| ASCEND-MIB | RFC1155-SMI | RFC1213-MIB |
| RFC-1212 |
| slots | TimeTicks | DisplayString |
| OBJECT-TYPE |
| watchdog | 1.3.6.1.4.1.529.2.7 | ||
| OBJECT IDENTIFIER | |||
| watchdogCount | 1.3.6.1.4.1.529.2.7.1 | ||
| The number of entries in the watchdogTable | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| watchdogTable | 1.3.6.1.4.1.529.2.7.2 | ||
| The watchdog table | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| WatchdogEntry | |||
| watchdogEntry | 1.3.6.1.4.1.529.2.7.2.1 | ||
| An entry in the watchdog table | |||
| OBJECT-TYPE | |||
| WatchdogEntry | |||
| watchdogIndex | 1.3.6.1.4.1.529.2.7.2.1.1 | ||
| The index of the watchdog entry. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| watchdogName | 1.3.6.1.4.1.529.2.7.2.1.2 | ||
| A descriptive name for the watchdog | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| watchdogID | 1.3.6.1.4.1.529.2.7.2.1.3 | ||
| This defines what type of watchdog relates to this entry. The possible values are: (1) 'other' for a sensor other than the types listed, (2) 'thermal' for a temperature sensor, (3) 'fan' for a fan speed sensor, (4) 'fantray' for a sensor associated with a fantray assembly | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), thermal(2), fan(3), fantray(4) | ||
| watchdogState | 1.3.6.1.4.1.529.2.7.2.1.4 | ||
| The state of the watchdog. If the value is 'other' then the watchdog does not support state information. | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), operational(2), failed(3) | ||
| watchdogReading | 1.3.6.1.4.1.529.2.7.2.1.5 | ||
| A measurement reading of the watchdog. The unit of measurment is defined by watchdogReadingUnits. A -1 value indicates a reading of the watchdog is not supported. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| watchdogLastViolation | 1.3.6.1.4.1.529.2.7.2.1.6 | ||
| The value of sysUpTime at the time the last watchdog violation occurred (last violation trap sent). | |||
| OBJECT-TYPE | |||
| TimeTicks | |||
| watchdogLocation | 1.3.6.1.4.1.529.2.7.2.1.7 | ||
| The location of the watchdog | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| watchdogUnit | 1.3.6.1.4.1.529.2.7.2.1.8 | ||
| The unit number of the watchdog entry. This number is an unique identifier assigned to each watchdog of a particular type. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| watchdogReadingUnits | 1.3.6.1.4.1.529.2.7.2.1.9 | ||
| The measurement units of a reading from the watchdog | |||
| OBJECT-TYPE | |||
| INTEGER | other(1), celsius(2), rpm(3), noReadingSupported(4) | ||
| watchdogThreshold | 1.3.6.1.4.1.529.2.7.2.1.10 | ||
| The reading level for the watchdog that will trigger a trap | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| watchdogTrapState | 1.3.6.1.4.1.529.2.7.3 | ||
| This variable indicates whether the system produces the watchdogWarningTrap trap. | |||
| OBJECT-TYPE | |||
| INTEGER | enabled(1), disabled(2) | ||
| WatchdogEntry | |||
| SEQUENCE | |||
| INTEGER as watchdogIndex | |||
| DisplayString as watchdogName | |||
| INTEGER as watchdogID | |||
| INTEGER as watchdogState | |||
| INTEGER as watchdogReading | |||
| TimeTicks as watchdogLastViolation | |||
| DisplayString as watchdogLocation | |||
| INTEGER as watchdogUnit | |||
| INTEGER as watchdogReadingUnits | |||
| INTEGER as watchdogThreshold | |||