TELDAT-TRAP-SL-MIB
File:
TELDAT-TRAP-SL-MIB.mib (46628 bytes)
Imported modules
Imported symbols
Defined Values
slTrapsMIB |
1.3.6.1.4.1.2007.1.4.83 |
This Module Information Base file is defined for managing received
SNMP notifications generated by the SL event subsystem. |
MODULE-IDENTITY |
|
|
|
slEventObjects1 |
1.3.6.1.4.1.2007.1.4.83.1.1 |
Event SL.1
A packet buffer was not available when the interface self-test
needed one. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
sl1-interface |
1.3.6.1.4.1.2007.1.4.83.1.1.1 |
Parameter 'interface' in event SL.1 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects2 |
1.3.6.1.4.1.2007.1.4.83.1.2 |
Event SL.2
During the self-test, the interface card detected that certain signals
from modem necessary to indicate that it is present and ready to operate
were not detectable. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl2-interface |
1.3.6.1.4.1.2007.1.4.83.1.2.1 |
Parameter 'interface' in event SL.2 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects3 |
1.3.6.1.4.1.2007.1.4.83.1.3 |
Event SL.3
During self-test, an Echo Acknowledgement was not received from the
other end of the line within the timeout period. The network fails
self-test. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl3-interface |
1.3.6.1.4.1.2007.1.4.83.1.3.1 |
Parameter 'interface' in event SL.3 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects4 |
1.3.6.1.4.1.2007.1.4.83.1.4 |
Event SL.4
A bad length field or truncated packet was detected in a DECnet packet
on the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl4-actual-length |
1.3.6.1.4.1.2007.1.4.83.1.4.1 |
Parameter 'actual-length' in event SL.4 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl4-claimed-length |
1.3.6.1.4.1.2007.1.4.83.1.4.2 |
Parameter 'claimed-length' in event SL.4 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl4-interface |
1.3.6.1.4.1.2007.1.4.83.1.4.3 |
Parameter 'interface' in event SL.4 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects5 |
1.3.6.1.4.1.2007.1.4.83.1.5 |
Event SL.5
A network control packet was received with a packet type which did not
match any known opcode. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl5-opcode |
1.3.6.1.4.1.2007.1.4.83.1.5.1 |
Parameter 'opcode' in event SL.5 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl5-interface |
1.3.6.1.4.1.2007.1.4.83.1.5.2 |
Parameter 'interface' in event SL.5 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects6 |
1.3.6.1.4.1.2007.1.4.83.1.6 |
Event SL.6
A serial line packet was received with a higher level protocol which
did not match any known protocol. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl6-protocol |
1.3.6.1.4.1.2007.1.4.83.1.6.1 |
Parameter 'protocol' in event SL.6 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl6-interface |
1.3.6.1.4.1.2007.1.4.83.1.6.2 |
Parameter 'interface' in event SL.6 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects7 |
1.3.6.1.4.1.2007.1.4.83.1.7 |
Event SL.7
Self-test is being started on the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl7-interface |
1.3.6.1.4.1.2007.1.4.83.1.7.1 |
Parameter 'interface' in event SL.7 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects8 |
1.3.6.1.4.1.2007.1.4.83.1.8 |
Event SL.8
An echo request is being sent on the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl8-interface |
1.3.6.1.4.1.2007.1.4.83.1.8.1 |
Parameter 'interface' in event SL.8 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects9 |
1.3.6.1.4.1.2007.1.4.83.1.9 |
Event SL.9
A test packet has been received on the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl9-interface |
1.3.6.1.4.1.2007.1.4.83.1.9.1 |
Parameter 'interface' in event SL.9 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects10 |
1.3.6.1.4.1.2007.1.4.83.1.10 |
Event SL.10
An echo acknowledgement packet has been received on the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl10-interface |
1.3.6.1.4.1.2007.1.4.83.1.10.1 |
Parameter 'interface' in event SL.10 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects11 |
1.3.6.1.4.1.2007.1.4.83.1.11 |
Event SL.11
An echo acknowledgement packet has been received on the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl11-interface |
1.3.6.1.4.1.2007.1.4.83.1.11.1 |
Parameter 'interface' in event SL.11 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects12 |
1.3.6.1.4.1.2007.1.4.83.1.12 |
Event SL.12
A test packet used for network maintenence is being sent on
the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl12-interface |
1.3.6.1.4.1.2007.1.4.83.1.12.1 |
Parameter 'interface' in event SL.12 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects13 |
1.3.6.1.4.1.2007.1.4.83.1.13 |
Event SL.13
A Bridged packet is received on this serial line interface even though
the Spanning Tree Bridging is not enabled on this interface or STB
is disabled in the box. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl13-interface |
1.3.6.1.4.1.2007.1.4.83.1.13.1 |
Parameter 'interface' in event SL.13 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects14 |
1.3.6.1.4.1.2007.1.4.83.1.14 |
Event SL.14
Dual Serial Line Interface board firmware download has completed with
the status shown. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl14-slot-num |
1.3.6.1.4.1.2007.1.4.83.1.14.1 |
Parameter 'slot-num' in event SL.14 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl14-ld-code |
1.3.6.1.4.1.2007.1.4.83.1.14.2 |
Parameter 'ld-code' in event SL.14 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects15 |
1.3.6.1.4.1.2007.1.4.83.1.15 |
Event SL.15
Dual Serial Line Board Power-On Diagnostics status completed with the
code shown. See Power-On Diagnostics manual for encoding. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl15-slot-num |
1.3.6.1.4.1.2007.1.4.83.1.15.1 |
Parameter 'slot-num' in event SL.15 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl15-pud-stat |
1.3.6.1.4.1.2007.1.4.83.1.15.2 |
Parameter 'pud-stat' in event SL.15 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
slEventObjects16 |
1.3.6.1.4.1.2007.1.4.83.1.16 |
Event SL.16
Protocol type like Ethertype, DSAPytype or SNAPtype packet filtered.
This is due to the user supplied protocol filtering information. (STB). |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl16-protocol-type |
1.3.6.1.4.1.2007.1.4.83.1.16.1 |
Parameter 'protocol-type' in event SL.16 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl16-protocol |
1.3.6.1.4.1.2007.1.4.83.1.16.2 |
Parameter 'protocol' in event SL.16 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl16-interface |
1.3.6.1.4.1.2007.1.4.83.1.16.3 |
Parameter 'interface' in event SL.16 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects17 |
1.3.6.1.4.1.2007.1.4.83.1.17 |
Event SL.17
Packet dropped as the protocol type is enabled but packet arrived
as bridged. (STB). |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl17-protocol-type |
1.3.6.1.4.1.2007.1.4.83.1.17.1 |
Parameter 'protocol-type' in event SL.17 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl17-src-addr |
1.3.6.1.4.1.2007.1.4.83.1.17.2 |
Parameter 'src-addr' in event SL.17 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl17-interface |
1.3.6.1.4.1.2007.1.4.83.1.17.3 |
Parameter 'interface' in event SL.17 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects18 |
1.3.6.1.4.1.2007.1.4.83.1.18 |
Event SL.18
Packet dropped as the protocol filtering applies (STB). |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl18-protocol-type |
1.3.6.1.4.1.2007.1.4.83.1.18.1 |
Parameter 'protocol-type' in event SL.18 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl18-interface |
1.3.6.1.4.1.2007.1.4.83.1.18.2 |
Parameter 'interface' in event SL.18 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects19 |
1.3.6.1.4.1.2007.1.4.83.1.19 |
Event SL.19
The cable and the level converter on the interface are not compatible
with each other. The self-test will fail. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl19-cable-type |
1.3.6.1.4.1.2007.1.4.83.1.19.1 |
Parameter 'cable-type' in event SL.19 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl19-interface |
1.3.6.1.4.1.2007.1.4.83.1.19.3 |
Parameter 'interface' in event SL.19 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects20 |
1.3.6.1.4.1.2007.1.4.83.1.20 |
Event SL.20
There is an incompatibility between the mode of the cable (DCE or DTE)
and the type of clocking used. The interface will not be brought up. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl20-cable-type |
1.3.6.1.4.1.2007.1.4.83.1.20.1 |
Parameter 'cable-type' in event SL.20 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl20-interface |
1.3.6.1.4.1.2007.1.4.83.1.20.3 |
Parameter 'interface' in event SL.20 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects21 |
1.3.6.1.4.1.2007.1.4.83.1.21 |
Event SL.21
The interface failed self test because at least one of the
modem signals was off. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl21-cts |
1.3.6.1.4.1.2007.1.4.83.1.21.1 |
Parameter 'cts' in event SL.21 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl21-dsr |
1.3.6.1.4.1.2007.1.4.83.1.21.2 |
Parameter 'dsr' in event SL.21 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl21-dcd |
1.3.6.1.4.1.2007.1.4.83.1.21.3 |
Parameter 'dcd' in event SL.21 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl21-interface |
1.3.6.1.4.1.2007.1.4.83.1.21.4 |
Parameter 'interface' in event SL.21 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects22 |
1.3.6.1.4.1.2007.1.4.83.1.22 |
Event SL.22
A modem status change has occurred. The present state is described. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl22-cts |
1.3.6.1.4.1.2007.1.4.83.1.22.1 |
Parameter 'cts' in event SL.22 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl22-dsr |
1.3.6.1.4.1.2007.1.4.83.1.22.2 |
Parameter 'dsr' in event SL.22 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl22-dcd |
1.3.6.1.4.1.2007.1.4.83.1.22.3 |
Parameter 'dcd' in event SL.22 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl22-interface |
1.3.6.1.4.1.2007.1.4.83.1.22.4 |
Parameter 'interface' in event SL.22 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects23 |
1.3.6.1.4.1.2007.1.4.83.1.23 |
Event SL.23
The interface was brought down because one of the modem signals was off. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl23-cts |
1.3.6.1.4.1.2007.1.4.83.1.23.1 |
Parameter 'cts' in event SL.23 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl23-dsr |
1.3.6.1.4.1.2007.1.4.83.1.23.2 |
Parameter 'dsr' in event SL.23 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl23-dcd |
1.3.6.1.4.1.2007.1.4.83.1.23.3 |
Parameter 'dcd' in event SL.23 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl23-interface |
1.3.6.1.4.1.2007.1.4.83.1.23.4 |
Parameter 'interface' in event SL.23 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects24 |
1.3.6.1.4.1.2007.1.4.83.1.24 |
Event SL.24
The user-configured frame size for this interface is larger than
the maximum that is allowed for the particular serial line device.
The size is reduced to the largest allowable one. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl24-maximum-size |
1.3.6.1.4.1.2007.1.4.83.1.24.2 |
Parameter 'maximum-size' in event SL.24 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl24-interface |
1.3.6.1.4.1.2007.1.4.83.1.24.3 |
Parameter 'interface' in event SL.24 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects25 |
1.3.6.1.4.1.2007.1.4.83.1.25 |
Event SL.25
A bad length field or truncated packet was detected in a SRT bridge
packet. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl25-actual-length |
1.3.6.1.4.1.2007.1.4.83.1.25.1 |
Parameter 'actual-length' in event SL.25 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl25-claimed-length |
1.3.6.1.4.1.2007.1.4.83.1.25.2 |
Parameter 'claimed-length' in event SL.25 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl25-interface |
1.3.6.1.4.1.2007.1.4.83.1.25.3 |
Parameter 'interface' in event SL.25 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects26 |
1.3.6.1.4.1.2007.1.4.83.1.26 |
Event SL.26
An Incoming Serial Line packet is shorter than a minimally required
Serial Line header. Such packet can not be processed and hence freed. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl26-actual-length |
1.3.6.1.4.1.2007.1.4.83.1.26.1 |
Parameter 'actual-length' in event SL.26 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl26-interface |
1.3.6.1.4.1.2007.1.4.83.1.26.2 |
Parameter 'interface' in event SL.26 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects27 |
1.3.6.1.4.1.2007.1.4.83.1.27 |
Event SL.27
There is no level converter on this port of the Quad Serial Line card.
The self-test will fail, and future self-tests will be cancelled. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl27-interface |
1.3.6.1.4.1.2007.1.4.83.1.27.1 |
Parameter 'interface' in event SL.27 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects28 |
1.3.6.1.4.1.2007.1.4.83.1.28 |
Event SL.28
There is a level converter of an unknown type on this port of
the Quad Serial Line card. The self-test will fail, and future
self-tests will be cancelled. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl28-converter-type |
1.3.6.1.4.1.2007.1.4.83.1.28.1 |
Parameter 'converter-type' in event SL.28 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl28-interface |
1.3.6.1.4.1.2007.1.4.83.1.28.2 |
Parameter 'interface' in event SL.28 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects29 |
1.3.6.1.4.1.2007.1.4.83.1.29 |
Event SL.29
The user-configured frame size for this interface is smaller than
the minimum that is required for the particular serial line device.
The size is increased to the minimum allowable one. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl29-minimum-size |
1.3.6.1.4.1.2007.1.4.83.1.29.2 |
Parameter 'minimum-size' in event SL.29 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl29-interface |
1.3.6.1.4.1.2007.1.4.83.1.29.3 |
Parameter 'interface' in event SL.29 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects30 |
1.3.6.1.4.1.2007.1.4.83.1.30 |
Event SL.30
The maintenance routine is attempting to send a maintenance frame for
Proteon Serial data-link, but the buffer for sending this has not been
freed since the previous maintenance. If this happens 3 times in a row,
maintenance will fail at the other end of the serial line. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl30-interface |
1.3.6.1.4.1.2007.1.4.83.1.30.1 |
Parameter 'interface' in event SL.30 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects31 |
1.3.6.1.4.1.2007.1.4.83.1.31 |
Event SL.31
A buffer could not be allocated when needed to read the statistics
counters from the Dual Serial interface.
The counters should be successfully updated at the next maintenance,
4 seconds later. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl31-interface |
1.3.6.1.4.1.2007.1.4.83.1.31.1 |
Parameter 'interface' in event SL.31 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects32 |
1.3.6.1.4.1.2007.1.4.83.1.32 |
Event SL.32
The allocation of a packet buffer for a DNX 300 serial line failed.
This may be due to a shortage of either buffer memory or heap memory.
(See the output of ELS messages GW.061, GW.063, and GW.064).
The interface will still try and come up, but with a reduced number of
receive packet buffers. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl32-buffer-number |
1.3.6.1.4.1.2007.1.4.83.1.32.1 |
Parameter 'buffer-number' in event SL.32 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl32-interface |
1.3.6.1.4.1.2007.1.4.83.1.32.2 |
Parameter 'interface' in event SL.32 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects33 |
1.3.6.1.4.1.2007.1.4.83.1.33 |
Event SL.33
A packet buffer was allocated for the DNX 300 serial line, but that
buffer crossed a 64 Kbyte memory boundary in the buffer memory. Since
all of the receive buffers for a DNX 300 serial line must be
in the same 64 Kbyte buffer memory packet, that buffer will be ignored,
and no further buffers will be allocated for the device. The interface
will still try and come up, but with a reduced number of receive packet
buffers. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl33-buffer-number |
1.3.6.1.4.1.2007.1.4.83.1.33.1 |
Parameter 'buffer-number' in event SL.33 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl33-interface |
1.3.6.1.4.1.2007.1.4.83.1.33.2 |
Parameter 'interface' in event SL.33 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects34 |
1.3.6.1.4.1.2007.1.4.83.1.34 |
Event SL.34
The system does not detect an adapter cable in the network interface
port. Self-test will fail. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl34-interface |
1.3.6.1.4.1.2007.1.4.83.1.34.1 |
Parameter 'interface' in event SL.34 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects35 |
1.3.6.1.4.1.2007.1.4.83.1.35 |
Event SL.35
A protocol that cannot be bridged by Proteon Serial Line's PSEUDO-
ETHERNET bridging method has been configured over an interface
using PSL PSEUDO-ETH. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl35-protocol-name |
1.3.6.1.4.1.2007.1.4.83.1.35.1 |
Parameter 'protocol-name' in event SL.35 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sl35-protocol-number |
1.3.6.1.4.1.2007.1.4.83.1.35.2 |
Parameter 'protocol-number' in event SL.35 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
sl35-interface |
1.3.6.1.4.1.2007.1.4.83.1.35.3 |
Parameter 'interface' in event SL.35 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slEventObjects36 |
1.3.6.1.4.1.2007.1.4.83.1.36 |
Event SL.36
The interface is on mode loopback or echo and the timeout as expired. |
Status: current |
Access: accessible-for-notify |
OBJECT-IDENTITY |
|
|
|
sl36-interface |
1.3.6.1.4.1.2007.1.4.83.1.36.1 |
Parameter 'interface' in event SL.36 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
slNotification1 |
1.3.6.1.4.1.2007.1.4.83.2.0.1 |
Notification of Event SL.1
Message: 'no buffer available for selftest interface $1'
Parameters list:
$1: sl1-interface
A packet buffer was not available when the interface self-test
needed one. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification2 |
1.3.6.1.4.1.2007.1.4.83.2.0.2 |
Notification of Event SL.2
Message: 'modem error with no DCD/DTS detected during selftest interface $1'
Parameters list:
$1: sl2-interface
During the self-test, the interface card detected that certain signals
from modem necessary to indicate that it is present and ready to operate
were not detectable. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification3 |
1.3.6.1.4.1.2007.1.4.83.2.0.3 |
Notification of Event SL.3
Message: 'no echo acknowledgement received, timeout selftest interface $1'
Parameters list:
$1: sl3-interface
During self-test, an Echo Acknowledgement was not received from the
other end of the line within the timeout period. The network fails
self-test. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification4 |
1.3.6.1.4.1.2007.1.4.83.2.0.4 |
Notification of Event SL.4
Message: 'bad length in DECNet packet actual $1 claimed $2 interface $3'
Parameters list:
$1: sl4-actual-length
$2: sl4-claimed-length
$3: sl4-interface
A bad length field or truncated packet was detected in a DECnet packet
on the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification5 |
1.3.6.1.4.1.2007.1.4.83.2.0.5 |
Notification of Event SL.5
Message: 'bad received packet header opcode $1 interface $2'
Parameters list:
$1: sl5-opcode
$2: sl5-interface
A network control packet was received with a packet type which did not
match any known opcode. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification6 |
1.3.6.1.4.1.2007.1.4.83.2.0.6 |
Notification of Event SL.6
Message: 'bad received packet header protocol $1 interface $2'
Parameters list:
$1: sl6-protocol
$2: sl6-interface
A serial line packet was received with a higher level protocol which
did not match any known protocol. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification7 |
1.3.6.1.4.1.2007.1.4.83.2.0.7 |
Notification of Event SL.7
Message: 'start selftest interface $1'
Parameters list:
$1: sl7-interface
Self-test is being started on the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification8 |
1.3.6.1.4.1.2007.1.4.83.2.0.8 |
Notification of Event SL.8
Message: 'send echo packet interface $1'
Parameters list:
$1: sl8-interface
An echo request is being sent on the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification9 |
1.3.6.1.4.1.2007.1.4.83.2.0.9 |
Notification of Event SL.9
Message: 'receive test packet interface $1'
Parameters list:
$1: sl9-interface
A test packet has been received on the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification10 |
1.3.6.1.4.1.2007.1.4.83.2.0.10 |
Notification of Event SL.10
Message: 'receive echo acknowledgement packet interface $1'
Parameters list:
$1: sl10-interface
An echo acknowledgement packet has been received on the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification11 |
1.3.6.1.4.1.2007.1.4.83.2.0.11 |
Notification of Event SL.11
Message: 'receive echo request packet interface $1'
Parameters list:
$1: sl11-interface
An echo acknowledgement packet has been received on the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification12 |
1.3.6.1.4.1.2007.1.4.83.2.0.12 |
Notification of Event SL.12
Message: 'sending maintenance test packet interface $1'
Parameters list:
$1: sl12-interface
A test packet used for network maintenence is being sent on
the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification13 |
1.3.6.1.4.1.2007.1.4.83.2.0.13 |
Notification of Event SL.13
Message: 'Dropping the received Spanning Tree Bridged packet but bridging is disabled on interface $1'
Parameters list:
$1: sl13-interface
A Bridged packet is received on this serial line interface even though
the Spanning Tree Bridging is not enabled on this interface or STB
is disabled in the box. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification14 |
1.3.6.1.4.1.2007.1.4.83.2.0.14 |
Notification of Event SL.14
Message: 'Dual Serial Line board in slot $1 firmware download $2'
Parameters list:
$1: sl14-slot-num
$2: sl14-ld-code
Dual Serial Line Interface board firmware download has completed with
the status shown. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification15 |
1.3.6.1.4.1.2007.1.4.83.2.0.15 |
Notification of Event SL.15
Message: 'Dual Serial Line board slot $1 Power-On Diagnostics status $2'
Parameters list:
$1: sl15-slot-num
$2: sl15-pud-stat
Dual Serial Line Board Power-On Diagnostics status completed with the
code shown. See Power-On Diagnostics manual for encoding. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification16 |
1.3.6.1.4.1.2007.1.4.83.2.0.16 |
Notification of Event SL.16
Message: '$1 type pakcet filtered for protocol = $2 interface $3'
Parameters list:
$1: sl16-protocol-type
$2: sl16-protocol
$3: sl16-interface
Protocol type like Ethertype, DSAPytype or SNAPtype packet filtered.
This is due to the user supplied protocol filtering information. (STB). |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification17 |
1.3.6.1.4.1.2007.1.4.83.2.0.17 |
Notification of Event SL.17
Message: 'Dropped, protocol = $1 enabled but packet arrived as bridged from address $2, interface $3'
Parameters list:
$1: sl17-protocol-type
$2: sl17-src-addr
$3: sl17-interface
Packet dropped as the protocol type is enabled but packet arrived
as bridged. (STB). |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification18 |
1.3.6.1.4.1.2007.1.4.83.2.0.18 |
Notification of Event SL.18
Message: 'Dropped, dsap = $1, Protocol filtreing applies, interface $2'
Parameters list:
$1: sl18-protocol-type
$2: sl18-interface
Packet dropped as the protocol filtering applies (STB). |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification19 |
1.3.6.1.4.1.2007.1.4.83.2.0.19 |
Notification of Event SL.19
Message: 'Cable of type $1 is not compatible with level converter of type $2, interface $3'
Parameters list:
$1: sl19-cable-type
$2: sl19-level-converter-type
$3: sl19-interface
The cable and the level converter on the interface are not compatible
with each other. The self-test will fail. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification20 |
1.3.6.1.4.1.2007.1.4.83.2.0.20 |
Notification of Event SL.20
Message: '$1 cable cannot be used with $2 clocking enabled, interface $3'
Parameters list:
$1: sl20-cable-type
$2: sl20-internal-external
$3: sl20-interface
There is an incompatibility between the mode of the cable (DCE or DTE)
and the type of clocking used. The interface will not be brought up. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification21 |
1.3.6.1.4.1.2007.1.4.83.2.0.21 |
Notification of Event SL.21
Message: 'Self test failed because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4'
Parameters list:
$1: sl21-cts
$2: sl21-dsr
$3: sl21-dcd
$4: sl21-interface
The interface failed self test because at least one of the
modem signals was off. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification22 |
1.3.6.1.4.1.2007.1.4.83.2.0.22 |
Notification of Event SL.22
Message: 'Modem status change CTS = $1, DSR = $2, DCD = $3, on interface $4'
Parameters list:
$1: sl22-cts
$2: sl22-dsr
$3: sl22-dcd
$4: sl22-interface
A modem status change has occurred. The present state is described. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification23 |
1.3.6.1.4.1.2007.1.4.83.2.0.23 |
Notification of Event SL.23
Message: 'Interface down because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4'
Parameters list:
$1: sl23-cts
$2: sl23-dsr
$3: sl23-dcd
$4: sl23-interface
The interface was brought down because one of the modem signals was off. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification24 |
1.3.6.1.4.1.2007.1.4.83.2.0.24 |
Notification of Event SL.24
Message: 'Configured frame size of $1 bytes too large, reducing to $2 bytes, interface $3'
Parameters list:
$1: sl24-configured-size
$2: sl24-maximum-size
$3: sl24-interface
The user-configured frame size for this interface is larger than
the maximum that is allowed for the particular serial line device.
The size is reduced to the largest allowable one. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification25 |
1.3.6.1.4.1.2007.1.4.83.2.0.25 |
Notification of Event SL.25
Message: 'bad length in SRT packet actual $1 claimed $2 interface $3'
Parameters list:
$1: sl25-actual-length
$2: sl25-claimed-length
$3: sl25-interface
A bad length field or truncated packet was detected in a SRT bridge
packet. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification26 |
1.3.6.1.4.1.2007.1.4.83.2.0.26 |
Notification of Event SL.26
Message: 'Packet received is shorter than Serial line header, actual $1 interface $2'
Parameters list:
$1: sl26-actual-length
$2: sl26-interface
An Incoming Serial Line packet is shorter than a minimally required
Serial Line header. Such packet can not be processed and hence freed. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification27 |
1.3.6.1.4.1.2007.1.4.83.2.0.27 |
Notification of Event SL.27
Message: 'No level converter, disabling interface $1'
Parameters list:
$1: sl27-interface
There is no level converter on this port of the Quad Serial Line card.
The self-test will fail, and future self-tests will be cancelled. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification28 |
1.3.6.1.4.1.2007.1.4.83.2.0.28 |
Notification of Event SL.28
Message: 'Unknown level converter type $1, disabling interface $2'
Parameters list:
$1: sl28-converter-type
$2: sl28-interface
There is a level converter of an unknown type on this port of
the Quad Serial Line card. The self-test will fail, and future
self-tests will be cancelled. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification29 |
1.3.6.1.4.1.2007.1.4.83.2.0.29 |
Notification of Event SL.29
Message: 'Configured frame size of $1 bytes too small, increasing to $2 bytes, interface $3'
Parameters list:
$1: sl29-configured-size
$2: sl29-minimum-size
$3: sl29-interface
The user-configured frame size for this interface is smaller than
the minimum that is required for the particular serial line device.
The size is increased to the minimum allowable one. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification30 |
1.3.6.1.4.1.2007.1.4.83.2.0.30 |
Notification of Event SL.30
Message: 'Maintenance buffer busy, interface $1'
Parameters list:
$1: sl30-interface
The maintenance routine is attempting to send a maintenance frame for
Proteon Serial data-link, but the buffer for sending this has not been
freed since the previous maintenance. If this happens 3 times in a row,
maintenance will fail at the other end of the serial line. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification31 |
1.3.6.1.4.1.2007.1.4.83.2.0.31 |
Notification of Event SL.31
Message: 'No packet for reading counters, interface $1'
Parameters list:
$1: sl31-interface
A buffer could not be allocated when needed to read the statistics
counters from the Dual Serial interface.
The counters should be successfully updated at the next maintenance,
4 seconds later. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification32 |
1.3.6.1.4.1.2007.1.4.83.2.0.32 |
Notification of Event SL.32
Message: 'Packet buffer allocation number $1 failed, interface $2'
Parameters list:
$1: sl32-buffer-number
$2: sl32-interface
The allocation of a packet buffer for a DNX 300 serial line failed.
This may be due to a shortage of either buffer memory or heap memory.
(See the output of ELS messages GW.061, GW.063, and GW.064).
The interface will still try and come up, but with a reduced number of
receive packet buffers. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification33 |
1.3.6.1.4.1.2007.1.4.83.2.0.33 |
Notification of Event SL.33
Message: 'Packet buffer number $1 crossed 64 Kbyte page boundary, dropped, ifc $2'
Parameters list:
$1: sl33-buffer-number
$2: sl33-interface
A packet buffer was allocated for the DNX 300 serial line, but that
buffer crossed a 64 Kbyte memory boundary in the buffer memory. Since
all of the receive buffers for a DNX 300 serial line must be
in the same 64 Kbyte buffer memory packet, that buffer will be ignored,
and no further buffers will be allocated for the device. The interface
will still try and come up, but with a reduced number of receive packet
buffers. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification34 |
1.3.6.1.4.1.2007.1.4.83.2.0.34 |
Notification of Event SL.34
Message: 'No cable installed or installed cable broken or non-compatible, interface $1'
Parameters list:
$1: sl34-interface
The system does not detect an adapter cable in the network interface
port. Self-test will fail. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification35 |
1.3.6.1.4.1.2007.1.4.83.2.0.35 |
Notification of Event SL.35
Message: 'Protocol $1 ($2) can not be bridged over Proteon Serial Line using the pseudo-ethernet bridging method. Interface $3'
Parameters list:
$1: sl35-protocol-name
$2: sl35-protocol-number
$3: sl35-interface
A protocol that cannot be bridged by Proteon Serial Line's PSEUDO-
ETHERNET bridging method has been configured over an interface
using PSL PSEUDO-ETH. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
slNotification36 |
1.3.6.1.4.1.2007.1.4.83.2.0.36 |
Notification of Event SL.36
Message: 'warning: test on ifc $1'
Parameters list:
$1: sl36-interface
The interface is on mode loopback or echo and the timeout as expired. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|