BW-BroadworksDiameterFrontNodeFault

File: BW-BroadworksDiameterFrontNodeFault.mib (3097 bytes)

Imported modules

SNMPv2-SMI BroadworksFault

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE common
faultFields identifier timeStamp
alarmName systemName severity
alarmState component subcomponent
problemText recommendedActionsText

Defined Objects

systemFaults 1.3.6.1.4.1.6431.1.1.1
The defines the fault for the BroadWorks Diameter Server interconnect process.
MODULE-IDENTITY    

bwPMDiameterFrontNodeLaunched 1.3.6.1.4.1.6431.1.1.1.5101
Indicates that the Diameter Front Node has been started. For a complete description, refer the BroadWorks FaultManagementGuide as it may contain variable data.
NOTIFICATION-TYPE    
  identifier  
  timeStamp  
  alarmName  
  systemName  
  severity  
  component  
  subcomponent  
  problemText  
  recommendedActionsText  

bwPMDiameterFrontNodeShutDown 1.3.6.1.4.1.6431.1.1.1.5102
Indicates that the Diameter Front Node has been manually shut down. For a complete description, refer the BroadWorks FaultManagementGuide as it may contain variable data.
NOTIFICATION-TYPE    
  identifier  
  timeStamp  
  alarmName  
  systemName  
  severity  
  component  
  subcomponent  
  problemText  
  recommendedActionsText  

bwPMDiameterFrontNodeRestarted 1.3.6.1.4.1.6431.1.1.1.5103
Indicates that the Diameter Front Node has been restarted. For a complete description, refer the BroadWorks FaultManagementGuide as it may contain variable data.
NOTIFICATION-TYPE    
  identifier  
  timeStamp  
  alarmName  
  systemName  
  severity  
  component  
  subcomponent  
  problemText  
  recommendedActionsText  

bwPMDiameterFrontNodeDeath 1.3.6.1.4.1.6431.1.1.1.5104
Indicates that the Diameter Front Node has terminated. For a complete description, refer the BroadWorks FaultManagementGuide as it may contain variable data.
NOTIFICATION-TYPE    
  identifier  
  timeStamp  
  alarmName  
  systemName  
  severity  
  component  
  subcomponent  
  problemText  
  recommendedActionsText  

bwDiameterFrontNodeSyncFailure 1.3.6.1.4.1.6431.1.1.1.5105
Indicates that the Execution Server encountered a failure messaging with the Diameter Front Node when synchronizing Diameter Front Node configuration data with the database. For a complete description, refer the BroadWorks FaultManagementGuide as it may contain variable data.
NOTIFICATION-TYPE    
  identifier  
  timeStamp  
  alarmName  
  systemName  
  severity  
  component  
  subcomponent  
  problemText  
  recommendedActionsText