| APPIAN-SMI-MIB | APPIAN-CHASSIS-MIB | SNMPv2-SMI |
| SNMPv2-TC |
| acPport | AcSlotNumber | AcPortNumber |
| AcNodeId | acChassisCurrentTime | acChassisRingId |
| MODULE-IDENTITY | OBJECT-TYPE | NOTIFICATION-TYPE |
| TEXTUAL-CONVENTION | DisplayString |
| acPfot | 1.3.6.1.4.1.2785.2.3.7 | ||
| Appian Communications Pluggable Fiber Optic Transceiver MIB which contains the configuration attributes for use of pluggable fiber optic transceiver technology in the OSAP product. | |||
| MODULE-IDENTITY | |||
| acPfotTraps | 1.3.6.1.4.1.2785.2.3.7.0 | ||
| OBJECT IDENTIFIER | |||
| acPfotCfgErrorTrap | 1.3.6.1.4.1.2785.2.3.7.0.1 | ||
| The transeiver type for a port is different than the type configured for use. | |||
| NOTIFICATION-TYPE | |||
| acChassisCurrentTime | |||
| acChassisRingId | |||
| acPfotNodeId | |||
| acPfotSlot | |||
| acPfotPort | |||
| acPfotCfgType | |||
| acPfotType | |||
| acPfotTable | 1.3.6.1.4.1.2785.2.3.7.1 | ||
| A table containing the configuration parameters for pluggable fiber optic transceiver in use on a port. The index keys used in this table (node-id.slot.port) are mapped to ifIndex under the appian(2785).interfaces(4).ifTable(1) group. The configuration table will be automatically created by the module driver, regardless of if a transceiver exists on the port or not. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AcPfotEntry | |||
| acPfotEntry | 1.3.6.1.4.1.2785.2.3.7.1.1 | ||
| A row which contains the configuration parameters for an physical port equipped with pluggable fiber optic transceiver technology. These rows are automatically instantiated by default. | |||
| OBJECT-TYPE | |||
| AcPfotEntry | |||
| acPfotNodeId | 1.3.6.1.4.1.2785.2.3.7.1.1.1 | ||
| The node id is the id for this specific node in the OSAP ring. | |||
| OBJECT-TYPE | |||
| AcNodeId | |||
| acPfotSlot | 1.3.6.1.4.1.2785.2.3.7.1.1.2 | ||
| The slot number within the chassis where this module entry resides. | |||
| OBJECT-TYPE | |||
| AcSlotNumber | |||
| acPfotPort | 1.3.6.1.4.1.2785.2.3.7.1.1.3 | ||
| The port number on the module which is equipped with a pluggable fiber optic transceiver. | |||
| OBJECT-TYPE | |||
| AcPortNumber | |||
| acPfotCfgType | 1.3.6.1.4.1.2785.2.3.7.1.1.4 | ||
| The desired configured type of transceiver to be used on this port. By default, set to not-present. | |||
| OBJECT-TYPE | |||
| AcPfotType | |||
| acPfotType | 1.3.6.1.4.1.2785.2.3.7.1.1.5 | ||
| The current transceiver type detected on this port. | |||
| OBJECT-TYPE | |||
| AcPfotType | |||
| acPfotConnectorType | 1.3.6.1.4.1.2785.2.3.7.1.1.6 | ||
| The current type of connector detected on the tranceiver installed in this port. | |||
| OBJECT-TYPE | |||
| INTEGER | none(0), sc(1), lc(2), mtrj(3) | ||
| acPfotVendorName | 1.3.6.1.4.1.2785.2.3.7.1.1.7 | ||
| A string represetning the name of the Vendor that manufactured the transceiver installed in this port. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..64) | ||
| acPfotVendorPartNumber | 1.3.6.1.4.1.2785.2.3.7.1.1.8 | ||
| A string representing the vendor part number used to identify the transceiver installed in this port. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..64) | ||
| AcPfotType | |||
| The type of transceiver in use on a port expressed as an integer enumeration. This name includes an indication of the technology supported (Gigabit, Sonet etc), and reach (short, intermediate, or long). | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | not-present(0), sfp-gbe-sx(1), sfp-gbe-lx-sr(2), sfp-gbe-lx-ir(3), sfp-gbe-lx-lr(4) | ||
| AcPfotEntry | |||
| SEQUENCE | |||
| AcNodeId as acPfotNodeId | |||
| AcSlotNumber as acPfotSlot | |||
| AcPortNumber as acPfotPort | |||
| AcPfotType as acPfotCfgType | |||
| AcPfotType as acPfotType | |||
| INTEGER as acPfotConnectorType | |||
| DisplayString as acPfotVendorName | |||
| DisplayString as acPfotVendorPartNumber | |||