BLADESPPALT-MIB

File: BLADESPPALT-MIB.mib (37345 bytes)

Imported modules

RFC-1212 RFC1155-SMI RFC1213-MIB
RFC-1215

Imported symbols

OBJECT-TYPE enterprises DisplayString
TRAP-TYPE

Defined Objects

ibm 1.3.6.1.4.1.2
OBJECT IDENTIFIER    

ibmProd 1.3.6.1.4.1.2.6
OBJECT IDENTIFIER    

supportProcessor 1.3.6.1.4.1.2.6.158
OBJECT IDENTIFIER    

mmRemoteSupTrapMIB 1.3.6.1.4.1.2.6.158.3
OBJECT IDENTIFIER    

mmTrapTempC 1.3.6.1.4.1.2.6.158.3.0
Critical Alert: Temperature threshold exceeded.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

remoteSupTrapMibObjects 1.3.6.1.4.1.2.6.158.3.1
OBJECT IDENTIFIER    

mmTrapVoltC 1.3.6.1.4.1.2.6.158.3.1
Critical Alert: Voltage threshold exceeded.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

spTrapInfo 1.3.6.1.4.1.2.6.158.3.1.1
OBJECT IDENTIFIER    

spTrapDateTime 1.3.6.1.4.1.2.6.158.3.1.1.1
Timestamp of Local Date and Time when alert was generated
OBJECT-TYPE    
  DisplayString  

spTrapAppId 1.3.6.1.4.1.2.6.158.3.1.1.2
Application ID, always 'BladeCenter Management Module'
OBJECT-TYPE    
  DisplayString  

spTrapSpTxtId 1.3.6.1.4.1.2.6.158.3.1.1.3
SP System Identification - Text Identification
OBJECT-TYPE    
  DisplayString  

spTrapSysUuid 1.3.6.1.4.1.2.6.158.3.1.1.4
Host System UUID(Universal Unique ID)
OBJECT-TYPE    
  DisplayString  

spTrapSysSern 1.3.6.1.4.1.2.6.158.3.1.1.5
Host System Serial Number
OBJECT-TYPE    
  DisplayString  

spTrapAppType 1.3.6.1.4.1.2.6.158.3.1.1.6
Application Alert Type - Event Number ID
OBJECT-TYPE    
  INTEGER 1..65535  

spTrapPriority 1.3.6.1.4.1.2.6.158.3.1.1.7
Alert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery Alert(8) - Informational Only Alert(255)
OBJECT-TYPE    
  INTEGER 1..65535  

spTrapMsgText 1.3.6.1.4.1.2.6.158.3.1.1.8
Alert Message Text
OBJECT-TYPE    
  DisplayString  

spTrapHostContact 1.3.6.1.4.1.2.6.158.3.1.1.9
Host Contact
OBJECT-TYPE    
  DisplayString  

spTrapHostLocation 1.3.6.1.4.1.2.6.158.3.1.1.10
Host Location
OBJECT-TYPE    
  DisplayString  

spTrapBladeName 1.3.6.1.4.1.2.6.158.3.1.1.11
Blade Name
OBJECT-TYPE    
  DisplayString  

spTrapBladeSern 1.3.6.1.4.1.2.6.158.3.1.1.12
Blade Serial Number
OBJECT-TYPE    
  DisplayString  

spTrapBladeUuid 1.3.6.1.4.1.2.6.158.3.1.1.13
Blade UUID(Universal Unique ID)
OBJECT-TYPE    
  DisplayString  

mmTrapTampC 1.3.6.1.4.1.2.6.158.3.2
Critical Alert: Physical intrusion of system has occurred.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapMffC 1.3.6.1.4.1.2.6.158.3.3
Critical Alert: Multiple fan failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapPsC 1.3.6.1.4.1.2.6.158.3.4
Critical Alert: Power supply failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mTrapHdC 1.3.6.1.4.1.2.6.158.3.5
Critical Alert: Hard disk drive failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapVrmC 1.3.6.1.4.1.2.6.158.3.6
Critical Alert: Voltage Regulator Module(VRM) failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapRdpsN 1.3.6.1.4.1.2.6.158.3.10
Non-Critical Alert: Redundant Power Supply failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapSffC 1.3.6.1.4.1.2.6.158.3.11
Critical Alert: Single Fan failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapTempN 1.3.6.1.4.1.2.6.158.3.12
Non-Critical Alert: Temperature threshold exceeded.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapVoltN 1.3.6.1.4.1.2.6.158.3.13
Non-Critical Alert: Voltage threshold exceeded.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapSecDvS 1.3.6.1.4.1.2.6.158.3.15
System Alert: Secondary Device warning.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapPostToS 1.3.6.1.4.1.2.6.158.3.20
System Alert: Post Timeout value exceeded.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapOsToS 1.3.6.1.4.1.2.6.158.3.21
System Alert: OS Timeout value exceeded.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapAppS 1.3.6.1.4.1.2.6.158.3.22
System Alert: Application Alert.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapPoffS 1.3.6.1.4.1.2.6.158.3.23
System Alert: Power Off.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapPonS 1.3.6.1.4.1.2.6.158.3.24
System Alert: Power On.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapBootS 1.3.6.1.4.1.2.6.158.3.25
System Alert: System Boot Failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapLdrToS 1.3.6.1.4.1.2.6.158.3.26
System Alert: OS Loader Timeout.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapPFAS 1.3.6.1.4.1.2.6.158.3.27
System Alert: Predictive Failure Analysis(PFA) information.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapMsC 1.3.6.1.4.1.2.6.158.3.31
Critical Alert: Multiple switch module failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapRmN 1.3.6.1.4.1.2.6.158.3.32
Non-Critical Alert: Redundant module.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapKVMSwitchS 1.3.6.1.4.1.2.6.158.3.33
System Alert: Keyboard/Video/Mouse(KVM) or Medial Tray(MT) switching failure.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapSysInvS 1.3.6.1.4.1.2.6.158.3.34
System Alert: Inventory.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapSysLogS 1.3.6.1.4.1.2.6.158.3.35
System Alert: System Log 75% full.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapIhcC 1.3.6.1.4.1.2.6.158.3.36
Critical Alert: Incompatible hardware configuration.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapNwChangeS 1.3.6.1.4.1.2.6.158.3.37
System Alert: Network change notification.
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapBlThrS 1.3.6.1.4.1.2.6.158.3.39
System Alert: Blade Throttle
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid  

mmTrapPwrMgntS 1.3.6.1.4.1.2.6.158.3.40
System Alert: Power Management
TRAP-TYPE    
  spTrapDateTime  
  spTrapAppId  
  spTrapSpTxtId  
  spTrapSysUuid  
  spTrapSysSern  
  spTrapAppType  
  spTrapPriority  
  spTrapMsgText  
  spTrapHostContact  
  spTrapHostLocation  
  spTrapBladeName  
  spTrapBladeSern  
  spTrapBladeUuid