
| SNMPv2-SMI | SNMPv2-TC | SNMPv2-CONF |
| CERENT-GLOBAL-REGISTRY | CERENT-TC |
| cerent454MibModule | 1.3.6.1.4.1.3607.1.10.20 | ||
| This module provides the global registrations for all other Cisco OTBU MIB modules. | |||
| MODULE-IDENTITY | |||
| cerent454Mib | 1.3.6.1.4.1.3607.6.10 | ||
| The is the node under which all Cisco ONS 15454 specific mib object are located. | |||
| OBJECT-IDENTITY | |||
| cerent454Conformance | 1.3.6.1.4.1.3607.6.10.10 | ||
| This node is created compliance. Has objects as required by the RFCs | |||
| OBJECT-IDENTITY | |||
| cerent454Groups | 1.3.6.1.4.1.3607.6.10.10.10 | ||
| OBJECT-IDENTITY | |||
| nodeGroup | 1.3.6.1.4.1.3607.6.10.10.10.10 | ||
| The group for node related objects | |||
| OBJECT-GROUP | |||
| alarmGroup | 1.3.6.1.4.1.3607.6.10.10.10.20 | ||
| The group for node related objects | |||
| OBJECT-GROUP | |||
| eventGroup | 1.3.6.1.4.1.3607.6.10.10.10.30 | ||
| The notifications for Cisco ONS 15454 | |||
| NOTIFICATION-GROUP | |||
| cerentCommonGroup | 1.3.6.1.4.1.3607.6.10.10.10.40 | ||
| The objects for storing all the current alarms | |||
| OBJECT-GROUP | |||
| cerent454Compliance | 1.3.6.1.4.1.3607.6.10.10.20 | ||
| OBJECT-IDENTITY | |||
| cerent454BasicCompliance | 1.3.6.1.4.1.3607.6.10.10.20.10 | ||
| The basic implementation requirements for Cisco ONS 15454 MIB | |||
| MODULE-COMPLIANCE | |||
| cerent454Objects | 1.3.6.1.4.1.3607.6.10.20 | ||
| The cerent454 specific objects themselves | |||
| OBJECT-IDENTITY | |||
| cerent454GeneralGroup | 1.3.6.1.4.1.3607.6.10.20.20 | ||
| OBJECT-IDENTITY | |||
| cerent454SoftwareVersion | 1.3.6.1.4.1.3607.6.10.20.20.10 | ||
| Indicates the version of software that is used in Cisco ONS 15454. E.g., 2.2.03 | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cerent454AlarmGroup | 1.3.6.1.4.1.3607.6.10.20.30 | ||
| The group that will represent all the alarm info in the Cisco ONS 15454 node | |||
| OBJECT-IDENTITY | |||
| cerent454AlarmCount | 1.3.6.1.4.1.3607.6.10.20.30.10 | ||
| Total number of active alarms in Cisco ONS 15454. This equals the total number of rows in cerent454AlarmTable at any time. | |||
| OBJECT-TYPE | |||
| Unsigned32 | |||
| cerent454AlarmTable | 1.3.6.1.4.1.3607.6.10.20.30.20 | ||
| This table holds all the current raised alarms. When an alarm is raised, it will appear a new entry in the table. Whenever an alarm is cleared it will be removed from the table and all the entries from below will be moved up by another row. | |||
| OBJECT-TYPE | |||
| SEQUENCE OF | |||
| Cerent454AlarmEntry | |||
| cerent454AlarmEntry | 1.3.6.1.4.1.3607.6.10.20.30.20.1 | ||
| Row definition for cerent454AlarmTable | |||
| OBJECT-TYPE | |||
| Cerent454AlarmEntry | |||
| cerent454AlarmIndex | 1.3.6.1.4.1.3607.6.10.20.30.20.1.10 | ||
| Uniquely identifies each entry in alarm table. So when an alarm in the alarm table clears, the alarms located below the this cleared alarm will have to change their alarm index. Hence there will be holes in the alarm table. May not start with one and there will be some missing numbers. | |||
| OBJECT-TYPE | |||
| Integer32 | 1..2147483647 | ||
| cerent454AlarmObjectType | 1.3.6.1.4.1.3607.6.10.20.30.20.1.20 | ||
| This will indicate what is the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarm | |||
| OBJECT-TYPE | |||
| Cerent454EntityClass | |||
| cerent454AlarmSlotNumber | 1.3.6.1.4.1.3607.6.10.20.30.20.1.30 | ||
| This will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| cerent454AlarmPortNumber | 1.3.6.1.4.1.3607.6.10.20.30.20.1.40 | ||
| This will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| cerent454AlarmLineNumber | 1.3.6.1.4.1.3607.6.10.20.30.20.1.50 | ||
| This will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| cerent454AlarmObjectIndex | 1.3.6.1.4.1.3607.6.10.20.30.20.1.60 | ||
| Every alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this index is the index of the interface in the interface table. | |||
| OBJECT-TYPE | |||
| Integer32 | |||
| cerent454AlarmType | 1.3.6.1.4.1.3607.6.10.20.30.20.1.70 | ||
| Indicates what the exact nature of the alarm. See the Cerent454AlarmType TC for mapping details | |||
| OBJECT-TYPE | |||
| Cerent454AlarmType | |||
| cerent454AlarmState | 1.3.6.1.4.1.3607.6.10.20.30.20.1.80 | ||
| Specifies alarm severity and service affecting status ( SA/NSA ). Only {minor|major|critical}+{NA|NSA} will be represented here. | |||
| OBJECT-TYPE | |||
| CerentNotificationClass | |||
| cerent454AlarmTimeStamp | 1.3.6.1.4.1.3607.6.10.20.30.20.1.90 | ||
| Indicates when the alarm occurred. The value is number of ticks that has lasped since 1/1/1970 | |||
| OBJECT-TYPE | |||
| TimeStamp | |||
| cerent454Events | 1.3.6.1.4.1.3607.6.10.30 | ||
| Place holder for all notifications of Cisco ONS 15454 | |||
| OBJECT-IDENTITY | |||
| cerent454V2Events | 1.3.6.1.4.1.3607.6.10.30.0 | ||
| The sub-identifier has to be zero, as part of the interoperability agreement between SNMPv1 and SNMPv2 worlds. | |||
| OBJECT-IDENTITY | |||
| alarmUnknown | 1.3.6.1.4.1.3607.6.10.30.0.1 | ||
| alarm unknown | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| alarmCutoffIsInManualMode | 1.3.6.1.4.1.3607.6.10.30.0.10 | ||
| alarm cutoff is in manual mode | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failureDetectedExternalToTheNE | 1.3.6.1.4.1.3607.6.10.30.0.20 | ||
| failure detected External to the NE | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| externalError | 1.3.6.1.4.1.3607.6.10.30.0.30 | ||
| external error | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| excessiveSwitching | 1.3.6.1.4.1.3607.6.10.30.0.40 | ||
| excessive switching | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| terminationFailureSDCC | 1.3.6.1.4.1.3607.6.10.30.0.50 | ||
| SDCC Termination failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| incomingFailureCondition | 1.3.6.1.4.1.3607.6.10.30.0.60 | ||
| incoming failure condition | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| alarmIndicationSignal | 1.3.6.1.4.1.3607.6.10.30.0.70 | ||
| alarm indication signal | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| alarmIndicationSignalLine | 1.3.6.1.4.1.3607.6.10.30.0.80 | ||
| alarm indication signal LINE | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| alarmIndicationSignalPath | 1.3.6.1.4.1.3607.6.10.30.0.90 | ||
| alarm indication signal Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| alarmIndicationSignalVT | 1.3.6.1.4.1.3607.6.10.30.0.100 | ||
| alarm indication signal VT | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelFailureAPS | 1.3.6.1.4.1.3607.6.10.30.0.110 | ||
| channel failure APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelByteFailureAPS | 1.3.6.1.4.1.3607.6.10.30.0.120 | ||
| channel Byte failure APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelProtectionSwitchingChannelMatchFailureAPS | 1.3.6.1.4.1.3607.6.10.30.0.130 | ||
| channel Protection Switching Channel Match failure APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelAutomaticProtectionSwitchModeMismatchAPS | 1.3.6.1.4.1.3607.6.10.30.0.140 | ||
| channel Automatic Protection Switch Mode Mismatch APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelFarEndProtectionLineFailureAPS | 1.3.6.1.4.1.3607.6.10.30.0.150 | ||
| channel far end protection line failure APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelBLSRInconsistentAPSCode | 1.3.6.1.4.1.3607.6.10.30.0.160 | ||
| channel BLSR inconsistent APS code | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelBLSRImproperAPSCodeAPS | 1.3.6.1.4.1.3607.6.10.30.0.170 | ||
| channel BLSR Improper APS code APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelBLSRNodeIdMismatchAPS | 1.3.6.1.4.1.3607.6.10.30.0.180 | ||
| channel BLSR Node Id Mismatch APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelBLSRDefaultKAPS | 1.3.6.1.4.1.3607.6.10.30.0.190 | ||
| channel BLSR Default K APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| channelBLSRConnectionLossAPS | 1.3.6.1.4.1.3607.6.10.30.0.200 | ||
| channel BLSR Connection loss APS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| bipolarViolation | 1.3.6.1.4.1.3607.6.10.30.0.210 | ||
| bipolar Violation | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| carrierLossOnTheLAN | 1.3.6.1.4.1.3607.6.10.30.0.220 | ||
| carrier Loss on the LAN | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| concatenationErrorSTS | 1.3.6.1.4.1.3607.6.10.30.0.230 | ||
| concatenation error STS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| excessCollisionsOnTheLAN | 1.3.6.1.4.1.3607.6.10.30.0.240 | ||
| excess collisions on the LAN | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityCriticalAlarmCausedByDS3FacilityFailure | 1.3.6.1.4.1.3607.6.10.30.0.250 | ||
| facility critical alarm caused by DS3 facility failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndAIS | 1.3.6.1.4.1.3607.6.10.30.0.260 | ||
| far end AIS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndMultipleDS1LOSDetectedOnDS3 | 1.3.6.1.4.1.3607.6.10.30.0.270 | ||
| far end Multiple DS1 LOS detected on DS3 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndDS1EqptFailNonServiceAffecting | 1.3.6.1.4.1.3607.6.10.30.0.280 | ||
| far end DS1 eqpt fail non service affecting | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndDS1EqptFailServiceAffecting | 1.3.6.1.4.1.3607.6.10.30.0.290 | ||
| far end DS1 Eqpt fail service affecting | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndSingleDS1LOS | 1.3.6.1.4.1.3607.6.10.30.0.300 | ||
| far end Single DS1 LOS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndDS3EqptFailNonServiceAffecting | 1.3.6.1.4.1.3607.6.10.30.0.310 | ||
| far end DS3 Eqpt failure non service affecting | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndDS3EqptFailServiceAffecting | 1.3.6.1.4.1.3607.6.10.30.0.320 | ||
| far end DS3 Eqpt failure service affecting | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndCmnEqptFailNonServiceAffecting | 1.3.6.1.4.1.3607.6.10.30.0.330 | ||
| far end common Eqpt failure non service affecting | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndIDLE | 1.3.6.1.4.1.3607.6.10.30.0.340 | ||
| far end IDLE | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndLOS | 1.3.6.1.4.1.3607.6.10.30.0.350 | ||
| far end LOS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndLOF | 1.3.6.1.4.1.3607.6.10.30.0.360 | ||
| far end LOF | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| farEndBlockError | 1.3.6.1.4.1.3607.6.10.30.0.370 | ||
| far End Block Error | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| idleConditionDS3 | 1.3.6.1.4.1.3607.6.10.30.0.380 | ||
| idle Condition DS3 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfFrame | 1.3.6.1.4.1.3607.6.10.30.0.390 | ||
| loss of Frame | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfPointer | 1.3.6.1.4.1.3607.6.10.30.0.400 | ||
| loss of Pointer | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfPointerPath | 1.3.6.1.4.1.3607.6.10.30.0.410 | ||
| loss of Pointer Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfPointerVT | 1.3.6.1.4.1.3607.6.10.30.0.420 | ||
| loss of Pointer VT | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfSignal | 1.3.6.1.4.1.3607.6.10.30.0.430 | ||
| loss of Signal | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| outOfFrame | 1.3.6.1.4.1.3607.6.10.30.0.440 | ||
| out of Frame | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| pathSelectorInabilityToSwitchToAValidSignal | 1.3.6.1.4.1.3607.6.10.30.0.450 | ||
| path Selector inability to swtich to a valid signal | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| remoteAlarmIndication | 1.3.6.1.4.1.3607.6.10.30.0.460 | ||
| remote Alarm Indication | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| remoteFailureIndication | 1.3.6.1.4.1.3607.6.10.30.0.470 | ||
| remote Failure Indication | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| remoteFailureIndicationLine | 1.3.6.1.4.1.3607.6.10.30.0.480 | ||
| remote Failure Indication LINE | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| remoteFailureIndicationPath | 1.3.6.1.4.1.3607.6.10.30.0.490 | ||
| remote Failure Indication Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| remoteFailureIndicationVT | 1.3.6.1.4.1.3607.6.10.30.0.500 | ||
| remote Failure Indication VT | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityHasPassedBERThresholdForSignalDegrade | 1.3.6.1.4.1.3607.6.10.30.0.510 | ||
| facility has passed BER Threshold for Signal Degrade | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| severelyErroredFrame | 1.3.6.1.4.1.3607.6.10.30.0.520 | ||
| severely Errored Frame | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityHasPassedBERThresholdForSignalFailure | 1.3.6.1.4.1.3607.6.10.30.0.530 | ||
| facility has passed BER threshold for Signal Failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| signalLabelMismatchFailuresSONET | 1.3.6.1.4.1.3607.6.10.30.0.540 | ||
| signal Label Mismatch Failures SONET | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| signalLabelMismatchFailurePayloadDefectIndication | 1.3.6.1.4.1.3607.6.10.30.0.550 | ||
| signal Label Mismatch Failure Payload Defect Indication | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| signalLabelMismatchFailurePayloadDefectIndicationPath | 1.3.6.1.4.1.3607.6.10.30.0.560 | ||
| signal Label Mismatch Failure Payload Defect Indication Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| signalLabelMismatchFailurePayloadLabelMismatchPath | 1.3.6.1.4.1.3607.6.10.30.0.570 | ||
| signal Label Mismatch Failure Payload Label Mismatch Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| signalLabelMismatchFailurePayloadLabelMismatchVT | 1.3.6.1.4.1.3607.6.10.30.0.580 | ||
| signal Label Mismatch Failure Payload Label Mismatch VT | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| signalLabelMismatchFailureUnequippedPath | 1.3.6.1.4.1.3607.6.10.30.0.590 | ||
| signal Label Mismatch Failure Unequipped Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| signalLabelMismatchFailureUnequippedVT | 1.3.6.1.4.1.3607.6.10.30.0.600 | ||
| signal Label Mismatch Failure Unequipped VT | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnSynchronizationLink | 1.3.6.1.4.1.3607.6.10.30.0.610 | ||
| loss of timing on Synchronization link | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnAllSpecifiedSynchronizationLinks | 1.3.6.1.4.1.3607.6.10.30.0.620 | ||
| loss of timing on all specified synchronization links | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnPrimarySynchronizationLink | 1.3.6.1.4.1.3607.6.10.30.0.630 | ||
| loss of timing on primary synchronization link | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnSecondarySynchronizationLink | 1.3.6.1.4.1.3607.6.10.30.0.640 | ||
| loss of timing on secondary synchronization link | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnThirdSynchronizationLink | 1.3.6.1.4.1.3607.6.10.30.0.650 | ||
| loss of timing on third synchronization link | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnFourthSynchronizationLink | 1.3.6.1.4.1.3607.6.10.30.0.660 | ||
| loss of timing on fourth synchronization link | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnFifthSynchronizationLink | 1.3.6.1.4.1.3607.6.10.30.0.670 | ||
| loss of timing on fifth synchronization link | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lossOfTimingOnSixthSynchronizationLink | 1.3.6.1.4.1.3607.6.10.30.0.680 | ||
| loss of timing on sixth synchronization link | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failedToReceiveSynchronizationStatusMessage | 1.3.6.1.4.1.3607.6.10.30.0.690 | ||
| failed to receive Synchronization Status Message | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationStatusMessagesAreDisabledOnThisInterface | 1.3.6.1.4.1.3607.6.10.30.0.700 | ||
| synchronization Status Messages are disabled on this interface | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| primaryReferenceSourceStratum1Traceable | 1.3.6.1.4.1.3607.6.10.30.0.710 | ||
| primary Reference Source Stratum 1 Traceable | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizedTraceabilityUnknown | 1.3.6.1.4.1.3607.6.10.30.0.720 | ||
| synchronized Traceability Unknown | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| stratum2Traceable | 1.3.6.1.4.1.3607.6.10.30.0.730 | ||
| stratum 2 Traceable | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| transitNodeClockTraceable | 1.3.6.1.4.1.3607.6.10.30.0.740 | ||
| transit Node clock Traceable | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| stratum3ETraceable | 1.3.6.1.4.1.3607.6.10.30.0.750 | ||
| stratum 3E Traceable | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| stratum3Traceable | 1.3.6.1.4.1.3607.6.10.30.0.760 | ||
| stratum 3 Traceable | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| minimumClockTraceableSONET | 1.3.6.1.4.1.3607.6.10.30.0.770 | ||
| SONET Minimum clock Traceable | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| stratum4Traceable | 1.3.6.1.4.1.3607.6.10.30.0.780 | ||
| stratum 4 Traceable | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| doNotUseForSynchronization | 1.3.6.1.4.1.3607.6.10.30.0.790 | ||
| do not Use for Synchronization | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| reservedForNetworkSynchronizationUse | 1.3.6.1.4.1.3607.6.10.30.0.800 | ||
| reserved for Network Synchronization Use | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| outgoingFailureCondition | 1.3.6.1.4.1.3607.6.10.30.0.810 | ||
| outgoing failure condition | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| remoteDefectIndicationLine | 1.3.6.1.4.1.3607.6.10.30.0.820 | ||
| remote Defect Indication LINE | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| remoteDefectIndicationPath | 1.3.6.1.4.1.3607.6.10.30.0.830 | ||
| remote Defect Indication Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| freeRunningSynchronizationMode | 1.3.6.1.4.1.3607.6.10.30.0.840 | ||
| free Running Synchronization mode | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| holdoverSynchronizationMode | 1.3.6.1.4.1.3607.6.10.30.0.850 | ||
| holdover synchronization mode | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| fastStartSynchronizationMode | 1.3.6.1.4.1.3607.6.10.30.0.860 | ||
| fast Start synchronization mode | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| internalHardwareFaultOrFailure | 1.3.6.1.4.1.3607.6.10.30.0.870 | ||
| internal hardware fault or failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| errorInternalToTheNEDetected | 1.3.6.1.4.1.3607.6.10.30.0.880 | ||
| error Internal to the NE Detected | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| internalMessageError | 1.3.6.1.4.1.3607.6.10.30.0.890 | ||
| internal Message Error | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| mismatchOfEquipmentAndAttributes | 1.3.6.1.4.1.3607.6.10.30.0.900 | ||
| mismatch of Equipment and Attributes | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| watchdogTimerTimeout | 1.3.6.1.4.1.3607.6.10.30.0.910 | ||
| watchdog Timer Timeout | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| softwareFaultOrFailure | 1.3.6.1.4.1.3607.6.10.30.0.920 | ||
| software Fault or failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| softwareFaultDataIntegrityFault | 1.3.6.1.4.1.3607.6.10.30.0.930 | ||
| software Fault - Data integrity fault : The newly added provisioning or hardware has caused the database to grow beyond its limit. That is, the newly added object(s) in the system has(have) enough memory to exist onboard but too large to be saved in the database. | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| programFailure | 1.3.6.1.4.1.3607.6.10.30.0.940 | ||
| program failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentFailure | 1.3.6.1.4.1.3607.6.10.30.0.950 | ||
| control Equipment failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentPrimaryNonVolatileBackupMemoryFailure | 1.3.6.1.4.1.3607.6.10.30.0.960 | ||
| control Equipment Primary non volatile Backup Memory failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentSecondaryNonVolatileBackupMemoryFailure | 1.3.6.1.4.1.3607.6.10.30.0.970 | ||
| control Equipment Secondary non volatile Backup Memory failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentControlBusFailure | 1.3.6.1.4.1.3607.6.10.30.0.980 | ||
| control Equipment Control Bus failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentControlBus1Failure | 1.3.6.1.4.1.3607.6.10.30.0.990 | ||
| control Equipment Control Bus 1 failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentControlBus2Failure | 1.3.6.1.4.1.3607.6.10.30.0.1000 | ||
| control Equipment Control Bus 2 failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT1 | 1.3.6.1.4.1.3607.6.10.30.0.1010 | ||
| communication failure TCC A to Shelf SLOT 1 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT2 | 1.3.6.1.4.1.3607.6.10.30.0.1020 | ||
| communication failure TCC A to Shelf SLOT 2 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT3 | 1.3.6.1.4.1.3607.6.10.30.0.1030 | ||
| communication failure TCC A to Shelf SLOT 3 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT4 | 1.3.6.1.4.1.3607.6.10.30.0.1040 | ||
| communication failure TCC A to Shelf SLOT 4 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT5 | 1.3.6.1.4.1.3607.6.10.30.0.1050 | ||
| communication failure TCC A to Shelf SLOT 5 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT6 | 1.3.6.1.4.1.3607.6.10.30.0.1060 | ||
| communication failure TCC A to Shelf SLOT 6 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT7 | 1.3.6.1.4.1.3607.6.10.30.0.1070 | ||
| communication failure TCC A to Shelf SLOT 7 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT8 | 1.3.6.1.4.1.3607.6.10.30.0.1080 | ||
| communication failure TCC A to Shelf SLOT 8 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT9 | 1.3.6.1.4.1.3607.6.10.30.0.1090 | ||
| communication failure TCC A to Shelf SLOT 9 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT10 | 1.3.6.1.4.1.3607.6.10.30.0.1100 | ||
| communication failure TCC A to Shelf SLOT 10 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT11 | 1.3.6.1.4.1.3607.6.10.30.0.1110 | ||
| communication failure TCC A to Shelf SLOT 11 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT12 | 1.3.6.1.4.1.3607.6.10.30.0.1120 | ||
| communication failure TCC A to Shelf SLOT 12 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT13 | 1.3.6.1.4.1.3607.6.10.30.0.1130 | ||
| communication failure TCC A to Shelf SLOT 13 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT14 | 1.3.6.1.4.1.3607.6.10.30.0.1140 | ||
| communication failure TCC A to Shelf SLOT 14 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT15 | 1.3.6.1.4.1.3607.6.10.30.0.1150 | ||
| communication failure TCC A to Shelf SLOT 15 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT16 | 1.3.6.1.4.1.3607.6.10.30.0.1160 | ||
| communication failure TCC A to Shelf SLOT 16 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCAToShelfSLOT17 | 1.3.6.1.4.1.3607.6.10.30.0.1170 | ||
| communication failure TCC A to Shelf SLOT 17 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCPAToTCCJAprocessor | 1.3.6.1.4.1.3607.6.10.30.0.1180 | ||
| communication failure TCCP A to TCCJ A processor | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT1 | 1.3.6.1.4.1.3607.6.10.30.0.1190 | ||
| communication failure TCC B to Shelf SLOT 1 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT2 | 1.3.6.1.4.1.3607.6.10.30.0.1200 | ||
| communication failure TCC B to Shelf SLOT 2 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT3 | 1.3.6.1.4.1.3607.6.10.30.0.1210 | ||
| communication failure TCC B to Shelf SLOT 3 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT4 | 1.3.6.1.4.1.3607.6.10.30.0.1220 | ||
| communication failure TCC B to Shelf SLOT 4 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT5 | 1.3.6.1.4.1.3607.6.10.30.0.1230 | ||
| communication failure TCC B to Shelf SLOT 5 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT6 | 1.3.6.1.4.1.3607.6.10.30.0.1240 | ||
| communication failure TCC B to Shelf SLOT 6 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT7 | 1.3.6.1.4.1.3607.6.10.30.0.1250 | ||
| communication failure TCC B to Shelf SLOT 7 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT8 | 1.3.6.1.4.1.3607.6.10.30.0.1260 | ||
| communication failure TCC B to Shelf SLOT 8 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT9 | 1.3.6.1.4.1.3607.6.10.30.0.1270 | ||
| communication failure TCC B to Shelf SLOT 9 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT10 | 1.3.6.1.4.1.3607.6.10.30.0.1280 | ||
| communication failure TCC B to Shelf SLOT 10 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT11 | 1.3.6.1.4.1.3607.6.10.30.0.1290 | ||
| communication failure TCC B to Shelf SLOT 11 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT12 | 1.3.6.1.4.1.3607.6.10.30.0.1300 | ||
| communication failure TCC B to Shelf SLOT 12 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT13 | 1.3.6.1.4.1.3607.6.10.30.0.1310 | ||
| communication failure TCC B to Shelf SLOT 13 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT14 | 1.3.6.1.4.1.3607.6.10.30.0.1320 | ||
| communication failure TCC B to Shelf SLOT 14 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT15 | 1.3.6.1.4.1.3607.6.10.30.0.1330 | ||
| communication failure TCC B to Shelf SLOT 15 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT16 | 1.3.6.1.4.1.3607.6.10.30.0.1340 | ||
| communication failure TCC B to Shelf SLOT 16 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCBToShelfSLOT17 | 1.3.6.1.4.1.3607.6.10.30.0.1350 | ||
| communication failure TCC B to Shelf SLOT 17 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| communicationFailureTCCPBToTCCJAprocessor | 1.3.6.1.4.1.3607.6.10.30.0.1360 | ||
| communication failure TCCP B to TCCJ A processor | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentControlCommunicationsEquipmentFailure | 1.3.6.1.4.1.3607.6.10.30.0.1370 | ||
| control Equipment Control Communications equipment failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentControlProcessorFailure | 1.3.6.1.4.1.3607.6.10.30.0.1380 | ||
| control Equipment Control processor failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| controlEquipmentWorkingMemoryFailure | 1.3.6.1.4.1.3607.6.10.30.0.1390 | ||
| control Equipment Working memory failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailure | 1.3.6.1.4.1.3607.6.10.30.0.1400 | ||
| interconnection Equipment failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus1Working | 1.3.6.1.4.1.3607.6.10.30.0.1410 | ||
| interconnection Equipment failure Payload Bus 1 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus2Working | 1.3.6.1.4.1.3607.6.10.30.0.1420 | ||
| interconnection Equipment failure Payload Bus 2 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus3Working | 1.3.6.1.4.1.3607.6.10.30.0.1430 | ||
| interconnection Equipment failure Payload Bus 3 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus4Working | 1.3.6.1.4.1.3607.6.10.30.0.1440 | ||
| interconnection Equipment failure Payload Bus 4 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus5Working | 1.3.6.1.4.1.3607.6.10.30.0.1450 | ||
| interconnection Equipment failure Payload Bus 5 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus6Working | 1.3.6.1.4.1.3607.6.10.30.0.1460 | ||
| interconnection Equipment failure Payload Bus 6 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus7Working | 1.3.6.1.4.1.3607.6.10.30.0.1470 | ||
| interconnection Equipment failure Payload Bus 7 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus8Working | 1.3.6.1.4.1.3607.6.10.30.0.1480 | ||
| interconnection Equipment failure Payload Bus 8 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus9Working | 1.3.6.1.4.1.3607.6.10.30.0.1490 | ||
| interconnection Equipment failure Payload Bus 9 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus10Working | 1.3.6.1.4.1.3607.6.10.30.0.1500 | ||
| interconnection Equipment failure Payload Bus 10 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus11Working | 1.3.6.1.4.1.3607.6.10.30.0.1510 | ||
| interconnection Equipment failure Payload Bus 11 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus12Working | 1.3.6.1.4.1.3607.6.10.30.0.1520 | ||
| interconnection Equipment failure Payload Bus 12 Working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus1Protect | 1.3.6.1.4.1.3607.6.10.30.0.1530 | ||
| interconnection Equipment failure Payload Bus 1 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus2Protect | 1.3.6.1.4.1.3607.6.10.30.0.1540 | ||
| interconnection Equipment failure Payload Bus 2 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus3Protect | 1.3.6.1.4.1.3607.6.10.30.0.1550 | ||
| interconnection Equipment failure Payload Bus 3 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus4Protect | 1.3.6.1.4.1.3607.6.10.30.0.1560 | ||
| interconnection Equipment failure Payload Bus 4 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus5Protect | 1.3.6.1.4.1.3607.6.10.30.0.1570 | ||
| interconnection Equipment failure Payload Bus 5 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus6Protect | 1.3.6.1.4.1.3607.6.10.30.0.1580 | ||
| interconnection Equipment failure Payload Bus 6 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus7Protect | 1.3.6.1.4.1.3607.6.10.30.0.1590 | ||
| interconnection Equipment failure Payload Bus 7 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus8Protect | 1.3.6.1.4.1.3607.6.10.30.0.1600 | ||
| interconnection Equipment failure Payload Bus 8 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus9Protect | 1.3.6.1.4.1.3607.6.10.30.0.1610 | ||
| interconnection Equipment failure Payload Bus 9 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus10Protect | 1.3.6.1.4.1.3607.6.10.30.0.1620 | ||
| interconnection Equipment failure Payload Bus 10 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus11Protect | 1.3.6.1.4.1.3607.6.10.30.0.1630 | ||
| interconnection Equipment failure Payload Bus 11 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEquipmentFailurePayloadBus12Protect | 1.3.6.1.4.1.3607.6.10.30.0.1640 | ||
| interconnection Equipment failure Payload Bus 12 Protect | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| interconnectionEqptTimeSlotInterchangeEqptFailure | 1.3.6.1.4.1.3607.6.10.30.0.1650 | ||
| interconnection Eqpt Time slot interchange eqpt failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| criticalAlarmCausedByEquipmentFailure | 1.3.6.1.4.1.3607.6.10.30.0.1660 | ||
| critical alarm caused by equipment failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| equipmentFailureHighTemperature | 1.3.6.1.4.1.3607.6.10.30.0.1670 | ||
| equipment failure High temperature | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| equipmentFailureInvalidMACAddress | 1.3.6.1.4.1.3607.6.10.30.0.1680 | ||
| equipment failure Invalid MAC Address | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| equipmentFailureBoardFailure | 1.3.6.1.4.1.3607.6.10.30.0.1690 | ||
| equipment failure Board Failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| equipmentFailureDiagnosticsFailure | 1.3.6.1.4.1.3607.6.10.30.0.1700 | ||
| equipment failure Diagnostics Failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| equipmentFailureMediumAccessControl | 1.3.6.1.4.1.3607.6.10.30.0.1710 | ||
| equipment failure Medium Access Control | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityTerminationEquipmentFailure | 1.3.6.1.4.1.3607.6.10.30.0.1720 | ||
| facility Termination equipment failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityTerminationEquipmentAutomaticLaserShutdown | 1.3.6.1.4.1.3607.6.10.30.0.1730 | ||
| facility Termination Equipment Automatic Laser Shutdown | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failureToReleaseFromProtection | 1.3.6.1.4.1.3607.6.10.30.0.1740 | ||
| failure To Release from protection | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityTerminationEquipmentReceiverFailure | 1.3.6.1.4.1.3607.6.10.30.0.1750 | ||
| facility Termination equipment Receiver failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityTerminationEquipmentTransmitFailure | 1.3.6.1.4.1.3607.6.10.30.0.1760 | ||
| facility Termination equipment Transmit failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityTerminationEquipmentReceiverMissing | 1.3.6.1.4.1.3607.6.10.30.0.1770 | ||
| facility Termination equipment Receiver missing | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| facilityTerminationEquipmentTransmitterMissing | 1.3.6.1.4.1.3607.6.10.30.0.1780 | ||
| facility Termination equipment Transmitter missing | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failureToSwitchToProtection | 1.3.6.1.4.1.3607.6.10.30.0.1790 | ||
| failure To Switch to protection | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failureToSwitchToProtectionRing | 1.3.6.1.4.1.3607.6.10.30.0.1800 | ||
| failure To Switch to protection Ring | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failureToSwitchToProtectionSpan | 1.3.6.1.4.1.3607.6.10.30.0.1810 | ||
| failure To Switch to protection Span | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failureToSwitchToProtectionPath | 1.3.6.1.4.1.3607.6.10.30.0.1820 | ||
| failure to Switch to protection Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| failureOfCoolingFanTray | 1.3.6.1.4.1.3607.6.10.30.0.1830 | ||
| failure of cooling fan tray | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| equipmentUnitPlugIn | 1.3.6.1.4.1.3607.6.10.30.0.1840 | ||
| equipment unit plug in | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| powerFailureDetectedInternalToNE | 1.3.6.1.4.1.3607.6.10.30.0.1850 | ||
| power failure detected internal to NE | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| powerFailureFuseAlarm | 1.3.6.1.4.1.3607.6.10.30.0.1860 | ||
| power failure Fuse Alarm | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationUnitFailure | 1.3.6.1.4.1.3607.6.10.30.0.1870 | ||
| synchronization unit failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchingEquipmentFailure | 1.3.6.1.4.1.3607.6.10.30.0.1880 | ||
| synchronization switching Equipment failure | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| equipmentUnitUnplug | 1.3.6.1.4.1.3607.6.10.30.0.1890 | ||
| equipment unit un plug | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopback | 1.3.6.1.4.1.3607.6.10.30.0.1900 | ||
| loop back | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackDueToFEACCommandDS1 | 1.3.6.1.4.1.3607.6.10.30.0.1910 | ||
| loopback due to FEAC command DS1 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackCommandSentToFarEndDS1 | 1.3.6.1.4.1.3607.6.10.30.0.1920 | ||
| loopback Command sent to Far End DS1 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackDueToFEACCommandDS3 | 1.3.6.1.4.1.3607.6.10.30.0.1930 | ||
| loopback due to FEAC command DS3 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackCommandSentToFarEndDS3 | 1.3.6.1.4.1.3607.6.10.30.0.1940 | ||
| loopback Command sent to Far End DS3 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackDueToFarEndCommandDS2 | 1.3.6.1.4.1.3607.6.10.30.0.1950 | ||
| loopback due to Far End Command DS2 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackCommandSentToFarEndDS2 | 1.3.6.1.4.1.3607.6.10.30.0.1960 | ||
| loopback Command sent to Far End DS2 | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackFacility | 1.3.6.1.4.1.3607.6.10.30.0.1970 | ||
| loop back facility | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackNetwork | 1.3.6.1.4.1.3607.6.10.30.0.1980 | ||
| loop back Network | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| loopbackTerminal | 1.3.6.1.4.1.3607.6.10.30.0.1990 | ||
| loop back Terminal | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manuallyCausedAbnormalCondition | 1.3.6.1.4.1.3607.6.10.30.0.2000 | ||
| manually caused abnormal condition | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| newRootDiscoveredInBridgedNetwork | 1.3.6.1.4.1.3607.6.10.30.0.2010 | ||
| new Root discovered in bridged network | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| topologyChangeDiscoveredInBridgedNetwork | 1.3.6.1.4.1.3607.6.10.30.0.2020 | ||
| topology change discovered in bridged network | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| normalCondition | 1.3.6.1.4.1.3607.6.10.30.0.2030 | ||
| normal condition | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| embeddedOperationsChannelFailureLinkDown | 1.3.6.1.4.1.3607.6.10.30.0.2040 | ||
| embedded Operations Channel failure link down | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| peerStateMismatch | 1.3.6.1.4.1.3607.6.10.30.0.2050 | ||
| peer state mismatch | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| proceduralError | 1.3.6.1.4.1.3607.6.10.30.0.2060 | ||
| procedural Error | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| proceduralErrorImproperRemoval | 1.3.6.1.4.1.3607.6.10.30.0.2070 | ||
| procedural Error Improper Removal | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| proceduralErrorDuplicateNodeID | 1.3.6.1.4.1.3607.6.10.30.0.2080 | ||
| procedural Error Duplicate Node ID | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| proceduralErrorBLSROutOfSync | 1.3.6.1.4.1.3607.6.10.30.0.2090 | ||
| procedural Error BLSR out of sync | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| resynchronizedBLSRTables | 1.3.6.1.4.1.3607.6.10.30.0.2100 | ||
| BLSR tables resynchronized | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| protectionUnitNotAvailable | 1.3.6.1.4.1.3607.6.10.30.0.2110 | ||
| protection unit not available | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| performanceMonitorThresholdCrossingAlert | 1.3.6.1.4.1.3607.6.10.30.0.2120 | ||
| performance Monitor Threshold Crossing Alert | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| occurrenceOfAProtectionSwitchingEvent | 1.3.6.1.4.1.3607.6.10.30.0.2130 | ||
| occurrence of a protection switching event | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| recoveryOrServiceProtectionActionHasBeenInitiated | 1.3.6.1.4.1.3607.6.10.30.0.2140 | ||
| recovery or service protection action has been initiated | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| automaticSystemReset | 1.3.6.1.4.1.3607.6.10.30.0.2150 | ||
| automatic system Reset | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| automacticUPSRSwitchCausedByAIS | 1.3.6.1.4.1.3607.6.10.30.0.2160 | ||
| automactic UPSR switch caused by AIS | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| automacticUPSRSwitchCausedByLOP | 1.3.6.1.4.1.3607.6.10.30.0.2170 | ||
| automactic UPSR switch caused by Lop | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| automacticUPSRSwitchCausedByUneq | 1.3.6.1.4.1.3607.6.10.30.0.2180 | ||
| automactic UPSR switch caused by Uneq | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| automacticUPSRSwitchCausedByPDI | 1.3.6.1.4.1.3607.6.10.30.0.2190 | ||
| automactic UPSR switch caused by PDI | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| automacticUPSRSwitchCausedBySfber | 1.3.6.1.4.1.3607.6.10.30.0.2200 | ||
| automactic UPSR switch caused by Sfber | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| automacticUPSRSwitchCausedBySdber | 1.3.6.1.4.1.3607.6.10.30.0.2210 | ||
| automactic UPSR switch caused by Sdber | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| coldRestart | 1.3.6.1.4.1.3607.6.10.30.0.2220 | ||
| cold Restart | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptForcedSwitchedToWorking | 1.3.6.1.4.1.3607.6.10.30.0.2230 | ||
| working facility or eqpt forced switched to working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptForcedSwitchedToWorkingRing | 1.3.6.1.4.1.3607.6.10.30.0.2240 | ||
| working facility or eqpt forced switched to working Ring | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptForcedSwitchedToWorkingSpan | 1.3.6.1.4.1.3607.6.10.30.0.2250 | ||
| working facility or eqpt forced switched to working Span | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptForcedSwitchedProtectionUnit | 1.3.6.1.4.1.3607.6.10.30.0.2260 | ||
| working facility or eqpt forced switched protection unit | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptForcedSwitchedProtectionUnitRing | 1.3.6.1.4.1.3607.6.10.30.0.2270 | ||
| working facility or eqpt forced switched protection unit Ring | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptForcedSwitchedProtectionUnitSpan | 1.3.6.1.4.1.3607.6.10.30.0.2280 | ||
| working facility or eqpt forced switched protection unit Span | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptForcedSwitchedProtectionUnitPath | 1.3.6.1.4.1.3607.6.10.30.0.2290 | ||
| working facility or eqpt forced switched protection unit Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| initializationInitiated | 1.3.6.1.4.1.3607.6.10.30.0.2300 | ||
| initialization initiated | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutOfProtection | 1.3.6.1.4.1.3607.6.10.30.0.2310 | ||
| lockout of Protection | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutOfProtectionRing | 1.3.6.1.4.1.3607.6.10.30.0.2320 | ||
| lockout of Protection Ring | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutOfProtectionSpan | 1.3.6.1.4.1.3607.6.10.30.0.2330 | ||
| lockout of Protection Span | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutOfProtectionPath | 1.3.6.1.4.1.3607.6.10.30.0.2340 | ||
| lockout of Protection Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutOfWorking | 1.3.6.1.4.1.3607.6.10.30.0.2350 | ||
| lockout of working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutOfWorkingRing | 1.3.6.1.4.1.3607.6.10.30.0.2360 | ||
| lockout of working Ring | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutOfWorkingSpan | 1.3.6.1.4.1.3607.6.10.30.0.2370 | ||
| lockout of working Span | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSystemReset | 1.3.6.1.4.1.3607.6.10.30.0.2380 | ||
| manual system Reset | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSynchronizationSwitchToInternalClock | 1.3.6.1.4.1.3607.6.10.30.0.2390 | ||
| manual synchronization switch to internal clock | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSynchronizationSwitchToPrimaryRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2400 | ||
| manual synchronization Switch To Primary refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSynchronizationSwitchToSecondRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2410 | ||
| manual synchronization Switch To Second refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSynchronizationSwitchToThirdRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2420 | ||
| manual synchronization Switch To Third refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSynchronizationSwitchToFourthRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2430 | ||
| manual synchronization Switch To Fourth refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSynchronizationSwitchToFifthRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2440 | ||
| manual synchronization Switch To Fifth refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSynchronizationSwitchToSixthRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2450 | ||
| manual synchronization Switch To Sixth refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSwitchOfWorkingFacilityOrEqptToProtectionRing | 1.3.6.1.4.1.3607.6.10.30.0.2460 | ||
| manualSwitch of working facility or eqpt to protection Ring | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSwitchOfWorkingFacilityOrEqptToProtectionSpan | 1.3.6.1.4.1.3607.6.10.30.0.2470 | ||
| manualSwitch of working facility or eqpt to protection Span | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSwitchOfWorkingFacilityOrEqptToProtection | 1.3.6.1.4.1.3607.6.10.30.0.2480 | ||
| manualSwitch of working facility or eqpt to protection | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSwitchOfWorkingFacilityOrEqptToProtectionUnit | 1.3.6.1.4.1.3607.6.10.30.0.2490 | ||
| manualSwitch of Working facility or eqpt to Protection unit | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptManualSwitchToProtectionUnitRing | 1.3.6.1.4.1.3607.6.10.30.0.2500 | ||
| working facility or eqpt manualSwitch to Protection unit Ring | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEqptManualSwitchToProtectionUnitSpan | 1.3.6.1.4.1.3607.6.10.30.0.2510 | ||
| working facility or eqpt manualSwitch to Protection unit Span | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSwitchOfWorkingFacilityOrEqptToProtectionPath | 1.3.6.1.4.1.3607.6.10.30.0.2520 | ||
| manualSwitch of working facility or eqpt to Protection Path | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| powerFailureRestart | 1.3.6.1.4.1.3607.6.10.30.0.2530 | ||
| power failure Restart | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| ringIsSquelchingTraffic | 1.3.6.1.4.1.3607.6.10.30.0.2540 | ||
| ring is squelching traffic | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| softwareDownloadInProgress | 1.3.6.1.4.1.3607.6.10.30.0.2550 | ||
| software download in progress | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchToInternalClock | 1.3.6.1.4.1.3607.6.10.30.0.2560 | ||
| synchronization Switch To Internal clock | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchToPrimaryRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2570 | ||
| synchronization Switch To Primary refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchToSecondRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2580 | ||
| synchronization Switch To Second refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchToThirdRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2590 | ||
| synchronization Switch To Third refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchToFourthRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2600 | ||
| synchronization Switch To Fourth refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchToFifthRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2610 | ||
| synchronization Switch To Fifth refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| synchronizationSwitchToSixthRefernce | 1.3.6.1.4.1.3607.6.10.30.0.2620 | ||
| synchronization Switch To Sixth refernce | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| systemReboot | 1.3.6.1.4.1.3607.6.10.30.0.2630 | ||
| system reboot | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEquipmentSwitchedBackToWorking | 1.3.6.1.4.1.3607.6.10.30.0.2640 | ||
| working facility or equipment switched back to working | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| workingFacilityOrEquipmentSwitchedToProtectionUnit | 1.3.6.1.4.1.3607.6.10.30.0.2650 | ||
| working facility or equipment switched to protection unit | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| warmRestart | 1.3.6.1.4.1.3607.6.10.30.0.2660 | ||
| warm Restart | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| isInWaitToRestoreStateSONETLine | 1.3.6.1.4.1.3607.6.10.30.0.2670 | ||
| SONET line is in Wait To Restore state | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| manualSwitchRequestOnFacilityOrEquipment | 1.3.6.1.4.1.3607.6.10.30.0.2680 | ||
| manual switch request on facility or equipment | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| forceSwitchRequestOnFacilityOrEquipment | 1.3.6.1.4.1.3607.6.10.30.0.2690 | ||
| force switch request on facility or equipment | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| lockoutSwitchRequestOnFacilityOrEquipment | 1.3.6.1.4.1.3607.6.10.30.0.2700 | ||
| lockout switch request on facility or equipment | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| rmonHistoriesAndAlarmsReset | 1.3.6.1.4.1.3607.6.10.30.0.2710 | ||
| RMON histories and alarms have been reset due to chipset reboot | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| freeMemoryOnCardVeryLow | 1.3.6.1.4.1.3607.6.10.30.0.2830 | ||
| Free memory on the card is very low | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| freeMemoryOnCardAlmostGone | 1.3.6.1.4.1.3607.6.10.30.0.2840 | ||
| Free memory on the card is almost gone | |||
| NOTIFICATION-TYPE | |||
| cerentNodeTime | |||
| cerent454AlarmState | |||
| cerent454AlarmObjectType | |||
| cerent454AlarmObjectIndex | |||
| cerent454AlarmSlotNumber | |||
| cerent454AlarmPortNumber | |||
| cerent454AlarmLineNumber | |||
| cerentCommonObjects | 1.3.6.1.4.1.3607.6.10.100 | ||
| The objects here are expected to be used by all Cisco OTBU Products. These will be mixed with specific objects of the product-specific branch. | |||
| OBJECT-IDENTITY | |||
| cerentCommonObjectsGroup | 1.3.6.1.4.1.3607.6.10.100.10 | ||
| The group to combine all the Cisco OTBU common objects | |||
| OBJECT-IDENTITY | |||
| cerentEnableNotification | 1.3.6.1.4.1.3607.6.10.100.10.10 | ||
| This variable indicates whether the system produces notifications. A value=FALSE will prevent notifications from being sent by this system. | |||
| OBJECT-TYPE | |||
| TruthValue | |||
| cerentNodeTime | 1.3.6.1.4.1.3607.6.10.100.10.20 | ||
| Indicates current local time as reflected by the Cisco OTBU equipment. The format this scalar is YYYYMMDDhhmmss{S/D}. E.g., 20011103133453D means 1:34:53 PM PDT on 03/Nov/2001 19990614095436S means 9:54:36 AM PST on 14/Jun/1999. If the last octet is S then the time is standard time. Otherwise it is D to indicate it is daylight saving time, if applicable | |||
| OBJECT-TYPE | |||
| DisplayString | |||
| cerentNotificationsSent | 1.3.6.1.4.1.3607.6.10.100.10.30 | ||
| A count of v1+v2 notifications sent out by the agent. Resets to zero after cold/warm start. | |||
| OBJECT-TYPE | |||
| Counter32 | |||
| cerentLastChangeTime | 1.3.6.1.4.1.3607.6.10.100.10.40 | ||
| The value of sysUpTime at the time a conceptual row is created or deleted in cerent454AlarmTable | |||
| OBJECT-TYPE | |||
| TimeStamp | |||
| cerentCommonEvents | 1.3.6.1.4.1.3607.6.10.200 | ||
| This branch is similar to cerentCommonObjects, except that this will have only events | |||
| OBJECT-IDENTITY | |||
| Cerent454AlarmType | |||
| This TC is used by the NMS to map the alarm type received by the trap and and display the string shown in LHS. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | alarmUnknown(1), alarmCutoffIsInManualMode(10), failureDetectedexternalToTheNE(20), externalError(30), excessiveSwitching(40), terminationFailureSDCC(50), incomingFailureCondition(60), alarmIndicationSignal(70), alarmIndicationSignalLine(80), alarmIndicationSignalPath(90), alarmIndicationSignalVT(100), channelFailureAPS(110), channelByteFailureAPS(120), channelProtectionSwitchingChannelMatchFailureAPS(130), channelAutomaticProtectionSwitchModeMismatchAPS(140), channelFarEndProtectionLineFailureAPS(150), channelBLSRInconsistentAPSCode(160), channelBLSRImproperAPSCodeAPS(170), channelBLSRNodeIdMismatchAPS(180), channelBLSRDefaultKAPS(190), channelBLSRConnectionLossAPS(200), bipolarViolation(210), carrierLossOnTheLAN(220), concatenationErrorSTS(230), excessCollisionsOnTheLAN(240), facilityCriticalAlarmCausedByDS3FacilityFailure(250), farEndAIS(260), farEndMultipleDS1LOSDetectedOnDS3(270), farEndDS1EqptFailNonServiceAffecting(280), farEndDS1EqptFailServiceAffecting(290), farEndSingleDS1LOS(300), farEndDS3EqptFailNonServiceAffecting(310), farEndDS3EqptFailServiceAffecting(320), farEndCmnEqptFailNonServiceAffecting(330), farEndIDLE(340), farEndLOS(350), farEndLOF(360), farEndBlockError(370), idleConditionDS3(380), lossOfFrame(390), lossOfPointer(400), lossOfPointerPath(410), lossOfPointerVT(420), lossOfSignal(430), outOfFrame(440), pathSelectorInabilityToSwitchToAValidSignal(450), remoteAlarmIndication(460), remoteFailureIndication(470), remoteFailureIndicationLine(480), remoteFailureIndicationPath(490), remoteFailureIndicationVT(500), facilityHasPassedBERThresholdForSignalDegrade(510), severelyErroredFrame(520), facilityHasPassedBERThresholdForSignalFailure(530), signalLabelMismatchFailuresSONET(540), signalLabelMismatchFailurePayloadDefectIndication(550), signalLabelMismatchFailurePayloadDefectIndicationPath(560), signalLabelMismatchFailurePayloadLabelMismatchPath(570), signalLabelMismatchFailurePayloadLabelMismatchVT(580), signalLabelMismatchFailureUnequippedPath(590), signalLabelMismatchFailureUnequippedVT(600), lossOfTimingOnSynchronizationLink(610), lossOfTimingOnAllSpecifiedSynchronizationLinks(620), lossOfTimingOnPrimarySynchronizationLink(630), lossOfTimingOnSecondarySynchronizationLink(640), lossOfTimingOnThirdSynchronizationLink(650), lossOfTimingOnFourthSynchronizationLink(660), lossOfTimingOnFifthSynchronizationLink(670), lossOfTimingOnSixthSynchronizationLink(680), failedToReceiveSynchronizationStatusMessage(690), synchronizationStatusMessagesAreDisabledOnThisInterface(700), primaryReferenceSourceStratum1Traceable(710), synchronizedTraceabilityUnknown(720), stratum2Traceable(730), transiTNodeClockTraceable(740), stratum3ETraceable(750), stratum3Traceable(760), minimumClockTraceableSONET(770), stratum4Traceable(780), doNotUseForSynchronization(790), reservedForNetworkSynchronizationUse(800), outgoingFailureCondition(810), remoteDefectIndicationLine(820), remoteDefectIndicationPath(830), freeRunningSynchronizationMode(840), holdoverSynchronizationMode(850), fastStartSynchronizationMode(860), internalHardwareFaultOrFailure(870), errorInternalToTheNEDetected(880), internalMessageError(890), mismatchOfEquipmentAndAttributes(900), watchdogTimerTimeout(910), softwareFaultOrFailure(920), softwareFaultDataIntegrityFault(930), programFailure(940), controlEquipmentFailure(950), controlEquipmentPrimaryNonVolatileBackupMemoryFailure(960), controlEquipmentSecondaryNonVolatileBackupMemoryFailure(970), controlEquipmentControlBusFailure(980), controlEquipmentControlBus1Failure(990), controlEquipmentControlBus2Failure(1000), communicationFailureTCCAToShelfSLOT1(1010), communicationFailureTCCAToShelfSLOT2(1020), communicationFailureTCCAToShelfSLOT3(1030), communicationFailureTCCAToShelfSLOT4(1040), communicationFailureTCCAToShelfSLOT5(1050), communicationFailureTCCAToShelfSLOT6(1060), communicationFailureTCCAToShelfSLOT7(1070), communicationFailureTCCAToShelfSLOT8(1080), communicationFailureTCCAToShelfSLOT9(1090), communicationFailureTCCAToShelfSLOT10(1100), communicationFailureTCCAToShelfSLOT11(1110), communicationFailureTCCAToShelfSLOT12(1120), communicationFailureTCCAToShelfSLOT13(1130), communicationFailureTCCAToShelfSLOT14(1140), communicationFailureTCCAToShelfSLOT15(1150), communicationFailureTCCAToShelfSLOT16(1160), communicationFailureTCCAToShelfSLOT17(1170), communicationFailureTCCPAToTCCJAprocessor(1180), communicationFailureTCCBToShelfSLOT1(1190), communicationFailureTCCBToShelfSLOT2(1200), communicationFailureTCCBToShelfSLOT3(1210), communicationFailureTCCBToShelfSLOT4(1220), communicationFailureTCCBToShelfSLOT5(1230), communicationFailureTCCBToShelfSLOT6(1240), communicationFailureTCCBToShelfSLOT7(1250), communicationFailureTCCBToShelfSLOT8(1260), communicationFailureTCCBToShelfSLOT9(1270), communicationFailureTCCBToShelfSLOT10(1280), communicationFailureTCCBToShelfSLOT11(1290), communicationFailureTCCBToShelfSLOT12(1300), communicationFailureTCCBToShelfSLOT13(1310), communicationFailureTCCBToShelfSLOT14(1320), communicationFailureTCCBToShelfSLOT15(1330), communicationFailureTCCBToShelfSLOT16(1340), communicationFailureTCCBToShelfSLOT17(1350), communicationFailureTCCPBToTCCJAprocessor(1360), controlEquipmentControlCommunicationsEquipmentFailure(1370), controlEquipmentControlProcessorFailure(1380), controlEquipmentWorkingMemoryFailure(1390), interconnectionEquipmentFailure(1400), interconnectionEquipmentFailurePayloadBus1Working(1410), interconnectionEquipmentFailurePayloadBus2Working(1420), interconnectionEquipmentFailurePayloadBus3Working(1430), interconnectionEquipmentFailurePayloadBus4Working(1440), interconnectionEquipmentFailurePayloadBus5Working(1450), interconnectionEquipmentFailurePayloadBus6Working(1460), interconnectionEquipmentFailurePayloadBus7Working(1470), interconnectionEquipmentFailurePayloadBus8Working(1480), interconnectionEquipmentFailurePayloadBus9Working(1490), interconnectionEquipmentFailurePayloadBus10Working(1500), interconnectionEquipmentFailurePayloadBus11Working(1510), interconnectionEquipmentFailurePayloadBus12Working(1520), interconnectionEquipmentFailurePayloadBus1Protect(1530), interconnectionEquipmentFailurePayloadBus2Protect(1540), interconnectionEquipmentFailurePayloadBus3Protect(1550), interconnectionEquipmentFailurePayloadBus4Protect(1560), interconnectionEquipmentFailurePayloadBus5Protect(1570), interconnectionEquipmentFailurePayloadBus6Protect(1580), interconnectionEquipmentFailurePayloadBus7Protect(1590), interconnectionEquipmentFailurePayloadBus8Protect(1600), interconnectionEquipmentFailurePayloadBus9Protect(1610), interconnectionEquipmentFailurePayloadBus10Protect(1620), interconnectionEquipmentFailurePayloadBus11Protect(1630), interconnectionEquipmentFailurePayloadBus12Protect(1640), interconnectionEqptTimeSlotInterchangeEqptFailure(1650), criticalAlarmCausedByEquipmentFailure(1660), equipmentFailureHighTemperature(1670), equipmentFailureInvalidMACAddress(1680), equipmentFailureBoardFailure(1690), equipmentFailureDiagnosticsFailure(1700), equipmentFailureMediumAccessControl(1710), facilityTerminationEquipmentFailure(1720), facilityTerminationEquipmentAutomaticLaserShutdown(1730), failureToReleaseFromProtection(1740), facilityTerminationEquipmentReceiverFailure(1750), facilityTerminationEquipmentTransmitFailure(1760), facilityTerminationEquipmentReceiverMissing(1770), facilityTerminationEquipmentTransmitterMissing(1780), failureToSwitchToProtection(1790), failureToSwitchToProtectionRing(1800), failureToSwitchToProtectionSpan(1810), failureToSwitchToProtectionPath(1820), failureOfCoolingFanTray(1830), equipmentUnitPlugIn(1840), powerFailureDetectedInternalToNE(1850), powerFailureFuseAlarm(1860), synchronizationUnitFailure(1870), synchronizationSwitchingEquipmentFailure(1880), equipmentUnitUnplug(1890), loopback(1900), loopbackDueToFEACCommandDS1(1910), loopbackCommandSentToFarEndDS1(1920), loopbackDueToFEACCommandDS3(1930), loopbackCommandSentToFarEndDS3(1940), loopbackDueToFarEndCommandDS2(1950), loopbackCommandSentToFarEndDS2(1960), loopbackFacility(1970), loopbackNetwork(1980), loopbackTerminal(1990), manuallyCausedAbnormalCondition(2000), newRootDiscoveredInBridgedNetwork(2010), topologyChangeDiscoveredInBridgedNetwork(2020), normalCondition(2030), embeddedOperationsChannelFailureLinkDown(2040), peerStateMismatch(2050), proceduralError(2060), proceduralErrorImproperRemoval(2070), proceduralErrorDuplicateNodeID(2080), proceduralErrorBLSROutOfSync(2090), resynchronizedBLSRTables(2100), protectionUnitNotAvailable(2110), performanceMonitorThresholdCrossingAlert(2120), occurrenceOfAProtectionSwitchingEvent(2130), recoveryOrServiceProtectionActionHasBeenInitiated(2140), automaticSystemReset(2150), automacticUPSRSwitchCausedByAIS(2160), automacticUPSRSwitchCausedByLOP(2170), automacticUPSRSwitchCausedByUneq(2180), automacticUPSRSwitchCausedByPDI(2190), automacticUPSRSwitchCausedBySfber(2200), automacticUPSRSwitchCausedBySdber(2210), coldRestart(2220), workingFacilityOrEqptForcedSwitchedToWorking(2230), workingFacilityOrEqptForcedSwitchedToWorkingRing(2240), workingFacilityOrEqptForcedSwitchedToWorkingSpan(2250), workingFacilityOrEqptForcedSwitchedProtectionUnit(2260), workingFacilityOrEqptForcedSwitchedProtectionUnitRing(2270), workingFacilityOrEqptForcedSwitchedProtectionUnitSpan(2280), workingFacilityOrEqptForcedSwitchedProtectionUnitPath(2290), initializationInitiated(2300), lockoutOfProtection(2310), lockoutOfProtectionRing(2320), lockoutOfProtectionSpan(2330), lockoutOfProtectionPath(2340), lockoutOfWorking(2350), lockoutOfWorkingRing(2360), lockoutOfWorkingSpan(2370), manualSystemReset(2380), manualSynchronizationSwitchToInternalClock(2390), manualSynchronizationSwitchToPrimaryRefernce(2400), manualSynchronizationSwitchToSecondRefernce(2410), manualSynchronizationSwitchToThirdRefernce(2420), manualSynchronizationSwitchToFourthRefernce(2430), manualSynchronizationSwitchToFifthRefernce(2440), manualSynchronizationSwitchToSixthRefernce(2450), manualSwitchOfWorkingFacilityOrEqptToProtectionRing(2460), manualSwitchOfWorkingFacilityOrEqptToProtectionSpan(2470), manualSwitchOfWorkingFacilityOrEqptToProtection(2480), manualSwitchOfWorkingFacilityOrEqptToProtectionUnit(2490), workingFacilityOrEqptManualSwitchToProtectionUnitRing(2500), workingFacilityOrEqptManualSwitchToProtectionUnitSpan(2510), manualSwitchOfWorkingFacilityOrEqptToProtectionPath(2520), powerFailureRestart(2530), ringIsSquelchingTraffic(2540), softwareDownloadInProgress(2550), synchronizationSwitchToInternalClock(2560), synchronizationSwitchToPrimaryRefernce(2570), synchronizationSwitchToSecondRefernce(2580), synchronizationSwitchToThirdRefernce(2590), synchronizationSwitchToFourthRefernce(2600), synchronizationSwitchToFifthRefernce(2610), synchronizationSwitchToSixthRefernce(2620), systemReboot(2630), workingFacilityOrEquipmentSwitchedBackToWorking(2640), workingFacilityOrEquipmentSwitchedToProtectionUnit(2650), warmRestart(2660), lineIsInWaitToRestoreStateSONET(2670), manualSwitchRequestOnFacilityOrEquipment(2680), forceSwitchRequestOnFacilityOrEquipment(2690), lockoutSwitchRequestOnFacilityOrEquipment(2700), rmonHistoriesAndAlarmsReset(2710), rmonThresholdCrossingAlarm(2720), freeMemoryOnCardVeryLow(2830), freeMemoryOnCardAlmostGone(2840) | ||
| Cerent454EntityClass | |||
| This is the TC used to find out to which cerent454EntityClass an alarm belongs to. The first octet of the alarmIndex value is mapped to the following enum. Look at cerent454AlarmIndex for more details. | |||
| TEXTUAL-CONVENTION | |||
| INTEGER | unknownEntity(1), ne(10), ccNe(20), backplane(30), ccBackplane(40), eqpt(50), ccEqpt(60), ocn(70), ccOcn(80), thOcn(90), sdcc(100), ds3(110), ccDs3(120), thDs3(130), stsMon(140), ccStsMon(150), stsTerm(160), ccStsTerm(170), thStsTerm(180), psSts(190), ccPsSts(200), xcSts(210), bits(220), ccBits(230), neSynchref(240), ccNeSynchref(250), extSynchref(260), ccExtSynchref(270), envalrm(280), envctrl(290), javaSpe(300), ringMap(310), squelchTable(320), payloadTable(330), userTable(340), routingTable(350), stsRing(360), ifGrp(370), craft(380), ds1(390), ccDs1(400), thDs1(410), vtTerm(420), ccVtTerm(430), thVtTerm(440), spareSdcc(450), ccSdcc(460), thSdcc(470), ds2(480), ccDs2(490), thDs2(500), ec112(510), ps(520), psVt(530), e100t(540), e1000f(550), etherBridge(560), entNb(570), entDs1(1010), entDs3(1020), ringPort(1180), ringPath(1190), entOc3(1200), entOc12(1210), entOc48(1220), entOc192(1230), entSts1(1240), entSts3c(1250), entSts12c(1260), entSts48c(1270), entSyncn(1280) | ||
| Cerent454AlarmEntry | |||
| SEQUENCE | |||
| Integer32 as cerent454AlarmIndex | |||
| Cerent454EntityClass as cerent454AlarmObjectType | |||
| Integer32 as cerent454AlarmSlotNumber | |||
| Integer32 as cerent454AlarmPortNumber | |||
| Integer32 as cerent454AlarmLineNumber | |||
| Integer32 as cerent454AlarmObjectIndex | |||
| Cerent454AlarmType as cerent454AlarmType | |||
| CerentNotificationClass as cerent454AlarmState | |||
| TimeStamp as cerent454AlarmTimeStamp | |||