| RFC1155-SMI | RFC1213-MIB | RFC-1212 |
| enterprises | Gauge | DisplayString |
| OBJECT-TYPE |
| att-2 | 1.3.6.1.4.1.74 | ||
| OBJECT IDENTIFIER | |||
| att-products | 1.3.6.1.4.1.74.1 | ||
| OBJECT IDENTIFIER | |||
| att-cnmAgent | 1.3.6.1.4.1.74.1.9 | ||
| OBJECT IDENTIFIER | |||
| att-mgmt | 1.3.6.1.4.1.74.2 | ||
| OBJECT IDENTIFIER | |||
| att-cnm | 1.3.6.1.4.1.74.2.15 | ||
| OBJECT IDENTIFIER | |||
| att-cnm-sip | 1.3.6.1.4.1.74.2.15.5 | ||
| OBJECT IDENTIFIER | |||
| attCNMsipConfigTable | 1.3.6.1.4.1.74.2.15.5.1 | ||
| A list of entries containing configuration information for all SIP interfaces managed by this system. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AttCNMsipConfigEntry | |||
| attCNMsipConfigEntry | 1.3.6.1.4.1.74.2.15.5.1.1 | ||
| An entry containing configuration information for a particular SIP interface. | |||
| OBJECT-TYPE | |||
| AttCNMsipConfigEntry | |||
| attCNMsipConfigIndex | 1.3.6.1.4.1.74.2.15.5.1.1.1 | ||
| A unique value for each SIP interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipMeasMaxIntervals | 1.3.6.1.4.1.74.2.15.5.1.1.2 | ||
| This variable identifies the maximum number of measurement intervals supported for the measurements maintained by this SIP interface in the attCNMsipMeasTable. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipMeasIntervalLen | 1.3.6.1.4.1.74.2.15.5.1.1.3 | ||
| This variable identifies the number of seconds that make up one complete measurement interval for the measurements maintained by this SIP interface in the attCNMsipMeasTable. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipMeasTable | 1.3.6.1.4.1.74.2.15.5.2 | ||
| A list of entries containing traffic measurements, maintained during the specified measurement interval, for all SIP interfaces managed by this system. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AttCNMsipMeasEntry | |||
| attCNMsipMeasEntry | 1.3.6.1.4.1.74.2.15.5.2.1 | ||
| An entry containing traffic measurements, maintained during the specified measurement interval, for a particular SIP interface. | |||
| OBJECT-TYPE | |||
| AttCNMsipMeasEntry | |||
| attCNMsipMeasIndex | 1.3.6.1.4.1.74.2.15.5.2.1.1 | ||
| A unique value for each SIP interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipMeasInterval | 1.3.6.1.4.1.74.2.15.5.2.1.2 | ||
| This variable identifies the measurement interval number for which measurement is provided. It is a number between 1 and XX, where 1 identifies the most recently completed measurement interval and XX is the least recently completed measurement interval. The value of XX is specified by the attCNMsipMeasMaxIntervals object given in the attCNMsipConfigTable. The maximum length of each measurement interval is specified by the attCNMsipMeasIntervalLen object given in the attCNMsipConfigTable. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipMeasTimeStamp | 1.3.6.1.4.1.74.2.15.5.2.1.3 | ||
| The time stamp corresponding to the end of the specified measurement interval, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1, 1970. Any fraction is rounded up. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipMeasLocalTime | 1.3.6.1.4.1.74.2.15.5.2.1.4 | ||
| The time stamp corresponding to the end of the specified measurement interval. Any fraction is rounded up. It is given as a printable ASCII string showing the local time at the end of the interval. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..255) | ||
| attCNMsipReceivedL3PDUs | 1.3.6.1.4.1.74.2.15.5.2.1.5 | ||
| The counter associated with the number of individual-addressed and group-addressed L3 PDUs received by a SIP interface during the specified measurement interval. | |||
| OBJECT-TYPE | |||
| Gauge | |||
| attCNMsipSentL3PDUs | 1.3.6.1.4.1.74.2.15.5.2.1.6 | ||
| The counter associated with the number of individual-addressed and group-addressed L3 PDUs sent by a SIP interface during the specified measurement interval. | |||
| OBJECT-TYPE | |||
| Gauge | |||
| attCNMsipReceivedGroupL3PDUs | 1.3.6.1.4.1.74.2.15.5.2.1.7 | ||
| The counter associated with the number of group-addressed L3 PDUs received by a SIP interface during the specified measurement interval. | |||
| OBJECT-TYPE | |||
| Gauge | |||
| attCNMsipSentGroupL3PDUs | 1.3.6.1.4.1.74.2.15.5.2.1.8 | ||
| The counter associated with the number of group-addressed L3 PDUs sent by a SIP interface during the specified measurement interval. | |||
| OBJECT-TYPE | |||
| Gauge | |||
| attCNMsipReceivedL2PDUs | 1.3.6.1.4.1.74.2.15.5.2.1.9 | ||
| The counter associated with the number of L2 PDUs received by a SIP interface during the specified measurement interval. | |||
| OBJECT-TYPE | |||
| Gauge | |||
| attCNMsipSentL2PDUs | 1.3.6.1.4.1.74.2.15.5.2.1.10 | ||
| The counter associated with the number of L2 PDUs sent by a SIP interface during the specified measurement interval. | |||
| OBJECT-TYPE | |||
| Gauge | |||
| attCNMsipL3ErrorLogTable | 1.3.6.1.4.1.74.2.15.5.3 | ||
| A list of entries identifying the latest occurrence of protocol errors encountered at the Level 3 layer of all SIP interfaces managed by this system. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| AttCNMsipL3ErrorLogEntry | |||
| attCNMsipL3ErrorLogEntry | 1.3.6.1.4.1.74.2.15.5.3.1 | ||
| An entry identifying the latest occurrence of a specific protocol error encountered at the Level 3 layer of a particular SIP interface. | |||
| OBJECT-TYPE | |||
| AttCNMsipL3ErrorLogEntry | |||
| attCNMsipL3ErrorLogIndex | 1.3.6.1.4.1.74.2.15.5.3.1.1 | ||
| A unique value for each SIP interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipL3ErrorLogType | 1.3.6.1.4.1.74.2.15.5.3.1.2 | ||
| The type of error. It could be one of: - Destination Address Field Format Error, - Source Address Field Format Error, - Invalid BAsize Field Value, - Invalid Header Extension Length, - Invalid Header Extension: Element Length, - Invalid Header Extension: Carrier Selection Element Format, - Invalid Header Extension: Carrier Selection Element Length, - Invalid Header Extension: Version Element Position, Length or Value, - BEtag Mismatch, - BAsize Field Not Equal To Length Field, - Incorrect Length, - MSS Receive Interval Timeout. | |||
| OBJECT-TYPE | |||
| INTEGER | daFieldFormatError(1), saFieldFormatError(2), baSizeFieldValueInvalid(3), heLengthInvalid(4), heElementLengthInvalid(5), heVersionElementInvalid(6), heCarrierSelectionElementInvalid(7), hePADInvalid(8), beTagMismatch(9), baSizeFieldNotEqualLengthField(10), incorrectLength(11), mriTimeout(12) | ||
| attCNMsipL3ErrorLogSA | 1.3.6.1.4.1.74.2.15.5.3.1.3 | ||
| The SMDS source address in the rejected L3 PDU. | |||
| OBJECT-TYPE | |||
| SMDSAddress | |||
| attCNMsipL3ErrorLogDA | 1.3.6.1.4.1.74.2.15.5.3.1.4 | ||
| The SMDS destination address in the rejected L3 PDU. | |||
| OBJECT-TYPE | |||
| SMDSAddress | |||
| attCNMsipL3ErrorLogTimeStamp | 1.3.6.1.4.1.74.2.15.5.3.1.5 | ||
| The time stamp for the latest occurrence of the specified error, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1, 1970. Any fraction is rounded up. | |||
| OBJECT-TYPE | |||
| INTEGER | |||
| attCNMsipL3ErrorLogLocalTime | 1.3.6.1.4.1.74.2.15.5.3.1.6 | ||
| The time stamp for the latest occurrence of the specified error. It is given as a printable ASCII string showing the local time at the latest occurrence of this type of error. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..255) | ||
| SMDSAddress | |||
| OCTET STRING | SIZE(8) | ||
| AttCNMsipConfigEntry | |||
| SEQUENCE | |||
| INTEGER as attCNMsipConfigIndex | |||
| INTEGER as attCNMsipMeasMaxIntervals | |||
| INTEGER as attCNMsipMeasIntervalLen | |||
| AttCNMsipMeasEntry | |||
| SEQUENCE | |||
| INTEGER as attCNMsipMeasIndex | |||
| INTEGER as attCNMsipMeasInterval | |||
| INTEGER as attCNMsipMeasTimeStamp | |||
| DisplayString as attCNMsipMeasLocalTime | |||
| Gauge as attCNMsipReceivedL3PDUs | |||
| Gauge as attCNMsipSentL3PDUs | |||
| Gauge as attCNMsipReceivedGroupL3PDUs | |||
| Gauge as attCNMsipSentGroupL3PDUs | |||
| Gauge as attCNMsipReceivedL2PDUs | |||
| Gauge as attCNMsipSentL2PDUs | |||
| AttCNMsipL3ErrorLogEntry | |||
| SEQUENCE | |||
| INTEGER as attCNMsipL3ErrorLogIndex | |||
| INTEGER as attCNMsipL3ErrorLogType | |||
| SMDSAddress as attCNMsipL3ErrorLogSA | |||
| SMDSAddress as attCNMsipL3ErrorLogDA | |||
| INTEGER as attCNMsipL3ErrorLogTimeStamp | |||
| DisplayString as attCNMsipL3ErrorLogLocalTime | |||