CERENT-454-MIB

File: CERENT-454-MIB.mib (168015 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
CERENT-GLOBAL-REGISTRY CERENT-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 Unsigned32
Counter32 TEXTUAL-CONVENTION DisplayString
TruthValue TimeStamp MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP cerentProducts
cerentModules CerentNotificationClass

Defined Objects

cerent454MibModule 1.3.6.1.4.1.3607.1.10.20
This module provides the global registrations for all other Cisco OTBU MIB modules.
MODULE-IDENTITY    

cerent454Mib 1.3.6.1.4.1.3607.6.10
The is the node under which all Cisco ONS 15454 specific mib object are located.
OBJECT-IDENTITY    

cerent454Conformance 1.3.6.1.4.1.3607.6.10.10
This node is created compliance. Has objects as required by the RFCs
OBJECT-IDENTITY    

cerent454Groups 1.3.6.1.4.1.3607.6.10.10.10
OBJECT-IDENTITY    

nodeGroup 1.3.6.1.4.1.3607.6.10.10.10.10
The group for node related objects
OBJECT-GROUP    

alarmGroup 1.3.6.1.4.1.3607.6.10.10.10.20
The group for node related objects
OBJECT-GROUP    

eventGroup 1.3.6.1.4.1.3607.6.10.10.10.30
The notifications for Cisco ONS 15454
NOTIFICATION-GROUP    

cerentCommonGroup 1.3.6.1.4.1.3607.6.10.10.10.40
The objects for storing all the current alarms
OBJECT-GROUP    

cerent454Compliance 1.3.6.1.4.1.3607.6.10.10.20
OBJECT-IDENTITY    

cerent454BasicCompliance 1.3.6.1.4.1.3607.6.10.10.20.10
The basic implementation requirements for Cisco ONS 15454 MIB
MODULE-COMPLIANCE    

cerent454Objects 1.3.6.1.4.1.3607.6.10.20
The cerent454 specific objects themselves
OBJECT-IDENTITY    

cerent454GeneralGroup 1.3.6.1.4.1.3607.6.10.20.20
OBJECT-IDENTITY    

cerent454SoftwareVersion 1.3.6.1.4.1.3607.6.10.20.20.10
Indicates the version of software that is used in Cisco ONS 15454. E.g., 2.2.03
OBJECT-TYPE    
  DisplayString  

cerent454AlarmGroup 1.3.6.1.4.1.3607.6.10.20.30
The group that will represent all the alarm info in the Cisco ONS 15454 node
OBJECT-IDENTITY    

cerent454AlarmCount 1.3.6.1.4.1.3607.6.10.20.30.10
Total number of active alarms in Cisco ONS 15454. This equals the total number of rows in cerent454AlarmTable at any time.
OBJECT-TYPE    
  Unsigned32  

cerent454AlarmTable 1.3.6.1.4.1.3607.6.10.20.30.20
This table holds all the current raised alarms. When an alarm is raised, it will appear a new entry in the table. Whenever an alarm is cleared it will be removed from the table and all the entries from below will be moved up by another row.
OBJECT-TYPE    
  SEQUENCE OF  
    Cerent454AlarmEntry

cerent454AlarmEntry 1.3.6.1.4.1.3607.6.10.20.30.20.1
Row definition for cerent454AlarmTable
OBJECT-TYPE    
  Cerent454AlarmEntry  

cerent454AlarmIndex 1.3.6.1.4.1.3607.6.10.20.30.20.1.10
Uniquely identifies each entry in alarm table. So when an alarm in the alarm table clears, the alarms located below the this cleared alarm will have to change their alarm index. Hence there will be holes in the alarm table. May not start with one and there will be some missing numbers.
OBJECT-TYPE    
  Integer32 1..2147483647  

cerent454AlarmObjectType 1.3.6.1.4.1.3607.6.10.20.30.20.1.20
This will indicate what is the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarm
OBJECT-TYPE    
  Cerent454EntityClass  

cerent454AlarmSlotNumber 1.3.6.1.4.1.3607.6.10.20.30.20.1.30
This will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.
OBJECT-TYPE    
  Integer32  

cerent454AlarmPortNumber 1.3.6.1.4.1.3607.6.10.20.30.20.1.40
This will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero.
OBJECT-TYPE    
  Integer32  

cerent454AlarmLineNumber 1.3.6.1.4.1.3607.6.10.20.30.20.1.50
This will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero.
OBJECT-TYPE    
  Integer32  

cerent454AlarmObjectIndex 1.3.6.1.4.1.3607.6.10.20.30.20.1.60
Every alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this index is the index of the interface in the interface table.
OBJECT-TYPE    
  Integer32  

cerent454AlarmType 1.3.6.1.4.1.3607.6.10.20.30.20.1.70
Indicates what the exact nature of the alarm. See the Cerent454AlarmType TC for mapping details
OBJECT-TYPE    
  Cerent454AlarmType  

cerent454AlarmState 1.3.6.1.4.1.3607.6.10.20.30.20.1.80
Specifies alarm severity and service affecting status ( SA/NSA ). Only {minor|major|critical}+{NA|NSA} will be represented here.
OBJECT-TYPE    
  CerentNotificationClass  

cerent454AlarmTimeStamp 1.3.6.1.4.1.3607.6.10.20.30.20.1.90
Indicates when the alarm occurred. The value is number of ticks that has lasped since 1/1/1970
OBJECT-TYPE    
  TimeStamp  

cerent454Events 1.3.6.1.4.1.3607.6.10.30
Place holder for all notifications of Cisco ONS 15454
OBJECT-IDENTITY    

cerent454V2Events 1.3.6.1.4.1.3607.6.10.30.0
The sub-identifier has to be zero, as part of the interoperability agreement between SNMPv1 and SNMPv2 worlds.
OBJECT-IDENTITY    

alarmUnknown 1.3.6.1.4.1.3607.6.10.30.0.1
alarm unknown
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

alarmCutoffIsInManualMode 1.3.6.1.4.1.3607.6.10.30.0.10
alarm cutoff is in manual mode
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

failureDetectedExternalToTheNE 1.3.6.1.4.1.3607.6.10.30.0.20
failure detected External to the NE
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

externalError 1.3.6.1.4.1.3607.6.10.30.0.30
external error
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

excessiveSwitching 1.3.6.1.4.1.3607.6.10.30.0.40
excessive switching
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

terminationFailureSDCC 1.3.6.1.4.1.3607.6.10.30.0.50
SDCC Termination failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

incomingFailureCondition 1.3.6.1.4.1.3607.6.10.30.0.60
incoming failure condition
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

alarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.70
alarm indication signal
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

alarmIndicationSignalLine 1.3.6.1.4.1.3607.6.10.30.0.80
alarm indication signal LINE
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

alarmIndicationSignalPath 1.3.6.1.4.1.3607.6.10.30.0.90
alarm indication signal Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

alarmIndicationSignalVT 1.3.6.1.4.1.3607.6.10.30.0.100
alarm indication signal VT
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelFailureAPS 1.3.6.1.4.1.3607.6.10.30.0.110
channel failure APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelByteFailureAPS 1.3.6.1.4.1.3607.6.10.30.0.120
channel Byte failure APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelProtectionSwitchingChannelMatchFailureAPS 1.3.6.1.4.1.3607.6.10.30.0.130
channel Protection Switching Channel Match failure APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelAutomaticProtectionSwitchModeMismatchAPS 1.3.6.1.4.1.3607.6.10.30.0.140
channel Automatic Protection Switch Mode Mismatch APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelFarEndProtectionLineFailureAPS 1.3.6.1.4.1.3607.6.10.30.0.150
channel far end protection line failure APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelBLSRInconsistentAPSCode 1.3.6.1.4.1.3607.6.10.30.0.160
channel BLSR inconsistent APS code
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelBLSRImproperAPSCodeAPS 1.3.6.1.4.1.3607.6.10.30.0.170
channel BLSR Improper APS code APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelBLSRNodeIdMismatchAPS 1.3.6.1.4.1.3607.6.10.30.0.180
channel BLSR Node Id Mismatch APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelBLSRDefaultKAPS 1.3.6.1.4.1.3607.6.10.30.0.190
channel BLSR Default K APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

channelBLSRConnectionLossAPS 1.3.6.1.4.1.3607.6.10.30.0.200
channel BLSR Connection loss APS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

bipolarViolation 1.3.6.1.4.1.3607.6.10.30.0.210
bipolar Violation
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

carrierLossOnTheLAN 1.3.6.1.4.1.3607.6.10.30.0.220
carrier Loss on the LAN
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

concatenationErrorSTS 1.3.6.1.4.1.3607.6.10.30.0.230
concatenation error STS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

excessCollisionsOnTheLAN 1.3.6.1.4.1.3607.6.10.30.0.240
excess collisions on the LAN
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityCriticalAlarmCausedByDS3FacilityFailure 1.3.6.1.4.1.3607.6.10.30.0.250
facility critical alarm caused by DS3 facility failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndAIS 1.3.6.1.4.1.3607.6.10.30.0.260
far end AIS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndMultipleDS1LOSDetectedOnDS3 1.3.6.1.4.1.3607.6.10.30.0.270
far end Multiple DS1 LOS detected on DS3
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndDS1EqptFailNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.280
far end DS1 eqpt fail non service affecting
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndDS1EqptFailServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.290
far end DS1 Eqpt fail service affecting
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndSingleDS1LOS 1.3.6.1.4.1.3607.6.10.30.0.300
far end Single DS1 LOS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndDS3EqptFailNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.310
far end DS3 Eqpt failure non service affecting
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndDS3EqptFailServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.320
far end DS3 Eqpt failure service affecting
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndCmnEqptFailNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.330
far end common Eqpt failure non service affecting
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndIDLE 1.3.6.1.4.1.3607.6.10.30.0.340
far end IDLE
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndLOS 1.3.6.1.4.1.3607.6.10.30.0.350
far end LOS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndLOF 1.3.6.1.4.1.3607.6.10.30.0.360
far end LOF
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

farEndBlockError 1.3.6.1.4.1.3607.6.10.30.0.370
far End Block Error
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

idleConditionDS3 1.3.6.1.4.1.3607.6.10.30.0.380
idle Condition DS3
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lossOfFrame 1.3.6.1.4.1.3607.6.10.30.0.390
loss of Frame
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lossOfPointer 1.3.6.1.4.1.3607.6.10.30.0.400
loss of Pointer
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lossOfPointerPath 1.3.6.1.4.1.3607.6.10.30.0.410
loss of Pointer Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lossOfPointerVT 1.3.6.1.4.1.3607.6.10.30.0.420
loss of Pointer VT
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lossOfSignal 1.3.6.1.4.1.3607.6.10.30.0.430
loss of Signal
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

outOfFrame 1.3.6.1.4.1.3607.6.10.30.0.440
out of Frame
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

pathSelectorInabilityToSwitchToAValidSignal 1.3.6.1.4.1.3607.6.10.30.0.450
path Selector inability to swtich to a valid signal
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

remoteAlarmIndication 1.3.6.1.4.1.3607.6.10.30.0.460
remote Alarm Indication
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

remoteFailureIndication 1.3.6.1.4.1.3607.6.10.30.0.470
remote Failure Indication
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

remoteFailureIndicationLine 1.3.6.1.4.1.3607.6.10.30.0.480
remote Failure Indication LINE
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

remoteFailureIndicationPath 1.3.6.1.4.1.3607.6.10.30.0.490
remote Failure Indication Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

remoteFailureIndicationVT 1.3.6.1.4.1.3607.6.10.30.0.500
remote Failure Indication VT
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityHasPassedBERThresholdForSignalDegrade 1.3.6.1.4.1.3607.6.10.30.0.510
facility has passed BER Threshold for Signal Degrade
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

severelyErroredFrame 1.3.6.1.4.1.3607.6.10.30.0.520
severely Errored Frame
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityHasPassedBERThresholdForSignalFailure 1.3.6.1.4.1.3607.6.10.30.0.530
facility has passed BER threshold for Signal Failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

signalLabelMismatchFailuresSONET 1.3.6.1.4.1.3607.6.10.30.0.540
signal Label Mismatch Failures SONET
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

signalLabelMismatchFailurePayloadDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.550
signal Label Mismatch Failure Payload Defect Indication
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

signalLabelMismatchFailurePayloadDefectIndicationPath 1.3.6.1.4.1.3607.6.10.30.0.560
signal Label Mismatch Failure Payload Defect Indication Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

signalLabelMismatchFailurePayloadLabelMismatchPath 1.3.6.1.4.1.3607.6.10.30.0.570
signal Label Mismatch Failure Payload Label Mismatch Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

signalLabelMismatchFailurePayloadLabelMismatchVT 1.3.6.1.4.1.3607.6.10.30.0.580
signal Label Mismatch Failure Payload Label Mismatch VT
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

signalLabelMismatchFailureUnequippedPath 1.3.6.1.4.1.3607.6.10.30.0.590
signal Label Mismatch Failure Unequipped Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

signalLabelMismatchFailureUnequippedVT 1.3.6.1.4.1.3607.6.10.30.0.600
signal Label Mismatch Failure Unequipped VT
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  









failedToReceiveSynchronizationStatusMessage 1.3.6.1.4.1.3607.6.10.30.0.690
failed to receive Synchronization Status Message
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationStatusMessagesAreDisabledOnThisInterface 1.3.6.1.4.1.3607.6.10.30.0.700
synchronization Status Messages are disabled on this interface
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

primaryReferenceSourceStratum1Traceable 1.3.6.1.4.1.3607.6.10.30.0.710
primary Reference Source Stratum 1 Traceable
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizedTraceabilityUnknown 1.3.6.1.4.1.3607.6.10.30.0.720
synchronized Traceability Unknown
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

stratum2Traceable 1.3.6.1.4.1.3607.6.10.30.0.730
stratum 2 Traceable
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

transitNodeClockTraceable 1.3.6.1.4.1.3607.6.10.30.0.740
transit Node clock Traceable
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

stratum3ETraceable 1.3.6.1.4.1.3607.6.10.30.0.750
stratum 3E Traceable
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

stratum3Traceable 1.3.6.1.4.1.3607.6.10.30.0.760
stratum 3 Traceable
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

minimumClockTraceableSONET 1.3.6.1.4.1.3607.6.10.30.0.770
SONET Minimum clock Traceable
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

stratum4Traceable 1.3.6.1.4.1.3607.6.10.30.0.780
stratum 4 Traceable
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

doNotUseForSynchronization 1.3.6.1.4.1.3607.6.10.30.0.790
do not Use for Synchronization
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

reservedForNetworkSynchronizationUse 1.3.6.1.4.1.3607.6.10.30.0.800
reserved for Network Synchronization Use
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

outgoingFailureCondition 1.3.6.1.4.1.3607.6.10.30.0.810
outgoing failure condition
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

remoteDefectIndicationLine 1.3.6.1.4.1.3607.6.10.30.0.820
remote Defect Indication LINE
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

remoteDefectIndicationPath 1.3.6.1.4.1.3607.6.10.30.0.830
remote Defect Indication Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

freeRunningSynchronizationMode 1.3.6.1.4.1.3607.6.10.30.0.840
free Running Synchronization mode
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

holdoverSynchronizationMode 1.3.6.1.4.1.3607.6.10.30.0.850
holdover synchronization mode
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

fastStartSynchronizationMode 1.3.6.1.4.1.3607.6.10.30.0.860
fast Start synchronization mode
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

internalHardwareFaultOrFailure 1.3.6.1.4.1.3607.6.10.30.0.870
internal hardware fault or failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

errorInternalToTheNEDetected 1.3.6.1.4.1.3607.6.10.30.0.880
error Internal to the NE Detected
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

internalMessageError 1.3.6.1.4.1.3607.6.10.30.0.890
internal Message Error
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

mismatchOfEquipmentAndAttributes 1.3.6.1.4.1.3607.6.10.30.0.900
mismatch of Equipment and Attributes
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

watchdogTimerTimeout 1.3.6.1.4.1.3607.6.10.30.0.910
watchdog Timer Timeout
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

softwareFaultOrFailure 1.3.6.1.4.1.3607.6.10.30.0.920
software Fault or failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

softwareFaultDataIntegrityFault 1.3.6.1.4.1.3607.6.10.30.0.930
software Fault - Data integrity fault : The newly added provisioning or hardware has caused the database to grow beyond its limit. That is, the newly added object(s) in the system has(have) enough memory to exist onboard but too large to be saved in the database.
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

programFailure 1.3.6.1.4.1.3607.6.10.30.0.940
program failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.950
control Equipment failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentPrimaryNonVolatileBackupMemoryFailure 1.3.6.1.4.1.3607.6.10.30.0.960
control Equipment Primary non volatile Backup Memory failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentSecondaryNonVolatileBackupMemoryFailure 1.3.6.1.4.1.3607.6.10.30.0.970
control Equipment Secondary non volatile Backup Memory failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentControlBusFailure 1.3.6.1.4.1.3607.6.10.30.0.980
control Equipment Control Bus failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentControlBus1Failure 1.3.6.1.4.1.3607.6.10.30.0.990
control Equipment Control Bus 1 failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentControlBus2Failure 1.3.6.1.4.1.3607.6.10.30.0.1000
control Equipment Control Bus 2 failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT1 1.3.6.1.4.1.3607.6.10.30.0.1010
communication failure TCC A to Shelf SLOT 1
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT2 1.3.6.1.4.1.3607.6.10.30.0.1020
communication failure TCC A to Shelf SLOT 2
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT3 1.3.6.1.4.1.3607.6.10.30.0.1030
communication failure TCC A to Shelf SLOT 3
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT4 1.3.6.1.4.1.3607.6.10.30.0.1040
communication failure TCC A to Shelf SLOT 4
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT5 1.3.6.1.4.1.3607.6.10.30.0.1050
communication failure TCC A to Shelf SLOT 5
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT6 1.3.6.1.4.1.3607.6.10.30.0.1060
communication failure TCC A to Shelf SLOT 6
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT7 1.3.6.1.4.1.3607.6.10.30.0.1070
communication failure TCC A to Shelf SLOT 7
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT8 1.3.6.1.4.1.3607.6.10.30.0.1080
communication failure TCC A to Shelf SLOT 8
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT9 1.3.6.1.4.1.3607.6.10.30.0.1090
communication failure TCC A to Shelf SLOT 9
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT10 1.3.6.1.4.1.3607.6.10.30.0.1100
communication failure TCC A to Shelf SLOT 10
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT11 1.3.6.1.4.1.3607.6.10.30.0.1110
communication failure TCC A to Shelf SLOT 11
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT12 1.3.6.1.4.1.3607.6.10.30.0.1120
communication failure TCC A to Shelf SLOT 12
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT13 1.3.6.1.4.1.3607.6.10.30.0.1130
communication failure TCC A to Shelf SLOT 13
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT14 1.3.6.1.4.1.3607.6.10.30.0.1140
communication failure TCC A to Shelf SLOT 14
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT15 1.3.6.1.4.1.3607.6.10.30.0.1150
communication failure TCC A to Shelf SLOT 15
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT16 1.3.6.1.4.1.3607.6.10.30.0.1160
communication failure TCC A to Shelf SLOT 16
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCAToShelfSLOT17 1.3.6.1.4.1.3607.6.10.30.0.1170
communication failure TCC A to Shelf SLOT 17
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCPAToTCCJAprocessor 1.3.6.1.4.1.3607.6.10.30.0.1180
communication failure TCCP A to TCCJ A processor
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT1 1.3.6.1.4.1.3607.6.10.30.0.1190
communication failure TCC B to Shelf SLOT 1
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT2 1.3.6.1.4.1.3607.6.10.30.0.1200
communication failure TCC B to Shelf SLOT 2
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT3 1.3.6.1.4.1.3607.6.10.30.0.1210
communication failure TCC B to Shelf SLOT 3
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT4 1.3.6.1.4.1.3607.6.10.30.0.1220
communication failure TCC B to Shelf SLOT 4
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT5 1.3.6.1.4.1.3607.6.10.30.0.1230
communication failure TCC B to Shelf SLOT 5
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT6 1.3.6.1.4.1.3607.6.10.30.0.1240
communication failure TCC B to Shelf SLOT 6
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT7 1.3.6.1.4.1.3607.6.10.30.0.1250
communication failure TCC B to Shelf SLOT 7
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT8 1.3.6.1.4.1.3607.6.10.30.0.1260
communication failure TCC B to Shelf SLOT 8
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT9 1.3.6.1.4.1.3607.6.10.30.0.1270
communication failure TCC B to Shelf SLOT 9
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT10 1.3.6.1.4.1.3607.6.10.30.0.1280
communication failure TCC B to Shelf SLOT 10
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT11 1.3.6.1.4.1.3607.6.10.30.0.1290
communication failure TCC B to Shelf SLOT 11
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT12 1.3.6.1.4.1.3607.6.10.30.0.1300
communication failure TCC B to Shelf SLOT 12
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT13 1.3.6.1.4.1.3607.6.10.30.0.1310
communication failure TCC B to Shelf SLOT 13
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT14 1.3.6.1.4.1.3607.6.10.30.0.1320
communication failure TCC B to Shelf SLOT 14
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT15 1.3.6.1.4.1.3607.6.10.30.0.1330
communication failure TCC B to Shelf SLOT 15
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT16 1.3.6.1.4.1.3607.6.10.30.0.1340
communication failure TCC B to Shelf SLOT 16
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCBToShelfSLOT17 1.3.6.1.4.1.3607.6.10.30.0.1350
communication failure TCC B to Shelf SLOT 17
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

communicationFailureTCCPBToTCCJAprocessor 1.3.6.1.4.1.3607.6.10.30.0.1360
communication failure TCCP B to TCCJ A processor
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentControlCommunicationsEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1370
control Equipment Control Communications equipment failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentControlProcessorFailure 1.3.6.1.4.1.3607.6.10.30.0.1380
control Equipment Control processor failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

controlEquipmentWorkingMemoryFailure 1.3.6.1.4.1.3607.6.10.30.0.1390
control Equipment Working memory failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1400
interconnection Equipment failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus1Working 1.3.6.1.4.1.3607.6.10.30.0.1410
interconnection Equipment failure Payload Bus 1 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus2Working 1.3.6.1.4.1.3607.6.10.30.0.1420
interconnection Equipment failure Payload Bus 2 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus3Working 1.3.6.1.4.1.3607.6.10.30.0.1430
interconnection Equipment failure Payload Bus 3 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus4Working 1.3.6.1.4.1.3607.6.10.30.0.1440
interconnection Equipment failure Payload Bus 4 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus5Working 1.3.6.1.4.1.3607.6.10.30.0.1450
interconnection Equipment failure Payload Bus 5 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus6Working 1.3.6.1.4.1.3607.6.10.30.0.1460
interconnection Equipment failure Payload Bus 6 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus7Working 1.3.6.1.4.1.3607.6.10.30.0.1470
interconnection Equipment failure Payload Bus 7 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus8Working 1.3.6.1.4.1.3607.6.10.30.0.1480
interconnection Equipment failure Payload Bus 8 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus9Working 1.3.6.1.4.1.3607.6.10.30.0.1490
interconnection Equipment failure Payload Bus 9 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus10Working 1.3.6.1.4.1.3607.6.10.30.0.1500
interconnection Equipment failure Payload Bus 10 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus11Working 1.3.6.1.4.1.3607.6.10.30.0.1510
interconnection Equipment failure Payload Bus 11 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus12Working 1.3.6.1.4.1.3607.6.10.30.0.1520
interconnection Equipment failure Payload Bus 12 Working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus1Protect 1.3.6.1.4.1.3607.6.10.30.0.1530
interconnection Equipment failure Payload Bus 1 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus2Protect 1.3.6.1.4.1.3607.6.10.30.0.1540
interconnection Equipment failure Payload Bus 2 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus3Protect 1.3.6.1.4.1.3607.6.10.30.0.1550
interconnection Equipment failure Payload Bus 3 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus4Protect 1.3.6.1.4.1.3607.6.10.30.0.1560
interconnection Equipment failure Payload Bus 4 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus5Protect 1.3.6.1.4.1.3607.6.10.30.0.1570
interconnection Equipment failure Payload Bus 5 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus6Protect 1.3.6.1.4.1.3607.6.10.30.0.1580
interconnection Equipment failure Payload Bus 6 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus7Protect 1.3.6.1.4.1.3607.6.10.30.0.1590
interconnection Equipment failure Payload Bus 7 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus8Protect 1.3.6.1.4.1.3607.6.10.30.0.1600
interconnection Equipment failure Payload Bus 8 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus9Protect 1.3.6.1.4.1.3607.6.10.30.0.1610
interconnection Equipment failure Payload Bus 9 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus10Protect 1.3.6.1.4.1.3607.6.10.30.0.1620
interconnection Equipment failure Payload Bus 10 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus11Protect 1.3.6.1.4.1.3607.6.10.30.0.1630
interconnection Equipment failure Payload Bus 11 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEquipmentFailurePayloadBus12Protect 1.3.6.1.4.1.3607.6.10.30.0.1640
interconnection Equipment failure Payload Bus 12 Protect
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

interconnectionEqptTimeSlotInterchangeEqptFailure 1.3.6.1.4.1.3607.6.10.30.0.1650
interconnection Eqpt Time slot interchange eqpt failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

criticalAlarmCausedByEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1660
critical alarm caused by equipment failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

equipmentFailureHighTemperature 1.3.6.1.4.1.3607.6.10.30.0.1670
equipment failure High temperature
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

equipmentFailureInvalidMACAddress 1.3.6.1.4.1.3607.6.10.30.0.1680
equipment failure Invalid MAC Address
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

equipmentFailureBoardFailure 1.3.6.1.4.1.3607.6.10.30.0.1690
equipment failure Board Failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

equipmentFailureDiagnosticsFailure 1.3.6.1.4.1.3607.6.10.30.0.1700
equipment failure Diagnostics Failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

equipmentFailureMediumAccessControl 1.3.6.1.4.1.3607.6.10.30.0.1710
equipment failure Medium Access Control
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityTerminationEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1720
facility Termination equipment failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityTerminationEquipmentAutomaticLaserShutdown 1.3.6.1.4.1.3607.6.10.30.0.1730
facility Termination Equipment Automatic Laser Shutdown
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

failureToReleaseFromProtection 1.3.6.1.4.1.3607.6.10.30.0.1740
failure To Release from protection
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityTerminationEquipmentReceiverFailure 1.3.6.1.4.1.3607.6.10.30.0.1750
facility Termination equipment Receiver failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityTerminationEquipmentTransmitFailure 1.3.6.1.4.1.3607.6.10.30.0.1760
facility Termination equipment Transmit failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityTerminationEquipmentReceiverMissing 1.3.6.1.4.1.3607.6.10.30.0.1770
facility Termination equipment Receiver missing
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

facilityTerminationEquipmentTransmitterMissing 1.3.6.1.4.1.3607.6.10.30.0.1780
facility Termination equipment Transmitter missing
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

failureToSwitchToProtection 1.3.6.1.4.1.3607.6.10.30.0.1790
failure To Switch to protection
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

failureToSwitchToProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.1800
failure To Switch to protection Ring
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

failureToSwitchToProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.1810
failure To Switch to protection Span
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

failureToSwitchToProtectionPath 1.3.6.1.4.1.3607.6.10.30.0.1820
failure to Switch to protection Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

failureOfCoolingFanTray 1.3.6.1.4.1.3607.6.10.30.0.1830
failure of cooling fan tray
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

equipmentUnitPlugIn 1.3.6.1.4.1.3607.6.10.30.0.1840
equipment unit plug in
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

powerFailureDetectedInternalToNE 1.3.6.1.4.1.3607.6.10.30.0.1850
power failure detected internal to NE
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

powerFailureFuseAlarm 1.3.6.1.4.1.3607.6.10.30.0.1860
power failure Fuse Alarm
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationUnitFailure 1.3.6.1.4.1.3607.6.10.30.0.1870
synchronization unit failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchingEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1880
synchronization switching Equipment failure
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

equipmentUnitUnplug 1.3.6.1.4.1.3607.6.10.30.0.1890
equipment unit un plug
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopback 1.3.6.1.4.1.3607.6.10.30.0.1900
loop back
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackDueToFEACCommandDS1 1.3.6.1.4.1.3607.6.10.30.0.1910
loopback due to FEAC command DS1
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackCommandSentToFarEndDS1 1.3.6.1.4.1.3607.6.10.30.0.1920
loopback Command sent to Far End DS1
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackDueToFEACCommandDS3 1.3.6.1.4.1.3607.6.10.30.0.1930
loopback due to FEAC command DS3
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackCommandSentToFarEndDS3 1.3.6.1.4.1.3607.6.10.30.0.1940
loopback Command sent to Far End DS3
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackDueToFarEndCommandDS2 1.3.6.1.4.1.3607.6.10.30.0.1950
loopback due to Far End Command DS2
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackCommandSentToFarEndDS2 1.3.6.1.4.1.3607.6.10.30.0.1960
loopback Command sent to Far End DS2
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackFacility 1.3.6.1.4.1.3607.6.10.30.0.1970
loop back facility
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackNetwork 1.3.6.1.4.1.3607.6.10.30.0.1980
loop back Network
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

loopbackTerminal 1.3.6.1.4.1.3607.6.10.30.0.1990
loop back Terminal
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manuallyCausedAbnormalCondition 1.3.6.1.4.1.3607.6.10.30.0.2000
manually caused abnormal condition
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

newRootDiscoveredInBridgedNetwork 1.3.6.1.4.1.3607.6.10.30.0.2010
new Root discovered in bridged network
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

topologyChangeDiscoveredInBridgedNetwork 1.3.6.1.4.1.3607.6.10.30.0.2020
topology change discovered in bridged network
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

normalCondition 1.3.6.1.4.1.3607.6.10.30.0.2030
normal condition
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

embeddedOperationsChannelFailureLinkDown 1.3.6.1.4.1.3607.6.10.30.0.2040
embedded Operations Channel failure link down
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

peerStateMismatch 1.3.6.1.4.1.3607.6.10.30.0.2050
peer state mismatch
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

proceduralError 1.3.6.1.4.1.3607.6.10.30.0.2060
procedural Error
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

proceduralErrorImproperRemoval 1.3.6.1.4.1.3607.6.10.30.0.2070
procedural Error Improper Removal
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

proceduralErrorDuplicateNodeID 1.3.6.1.4.1.3607.6.10.30.0.2080
procedural Error Duplicate Node ID
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

proceduralErrorBLSROutOfSync 1.3.6.1.4.1.3607.6.10.30.0.2090
procedural Error BLSR out of sync
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

resynchronizedBLSRTables 1.3.6.1.4.1.3607.6.10.30.0.2100
BLSR tables resynchronized
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

protectionUnitNotAvailable 1.3.6.1.4.1.3607.6.10.30.0.2110
protection unit not available
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

performanceMonitorThresholdCrossingAlert 1.3.6.1.4.1.3607.6.10.30.0.2120
performance Monitor Threshold Crossing Alert
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

occurrenceOfAProtectionSwitchingEvent 1.3.6.1.4.1.3607.6.10.30.0.2130
occurrence of a protection switching event
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

recoveryOrServiceProtectionActionHasBeenInitiated 1.3.6.1.4.1.3607.6.10.30.0.2140
recovery or service protection action has been initiated
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

automaticSystemReset 1.3.6.1.4.1.3607.6.10.30.0.2150
automatic system Reset
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

automacticUPSRSwitchCausedByAIS 1.3.6.1.4.1.3607.6.10.30.0.2160
automactic UPSR switch caused by AIS
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

automacticUPSRSwitchCausedByLOP 1.3.6.1.4.1.3607.6.10.30.0.2170
automactic UPSR switch caused by Lop
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

automacticUPSRSwitchCausedByUneq 1.3.6.1.4.1.3607.6.10.30.0.2180
automactic UPSR switch caused by Uneq
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

automacticUPSRSwitchCausedByPDI 1.3.6.1.4.1.3607.6.10.30.0.2190
automactic UPSR switch caused by PDI
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

automacticUPSRSwitchCausedBySfber 1.3.6.1.4.1.3607.6.10.30.0.2200
automactic UPSR switch caused by Sfber
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

automacticUPSRSwitchCausedBySdber 1.3.6.1.4.1.3607.6.10.30.0.2210
automactic UPSR switch caused by Sdber
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

coldRestart 1.3.6.1.4.1.3607.6.10.30.0.2220
cold Restart
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptForcedSwitchedToWorking 1.3.6.1.4.1.3607.6.10.30.0.2230
working facility or eqpt forced switched to working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptForcedSwitchedToWorkingRing 1.3.6.1.4.1.3607.6.10.30.0.2240
working facility or eqpt forced switched to working Ring
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptForcedSwitchedToWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.2250
working facility or eqpt forced switched to working Span
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptForcedSwitchedProtectionUnit 1.3.6.1.4.1.3607.6.10.30.0.2260
working facility or eqpt forced switched protection unit
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptForcedSwitchedProtectionUnitRing 1.3.6.1.4.1.3607.6.10.30.0.2270
working facility or eqpt forced switched protection unit Ring
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptForcedSwitchedProtectionUnitSpan 1.3.6.1.4.1.3607.6.10.30.0.2280
working facility or eqpt forced switched protection unit Span
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptForcedSwitchedProtectionUnitPath 1.3.6.1.4.1.3607.6.10.30.0.2290
working facility or eqpt forced switched protection unit Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

initializationInitiated 1.3.6.1.4.1.3607.6.10.30.0.2300
initialization initiated
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutOfProtection 1.3.6.1.4.1.3607.6.10.30.0.2310
lockout of Protection
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutOfProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2320
lockout of Protection Ring
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutOfProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.2330
lockout of Protection Span
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutOfProtectionPath 1.3.6.1.4.1.3607.6.10.30.0.2340
lockout of Protection Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutOfWorking 1.3.6.1.4.1.3607.6.10.30.0.2350
lockout of working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutOfWorkingRing 1.3.6.1.4.1.3607.6.10.30.0.2360
lockout of working Ring
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutOfWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.2370
lockout of working Span
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSystemReset 1.3.6.1.4.1.3607.6.10.30.0.2380
manual system Reset
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSynchronizationSwitchToInternalClock 1.3.6.1.4.1.3607.6.10.30.0.2390
manual synchronization switch to internal clock
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSynchronizationSwitchToPrimaryRefernce 1.3.6.1.4.1.3607.6.10.30.0.2400
manual synchronization Switch To Primary refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSynchronizationSwitchToSecondRefernce 1.3.6.1.4.1.3607.6.10.30.0.2410
manual synchronization Switch To Second refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSynchronizationSwitchToThirdRefernce 1.3.6.1.4.1.3607.6.10.30.0.2420
manual synchronization Switch To Third refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSynchronizationSwitchToFourthRefernce 1.3.6.1.4.1.3607.6.10.30.0.2430
manual synchronization Switch To Fourth refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSynchronizationSwitchToFifthRefernce 1.3.6.1.4.1.3607.6.10.30.0.2440
manual synchronization Switch To Fifth refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSynchronizationSwitchToSixthRefernce 1.3.6.1.4.1.3607.6.10.30.0.2450
manual synchronization Switch To Sixth refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSwitchOfWorkingFacilityOrEqptToProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2460
manualSwitch of working facility or eqpt to protection Ring
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSwitchOfWorkingFacilityOrEqptToProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.2470
manualSwitch of working facility or eqpt to protection Span
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSwitchOfWorkingFacilityOrEqptToProtection 1.3.6.1.4.1.3607.6.10.30.0.2480
manualSwitch of working facility or eqpt to protection
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSwitchOfWorkingFacilityOrEqptToProtectionUnit 1.3.6.1.4.1.3607.6.10.30.0.2490
manualSwitch of Working facility or eqpt to Protection unit
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptManualSwitchToProtectionUnitRing 1.3.6.1.4.1.3607.6.10.30.0.2500
working facility or eqpt manualSwitch to Protection unit Ring
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEqptManualSwitchToProtectionUnitSpan 1.3.6.1.4.1.3607.6.10.30.0.2510
working facility or eqpt manualSwitch to Protection unit Span
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSwitchOfWorkingFacilityOrEqptToProtectionPath 1.3.6.1.4.1.3607.6.10.30.0.2520
manualSwitch of working facility or eqpt to Protection Path
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

powerFailureRestart 1.3.6.1.4.1.3607.6.10.30.0.2530
power failure Restart
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

ringIsSquelchingTraffic 1.3.6.1.4.1.3607.6.10.30.0.2540
ring is squelching traffic
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

softwareDownloadInProgress 1.3.6.1.4.1.3607.6.10.30.0.2550
software download in progress
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchToInternalClock 1.3.6.1.4.1.3607.6.10.30.0.2560
synchronization Switch To Internal clock
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchToPrimaryRefernce 1.3.6.1.4.1.3607.6.10.30.0.2570
synchronization Switch To Primary refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchToSecondRefernce 1.3.6.1.4.1.3607.6.10.30.0.2580
synchronization Switch To Second refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchToThirdRefernce 1.3.6.1.4.1.3607.6.10.30.0.2590
synchronization Switch To Third refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchToFourthRefernce 1.3.6.1.4.1.3607.6.10.30.0.2600
synchronization Switch To Fourth refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchToFifthRefernce 1.3.6.1.4.1.3607.6.10.30.0.2610
synchronization Switch To Fifth refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

synchronizationSwitchToSixthRefernce 1.3.6.1.4.1.3607.6.10.30.0.2620
synchronization Switch To Sixth refernce
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

systemReboot 1.3.6.1.4.1.3607.6.10.30.0.2630
system reboot
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEquipmentSwitchedBackToWorking 1.3.6.1.4.1.3607.6.10.30.0.2640
working facility or equipment switched back to working
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

workingFacilityOrEquipmentSwitchedToProtectionUnit 1.3.6.1.4.1.3607.6.10.30.0.2650
working facility or equipment switched to protection unit
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

warmRestart 1.3.6.1.4.1.3607.6.10.30.0.2660
warm Restart
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

isInWaitToRestoreStateSONETLine 1.3.6.1.4.1.3607.6.10.30.0.2670
SONET line is in Wait To Restore state
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

manualSwitchRequestOnFacilityOrEquipment 1.3.6.1.4.1.3607.6.10.30.0.2680
manual switch request on facility or equipment
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

forceSwitchRequestOnFacilityOrEquipment 1.3.6.1.4.1.3607.6.10.30.0.2690
force switch request on facility or equipment
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

lockoutSwitchRequestOnFacilityOrEquipment 1.3.6.1.4.1.3607.6.10.30.0.2700
lockout switch request on facility or equipment
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

rmonHistoriesAndAlarmsReset 1.3.6.1.4.1.3607.6.10.30.0.2710
RMON histories and alarms have been reset due to chipset reboot
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

freeMemoryOnCardVeryLow 1.3.6.1.4.1.3607.6.10.30.0.2830
Free memory on the card is very low
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

freeMemoryOnCardAlmostGone 1.3.6.1.4.1.3607.6.10.30.0.2840
Free memory on the card is almost gone
NOTIFICATION-TYPE    
  cerentNodeTime  
  cerent454AlarmState  
  cerent454AlarmObjectType  
  cerent454AlarmObjectIndex  
  cerent454AlarmSlotNumber  
  cerent454AlarmPortNumber  
  cerent454AlarmLineNumber  

cerentCommonObjects 1.3.6.1.4.1.3607.6.10.100
The objects here are expected to be used by all Cisco OTBU Products. These will be mixed with specific objects of the product-specific branch.
OBJECT-IDENTITY    

cerentCommonObjectsGroup 1.3.6.1.4.1.3607.6.10.100.10
The group to combine all the Cisco OTBU common objects
OBJECT-IDENTITY    

cerentEnableNotification 1.3.6.1.4.1.3607.6.10.100.10.10
This variable indicates whether the system produces notifications. A value=FALSE will prevent notifications from being sent by this system.
OBJECT-TYPE    
  TruthValue  

cerentNodeTime 1.3.6.1.4.1.3607.6.10.100.10.20
Indicates current local time as reflected by the Cisco OTBU equipment. The format this scalar is YYYYMMDDhhmmss{S/D}. E.g., 20011103133453D means 1:34:53 PM PDT on 03/Nov/2001 19990614095436S means 9:54:36 AM PST on 14/Jun/1999. If the last octet is S then the time is standard time. Otherwise it is D to indicate it is daylight saving time, if applicable
OBJECT-TYPE    
  DisplayString  

cerentNotificationsSent 1.3.6.1.4.1.3607.6.10.100.10.30
A count of v1+v2 notifications sent out by the agent. Resets to zero after cold/warm start.
OBJECT-TYPE    
  Counter32  

cerentLastChangeTime 1.3.6.1.4.1.3607.6.10.100.10.40
The value of sysUpTime at the time a conceptual row is created or deleted in cerent454AlarmTable
OBJECT-TYPE    
  TimeStamp  

cerentCommonEvents 1.3.6.1.4.1.3607.6.10.200
This branch is similar to cerentCommonObjects, except that this will have only events
OBJECT-IDENTITY    

Defined Objects

Cerent454AlarmType  
This TC is used by the NMS to map the alarm type received by the trap and and display the string shown in LHS.
TEXTUAL-CONVENTION    
  INTEGER alarmUnknown(1), alarmCutoffIsInManualMode(10), failureDetectedexternalToTheNE(20), externalError(30), excessiveSwitching(40), terminationFailureSDCC(50), incomingFailureCondition(60), alarmIndicationSignal(70), alarmIndicationSignalLine(80), alarmIndicationSignalPath(90), alarmIndicationSignalVT(100), channelFailureAPS(110), channelByteFailureAPS(120), channelProtectionSwitchingChannelMatchFailureAPS(130), channelAutomaticProtectionSwitchModeMismatchAPS(140), channelFarEndProtectionLineFailureAPS(150), channelBLSRInconsistentAPSCode(160), channelBLSRImproperAPSCodeAPS(170), channelBLSRNodeIdMismatchAPS(180), channelBLSRDefaultKAPS(190), channelBLSRConnectionLossAPS(200), bipolarViolation(210), carrierLossOnTheLAN(220), concatenationErrorSTS(230), excessCollisionsOnTheLAN(240), facilityCriticalAlarmCausedByDS3FacilityFailure(250), farEndAIS(260), farEndMultipleDS1LOSDetectedOnDS3(270), farEndDS1EqptFailNonServiceAffecting(280), farEndDS1EqptFailServiceAffecting(290), farEndSingleDS1LOS(300), farEndDS3EqptFailNonServiceAffecting(310), farEndDS3EqptFailServiceAffecting(320), farEndCmnEqptFailNonServiceAffecting(330), farEndIDLE(340), farEndLOS(350), farEndLOF(360), farEndBlockError(370), idleConditionDS3(380), lossOfFrame(390), lossOfPointer(400), lossOfPointerPath(410), lossOfPointerVT(420), lossOfSignal(430), outOfFrame(440), pathSelectorInabilityToSwitchToAValidSignal(450), remoteAlarmIndication(460), remoteFailureIndication(470), remoteFailureIndicationLine(480), remoteFailureIndicationPath(490), remoteFailureIndicationVT(500), facilityHasPassedBERThresholdForSignalDegrade(510), severelyErroredFrame(520), facilityHasPassedBERThresholdForSignalFailure(530), signalLabelMismatchFailuresSONET(540), signalLabelMismatchFailurePayloadDefectIndication(550), signalLabelMismatchFailurePayloadDefectIndicationPath(560), signalLabelMismatchFailurePayloadLabelMismatchPath(570), signalLabelMismatchFailurePayloadLabelMismatchVT(580), signalLabelMismatchFailureUnequippedPath(590), signalLabelMismatchFailureUnequippedVT(600), lossOfTimingOnSynchronizationLink(610), lossOfTimingOnAllSpecifiedSynchronizationLinks(620), lossOfTimingOnPrimarySynchronizationLink(630), lossOfTimingOnSecondarySynchronizationLink(640), lossOfTimingOnThirdSynchronizationLink(650), lossOfTimingOnFourthSynchronizationLink(660), lossOfTimingOnFifthSynchronizationLink(670), lossOfTimingOnSixthSynchronizationLink(680), failedToReceiveSynchronizationStatusMessage(690), synchronizationStatusMessagesAreDisabledOnThisInterface(700), primaryReferenceSourceStratum1Traceable(710), synchronizedTraceabilityUnknown(720), stratum2Traceable(730), transiTNodeClockTraceable(740), stratum3ETraceable(750), stratum3Traceable(760), minimumClockTraceableSONET(770), stratum4Traceable(780), doNotUseForSynchronization(790), reservedForNetworkSynchronizationUse(800), outgoingFailureCondition(810), remoteDefectIndicationLine(820), remoteDefectIndicationPath(830), freeRunningSynchronizationMode(840), holdoverSynchronizationMode(850), fastStartSynchronizationMode(860), internalHardwareFaultOrFailure(870), errorInternalToTheNEDetected(880), internalMessageError(890), mismatchOfEquipmentAndAttributes(900), watchdogTimerTimeout(910), softwareFaultOrFailure(920), softwareFaultDataIntegrityFault(930), programFailure(940), controlEquipmentFailure(950), controlEquipmentPrimaryNonVolatileBackupMemoryFailure(960), controlEquipmentSecondaryNonVolatileBackupMemoryFailure(970), controlEquipmentControlBusFailure(980), controlEquipmentControlBus1Failure(990), controlEquipmentControlBus2Failure(1000), communicationFailureTCCAToShelfSLOT1(1010), communicationFailureTCCAToShelfSLOT2(1020), communicationFailureTCCAToShelfSLOT3(1030), communicationFailureTCCAToShelfSLOT4(1040), communicationFailureTCCAToShelfSLOT5(1050), communicationFailureTCCAToShelfSLOT6(1060), communicationFailureTCCAToShelfSLOT7(1070), communicationFailureTCCAToShelfSLOT8(1080), communicationFailureTCCAToShelfSLOT9(1090), communicationFailureTCCAToShelfSLOT10(1100), communicationFailureTCCAToShelfSLOT11(1110), communicationFailureTCCAToShelfSLOT12(1120), communicationFailureTCCAToShelfSLOT13(1130), communicationFailureTCCAToShelfSLOT14(1140), communicationFailureTCCAToShelfSLOT15(1150), communicationFailureTCCAToShelfSLOT16(1160), communicationFailureTCCAToShelfSLOT17(1170), communicationFailureTCCPAToTCCJAprocessor(1180), communicationFailureTCCBToShelfSLOT1(1190), communicationFailureTCCBToShelfSLOT2(1200), communicationFailureTCCBToShelfSLOT3(1210), communicationFailureTCCBToShelfSLOT4(1220), communicationFailureTCCBToShelfSLOT5(1230), communicationFailureTCCBToShelfSLOT6(1240), communicationFailureTCCBToShelfSLOT7(1250), communicationFailureTCCBToShelfSLOT8(1260), communicationFailureTCCBToShelfSLOT9(1270), communicationFailureTCCBToShelfSLOT10(1280), communicationFailureTCCBToShelfSLOT11(1290), communicationFailureTCCBToShelfSLOT12(1300), communicationFailureTCCBToShelfSLOT13(1310), communicationFailureTCCBToShelfSLOT14(1320), communicationFailureTCCBToShelfSLOT15(1330), communicationFailureTCCBToShelfSLOT16(1340), communicationFailureTCCBToShelfSLOT17(1350), communicationFailureTCCPBToTCCJAprocessor(1360), controlEquipmentControlCommunicationsEquipmentFailure(1370), controlEquipmentControlProcessorFailure(1380), controlEquipmentWorkingMemoryFailure(1390), interconnectionEquipmentFailure(1400), interconnectionEquipmentFailurePayloadBus1Working(1410), interconnectionEquipmentFailurePayloadBus2Working(1420), interconnectionEquipmentFailurePayloadBus3Working(1430), interconnectionEquipmentFailurePayloadBus4Working(1440), interconnectionEquipmentFailurePayloadBus5Working(1450), interconnectionEquipmentFailurePayloadBus6Working(1460), interconnectionEquipmentFailurePayloadBus7Working(1470), interconnectionEquipmentFailurePayloadBus8Working(1480), interconnectionEquipmentFailurePayloadBus9Working(1490), interconnectionEquipmentFailurePayloadBus10Working(1500), interconnectionEquipmentFailurePayloadBus11Working(1510), interconnectionEquipmentFailurePayloadBus12Working(1520), interconnectionEquipmentFailurePayloadBus1Protect(1530), interconnectionEquipmentFailurePayloadBus2Protect(1540), interconnectionEquipmentFailurePayloadBus3Protect(1550), interconnectionEquipmentFailurePayloadBus4Protect(1560), interconnectionEquipmentFailurePayloadBus5Protect(1570), interconnectionEquipmentFailurePayloadBus6Protect(1580), interconnectionEquipmentFailurePayloadBus7Protect(1590), interconnectionEquipmentFailurePayloadBus8Protect(1600), interconnectionEquipmentFailurePayloadBus9Protect(1610), interconnectionEquipmentFailurePayloadBus10Protect(1620), interconnectionEquipmentFailurePayloadBus11Protect(1630), interconnectionEquipmentFailurePayloadBus12Protect(1640), interconnectionEqptTimeSlotInterchangeEqptFailure(1650), criticalAlarmCausedByEquipmentFailure(1660), equipmentFailureHighTemperature(1670), equipmentFailureInvalidMACAddress(1680), equipmentFailureBoardFailure(1690), equipmentFailureDiagnosticsFailure(1700), equipmentFailureMediumAccessControl(1710), facilityTerminationEquipmentFailure(1720), facilityTerminationEquipmentAutomaticLaserShutdown(1730), failureToReleaseFromProtection(1740), facilityTerminationEquipmentReceiverFailure(1750), facilityTerminationEquipmentTransmitFailure(1760), facilityTerminationEquipmentReceiverMissing(1770), facilityTerminationEquipmentTransmitterMissing(1780), failureToSwitchToProtection(1790), failureToSwitchToProtectionRing(1800), failureToSwitchToProtectionSpan(1810), failureToSwitchToProtectionPath(1820), failureOfCoolingFanTray(1830), equipmentUnitPlugIn(1840), powerFailureDetectedInternalToNE(1850), powerFailureFuseAlarm(1860), synchronizationUnitFailure(1870), synchronizationSwitchingEquipmentFailure(1880), equipmentUnitUnplug(1890), loopback(1900), loopbackDueToFEACCommandDS1(1910), loopbackCommandSentToFarEndDS1(1920), loopbackDueToFEACCommandDS3(1930), loopbackCommandSentToFarEndDS3(1940), loopbackDueToFarEndCommandDS2(1950), loopbackCommandSentToFarEndDS2(1960), loopbackFacility(1970), loopbackNetwork(1980), loopbackTerminal(1990), manuallyCausedAbnormalCondition(2000), newRootDiscoveredInBridgedNetwork(2010), topologyChangeDiscoveredInBridgedNetwork(2020), normalCondition(2030), embeddedOperationsChannelFailureLinkDown(2040), peerStateMismatch(2050), proceduralError(2060), proceduralErrorImproperRemoval(2070), proceduralErrorDuplicateNodeID(2080), proceduralErrorBLSROutOfSync(2090), resynchronizedBLSRTables(2100), protectionUnitNotAvailable(2110), performanceMonitorThresholdCrossingAlert(2120), occurrenceOfAProtectionSwitchingEvent(2130), recoveryOrServiceProtectionActionHasBeenInitiated(2140), automaticSystemReset(2150), automacticUPSRSwitchCausedByAIS(2160), automacticUPSRSwitchCausedByLOP(2170), automacticUPSRSwitchCausedByUneq(2180), automacticUPSRSwitchCausedByPDI(2190), automacticUPSRSwitchCausedBySfber(2200), automacticUPSRSwitchCausedBySdber(2210), coldRestart(2220), workingFacilityOrEqptForcedSwitchedToWorking(2230), workingFacilityOrEqptForcedSwitchedToWorkingRing(2240), workingFacilityOrEqptForcedSwitchedToWorkingSpan(2250), workingFacilityOrEqptForcedSwitchedProtectionUnit(2260), workingFacilityOrEqptForcedSwitchedProtectionUnitRing(2270), workingFacilityOrEqptForcedSwitchedProtectionUnitSpan(2280), workingFacilityOrEqptForcedSwitchedProtectionUnitPath(2290), initializationInitiated(2300), lockoutOfProtection(2310), lockoutOfProtectionRing(2320), lockoutOfProtectionSpan(2330), lockoutOfProtectionPath(2340), lockoutOfWorking(2350), lockoutOfWorkingRing(2360), lockoutOfWorkingSpan(2370), manualSystemReset(2380), manualSynchronizationSwitchToInternalClock(2390), manualSynchronizationSwitchToPrimaryRefernce(2400), manualSynchronizationSwitchToSecondRefernce(2410), manualSynchronizationSwitchToThirdRefernce(2420), manualSynchronizationSwitchToFourthRefernce(2430), manualSynchronizationSwitchToFifthRefernce(2440), manualSynchronizationSwitchToSixthRefernce(2450), manualSwitchOfWorkingFacilityOrEqptToProtectionRing(2460), manualSwitchOfWorkingFacilityOrEqptToProtectionSpan(2470), manualSwitchOfWorkingFacilityOrEqptToProtection(2480), manualSwitchOfWorkingFacilityOrEqptToProtectionUnit(2490), workingFacilityOrEqptManualSwitchToProtectionUnitRing(2500), workingFacilityOrEqptManualSwitchToProtectionUnitSpan(2510), manualSwitchOfWorkingFacilityOrEqptToProtectionPath(2520), powerFailureRestart(2530), ringIsSquelchingTraffic(2540), softwareDownloadInProgress(2550), synchronizationSwitchToInternalClock(2560), synchronizationSwitchToPrimaryRefernce(2570), synchronizationSwitchToSecondRefernce(2580), synchronizationSwitchToThirdRefernce(2590), synchronizationSwitchToFourthRefernce(2600), synchronizationSwitchToFifthRefernce(2610), synchronizationSwitchToSixthRefernce(2620), systemReboot(2630), workingFacilityOrEquipmentSwitchedBackToWorking(2640), workingFacilityOrEquipmentSwitchedToProtectionUnit(2650), warmRestart(2660), lineIsInWaitToRestoreStateSONET(2670), manualSwitchRequestOnFacilityOrEquipment(2680), forceSwitchRequestOnFacilityOrEquipment(2690), lockoutSwitchRequestOnFacilityOrEquipment(2700), rmonHistoriesAndAlarmsReset(2710), rmonThresholdCrossingAlarm(2720), freeMemoryOnCardVeryLow(2830), freeMemoryOnCardAlmostGone(2840)  

Cerent454EntityClass  
This is the TC used to find out to which cerent454EntityClass an alarm belongs to. The first octet of the alarmIndex value is mapped to the following enum. Look at cerent454AlarmIndex for more details.
TEXTUAL-CONVENTION    
  INTEGER unknownEntity(1), ne(10), ccNe(20), backplane(30), ccBackplane(40), eqpt(50), ccEqpt(60), ocn(70), ccOcn(80), thOcn(90), sdcc(100), ds3(110), ccDs3(120), thDs3(130), stsMon(140), ccStsMon(150), stsTerm(160), ccStsTerm(170), thStsTerm(180), psSts(190), ccPsSts(200), xcSts(210), bits(220), ccBits(230), neSynchref(240), ccNeSynchref(250), extSynchref(260), ccExtSynchref(270), envalrm(280), envctrl(290), javaSpe(300), ringMap(310), squelchTable(320), payloadTable(330), userTable(340), routingTable(350), stsRing(360), ifGrp(370), craft(380), ds1(390), ccDs1(400), thDs1(410), vtTerm(420), ccVtTerm(430), thVtTerm(440), spareSdcc(450), ccSdcc(460), thSdcc(470), ds2(480), ccDs2(490), thDs2(500), ec112(510), ps(520), psVt(530), e100t(540), e1000f(550), etherBridge(560), entNb(570), entDs1(1010), entDs3(1020), ringPort(1180), ringPath(1190), entOc3(1200), entOc12(1210), entOc48(1220), entOc192(1230), entSts1(1240), entSts3c(1250), entSts12c(1260), entSts48c(1270), entSyncn(1280)  

Cerent454AlarmEntry  
SEQUENCE    
  Integer32 as cerent454AlarmIndex  
  Cerent454EntityClass as cerent454AlarmObjectType  
  Integer32 as cerent454AlarmSlotNumber  
  Integer32 as cerent454AlarmPortNumber  
  Integer32 as cerent454AlarmLineNumber  
  Integer32 as cerent454AlarmObjectIndex  
  Cerent454AlarmType as cerent454AlarmType  
  CerentNotificationClass as cerent454AlarmState  
  TimeStamp as cerent454AlarmTimeStamp