APPIAN-STRATUM-MIB

File: APPIAN-STRATUM-MIB.mib (14881 bytes)

Imported modules

APPIAN-SMI-MIB APPIAN-CHASSIS-MIB SNMPv2-SMI
SNMPv2-TC

Imported symbols

acOsap AcOpStatus AcNodeId
acChassisCurrentTime acChassisRingId MODULE-IDENTITY
OBJECT-TYPE NOTIFICATION-TYPE TruthValue

Defined Objects

acStratum 1.3.6.1.4.1.2785.2.9
Appian Communications Stratum MIB contain the definitions for the configuration and control of Stratum Clock module hardware information and status.
MODULE-IDENTITY    

acStratumTraps 1.3.6.1.4.1.2785.2.9.0
OBJECT IDENTIFIER    

acStratumFailedModuleATrap 1.3.6.1.4.1.2785.2.9.0.1
The stratum clock module failed.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  

acStratumFailedModuleBTrap 1.3.6.1.4.1.2785.2.9.0.2
The stratum clock module failed.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  

acStratumClockFailureModuleATrap 1.3.6.1.4.1.2785.2.9.0.3
Stratum clock agent has detected a clock timing failure.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  
  acStratumAlarmStatusModuleA  

acStratumClockFailureModuleBTrap 1.3.6.1.4.1.2785.2.9.0.4
Stratum clock agent has detected a clock timing failure.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  
  acStratumAlarmStatusModuleB  

acStratumRemovalModuleATrap 1.3.6.1.4.1.2785.2.9.0.5
The stratum clock module has been removed from the system.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  

acStratumRemovalModuleBTrap 1.3.6.1.4.1.2785.2.9.0.6
The stratum clock module has been removed from the system.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  

acStratumInsertedModuleATrap 1.3.6.1.4.1.2785.2.9.0.7
A stratum clock module has been inserted into the system.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  

acStratumInsertedModuleBTrap 1.3.6.1.4.1.2785.2.9.0.8
A stratum clock module has been inserted into the system.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  

acStratumClockModuleAOk 1.3.6.1.4.1.2785.2.9.0.9
Stratum clock agent has recovered clock timing.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  
  acStratumAlarmStatusModuleA  

acStratumClockModuleBOk 1.3.6.1.4.1.2785.2.9.0.10
Stratum clock agent has recovered clock timing.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  
  acStratumAlarmStatusModuleB  

acStratumSystemClockSourceChange 1.3.6.1.4.1.2785.2.9.0.11
Stratum clock source has changed to acStratumCurrentClockSourceSystem.
NOTIFICATION-TYPE    
  acChassisCurrentTime  
  acChassisRingId  
  acStratumNodeId  
  acStratumCurrentClockSourceSystem  

acStratumTable 1.3.6.1.4.1.2785.2.9.1
This table contains two rows for access and control of the Stratum-3 clock modules.
OBJECT-TYPE    
  SEQUENCE OF  
    AcStratumEntry

acStratumEntry 1.3.6.1.4.1.2785.2.9.1.1
A row within the Stratum table containing access control and status information relating to the operation of the Stratum-3 clock module.
OBJECT-TYPE    
  AcStratumEntry  

acStratumNodeId 1.3.6.1.4.1.2785.2.9.1.1.1
The unique node identification number representing a chassis within a ring of OSAP's.
OBJECT-TYPE    
  AcNodeId  

acStratumClockSource 1.3.6.1.4.1.2785.2.9.1.1.2
This attribute determines the clock source.
OBJECT-TYPE    
  INTEGER internal(1), bits(2), line(3)  

acStratumOpStatusModuleA 1.3.6.1.4.1.2785.2.9.1.1.3
This field indicates the current operational status for the clock card in slot 16, module A . Only the following values are applicable to the module: operational, offline, initializing, selfTesting, upgrading, standby, shuttingDown, failed, and hw not present.
OBJECT-TYPE    
  AcOpStatus  

acStratumOpStatusModuleB 1.3.6.1.4.1.2785.2.9.1.1.4
This field indicates the current operational status for the clock card in slot 16, module B . Only the following values are applicable to the module: operational, offline, initializing, selfTesting, upgrading, standby, shuttingDown, failed, and hw not present.
OBJECT-TYPE    
  AcOpStatus  

acStratumAlarmStatusModuleA 1.3.6.1.4.1.2785.2.9.1.1.5
This attribute contains the current status of the clock alarms. The acStratumAlarmStatus is a bit map represented as a sum. Normal may only be set if and only if no other alarms are set. The various bit positions are: 1 normal No alarm present 2 los Loss of Signal 4 lof Loss of Frame
OBJECT-TYPE    
  INTEGER 1..6  

acStratumAlarmStatusModuleB 1.3.6.1.4.1.2785.2.9.1.1.6
This attribute contains the current status of the clock alarms. The acStratumAlarmStatus is a bit map represented as a sum. Normal must be set if and oly if no other flash is set. The various bit positions are: 1 normal No alarm present 2 los Loss of Signal 4 lof Loss of Frame
OBJECT-TYPE    
  INTEGER 1..6  

acStratumCurrentClockSourceModuleA 1.3.6.1.4.1.2785.2.9.1.1.7
This attribute displays the current source that the clock card is selecting.
OBJECT-TYPE    
  INTEGER unknown(0), none(1), bits-a(2), bits-b(3), line-slot1-port1(4), line-slot1-port2(5), line-slot2-port1(6), line-slot2-port2(7), holdover(8), internal(9)  

acStratumCurrentClockSourceModuleB 1.3.6.1.4.1.2785.2.9.1.1.8
This attribute displays the current source that the clock card is selecting.
OBJECT-TYPE    
  INTEGER unknown(0), none(1), bits-a(2), bits-b(3), line-slot1-port1(4), line-slot1-port2(5), line-slot2-port1(6), line-slot2-port2(7), holdover(8), internal(9)  

acStratumLockoutReference 1.3.6.1.4.1.2785.2.9.1.1.9
This attribute is a bit mask of clock references that should be locked out from selection for the clock source. None can only be selected when no other lockout references are selected. The various bit positions are: 0 none No clock references are locked out from selection. 1 bits-a BITS source from clock module A is locked out. 2 bits-b BITS source from clock module B is locked out. 4 line-slot1 LINE timing source from SONET slot 1 is locked out. 8 line-slot2 LINE timing source from SONET slot 2 is locked out. 16 holdover-a Holdover from clock module A is locked out. 32 holdover-b Holdover from clock module B is locked out.
OBJECT-TYPE    
  INTEGER 0..63  

acStratumManualSwitch 1.3.6.1.4.1.2785.2.9.1.1.10
This attribute will manually switch the clock references. If the clock reference does not exist, is locked out, or the reference has failed, the switch will not take place.
OBJECT-TYPE    
  INTEGER none(0), bits-a(1), bits-b(2), line-slot1(3), line-slot2(4)  

acStratumForcedSwitch 1.3.6.1.4.1.2785.2.9.1.1.11
This attribute will force switch the clock references. If the clock reference does not exist or is locked out, the switch will not take place.
OBJECT-TYPE    
  INTEGER none(0), bits-a(1), bits-b(2), line-slot1(3), line-slot2(4)  

acStratumRevertiveRefSwitchEnabled 1.3.6.1.4.1.2785.2.9.1.1.12
Setting of this attribute to true(1) will the reference to revert back to the original reference when that reference become ready again.
OBJECT-TYPE    
  TruthValue  

acStratumClearAlarms 1.3.6.1.4.1.2785.2.9.1.1.13
Setting of this attribute to true(1) will cause the alarm contacts to clear. Reading this attribute will always return false.
OBJECT-TYPE    
  TruthValue  

acStratumLineTimingPortSlot1 1.3.6.1.4.1.2785.2.9.1.1.14
When configured for line timing, this value describes which port on the SONET card will be used to drive the line. This value is not applicable when not configured for line timing.
OBJECT-TYPE    
  INTEGER 1..2  

acStratumLineTimingPortSlot2 1.3.6.1.4.1.2785.2.9.1.1.15
When configured for line timing, this value describes which port on the SONET card will be used to drive the line. This value is not applicable when not configured for line timing.
OBJECT-TYPE    
  INTEGER 1..2  

acStratumBITSFramingType 1.3.6.1.4.1.2785.2.9.1.1.16
When configured for BITS timing, this value describes the type of framing that will be used on the BITS interface. This value is not applicable when not configured for BITS timing.
OBJECT-TYPE    
  INTEGER esf(1), d4(2)  

acStratumCurrentClockSourceSystem 1.3.6.1.4.1.2785.2.9.1.1.17
This attribute displays the current clock source that the system is selecting.
OBJECT-TYPE    
  INTEGER unknown(0), bits-a(1), bits-b(2), line-slot1-port1(3), line-slot1-port2(4), line-slot2-port1(5), line-slot2-port2(6), holdover-clock-a(7), holdover-clock-b(8), internal-clock-a(9), internal-clock-b(10), internal-sonet-slot1(11), internal-sonet-slot2(12)  

Defined Objects

AcStratumEntry  
SEQUENCE    
  AcNodeId as acStratumNodeId  
  INTEGER as acStratumClockSource  
  AcOpStatus as acStratumOpStatusModuleA  
  AcOpStatus as acStratumOpStatusModuleB  
  INTEGER as acStratumAlarmStatusModuleA  
  INTEGER as acStratumAlarmStatusModuleB  
  INTEGER as acStratumCurrentClockSourceModuleA  
  INTEGER as acStratumCurrentClockSourceModuleB  
  INTEGER as acStratumLockoutReference  
  INTEGER as acStratumManualSwitch  
  INTEGER as acStratumForcedSwitch  
  TruthValue as acStratumRevertiveRefSwitchEnabled  
  TruthValue as acStratumClearAlarms  
  INTEGER as acStratumLineTimingPortSlot1  
  INTEGER as acStratumLineTimingPortSlot2  
  INTEGER as acStratumBITSFramingType  
  INTEGER as acStratumCurrentClockSourceSystem