Wellfleet-OC12-MIB
File:
Wellfleet-OC12-MIB.mib (5976 bytes)
Imported modules
Imported symbols
Defined Types
WfOc12ConfigEntry |
|
SEQUENCE |
|
|
|
|
wfOc12ConfigDelete |
INTEGER |
|
|
wfOc12ConfigDisable |
INTEGER |
|
|
wfOc12ConfigIndex |
INTEGER |
|
|
wfOc12ConfigIfIndex |
INTEGER |
|
|
wfOc12ConfigState |
INTEGER |
|
|
wfOc12ConfigLineStatus |
INTEGER |
|
|
wfOc12ConfigLastChange |
TimeTicks |
|
|
wfOc12ConfigType |
INTEGER |
|
|
wfOc12ConfigLineCoding |
INTEGER |
|
|
wfOc12ConfigLineType |
INTEGER |
|
|
wfOc12ConfigLoopbackConfig |
INTEGER |
|
|
wfOc12ConfigManagerMethod |
INTEGER |
|
Defined Values
wfOc12ConfigEntry |
1.3.6.1.4.1.18.3.4.24.20.1 |
An entry in the medium table |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
WfOc12ConfigEntry |
|
|
wfOc12ConfigDelete |
1.3.6.1.4.1.18.3.4.24.20.1.1 |
Create/Delete parameter |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
created(1), deleted(2) |
|
wfOc12ConfigDisable |
1.3.6.1.4.1.18.3.4.24.20.1.2 |
Create/Delete parameter |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
wfOc12ConfigIndex |
1.3.6.1.4.1.18.3.4.24.20.1.3 |
Index for this physical Sonet interface. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
wfOc12ConfigIfIndex |
1.3.6.1.4.1.18.3.4.24.20.1.4 |
this is value of ifIndex from the Interfaces table of
MIB II (RFC 1213). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
wfOc12ConfigState |
1.3.6.1.4.1.18.3.4.24.20.1.5 |
State of the OC12 Port. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2), los(3), lof(4), ais(5), rdi(6), loopback(7), notpresent(20) |
|
wfOc12ConfigLineStatus |
1.3.6.1.4.1.18.3.4.24.20.1.6 |
the status of the OC12 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noalarm(1), los(2), lof(4), ais(8), rdi(16), loopback(128), otherfailure(512) |
|
wfOc12ConfigLastChange |
1.3.6.1.4.1.18.3.4.24.20.1.7 |
The value of sysUpTime at the time the interface entered
its current operational state. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
wfOc12ConfigType |
1.3.6.1.4.1.18.3.4.24.20.1.8 |
This variable identifies whether a SONET or a SDH signal is used
across this interface. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
sonet(1), sdh(2) |
|
wfOc12ConfigLineCoding |
1.3.6.1.4.1.18.3.4.24.20.1.9 |
This variable describes the line coding for this interface. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), b3zs(2), cmi(3), nrz(4), rz(5) |
|
wfOc12ConfigLineType |
1.3.6.1.4.1.18.3.4.24.20.1.10 |
This variable describes the line type for this interface. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), shortsinglemode(2), longsinglemode(3), multimode(4), coax(5), utp(6) |
|
wfOc12ConfigLoopbackConfig |
1.3.6.1.4.1.18.3.4.24.20.1.11 |
the loopback configuration of the OC12 interface |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noloop(1), payloadloop(2), lineloop(3) |
|
wfOc12ConfigManagerMethod |
1.3.6.1.4.1.18.3.4.24.20.1.12 |
This attribute has no affect on the Hardware configuration.
This attribute is purely for any Network Management Tool
to determine whether it configured the OC12 as Fractional
or Clear. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
frac(1), clear(2) |
|