XYLAN-SONET-MIB
File:
XYLAN-SONET-MIB.mib (4540 bytes)
Imported modules
Imported symbols
Defined Types
XylanSonetEntry |
|
SEQUENCE |
|
|
|
|
xylanSonetStatsEnable |
INTEGER |
|
|
xylanSonetNumOfSamples |
INTEGER |
|
|
xylanSonetClearCurrentSample |
INTEGER |
|
Defined Values
xylanSonetTable |
1.3.6.1.4.1.800.2.23.1.1 |
The SONET error statistics gathering configuration table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
XylanSonetEntry |
|
xylanSonetEntry |
1.3.6.1.4.1.800.2.23.1.1.1 |
An entry in the SONET/SDH Medium table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
XylanSonetEntry |
|
|
xylanSonetStatsEnable |
1.3.6.1.4.1.800.2.23.1.1.1.1 |
A value that indicates whether the SONET error
statistics is enabled or not. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
xylanSonetNumOfSamples |
1.3.6.1.4.1.800.2.23.1.1.1.2 |
The number of samples to be stored in the interval tables.
This variable can be set only if Sonet Error Collection
is enabled on the interface. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
4..96 |
|
xylanSonetClearCurrentSample |
1.3.6.1.4.1.800.2.23.1.1.1.3 |
This variable indicates which layer error statistics are
to be cleared. When this variable is set, the corresponding
current interval sample will be cleared.
The xylanSonetClearCurrentSample is a bit map represented
as a sum. So multiple tables can be cleared by one set.
The bit positions are :
0 None
1 Section
2 Line
4 FarEndLine
8 Path
16 FarEndPath
31 All |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..31 |
|
xylanSonetSlotIndex |
1.3.6.1.4.1.800.2.23.3.1 |
A unique value which identifies this switch slot. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..9 |
|
xylanSonetPortIndex |
1.3.6.1.4.1.800.2.23.3.2 |
A unique value which identifies this switch slot/port. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..9 |
|
xylanSonetHardwareIndex |
1.3.6.1.4.1.800.2.23.3.3 |
A unique value which identifies the hardware on the
switch slot/port where the error has occured |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
xylanSonetErrType |
1.3.6.1.4.1.800.2.23.3.4 |
A unique value which identifies the type of AIS error
that has occured on the Sonet hardware. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|