| RFC1155-SMI | RFC1213-MIB | RFC-1215 |
| ACC-MIB | ACC-SYSTEM |
| accSlot | 1.3.6.1.4.1.5.1.1.5 | ||
| OBJECT IDENTIFIER | |||
| accSlotTable | 1.3.6.1.4.1.5.1.1.5.2 | ||
| A list of physical port entries. The number of entries is given by the value of accSlotNum. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AccSlotEntry | |||
| accSlotEntry | 1.3.6.1.4.1.5.1.1.5.2.1 | ||
| A table entry providing information about a specific physical port. | |||
| OBJECT-TYPE | |||
| AccSlotEntry | |||
| accSlotInPkts | 1.3.6.1.4.1.5.1.1.5.2.1.11 | ||
| Number of packets received on this physical interface. | |||
| OBJECT-TYPE | |||
| Counter | |||
| accSlotOutPkts | 1.3.6.1.4.1.5.1.1.5.2.1.17 | ||
| Number of packets transmitted on this physical interface. | |||
| OBJECT-TYPE | |||
| Counter | |||
| accSlotNumChanges | 1.3.6.1.4.1.5.1.1.5.2.1.21 | ||
| Number of times that this interface has changed state (either up-to-down or down-to-up). | |||
| OBJECT-TYPE | |||
| Counter | |||
| accSlotProtocol | 1.3.6.1.4.1.5.1.1.5.2.1.22 | ||
| Protocol used on this slot. note that these enumerated values match those in accBrPortProtocol. | |||
| OBJECT-TYPE | |||
| INTEGER | enet(1), x25(2), lapb(3), ffr(4), other(5), token-ring(6), smds(7), ppp(8), fddi(9), dial(10), multilink(11) | ||
| accSlotClockMode | 1.3.6.1.4.1.5.1.1.5.2.1.23 | ||
| Clock mode of this port | |||
| OBJECT-TYPE | |||
| INTEGER | unknown(1), ext1(2), pp(3), ext2(4), int(5), slave(6) | ||
| accSlotQueueMode | 1.3.6.1.4.1.5.1.1.5.2.1.24 | ||
| Queuing mode for this slot Fair queuing provides per-conversation bandwidth allocation, with additional bandwidth allocated to higher priority traffic. Precedence queueing gives first-in-first-out service amongst priority queues. | |||
| OBJECT-TYPE | |||
| INTEGER | express(1), precedence(2) | ||
| accSlotDialProcedure | 1.3.6.1.4.1.5.1.1.5.2.1.25 | ||
| Dial Procedure. | |||
| OBJECT-TYPE | |||
| INTEGER | lan(1), direct(2), x21(3), dtr(4), isdn(5), v25(6), hayes(7), tdm(8) | ||
| accSlotResyncMode | 1.3.6.1.4.1.5.1.1.5.2.1.26 | ||
| Establishes operational mode of the Resync function for crypto gear. When active, a link-down condition intitiates resynchronization, which is manifested by setting the DTR (RTS) signal active (low) for 10 milliseconds. | |||
| OBJECT-TYPE | |||
| INTEGER | on(1), off(2) | ||
| accSlotCompressMode | 1.3.6.1.4.1.5.1.1.5.2.1.27 | ||
| Establishes operational mode of Data Compression. This functionality is appropriate for serial lines. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2) | ||
| accSlotCompressV42bisP1 | 1.3.6.1.4.1.5.1.1.5.2.1.29 | ||
| Number of codewords | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accSlotCompressV42bisP2 | 1.3.6.1.4.1.5.1.1.5.2.1.30 | ||
| Maximum string size | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accSlotCompressDcs221P1 | 1.3.6.1.4.1.5.1.1.5.2.1.31 | ||
| Compression Mode | |||
| OBJECT-TYPE | |||
| INTEGER | none(0), fast(1), normal(2), medium(3), slow(4) | ||
| accSlotSevereCongPct | 1.3.6.1.4.1.5.1.1.5.2.1.32 | ||
| Percent Congested | |||
| OBJECT-TYPE | |||
| INTEGER | 1..100 | ||
| accSlotDialAddress | 1.3.6.1.4.1.5.1.1.5.2.1.33 | ||
| Dial Address. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| accSlotCompressRevision | 1.3.6.1.4.1.5.1.1.5.2.1.34 | ||
| Indicates which data compression algorithm should be used for this physical port. If the confi gured protocol is Frame Relay, X.25 or PPP, the com pression mode must be new. If the configured protocol is LAPB, OLD indicates that the neighbor is running a release which predates 7.2 and the old compression algorithm should be used. | |||
| OBJECT-TYPE | |||
| INTEGER | old(1), new(2) | ||
| accSlotCompressMaxStreams | 1.3.6.1.4.1.5.1.1.5.2.1.35 | ||
| The maximum number of independent data streams for this physical port. This object determines the size of the history buffer pool. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accSlotCompressMessageLevel | 1.3.6.1.4.1.5.1.1.5.2.1.36 | ||
| . | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accSlotIfType | 1.3.6.1.4.1.5.1.1.5.2.1.37 | ||
| . | |||
| OBJECT-TYPE | |||
| INTEGER | unpopulated(0), lance-ethernet(1), sWAN-port(2), token-Ring(3), intel-ethernet(4), serial(5), sonic-ethernet(6), isdn-D-channel(7), hWAN-Port(8), icp-isdn-B-channel(9), icp-isdn-D-channel(10), dWAN-port(11), x-21(12), rs-422(13), rs-232(14), v-35(15), isdn-S(16), isdn-U(17), other(18), not-Installed(19), lance-10base5-Ethernet(20), lance-10baseT-Ethernet(21), lance-10base2-Ethernet(22), lance-empty-Ethernet(23), sonic-empty-Ethernet(30), sonic-10base2-Ethernet(31), sonic-10baseT-Ethernet(32), sonic-10base5-Ethernet(33), hWAN-port-RS-232(40), hWAN-port-other(41), hWAN-port-V-35(42), hWAN-port-X-21(43), hWAN-port-RS-422(44), pri-e1(45), pri-t1(46), uwan-faulty-cable(50), uwan-x-21-dce(51), uwan-v-35-dce(52), uwan-rs-232-dce(53), uwan-x-21-dte(54), uwan-v-35-dte(55), uwan-rs-232-dte(56), uwan-unconnected(57), rs-232-dte(58), volatile(59), v-34-digital-modem(61), dec-100baseTXfull-ethernet(62), dec-100baseTXhalf-ethernet(63), dec-10baseTfull-ethernet(64), dec-10baseThalf-ethernet(65) | ||
| accSlotE1FrameMode | 1.3.6.1.4.1.5.1.1.5.2.1.38 | ||
| . | |||
| OBJECT-TYPE | |||
| INTEGER | unpopulated(0), lance-ethernet(1), sWAN-port(2), token-Ring(3), intel-ethernet(4), serial(5), sonic-ethernet(6), isdn-D-channel(7), hWAN-Port(8), icp-isdn-B-channel(9), icp-isdn-D-channel(10), dWAN-port(11), x-21(12), rs-422(13), rs-232(14), v-35(15), isdn-S(16), isdn-U(17), other(18), not-Installed(19), lance-10base5-Ethernet(20), lance-10baseT-Ethernet(21), lance-10base2-Ethernet(22), lance-empty-Ethernet(23), sonic-empty-Ethernet(30), sonic-10base2-Ethernet(31), sonic-10baseT-Ethernet(32), sonic-10base5-Ethernet(33), hWAN-port-RS-232(40), hWAN-port-other(41), hWAN-port-V-35(42), hWAN-port-X-21(43), hWAN-port-RS-422(44) | ||
| accSlotLastChangeY2K | 1.3.6.1.4.1.5.1.1.5.2.1.39 | ||
| Time when a state change was last detected on this physical port. The seven byte long octet string represents year 2000 compliant date and time, and is laid out in the following structured format: 2 Byte unsigned short value of year 1 Byte value of month 1 Byte value of day of the month 1 Byte value of hour 1 Byte value of minutes 1 Byte value of seconds | |||
| OBJECT-TYPE | |||
| OCTET STRING | |||
| accCardSlotTable | 1.3.6.1.4.1.5.1.1.5.3 | ||
| A table providing objects for each installed card in the system chassis slots. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AccCardSlotEntry | |||
| accCardSlotEntry | 1.3.6.1.4.1.5.1.1.5.3.1 | ||
| Contains a summary of objects for a slot entry. | |||
| OBJECT-TYPE | |||
| AccCardSlotEntry | |||
| accCardSlotNum | 1.3.6.1.4.1.5.1.1.5.3.1.1 | ||
| An integer that uniquely identifies the card slot within the system chassis. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardSlotType | 1.3.6.1.4.1.5.1.1.5.3.1.2 | ||
| An integer value which uniquely identifies the card type. | |||
| OBJECT-TYPE | |||
| INTEGER | unknown-card(1), carrier-card(2), control-card(3), e1-t1-card(4), modem-card(5) | ||
| accCardSlotRevNum | 1.3.6.1.4.1.5.1.1.5.3.1.3 | ||
| A printable ASCII string representing the card rev number. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| accCardSlotSerNum | 1.3.6.1.4.1.5.1.1.5.3.1.4 | ||
| A printable ASCII string representing the card serial num. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| accCardSlotPortCnf | 1.3.6.1.4.1.5.1.1.5.3.1.5 | ||
| A printable ASCII string representing the interface configuration on this slot. | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| accCardSlotAdminState | 1.3.6.1.4.1.5.1.1.5.3.1.6 | ||
| An integer value which uniquely identifies the card administration state. | |||
| OBJECT-TYPE | |||
| INTEGER | online(1), offfine(2) | ||
| accCardSlotOperState | 1.3.6.1.4.1.5.1.1.5.3.1.7 | ||
| An integer value which uniquely identifies the card operational state. | |||
| OBJECT-TYPE | |||
| INTEGER | ready(1), offline(2), removed(3), downloading(4), file-sync-error(5), config-error(6), test(7), deactivated(8), standby(9) | ||
| accCardSlotIndex | 1.3.6.1.4.1.5.1.1.5.3.1.8 | ||
| The ifIndex for this slot. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardSlotNum11Slot | 1.3.6.1.4.1.5.1.1.5.3.1.9 | ||
| An integer that uniquely identifies the card slot within the 11-Slot system chassis. This can be used as an alternate index into accCardSlotTable. | |||
| OBJECT-TYPE | |||
| INTEGER | j0(1), j1(2), j2(3), j3(4), j4A(5), j4B(6), j5(7), j6(8), j7(9), j8(10), j9(11) | ||
| accCardInterfaceTable | 1.3.6.1.4.1.5.1.1.5.4 | ||
| A table providing interface information for each interface on the system indicating how they relate to system slots. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AccCardInterfaceEntry | |||
| accCardInterfaceEntry | 1.3.6.1.4.1.5.1.1.5.4.1 | ||
| Contains a summary of objects for an interface entry. | |||
| OBJECT-TYPE | |||
| AccCardInterfaceEntry | |||
| accCardInterfaceNum | 1.3.6.1.4.1.5.1.1.5.4.1.1 | ||
| An integer that uniquely identifies the interface within the slot card. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardInterfaceType | 1.3.6.1.4.1.5.1.1.5.4.1.2 | ||
| The interface type - need to define enumerations here !! | |||
| OBJECT-TYPE | |||
| INTEGER | ethernet(1), generic-wan(2), tokenring(3), isdn-capable-e1(4), isdn-capable-t1(5), bri-u(6), bri-s(7), digital-modem(8) | ||
| accCardInterfaceSlotNum | 1.3.6.1.4.1.5.1.1.5.4.1.3 | ||
| The slot number that this interface resides on - corresponds to accCardSlotNum. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardInterfaceIndex | 1.3.6.1.4.1.5.1.1.5.4.1.4 | ||
| The ifIndex for this interface. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardCircuitTable | 1.3.6.1.4.1.5.1.1.5.5 | ||
| A table providing information for each circuit installed in the system chassis, indicating how they relate to slots and interfaces. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AccCardCircuitEntry | |||
| accCardCircuitEntry | 1.3.6.1.4.1.5.1.1.5.5.1 | ||
| Contains a summary of objects for a circuit entry. | |||
| OBJECT-TYPE | |||
| AccCardCircuitEntry | |||
| accCardCircuitNum | 1.3.6.1.4.1.5.1.1.5.5.1.1 | ||
| An integer that uniquely identifies the circuit within the interface. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardCircuitSlotNum | 1.3.6.1.4.1.5.1.1.5.5.1.2 | ||
| The slot number that this circuit resides on - corresponds to accCardSlotNum. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardCircuitInterfaceNum | 1.3.6.1.4.1.5.1.1.5.5.1.3 | ||
| The interface number that this circuit resides on - corresponds to accCardInterfaceNum. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardCircuitIndex | 1.3.6.1.4.1.5.1.1.5.5.1.4 | ||
| The ifIndex for this circuit. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| accCardSlotTraps | 1.3.6.1.4.1.5.1.1.5.6 | ||
| OBJECT IDENTIFIER | |||
| accCardSlotTrapMsg | 1.3.6.1.4.1.5.1.1.5.6.1 | ||
| Enterprise Trap Message for CardSlot | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| accRmReqResetTrap | 1.3.6.1.4.1.5.1.1.5.6.1 | ||
| This trap is generated when a particular command which is a part of feature that is set to ON from OFF using the EME feature indicating that a reload can actually bring that feature effective. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accMemEMEStatus | |||
| accTrapLogSeqNum | |||
| accRmFeatureTrap | 1.3.6.1.4.1.5.1.1.5.6.2 | ||
| This trap is generated when a particular command which is a part of feature that is set to OFF using the EME feature. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accMemOptimiserMemory | |||
| accMemOptimiserPref | |||
| accMemOptimiserFeature | |||
| accMemOptimiserStatus | |||
| accTrapLogSeqNum | |||
| accRmCardRemovedTrap | 1.3.6.1.4.1.5.1.1.5.6.3 | ||
| This indicates that a Card has been removed and tried to acticvate or deactivate the respective card SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmActvComplTrap | 1.3.6.1.4.1.5.1.1.5.6.4 | ||
| When the command to activate a card is issued. This trap indicates the activation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmActvStartTrap | 1.3.6.1.4.1.5.1.1.5.6.5 | ||
| When the command to activate card is issued. This trap indicates the activation has started SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmActvFailTrap | 1.3.6.1.4.1.5.1.1.5.6.6 | ||
| When the command (set slot state) to activate card is issued. This trap is generated in case of a failure or Mismatch of the slot. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmDeActvStartTrap | 1.3.6.1.4.1.5.1.1.5.6.7 | ||
| When the command (set slot state) to deactivate card is issued. This trap indicates the deactivation has started. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmDeActvComplTrap | 1.3.6.1.4.1.5.1.1.5.6.8 | ||
| When the command (set slot state) to deactivate a card is issued. This trap indicates the deactivation was sucessfully done SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmCardRemvdTrap | 1.3.6.1.4.1.5.1.1.5.6.9 | ||
| This indicates that a Card has been removed after deactivating the slot using the set slot state command SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmInvStateTrap | 1.3.6.1.4.1.5.1.1.5.6.10 | ||
| If the card is BUSY and cannot be deactivated this trap is generated SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmFaultHndlTrap | 1.3.6.1.4.1.5.1.1.5.6.11 | ||
| Fault Hndl, Invalid State SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeqNum | |||
| accRmFaultIndTrap | 1.3.6.1.4.1.5.1.1.5.6.12 | ||
| Fault Indication (reason), Slot SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 15 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accCardSlotAdminState | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmDataCallTrap | 1.3.6.1.4.1.5.1.1.5.6.13 | ||
| This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmDataEnableTrap | 1.3.6.1.4.1.5.1.1.5.6.14 | ||
| This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the initiate data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmDataCallAccptTrap | 1.3.6.1.4.1.5.1.1.5.6.15 | ||
| This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmDataSwitchTrap | 1.3.6.1.4.1.5.1.1.5.6.16 | ||
| This is the trap generated in Congo Voice router which has a physical switch for Data enable. If it is OFF and the data call request has come, then this trap can be generated. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmFrmWareLoadAbortTrap | 1.3.6.1.4.1.5.1.1.5.6.17 | ||
| This is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmBfrAllocTrap | 1.3.6.1.4.1.5.1.1.5.6.18 | ||
| This is a trap which is because of a alloc failure due to memory shortage. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmLoadAbortTrap | 1.3.6.1.4.1.5.1.1.5.6.19 | ||
| If the file is corrupted the loading is aborted and is indicated by this trap. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 253 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmFrmwrCompatiblTrap | 1.3.6.1.4.1.5.1.1.5.6.20 | ||
| If the extension is not supported by the version of the apl file then this trap is sent. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 48 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmLoadTrap5 | 1.3.6.1.4.1.5.1.1.5.6.21 | ||
| This is basically a revision mismatch. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 46 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmSwUpGradeMsgTrap | 1.3.6.1.4.1.5.1.1.5.6.22 | ||
| THIS ROUTER WILL NOT OPERATE WITH FULL FUNCTIONALITY UNTIL A VALID KEY HAS BEEN ENTERED SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmInSuffRAMTrap | 1.3.6.1.4.1.5.1.1.5.6.23 | ||
| This is a memory related trap indicating that sufficient RAM is not on the borad, so that the admin can take the appropriate action of increasing the memory or replacing the memory. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmPwrSplyMalfnTrap | 1.3.6.1.4.1.5.1.1.5.6.24 | ||
| This is a TIGRIS Power supply trap indicating that the one of the Power Supply is not OK and should be replaced. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmPwrSplyStatTrap | 1.3.6.1.4.1.5.1.1.5.6.25 | ||
| When one of the DUAL TIGRIS Power supply is removed or inserted this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmFanStatTrap | 1.3.6.1.4.1.5.1.1.5.6.26 | ||
| If the fan in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmDcStatTrap | 1.3.6.1.4.1.5.1.1.5.6.27 | ||
| If the AC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmAcStatTrap | 1.3.6.1.4.1.5.1.1.5.6.28 | ||
| If the DC componemt in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmPwr1PresTrap | 1.3.6.1.4.1.5.1.1.5.6.29 | ||
| If the power supply is removed or installed this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmPwrFan1Trap | 1.3.6.1.4.1.5.1.1.5.6.30 | ||
| If the Tigris power supply fan fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmPwrDc1Trap | 1.3.6.1.4.1.5.1.1.5.6.31 | ||
| If the Tigris power supply DC Component fails or recovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmPwrAc1Trap | 1.3.6.1.4.1.5.1.1.5.6.32 | ||
| If the Tigris power supply AC Component fails or recovered this trap is generated. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 158 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmEalm2Trap | 1.3.6.1.4.1.5.1.1.5.6.33 | ||
| Trap indicating the external 2nd alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmEalm1Trap | 1.3.6.1.4.1.5.1.1.5.6.34 | ||
| Trap indicating the external 1st alarm status of the fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmChasFanPresTrap | 1.3.6.1.4.1.5.1.1.5.6.35 | ||
| Trap indicating the status of the chasis fan. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmChasFanIndTrap | 1.3.6.1.4.1.5.1.1.5.6.36 | ||
| Trap indicating the status of the chasis fan whether it failed or recovered. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmLowMemTrap | 1.3.6.1.4.1.5.1.1.5.6.37 | ||
| This indicates very clearly that the Memory is very low and the admin has to do some dagnostics and take a quick action on the various memory critical issues for instance like trap log size etc., SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 32 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accMemBlkEntTotal | |||
| accMemBlkEntInUse | |||
| accTrapLogSeverityType | |||
| accTrapLogSeqNum | |||
| accRmLanDiagsTrap | 1.3.6.1.4.1.5.1.1.5.6.38 | ||
| When the diagnostics on the particular LAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 6 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accTrapLogSeqNum | |||
| accRmWanDiagsTrap | 1.3.6.1.4.1.5.1.1.5.6.39 | ||
| When the diagnostics on the particular WAN slot fails this trap is generated. Indicating that there is some problem with that interface. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 6 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accTrapLogSeqNum | |||
| accRmCardDiagsTrap | 1.3.6.1.4.1.5.1.1.5.6.40 | ||
| When the diagnostics on the particular CARD slot fails this trap is generated. Indicating that there is some problem with that CARD. SEVERITY-DEFAULT: Critical EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 6 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accCardSlotNum | |||
| accTrapLogSeqNum | |||
| accRmResetTrap | 1.3.6.1.4.1.5.1.1.5.6.41 | ||
| This trap is to prompt the admin to reset the router as he would have changed some settings and they will be effective only after a reset for example change/deletion in static routing entry on a particular interface. SEVERITY-DEFAULT: Major EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accMemEMEStatus | |||
| accTrapLogSeqNum | |||
| accRmIdbTrap | 1.3.6.1.4.1.5.1.1.5.6.42 | ||
| SEVERITY-DEFAULT: Indeterminate EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 0 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| accTrapLogSeqNum | |||
| accRmLdngElemManTrap | 1.3.6.1.4.1.5.1.1.5.6.43 | ||
| Browser loading Element Manager at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| tcpConnRemAddress | |||
| accTrapLogSeqNum | |||
| accRmInterFileJavaManTrap | 1.3.6.1.4.1.5.1.1.5.6.44 | ||
| Intermediate file sent to Java Manager %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| tcpConnRemAddress | |||
| accTrapLogSeqNum | |||
| accRmBrowLdngSetupWizTrap | 1.3.6.1.4.1.5.1.1.5.6.45 | ||
| Browser loading Java Setup Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| tcpConnRemAddress | |||
| accTrapLogSeqNum | |||
| accRmConfWizLddTrap | 1.3.6.1.4.1.5.1.1.5.6.46 | ||
| Configuration Wizard is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| tcpConnRemAddress | |||
| accTrapLogSeqNum | |||
| accRmPriConfScrTrap | 1.3.6.1.4.1.5.1.1.5.6.47 | ||
| Primary config script sent to Configuration Wizard at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| tcpConnRemAddress | |||
| accTrapLogSeqNum | |||
| accRmInstAccAppLddTrap | 1.3.6.1.4.1.5.1.1.5.6.48 | ||
| Instant Access applet is being loaded by the browser at %s SEVERITY-DEFAULT: Warning EVENTTYPE-DEFAULT: 10 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 7 | |||
| TRAP-TYPE | |||
| accCardSlotTrapMsg | |||
| tcpConnRemAddress | |||
| accTrapLogSeqNum | |||
| AccSlotEntry | |||
| SEQUENCE | |||
| OCTET STRING as accSlotLastChangeY2K | |||
| Counter as accSlotInPkts | |||
| Counter as accSlotOutPkts | |||
| Counter as accSlotNumChanges | |||
| INTEGER as accSlotProtocol | |||
| INTEGER as accSlotClockMode | |||
| INTEGER as accSlotQueueMode | |||
| INTEGER as accSlotDialProcedure | |||
| INTEGER as accSlotResyncMode | |||
| INTEGER as accSlotCompressMode | |||
| INTEGER as accSlotCompressV42bisP1 | |||
| INTEGER as accSlotCompressV42bisP2 | |||
| INTEGER as accSlotCompressDcs221P1 | |||
| INTEGER as accSlotSevereCongPct | |||
| DisplayString as accSlotDialAddress | |||
| INTEGER as accSlotCompressRevision | |||
| INTEGER as accSlotCompressMaxStreams | |||
| INTEGER as accSlotCompressMessageLevel | |||
| INTEGER as accSlotIfType | |||
| INTEGER as accSlotE1FrameMode | |||
| AccCardSlotEntry | |||
| SEQUENCE | |||
| INTEGER as accCardSlotNum | |||
| INTEGER as accCardSlotType | |||
| DisplayString as accCardSlotRevNum | |||
| DisplayString as accCardSlotSerNum | |||
| DisplayString as accCardSlotPortCnf | |||
| INTEGER as accCardSlotAdminState | |||
| INTEGER as accCardSlotOperState | |||
| INTEGER as accCardSlotIndex | |||
| INTEGER as accCardSlotNum11Slot | |||
| AccCardInterfaceEntry | |||
| SEQUENCE | |||
| INTEGER as accCardInterfaceNum | |||
| INTEGER as accCardInterfaceType | |||
| INTEGER as accCardInterfaceSlotNum | |||
| INTEGER as accCardInterfaceIndex | |||
| AccCardCircuitEntry | |||
| SEQUENCE | |||
| INTEGER as accCardCircuitNum | |||
| INTEGER as accCardCircuitSlotNum | |||
| INTEGER as accCardCircuitInterfaceNum | |||
| INTEGER as accCardCircuitIndex | |||