ASCEND-CALL-MIB

File: ASCEND-CALL-MIB.mib (19376 bytes)

Imported modules

ASCEND-MIB RFC1213-MIB RFC-1212

Imported symbols

callStatusGroup DisplayString OBJECT-TYPE

Defined Objects

callStatusMaximumEntries 1.3.6.1.4.1.529.11.1
The maximum number of entries that can exist in the call status table.
OBJECT-TYPE    
  INTEGER  

callStatusTable 1.3.6.1.4.1.529.11.2
A list of call status entries.
OBJECT-TYPE    
  SEQUENCE OF  
    CallStatusEntry

callStatusEntry 1.3.6.1.4.1.529.11.2.1
An entry containing object variables to describe a call's status.
OBJECT-TYPE    
  CallStatusEntry  

callStatusIndex 1.3.6.1.4.1.529.11.2.1.1
The index number for this call status entry. Its value ranges from 1 to 'callStatusMaximumEntries'.
OBJECT-TYPE    
  INTEGER  

callStatusValidFlag 1.3.6.1.4.1.529.11.2.1.2
Value indicates whether this entry indexed by 'callStatusIndex' contains valid information or not.
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

callStatusStartingTimeStamp 1.3.6.1.4.1.529.11.2.1.3
The starting time for this call in seconds since startup. A value of 0 is returned if entry is invalid (ie. 'callStatusValidFlag' is invalid(1)).
OBJECT-TYPE    
  INTEGER  

callStatusCallReferenceNum 1.3.6.1.4.1.529.11.2.1.4
The unique number identifying the session for which this call is associated. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusDataRate 1.3.6.1.4.1.529.11.2.1.5
The receive rate for ISDN calls or the baud rate for modem calls. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusSlotNumber 1.3.6.1.4.1.529.11.2.1.6
Identifies the slot of the line being used. It's value ranges between 1 and the value 'slotNumber' in Ascend's slots group. This variable is equivalent to 'slotIndex' in the slot group. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusSlotLineNumber 1.3.6.1.4.1.529.11.2.1.7
Identifies the line for network slots. This variable is equivalent to 'slotItemIndex' in Ascend's slot group. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusSlotChannelNumber 1.3.6.1.4.1.529.11.2.1.8
Identifies the channel for the particular line identified by 'callStatusSlotLineNumber'. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusModemSlotNumber 1.3.6.1.4.1.529.11.2.1.9
Identifies the slot on the device. It's value ranges between 1 and the value 'slotNumber' in Ascend's slot group. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusModemOnSlot 1.3.6.1.4.1.529.11.2.1.10
It identifies the particular port within a slot. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusIfIndex 1.3.6.1.4.1.529.11.2.1.11
The interface index, ranging from 1 to the number of interfaces specified in the MIB-II variable ifNumber. The interface identified by a particular value of this index is the same interface as identified by the same value if ifIndex. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callSessionIndex 1.3.6.1.4.1.529.11.2.1.12
The index of the associated session entry. Value ranges from 1 to 'ssnStatusMaximumSessions'. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusType 1.3.6.1.4.1.529.11.2.1.13
A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER callOutgoing(1), callIncoming(2)  

callStatusXmitRate 1.3.6.1.4.1.529.11.2.1.14
The transmit rate for ISDN calls or the baud rate for modem calls. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callStatusPortType 1.3.6.1.4.1.529.11.2.1.15
The port type associated with the call.
OBJECT-TYPE    
  INTEGER callPortUnknown(1), callPortAsync(2), callPortSync(3), callPortISDNSync(4), callPortISDNAsyncV120(5), callPortISDNAsyncV110(6), callPortVirtual(7), callPortISDNAsyncV32(8), callPortISDNAsyncVDSP(9)  

callStatusCalledParyID 1.3.6.1.4.1.529.11.2.1.16
The called party Number. In case of incoming calls this is set to the DNIS, in the case of outgoing calls this is set to the number dialed.
OBJECT-TYPE    
  DisplayString  

callStatusCallingPartyID 1.3.6.1.4.1.529.11.2.1.17
The calling party Number. In the case of incoming calls this variable is set to the CLID ( calling Line Identification ) received. This variable is set to the empty string for outgoing calls.
OBJECT-TYPE    
  DisplayString  

callStatusMultiLinkID 1.3.6.1.4.1.529.11.2.1.18
This is applicable only when the call is part of an MPP bundle, for other cases it is 0.
OBJECT-TYPE    
  INTEGER  

callStatusHighWaterMark 1.3.6.1.4.1.529.11.3
The highest number of channels ever used on the wide area network since power up. Nailed channels, if any, are also included in this count. Its value can be set to zero with a SET command.
OBJECT-TYPE    
  INTEGER  

callCurrentAnalogOutgoing 1.3.6.1.4.1.529.11.4
The number of current analog outgoing calls is returned.
OBJECT-TYPE    
  INTEGER  

callCurrentAnalogIncoming 1.3.6.1.4.1.529.11.5
The number of current analog incoming calls is returned.
OBJECT-TYPE    
  INTEGER  

callCurrentDigitalOutgoing 1.3.6.1.4.1.529.11.6
The number of current digital outgoing calls is returned.
OBJECT-TYPE    
  INTEGER  

callCurrentDigitalIncoming 1.3.6.1.4.1.529.11.7
The number of current digital incoming calls is returned.
OBJECT-TYPE    
  INTEGER  

callCurrentFROutgoing 1.3.6.1.4.1.529.11.8
The number of current frame relay outgoing calls is returned.
OBJECT-TYPE    
  INTEGER  

callCurrentFRIncoming 1.3.6.1.4.1.529.11.9
The number of current frame relay incoming calls is returned.
OBJECT-TYPE    
  INTEGER  

callTotalAnalogOutgoing 1.3.6.1.4.1.529.11.10
The total number of analog outgoing calls since system bootup or last clear of the variable is returned.
OBJECT-TYPE    
  INTEGER  

callTotalAnalogIncoming 1.3.6.1.4.1.529.11.11
The total number of analog incoming calls since system bootup or last clear of the variable is returned.
OBJECT-TYPE    
  INTEGER  

callTotalDigitalOutgoing 1.3.6.1.4.1.529.11.12
The total number of digital outgoing calls since system bootup or last clear of the variable is returned.
OBJECT-TYPE    
  INTEGER  

callTotalDigitalIncoming 1.3.6.1.4.1.529.11.13
The total number of digital incoming calls since system bootup or last clear of the variable is returned.
OBJECT-TYPE    
  INTEGER  

callTotalFROutgoing 1.3.6.1.4.1.529.11.14
The total number of frame relay outgoing calls since system bootup or last clear of the variable is returned.
OBJECT-TYPE    
  INTEGER  

callTotalFRIncoming 1.3.6.1.4.1.529.11.15
The total number of frame relay incoming calls since system bootup or last clear of the variable is returned.
OBJECT-TYPE    
  INTEGER  

callActiveTable 1.3.6.1.4.1.529.11.16
A list of active call status entries.
OBJECT-TYPE    
  SEQUENCE OF  
    CallActiveEntry

callActiveEntry 1.3.6.1.4.1.529.11.16.1
An entry containing object variables to describe an active call's status.
OBJECT-TYPE    
  CallActiveEntry  

callActiveCallReferenceNum 1.3.6.1.4.1.529.11.16.1.1
The unique number identifying the session for which this call is associated.
OBJECT-TYPE    
  INTEGER  

callActiveIndex 1.3.6.1.4.1.529.11.16.1.2
The index number for this call status entry. Its value ranges from 1 to 'callStatusMaximumEntries'.
OBJECT-TYPE    
  INTEGER  

callActiveValidFlag 1.3.6.1.4.1.529.11.16.1.3
valid(2) for all active calls.
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

callActiveStartingTimeStamp 1.3.6.1.4.1.529.11.16.1.4
The starting time for this call in seconds since startup.
OBJECT-TYPE    
  INTEGER  

callActiveDataRate 1.3.6.1.4.1.529.11.16.1.5
The receive rate for ISDN calls or the baud rate for modem calls.
OBJECT-TYPE    
  INTEGER  

callActiveSlotNumber 1.3.6.1.4.1.529.11.16.1.6
Identifies the slot of the line being used. It's value ranges between 1 and the value 'slotNumber' in Ascend's slots group. This variable is equivalent to 'slotIndex' in the slot group.
OBJECT-TYPE    
  INTEGER  

callActiveSlotLineNumber 1.3.6.1.4.1.529.11.16.1.7
Identifies the line for network slots. This variable is equivalent to 'slotItemIndex' in Ascend's slot group.
OBJECT-TYPE    
  INTEGER  

callActiveSlotChannelNumber 1.3.6.1.4.1.529.11.16.1.8
Identifies the channel for the particular line identified by 'callActiveSlotLineNumber'.
OBJECT-TYPE    
  INTEGER  

callActiveModemSlotNumber 1.3.6.1.4.1.529.11.16.1.9
Identifies the slot on the device. It's value ranges between 1 and the value 'slotNumber' in Ascend's slot group. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callActiveModemOnSlot 1.3.6.1.4.1.529.11.16.1.10
It identifies the particular port within a slot. A value of 0 is returned if entry is invalid.
OBJECT-TYPE    
  INTEGER  

callActiveIfIndex 1.3.6.1.4.1.529.11.16.1.11
The interface index, ranging from 1 to the number of interfaces specified in the MIB-II variable ifNumber. The interface identified by a particular value of this index is the same interface as identified by the same value if ifIndex.
OBJECT-TYPE    
  INTEGER  

callActiveSessionIndex 1.3.6.1.4.1.529.11.16.1.12
The index of the associated session entry. Value ranges from 1 to 'ssnActiveMaximumSessions'.
OBJECT-TYPE    
  INTEGER  

callActiveType 1.3.6.1.4.1.529.11.16.1.13
Differenciates between outgoing and incoming calls.
OBJECT-TYPE    
  INTEGER callOutgoing(1), callIncoming(2)  

callActiveXmitRate 1.3.6.1.4.1.529.11.16.1.14
The transmit rate for ISDN calls or the baud rate for modem calls.
OBJECT-TYPE    
  INTEGER  

callActivePortType 1.3.6.1.4.1.529.11.16.1.15
The port type associated with the call.
OBJECT-TYPE    
  INTEGER callPortUnknown(1), callPortAsync(2), callPortSync(3), callPortISDNSync(4), callPortISDNAsyncV120(5), callPortISDNAsyncV110(6), callPortVirtual(7), callPortISDNAsyncV32(8), callPortISDNAsyncVDSP(9)  

callActiveCalledParyID 1.3.6.1.4.1.529.11.16.1.16
The called party Number. In case of incoming calls this is set to the DNIS, in the case of outgoing calls this is set to the number dialed.
OBJECT-TYPE    
  DisplayString  

callActiveCallingPartyID 1.3.6.1.4.1.529.11.16.1.17
The calling party Number. In the case of incoming calls this variable is set to the CLID ( calling Line Identification ) received. This variable is set to the empty string for outgoing calls.
OBJECT-TYPE    
  DisplayString  

callActiveMultiLinkID 1.3.6.1.4.1.529.11.16.1.18
This is applicable only when the call is part of an MPP bundle, for other cases it is 0.
OBJECT-TYPE    
  INTEGER  

Defined Objects

CallStatusEntry  
SEQUENCE    
  INTEGER as callStatusIndex  
  INTEGER as callStatusValidFlag  
  INTEGER as callStatusStartingTimeStamp  
  INTEGER as callStatusCallReferenceNum  
  INTEGER as callStatusDataRate  
  INTEGER as callStatusSlotNumber  
  INTEGER as callStatusSlotLineNumber  
  INTEGER as callStatusSlotChannelNumber  
  INTEGER as callStatusModemSlotNumber  
  INTEGER as callStatusModemOnSlot  
  INTEGER as callStatusIfIndex  
  INTEGER as callSessionIndex  
  INTEGER as callStatusType  
  INTEGER as callStatusXmitRate  
  INTEGER as callStatusPortType  
  DisplayString as callStatusCalledParyID  
  DisplayString as callStatusCallingPartyID  
  INTEGER as callStatusMultiLinkID  

CallActiveEntry  
SEQUENCE    
  INTEGER as callActiveCallReferenceNum  
  INTEGER as callActiveIndex  
  INTEGER as callActiveValidFlag  
  INTEGER as callActiveStartingTimeStamp  
  INTEGER as callActiveDataRate  
  INTEGER as callActiveSlotNumber  
  INTEGER as callActiveSlotLineNumber  
  INTEGER as callActiveSlotChannelNumber  
  INTEGER as callActiveModemSlotNumber  
  INTEGER as callActiveModemOnSlot  
  INTEGER as callActiveIfIndex  
  INTEGER as callActiveSessionIndex  
  INTEGER as callActiveType  
  INTEGER as callActiveXmitRate  
  INTEGER as callActivePortType  
  DisplayString as callActiveCalledParyID  
  DisplayString as callActiveCallingPartyID  
  INTEGER as callActiveMultiLinkID