AISLC1-MIB
File:
AISLC1-MIB.mib (12712 bytes)
Imported modules
Imported symbols
Defined Objects
| aii |
1.3.6.1.4.1.539 |
| OBJECT IDENTIFIER |
|
|
|
| ai192 |
1.3.6.1.4.1.539.2.192 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver7 |
1.3.6.1.4.1.539.2.192.7 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver70 |
1.3.6.1.4.1.539.2.192.7.0 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver708 |
1.3.6.1.4.1.539.2.192.7.0.8 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver709 |
1.3.6.1.4.1.539.2.192.7.0.9 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver71 |
1.3.6.1.4.1.539.2.192.7.1 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver710 |
1.3.6.1.4.1.539.2.192.7.1.0 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver711 |
1.3.6.1.4.1.539.2.192.7.1.1 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver72 |
1.3.6.1.4.1.539.2.192.7.2 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver720 |
1.3.6.1.4.1.539.2.192.7.2.0 |
| OBJECT IDENTIFIER |
|
|
|
| ai192Ver77 |
1.3.6.1.4.1.539.2.192.7.7 |
| OBJECT IDENTIFIER |
|
|
|
| ai196 |
1.3.6.1.4.1.539.2.196 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver7 |
1.3.6.1.4.1.539.2.196.7 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver70 |
1.3.6.1.4.1.539.2.196.7.0 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver708 |
1.3.6.1.4.1.539.2.196.7.0.8 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver709 |
1.3.6.1.4.1.539.2.196.7.0.9 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver71 |
1.3.6.1.4.1.539.2.196.7.1 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver710 |
1.3.6.1.4.1.539.2.196.7.1.0 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver711 |
1.3.6.1.4.1.539.2.196.7.1.1 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver72 |
1.3.6.1.4.1.539.2.196.7.2 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver720 |
1.3.6.1.4.1.539.2.196.7.2.0 |
| OBJECT IDENTIFIER |
|
|
|
| ai196Ver77 |
1.3.6.1.4.1.539.2.196.7.7 |
| OBJECT IDENTIFIER |
|
|
|
| aislc1AdminTrapsEnabled |
1.3.6.1.4.1.539.11.1.2 |
| Determines whether the SLC sends SNMP Trap PDUs. If the active CLC in the AISwitch chassis with the SLC is not SNMP capable, this object cannot be set to the value on(1). |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
on(1), off(2) |
|
| aislc1AdminTrapTimer |
1.3.6.1.4.1.539.11.1.3 |
| After a trap is generated, a timer is started. If the event that generated the trap occurs while the timer is running, no trap will be generated for the event. The value of this object is the duration of the timer in seconds. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..'ffff'h |
|
| aislc1OperLastMsgText |
1.3.6.1.4.1.539.11.1.4 |
| Contains the message text of the last log message that was sent by the SLC (or would have been sent, if log message transmission is disabled. |
| OBJECT-TYPE |
|
|
|
| |
DisplayString |
SIZE(0..245) |
|
| aislc1OperLastMsgNum |
1.3.6.1.4.1.539.11.1.5 |
| Contains the message number of the last log message that was sent by the SLC (or would have been sent, if log message transmission is disabled. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..'ffff'h |
|
| aislc1OperCrashCode |
1.3.6.1.4.1.539.11.1.6 |
| Contains a crash cause code. This object is for use as a varbind in TRAP PDUs only. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
crashbus('01'h), crashvector('09'h), crashx25('a0'h), crashstack('a2'h), crashmain('a3'h), crashchecksum('a4'h), crashinit('a5'h), crashreboot('a6'h), crashtimer('a7'h), crashstopped('a8'h), crashbadzero('a9'h), crashmemfail('aa'h), crashrxfifo('ab'h), crashscc('ac'h) |
|
| aislc1OperNumEventsSinceLastTrap |
1.3.6.1.4.1.539.11.1.7 |
| The number of times this trap was discarded because the aislcAdminTrapTimer had not yet expired since the last time the event which generated the trap occured. This object is for use as a varbind in TRAP PDUs only. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..'ffff'h |
|
| aislc1StatTotalVCs |
1.3.6.1.4.1.539.11.1.11 |
| The total number of Virtual Connection structures allocated on the SLC. |
| OBJECT-TYPE |
|
|
|
| |
INTEGER |
0..'ffff'h |
|
| aislc1StatFErrFifoInIsr |
1.3.6.1.4.1.539.11.1.15 |
| Number of RxFIFO half-full ISR interrupts which occurred. This is not always an error, but may be indicative of a heavy load on the X.25 software. |
| OBJECT-TYPE |
|
|
|
| |
Counter32 |
|
|
| aislc1StatErrFifoInFull |
1.3.6.1.4.1.539.11.1.16 |
| Number of times the input FIFO was detected as full. This means that data has probably been lost, due to the inability of the X.25 software to keep pace with the RxFIFO. |
| OBJECT-TYPE |
|
|
|
| |
Counter32 |
|
|
| aislc1StatErrFifoInPort |
1.3.6.1.4.1.539.11.1.17 |
| Number of times a bad port number has been received through the FIFO. This is probably indicative of a hardware failure, or perhaps a software problem in the CLC code. |
| OBJECT-TYPE |
|
|
|
| |
Counter32 |
|
|
| aislc1StatErrFifoOutFull |
1.3.6.1.4.1.539.11.1.19 |
| Number of times the output FIFO was detected as full. This may be an indication of a hardware fault, or a breakdown in communications between the X.25 software and CLC regarding the status of a connection(i.e., if the CLC breaks a connection while the X.25 software is still using it, a TxFIFO full will definitely result). |
| OBJECT-TYPE |
|
|
|
| |
Counter32 |
|
|
| aislc1StatErrWinInDisc |
1.3.6.1.4.1.539.11.1.23 |
| Number of bad disconnection transactions from the CLC via the window. Note that this counter will probably be incremented if calls are disconnected following a link outage, it is not necessarily indicative of a serious problem. |
| OBJECT-TYPE |
|
|
|
| |
Counter32 |
|
|