AIX1-MIB

File: AIX1-MIB.mib (81226 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI

Imported symbols

DisplayString MODULE-IDENTITY OBJECT-TYPE
Counter32 Integer32 enterprises

Defined Objects

aii 1.3.6.1.4.1.539
OBJECT IDENTIFIER    

aiSystemOID 1.3.6.1.4.1.539.2
OBJECT IDENTIFIER    

ai192 1.3.6.1.4.1.539.2.192
OBJECT IDENTIFIER    

ai192Ver7 1.3.6.1.4.1.539.2.192.7
OBJECT IDENTIFIER    

ai192Ver70 1.3.6.1.4.1.539.2.192.7.0
OBJECT IDENTIFIER    

ai192Ver708 1.3.6.1.4.1.539.2.192.7.0.8
OBJECT IDENTIFIER    

ai192Ver709 1.3.6.1.4.1.539.2.192.7.0.9
OBJECT IDENTIFIER    

ai192Ver71 1.3.6.1.4.1.539.2.192.7.1
OBJECT IDENTIFIER    

ai192Ver710 1.3.6.1.4.1.539.2.192.7.1.0
OBJECT IDENTIFIER    

ai192Ver711 1.3.6.1.4.1.539.2.192.7.1.1
OBJECT IDENTIFIER    

ai192Ver72 1.3.6.1.4.1.539.2.192.7.2
OBJECT IDENTIFIER    

ai192Ver720 1.3.6.1.4.1.539.2.192.7.2.0
OBJECT IDENTIFIER    

ai192Ver721 1.3.6.1.4.1.539.2.192.7.2.1
OBJECT IDENTIFIER    

ai192Ver77 1.3.6.1.4.1.539.2.192.7.7
OBJECT IDENTIFIER    

ai196 1.3.6.1.4.1.539.2.196
OBJECT IDENTIFIER    

ai196Ver7 1.3.6.1.4.1.539.2.196.7
OBJECT IDENTIFIER    

ai196Ver70 1.3.6.1.4.1.539.2.196.7.0
OBJECT IDENTIFIER    

ai196Ver708 1.3.6.1.4.1.539.2.196.7.0.8
OBJECT IDENTIFIER    

ai196Ver709 1.3.6.1.4.1.539.2.196.7.0.9
OBJECT IDENTIFIER    

ai196Ver71 1.3.6.1.4.1.539.2.196.7.1
OBJECT IDENTIFIER    

ai196Ver710 1.3.6.1.4.1.539.2.196.7.1.0
OBJECT IDENTIFIER    

ai196Ver711 1.3.6.1.4.1.539.2.196.7.1.1
OBJECT IDENTIFIER    

ai196Ver72 1.3.6.1.4.1.539.2.196.7.2
OBJECT IDENTIFIER    

ai196Ver720 1.3.6.1.4.1.539.2.196.7.2.0
OBJECT IDENTIFIER    

ai196Ver721 1.3.6.1.4.1.539.2.196.7.2.1
OBJECT IDENTIFIER    

ai196Ver77 1.3.6.1.4.1.539.2.196.7.7
OBJECT IDENTIFIER    

aiX1 1.3.6.1.4.1.539.12
OBJECT IDENTIFIER    

aiX1System 1.3.6.1.4.1.539.12.1
OBJECT IDENTIFIER    

aix1AdminGbufXoffThreshold 1.3.6.1.4.1.539.12.1.1
The configured XOFF global flow control threshold. If zero and if aix1AdminGbufRecovThreshold is zero, the global flow control mechanism is disabled.
OBJECT-TYPE    
  INTEGER 0..'ffff'h  

aix1AdminGbufRecovThreshold 1.3.6.1.4.1.539.12.1.2
The configured recovery global flow control threshold. If zero and if aix1AdminGbufXoffThreshold is zero, the global flow control mechanism is disabled.
OBJECT-TYPE    
  INTEGER 0..'ffff'h  

aix1AdminRollover 1.3.6.1.4.1.539.12.1.3
This object has been depricated and remains in the MIB for backward compatibility.
OBJECT-TYPE    
  INTEGER ready(1), roll(2)  

aix1Bx25AdminCallDown 1.3.6.1.4.1.539.12.1.4
If set to off(2), an active BX.25 link will stay up after all calls are disconnected. If set to on(1), an active BX.25 link will drop and go into DMLOCK (see aix1Bx25AdminDMlock below) when all the link's backplane connections are terminated. This object is meaningful only when aix1ApplOperLinkMode is set to passive(2) on a given packet layer entity.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1Bx25AdminDMlock 1.3.6.1.4.1.539.12.1.5
The number of seconds to wait after a BX.25 passive link has gone inactive before allowing an outgoing call to attempt to bring up the link. Any outgoing call attempts will be rejected until the DMLOCK timer expires and the passive link returns to the standby mode. This object is meaningful only when aix1ApplOperLinkMode is set to passive(2) on a given packet layer entity.
OBJECT-TYPE    
  INTEGER 25..'ffffffff'h  

aix1Bx25AdminLinkUp 1.3.6.1.4.1.539.12.1.6
The number of seconds to wait for a passive link to become active. This object is meaningful only when aix1ApplOperLinkMode is set to passive(2) on a given packet layer entity.
OBJECT-TYPE    
  INTEGER 5..'ffffffff'h  

aix1StatErrX25InData 1.3.6.1.4.1.539.12.1.7
Number of data bytes from X.25 which were lost due to buffer failures.
OBJECT-TYPE    
  Counter32  

aix1StatErrX25OutData 1.3.6.1.4.1.539.12.1.8
Number of data bytes from the FIFO which were discarded due to buffer failures.
OBJECT-TYPE    
  Counter32  

aix1StatErrX25OutPkt 1.3.6.1.4.1.539.12.1.9
Number of messages from X.25 to GCOM which were lost due to some kind of resource failure in the GCOM library.
OBJECT-TYPE    
  Counter32  

aix1StatErrX25OutChoked 1.3.6.1.4.1.539.12.1.10
Number of times a port has received a flow control stop message from GCOM(or perhaps from X.25), and thus entered the Choked state. This may not be indicative of a serious problem, but may also mean that data has been lost.
OBJECT-TYPE    
  Counter32  

aix1StatErrPlogCount 1.3.6.1.4.1.539.12.1.11
Number of times an internal error routine has been called due to unexpected packets received from GCOM ( or X.25).
OBJECT-TYPE    
  Counter32  

aix1StatErrGfctlXoffs 1.3.6.1.4.1.539.12.1.12
Number of times the global flow control mechanism attempted to back pressure data flow from the backplane.
OBJECT-TYPE    
  Counter32  

aix1StatErrGfctlDiscards 1.3.6.1.4.1.539.12.1.13
Number of times the global flow control mechanism has detected a buffer level so low that it discarded data received from the backplane.
OBJECT-TYPE    
  Counter32  

aix1StatErrUwteBadTrans 1.3.6.1.4.1.539.12.1.14
Number of unified window transactions with bad transaction codes received from CLC or a remote SLC. If this counter is non-zero, it indicated the presence of incompatible versions of firmware on the SLC and CLC, or a bug in either the SLC or CLC firmware.
OBJECT-TYPE    
  Counter32  

aix1StatErrUwteBadFlds 1.3.6.1.4.1.539.12.1.15
Number of invalid fields received in unified window transactions. If this counter is non-zero, it indicates the presence of incompatible versions or a bug in either the SLC or CLC firmware.
OBJECT-TYPE    
  Counter32  

aix1StatErrUwteMissingFlds 1.3.6.1.4.1.539.12.1.16
Number of required fields absent from received unified window transactions. If this counter is non-zero, it indicates the presence of incompatible versions or a bug in either the SLC or CLC firmware.
OBJECT-TYPE    
  Counter32  

aix1StatErrLogOutLost 1.3.6.1.4.1.539.12.1.17
Number of outbound log messages discarded to avoid flooding the log. This arises because the SLC is attempting to generate log messages too frequently on a particular TDS or globally. When this occurs, the SLC will discard the log message and increment the counter. This is not a serious error, and typically occurs during periods of intense, repetitive logging activity.
OBJECT-TYPE    
  Counter32  

aix1StatErrVcMuxErrs 1.3.6.1.4.1.539.12.1.18
Number of serious multiplexing errors which have occurred. Such an error generally involves an impossible value in an internal header or receipt of a message on the wrong internal channel.
OBJECT-TYPE    
  Counter32  

aix1StatErrEmptyPktsRcv 1.3.6.1.4.1.539.12.1.19
Number of empty data packets received from the network.
OBJECT-TYPE    
  Counter32  

aix1StatInCharsPerSec80s 1.3.6.1.4.1.539.12.1.20
The average number of data characters (characters in the data field of X.25 data packets) received from the network per second over the last 80 seconds.
OBJECT-TYPE    
  Counter32  

aix1StatOutCharsPerSec80s 1.3.6.1.4.1.539.12.1.21
The average number of data characters (characters in the data field of X.25 data packets) transmitted to the network per second over the last 80 seconds.
OBJECT-TYPE    
  Counter32  

aiX1Appl 1.3.6.1.4.1.539.12.2
OBJECT IDENTIFIER    

aix1ApplAdminTable 1.3.6.1.4.1.539.12.2.1
The table of administrative elements which apply to an individual X.25 link above the packet layer.
OBJECT-TYPE    
  SEQUENCE OF  
    ApplAdminEntry

aix1ApplAdminEntry 1.3.6.1.4.1.539.12.2.1.1
The addressing information for one of this X.25 link's administrative objects.
OBJECT-TYPE    
  ApplAdminEntry  

aix1ApplAdminIndex 1.3.6.1.4.1.539.12.2.1.1.1
The ifIndex value of the packet layer entity associated with these application level objects.
OBJECT-TYPE    
  IfIndexType  

aix1ApplAdminLinkStart 1.3.6.1.4.1.539.12.2.1.1.2
Start or stop a link that's enabled by the standard MIB link status objects. If the link is not enabled by the standard MIB objects, a write to this object will have no effect. Stopping a link by writing to this object does not free significant resources, it just stops activity on the link.
OBJECT-TYPE    
  INTEGER started(1), stopped(2)  

aix1ApplAdminLinkMode 1.3.6.1.4.1.539.12.2.1.1.3
Determines whether link behaves as a normal X.25 link or a BX.25-style passive link. This is the most recently configured value of this attribute, and may not yet have taken effect. The current operating value is available as aix1ApplOperLinkMode.
OBJECT-TYPE    
  INTEGER normal(1), passive(2)  

aix1ApplAdminResetErrs 1.3.6.1.4.1.539.12.2.1.1.4
Writing the value resetCounters(2) to this object resets the per-link level 1 error counters. No other writes are accepted. They are aix1PhysStatRxCRCErrors, aix1PhysStatRxAborts, aix1PhysStatRxOverruns, aix1PhysStatTxAborts, aix1PhysStatTxUnderruns.
OBJECT-TYPE    
  INTEGER ready(1), resetCounters(2)  

aix1ApplAdminXONXOFFProto 1.3.6.1.4.1.539.12.2.1.1.5
Determines whether XON/XOFF protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminNMAProto 1.3.6.1.4.1.539.12.2.1.1.6
Determines whether NMA protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminOPSINEProto 1.3.6.1.4.1.539.12.2.1.1.7
Determines whether OPSINE protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminTL1Proto 1.3.6.1.4.1.539.12.2.1.1.8
Determines whether TL1 protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplAdminLinkDescription 1.3.6.1.4.1.539.12.2.1.1.9
A descriptive string associated with this link. This provides a place for the agent to supply any descriptive information about the use or owner of the link. A zero length value indicates that the agent doesn't have any additional information.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

aix1ApplAdminLinkConnectionMode 1.3.6.1.4.1.539.12.2.1.1.10
Connect or disconnect a link that's enabled by the standard MIB linmk status objects. If the link is not enabled by the standard MIB objects, a write to this object will have no effect. Disconnecting a link by writing to this object does not free any resources, it marks the link as not connected, so that the link will not cause a level 4 (LINKDOWN) alarm to be generated.
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(4)  

aix1ApplOperTable 1.3.6.1.4.1.539.12.2.2
The table of operational elements which apply to an individual X.25 link above the packet layer.
OBJECT-TYPE    
  SEQUENCE OF  
    ApplOperEntry

aix1ApplOperEntry 1.3.6.1.4.1.539.12.2.2.1
The addressing information for one of this X.25 link's operational objects.
OBJECT-TYPE    
  ApplOperEntry  

aix1ApplOperIndex 1.3.6.1.4.1.539.12.2.2.1.1
The ifIndex value of the packet level associated with these application level objects.
OBJECT-TYPE    
  IfIndexType  

aix1ApplOperLinkMode 1.3.6.1.4.1.539.12.2.2.1.2
Determines whether link behaves as a normal X.25 link or a BX.25-style passive link. This is the mandatory operating value of this attribute. The most recently configured value is available as aix1ApplAdminLinkMode.
OBJECT-TYPE    
  INTEGER normal(1), passive(2)  

aix1ApplOperXONXOFFProto 1.3.6.1.4.1.539.12.2.2.1.3
Determines whether XON/XOFF protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperNMAProto 1.3.6.1.4.1.539.12.2.2.1.4
Determines whether NMA protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperOPSINEProto 1.3.6.1.4.1.539.12.2.2.1.6
Determines whether OPSINE protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperTL1Proto 1.3.6.1.4.1.539.12.2.2.1.7
Determines whether TL1 protocol processing is in effect by default on all virtual circuits on the link.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aix1ApplOperLinkDescription 1.3.6.1.4.1.539.12.2.2.1.8
A descriptive string associated with this link. This provides a place for the agent to supply any descriptive information about the use or owner of the link. A zero length value indicates that the agent doesn't have any additional information.
OBJECT-TYPE    
  DisplayString SIZE(0..50)  

aix1ApplOperLinkConnectionMode 1.3.6.1.4.1.539.12.2.2.1.9
Determines whether the link is currently disconnected, connected or has been reconnected after it was disconnected.
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), reconnected(3), disabled(4), linkdown(5), linkup(6)  

aiX1Pkt 1.3.6.1.4.1.539.12.3
OBJECT IDENTIFIER    

aix1PktAdminTable 1.3.6.1.4.1.539.12.3.1
The table of administrative elements which apply to an individual X.25 link at the packet layer.
OBJECT-TYPE    
  SEQUENCE OF  
    PktAdminEntry

aix1PktAdminEntry 1.3.6.1.4.1.539.12.3.1.1
The addressing information for one of this X.25 link's packet layer administrative objects.
OBJECT-TYPE    
  PktAdminEntry  

aix1PktAdminIndex 1.3.6.1.4.1.539.12.3.1.1.1
The ifIndex value of the packet layer entity associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1PktAdminConformanceMode 1.3.6.1.4.1.539.12.3.1.1.2
The configured conformance testing mode to which X.25's behavior will adhere. This value may not have taken effect. The value with which the SLC is currently operating is the value of aix1OperConformanceMode.
OBJECT-TYPE    
  INTEGER ccitt(1), ddn(2)  

aix1PktAdminDBit 1.3.6.1.4.1.539.12.3.1.1.3
Determines whether the packet level will allow the D-bit in call setup packets.
OBJECT-TYPE    
  INTEGER dbitNotAllowed(1), dbitAllowed(2)  

aix1PktAdminQBitMBit 1.3.6.1.4.1.539.12.3.1.1.4
Determines whether the packet level will check for consistency in the use of Q and M bits, i. e. that the value of the Q-bit is the same in every packet of an M-bit sequence.
OBJECT-TYPE    
  INTEGER noQMCheck(1), qmCheck(2)  

aix1PktAdminUseRejectPkts 1.3.6.1.4.1.539.12.3.1.1.5
Enables and disables the use of packet retransmission. If the packet level is acting as a DTE it will send a REJ packet in response to a data packet received out of sequence. If the packet level is acting as a DCE, it will accept a REJ packet and retransmit the requested data packet(s).
OBJECT-TYPE    
  INTEGER noPktRetrans(1), pktRetrans(2)  

aix1PktAdminSendInitialRestart 1.3.6.1.4.1.539.12.3.1.1.6
Enables and disables sending of an initial restart request packet when the link comes up.
OBJECT-TYPE    
  INTEGER initialRestart(1), noInitialRestart(2)  

aix1PktAdminStdsBody 1.3.6.1.4.1.539.12.3.1.1.7
Selects between ISO and CCITT packet level specifications.
OBJECT-TYPE    
  INTEGER ccittPktLvl(1), isoPktLvl(2)  

aix1PktAdminFacilChecking 1.3.6.1.4.1.539.12.3.1.1.8
Enables and disables packet level checking of the facilities field of call processing packets for validity.
OBJECT-TYPE    
  INTEGER checkFacils(1), noCheckFacils(2)  

aix1PktAdminUndefinedFacils 1.3.6.1.4.1.539.12.3.1.1.9
Enables and disables packet level allowing undefined facilities to appear in the facilities field of call processing packets.
OBJECT-TYPE    
  INTEGER noUndefFacils(1), undefFacils(2)  

aix1PktAdminDefMaxPktSize 1.3.6.1.4.1.539.12.3.1.1.10
The maximum packet size to use for all calls placed on this packet layer entity. If aix1PktAdminNegPktSize is set to negotiate(2), this will be the proposed value for calls placed on the packet level entitry.
OBJECT-TYPE    
  INTEGER pkt128(128), pkt256(256), pkt512(512), pkt1024(1024)  

aix1PktAdminDefWindowSize 1.3.6.1.4.1.539.12.3.1.1.11
The maximum packet level window size to use on this PLE. If aix1PktAdminNegWindowSize is set to negotiate(2), this will be the proposed value for calls placed on the packet layer entity.
OBJECT-TYPE    
  INTEGER 1..127  

aix1PktAdminNegMaxPktSize 1.3.6.1.4.1.539.12.3.1.1.12
Determines whether this PLE will originate calls which negotiate packet size.
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktAdminNegWindowSize 1.3.6.1.4.1.539.12.3.1.1.13
Determines whether this PLE will originate calls which negotiate window size.
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktAdminPacketizingTimer 1.3.6.1.4.1.539.12.3.1.1.14
The interval from the time of receipt of the first character from the TDM backplane to transmission of a block of characters to the X.25 protocol stack for transmission in a data packet to the network. In 100ths of a second. This value is not meaningful on backplane connections on which escape framing, TL1 packetizing, or programmable forwarding characters are active.
OBJECT-TYPE    
  INTEGER 0..255  

aix1PktAdminPVCOffset 1.3.6.1.4.1.539.12.3.1.1.15
Specifies an offset that gets added to the PVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktAdminSVCOffset 1.3.6.1.4.1.539.12.3.1.1.16
Specifies an offset that gets added to the SVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktOperTable 1.3.6.1.4.1.539.12.3.2
The table of operational elements which apply to an individual X.25 link at the packet layer.
OBJECT-TYPE    
  SEQUENCE OF  
    PktOperEntry

aix1PktOperEntry 1.3.6.1.4.1.539.12.3.2.1
The addressing information for one of this X.25 link's packet layer operational objects.
OBJECT-TYPE    
  PktOperEntry  

aix1PktOperIndex 1.3.6.1.4.1.539.12.3.2.1.1
The ifIndex value of the packet level associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1PktOperConformanceMode 1.3.6.1.4.1.539.12.3.2.1.2
The conformance testing mode to which X.25's behavior will adhere. This is the currently operational value.
OBJECT-TYPE    
  INTEGER ccitt(1), ddn(2)  

aix1PktOperDBit 1.3.6.1.4.1.539.12.3.2.1.3
Determines whether the packet level will allow the D-bit in call setup packets.
OBJECT-TYPE    
  INTEGER dbitNotAllowed(1), dbitAllowed(2)  

aix1PktOperQBitMBit 1.3.6.1.4.1.539.12.3.2.1.4
Determines whether the packet level will check for consistency in the use of Q and M bits, i. e. that the value of the Q-bit is the same in every packet of an M-bit sequence.
OBJECT-TYPE    
  INTEGER noQMCheck(1), qmCheck(2)  

aix1PktOperUseRejectPkts 1.3.6.1.4.1.539.12.3.2.1.5
Enables and disables the use of packet retransmission. If the packet level is acting as a DTE it will send a REJ packet in response to a data packet received out of sequence. If the packet level is acting as a DCE, it will accept a REJ packet and retransmit the requested data packet(s).
OBJECT-TYPE    
  INTEGER noPktRetrans(1), pktRetrans(2)  

aix1PktOperSendInitialRestart 1.3.6.1.4.1.539.12.3.2.1.6
Enables and disables sending of an initial restart request packet when the link comes up.
OBJECT-TYPE    
  INTEGER initialRestart(1), noInitialRestart(2)  

aix1PktOperStdsBody 1.3.6.1.4.1.539.12.3.2.1.7
Selects between ISO and CCITT packet level specifications.
OBJECT-TYPE    
  INTEGER ccittPktLvl(1), isoPktLvl(2)  

aix1PktOperFacilChecking 1.3.6.1.4.1.539.12.3.2.1.8
Enables and disables packet level checking of the facilities field of call processing packets for validity.
OBJECT-TYPE    
  INTEGER checkFacils(1), noCheckFacils(2)  

aix1PktOperUndefinedFacils 1.3.6.1.4.1.539.12.3.2.1.9
Enables and disables packet level allowing undefined facilities to appear in the facilities field of call processing packets.
OBJECT-TYPE    
  INTEGER noUndefFacils(1), undefFacils(2)  

aix1PktOperDefMaxPktSize 1.3.6.1.4.1.539.12.3.2.1.10
The maximum packet size to use for all calls placed on this packet layer entity. If aix1PktOperNegPktSize is set to negotiate(2), this will be the proposed value for calls placed on the packett layer entity.
OBJECT-TYPE    
  INTEGER pkt128(128), pkt256(256), pkt512(512), pkt1024(1024)  

aix1PktOperDefWindowSize 1.3.6.1.4.1.539.12.3.2.1.11
The maximum packet level window size to use for all calls placed on this packet layer entity. If aix1PktOperNegWindowSize is set to negotiate(2), this will be the proposed value for calls placed on the packet layer entity.
OBJECT-TYPE    
  INTEGER 0..127  

aix1PktOperNegMaxPktSize 1.3.6.1.4.1.539.12.3.2.1.12
Determines whether this packet layer entity will originate calls which negotiate packet size.
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktOperNegWindowSize 1.3.6.1.4.1.539.12.3.2.1.13
Determines whether this packet layer entity will originate calls which negotiate window size.
OBJECT-TYPE    
  INTEGER noNegotiation(1), negotiate(2)  

aix1PktOperPacketizingTimer 1.3.6.1.4.1.539.12.3.2.1.14
The interval from the time of receipt of the first character from the TDM backplane to transmission of a block of characters to the X.25 protocol stack for transmission in a data packet to the network. In 100ths of a second. This value is not meaningful on backplane connections on which escape framing, TL1 packetizing, or programmable forwarding characters are active.
OBJECT-TYPE    
  INTEGER 0..255  

aix1PktOperPVCOffset 1.3.6.1.4.1.539.12.3.2.1.15
Specifies an offset that gets added to the PVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktOperSVCOffset 1.3.6.1.4.1.539.12.3.2.1.16
Specifies an offset that gets added to the SVC logical channel range specified by x25AdmnMaxActiveCircuits and x25AdmnNumberPVCs from RFC 1382.
OBJECT-TYPE    
  INTEGER 0..4095  

aix1PktStatTable 1.3.6.1.4.1.539.12.3.3
The table of statistical elements which apply to an individual X.25 link at the packet layer.
OBJECT-TYPE    
  SEQUENCE OF  
    PktStatEntry

aix1PktStatEntry 1.3.6.1.4.1.539.12.3.3.1
The addressing information for one of this X.25 link's packet layer statistical objects.
OBJECT-TYPE    
  PktStatEntry  

aix1PktStatIndex 1.3.6.1.4.1.539.12.3.3.1.1
The ifIndex value of the packet layer entity associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1PktStatInCharsPerSec80s 1.3.6.1.4.1.539.12.3.3.1.2
The average number of data characters (characters in the data field of X.25 data packets) received from the network per second over the last 80 seconds by this packet layer entity.
OBJECT-TYPE    
  Counter32  

aix1PktStatOutCharsPerSec80s 1.3.6.1.4.1.539.12.3.3.1.3
The average number of data characters (characters in the data field of X.25 data packets) transmitted to the network per second over the last 80 seconds by this packet layer entity.
OBJECT-TYPE    
  Counter32  

aiX1Frm 1.3.6.1.4.1.539.12.4
OBJECT IDENTIFIER    

aix1FrmAdminTable 1.3.6.1.4.1.539.12.4.1
The table of administrative elements which apply to an individual X.25 link at the frame layer.
OBJECT-TYPE    
  SEQUENCE OF  
    FrmAdminEntry

aix1FrmAdminEntry 1.3.6.1.4.1.539.12.4.1.1
The addressing information for one of this X.25 link's frame layer administrative objects.
OBJECT-TYPE    
  FrmAdminEntry  

aix1FrmAdminIndex 1.3.6.1.4.1.539.12.4.1.1.1
The ifIndex value of the frame layer entity associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1FrmAdminIdleRRs 1.3.6.1.4.1.539.12.4.1.1.2
Enables and disables transmission of idle Receive Ready frames by the frame layer.
OBJECT-TYPE    
  INTEGER idleRRs(1), noIdleRRs(2)  

aix1FrmAdminRandomizeT1 1.3.6.1.4.1.539.12.4.1.1.3
Enables and disables the introduction of random jitter into the frame layer's T1 timer to avoid T1 timer synchronization with the remote frame layer.
OBJECT-TYPE    
  INTEGER randomT1(1), noRandomT1(2)  

aix1FrmOperTable 1.3.6.1.4.1.539.12.4.2
The table of operational elements which apply to an individual X.25 link at the frame layer.
OBJECT-TYPE    
  SEQUENCE OF  
    FrmOperEntry

aix1FrmOperEntry 1.3.6.1.4.1.539.12.4.2.1
The addressing information for one of this X.25 link's frame layer operational objects.
OBJECT-TYPE    
  FrmOperEntry  

aix1FrmOperIndex 1.3.6.1.4.1.539.12.4.2.1.1
The ifIndex value of the frame level associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1FrmOperIdleRRs 1.3.6.1.4.1.539.12.4.2.1.2
Enables and disables transmission of idle Receive Ready frames by the frame layer.
OBJECT-TYPE    
  INTEGER idleRRs(1), noIdleRRs(2)  

aix1FrmOperRandomizeT1 1.3.6.1.4.1.539.12.4.2.1.3
Enables and disables the introduction of random jitter into the frame layer's T1 timer to avoid T1 timer synchronization with the remote frame layer.
OBJECT-TYPE    
  INTEGER randomT1(1), noRandomT1(2)  

aiX1Phys 1.3.6.1.4.1.539.12.5
OBJECT IDENTIFIER    

aix1PhysAdminTable 1.3.6.1.4.1.539.12.5.1
The table of administrative elements which apply to an individual X.25 link at the physical layer.
OBJECT-TYPE    
  SEQUENCE OF  
    PhysAdminEntry

aix1PhysAdminEntry 1.3.6.1.4.1.539.12.5.1.1
The addressing information for one of this X.25 link's physical layer administrative objects.
OBJECT-TYPE    
  PhysAdminEntry  

aix1PhysAdminIndex 1.3.6.1.4.1.539.12.5.1.1.1
The ifIndex value of the physical port associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1PhysAdminInterFrameDelayStatus 1.3.6.1.4.1.539.12.5.1.1.2
Enables and disables a delay period between transmitted frames.
OBJECT-TYPE    
  INTEGER ifdDisabled(1), ifdEnabled(2)  

aix1PhysAdminInterFrameDelayInterval 1.3.6.1.4.1.539.12.5.1.1.3
Sets the interframe delay interval. This value is effective only if aix1PhysAdminInterFrameDelayStatus is set to ifdEnabled(2). This value is expressed in microseconds, with 100 microsecond granularity (it's truncated to the nearest 100 microseconds).
OBJECT-TYPE    
  INTEGER 0..'7fffffff'h  

aix1PhysAdminT1LineBuildOut 1.3.6.1.4.1.539.12.5.1.1.4
The T1 line build out value. The specified syntax represents ranges of line length expressed in feet.
OBJECT-TYPE    
  INTEGER lbo0to133(1), lbo133to266(2), lbo266to399(3), lbo399to533(4), lbo533to655(5)  

aix1PhysOperTable 1.3.6.1.4.1.539.12.5.2
The table of operational elements which apply to an individual X.25 link at the physical layer.
OBJECT-TYPE    
  SEQUENCE OF  
    PhysOperEntry

aix1PhysOperEntry 1.3.6.1.4.1.539.12.5.2.1
The addressing information for one of this X.25 link's physical layer operational objects.
OBJECT-TYPE    
  PhysOperEntry  

aix1PhysOperIndex 1.3.6.1.4.1.539.12.5.2.1.1
The ifIndex value of the physical port associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1PhysOperInterFrameDelayStatus 1.3.6.1.4.1.539.12.5.2.1.2
Enables and disables a delay period between transmitted frames.
OBJECT-TYPE    
  INTEGER ifdDisabled(1), ifdEnabled(2)  

aix1PhysOperInterFrameDelayInterval 1.3.6.1.4.1.539.12.5.2.1.3
Sets the interframe delay interval. This value is effective only if aix1PhysAdminInterFrameDelayStatus is set to ifdEnabled(2). This value is expressed in microseconds, with 100 microsecond granularity (it's truncated to the nearest 100 microseconds).
OBJECT-TYPE    
  INTEGER 0..'7fffffff'h  

aix1PhysOperT1LineBuildOut 1.3.6.1.4.1.539.12.5.2.1.4
The T1 line build out value. The specified syntax represents ranges of line length expressed in feet.
OBJECT-TYPE    
  INTEGER lbo0to133(1), lbo133to266(2), lbo266to399(3), lbo399to533(4), lbo533to655(5)  

aix1PhysStatTable 1.3.6.1.4.1.539.12.5.3
The table of statistical elements which apply to an individual X.25 link at the physical layer.
OBJECT-TYPE    
  SEQUENCE OF  
    PhysStatEntry

aix1PhysStatEntry 1.3.6.1.4.1.539.12.5.3.1
The addressing information for one of this X.25 link's physical layer statistical objects.
OBJECT-TYPE    
  PhysStatEntry  

aix1PhysStatIndex 1.3.6.1.4.1.539.12.5.3.1.1
The ifIndex value of the physical port associated with these objects.
OBJECT-TYPE    
  IfIndexType  

aix1PhysStatTxAborts 1.3.6.1.4.1.539.12.5.3.1.2
The number of abort sequences transmitted on the serial interfaces. This is a proprietary object because the RS232-like MIB (RFC 1659) doesn't define a similar object! RFC 1659 defines a counter for receive aborts, but not transmit aborts.
OBJECT-TYPE    
  Counter32  

aiX1VC 1.3.6.1.4.1.539.12.6
OBJECT IDENTIFIER    

aix1CircuitTable 1.3.6.1.4.1.539.12.6.1
The table of objects which maps logical channel number and packet level ifIndex number to Virtual Connection(VC) number.
OBJECT-TYPE    
  SEQUENCE OF  
    CircuitEntry

aix1CircuitEntry 1.3.6.1.4.1.539.12.6.1.1
The addressing information for the VC Circuit table.
OBJECT-TYPE    
  CircuitEntry  

aix1CircuitLinkId 1.3.6.1.4.1.539.12.6.1.1.1
The ifindex value of the packet layer entity.
OBJECT-TYPE    
  IfIndexType  

aix1CircuitChannelNumber 1.3.6.1.4.1.539.12.6.1.1.2
X.25 logical channel number.
OBJECT-TYPE    
  INTEGER 0..4095  

aix1CircuitState 1.3.6.1.4.1.539.12.6.1.1.3
The call processing state of the local Virtual Connection. This is not a standard packet level state. This is the call processing state of the AI version 7 system firmware that mediates between the X.25 protocol stack and AISwitch internal connection mechanisms.
OBJECT-TYPE    
  INTEGER idle(1), active(2), csCall(3), csDisco(4), csCancel(5), csReject(6), csCol(7), csUncol(8), npCall(9), npDisco(10), npCancel(11), npReject(12), npCol(13), npUncol(14), trapped(15), csSuspend(16)  

aix1CircuitConType 1.3.6.1.4.1.539.12.6.1.1.4
The type of connection currently supported by the VC.
OBJECT-TYPE    
  INTEGER lmux(1), rmux(2), debug(5), background(6), pvc(11), svc(12)  

aix1CircuitBCNumber 1.3.6.1.4.1.539.12.6.1.1.5
The number of the Bus Connection with which this VC is associated.
OBJECT-TYPE    
  INTEGER 0..31  

aix1CircuitUserData 1.3.6.1.4.1.539.12.6.1.1.6
The user data that was sent or received in the call request.
OBJECT-TYPE    
  DisplayString SIZE(0..16)  

aix1CircuitRemoteBasePort 1.3.6.1.4.1.539.12.6.1.1.7
The baseport of the card to which the SLC is connected across the backplane. This value is meaningful only when this VC is multiplexed to the other SLC. If not, the value returned is -1.
OBJECT-TYPE    
  INTEGER -1..256  

aix1CircuitRemoteVCNumber 1.3.6.1.4.1.539.12.6.1.1.8
The Virtual Connection number of the VC on the remote SLC to which this VC is connected. This value is meaningful only on multiplexed VCs.
OBJECT-TYPE    
  INTEGER 0..'ffff'h  

aix1CircuitPktsSent 1.3.6.1.4.1.539.12.6.1.1.9
The number of packets sent to the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
OBJECT-TYPE    
  Counter32  

aix1CircuitPktsRcvd 1.3.6.1.4.1.539.12.6.1.1.10
The number of packets received from the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
OBJECT-TYPE    
  Counter32  

aix1CircuitOperPVCType 1.3.6.1.4.1.539.12.6.1.1.11
Defines the relationship between a PVC and the connection-oriented AISwitch TDM backplane. The three types represented are defined as follows: Active: initiates connections across the backplane at an interval defined by the timer. Passive: waits to respond to a connection attempt across the backplane. Uses timer to wait for reset confirm from network. Accepts backplane connection if it receives reset confirmation in time. Connect on Activity: initiates connection across backplane upon the receipt of data from the network. Forwards received data once connection is established. Disconnects backplane connection if a timer interval passes with no data activity in either direction. This object will return the value none(1) if the value of aix1CircuitConType for this VC is not pvc(11). This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
OBJECT-TYPE    
  INTEGER none(1), active(2), connectOnActivity(3), passive(4)  

aix1CircuitOperPVCTimer 1.3.6.1.4.1.539.12.6.1.1.12
Defines the timer interval, in seconds used to manage the PVC's relationship with an internal backplane connection. The timer is used for different purposes depending on the value of aix1VCPVCType as described above. This object will return the value 0 if the VC in question is not associated with a PVC. This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
OBJECT-TYPE    
  INTEGER 0..600  

aix1VCTable 1.3.6.1.4.1.539.12.6.2
The table of objects containing information pertaining to Virtual Connections(VC).
OBJECT-TYPE    
  SEQUENCE OF  
    VCEntry

aix1VCEntry 1.3.6.1.4.1.539.12.6.2.1
The addressing information for the VC table.
OBJECT-TYPE    
  VCEntry  

aix1VCVCNumber 1.3.6.1.4.1.539.12.6.2.1.1
The local Virtual Connection number.
OBJECT-TYPE    
  INTEGER 0..287  

aix1VCState 1.3.6.1.4.1.539.12.6.2.1.2
The call processing state of the local Virtual Connection. This is not a standard packet level state. This is the call call processing state of the AI version 7 system firmware that mediates between the X.25 protocol stack and AISwitch internal connection mechanisms.
OBJECT-TYPE    
  INTEGER idle(1), active(2), csCall(3), csDisco(4), csCancel(5), csReject(6), csCol(7), csUncol(8), npCall(9), npDisco(10), npCancel(11), npReject(12), npCol(13), npUncol(14), trapped(15), csSuspend(16)  

aix1VCConType 1.3.6.1.4.1.539.12.6.2.1.3
The type of connection currently supported by the VC.
OBJECT-TYPE    
  INTEGER lmux(1), rmux(2), debug(5), background(6), pvc(11), svc(12)  

aix1VCBCNumber 1.3.6.1.4.1.539.12.6.2.1.4
The number of the Bus Connection with which this VC is associated.
OBJECT-TYPE    
  INTEGER 0..31  

aix1VCUserData 1.3.6.1.4.1.539.12.6.2.1.5
The user data that was sent or received in the call request.
OBJECT-TYPE    
  DisplayString SIZE(0..16)  

aix1VCRemoteBasePort 1.3.6.1.4.1.539.12.6.2.1.6
The baseport of the card to which the SLC is connected across the backplane. This value is meaningful only when this VC is multiplexed to the other SLC. If not, the value returned is -1.
OBJECT-TYPE    
  INTEGER -1..256  

aix1VCRemoteVCNumber 1.3.6.1.4.1.539.12.6.2.1.7
The Virtual Connection number of the VC on the remote SLC to which this VC is connected. This value is meaningful only on multiplexed VCs.
OBJECT-TYPE    
  INTEGER 0..'ffff'h  

aix1VCPktsSent 1.3.6.1.4.1.539.12.6.2.1.8
The number of packets sent to the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
OBJECT-TYPE    
  Counter32  

aix1VCPktsRcvd 1.3.6.1.4.1.539.12.6.2.1.9
The number of packets received from the packet level by the AI version 7 system software. This counts all kinds of packets, not just data packets.
OBJECT-TYPE    
  Counter32  

aix1VCOperPVCType 1.3.6.1.4.1.539.12.6.2.1.10
Defines the relationship between a PVC and the connection-oriented AISwitch TDM backplane. The three types represented are defined as follows: Active: initiates connections across the backplane at an interval defined by the timer. Passive: waits to respond to a connection attempt across the backplane. Uses timer to wait for reset confirm from network. Accepts backplane connection if it receives reset confirmation in time. Connect on Activity: initiates connection across backplane upon receipt of data from network. Forwards received data once connection is established. Disconnects backplane connection if a timer interval passes with no data activity in either direction. This object will return the value none(1) if the value of aix1VCConType for this VC is not pvc(11). This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
OBJECT-TYPE    
  INTEGER none(1), active(2), connectOnActivity(3), passive(4)  

aix1VCOperPVCTimer 1.3.6.1.4.1.539.12.6.2.1.11
Defines the timer interval, in seconds used to manage the PVC's relationship with an internal backplane connection. The timer is used for different purposes depending on the value of aix1VCPVCType as described above. This object will return the value 0 if the VC in question question is not associated with a PVC. This object reflects the current operational value of this parameter. Note that unlike most operational objects, it is writable. If the value of this object is changed, it modifies the current behavior of the board, but is not saved in nonvolatile memory.
OBJECT-TYPE    
  INTEGER 0..600  

aix1AdminPVCTable 1.3.6.1.4.1.539.12.6.3
The table of objects which control attributes of PVCs configured, but not necessarily in effect.
OBJECT-TYPE    
  SEQUENCE OF  
    AdminPVCEntry

aix1AdminPVCEntry 1.3.6.1.4.1.539.12.6.3.1
The addressing information for the PVC Admin table.
OBJECT-TYPE    
  AdminPVCEntry  

aix1AdminPVCLinkId 1.3.6.1.4.1.539.12.6.3.1.1
The ifindex value of the packet layer entity.
OBJECT-TYPE    
  IfIndexType  

aix1AdminPVCChannelNumber 1.3.6.1.4.1.539.12.6.3.1.2
X.25 logical channel number.
OBJECT-TYPE    
  INTEGER 0..4095  

aix1AdminPVCType 1.3.6.1.4.1.539.12.6.3.1.3
Defines the relationship between a PVC and the connection-oriented AISwitch TDM backplane. The three types represent are defined as follows: Active: initiates connections across the backplane at an interval defined by the timer. Passive: waits to respond to a connection attempt across the backplane. Uses timer to wait for reset confirm from network. Accepts the backplane connection if it receives reset confirmation in time. Connect on Activity: initiates connection across backplane upon receipt of data from network. Forwards received data once connection is established. Disconnects backplane connection if a timer interval passes with no data activity in either direction. This object will return the value none(1) if aix1AdminPVCChannelNumber doesn't correspond to a channel in the range specified by the combination of x25admnNumberPVCs and aix1PktAdminPVCOffset for the link specified by aix1AdminPVCLinkID. This object is settable, but does not reflect the mandatory operational value of this parameter.
OBJECT-TYPE    
  INTEGER none(1), active(2), connectOnActivity(3), passive(4)  

aix1AdminPVCTimer 1.3.6.1.4.1.539.12.6.3.1.4
Defines the timer interval, in seconds used to manage the PVC's relationship with an internal backplane connection. The timer is used for different purposes depending on the value of aix1VCPVCType as described above. This object will return the value 0 if aix1AdminPVCChannelNumber doesn't correspond to a channel in the range specified by the combination of x25admnNumberPVCs and aix1PktAdminPVCOffset for the link specified by aix1AdminPVCLinkID. This object is settable, but does not reflect the mandatory operational value of this parameter.
OBJECT-TYPE    
  INTEGER 0..600  

Defined Objects

IfIndexType  
INTEGER 1..2147483647    

ApplAdminEntry  
SEQUENCE    
  IfIndexType as aix1ApplAdminIndex  
  INTEGER as aix1ApplAdminLinkStart  
  INTEGER as aix1ApplAdminLinkMode  
  INTEGER as aix1ApplAdminResetErrs  
  INTEGER as aix1ApplAdminXONXOFFProto  
  INTEGER as aix1ApplAdminNMAProto  
  INTEGER as aix1ApplAdminOPSINEProto  
  INTEGER as aix1ApplAdminTL1Proto  
  DisplayString as aix1ApplAdminLinkDescription  
  INTEGER as aix1ApplAdminLinkConnectionMode  

ApplOperEntry  
SEQUENCE    
  IfIndexType as aix1ApplOperIndex  
  INTEGER as aix1ApplOperLinkMode  
  INTEGER as aix1ApplOperXONXOFFProto  
  INTEGER as aix1ApplOperNMAProto  
  INTEGER as aix1ApplOperOPSINEProto  
  INTEGER as aix1ApplOperTL1Proto  
  DisplayString as aix1ApplOperLinkDescription  
  INTEGER as aix1ApplOperLinkConnectionMode  

PktAdminEntry  
SEQUENCE    
  IfIndexType as aix1PktAdminIndex  
  INTEGER as aix1PktAdminConformanceMode  
  INTEGER as aix1PktAdminDBit  
  INTEGER as aix1PktAdminQBitMBit  
  INTEGER as aix1PktAdminUseRejectPkts  
  INTEGER as aix1PktAdminSendInitialRestart  
  INTEGER as aix1PktAdminStdsBody  
  INTEGER as aix1PktAdminFacilChecking  
  INTEGER as aix1PktAdminUndefinedFacils  
  INTEGER as aix1PktAdminDefMaxPktSize  
  INTEGER as aix1PktAdminDefWindowSize  
  INTEGER as aix1PktAdminNegMaxPktSize  
  INTEGER as aix1PktAdminNegWindowSize  
  INTEGER as aix1PktAdminPacketizingTimer  
  INTEGER as aix1PktAdminPVCOffset  
  INTEGER as aix1PktAdminSVCOffset  

PktOperEntry  
SEQUENCE    
  IfIndexType as aix1PktOperIndex  
  INTEGER as aix1PktOperConformanceMode  
  INTEGER as aix1PktOperDBit  
  INTEGER as aix1PktOperQBitMBit  
  INTEGER as aix1PktOperUseRejectPkts  
  INTEGER as aix1PktOperSendInitialRestart  
  INTEGER as aix1PktOperStdsBody  
  INTEGER as aix1PktOperFacilChecking  
  INTEGER as aix1PktOperUndefinedFacils  
  INTEGER as aix1PktOperDefMaxPktSize  
  INTEGER as aix1PktOperDefWindowSize  
  INTEGER as aix1PktOperNegMaxPktSize  
  INTEGER as aix1PktOperNegWindowSize  
  INTEGER as aix1PktOperPacketizingTimer  
  INTEGER as aix1PktOperPVCOffset  
  INTEGER as aix1PktOperSVCOffset  

PktStatEntry  
SEQUENCE    
  IfIndexType as aix1PktStatIndex  
  Counter32 as aix1PktStatInCharsPerSec80s  
  Counter32 as aix1PktStatOutCharsPerSec80s  

FrmAdminEntry  
SEQUENCE    
  IfIndexType as aix1FrmAdminIndex  
  INTEGER as aix1FrmAdminIdleRRs  
  INTEGER as aix1FrmAdminRandomizeT1  

FrmOperEntry  
SEQUENCE    
  IfIndexType as aix1FrmOperIndex  
  INTEGER as aix1FrmOperIdleRRs  
  INTEGER as aix1FrmOperRandomizeT1  

PhysAdminEntry  
SEQUENCE    
  IfIndexType as aix1PhysAdminIndex  
  INTEGER as aix1PhysAdminInterFrameDelayStatus  
  INTEGER as aix1PhysAdminInterFrameDelayInterval  
  INTEGER as aix1PhysAdminT1LineBuildOut  

PhysOperEntry  
SEQUENCE    
  IfIndexType as aix1PhysOperIndex  
  INTEGER as aix1PhysOperInterFrameDelayStatus  
  INTEGER as aix1PhysOperInterFrameDelayInterval  
  INTEGER as aix1PhysOperT1LineBuildOut  

PhysStatEntry  
SEQUENCE    
  IfIndexType as aix1PhysStatIndex  
  Counter32 as aix1PhysStatTxAborts  

CircuitEntry  
SEQUENCE    
  IfIndexType as aix1CircuitLinkId  
  INTEGER as aix1CircuitChannelNumber  
  INTEGER as aix1CircuitState  
  INTEGER as aix1CircuitConType  
  INTEGER as aix1CircuitBCNumber  
  DisplayString as aix1CircuitUserData  
  INTEGER as aix1CircuitRemoteBasePort  
  INTEGER as aix1CircuitRemoteVCNumber  
  Counter32 as aix1CircuitPktsSent  
  Counter32 as aix1CircuitPktsRcvd  
  INTEGER as aix1CircuitOperPVCType  
  INTEGER as aix1CircuitOperPVCTimer  

VCEntry  
SEQUENCE    
  INTEGER as aix1VCVCNumber 0..287  
  INTEGER as aix1VCState  
  INTEGER as aix1VCConType  
  INTEGER as aix1VCBCNumber  
  DisplayString as aix1VCUserData  
  INTEGER as aix1VCRemoteBasePort  
  INTEGER as aix1VCRemoteVCNumber  
  Counter32 as aix1VCPktsSent  
  Counter32 as aix1VCPktsRcvd  
  INTEGER as aix1VCOperPVCType  
  INTEGER as aix1VCOperPVCTimer  

AdminPVCEntry  
SEQUENCE    
  IfIndexType as aix1AdminPVCLinkId  
  INTEGER as aix1AdminPVCChannelNumber  
  INTEGER as aix1AdminPVCType  
  INTEGER as aix1AdminPVCTimer