ASCEND-MIBATMSIG-MIB

File: ASCEND-MIBATMSIG-MIB.mib (17033 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Objects

mibatmIntfSigParams 1.3.6.1.4.1.529.23.52
OBJECT IDENTIFIER    

mibatmIntfSigParamsTable 1.3.6.1.4.1.529.23.52.1
A list of mibatmIntfSigParams profile entries.
OBJECT-TYPE    
  SEQUENCE OF  
    MibatmIntfSigParamsEntry

mibatmIntfSigParamsEntry 1.3.6.1.4.1.529.23.52.1.1
A mibatmIntfSigParams entry containing objects that maps to the parameters of mibatmIntfSigParams profile.
OBJECT-TYPE    
  MibatmIntfSigParamsEntry  

atmIntfSigParams-Shelf-o 1.3.6.1.4.1.529.23.52.1.1.1
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Slot-o 1.3.6.1.4.1.529.23.52.1.1.2
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Item-o 1.3.6.1.4.1.529.23.52.1.1.3
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-LogicalItem-o 1.3.6.1.4.1.529.23.52.1.1.4
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Address-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.52.1.1.5
The number of the shelf that the addressed physical device resides on.
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

atmIntfSigParams-Address-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.52.1.1.6
The number of the slot that the addressed physical device resides on.
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

atmIntfSigParams-Address-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.52.1.1.7
A number that specifies an addressable entity within the context of shelf and slot.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Address-LogicalItem 1.3.6.1.4.1.529.23.52.1.1.8
A number that specifies an addressable logical entity within the context of a physical address.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-MaxRestart 1.3.6.1.4.1.529.23.52.1.1.9
Maximum number of unacknowledged tx RESTART.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-MaxStatenq 1.3.6.1.4.1.529.23.52.1.1.10
Maximum number of unacknowledged tx STATUS ENQ.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T301Ms 1.3.6.1.4.1.529.23.52.1.1.11
Timer (in msec) for alerting supervision function. This timer is started on receipt of ALERT in Call received/delivered state and stopped when CONNECT is received.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T303Ms 1.3.6.1.4.1.529.23.52.1.1.12
Timer (in msec) for a response after SETUP is sent. This timer is stopped when the CONNECT, CALL PROCEEDING, or RELEASE COMPLETE is received.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T306Ms 1.3.6.1.4.1.529.23.52.1.1.13
Timer (in msec) for a RELEASE_COMPLETE to be received after a release has been sent.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T308Ms 1.3.6.1.4.1.529.23.52.1.1.14
Timer (in msec) for a response after RELEASE is sent. This is a release indication timer. This timer is started when the RELEASE message is sent and normally is stopped when the RELEASE or RELEASE COMPLETE is received.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T309Ms 1.3.6.1.4.1.529.23.52.1.1.15
Timer (in msec) for Q.SAAL to reconnect. After this time, calls are dropped. When set to 0, a default value based on an ATM signaling protocol will be used.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T310Ms 1.3.6.1.4.1.529.23.52.1.1.16
Timer (in msec) for a response after SETUP is received. Also called the CALL PROCEEDING timer.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T313Ms 1.3.6.1.4.1.529.23.52.1.1.17
Timer (in msec) for a response after CONNECT is sent. Also called the connect request timer. It is started when the CONNECT is sent and stopped when the CONNECT ACKNOWLEDGE is recieved.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T316Ms 1.3.6.1.4.1.529.23.52.1.1.18
Timer (in msec) for a response after RESTART is sent. Also called the restart request timer. It is started when the RESTART is sent and stopped when the RESTART ACKNOWLEDGE is recieved.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T317Ms 1.3.6.1.4.1.529.23.52.1.1.19
Timer (in msec) for internal clearing of call references. This timer is started as a result of a restart and cleared when all the internal call references are cleared. Should be less than the the likely value of T316 of the peer.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T322Ms 1.3.6.1.4.1.529.23.52.1.1.20
Timer (in msec) for a response after STATUS ENQ is sent.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T331Ms 1.3.6.1.4.1.529.23.52.1.1.21
Timer (in msec) for internal clearing of call references.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T333Ms 1.3.6.1.4.1.529.23.52.1.1.22
Timer (in msec) for internal clearing of call references.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T397Ms 1.3.6.1.4.1.529.23.52.1.1.23
Timer (in msec) for internal clearing of call references.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T398Ms 1.3.6.1.4.1.529.23.52.1.1.24
Timer (in msec) for receipt of a response to a DROP PARTY that was sent.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T399Ms 1.3.6.1.4.1.529.23.52.1.1.25
Timer (in msec) for receipt of a response to an ADD PARTY that was sent.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-SaalRetryMs 1.3.6.1.4.1.529.23.52.1.1.26
Timer value for retrying AAL_ESTABLISH messages.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T303NumReties 1.3.6.1.4.1.529.23.52.1.1.27
Number of times SETUP could be resent in case of T303 timer expiry.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T308NumRetries 1.3.6.1.4.1.529.23.52.1.1.28
Number of times RELEASE could be sent in case of T308 timer expiry.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T316NumRetries 1.3.6.1.4.1.529.23.52.1.1.29
Number of times RESTART could be sent in case RESTART ACK is not received withinn T316 timer expiry.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T322NumRetries 1.3.6.1.4.1.529.23.52.1.1.30
Number of times STAT ENQ could be sent before a response is received within the T322 timer expiry.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-T331NumRetries 1.3.6.1.4.1.529.23.52.1.1.31
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-Q2931Options-AssignVpiVci 1.3.6.1.4.1.529.23.52.1.1.32
In the case of UNI4.0 and PNNI this parameter specifies who assigns the VPI/VCI. TRUE will allow the local stack and FALSE will let the partner stack to assign.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-QsaalOptions-WindowSize 1.3.6.1.4.1.529.23.52.1.1.33
Q.SAAL window size
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-MaxCc 1.3.6.1.4.1.529.23.52.1.1.34
Maximum number of control PDU (BGN, END, RESYNC) retransmissions.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-MaxPd 1.3.6.1.4.1.529.23.52.1.1.35
Maximum number of Sequenced data PDU's between poll.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-MaxStat 1.3.6.1.4.1.529.23.52.1.1.36
Maximum length of STAT PDU.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TccMs 1.3.6.1.4.1.529.23.52.1.1.37
Retry time (in msec) for control PDU's(BGN, END, RESYNC).
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TpollMs 1.3.6.1.4.1.529.23.52.1.1.38
Poll sent (in msec) when active. When set to 0, a default value based on an ATM signaling protocol will be used.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TkeepaliveMs 1.3.6.1.4.1.529.23.52.1.1.39
Poll sent (in msec) when in transient state. When set to 0, a default value based on an ATM signaling protocol will be used.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TnoresponseMs 1.3.6.1.4.1.529.23.52.1.1.40
STAT received at least this period(in msec). When set to 0, a default value based on an ATM signaling protocol will be used.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-TidleMs 1.3.6.1.4.1.529.23.52.1.1.41
Poll sent (in msec) when idle -- UNI 3.1, only.
OBJECT-TYPE    
  INTEGER  

atmIntfSigParams-QsaalOptions-PollAfterRetransmission 1.3.6.1.4.1.529.23.52.1.1.42
Specifies after retransmitting PDUs whether a POLL must be sent before sending any further PDUs.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-QsaalOptions-RepeatUstat 1.3.6.1.4.1.529.23.52.1.1.43
Specifies whether two USTAT messages should be sent each time it is required to be sent.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-QsaalOptions-UstatRspToPoll 1.3.6.1.4.1.529.23.52.1.1.44
Specifies whether a USTAT should be sent in response to a POLL indicating an out of sequence PDU.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

atmIntfSigParams-Action-o 1.3.6.1.4.1.529.23.52.1.1.45
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)  

Defined Objects

DisplayString  
OCTET STRING    

MibatmIntfSigParamsEntry  
SEQUENCE    
  INTEGER as atmIntfSigParams-Shelf-o  
  INTEGER as atmIntfSigParams-Slot-o  
  INTEGER as atmIntfSigParams-Item-o  
  INTEGER as atmIntfSigParams-LogicalItem-o  
  INTEGER as atmIntfSigParams-Address-PhysicalAddress-Shelf  
  INTEGER as atmIntfSigParams-Address-PhysicalAddress-Slot  
  INTEGER as atmIntfSigParams-Address-PhysicalAddress-ItemNumber  
  INTEGER as atmIntfSigParams-Address-LogicalItem  
  INTEGER as atmIntfSigParams-Q2931Options-MaxRestart  
  INTEGER as atmIntfSigParams-Q2931Options-MaxStatenq  
  INTEGER as atmIntfSigParams-Q2931Options-T301Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T303Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T306Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T308Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T309Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T310Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T313Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T316Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T317Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T322Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T331Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T333Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T397Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T398Ms  
  INTEGER as atmIntfSigParams-Q2931Options-T399Ms  
  INTEGER as atmIntfSigParams-Q2931Options-SaalRetryMs  
  INTEGER as atmIntfSigParams-Q2931Options-T303NumReties  
  INTEGER as atmIntfSigParams-Q2931Options-T308NumRetries  
  INTEGER as atmIntfSigParams-Q2931Options-T316NumRetries  
  INTEGER as atmIntfSigParams-Q2931Options-T322NumRetries  
  INTEGER as atmIntfSigParams-Q2931Options-T331NumRetries  
  INTEGER as atmIntfSigParams-Q2931Options-AssignVpiVci  
  INTEGER as atmIntfSigParams-QsaalOptions-WindowSize  
  INTEGER as atmIntfSigParams-QsaalOptions-MaxCc  
  INTEGER as atmIntfSigParams-QsaalOptions-MaxPd  
  INTEGER as atmIntfSigParams-QsaalOptions-MaxStat  
  INTEGER as atmIntfSigParams-QsaalOptions-TccMs  
  INTEGER as atmIntfSigParams-QsaalOptions-TpollMs  
  INTEGER as atmIntfSigParams-QsaalOptions-TkeepaliveMs  
  INTEGER as atmIntfSigParams-QsaalOptions-TnoresponseMs  
  INTEGER as atmIntfSigParams-QsaalOptions-TidleMs  
  INTEGER as atmIntfSigParams-QsaalOptions-PollAfterRetransmission  
  INTEGER as atmIntfSigParams-QsaalOptions-RepeatUstat  
  INTEGER as atmIntfSigParams-QsaalOptions-UstatRspToPoll  
  INTEGER as atmIntfSigParams-Action-o