Amperion-MIB

File: Amperion-MIB.mib (78082 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
RFC1213-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
enterprises Integer32 Unsigned32
Counter32 Counter64 Gauge32
IpAddress TimeTicks Opaque
OBJECT-GROUP DisplayString RowStatus
TruthValue ifIndex

Defined Objects

amperion 1.3.6.1.4.1.13995
Amperion Inc. private MIB
MODULE-IDENTITY    

ds2 1.3.6.1.4.1.13995.1
OBJECT IDENTIFIER    

powerline 1.3.6.1.4.1.13995.1.1
OBJECT IDENTIFIER    

plMibIIExtension 1.3.6.1.4.1.13995.1.1.1
OBJECT IDENTIFIER    

plCards 1.3.6.1.4.1.13995.1.1.1.2
OBJECT IDENTIFIER    

plCdNumber 1.3.6.1.4.1.13995.1.1.1.2.1
Number of Cards available. Maximum index of plCdTable
OBJECT-TYPE    
  Integer32  

plCdTable 1.3.6.1.4.1.13995.1.1.1.2.2
Powerline Cards Table. List of attributes of each Card available in the System. Indexed by the number of the Card (from 1 to plCdNumber).
OBJECT-TYPE    
  SEQUENCE OF  
    PlCdEntry

plCdEntry 1.3.6.1.4.1.13995.1.1.1.2.2.1
Row of table plCdTable
OBJECT-TYPE    
  PlCdEntry  

plCdIndex 1.3.6.1.4.1.13995.1.1.1.2.2.1.1
Number of powerline card. Maximum: plCdNumber
OBJECT-TYPE    
  Integer32  

plCdType 1.3.6.1.4.1.13995.1.1.1.2.2.1.2
Type of card: 0 => HE 1 => CPE
OBJECT-TYPE    
  INTEGER he(0), cpe(1)  


plCdShortMacAddress 1.3.6.1.4.1.13995.1.1.1.2.2.1.4
Short MAC Address of the Card
OBJECT-TYPE    
  Integer32  

plCdLongMacAddress 1.3.6.1.4.1.13995.1.1.1.2.2.1.5
Long MAC Address of the Card
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plCdHardwareVersion 1.3.6.1.4.1.13995.1.1.1.2.2.1.6
Hardware Version
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plCdFirmwareVersion 1.3.6.1.4.1.13995.1.1.1.2.2.1.7
Firmware Version
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plCdDriverVersion 1.3.6.1.4.1.13995.1.1.1.2.2.1.8
Driver Version
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plCdReset 1.3.6.1.4.1.13995.1.1.1.2.2.1.9
Reset to Saved Values. Soft Reset.
OBJECT-TYPE    
  Integer32  

plCdFactoryReset 1.3.6.1.4.1.13995.1.1.1.2.2.1.10
Reset to factory values. Hard Reset.
OBJECT-TYPE    
  Integer32  

plCdSaveAsPermanent 1.3.6.1.4.1.13995.1.1.1.2.2.1.11
Save MIB values as default values: the information of the Remote List (long MAC address and short MAC address of each user) is saved and will be restored after a reboot or a poweroff.
OBJECT-TYPE    
  Integer32  

plCdStatus 1.3.6.1.4.1.13995.1.1.1.2.2.1.12
Status related to the interface: 0 => OK.
OBJECT-TYPE    
  Integer32  

plCdRemoteList 1.3.6.1.4.1.13995.1.1.1.2.2.1.13
List of Long MAC Address that can be connected with HE (only HE). Returns a string with the list of long MAC address (not separated by spaces)
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plCdNumRemoteList 1.3.6.1.4.1.13995.1.1.1.2.2.1.14
Number of CPE in remote list (only HE). This is the maximum value for cpeId in Network table.
OBJECT-TYPE    
  Integer32  

plNetwork 1.3.6.1.4.1.13995.1.1.2
OBJECT IDENTIFIER    

plNetTable 1.3.6.1.4.1.13995.1.1.2.1
Network Topology. Indexed by number of card and number of remote user (.plCdIndex.cpeId). Maximum values for indexes: plCdNumber and plCdNumRemoteList. Only available in HE.
OBJECT-TYPE    
  SEQUENCE OF  
    PlNetEntry

plNetEntry 1.3.6.1.4.1.13995.1.1.2.1.1
Row of table plNetTable
OBJECT-TYPE    
  PlNetEntry  

plNetShortMacAddress 1.3.6.1.4.1.13995.1.1.2.1.1.1
SMAC of remote CPE.
OBJECT-TYPE    
  Integer32 1..9  

plNetLongMacAddress 1.3.6.1.4.1.13995.1.1.2.1.1.3
Long Mac Address of Remote Node.
OBJECT-TYPE    
  DisplayString SIZE(0..14)  

plNetRowStatus 1.3.6.1.4.1.13995.1.1.2.1.1.8
Row Status
OBJECT-TYPE    
  RowStatus  

plTransmission 1.3.6.1.4.1.13995.1.1.3
OBJECT IDENTIFIER    

plInpTable 1.3.6.1.4.1.13995.1.1.3.2
Input Channel Table. Common input characteristics. Indexed by number of card. Maximum value of index: plCdNumber
OBJECT-TYPE    
  SEQUENCE OF  
    PlInpEntry

plInpEntry 1.3.6.1.4.1.13995.1.1.3.2.1
Row of table plInpTable
OBJECT-TYPE    
  PlInpEntry  

plInpTotalOctets 1.3.6.1.4.1.13995.1.1.3.2.1.1
Total number of rx octets (including FEC overhead)
OBJECT-TYPE    
  Integer32  

plInpGain 1.3.6.1.4.1.13995.1.1.3.2.1.2
Reception gain
OBJECT-TYPE    
  Integer32  

plInpAGC 1.3.6.1.4.1.13995.1.1.3.2.1.3
To enable or disable Adaptive Rx Gain Control. 0 => AGC disabled 1 => AGC enabled.
OBJECT-TYPE    
  INTEGER agcdisabled(0), agcenabled(1)  

plInpMaxGain 1.3.6.1.4.1.13995.1.1.3.2.1.4
Maximum reception gain
OBJECT-TYPE    
  Integer32  

plInpThresholds 1.3.6.1.4.1.13995.1.1.3.2.1.5
SNR Thresholds in dB. Returns a string containing 4 integers.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plInpAttenuationGain 1.3.6.1.4.1.13995.1.1.3.2.1.6
Attenuation Gain (only HE)
OBJECT-TYPE    
  Integer32  

plInpSamsDecode 1.3.6.1.4.1.13995.1.1.3.2.1.7
Number of decoded SAMS (only CPE)
OBJECT-TYPE    
  Integer32  

plInpSamsGood 1.3.6.1.4.1.13995.1.1.3.2.1.8
Number of used SAMS (only CPE)
OBJECT-TYPE    
  Integer32  

plInpSamsBad 1.3.6.1.4.1.13995.1.1.3.2.1.9
Number of discarded SAMS (only CPE)
OBJECT-TYPE    
  Integer32  

plInpNodeTable 1.3.6.1.4.1.13995.1.1.3.4
Input Characteristics Remote equipments connected
OBJECT-TYPE    
  SEQUENCE OF  
    PlInpNodeEntry

plInpNodeEntry 1.3.6.1.4.1.13995.1.1.3.4.1
Row of table plInpNodeTable
OBJECT-TYPE    
  PlInpNodeEntry  

plInpNodeReceivedPkts 1.3.6.1.4.1.13995.1.1.3.4.1.1
Number of Packets received from cpeId user
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedUnrecPkts 1.3.6.1.4.1.13995.1.1.3.4.1.2
Number of Unrecoverable received packets
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedCorrectedPkts 1.3.6.1.4.1.13995.1.1.3.4.1.3
Number of Corrected (by FEC) received packets
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedOctets 1.3.6.1.4.1.13995.1.1.3.4.1.4
Number of Received bytes
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedCorrectedOctets 1.3.6.1.4.1.13995.1.1.3.4.1.5
Number of Corrected (by FEC) received bytes
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedPower 1.3.6.1.4.1.13995.1.1.3.4.1.6
Total received power
OBJECT-TYPE    
  Integer32  

plInpNodePLR 1.3.6.1.4.1.13995.1.1.3.4.1.7
Packet Loss Rate
OBJECT-TYPE    
  Integer32  

plInpNodeMeanBPC 1.3.6.1.4.1.13995.1.1.3.4.1.8
Mean BPC: sum of current bits configuration
OBJECT-TYPE    
  Integer32  

plInpNodeSNRChanges 1.3.6.1.4.1.13995.1.1.3.4.1.9
Changes of SNR
OBJECT-TYPE    
  Integer32  

plInpNodeSNR 1.3.6.1.4.1.13995.1.1.3.4.1.10
String with SNR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plInpNodeBPC 1.3.6.1.4.1.13995.1.1.3.4.1.11
String with BPC per carrier configuration: contains 256 bytes if it is a HE or 384 if it is a CPE.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plInpNodeCFR 1.3.6.1.4.1.13995.1.1.3.4.1.12
String with CFR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plInpNodeEnableCarriers 1.3.6.1.4.1.13995.1.1.3.4.1.13
String with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plInpNodeProtocolEnableCarriers 1.3.6.1.4.1.13995.1.1.3.4.1.14
String with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plInpNodeEnableProtocolEnableCarriers 1.3.6.1.4.1.13995.1.1.3.4.1.15
Enable protocol (1) and disable protocol (0).
OBJECT-TYPE    
  Integer32  

plTraps 1.3.6.1.4.1.13995.1.1.4
OBJECT IDENTIFIER    

plRemoteCPE 1.3.6.1.4.1.13995.1.1.5
OBJECT IDENTIFIER    

internal 1.3.6.1.4.1.13995.1.2
OBJECT IDENTIFIER    

amperionSystem 1.3.6.1.4.1.13995.2
OBJECT IDENTIFIER    

serialNumber 1.3.6.1.4.1.13995.2.1
The serial number of the board, which is unique per part number
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

partNumber 1.3.6.1.4.1.13995.2.2
The part number of the board, which identifies the board type
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

rombootVersion 1.3.6.1.4.1.13995.2.3
The string that identifies the Romboot software
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

alarms 1.3.6.1.4.1.13995.2.4
Dynamic alarm table - shows all the outstanding alarms on the system
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmsEntry

alarmsEntry 1.3.6.1.4.1.13995.2.4.1
Row of table alarms
OBJECT-TYPE    
  AlarmsEntry  

alarmIndex 1.3.6.1.4.1.13995.2.4.1.1
The alarmIndex uniquely identifies alarms on the system
OBJECT-TYPE    
  Integer32  

description 1.3.6.1.4.1.13995.2.4.1.2
Textual description of the alarm
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

productType 1.3.6.1.4.1.13995.2.5
injector/extractor/repeator
OBJECT-TYPE    
  INTEGER unknown(0), ohInjector(1), ohExtractor(2), ohRepeater(3), ohRepeaterExt(4), ugInjector(5), ugExtractor(6), ugRepeater(7), ugRepeaterExt(8)  

userGpsInfoString 1.3.6.1.4.1.13995.2.6
User defined string for the user to put the GPS info of this device
OBJECT-TYPE    
  DisplayString SIZE(1..128)  

linuxVersion 1.3.6.1.4.1.13995.2.8
The string that identifies the Linux kernel software
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

amperionSysDescr 1.3.6.1.4.1.13995.2.10
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

amperionSysObjectID 1.3.6.1.4.1.13995.2.11
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

amperionSysUpTime 1.3.6.1.4.1.13995.2.12
The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
OBJECT-TYPE    
  TimeTicks  

amperionSysContact 1.3.6.1.4.1.13995.2.13
The textual identification of the contact person for this managed node, together with information on how to contact this person.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

amperionSysName 1.3.6.1.4.1.13995.2.14
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

amperionSysLocation 1.3.6.1.4.1.13995.2.15
The physical location of this node (e.g., `telephone closet, 3rd floor').
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

amperionSysServices 1.3.6.1.4.1.13995.2.16
A value which indicates the set of services that this entity primarily offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs primarily routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., IP gateways) 4 end-to-end (e.g., IP hosts) 7 applications (e.g., mail relays) For systems including OSI protocols, layers 5 and 6 may also be counted.
OBJECT-TYPE    
  Integer32 0..127  

amperionTrapMgr1 1.3.6.1.4.1.13995.2.18
IP address of Manager receceiving traps
OBJECT-TYPE    
  IpAddress  

amperionTrapMgr2 1.3.6.1.4.1.13995.2.19
IP address of Manager receceiving traps
OBJECT-TYPE    
  IpAddress  

amperionTrapMgr3 1.3.6.1.4.1.13995.2.20
amperionTrapMgr3
OBJECT-TYPE    
  IpAddress  

softwareUpgrade 1.3.6.1.4.1.13995.3
OBJECT IDENTIFIER    

serverAddress 1.3.6.1.4.1.13995.3.1
Name or IP Address of the primary file server from which to retrieve new software.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

primaryPartitionContents 1.3.6.1.4.1.13995.3.2
Description of image in primary partition.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

currentState 1.3.6.1.4.1.13995.3.3
Current state of the software upgrade.
OBJECT-TYPE    
  INTEGER idle(1), inProgress(2)  

bootPartition 1.3.6.1.4.1.13995.3.4
Image in this partition will be used when the system boots.
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

upgradePartition 1.3.6.1.4.1.13995.3.5
Default partition to erase and load with a new image.
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

currentPartition 1.3.6.1.4.1.13995.3.6
Partition from which currently running software was loaded.
OBJECT-TYPE    
  INTEGER unknown(0), primary(1), backup(2)  

commandOptions 1.3.6.1.4.1.13995.3.7
Software upgrade options: Reserved for future use
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

backupPartitionContents 1.3.6.1.4.1.13995.3.8
Description of image in backup partition.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

primaryCRC 1.3.6.1.4.1.13995.3.9
CRC status of image in primary partition.
OBJECT-TYPE    
  INTEGER unknown(0), ok(1), failed(2)  

backupCRC 1.3.6.1.4.1.13995.3.10
CRC status of image in backup partition.
OBJECT-TYPE    
  INTEGER unknown(0), ok(1), failed(2)  

lastStatus 1.3.6.1.4.1.13995.3.11
Status of current or last software upgrade performed (since last reboot).
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

filename 1.3.6.1.4.1.13995.3.12
Path to filename to retrieve for software upgrade
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

server1Address 1.3.6.1.4.1.13995.3.13
Name or IP Address of the alternate file server from which to retrieve new software.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

server2Address 1.3.6.1.4.1.13995.3.14
Name or IP Address of the second alternate file server from which to retrieve new software.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

upgradeSchedule 1.3.6.1.4.1.13995.3.15
Scheduled upgrade date and time in MMDDhhmm format.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

rebootSchedule 1.3.6.1.4.1.13995.3.16
Scheduled reboot date and time in MMDDhhmm format.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

login 1.3.6.1.4.1.13995.3.17
login to use for software upgrade file server access.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

password 1.3.6.1.4.1.13995.3.18
password to use for software upgrade file server access.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

swupgradeCompleted 1.3.6.1.4.1.13995.3.19
swupgradeCompleted
NOTIFICATION-TYPE    
  backupPartitionContents  
  backupCRC  
  primaryPartitionContents  
  primaryCRC  
  bootPartition  

psGroup 1.3.6.1.4.1.13995.4
OBJECT IDENTIFIER    

acLineVoltage 1.3.6.1.4.1.13995.4.1
State of AC Line voltage (on/off)
OBJECT-TYPE    
  INTEGER off(0), on(1)  

plus12v 1.3.6.1.4.1.13995.4.2
Regulated 12 volt supply
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

minus8point5v 1.3.6.1.4.1.13995.4.3
Regulated -8.5 volt supply
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plus5v 1.3.6.1.4.1.13995.4.4
Regulated +5 volt supply
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

plus3point3v 1.3.6.1.4.1.13995.4.5
Regulated +3.3 volt supply
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

batteryCaseTemp 1.3.6.1.4.1.13995.4.6
Battery Case Temperature
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

internalMcuTemp 1.3.6.1.4.1.13995.4.7
Internal Micro Controller Unit Temperature
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

batteryCurrent 1.3.6.1.4.1.13995.4.8
Battery Current
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

batteryVoltage 1.3.6.1.4.1.13995.4.9
Battery Voltage
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

mcuSoftwareVersion 1.3.6.1.4.1.13995.4.10
Micro Controller Unit Software Version
OBJECT-TYPE    
  DisplayString SIZE(0..30)  

powerCycleNpu 1.3.6.1.4.1.13995.4.11
Power Cycle the Network Processor Unit
OBJECT-TYPE    
  INTEGER idle(0), commit(1)  

psMode 1.3.6.1.4.1.13995.4.12
Power Supply mode, normal mode is protocol; dump mode is a debug mode which displays debug prints from the MCU
OBJECT-TYPE    
  INTEGER protocol(0), dump(1)  

shutdownNpu 1.3.6.1.4.1.13995.4.13
Shut down 12v, -8.5v, 3.3v and 5v regulators driving the Network Processor Unit. This should only be used if one of the voltages is too high.
OBJECT-TYPE    
  INTEGER idle(0), commit(1)  

psImageChecksumError 1.3.6.1.4.1.13995.4.14
The power supply is notifying the main digital board that its main image crc is incorrect. The main digital board needs to reprogram the new power supply image again, or revert back to an older good image
NOTIFICATION-TYPE    
  eventDescription  

criticalBatteryShutdownWarning 1.3.6.1.4.1.13995.4.15
The power supply is warning the main digital board that we have lost AC Line voltage and the battery is running low. The system will be shutting down in seconds. Perform necessary backup.
NOTIFICATION-TYPE    
  eventDescription  

p12vOutOfRange 1.3.6.1.4.1.13995.4.16
The power supply is warning the main digital board that the +12v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware
NOTIFICATION-TYPE    
  eventDescription  

m8point5vOutOfRange 1.3.6.1.4.1.13995.4.17
The power supply is warning the main digital board that the -8.5v regulator is out of range. Note that the -8.5v regulator is the same regulator as the +12v. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
NOTIFICATION-TYPE    
  eventDescription  

p5vOutOfRange 1.3.6.1.4.1.13995.4.18
The power supply is warning the main digital board that the +5v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
NOTIFICATION-TYPE    
  eventDescription  

p3point3vOutOfRange 1.3.6.1.4.1.13995.4.19
The power supply is warning the main digital board that the +3.3v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
NOTIFICATION-TYPE    
  eventDescription  

batteryVoltsOutOfRange 1.3.6.1.4.1.13995.4.20
The power supply is warning the main digital board that the battery voltage is out of range.
NOTIFICATION-TYPE    
  eventDescription  

mcuTempOutOfRange 1.3.6.1.4.1.13995.4.21
The power supply is warning the main digital board that the microcontroller unit core temperature is out of range.
NOTIFICATION-TYPE    
  eventDescription  

batteryTempOutOfRange 1.3.6.1.4.1.13995.4.22
The power supply is warning the main digital board that the battery temperature is out of range
NOTIFICATION-TYPE    
  eventDescription  

psDetectedCommLapse 1.3.6.1.4.1.13995.4.23
Power Supply notifies main digital board that it did not communnicate to the power supply within the agreed upon periodic interval
NOTIFICATION-TYPE    
  eventDescription  

criticalRequestAborted 1.3.6.1.4.1.13995.4.24
The power supply is notifying the main digital board that one of the critical requests was aborted due to not receiving it twice in a row.
NOTIFICATION-TYPE    
  eventDescription  

powerSupplyInternalError 1.3.6.1.4.1.13995.4.25
Power Supply / netmgt (PS thread) detected an internal error condition
NOTIFICATION-TYPE    
  eventDescription  

psBatteryNotConnected 1.3.6.1.4.1.13995.4.26
Power Supply Battery Not Connected. There is no battery backup for the system.
NOTIFICATION-TYPE    
  eventDescription  

psAcOnOff 1.3.6.1.4.1.13995.4.27
Power Supply detected AC going ON / OFF
NOTIFICATION-TYPE    
  eventDescription  

psHardwareVersion 1.3.6.1.4.1.13995.4.28
Hardware Version of the Power SUpply
OBJECT-TYPE    
  DisplayString SIZE(0..30)  

psHardwareError 1.3.6.1.4.1.13995.4.29
The power supply is notifying the main digital board that it incurred a hardware error
NOTIFICATION-TYPE    
  eventDescription  

psEt 1.3.6.1.4.1.13995.4.30
Power Supply elapsed time since powerup
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

npuEt 1.3.6.1.4.1.13995.4.31
Power Supply elapsed time since powerup
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

npuPuTimes 1.3.6.1.4.1.13995.4.32
Number of times the Network Processing Unit has been powered up.
OBJECT-TYPE    
  Integer32  

eventDescription 1.3.6.1.4.1.13995.4.33
Description of the Last Event - Used in sending traps
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

npuDetectedCommLapse 1.3.6.1.4.1.13995.4.34
Network processing unit could not communnicate to the power supply
NOTIFICATION-TYPE    
  eventDescription  

amperionInterfaces 1.3.6.1.4.1.13995.5
OBJECT IDENTIFIER    

amperionifNumber 1.3.6.1.4.1.13995.5.1
The number of network interfaces (regardless of their current state) present on this system.
OBJECT-TYPE    
  Integer32  

amperionifTable 1.3.6.1.4.1.13995.5.2
A list of interface entries. The number of entries is given by the value of ifNumber.
OBJECT-TYPE    
  SEQUENCE OF  
    AmperionifEntry

amperionifEntry 1.3.6.1.4.1.13995.5.2.1
Row of table amperionifTable
OBJECT-TYPE    
  AmperionifEntry  

amperionWirelessActivate 1.3.6.1.4.1.13995.5.2.1.1
Command to activate 802.11 parameters on demand.
OBJECT-TYPE    
  TruthValue  

amperionifDescr 1.3.6.1.4.1.13995.5.2.1.2
A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the hardware interface.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

amperionifType 1.3.6.1.4.1.13995.5.2.1.3
The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack.
OBJECT-TYPE    
  INTEGER other(1), regular1822(2), hdh1822(3), ddnx25(4), rfc877x25(5), ethernetcsmacd(6), iso88023csmacd(7), iso88024tokenBus(8), iso88025tokenRing(9), iso88026man(10), starLan(11), proteon10Mbit(12), proteon80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), e1(19), basicISDN(20), primaryISDN(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet3Mbit(26), nsip(27), slip(28), ultra(29), ds3(30), sip(31), framerelay(32), ieee80211b(33), ieee80211a(34), ieee80211g(35)  

amperionifMtu 1.3.6.1.4.1.13995.5.2.1.4
The size of the largest datagram which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface.
OBJECT-TYPE    
  Integer32  

amperionifSpeed 1.3.6.1.4.1.13995.5.2.1.5
An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth.
OBJECT-TYPE    
  Gauge32  

amperionifPhysAddress 1.3.6.1.4.1.13995.5.2.1.6
The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

amperionifAdminStatus 1.3.6.1.4.1.13995.5.2.1.7
The desired state of the interface. The testing(3) state indicates that no operational packets can be passed.
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

amperionifOperStatus 1.3.6.1.4.1.13995.5.2.1.8
The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed.
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

amperionifLastChange 1.3.6.1.4.1.13995.5.2.1.9
The value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re- initialization of the local network management subsystem, then this object contains a zero value.
OBJECT-TYPE    
  TimeTicks  

amperionifInOctets 1.3.6.1.4.1.13995.5.2.1.10
The total number of octets received on the interface, including framing characters.
OBJECT-TYPE    
  Counter32  

amperionifInUcastPkts 1.3.6.1.4.1.13995.5.2.1.11
The number of subnetwork-unicast packets delivered to a higher-layer protocol.
OBJECT-TYPE    
  Counter32  

amperionifInNUcastPkts 1.3.6.1.4.1.13995.5.2.1.12
The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets delivered to a higher-layer protocol.
OBJECT-TYPE    
  Counter32  

amperionifInDiscards 1.3.6.1.4.1.13995.5.2.1.13
The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.
OBJECT-TYPE    
  Counter32  

amperionifInErrors 1.3.6.1.4.1.13995.5.2.1.14
The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.
OBJECT-TYPE    
  Counter32  

amperionifInUnknownProtos 1.3.6.1.4.1.13995.5.2.1.15
The number of packets received via the interface which were discarded because of an unknown or unsupported protocol.
OBJECT-TYPE    
  Counter32  

amperionifOutOctets 1.3.6.1.4.1.13995.5.2.1.16
The total number of octets transmitted out of the interface, including framing characters.
OBJECT-TYPE    
  Counter32  

amperionifOutUcastPkts 1.3.6.1.4.1.13995.5.2.1.17
The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent.
OBJECT-TYPE    
  Counter32  

amperionifOutNUcastPkts 1.3.6.1.4.1.13995.5.2.1.18
The total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent.
OBJECT-TYPE    
  Counter32  

amperionifOutDiscards 1.3.6.1.4.1.13995.5.2.1.19
The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space.
OBJECT-TYPE    
  Counter32  

amperionifOutErrors 1.3.6.1.4.1.13995.5.2.1.20
The number of outbound packets that could not be transmitted because of errors.
OBJECT-TYPE    
  Counter32  

amperionifOutQLen 1.3.6.1.4.1.13995.5.2.1.21
The length of the output packet queue (in packets).
OBJECT-TYPE    
  Gauge32  

amperionifSpecific 1.3.6.1.4.1.13995.5.2.1.22
A reference to MIB definitions specific to the particular media being used to realize the interface. For example, if the interface is realized by an ethernet, then the value of this object refers to a document defining objects specific to ethernet. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

amperionWirelessConfigEssid 1.3.6.1.4.1.13995.5.2.1.23
802.11 network name
OBJECT-TYPE    
  DisplayString SIZE(0..33)  

amperionWirelessConfigMode 1.3.6.1.4.1.13995.5.2.1.24
802.11 station operational mode
OBJECT-TYPE    
  INTEGER none(0), adhoc(1), managed(2), master(3), repeater(4)  

amperionWirelessConfigChanFreq 1.3.6.1.4.1.13995.5.2.1.25
802.11 Channel ID
OBJECT-TYPE    
  Unsigned32  

amperionWirelessConfigKey 1.3.6.1.4.1.13995.5.2.1.26
802.11 encryption or scrambling keys and encryption mode.
OBJECT-TYPE    
  DisplayString SIZE(0..33)  

amperionWirelessLinkQuality 1.3.6.1.4.1.13995.5.2.1.27
A measure of how good the received signal is.
OBJECT-TYPE    
  Unsigned32  

amperionWirelessSignalLevel 1.3.6.1.4.1.13995.5.2.1.28
Received signal strength (how strong the received signal is).
OBJECT-TYPE    
  Unsigned32  

amperionWirelessNoiseLevel 1.3.6.1.4.1.13995.5.2.1.29
Background noise level (when no packet is transmited).
OBJECT-TYPE    
  Unsigned32  

amperionWirelessConfigWifType 1.3.6.1.4.1.13995.5.2.1.30
802.11 protocol type.
OBJECT-TYPE    
  INTEGER wtype11a(1), wtype11b(2), wtype11g(3)  

amperionWirelessConfigBitRate 1.3.6.1.4.1.13995.5.2.1.31
The bit transmission rate in Megabits per second. (0 = autonegotiated)
OBJECT-TYPE    
  Integer32  

amperionWirelessConfigWDSPeer 1.3.6.1.4.1.13995.5.2.1.32
The MAC address of any WDS peer.
OBJECT-TYPE    
  DisplayString SIZE(0..80)  

interfaceAdminDown 1.3.6.1.4.1.13995.5.3
Admin of Interface being set down
NOTIFICATION-TYPE    
  amperionifDescr  

interfaceAdminUp 1.3.6.1.4.1.13995.5.4
Interface is being set up
NOTIFICATION-TYPE    
  amperionifDescr  

amperionWireless 1.3.6.1.4.1.13995.6
OBJECT IDENTIFIER    

accessControlStatus 1.3.6.1.4.1.13995.6.1
Status of the access control table
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

ampMacAcceptTable 1.3.6.1.4.1.13995.6.3
List of Mac address to be accepted
OBJECT-TYPE    
  SEQUENCE OF  
    AmpMacAcceptEntry

ampMacAcceptEntry 1.3.6.1.4.1.13995.6.3.1
Row of table ampMacAcceptTable
OBJECT-TYPE    
  AmpMacAcceptEntry  

macAcceptTableMacAddress 1.3.6.1.4.1.13995.6.3.1.1
Mac address to be accepted
OBJECT-TYPE    
  DisplayString SIZE(0..17)  

macAcceptTableRowStatus 1.3.6.1.4.1.13995.6.3.1.2
Row Status
OBJECT-TYPE    
  RowStatus  

macAcceptTableIndex 1.3.6.1.4.1.13995.6.3.1.3
Unique index
OBJECT-TYPE    
  Unsigned32 1..65536  

macAcceptTableWirelessIf 1.3.6.1.4.1.13995.6.3.1.4
The wireless interface (e.g. wlan0) that ACL table is applied to.
OBJECT-TYPE    
  Unsigned32  

amperionipAddrTable 1.3.6.1.4.1.13995.7
The table of addressing information relevant to this entity's IP addresses.
OBJECT-TYPE    
  SEQUENCE OF  
    AmperionipAddrEntry

amperionipAddrEntry 1.3.6.1.4.1.13995.7.1
Row of table amperionipAddrTable
OBJECT-TYPE    
  AmperionipAddrEntry  

amperionipAdEntAddr 1.3.6.1.4.1.13995.7.1.1
The IP address to which this entry's addressing information pertains.
OBJECT-TYPE    
  IpAddress  

amperionipAdEntIfName 1.3.6.1.4.1.13995.7.1.2
The name which uniquely identifies the interface to which this entry is applicable.
OBJECT-TYPE    
  DisplayString SIZE(1..80)  

amperionipAdEntNetMask 1.3.6.1.4.1.13995.7.1.3
The subnet mask associated with the IP address of this entry. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0.
OBJECT-TYPE    
  IpAddress  

amperionipAdEntBcastAddr 1.3.6.1.4.1.13995.7.1.4
The value of the least-significant bit in the IP broadcast address used for sending datagrams on the (logical) interface associated with the IP address of this entry. For example, when the Internet standard all-ones broadcast address is used, the value will be 1. This value applies to both the subnet and network broadcasts addresses used by the entity on this (logical) interface.
OBJECT-TYPE    
  Integer32  

amperionipAdEntReasmMaxSize 1.3.6.1.4.1.13995.7.1.5
The size of the largest IP datagram which this entity can re-assemble from incoming IP fragmented datagrams received on this interface.
OBJECT-TYPE    
  Integer32 0..65535  

amperionipAdRowStatus 1.3.6.1.4.1.13995.7.1.6
Row status
OBJECT-TYPE    
  RowStatus  

amperionipAdEntActivate 1.3.6.1.4.1.13995.7.1.7
Command to activate the new IP address/netmask on demand.
OBJECT-TYPE    
  TruthValue  

qualityOfService 1.3.6.1.4.1.13995.8
OBJECT IDENTIFIER    

serviceClassA 1.3.6.1.4.1.13995.8.1
Service Class A (Bandwidth in Kbps)
OBJECT-TYPE    
  Unsigned32 64..65536  

serviceClassB 1.3.6.1.4.1.13995.8.2
Service Class B (Bandwidth in Kbps)
OBJECT-TYPE    
  Unsigned32 64..65536  

serviceClassC 1.3.6.1.4.1.13995.8.3
Service Class C (Bandwidth in Kbps)
OBJECT-TYPE    
  Unsigned32 64..65536  

serviceClassD 1.3.6.1.4.1.13995.8.4
Service Class D (Bandwidth in Kbps)
OBJECT-TYPE    
  Unsigned32 64..65536  

subscriberTable 1.3.6.1.4.1.13995.8.5
List of subscribers
OBJECT-TYPE    
  SEQUENCE OF  
    SubscriberEntry

subscriberEntry 1.3.6.1.4.1.13995.8.5.1
Row of table subscriberTable
OBJECT-TYPE    
  SubscriberEntry  

index 1.3.6.1.4.1.13995.8.5.1.1
Subscriber unique identification
OBJECT-TYPE    
  Unsigned32 1..65536  

name 1.3.6.1.4.1.13995.8.5.1.2
Subscriber Name
OBJECT-TYPE    
  DisplayString SIZE(0..32)  

ipAddress 1.3.6.1.4.1.13995.8.5.1.3
Subscriber IP address
OBJECT-TYPE    
  IpAddress  

macAddress 1.3.6.1.4.1.13995.8.5.1.4
Subscriber MAC address
OBJECT-TYPE    
  DisplayString SIZE(0..17)  

serviceClass 1.3.6.1.4.1.13995.8.5.1.5
Subscriber Server Class
OBJECT-TYPE    
  INTEGER none(0), classA(1), classB(2), classC(3), classD(4)  

rowStatus 1.3.6.1.4.1.13995.8.5.1.6
A special field used to create new rows.
OBJECT-TYPE    
  RowStatus  

upstreamDownstreamRatio 1.3.6.1.4.1.13995.8.6
Upstream bandwidth to downstream bandwidth ratio
OBJECT-TYPE    
  DisplayString SIZE(1..32)  

qosStatus 1.3.6.1.4.1.13995.8.7
Enable or disable status of Qos
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

afe 1.3.6.1.4.1.13995.9
OBJECT IDENTIFIER    

afeExtractor 1.3.6.1.4.1.13995.9.1
OBJECT IDENTIFIER    

afeExtTxGain 1.3.6.1.4.1.13995.9.1.1
afeExtTxGain
OBJECT-TYPE    
  Integer32  

afeExtRxGain 1.3.6.1.4.1.13995.9.1.2
afeExtRxGain
OBJECT-TYPE    
  Integer32  

afeExtDownstream 1.3.6.1.4.1.13995.9.1.3
afeExtDownstream
OBJECT-TYPE    
  DisplayString SIZE(3..4)  

afeExtUpstream 1.3.6.1.4.1.13995.9.1.4
afeExtUpstream
OBJECT-TYPE    
  DisplayString SIZE(3..4)  

afeExtActivate 1.3.6.1.4.1.13995.9.1.5
afeExtActivate
OBJECT-TYPE    
  TruthValue  

afeInjector 1.3.6.1.4.1.13995.9.2
OBJECT IDENTIFIER    

afeInjTxGain 1.3.6.1.4.1.13995.9.2.1
afeInjTxGain
OBJECT-TYPE    
  Integer32  

afeInjRxGain 1.3.6.1.4.1.13995.9.2.2
afeInjRxGain
OBJECT-TYPE    
  Integer32  

afeInjDownstream 1.3.6.1.4.1.13995.9.2.3
afeInjDownstream
OBJECT-TYPE    
  DisplayString SIZE(3..4)  

afeInjUpstream 1.3.6.1.4.1.13995.9.2.4
afeInjUpstream
OBJECT-TYPE    
  DisplayString SIZE(3..4)  

afeInjActivate 1.3.6.1.4.1.13995.9.2.5
afeInjActivate
OBJECT-TYPE    
  TruthValue  

amperionRoutes 1.3.6.1.4.1.13995.10
OBJECT IDENTIFIER    

amperionRouteTable 1.3.6.1.4.1.13995.10.1
This entity's IP Routing table.
OBJECT-TYPE    
  SEQUENCE OF  
    AmperionRouteEntry

amperionRouteEntry 1.3.6.1.4.1.13995.10.1.1
Row of table amperionRouteTable
OBJECT-TYPE    
  AmperionRouteEntry  

ipRouteDest 1.3.6.1.4.1.13995.10.1.1.1
The destination IP address of this route. An entry with a value of 0.0.0.0 is considered a default route. Multiple routes to a single destination can appear in the table, but access to such multiple entries is dependent on the table- access mechanisms defined by the network management protocol in use.
OBJECT-TYPE    
  IpAddress  

ipRouteIfIndex 1.3.6.1.4.1.13995.10.1.1.2
The index value which uniquely identifies the local interface through which the next hop of this route should be reached. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
OBJECT-TYPE    
  Integer32  

ipRouteMetric1 1.3.6.1.4.1.13995.10.1.1.3
The primary routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
OBJECT-TYPE    
  Integer32  

ipRouteMetric2 1.3.6.1.4.1.13995.10.1.1.4
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
OBJECT-TYPE    
  Integer32  

ipRouteMetric3 1.3.6.1.4.1.13995.10.1.1.5
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
OBJECT-TYPE    
  Integer32  

ipRouteMetric4 1.3.6.1.4.1.13995.10.1.1.6
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
OBJECT-TYPE    
  Integer32  

ipRouteNextHop 1.3.6.1.4.1.13995.10.1.1.7
The IP address of the next hop of this route. (In the case of a route bound to an interface which is realized via a broadcast media, the value of this field is the agent's IP address on that interface.)
OBJECT-TYPE    
  IpAddress  

ipRouteType 1.3.6.1.4.1.13995.10.1.1.8
The type of route. Note that the values direct(3) and indirect(4) refer to the notion of direct and indirect routing in the IP architecture. Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the ipRouteTable object. That is, it effectively dissasociates the destination identified with said entry from the route identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ipRouteType object.
OBJECT-TYPE    
  INTEGER other(1), invalid(2), direct(3), indirect(4)  

ipRouteProto 1.3.6.1.4.1.13995.10.1.1.9
The routing mechanism via which this route was learned. Inclusion of values for gateway routing protocols is not intended to imply that hosts should support those protocols.
OBJECT-TYPE    
  INTEGER other(1), local(2), netmgt(3), icmp(4), egp(5), ggp(6), hello(7), rip(8), isis(9), esis(10), ciscoIgrp(11), bbnSpfIgp(12), ospf(13), bgp(14)  

ipRouteAge 1.3.6.1.4.1.13995.10.1.1.10
The number of seconds since this route was last updated or otherwise determined to be correct. Note that no semantics of `too old' can be implied except through knowledge of the routing protocol by which the route was learned.
OBJECT-TYPE    
  Integer32  

ipRouteMask 1.3.6.1.4.1.13995.10.1.1.11
Indicate the mask to be logical-ANDed with the destination address before being compared to the value in the ipRouteDest field. For those systems that do not support arbitrary subnet masks, an agent constructs the value of the ipRouteMask by determining whether the value of the correspondent ipRouteDest field belong to a class-A, B, or C network, and then using one of: mask network 255.0.0.0 class-A 255.255.0.0 class-B 255.255.255.0 class-C If the value of the ipRouteDest is 0.0.0.0 (a default route), then the mask value is also 0.0.0.0. It should be noted that all IP routing subsystems implicitly use this mechanism.
OBJECT-TYPE    
  IpAddress  

ipRouteMetric5 1.3.6.1.4.1.13995.10.1.1.12
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
OBJECT-TYPE    
  Integer32  

ipRouteInfo 1.3.6.1.4.1.13995.10.1.1.13
A reference to MIB definitions specific to the particular routing protocol which is responsible for this route, as determined by the value specified in the route's ipRouteProto value. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ipDefRouteActivate 1.3.6.1.4.1.13995.10.1.1.14
Command to activate the new default route.
OBJECT-TYPE    
  TruthValue  

plc 1.3.6.1.4.1.13995.11
OBJECT IDENTIFIER    

plcExtractor 1.3.6.1.4.1.13995.11.1
OBJECT IDENTIFIER    

plcExtTxGain 1.3.6.1.4.1.13995.11.1.1
plcExtTxGain
OBJECT-TYPE    
  Integer32 0..10  

plcExtRxGain 1.3.6.1.4.1.13995.11.1.2
plcExtRxGain
OBJECT-TYPE    
  Integer32 0..10  

plcInjector 1.3.6.1.4.1.13995.11.2
OBJECT IDENTIFIER    

plcInjTxGain 1.3.6.1.4.1.13995.11.2.1
plcInjTxGain
OBJECT-TYPE    
  Integer32 0..10  

plcInjRxGain 1.3.6.1.4.1.13995.11.2.2
plcInjRxGain
OBJECT-TYPE    
  Integer32 0..10  

plcUp 1.3.6.1.4.1.13995.11.3
Extractor's PLC interface came up
NOTIFICATION-TYPE    
  plcEventDescription  

plcDown 1.3.6.1.4.1.13995.11.4
Extractor's PLC interface went down
NOTIFICATION-TYPE    
  plcEventDescription  

afeCpldResetCount 1.3.6.1.4.1.13995.11.5
afe Cpld Reset Count
OBJECT-TYPE    
  Counter32  

plcLossCount 1.3.6.1.4.1.13995.11.6
plc Loss Count
OBJECT-TYPE    
  Counter32  

resetCounters 1.3.6.1.4.1.13995.11.7
reset Counters
OBJECT-TYPE    
  INTEGER idle(1), reset(2)  

optimizationTable 1.3.6.1.4.1.13995.11.8
If Injector - This table contains the frequencies(channels) / gains / throughput of all the extractors down stream. If Extractor - This table should contain frequencies(channels) / gains / throughput for the the plc segment between this extractor and the injector/repeator upstream.
OBJECT-TYPE    
  SEQUENCE OF  
    OptimizationEntry

optimizationEntry 1.3.6.1.4.1.13995.11.8.1
Row of table optimizationTable
OBJECT-TYPE    
  OptimizationEntry  

extrIpaddress 1.3.6.1.4.1.13995.11.8.1.1
extractor's ipaddress
OBJECT-TYPE    
  IpAddress  

extrChannelNumber 1.3.6.1.4.1.13995.11.8.1.2
Extractor Channel Number
OBJECT-TYPE    
  Integer32  

upstreamFreq 1.3.6.1.4.1.13995.11.8.1.3
Upstream Frequency
OBJECT-TYPE    
  DisplayString  

downstreamFreq 1.3.6.1.4.1.13995.11.8.1.4
Downstream Frequency
OBJECT-TYPE    
  DisplayString  

rxGain 1.3.6.1.4.1.13995.11.8.1.5
rxGain setting
OBJECT-TYPE    
  DisplayString  

txGain 1.3.6.1.4.1.13995.11.8.1.6
Tx Gain Setting
OBJECT-TYPE    
  DisplayString  

plcThroughput 1.3.6.1.4.1.13995.11.8.1.7
plcThroughput
OBJECT-TYPE    
  DisplayString  

upStreamDownStream 1.3.6.1.4.1.13995.11.8.1.8
This to indicate if this entry pertains to the upstream segment or the downstream segment
OBJECT-TYPE    
  INTEGER upstream(1), downstream(2), unknown(3)  

gpsInfo 1.3.6.1.4.1.13995.11.8.1.9
GPS co-ordinates. Currently this is a string which means the machine just picks up whatever GPS info is defined in it's system group and sends it to the extractor
OBJECT-TYPE    
  DisplayString SIZE(1..128)  

plcEventDescription 1.3.6.1.4.1.13995.11.9
String to be sent in the plc up/down event. Will contain ip address of the unit which just went down or will say 'local system' if current system
OBJECT-TYPE    
  DisplayString SIZE(1..128)  

tempGroup 1.3.6.1.4.1.13995.12
OBJECT IDENTIFIER    

tempFanState 1.3.6.1.4.1.13995.12.1
The fans may be on or off.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

tempFanTargetTemp 1.3.6.1.4.1.13995.12.2
The target temperature is the average temperature we would like the system to operate at if possible. It is used to calculate how long the fans should stay on during a cycle which is part of a duty cycle algorithm. Temperature is in degrees celsius.
OBJECT-TYPE    
  Integer32 0..70  

tempHighWarnLimit 1.3.6.1.4.1.13995.12.3
The system temperature has exceeded a high temperature warning threshold. Temperature is in degrees Celsius.
OBJECT-TYPE    
  Integer32 0..150  

tempHighWarnLimitTrap 1.3.6.1.4.1.13995.12.4
The system temperature has exceeded the High Warning threshold.
NOTIFICATION-TYPE    
  tempEventDescription  
  tempHighWarnLimit  
  tempSystemTemp  

tempEventDescription 1.3.6.1.4.1.13995.12.5
String to be sent with the temperature trap events.
OBJECT-TYPE    
  DisplayString SIZE(1..130)  

tempHighErrorLimitTrap 1.3.6.1.4.1.13995.12.6
The system temperature has exceeded the High Error Threshold.
NOTIFICATION-TYPE    
  tempEventDescription  
  tempHighErrorLimit  
  tempSystemTemp  

tempLowWarnLimitTrap 1.3.6.1.4.1.13995.12.7
The system temperature has gone below the Low Warning Threshold.
NOTIFICATION-TYPE    
  tempEventDescription  
  tempLowWarnLimit  
  tempSystemTemp  

tempLowErrorLimitTrap 1.3.6.1.4.1.13995.12.8
The system temperature has gone below the Low Error Threshold.
NOTIFICATION-TYPE    
  tempEventDescription  
  tempLowErrorLimit  
  tempSystemTemp  

tempHighErrorLimit 1.3.6.1.4.1.13995.12.9
The system temperature has exceeded a high temperature error threshold. Temperature is in degrees Celsius.
OBJECT-TYPE    
  Integer32 0..150  

tempLowWarnLimit 1.3.6.1.4.1.13995.12.10
The system temperature has gone below a low temperature warning threshold. Temperature is in degrees Celscius.
OBJECT-TYPE    
  Integer32 -100..60  

tempLowErrorLimit 1.3.6.1.4.1.13995.12.11
The system temperature has gone below the Low Temperature Error Threshold. The temperature is in degrees Celscius.
OBJECT-TYPE    
  Integer32 -100..60  

tempHighWarnHist 1.3.6.1.4.1.13995.12.12
Hysteresis value for the High Temperature Warning Condition. Once the system temperature has reached or exceeded the High Temperature Warning threshold, it must go down to or below the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
OBJECT-TYPE    
  Integer32 -10..150  

tempHighErrorHist 1.3.6.1.4.1.13995.12.13
Hysteresis value for the High Temperature Error Condition. Once the system temperature has reached or exceeded the High Temperature Error Threshold, it must go down to or below the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
OBJECT-TYPE    
  Integer32 -10..150  

tempLowWarnHist 1.3.6.1.4.1.13995.12.14
Hysteresis value for the Low Temperature Warning Condition. Once the system temperature is less than or equal to the LowTemperature Warning threshold, it must go up to or above the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
OBJECT-TYPE    
  Integer32 -100..60  

tempLowErrorHist 1.3.6.1.4.1.13995.12.15
Hysteresis value for the Low Temperature Error Condition. Once the system temperature is less than or equal to the LowTemperature Error threshold, it must go up to or above the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
OBJECT-TYPE    
  Integer32 -100..60  

tempSystemTemp 1.3.6.1.4.1.13995.12.16
The temperature of the Main Digital Board. The temperature is obtained by reading a chip located on the digital board.
OBJECT-TYPE    
  Integer32  

Defined Objects

PlCdEntry  
SEQUENCE    
  Integer32 as plCdIndex  
  INTEGER as plCdType  
  INTEGER as plCdLink  
  Integer32 as plCdShortMacAddress  
  DisplayString as plCdLongMacAddress  
  DisplayString as plCdHardwareVersion  
  DisplayString as plCdFirmwareVersion  
  DisplayString as plCdDriverVersion  
  Integer32 as plCdReset  
  Integer32 as plCdFactoryReset  
  Integer32 as plCdSaveAsPermanent  
  Integer32 as plCdStatus  
  DisplayString as plCdRemoteList  
  Integer32 as plCdNumRemoteList  

PlNetEntry  
SEQUENCE    
  Integer32 as plNetShortMacAddress  
  DisplayString as plNetLongMacAddress  
  RowStatus as plNetRowStatus  

PlInpEntry  
SEQUENCE    
  Integer32 as plInpTotalOctets  
  Integer32 as plInpGain  
  INTEGER as plInpAGC  
  Integer32 as plInpMaxGain  
  DisplayString as plInpThresholds  
  Integer32 as plInpAttenuationGain  
  Integer32 as plInpSamsDecode  
  Integer32 as plInpSamsGood  
  Integer32 as plInpSamsBad  

PlInpNodeEntry  
SEQUENCE    
  Integer32 as plInpNodeReceivedPkts  
  Integer32 as plInpNodeReceivedUnrecPkts  
  Integer32 as plInpNodeReceivedCorrectedPkts  
  Integer32 as plInpNodeReceivedOctets  
  Integer32 as plInpNodeReceivedCorrectedOctets  
  Integer32 as plInpNodeReceivedPower  
  Integer32 as plInpNodePLR  
  Integer32 as plInpNodeMeanBPC  
  Integer32 as plInpNodeSNRChanges  
  DisplayString as plInpNodeSNR  
  DisplayString as plInpNodeBPC  
  DisplayString as plInpNodeCFR  
  DisplayString as plInpNodeEnableCarriers  
  DisplayString as plInpNodeProtocolEnableCarriers  
  Integer32 as plInpNodeEnableProtocolEnableCarriers  

AlarmsEntry  
SEQUENCE    
  Integer32 as alarmIndex  
  DisplayString as description  

AmperionifEntry  
SEQUENCE    
  DisplayString as amperionifDescr  
  INTEGER as amperionifType  
  Integer32 as amperionifMtu  
  Gauge32 as amperionifSpeed  
  DisplayString as amperionifPhysAddress  
  INTEGER as amperionifAdminStatus  
  INTEGER as amperionifOperStatus  
  TimeTicks as amperionifLastChange  
  Counter32 as amperionifInOctets  
  Counter32 as amperionifInUcastPkts  
  Counter32 as amperionifInNUcastPkts  
  Counter32 as amperionifInDiscards  
  Counter32 as amperionifInErrors  
  Counter32 as amperionifInUnknownProtos  
  Counter32 as amperionifOutOctets  
  Counter32 as amperionifOutUcastPkts  
  Counter32 as amperionifOutNUcastPkts  
  Counter32 as amperionifOutDiscards  
  Counter32 as amperionifOutErrors  
  Gauge32 as amperionifOutQLen  
  OBJECT IDENTIFIER as amperionifSpecific  
  DisplayString as amperionWirelessConfigEssid  
  INTEGER as amperionWirelessConfigMode  
  Unsigned32 as amperionWirelessConfigChanFreq  
  DisplayString as amperionWirelessConfigKey  
  INTEGER as amperionWirelessConfigWifType  
  Unsigned32 as amperionWirelessLinkQuality  
  Unsigned32 as amperionWirelessSignalLevel  
  Unsigned32 as amperionWirelessNoiseLevel  
  TruthValue as amperionWirelessActivate  
  Integer32 as amperionWirelessConfigBitRate  
  DisplayString as amperionWirelessConfigWDSPeer  

AmpMacAcceptEntry  
SEQUENCE    
  Unsigned32 as macAcceptTableIndex  
  RowStatus as macAcceptTableRowStatus  
  DisplayString as macAcceptTableMacAddress  
  Unsigned32 as macAcceptTableWirelessIf  

AmperionipAddrEntry  
SEQUENCE    
  IpAddress as amperionipAdEntAddr  
  DisplayString as amperionipAdEntIfName  
  IpAddress as amperionipAdEntNetMask  
  Integer32 as amperionipAdEntBcastAddr  
  Integer32 as amperionipAdEntReasmMaxSize  
  TruthValue as amperionipAdEntActivate  
  RowStatus as amperionipAdRowStatus  

SubscriberEntry  
SEQUENCE    
  Unsigned32 as index  
  DisplayString as name  
  IpAddress as ipAddress  
  DisplayString as macAddress  
  INTEGER as serviceClass  
  RowStatus as rowStatus  

AmperionRouteEntry  
SEQUENCE    
  IpAddress as ipRouteDest  
  Integer32 as ipRouteIfIndex  
  Integer32 as ipRouteMetric1  
  Integer32 as ipRouteMetric2  
  Integer32 as ipRouteMetric3  
  Integer32 as ipRouteMetric4  
  IpAddress as ipRouteNextHop  
  INTEGER as ipRouteType  
  INTEGER as ipRouteProto  
  Integer32 as ipRouteAge  
  IpAddress as ipRouteMask  
  Integer32 as ipRouteMetric5  
  OBJECT IDENTIFIER as ipRouteInfo  
  TruthValue as ipDefRouteActivate  

OptimizationEntry  
SEQUENCE    
  IpAddress as extrIpaddress  
  Integer32 as extrChannelNumber  
  DisplayString as upstreamFreq  
  DisplayString as downstreamFreq  
  DisplayString as rxGain  
  DisplayString as txGain  
  DisplayString as plcThroughput  
  INTEGER as upStreamDownStream  
  DisplayString as gpsInfo