SIAE-PMG828-MIB
File:
SIAE-PMG828-MIB.mib (20381 bytes)
Imported modules
Imported symbols
Defined Types
PmG828TpMaintRecord |
|
SEQUENCE |
|
|
|
|
pmG828TpMaintCounterClear |
INTEGER |
|
|
pmG828TpMaintAlarmClear |
INTEGER |
|
Defined Values
pmG828 |
1.3.6.1.4.1.3373.1103.11 |
Perforfamce Monitoring according to ITU-T G.829 for Radio Link
and E1 Tributaries
|
MODULE-IDENTITY |
|
|
|
pmG828MibVersion |
1.3.6.1.4.1.3373.1103.11.1 |
Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
pmG828CounterTable |
1.3.6.1.4.1.3373.1103.11.2 |
Table with PmG828 records: one record for 1+0 configuration and two
record for 1+1 configuration. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PmG828CounterRecord |
|
pmG828TPointId |
1.3.6.1.4.1.3373.1103.11.2.1.1 |
This object identifies the Termination Point. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828CounterBlockId |
1.3.6.1.4.1.3373.1103.11.2.1.2 |
This object identifies the counters block and the counter type
according to the following code:
1 Current Daily counters
2 Daily counters (Day before counters)
3 Current 15 minutes counters
4 15 minutes counters N. 1 (The most recent 15 minutes counters)
..............................................
n 15 minutes counters N. n
20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828CounterBlockType |
1.3.6.1.4.1.3373.1103.11.2.1.3 |
The type of the counter block. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
daily(1), fifteenMin(2) |
|
pmG828CounterBlockStatus |
1.3.6.1.4.1.3373.1103.11.2.1.4 |
Status of the block counter. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
meaningless(1), meaningfull(2), incomplete(3), dummy(4), lost(5), restarted(6) |
|
pmG828CounterTimeStamp |
1.3.6.1.4.1.3373.1103.11.2.1.5 |
The object is the time when the performance record is closed reported
as the second number since 1-Gen-1970. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
pmG828TpClassTable |
1.3.6.1.4.1.3373.1103.11.3 |
Table with PmG828TpClass records: one record for 1+0 configuration and
two record for 1+1 configuration. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PmG828TpClassRecord |
|
pmG828TpClassId |
1.3.6.1.4.1.3373.1103.11.3.1.1 |
This object identifies the Termination Point. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpClassStartStop |
1.3.6.1.4.1.3373.1103.11.3.1.2 |
This object is used to start and to stop the Perfomance Monitoring
counter evaluation. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
start(1), stop(2) |
|
pmG828TpClassLabel |
1.3.6.1.4.1.3373.1103.11.3.1.3 |
ASCII string used to identify the Tp class:
for example:
pmG828TpClassBranchId = 1 label = Radio 1
pmG828TpClassBranchId = 2 label = Radio 2
pmG828TpClassBranchId = 3 label = Radio(switched)
pmG828TpClassBranchId = 4 label = Trib E1 line side
pmG828TpClassBranchId = 5 label = Trib E1 radio side. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..31) |
|
pmG828TpClass15MEsAlarm |
1.3.6.1.4.1.3373.1103.11.3.1.5 |
15 minutes ES threshold cross alarm with associated severity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AlarmStatus |
|
|
pmG828TpClass15MSesAlarm |
1.3.6.1.4.1.3373.1103.11.3.1.6 |
15 minutes SES threshold cross alarm with associated severity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AlarmStatus |
|
|
pmG828TpClass15MSepAlarm |
1.3.6.1.4.1.3373.1103.11.3.1.7 |
15 minutes SEP threshold cross alarm with associated severity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AlarmStatus |
|
|
pmG828TpClass15MEsThreshold |
1.3.6.1.4.1.3373.1103.11.3.1.12 |
Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm
(zero value disables the alarm). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpClass15MSesThreshold |
1.3.6.1.4.1.3373.1103.11.3.1.13 |
Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm
(zero value disables the alarm). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpClass15MSepThreshold |
1.3.6.1.4.1.3373.1103.11.3.1.14 |
Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm
(zero value disables the alarm). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpClass24HEsThreshold |
1.3.6.1.4.1.3373.1103.11.3.1.15 |
Number of ES within one day to set pmG828TpClass24HEsAlarm
(zero value disables the alarm). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpClass24HSesThreshold |
1.3.6.1.4.1.3373.1103.11.3.1.16 |
Number of SES within one day to set pmG828TpClass24HSesAlarm
(zero value disables the alarm). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpClass24HSepThreshold |
1.3.6.1.4.1.3373.1103.11.3.1.17 |
Number of SEP within one day to set pmG828TpClass24HSepAlarm
(zero value disables the alarm). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpMaintTable |
1.3.6.1.4.1.3373.1103.11.4 |
Table with Command for maintenance of Termination Point.
Objects in this table is not persistent. An Instance of this
table is created on creation of pmG828TpClassTable |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PmG828TpMaintRecord |
|
pmG828TpMaintRecord |
1.3.6.1.4.1.3373.1103.11.4.1 |
PmG828 Termination Point Maintenance record. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PmG828TpMaintRecord |
|
|
pmG828TpMaintCounterClear |
1.3.6.1.4.1.3373.1103.11.4.1.1 |
This object is used to clear the Perfomance Monitoring counters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notActive(0), clear(1) |
|
pmG828TpMaintAlarmClear |
1.3.6.1.4.1.3373.1103.11.4.1.2 |
This object is used to clear the Perfomance Monitoring threshold cross alarms. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notActive(0), clear(1) |
|
pmG828NSesSetUAS |
1.3.6.1.4.1.3373.1103.11.5 |
Number of SES (according G.828) to set UAS. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828NSesResetUAS |
1.3.6.1.4.1.3373.1103.11.6 |
Number of seconds whitout errors (according G.828) to reset UAS. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
pmG828TpClassUASAlarmSeverityCode |
1.3.6.1.4.1.3373.1103.11.11 |
Define the severity associated to the pmG828TpClassUASAlarm and
enables/disables the trap generation on status change event. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
AlarmSeverityCode |
|
|