| SNMPv2-SMI | SNMPv2-TC |
| MODULE-IDENTITY | OBJECT-TYPE | enterprises |
| TruthValue | DisplayString |
| aii | 1.3.6.1.4.1.539 | ||
| OBJECT IDENTIFIER | |||
| aiSLCAnalog | 1.3.6.1.4.1.539.28 | ||
| MIB module for SLCs with analog input points. | |||
| MODULE-IDENTITY | |||
| aiSLCAnalogInputTable | 1.3.6.1.4.1.539.28.1 | ||
| Table of analog inputs points indexed by point number. Includes description, configuration and status information. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AISLCAnalogInputEntry | |||
| aiSLCAnalogInputEntry | 1.3.6.1.4.1.539.28.1.1 | ||
| Entry of aiSLCAnalogInputTable. | |||
| OBJECT-TYPE | |||
| AISLCAnalogInputEntry | |||
| aislcainPointNumber | 1.3.6.1.4.1.539.28.1.1.1 | ||
| Input point number to which this table row applies. | |||
| OBJECT-TYPE | |||
| PositiveInteger | |||
| aislcainScanningEnabled | 1.3.6.1.4.1.539.28.1.1.2 | ||
| Enable or disable scanning of the input. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2) | ||
| aislcainDescription | 1.3.6.1.4.1.539.28.1.1.3 | ||
| Textual description of the point. Maximum length is 80 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..80) | ||
| aislcainTrapEnable | 1.3.6.1.4.1.539.28.1.1.4 | ||
| Enable or disable alarm traps. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2) | ||
| aislcainNormalStateTrap | 1.3.6.1.4.1.539.28.1.1.5 | ||
| If enabled, transitions from an alarm state to the normal state will generate an SNMP trap or TL1 message. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2) | ||
| aislcainHighAlarmSeverity | 1.3.6.1.4.1.539.28.1.1.6 | ||
| Severity of the point's alarm state, or notReported(5) if the point does not generate an alarm. | |||
| OBJECT-TYPE | |||
| INTEGER | critical(1), major(2), minor(3), info(4), notReported(5) | ||
| aislcainHighAlarmStateText | 1.3.6.1.4.1.539.28.1.1.7 | ||
| Textual description of the point's alarm state. Maximum length is 80 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..80) | ||
| aislcainLowAlarmSeverity | 1.3.6.1.4.1.539.28.1.1.8 | ||
| Severity of the point's alarm state, or notReported(5) if the point does not generate an alarm. | |||
| OBJECT-TYPE | |||
| INTEGER | critical(1), major(2), minor(3), info(4), notReported(5) | ||
| aislcainLowAlarmStateText | 1.3.6.1.4.1.539.28.1.1.9 | ||
| Textual description of the point's alarm state. Maximum length is 80 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..80) | ||
| aislcainNormalStateText | 1.3.6.1.4.1.539.28.1.1.10 | ||
| Textual description of the point's normal state. Maximum length is 80 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..80) | ||
| aislcainUserUnits | 1.3.6.1.4.1.539.28.1.1.11 | ||
| The user-defined units for this input (e.g. degC, degF, etc.). | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..16) | ||
| aislcainMinInputmA | 1.3.6.1.4.1.539.28.1.1.12 | ||
| The current in mA corresponding to the minimum input in user-defined units. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainMinInputuu | 1.3.6.1.4.1.539.28.1.1.13 | ||
| The minimum value in user-defined units corresponding to the minimum input in mA. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainMaxInputmA | 1.3.6.1.4.1.539.28.1.1.14 | ||
| The current in mA corresponding to the maximum input in user-defined units. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainMaxInputuu | 1.3.6.1.4.1.539.28.1.1.15 | ||
| The maximum value in user-defined units corresponding to the maximum input in mA. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainHighLimitScan | 1.3.6.1.4.1.539.28.1.1.16 | ||
| If enabled, the high limit threshold will be checked when the input is scanned. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2) | ||
| aislcainHighAlarmThresholduu | 1.3.6.1.4.1.539.28.1.1.17 | ||
| The high alarm level in user-defined units. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainHighAlarmThresholdIntervaluu | 1.3.6.1.4.1.539.28.1.1.18 | ||
| The high alarm level threshold interval in user-defined units. When the high alarm is active, each time the input rises another interval higher, a new alarm is sent. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainHighAlarmMinPeriod | 1.3.6.1.4.1.539.28.1.1.19 | ||
| The minimum number of seconds the input(s) should be energized when the input exceeds the high alarm threshold. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..600 | ||
| aislcainHighAlarmHysteresisuu | 1.3.6.1.4.1.539.28.1.1.20 | ||
| The amount by which the input must drop below the High Alarm Threshold before the High Alarm will be cleared. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainLowLimitScan | 1.3.6.1.4.1.539.28.1.1.21 | ||
| If enabled, the low limit threshold will be checked when the input is scanned. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2) | ||
| aislcainLowAlarmThresholduu | 1.3.6.1.4.1.539.28.1.1.22 | ||
| The low alarm level in user-defined units. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainLowAlarmThresholdIntervaluu | 1.3.6.1.4.1.539.28.1.1.23 | ||
| The low alarm level threshold interval in user-defined units. When the low alarm is active, each time the input drops another interval lower, a new alarm is sent. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainLowAlarmMinPeriod | 1.3.6.1.4.1.539.28.1.1.24 | ||
| The minimum number of seconds the input(s) should be energized when the input falls below the low alarm threshold. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..600 | ||
| aislcainLowAlarmHysteresisuu | 1.3.6.1.4.1.539.28.1.1.25 | ||
| The amount by which the input must rise above the Low Alarm Threshold before the Low Alarm will be cleared. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainCurrentValueuu | 1.3.6.1.4.1.539.28.1.1.26 | ||
| The current input value in user-defined units. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..16) | ||
| aislcainCurrentValuemA | 1.3.6.1.4.1.539.28.1.1.27 | ||
| The current input value in mA. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| aislcainLastChangeTime | 1.3.6.1.4.1.539.28.1.1.28 | ||
| Textural representation of the time of the most recent output change. 24-hour format YYYY-MM-DD HH:MM:SS. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(19..23) | ||
| aislcaintl1AccessID | 1.3.6.1.4.1.539.28.1.1.29 | ||
| Unique TL1 access identifier for this point. Maximum length is 22 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..22) | ||
| aislcaintl1Provisioned | 1.3.6.1.4.1.539.28.1.1.30 | ||
| Enable TL1 management of this point. | |||
| OBJECT-TYPE | |||
| TruthValue | |||
| aislcaintl1AccessIDType | 1.3.6.1.4.1.539.28.1.1.31 | ||
| Identifies the point as either an equipment(1) alarm condition or an environmental(2) alarm. | |||
| OBJECT-TYPE | |||
| INTEGER | equipment(1), environmental(2) | ||
| aislcaintl1HighAlarmType | 1.3.6.1.4.1.539.28.1.1.32 | ||
| String indicating the type of alarm, used only when aislcaintl1AccessIDType is environmental(2). Maximum length is 10 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..10) | ||
| aislcaintl1HighAlarmMessage | 1.3.6.1.4.1.539.28.1.1.33 | ||
| Textual description of the alarm, used only when aislcaintl1AccessIDType is environmental(2). Maximum length is 40 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..40) | ||
| aislcaintl1LowAlarmType | 1.3.6.1.4.1.539.28.1.1.34 | ||
| String indicating the type of alarm, used only when aislcaintl1AccessIDType is environmental(2). Maximum length is 10 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..10) | ||
| aislcaintl1LowAlarmMessage | 1.3.6.1.4.1.539.28.1.1.35 | ||
| Textual description of the alarm, used only when aislcaintl1AccessIDType is environmental(2). Maximum length is 40 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..40) | ||
| aislcaintl1HighAlarmNotificationCode | 1.3.6.1.4.1.539.28.1.1.36 | ||
| Severity of the point's alarm state. | |||
| OBJECT-TYPE | |||
| INTEGER | critical(1), major(2), minor(3) | ||
| aislcaintl1HighAlarmServiceAffecting | 1.3.6.1.4.1.539.28.1.1.37 | ||
| Indicates whether or not the alarm affects the functioning of the equipment. This is only meaningful when aislcaintl1AccessIDType is equipment(1). | |||
| OBJECT-TYPE | |||
| INTEGER | serviceAffecting(1), notServiceAffecting(2) | ||
| aislcaintl1HighAlarmConditionType | 1.3.6.1.4.1.539.28.1.1.38 | ||
| String indicating the type of alarm condition, used only when aislcaintl1AccessIDType is equipment(1). Maximum length is 20 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| aislcaintl1HighAlarmConditionDesc | 1.3.6.1.4.1.539.28.1.1.39 | ||
| Textual description of the alarm condition, used only when aislcaintl1AccessIDType is equipment(1). Maximum length is 64 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..64) | ||
| aislcaintl1LowAlarmNotificationCode | 1.3.6.1.4.1.539.28.1.1.40 | ||
| Severity of the point's alarm state. | |||
| OBJECT-TYPE | |||
| INTEGER | critical(1), major(2), minor(3) | ||
| aislcaintl1LowAlarmServiceAffecting | 1.3.6.1.4.1.539.28.1.1.41 | ||
| Indicates whether or not the alarm affects the functioning of the equipment. This is only meaningful when aislcaintl1AccessIDType is equipment(1). | |||
| OBJECT-TYPE | |||
| INTEGER | serviceAffecting(1), notServiceAffecting(2) | ||
| aislcaintl1LowAlarmConditionType | 1.3.6.1.4.1.539.28.1.1.42 | ||
| String indicating the type of alarm condition, used only when aislcaintl1AccessIDType is equipment(1). Maximum length is 20 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| aislcaintl1LowAlarmConditionDesc | 1.3.6.1.4.1.539.28.1.1.43 | ||
| Textual description of the alarm condition, used only when aislcaintl1AccessIDType is equipment(1). Maximum length is 64 characters. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..64) | ||
| aislcainAnalogStatus | 1.3.6.1.4.1.539.28.1.1.44 | ||
| The current alarm status of the analog input. | |||
| OBJECT-TYPE | |||
| INTEGER | normal(1), highLimitExceeded(2), lowLimitExceeded(3), lossOfSignal(4), saturated(5) | ||
| aislcainCurrentStateText | 1.3.6.1.4.1.539.28.1.1.45 | ||
| Textual description of the point's current state. This is either aislcainNormalStateText or aislcainAlarmStateText. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..80) | ||
| aislcainAnalogAlarmState | 1.3.6.1.4.1.539.28.1.1.46 | ||
| The point's current alarm state, or normal(5). | |||
| OBJECT-TYPE | |||
| INTEGER | critical(1), major(2), minor(3), info(4), normal(5) | ||
| PositiveInteger | |||
| INTEGER | 1..2147483647 | ||
| NonNegativeInteger | |||
| INTEGER | 0..2147483647 | ||
| AISLCAnalogInputEntry | |||
| SEQUENCE | |||
| PositiveInteger as aislcainPointNumber | |||
| INTEGER as aislcainScanningEnabled | |||
| DisplayString as aislcainDescription | |||
| INTEGER as aislcainTrapEnable | |||
| INTEGER as aislcainNormalStateTrap | |||
| INTEGER as aislcainHighAlarmSeverity | |||
| DisplayString as aislcainHighAlarmStateText | |||
| INTEGER as aislcainLowAlarmSeverity | |||
| DisplayString as aislcainLowAlarmStateText | |||
| DisplayString as aislcainNormalStateText | |||
| DisplayString as aislcainUserUnits | |||
| DisplayString as aislcainMinInputmA | |||
| DisplayString as aislcainMinInputuu | |||
| DisplayString as aislcainMaxInputmA | |||
| DisplayString as aislcainMaxInputuu | |||
| INTEGER as aislcainHighLimitScan | |||
| DisplayString as aislcainHighAlarmThresholduu | |||
| DisplayString as aislcainHighAlarmThresholdIntervaluu | |||
| INTEGER as aislcainHighAlarmMinPeriod | |||
| DisplayString as aislcainHighAlarmHysteresisuu | |||
| INTEGER as aislcainLowLimitScan | |||
| DisplayString as aislcainLowAlarmThresholduu | |||
| DisplayString as aislcainLowAlarmThresholdIntervaluu | |||
| INTEGER as aislcainLowAlarmMinPeriod | |||
| DisplayString as aislcainLowAlarmHysteresisuu | |||
| DisplayString as aislcainCurrentValueuu | |||
| DisplayString as aislcainCurrentValuemA | |||
| DisplayString as aislcainLastChangeTime | |||
| DisplayString as aislcaintl1AccessID | |||
| TruthValue as aislcaintl1Provisioned | |||
| INTEGER as aislcaintl1AccessIDType | |||
| DisplayString as aislcaintl1HighAlarmType | |||
| DisplayString as aislcaintl1HighAlarmMessage | |||
| DisplayString as aislcaintl1LowAlarmType | |||
| DisplayString as aislcaintl1LowAlarmMessage | |||
| DisplayString as aislcaintl1HighAlarmNotificationCode | |||
| INTEGER as aislcaintl1HighAlarmServiceAffecting | |||
| DisplayString as aislcaintl1HighAlarmConditionType | |||
| DisplayString as aislcaintl1HighAlarmConditionDesc | |||
| DisplayString as aislcaintl1LowAlarmNotificationCode | |||
| INTEGER as aislcaintl1LowAlarmServiceAffecting | |||
| DisplayString as aislcaintl1LowAlarmConditionType | |||
| DisplayString as aislcaintl1LowAlarmConditionDesc | |||
| INTEGER as aislcainAnalogStatus | |||
| DisplayString as aislcainCurrentStateText | |||
| INTEGER as aislcainAnalogAlarmState | |||