| SNMPv2-TC | RFC1155-SMI | RFC-1212 |
| RFC1213-MIB | RFC-1215 |
| DisplayString | Counter | OBJECT-TYPE |
| sysDescr | sysName | TRAP-TYPE |
| org | 1.3 | ||
| OBJECT IDENTIFIER | |||
| dod | 1.3.6 | ||
| OBJECT IDENTIFIER | |||
| internet | 1.3.6.1 | ||
| OBJECT IDENTIFIER | |||
| private | 1.3.6.1.4 | ||
| OBJECT IDENTIFIER | |||
| enterprises | 1.3.6.1.4.1 | ||
| OBJECT IDENTIFIER | |||
| bintec | 1.3.6.1.4.1.272 | ||
| OBJECT IDENTIFIER | |||
| bibo | 1.3.6.1.4.1.272.4 | ||
| OBJECT IDENTIFIER | |||
| sys | 1.3.6.1.4.1.272.4.17 | ||
| OBJECT IDENTIFIER | |||
| x4 | 1.3.6.1.4.1.272.4.17.2 | ||
| OBJECT IDENTIFIER | |||
| sysX4Config | 1.3.6.1.4.1.272.4.17.2.1 | ||
| OBJECT IDENTIFIER | |||
| sysX4ConfigLcdBrightness | 1.3.6.1.4.1.272.4.17.2.1.1 | ||
| This variable allows to control the brightness of the LCD display. Lower values mean less, higher values mean more brightness. Zero means no brightness. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..3 | ||
| sysX4ConfigLcdContrast | 1.3.6.1.4.1.272.4.17.2.1.2 | ||
| This variable allows to control the contrast of the LCD display. Lower values mean less, higher values mean more contrast. Zero means factory settings. | |||
| OBJECT-TYPE | |||
| INTEGER | 0..10 | ||
| sysX4ConfigLcdConfigure | 1.3.6.1.4.1.272.4.17.2.1.3 | ||
| This variable determines whether it is possible to configure the brick by using the LCD display and the buttons. | |||
| OBJECT-TYPE | |||
| INTEGER | off(1), on(2) | ||
| sysX4ConfigLcdPin | 1.3.6.1.4.1.272.4.17.2.1.4 | ||
| The PIN is the personal identification number that is needed for authorisation for display configurations. It consists solely of digits and must be 4 characters long. Default Value is '0000'. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(4..4) | ||
| sysX4ConfigLcdIdleTimer | 1.3.6.1.4.1.272.4.17.2.1.5 | ||
| After this time the display screen changes to default screen. Default Value is 5. If this value is set to 0, change to defaultscreen is disabled | |||
| OBJECT-TYPE | |||
| INTEGER | 0..5 | ||
| sysX4ConfigLcdDefaultScreen | 1.3.6.1.4.1.272.4.17.2.1.6 | ||
| This screen will be displayed after the LcdIdleTimer has elapsed. Default Value is MainMenu. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..8) | ||
| sysX4ConfigLcdLanguage | 1.3.6.1.4.1.272.4.17.2.1.7 | ||
| Choose your display language. | |||
| OBJECT-TYPE | |||
| DisplayString | SIZE(0..20) | ||
| sysX4ConfigTempUnit | 1.3.6.1.4.1.272.4.17.2.1.8 | ||
| This variable defines the unit of sysX4Config*Temp, either Celsius or Fahrenheit. | |||
| OBJECT-TYPE | |||
| INTEGER | celsius(1), fahrenheit(2) | ||
| sysX4ConfigMainTemp | 1.3.6.1.4.1.272.4.17.2.1.9 | ||
| This variable shows the actual main board temperature measured in the units Fahrenheit or Celsius. | |||
| OBJECT-TYPE | |||
| INTEGER | -1000..1000 | ||
| sysX4ConfigMainTempAlarmThreshold | 1.3.6.1.4.1.272.4.17.2.1.10 | ||
| system mainboard temperature threshold. | |||
| OBJECT-TYPE | |||
| INTEGER | -1000..1000 | ||
| sysX4ConfigMainTempAlarmTrap | 1.3.6.1.4.1.272.4.17.2.1.11 | ||
| If the system temperature raises above the threshold, a alarm trap is generated every 60 seconds. | |||
| OBJECT-TYPE | |||
| INTEGER | normal(1), critical(2) | ||
| sysX4ConfigMod1Temp | 1.3.6.1.4.1.272.4.17.2.1.12 | ||
| This variable shows the actual module sensor1 temperature in the units Fahrenheit or Celsius. | |||
| OBJECT-TYPE | |||
| INTEGER | -1000..1000 | ||
| sysX4ConfigMod1TempAlarmThreshold | 1.3.6.1.4.1.272.4.17.2.1.13 | ||
| actual module sensor1 temperature threshold. | |||
| OBJECT-TYPE | |||
| INTEGER | -1000..1000 | ||
| sysX4ConfigMod1TempAlarmTrap | 1.3.6.1.4.1.272.4.17.2.1.14 | ||
| If the actual module sensor1 temperature raises above the threshold, a alarm trap is generated every 60 seconds. | |||
| OBJECT-TYPE | |||
| INTEGER | normal(1), critical(2) | ||
| sysX4ConfigMod2Temp | 1.3.6.1.4.1.272.4.17.2.1.15 | ||
| This variable shows the actual module sensor2 temperature in the units Fahrenheit or Celsius. | |||
| OBJECT-TYPE | |||
| INTEGER | -1000..1000 | ||
| sysX4ConfigMod2TempAlarmThreshold | 1.3.6.1.4.1.272.4.17.2.1.16 | ||
| actual module sensor2 temperature threshold. | |||
| OBJECT-TYPE | |||
| INTEGER | -1000..1000 | ||
| sysX4ConfigMod2TempAlarmTrap | 1.3.6.1.4.1.272.4.17.2.1.17 | ||
| If the actual module sensor2 temperature raises above the threshold, a alarm trap is generated every 60 seconds. | |||
| OBJECT-TYPE | |||
| INTEGER | normal(1), critical(2) | ||
| sysX4Traps | 1.3.6.1.4.1.272.4.17.2.2 | ||
| OBJECT IDENTIFIER | |||
| sysX4TrapMainTempCritical | 1.3.6.1.4.1.272.4.17.2.2.1 | ||
| This trap signifies that the system board temperature raises above the critical alarm-threshold | |||
| TRAP-TYPE | |||
| sysDescr | |||
| sysName | |||
| sysX4ConfigTempUnit | |||
| sysX4ConfigMainTemp | |||
| sysX4ConfigMainTempAlarmThreshold | |||
| sysX4ConfigMod1Temp | |||
| sysX4ConfigMod2Temp | |||
| sysX4TrapMainTempOk | 1.3.6.1.4.1.272.4.17.2.2.2 | ||
| Normal system board temperature has been restored. | |||
| TRAP-TYPE | |||
| sysDescr | |||
| sysName | |||
| sysX4ConfigTempUnit | |||
| sysX4ConfigMainTemp | |||
| sysX4ConfigMainTempAlarmThreshold | |||
| sysX4ConfigMod1Temp | |||
| sysX4ConfigMod2Temp | |||
| sysX4TrapMod1TempCritical | 1.3.6.1.4.1.272.4.17.2.2.3 | ||
| This trap signifies that the actual module (sensor 1) temperature raises above the critical alarm-threshold | |||
| TRAP-TYPE | |||
| sysDescr | |||
| sysName | |||
| sysX4ConfigTempUnit | |||
| sysX4ConfigMainTemp | |||
| sysX4ConfigMod1Temp | |||
| sysX4ConfigMod1TempAlarmThreshold | |||
| sysX4ConfigMod2Temp | |||
| sysX4TrapMod1Temp1Ok | 1.3.6.1.4.1.272.4.17.2.2.4 | ||
| Normal temperature of actual module (sensor 1) has been restored. | |||
| TRAP-TYPE | |||
| sysDescr | |||
| sysName | |||
| sysX4ConfigTempUnit | |||
| sysX4ConfigMainTemp | |||
| sysX4ConfigMod1Temp | |||
| sysX4ConfigMod1TempAlarmThreshold | |||
| sysX4ConfigMod2Temp | |||
| sysX4TrapMod2TempCritical | 1.3.6.1.4.1.272.4.17.2.2.5 | ||
| This trap signifies that the actual module (sensor 2) temperature raises above the critical alarm-threshold | |||
| TRAP-TYPE | |||
| sysDescr | |||
| sysName | |||
| sysX4ConfigTempUnit | |||
| sysX4ConfigMainTemp | |||
| sysX4ConfigMod1Temp | |||
| sysX4ConfigMod2Temp | |||
| sysX4ConfigMod2TempAlarmThreshold | |||
| sysX4TrapMod2TempOk | 1.3.6.1.4.1.272.4.17.2.2.6 | ||
| Normal temperature of actual module (sensor 2) has been restored. | |||
| TRAP-TYPE | |||
| sysDescr | |||
| sysName | |||
| sysX4ConfigTempUnit | |||
| sysX4ConfigMainTemp | |||
| sysX4ConfigMod1Temp | |||
| sysX4ConfigMod2Temp | |||
| sysX4ConfigMod2TempAlarmThreshold | |||