ALCATEL-IND1-PORT-MIB

File: ALCATEL-IND1-PORT-MIB.mib (82720 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF IF-MIB
ALCATEL-IND1-BASE SNMPv2-TC

Imported symbols

OBJECT-TYPE Counter64 NOTIFICATION-TYPE
MODULE-IDENTITY TimeTicks Integer32
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
ifIndex ifInErrors ifOutErrors
softentIND1Port cmmEsmDrvTraps DisplayString

Defined Objects

alcatelIND1PortMIB 1.3.6.1.4.1.6486.800.1.2.1.5.1
This module describes an authoritative enterprise-specific Simple Network Management Protocol (SNMP) Management Information Base (MIB): This group contains the configuration information data for the Ethernet Switching Module. The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used. Copyright (C) 1995-2007 Alcatel-Lucent ALL RIGHTS RESERVED WORLDWIDE
MODULE-IDENTITY    

alcatelIND1PortNotifications 1.3.6.1.4.1.6486.800.1.2.1.5.1.0
OBJECT IDENTIFIER    

ddmNotifications 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.1
OBJECT IDENTIFIER    

ddmTemperatureThresholdViolated 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.1.0.1
This object notifies management station if an SFP/XFP/SFP+ temperature has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ temperature.
NOTIFICATION-TYPE    
  ifIndex  
  ddmNotificationType  
  ddmTemperature  

ddmVoltageThresholdViolated 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.1.0.2
This object notifies management station if an SFP/XFP/SFP+ supply voltage has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ supply voltage.
NOTIFICATION-TYPE    
  ifIndex  
  ddmNotificationType  
  ddmSupplyVoltage  

ddmCurrentThresholdViolated 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.1.0.3
This object notifies management station if an SFP/XFP/SFP+ Tx bias current has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ Tx bias current.
NOTIFICATION-TYPE    
  ifIndex  
  ddmNotificationType  
  ddmTxBiasCurrent  

ddmTxPowerThresholdViolated 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.1.0.4
This object notifies management station if an SFP/XFP/SFP+ Tx output power has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ Tx output power.
NOTIFICATION-TYPE    
  ifIndex  
  ddmNotificationType  
  ddmTxOutputPower  

ddmRxPowerThresholdViolated 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.1.0.5
This object notifies management station if an SFP/XFP/SFP+ Rx optical power has crossed any threshold or reverted from previous threshold violation for a port represented by ifIndex. It also provides the current realtime value of SFP/XFP/SFP+ Rx optical power.
NOTIFICATION-TYPE    
  ifIndex  
  ddmNotificationType  
  ddmRxOpticalPower  

esmViolationNotifications 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.2
OBJECT IDENTIFIER    

esmViolationRecoveryTimeout 1.3.6.1.4.1.6486.800.1.2.1.5.1.0.2.0.1
This object notifies management station if User-Port ports get re-enabled after esm violation recovery time
NOTIFICATION-TYPE    
  ifIndex  
  esmViolationRecoveryNotificationType  

alcatelIND1PortMIBObjects 1.3.6.1.4.1.6486.800.1.2.1.5.1.1
OBJECT IDENTIFIER    

esmConfTrap 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.1
OBJECT IDENTIFIER    

esmDrvTrapDrops 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.1.1
Partitioned port (separated due to errors).
OBJECT-TYPE    
  Integer32  

physicalPort 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2
OBJECT IDENTIFIER    

esmConfTable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1
A list of ESM Physical Port instances.
OBJECT-TYPE    
  SEQUENCE OF  
    EsmConfEntry

esmConfEntry 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1
A ESM Physical Port entry.
OBJECT-TYPE    
  EsmConfEntry  

esmPortSlot 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.1
The physical Slot number for this Ethernet Port. Slot number has been added to be used by the private Trap.
OBJECT-TYPE    
  Integer32  

esmPortIF 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.2
The on-board interface number for this Ethernet Port. Port Number has been added to be used by the private Trap.
OBJECT-TYPE    
  Integer32  

esmPortAutoSpeed 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.3
The automatically detected port line speed of this ESM port.
OBJECT-TYPE    
  INTEGER speed100(1), speed10(2), speedAuto(3), unknown(4), speed1000(5), speed10000(6)  

esmPortAutoDuplexMode 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.4
The automatically detected port duplex mode of this ESM port. Note: GigaEthernet supports only Full duplex mode. Default value for 10/100 = Half duplex mode.
OBJECT-TYPE    
  INTEGER fullDuplex(1), halfDuplex(2), autoDuplex(3), unknown(4)  

esmPortCfgSpeed 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.5
The configured port line speed of this ESM port.
OBJECT-TYPE    
  INTEGER speed100(1), speed10(2), speedAuto(3), speed1000(5), speed10000(6), speedMax100(8), speedMax1000(9)  

esmPortCfgDuplexMode 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.6
The configured port duplex mode of this ESM port. Note: GigaEthernet support only full-duplex.
OBJECT-TYPE    
  INTEGER fullDuplex(1), halfDuplex(2), autoDuplex(3)  

esmPortCfgIFG 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.7
Contains the setting of Inter-Frame Gap (IFG), in bytes for receive and transmit. The range is from 9 to 12 bytes. Note: The default value changed according to the Port type Default Bandwidth value 12 bytes 10Mbps 9600 nsec 100Mbps 960 nsec 1Gbps 96 nsec 10Gbps 9.6 nsec.
OBJECT-TYPE    
  Integer32  

esmPortPauseSlotTime 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.8
Indicates the number of microseconds the other end-station waits after the reception of a pause frame. Note: Pause Flow control is not available for 10Mbps. For 100Mbps, the possible value range is 5120 nanosec to 0.3 sec. For 1Gbps, the possible value range is 512 nanosec to 0.03 sec.
OBJECT-TYPE    
  Integer32  

esmPortMaxFloodRate 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.9
Broadcast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also.
OBJECT-TYPE    
  INTEGER mbps(1), percentage(2), pps(3)  

esmPortFloodMcastEnable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.10
Enable/disable the maximum flood rate for multicast.
OBJECT-TYPE    
  INTEGER disableMulticastFlood(2), enableMulticastFlood(1)  

esmPortCfgMaxFrameSize 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.11
Configure the value of the maximum frame size allow. For 10/100: It is a range between 1518(untagged) and 1553 bytes. For GigaEthernet: It is a range between 1518 and 10240 bytes.(OS7700,OS7800,OS8800) It is a range between 1518 and 9216 bytes.(OS6800)
OBJECT-TYPE    
  Integer32  

esmPortCfgLongEnable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.12
Allow the user to change the maximun Frame size. Note: It is not configurable for 10/100 Ethernet port.
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

esmPortCfgRuntEnable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.13
Allow the user to change the minimum Frame size.
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

esmPortCfgRuntSize 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.14
Configure the value of the minimum frame size allow per ports. The range is 0 to 64.
OBJECT-TYPE    
  Integer32  

esmPortCfgAutoNegotiation 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.15
Allow the user to enable or disable the port auto negotiation.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

esmPortCfgCrossover 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.16
Allow the user to configure port crossover.
OBJECT-TYPE    
  INTEGER mdi(1), mdix(2), auto(3)  

esmPortCfgFlow 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.17
Use the dot3PauseAdminMode from the standard MIB to configure the flow control.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

esmPortCfgHybridActiveType 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.18
This object is only applicable to hybrid ports . It indicates configured active media type.(the operational media type may be different if esmPortCfgHybridMode is configured to be preferredFiber or preferredCopper) For non hybrid ports notapplicable is returned as a status.
OBJECT-TYPE    
  INTEGER notapplicable(0), fiber(1), copper(2)  

esmPortCfgHybridMode 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.19
This object is only applicable to hybrid ports. This allows the user the user to configure the media type with which the port should come up. The user can configure the port to come as copper only or fiber only or either fiber/copper (with preference to one of them).
OBJECT-TYPE    
  INTEGER notapplicable(0), preferredCopper(1), forcedCopper(2), preferredFiber(3), forcedFiber(4)  

esmPortOperationalHybridType 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.20
This object is only applicable to hybrid ports . It indicates the actual media type that has link up and is or will be passing traffic. If link is not present the object will return none(0) value.
OBJECT-TYPE    
  INTEGER none(0), fiber(1), copper(2)  

esmPortCfgMMULowWaterMarkCellSetLimit 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.21
Per-port-per-CoS Head of Line blocking cell limits. Range is 0 - 16383 Firebolt register Offset: 0x006pp30 - 0x37 Bits: 13:0 CellSetLimit , Default: 0x0100 This setting allocates the guaranteed cells for one port's CoSx queue. After cell count over this limit, it will start using dynamic cells in port dynamic space.
OBJECT-TYPE    
  INTEGER 0..16383  

esmPortCfgMMUDynamicCellSetLimit 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.22
Per-egress port cell-based dynamic (shared buffer pool) memory usage drop and resume thresholds. This sets the limit for which the eight CoS-Qs within a port may share once the LWMCOSCELL limit is exceeded. Range is 0 - 16383 Firebolt register Offset: 0x006pp040 Bits: 13:0 Dynamic CellSetLimit , Chip Default: 0x0400 (1024). The system default value for Dynamic CellSetLimit is 0x100 (256).
OBJECT-TYPE    
  INTEGER 0..16383  

esmPortViolationBitMap 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.23
A bit map that identifies the set of Application that have blocked a port as a result of a particular violation
OBJECT-TYPE    
  BITS bEniSecurityBlockPortENI(0), bEniSecurityBlockPortSTP(1), bEniSecurityBlockPortSL(2), bEniSecurityBlockPortQoS(3), bEniSecurityBlockPortUDLD(4), bEniSecurityBlockPortETHBLK(5)  

esmPortViolationClearAll 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.24
Clear all port vioaltion
OBJECT-TYPE    
  INTEGER 0  

esmPortFloodBcastEnable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.25
Enable/disable the maximum flood rate for Broadcast.
OBJECT-TYPE    
  INTEGER disableBcastFlood(2), enableBcastFlood(1)  

esmPortFloodUnknownUcastEnable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.26
Enable/disable the maximum flood rate for unknown unicast.
OBJECT-TYPE    
  INTEGER disableUnknownUcastFlood(2), enableUnknownUcastFlood(1)  

esmPortMaxUnknownUcastFloodRate 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.27
Unknown-Unicast flood threshold type. To set the type, set esmPortMaxUnknownUcastFloodRateLimit also
OBJECT-TYPE    
  INTEGER mbps(1), percentage(2), pps(3)  

esmPortMaxMcastFloodRate 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.28
Multicast flood threshold type. To set the type, set esmPortMaxFloodRateLimit also.
OBJECT-TYPE    
  INTEGER mbps(1), percentage(2), pps(3)  

esmPortMaxFloodRateLimit 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.29
The value of the maximum broadcast flood limit. The actual range of the flood limit depends on the port speed. example: Percentage: 1 - 100 Mbps: 1 - 1000 (1G speed) PPS: 244 - 244262 (1G speed) To set the limit, set esmPortMaxFloodRate first
OBJECT-TYPE    
  Integer32  

esmPortMaxUnknownUcastFloodRateLimit 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.30
The value of the maximum unknown-unicast flood limit The actual range of the flood limit depends on the port speed. example: Percentage: 1 - 100 Mbps: 1 - 1000 (1G speed) PPS: 244 - 244262 (1G speed) To set the limit, set esmPortMaxUnknownUcastFloodRate first
OBJECT-TYPE    
  Integer32  

esmPortMaxMcastFloodRateLimit 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.31
The value of the maximum multicast flood limit The actual range of the flood limit depends on the port speed. example: Percentage: 1 - 100 Mbps: 1 - 1000 (1G speed) PPS: 244 - 244262 (1G speed) To set the limit, set esmPortMaxMcastFloodRate first
OBJECT-TYPE    
  Integer32  

esmPortCfgSFPType 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.1.1.32
This object is only applicable to fiber ports. The string indicates the type of SFP/GBIC of active media.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

alcetherStatsTable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2
A list of Ethernet statistics entries.
OBJECT-TYPE    
  SEQUENCE OF  
    AlcetherStatsEntry

alcetherStatsEntry 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1
A collection of statistics kept for a particular Ethernet interface. As an example, an instance of the etherStatsPkts object might be named alcetherStatsPkts.1
OBJECT-TYPE    
  AlcetherStatsEntry  

alcetherClearStats 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.1
Used to Clear all Statistics counters. By default, this object contains zero value.
OBJECT-TYPE    
  INTEGER default(0), reset(1)  

alcetherLastClearStats 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.2
The value of SysUpTime at the time of all the statistics counters are cleared. By default, this object contains a zero value.
OBJECT-TYPE    
  TimeTicks  

alcetherStatsCRCAlignErrors 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.3
The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).
OBJECT-TYPE    
  Counter64  

alcetherStatsRxUndersizePkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.4
The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxUndersizePkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.5
The total number of packets transmitted that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxOversizePkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.6
The total number of packets transmitted that were longer than 1518 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxJabbers 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.7
The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that this definition of jabber is different than the definition in IEEE-802.3 section 8.2.1.5 (10BASE5) and section 10.3.1.4 (10BASE2). These documents define jabber as the condition where any packet exceeds 20 ms. The allowed range to detect jabber is between 20 ms and 150 ms.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxCollisions 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.8
The best estimate of the total number of collisions on this Ethernet segment (in reception). Only for Ethernet Interfaces. The value returned will depend on the location of the RMON probe. Section 8.2.1.3 (10BASE-5) and section 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a station must detect a collision, in the receive mode, if three or more stations are transmitting simultaneously. A repeater port must detect a collision when two or more stations are transmitting simultaneously. Thus a probe placed on a repeater port could record more collisions than a probe connected to a station on the same segment would. Probe location plays a much smaller role when considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions. Note also that an RMON probe inside a repeater should ideally report collisions between the repeater and one or more other hosts (transmit collisions as defined by IEEE 802.3k) plus receiver collisions observed on any coax segments to which the repeater is connected.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxCollisions 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.9
The best estimate of the total number of collisions on this Ethernet segment (in transmition). Only for Ethernet Interfaces. The value returned will depend on the location of the RMON probe. Section 8.2.1.3 (10BASE-5) and section 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a station must detect a collision, in the receive mode, if three or more stations are transmitting simultaneously. A repeater port must detect a collision when two or more stations are transmitting simultaneously. Thus a probe placed on a repeater port could record more collisions than a probe connected to a station on the same segment would. Probe location plays a much smaller role when considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions. Note also that an RMON probe inside a repeater should ideally report collisions between the repeater and one or more other hosts (transmit collisions as defined by IEEE 802.3k) plus receiver collisions observed on any coax segments to which the repeater is connected.
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts64Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.10
The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets).
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts65to127Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.11
The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets).
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts128to255Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.12
The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets).
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts256to511Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.13
The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets).
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts512to1023Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.14
The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets).
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts1024to1518Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.15
The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). For both Ethernet and GigaEthernet.
OBJECT-TYPE    
  Counter64  

gigaEtherStatsPkts1519to4095Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.16
The total number of packets (including bad packets) received that were between 1519 and 4095 octets in length inclusive (excluding framing bits but including FCS octets). Only for GigaEthernet interfaces
OBJECT-TYPE    
  Counter64  

gigaEtherStatsPkts4096to9215Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.17
The total number of packets (including bad packets) received that were between 4096 and 9215 octets in length inclusive (excluding framing bits but including FCS octets). Only for GigaEthernet interfaces
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts1519to2047Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.18
The total number of frames(including error packets) received that were between 1519 and 2047 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts2048to4095Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.19
The total number of frames(including error packets) received that were between 2048 and 4095 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsPkts4096Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.20
The total number of frames(including error packets) received that were greater than or equal to 4096 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsRxGiantPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.21
The total number of frames that are greater than the specified Max length value, with a valid CRC, dropped because too long.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxDribbleNibblePkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.22
The total number of frames for which a dribble nibble has been received and CRC is correct.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxLongEventPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.23
The total number of frames for which the Carrier sense exceeds 50000 bit times for 10 Mbits/sec or 80000 bit times for 100 Mbits/sec.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxVlanTagPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.24
The total number of frames for which Type/Length field contains the VLAN protocol identifier (0x8100).
OBJECT-TYPE    
  Counter64  

alcetherStatsRxControlPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.25
The total number of frames that were recognized as control frames.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxLenChkErrPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.26
The total number of frames for which the frame length field value in the Type/Length field does not match the actual data bytes length and is NOT a type field.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxCodeErrPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.27
The total number of frames for which one or more nibbles were signaled as errors during reception of the frame.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxDvEventPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.28
The total number of frames for which a RX_DV event (packet not too long enough to be valid packet) has been seen before the correct frame.
OBJECT-TYPE    
  Counter64  

alcetherStatsRxPrevPktDropped 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.29
The total number of frames for which a packet has been dropped (because of too small IFG) before the correct frame.
OBJECT-TYPE    
  Counter64  

alcetherStatsTx64Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.30
The total number of transmitted frames of 64 bytes.
OBJECT-TYPE    
  Counter64  

alcetherStatsTx65to127Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.31
The total number of transmitted frames that were between 65 and 127 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTx128to255Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.32
The total number of transmitted frames that were between 128 and 255 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTx256to511Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.33
The total number of transmitted frames that were between 256 and 511 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTx512to1023Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.34
The total number of transmitted frames that were between 512 and 1023 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTx1024to1518Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.35
The total number of transmitted frames that were between 1024 and 1518 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTx1519to2047Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.36
The total number of transmitted frames that were between 1519 and 2047 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTx2048to4095Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.37
The total number of transmitted frames that were between 2048 and 4095 bytes in length inclusive (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTx4096Octets 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.38
The total number of transmitted frames that were greater than or equal to 4096 bytes in length and less than Max frame length (excluding framing bits but including FCS bytes).
OBJECT-TYPE    
  Counter64  

alcetherStatsTxRetryCount 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.39
The total number of collisions that the frames faced during transmission attempts.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxVlanTagPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.40
The total number of transmitted frames for which Type/Length field contains the VLAN protocol identifier (0x8100).
OBJECT-TYPE    
  Counter64  

alcetherStatsTxControlPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.41
The total number of transmitted frames that were recognised as control frames.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxLatePkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.42
The total number of late collisions that occured beyond the collision window.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxTotalBytesOnWire 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.43
The total number of bytes transmitted on wire, including all bytes from collided attempts.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxLenChkErrPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.44
The total number of transmitted frames for which the frame length field value in the Type/Length field does not match the actual data bytes length and is NOT a Type field.
OBJECT-TYPE    
  Counter64  

alcetherStatsTxExcDeferPkts 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.2.1.45
The total number of frames that were deferred in excess of 6071 nibble-times in 100 Mbps, 24287 bit-times in 10 Mbps mode. These frames are dropped.(This stat is only in case of Half duplex and excessive defer bit reset).
OBJECT-TYPE    
  Counter64  

esmHybridConfTable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3
A list of inactive hybrid port instances.
OBJECT-TYPE    
  SEQUENCE OF  
    EsmHybridConfEntry

esmHybridConfEntry 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1
A ESM Physical Port entry.
OBJECT-TYPE    
  EsmHybridConfEntry  

esmHybridPortCfgSpeed 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1.1
The configured port line speed of this ESM port.
OBJECT-TYPE    
  INTEGER speed100(1), speed10(2), speedAuto(3), speed1000(5), speed10000(6), speedMax100(8), speedMax1000(9)  

esmHybridPortCfgDuplexMode 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1.2
The configured port duplex mode of this ESM port. Note: GigaEthernet support only full-duplex.
OBJECT-TYPE    
  INTEGER fullDuplex(1), halfDuplex(2), autoDuplex(3)  

esmHybridPortCfgAutoNegotiation 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1.3
Allow the user to enable or disable the port auto negotiation.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

esmHybridPortCfgCrossover 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1.4
Allow the user to configure port crossover.
OBJECT-TYPE    
  INTEGER mdi(1), mdix(2), auto(3)  

esmHybridPortCfgFlow 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1.5
This object is used for flow control of hybrid ports. It is similar to the dot3PauseAdminMode object in dot3PauseTable. It is used to configure pause for fiber media.
OBJECT-TYPE    
  INTEGER disable(1), enabledXmit(2), enabledRcv(3), enabledXmitAndRcv(4)  

esmHybridPortCfgInactiveType 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1.6
This object is only applicable to hybrid ports . It indicates the configured inactive media type.
OBJECT-TYPE    
  INTEGER fiber(1), copper(2)  

esmHybridPortCfgSFPType 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.3.1.7
This object is only applicable to fiber ports. The string indicates the type of SFP/GBIC of active media.
OBJECT-TYPE    
  DisplayString SIZE(0..64)  

alcether10GigTable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.4
A list of 10 Gig specifics entries.
OBJECT-TYPE    
  SEQUENCE OF  
    Alcether10GigEntry

alcether10GigEntry 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.4.1
This table will be populated with the 10 gig only entries. The management interface can use it to specify if A or B is the primary.
OBJECT-TYPE    
  Alcether10GigEntry  

alcether10GigPrimary 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.4.1.1
Setting the object to 1 will make phy A as primary, 2- phy B as pirmary. Value 3 should not be set.
OBJECT-TYPE    
  INTEGER phyAprimary(1), phyBprimary(2), notApplicable(3)  

ddmInfoTable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5
The ddmInfoTable has an entry for each SFP/XFP in the system that supports Digital Diagnostic Monitoring (DDM). The table is indexed by ifIndex. Each row in this table is dynamically added and removed internally by the system based on the presence or absence of DDM capable SFP/XFP components.
OBJECT-TYPE    
  SEQUENCE OF  
    DdmEntry

ddmInfoEntry 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1
Each row represents a particular SFP/XFP that supports Digital Diagnostic Monitoring. Entries are created and deleted internally by the system.
OBJECT-TYPE    
  DdmEntry  

ddmTemperature 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.1
The value of ddmTemperature indicates the current temperature of the SFP/XFP in 1000s of degrees Celsius. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -150000..150000  

ddmTempLowWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.2
The value of ddmTempLowWarning indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a low-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -150000..150000  

ddmTempLowAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.3
The value of ddmTempLowAlarm indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a low-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -150000..150000  

ddmTempHiWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.4
The value of ddmTempHiWarning indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -150000..150000  

ddmTempHiAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.5
The value of ddmTempHiAlarm indicates the temperature of the SFP/XFP in 1000s of degrees Celsius that triggers a hi-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -150000..150000  

ddmSupplyVoltage 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.6
The value of ddmSupplyVoltage indicates the current supply voltage of the SFP/XFP in 1000s of Volts (V). A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmSupplyVoltageLowWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.7
The value of ddmSupplyVoltageLowWarning indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmSupplyVoltageLowAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.8
The value of ddmSupplyVoltageLowAlarm indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a low-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmSupplyVoltageHiWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.9
The value of ddmSupplyVoltageHiWarning indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmSupplyVoltageHiAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.10
The value of ddmSupplyVoltageHiAlarm indicates the supply voltage of the SFP/XFP in 1000s of Volts (V) that triggers a hi-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmTxBiasCurrent 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.11
The value of ddmTxBiasCurrent indicates the current Transmit Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA). A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmTxBiasCurrentLowWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.12
The value of ddmTxBiasCurrentLowWarning indicates the Transmit Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a low-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmTxBiasCurrentLowAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.13
The value of ddmTxBiasCurrentLowAlarm indicates the Transmit Bias Current of the SFP/XFP in 1000s of milli-Amperes (mA) that triggers a low-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmTxBiasCurrentHiWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.14
The value of ddmTxBiasCurrentHiWarning indicates the Transmit Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a hi-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmTxBiasCurrentHiAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.15
The value of ddmTxBiasCurrentHiAlarm indicates the Transmit Bias Current of the SFP/XFP in 1000s milli-Amperes (mA) that triggers a hi-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | 0..10000  

ddmTxOutputPower 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.16
The value of ddmTxOutputPower indicates the current Output Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmTxOutputPowerLowWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.17
The value of ddmTxOutputPowerLowWarning indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a low-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmTxOutputPowerLowAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.18
The value of ddmTxOutputPowerLowAlarm indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a low-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmTxOutputPowerHiWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.19
The value of ddmTxOutputPowerHiWarning indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a hi-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmTxOutputPowerHiAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.20
The value of ddmTxOutputPowerHiAlarm indicates the Output Power of the SFP/XFP in 1000s of dBm that triggers a hi-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmRxOpticalPower 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.21
The value of ddmRxOpticalPower indicates the current Received Optical Power of the SFP/XFP in 1000s of dBm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmRxOpticalPowerLowWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.22
The value of ddmRxOpticalPowerLowWarning indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a low-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmRxOpticalPowerLowAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.23
The value of ddmRxOpticalPowerLowAlarm indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a low-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmRxOpticalPowerHiWarning 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.24
The value of ddmRxOpticalPowerHiWarning indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a hi-warning. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

ddmRxOpticalPowerHiAlarm 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.5.1.25
The value of ddmRxOpticalPowerHiAlarm indicates the Received Optical Power of the SFP/XFP in 1000s of dBm that triggers a hi-alarm. A value of -200000 indicates this object is not applicable.
OBJECT-TYPE    
  Integer32 -200000 | -40000..10000  

esmPortModeTable 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.6
A list of ESM Physical Port Mode instances.
OBJECT-TYPE    
  SEQUENCE OF  
    EsmPortModeEntry

esmPortModeEntry 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.6.1
A ESM Physical Port Mode entry.
OBJECT-TYPE    
  EsmPortModeEntry  

esmPortModeIndex 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.6.1.1
Valid ni/port values
OBJECT-TYPE    
  INTEGER 1001..8128  

esmPortRunningMode 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.6.1.2
Currently configured Etna port 25,26 as 10G uplink user port or stacking port. Default is uplink 10G port. User can not set the current mode.
OBJECT-TYPE    
  INTEGER uplink(1), stackable(2)  

esmPortSavedMode 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.2.6.1.3
Next configured Etna port 25,26 as 10G uplink user port or stacking port. At boot up, it has the same value as current esmPortRunningMode. It takes some time to write to the EEPROM. Have at least more than 7 sec between each write operation
OBJECT-TYPE    
  INTEGER uplink(1), stackable(2)  

esmE2EFlowVlan 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.3
0 - Deleting End-to-End flow control 1-4094 - Enable End-to-End flow control and use the Vlan configured as for End-to-End flow
OBJECT-TYPE    
  INTEGER 0..4094  

ddmConfiguration 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.4
OBJECT IDENTIFIER    

ddmConfig 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.4.1
This object enables/disables DDM software feature in the system.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ddmTrapConfig 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.4.2
This objects enables/disables traps for DDM warning/alarm threshold violations.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ddmNotificationType 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.4.3
This object defines the trap type for monitored DDM parameters.
OBJECT-TYPE    
  INTEGER clearViolation(1), highAlarm(2), highWarning(3), lowWarning(4), lowAlarm(5)  

esmViolationRecovery 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.5
OBJECT IDENTIFIER    

esmViolationRecoveryTrap 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.5.1
This objects enables/disables traps for user-port shutdown
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

esmViolationRecoveryTime 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.5.2
0 - Disable the timer 30 - 600 - timeout value to re-enable the UserPort ports
OBJECT-TYPE    
  INTEGER 0..600  

esmViolationRecoveryNotificationType 1.3.6.1.4.1.6486.800.1.2.1.5.1.1.5.3
This object defines the trap type for monitored violation-recovery parameters.
OBJECT-TYPE    
  INTEGER clearViolation(1)  

alcatelIND1PortMIBConformance 1.3.6.1.4.1.6486.800.1.2.1.5.1.2
OBJECT IDENTIFIER    

alcatelIND1PortMIBCompliances 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.1
OBJECT IDENTIFIER    

esmConfPortCompliance 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.1.1
The compliance statement for the configuration of Ethernet ports.
MODULE-COMPLIANCE    

alcEtherStatsCompliance 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.1.2
The compliance statement for the Statistics of the Ethernet ports.
MODULE-COMPLIANCE    

alcatelIND1PortMIBGroups 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2
OBJECT IDENTIFIER    

esmConfMIBGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.1
A collection of objects to support the management of global configuration parameters of the Ethernet ports.
OBJECT-GROUP    

esmDetectedConfMIBGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.2
A collection of objects to support the Detected configuration parameters of the Ethernet ports.
OBJECT-GROUP    

alcEtherStatsMIBGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.3
A collection of objects to provide all the statistics related to the Ethernet and GigaEthernert ports.
OBJECT-GROUP    

alcPortNotificationGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.4
The Port MIB Notification Group.
NOTIFICATION-GROUP    

esmPortModeMIBGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.5
A collection of objects to support the management of global configuration parameters of the stacking ports.
OBJECT-GROUP    

ddmInfoGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.6
A collection of objects to provide digital diagnostics information related to SFPs, XFPs, and SFP+s.
OBJECT-GROUP    

ddmConfigGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.7
A collection of objects to allow configuration of DDM and DDM traps.
OBJECT-GROUP    

ddmNotificationsGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.8
A collection of notifications used to indicate DDM threshold violations.
NOTIFICATION-GROUP    

violationRecoveryGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.9
A collection of objects to allow configuration of violationRecovery.
OBJECT-GROUP    

violationNotificationsGroup 1.3.6.1.4.1.6486.800.1.2.1.5.1.2.2.10
A collection of notifications used to indicate esm violation recovery timeout.
NOTIFICATION-GROUP    


e2eStackTopoChangeTrap 1.3.6.1.4.1.6486.800.1.3.2.6.0.2
Trap Generated when Stack Topology changes.
NOTIFICATION-TYPE    
  esmE2EFlowVlan  

Defined Objects

EsmConfEntry  
SEQUENCE    
  Integer32 as esmPortSlot  
  Integer32 as esmPortIF  
  INTEGER as esmPortAutoSpeed  
  INTEGER as esmPortAutoDuplexMode  
  INTEGER as esmPortCfgSpeed  
  INTEGER as esmPortCfgDuplexMode  
  Integer32 as esmPortCfgIFG  
  Integer32 as esmPortPauseSlotTime  
  INTEGER as esmPortMaxFloodRate  
  INTEGER as esmPortFloodMcastEnable  
  Integer32 as esmPortCfgMaxFrameSize  
  INTEGER as esmPortCfgLongEnable  
  INTEGER as esmPortCfgRuntEnable  
  Integer32 as esmPortCfgRuntSize  
  INTEGER as esmPortCfgAutoNegotiation  
  INTEGER as esmPortCfgCrossover  
  INTEGER as esmPortCfgFlow  
  INTEGER as esmPortCfgHybridActiveType  
  INTEGER as esmPortCfgHybridMode  
  INTEGER as esmPortOperationalHybridType  
  INTEGER as esmPortCfgMMULowWaterMarkCellSetLimit  
  INTEGER as esmPortCfgMMUDynamicCellSetLimit  
  BITS as esmPortViolationBitMap  
  INTEGER as esmPortViolationClearAll  
  INTEGER as esmPortFloodBcastEnable  
  INTEGER as esmPortFloodUnknownUcastEnable  
  INTEGER as esmPortMaxUnknownUcastFloodRate  
  INTEGER as esmPortMaxMcastFloodRate  
  Integer32 as esmPortMaxFloodRateLimit  
  Integer32 as esmPortMaxUnknownUcastFloodRateLimit  
  Integer32 as esmPortMaxMcastFloodRateLimit  
  DisplayString as esmPortCfgSFPType  

EsmPortModeEntry  
SEQUENCE    
  INTEGER as esmPortModeIndex  
  INTEGER as esmPortRunningMode  
  INTEGER as esmPortSavedMode  

AlcetherStatsEntry  
SEQUENCE    
  INTEGER as alcetherClearStats  
  TimeTicks as alcetherLastClearStats  
  Counter64 as alcetherStatsCRCAlignErrors  
  Counter64 as alcetherStatsRxUndersizePkts  
  Counter64 as alcetherStatsTxUndersizePkts  
  Counter64 as alcetherStatsTxOversizePkts  
  Counter64 as alcetherStatsRxJabbers  
  Counter64 as alcetherStatsRxCollisions  
  Counter64 as alcetherStatsTxCollisions  
  Counter64 as alcetherStatsPkts64Octets  
  Counter64 as alcetherStatsPkts65to127Octets  
  Counter64 as alcetherStatsPkts128to255Octets  
  Counter64 as alcetherStatsPkts256to511Octets  
  Counter64 as alcetherStatsPkts512to1023Octets  
  Counter64 as alcetherStatsPkts1024to1518Octets  
  Counter64 as gigaEtherStatsPkts1519to4095Octets  
  Counter64 as gigaEtherStatsPkts4096to9215Octets  
  Counter64 as alcetherStatsPkts1519to2047Octets  
  Counter64 as alcetherStatsPkts2048to4095Octets  
  Counter64 as alcetherStatsPkts4096Octets  
  Counter64 as alcetherStatsRxGiantPkts  
  Counter64 as alcetherStatsRxDribbleNibblePkts  
  Counter64 as alcetherStatsRxLongEventPkts  
  Counter64 as alcetherStatsRxVlanTagPkts  
  Counter64 as alcetherStatsRxControlPkts  
  Counter64 as alcetherStatsRxLenChkErrPkts  
  Counter64 as alcetherStatsRxCodeErrPkts  
  Counter64 as alcetherStatsRxDvEventPkts  
  Counter64 as alcetherStatsRxPrevPktDropped  
  Counter64 as alcetherStatsTx64Octets  
  Counter64 as alcetherStatsTx65to127Octets  
  Counter64 as alcetherStatsTx128to255Octets  
  Counter64 as alcetherStatsTx256to511Octets  
  Counter64 as alcetherStatsTx512to1023Octets  
  Counter64 as alcetherStatsTx1024to1518Octets  
  Counter64 as alcetherStatsTx1519to2047Octets  
  Counter64 as alcetherStatsTx2048to4095Octets  
  Counter64 as alcetherStatsTx4096Octets  
  Counter64 as alcetherStatsTxRetryCount  
  Counter64 as alcetherStatsTxVlanTagPkts  
  Counter64 as alcetherStatsTxControlPkts  
  Counter64 as alcetherStatsTxLatePkts  
  Counter64 as alcetherStatsTxTotalBytesOnWire  
  Counter64 as alcetherStatsTxLenChkErrPkts  
  Counter64 as alcetherStatsTxExcDeferPkts  

Alcether10GigEntry  
SEQUENCE    
  INTEGER as alcether10GigPrimary  

EsmHybridConfEntry  
SEQUENCE    
  INTEGER as esmHybridPortCfgSpeed  
  INTEGER as esmHybridPortCfgDuplexMode  
  INTEGER as esmHybridPortCfgAutoNegotiation  
  INTEGER as esmHybridPortCfgCrossover  
  INTEGER as esmHybridPortCfgFlow  
  INTEGER as esmHybridPortCfgInactiveType  
  DisplayString as esmHybridPortCfgSFPType  

DdmEntry  
SEQUENCE    
  Integer32 as ddmTemperature  
  Integer32 as ddmTempLowWarning  
  Integer32 as ddmTempLowAlarm  
  Integer32 as ddmTempHiWarning  
  Integer32 as ddmTempHiAlarm  
  Integer32 as ddmSupplyVoltage  
  Integer32 as ddmSupplyVoltageLowWarning  
  Integer32 as ddmSupplyVoltageLowAlarm  
  Integer32 as ddmSupplyVoltageHiWarning  
  Integer32 as ddmSupplyVoltageHiAlarm  
  Integer32 as ddmTxBiasCurrent  
  Integer32 as ddmTxBiasCurrentLowWarning  
  Integer32 as ddmTxBiasCurrentLowAlarm  
  Integer32 as ddmTxBiasCurrentHiWarning  
  Integer32 as ddmTxBiasCurrentHiAlarm  
  Integer32 as ddmTxOutputPower  
  Integer32 as ddmTxOutputPowerLowWarning  
  Integer32 as ddmTxOutputPowerLowAlarm  
  Integer32 as ddmTxOutputPowerHiWarning  
  Integer32 as ddmTxOutputPowerHiAlarm  
  Integer32 as ddmRxOpticalPower  
  Integer32 as ddmRxOpticalPowerLowWarning  
  Integer32 as ddmRxOpticalPowerLowAlarm  
  Integer32 as ddmRxOpticalPowerHiWarning  
  Integer32 as ddmRxOpticalPowerHiAlarm