any of the counters in this entry. Such disruption might be caused by: Hardware insertion/removal. Reconfiguration of juniFrDlcmiState. Reconfiguration of juniFrDlcmiRole. Conclusions can be drawn from successive polls of an entry's counters only if the value of this object, simultaneously retrieved in those polls, remains unchanged.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

juniFrCircuitTable 1.3.6.1.4.1.4874.2.2.10.1.1.4
A table containing information about specific Data Link Connections (DLC) or virtual circuits. This table mirrors the structure of FRAME-RELAY-DTE-MIB.frCircuitTable, for the purpose of enumerating circuits on both DTE and DCE Frame Relay interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrCircuitEntry

juniFrCircuitEntry 1.3.6.1.4.1.4874.2.2.10.1.1.4.1
The information regarding a single Data Link Connection. Discontinuities in the counters contained in this table are indicated by the value in juniFrCircuitCreationTime.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrCircuitEntry  

juniFrCircuitIfIndex 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.1
The ifIndex Value of the ifEntry this virtual circuit is layered onto.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniFrCircuitDlci 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.2
The Data Link Connection Identifier for this virtual circuit.
Status: current Access: not-accessible
OBJECT-TYPE    
  DLCI  

juniFrCircuitState 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.3
Indicates whether the particular virtual circuit is operational. In the absence of a Data Link Connection Management Interface, virtual circuit entries (rows) may be created by setting virtual circuit state to 'active', or deleted by changing Circuit state to 'invalid'. Whether or not the row actually disappears is left to the implementation, so this object may actually read as 'invalid' for some arbitrary length of time. It is also legal to set the state of a virtual circuit to 'inactive' to temporarily disable a given circuit. The use of 'invalid' is deprecated in this SNMP Version 2 MIB, in favor of juniFrCircuitRowStatus.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER invalid(1), active(2), inactive(3)  

juniFrCircuitReceivedFECNs 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.4
Number of frames received from the network indicating forward congestion since the virtual circuit was created. This occurs when the remote DTE sets the FECN flag, or when a switch in the network enqueues the frame to a trunk whose transmission queue is congested.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitReceivedBECNs 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.5
Number of frames received from the network indicating backward congestion since the virtual circuit was created. This occurs when the remote DTE sets the BECN flag, or when a switch in the network receives the frame from a trunk whose transmission queue is congested.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitSentFrames 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.6
The number of frames sent from this virtual circuit since it was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitSentOctets 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.7
The number of octets sent from this virtual circuit since it was created. Octets counted are the full frame relay header and the payload, but do not include the flag characters or CRC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitReceivedFrames 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.8
Number of frames received over this virtual circuit since it was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitReceivedOctets 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.9
Number of octets received over this virtual circuit since it was created. Octets counted include the full frame relay header, but do not include the flag characters or the CRC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitCreationTime 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.10
The value of sysUpTime when the virtual circuit was created, whether by the Data Link Connection Management Interface or by a SetRequest.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

juniFrCircuitLastTimeChange 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.11
The value of sysUpTime when last there was a change in the virtual circuit state
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

juniFrCircuitCommittedBurst 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.12
This variable indicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval. A value of zero (the default) indicates no commitment.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniFrCircuitExcessBurst 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.13
This variable indicates the maximum amount of uncommitted data bits that the network will attempt to deliver over the measurement interval. By default, if not configured when creating the entry, the Excess Information Burst Size is set to the value of ifSpeed.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniFrCircuitThroughput 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.14
Throughput is the average number of 'Frame Relay Information Field' bits transferred per second across a user network interface in one direction, measured over the measurement interval. If the configured committed burst rate and throughput are both non-zero, the measurement interval, T, is T = juniFrCircuitCommittedBurst / juniFrCircuitThroughput. If the configured committed burst rate and throughput are both zero, the measurement interval, T, is T = juniFrCircuitExcessBurst / ifSpeed A value of zero (the default) for throughput indicates no commitment.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniFrCircuitMulticast 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.15
This indicates whether this VC is used as a unicast VC (i.e. not multicast) or the type of multicast service subscribed to.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER unicast(1), oneWay(2), twoWay(3), nWay(4)  

juniFrCircuitType 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.16
Indication of whether the VC was manually created (static), or dynamically created (dynamic) via the data link control management interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER static(1), dynamic(2)  

juniFrCircuitDiscards 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.17
The number of inbound frames dropped because of format errors, or because the VC is inactive.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitReceivedDEs 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.18
Number of frames received from the network indicating that they were eligible for discard since the virtual circuit was created. This occurs when the remote DTE sets the DE flag, or when in remote DTE's switch detects that the frame was received as Excess Burst data.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitSentDEs 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.19
Number of frames sent to the network indicating that they were eligible for discard since the virtual circuit was created. This occurs when the local DTE sets the DE flag, indicating that during Network congestion situations those frames should be discarded in preference of other frames sent without the DE bit set.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitLogicalIfIndex 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.20
Normally the same value as frDlcmiIfIndex, but different when an implementation associates a virtual ifEntry with a DLC or set of DLCs in order to associate higher layer objects such as the ipAddrEntry with a subset of the virtual circuits on a Frame Relay interface. The type of such ifEntries is defined by the higher layer object; for example, if PPP/Frame Relay is implemented, the ifType of this ifEntry would be PPP. If it is not so defined, as would be the case with an ipAddrEntry, it should be of type Other.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndex  

juniFrCircuitRowStatus 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.21
This object is used to create a new row or modify or destroy an existing row in the manner described in the definition of the RowStatus textual convention. Writable objects in the table may be written in any RowStatus state.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrCircuitSentFECNs 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.22
Number of frames sent to the network indicating forward congestion since the virtual circuit was created. This occurs when the remote DTE sets the FECN flag, or when a switch in the network enqueues the frame to a trunk whose transmission queue is congested.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrCircuitSentBECNs 1.3.6.1.4.1.4874.2.2.10.1.1.4.1.23
Number of frames sent to the network indicating backward congestion since the virtual circuit was created. This occurs when the remote DTE sets the BECN flag, or when a switch in the network receives the frame from a trunk whose transmission queue is congested.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniFrSubIfNextIfIndex 1.3.6.1.4.1.4874.2.2.10.1.2.1
Coordinate ifIndex value allocation for entries in juniFrSubIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniFrSubIfTable 1.3.6.1.4.1.4874.2.2.10.1.2.2
This table contains entries for Frame Relay Subinterfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrSubIfEntry

juniFrSubIfEntry 1.3.6.1.4.1.4874.2.2.10.1.2.2.1
Each entry describes the characteristics of a Frame Relay Subinterface. Creating/deleting entries in this table causes corresponding entries for be created /deleted in ifTable/ifXTable/juniIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrSubIfEntry  

juniFrSubIfIndex 1.3.6.1.4.1.4874.2.2.10.1.2.2.1.1
The ifIndex of the Frame Relay Subinterface. When creating entries in this table, suitable values for this object are determined by reading juniFrSubNextIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniFrSubIfRowStatus 1.3.6.1.4.1.4874.2.2.10.1.2.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniFrSubIfRowStatus juniFrSubIfLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for juniFrSubIfIndex must have been determined previously, by reading juniFrSubIfNextIfIndex. The interface identified by juniFrSubIfLowerIfIndex must exist, and must be a Frame Relay interface. A positive value configured for juniFrSubIfId must not already be assigned to another subinterface layered onto the same underlying Frame Relay interface. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrSubIfLowerIfIndex 1.3.6.1.4.1.4874.2.2.10.1.2.2.1.3
The ifIndex of a Frame Relay interface over which this Frame Relay Subinterface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniFrSubIfId 1.3.6.1.4.1.4874.2.2.10.1.2.2.1.4
An integer identifier for the Frame Relay subinterface, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among subinterfaces configured on the same underlying Frame Relay interface. If this object is not configured, or is configured with a value of -1, a nonzero value will be allocated internally and can be retrieved from this object after table entry creation has succeeded. A value of zero for this object is reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

juniFrSubIfCktTable 1.3.6.1.4.1.4874.2.2.10.1.2.3
This table contains entries for Frame Relay circuits configured on Frame Relay Subinterfaces present in the system. An implementation may constrain the number of circuits permitted to be configured per Frame Relay Subinterface; in particular, an implementation may restrict each Frame Relay Subinterface to have a single circuit. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrSubIfCktEntry

juniFrSubIfCktEntry 1.3.6.1.4.1.4874.2.2.10.1.2.3.1
Each entry describes the characteristics of a Frame Relay Subinterface circuit.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrSubIfCktEntry  

juniFrSubIfCktDlci 1.3.6.1.4.1.4874.2.2.10.1.2.3.1.1
The DLCI of the Frame Relay circuit used by this subinterface.
Status: current Access: not-accessible
OBJECT-TYPE    
  DLCI  

juniFrSubIfCktRowStatus 1.3.6.1.4.1.4874.2.2.10.1.2.3.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniFrSubIfCktRowStatus
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrMlFrBundleTable 1.3.6.1.4.1.4874.2.2.10.1.3.1
This table contains entries for MLFR bundles present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrMlFrBundleEntry

juniFrMlFrBundleEntry 1.3.6.1.4.1.4874.2.2.10.1.3.1.1
Each entry describes the characteristics of a Multilink bundle.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrMlFrBundleEntry  

juniFrMlFrBundleName 1.3.6.1.4.1.4874.2.2.10.1.3.1.1.1
The administrative name of the multilink bundle associated with this Frame Relay major interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrMlFrBundleName  

juniFrMlFrBundleRowStatus 1.3.6.1.4.1.4874.2.2.10.1.3.1.1.2
The rowStatus for this entry. The following sets are supported: createAndGo(4), destroy(6) The following values can be read from this object: active(1)
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrMlFrNextLinkIfIndex 1.3.6.1.4.1.4874.2.2.10.1.3.2
Coordinate ifIndex value allocation for entries in juniFrMlFrLinkConfigTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniFrMlFrLinkConfigTable 1.3.6.1.4.1.4874.2.2.10.1.3.3
This table contains entries for FR link interfaces present in the system to be added to the multilink bundles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrMlFrLinkConfigEntry

juniFrMlFrLinkConfigEntry 1.3.6.1.4.1.4874.2.2.10.1.3.3.1
Each entry describes the characteristics of FR link interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrMlFrLinkConfigEntry  

juniFrMlFrLinkConfigIfIndex 1.3.6.1.4.1.4874.2.2.10.1.3.3.1.1
The ifIndex of the FR link interface. When creating entries in this table, suitable values for this object are determined by reading juniFrMlFrNextLinkIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniFrMlFrLinkConfigLowerIfIndex 1.3.6.1.4.1.4874.2.2.10.1.3.3.1.2
The ifIndex of an interface over which this FR link interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a non-zero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniFrMlFrLinkConfigRowStatus 1.3.6.1.4.1.4874.2.2.10.1.3.3.1.3
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniFrMlFrLinkConfigRowStatus juniFrMlFrLinkConfigLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for juniFrMlFrLinkConfigIfIndex must have been determined previously, by reading juniFrMlFrNextIfIndex. The interface identified by juniFrMlFrLinkConfigLowerIfIndex must exist. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrMlFrMajorConfigTable 1.3.6.1.4.1.4874.2.2.10.1.3.4
This table contains entries for FR major interfaces present in the system which are associated with multilink bundles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrMlFrMajorConfigEntry

juniFrMlFrMajorConfigEntry 1.3.6.1.4.1.4874.2.2.10.1.3.4.1
Each entry describes the characteristics of FR major interface which have association with the MLFR bundles. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrMlFrMajorConfigEntry  

juniFrMlFrMajorConfigIfIndex 1.3.6.1.4.1.4874.2.2.10.1.3.4.1.1
The ifIndex of the FR Major interface. When creating entries in this table, suitable values for this object are determined by reading already created FR Major interface values. Each multilink bundle will be associated with one FR major interface. This association will be done at the creation of FR major interface (juniFrDlcmiTable) specifying its lower interfce binding as FR link ifIndex(juniFrMlFrLinkConfigTable) and the multilink bundle name.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniFrMlFrMajorConfigLowerIfIndex 1.3.6.1.4.1.4874.2.2.10.1.3.4.1.2
The ifIndex of a FR link interface over which this FR Major interface is to be layered. On sets, the value of this object must equal on of the previously created FR link interfaces created in the juniFrMlFrLinkConfigTable. On gets, the value of this object is the lexicographically least FR link interface in a potential bundle of FR link interfaces.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndex  

juniFrMlFrMajorBundleName 1.3.6.1.4.1.4874.2.2.10.1.3.4.1.3
The MLFR bundle name administratively assigned.
Status: current Access: read-create
OBJECT-TYPE    
  JuniFrMlFrBundleName  

juniFrMlFrMajorRowStatus 1.3.6.1.4.1.4874.2.2.10.1.3.4.1.4
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniFrMlFrMajorConfigLowerIfIndex juniFrMlFrMajorBundleName juniFrMlFrMajorConfigRowStatus In addition, when creating an entry the following conditions must hold: The interface identified by juniFrMlFrMajorConfigIndex must exist by a creation request to the juniFrDlcmiTable. The interface identified by juniFrMlFrMajorConfigLowerIfIndex must exist by a creation request to the juniFrMlFrLinkConfigTable. The bundleName specified in juniFrMlFrMajorBundleName must have been created first in the juniFrMlFrBundleTable. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrMlFrLinkBindTable 1.3.6.1.4.1.4874.2.2.10.1.3.5
This table contains entries for FR Link interfaces to FR major interfaces bindings associated with multilink bundles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniFrMlFrLinkBindEntry

juniFrMlFrLinkBindEntry 1.3.6.1.4.1.4874.2.2.10.1.3.5.1
Each entry describes the FR link interface to FR major interface bindingsi associated with multilink bundles.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniFrMlFrLinkBindEntry  

juniFrMlFrBindMajorIfIndex 1.3.6.1.4.1.4874.2.2.10.1.3.5.1.1
The ifIndex of the FR major interface associated with multilink.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniFrMlFrBindLinkIfIndex 1.3.6.1.4.1.4874.2.2.10.1.3.5.1.2
The ifIndex of a FR link interface bound by the FR major interface defined by juniFrMlFrBindMajorIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniFrMlFrBindRowStatus 1.3.6.1.4.1.4874.2.2.10.1.3.5.1.3
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniFrMlFrBindRowStatus In addition, when creating an entry the following conditions must hold: The interfaces identified by juniFrMlFrBindNetworkIfIndex and juniFrMlFrBindLinkIfIndex must be created in the juniFrMlFrMajorConfigTable and juniFrMlFrLinkConfigTable respectively. A MLFR bundle must be associated with the juniFrMlFrMajorIfIndex and exist in the juniFrMibFrBundleTable. A corresponding entry in ifStackTable is created/destroyed as a result of creating/destroying an entry in this table. Note: This table is read-only table for now. To add links to bundle make use of juniFrMlFrMajorConfigTable.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniFrConformance 1.3.6.1.4.1.4874.2.2.10.4
OBJECT IDENTIFIER    

juniFrCompliances 1.3.6.1.4.1.4874.2.2.10.4.1
OBJECT IDENTIFIER    

juniFrGroups 1.3.6.1.4.1.4874.2.2.10.4.2
OBJECT IDENTIFIER    

juniFrCompliance 1.3.6.1.4.1.4874.2.2.10.4.1.1
Obsolete compliance statement for entities that implement the Juniper Frame Relay MIB. This statement became obsolete when multi-link frame relay support was added.
Status: obsolete Access: read-create
MODULE-COMPLIANCE    

juniFrCompliance2 1.3.6.1.4.1.4874.2.2.10.4.1.2
The compliance statement for entities that implement the Juniper Frame Relay MIB.
Status: current Access: read-create
MODULE-COMPLIANCE    

juniFrGroup 1.3.6.1.4.1.4874.2.2.10.4.2.1
Obsolete collection of objects providing management of Frame Relay interfaces in a Juniper product. This group became obsolete when multi-link frame relay support was added.
Status: obsolete Access: read-create
OBJECT-GROUP    

juniFrSubIfGroup 1.3.6.1.4.1.4874.2.2.10.4.2.2
A collection of objects providing management of Frame Relay subinterfaces in a Juniper product.
Status: current Access: read-create
OBJECT-GROUP    

juniFrGroup2 1.3.6.1.4.1.4874.2.2.10.4.2.3
A collection of objects providing management of Frame Relay interfaces in a Juniper product.
Status: current Access: read-create
OBJECT-GROUP    

juniFrMlFrGroup 1.3.6.1.4.1.4874.2.2.10.4.2.4
A collection of objects providing management of Multilink Frame Relay in a Juniper product.
Status: current Access: read-create
OBJECT-GROUP