| ciscoEntitySensorHistoryMIB |
1.3.6.1.4.1.9.9.768 |
| This MIB module defines objects that describe collections and measurement information for each sensor supporting historical data collection. The sensor measurement either represents a measured value or a SMA (Simple Moving Average) value for a specified interval rate over a period of time. This MIB module defines two tables relating to sensor measured value, including: o ceshCollectionTable - contains data describing a collection of historic data for a sensor. o ceshCollectionIntervalTable - contains zero or more rows containing historic data for a sensor The figure below illustrates the relationship between these two tables. +----------------------------------------------+ | ceshCollectionTable | | +------------------------------------------+ | | | ceshCollectionEntry | | | | entPhysicalIndex = 3 | | | | ceshCollectionIntervalTime = 60 | | | | ceshCollectionIntervals = 60 | | | | ceshCollectionInvalidIntervals = 0 |-----+ | | ceshCollectionMaxIntervals = 60 | | | | | ceshCollectionElapsedTime = 20 | | | | | ceshCollectionAlgorithm = 3 | | | | +------------------------------------------+ | | | +------------------------------------------+ | | | | ceshCollectionEntry | | | | | entPhysicalIndex = 3 | | | | | ceshCollectionIntervalTime = 3660 | | | | | ceshCollectionIntervals = 2 |------------+ | | ceshCollectionInvalidIntervals = 0 | | | | | | ceshCollectionMaxIntervals = 60 | | | | | | ceshCollectionElapsedTime = 20 | | | | | | ceshCollectionAlgorithm = 4 | | | | | +------------------------------------------+ | | | +----------------------------------------------+ | | | | +----------------------------------------------+ | | | ceshCollectionIntervalTable | | | | +------------------------------------------+ | | | | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |<----+ | | | ceshCollectionIntervalTime = 60 | | | | | | ceshCollectionIntervalNumber = 1 | | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | | ceshCollectionIntervalTimeStamp = 1 | | | | | +------------------------------------------+ | | | | .................... <----+ | | skipped 58 entries <----+ | | .................... <----+ | | | | | | +------------------------------------------+ | | | | | ceshCollectionIntervalEntry | | | | | | entPhysicalIndex = 3 |<----+ | | | ceshCollectionIntervalTime = 60 | | | | | ceshCollectionIntervalNumber = 60 | | | | | ceshCollectionIntervalSensorValue = 54 | | | | | ceshCollectionIntervalTimeStamp = 60 | | | | +------------------------------------------+ | | | | | | +------------------------------------------+ | | | | ceshCollectionIntervalEntry | | | | | entPhysicalIndex = 3 |<-----------+ | | ceshCollectionIntervalTime = 3660 | | | | ceshCollectionIntervalNumber = 1 | | | | ceshCollectionIntervalSensorValue = 54 | | | | ceshCollectionIntervalTimeStamp = 60 | | | +------------------------------------------+ | +----------------------------------------------+ If the system samples a sensor every minute for one collection and every hour for another, then the ceshCollectionTable contains two entries describing the two collections. |
| MODULE-IDENTITY |
|
|
|
| ciscoEntitySensorHistoryMIBObjects |
1.3.6.1.4.1.9.9.768.0 |
| OBJECT IDENTIFIER |
|
|
|
| ceshCollectionEntry |
1.3.6.1.4.1.9.9.768.0.1.1 |
| Each entry in the ceshCollectionTable contains collection attributes describing the collection. For each supported sensor, the system creates a row for each prescribed collection. This creation process happens at startup and following the insertion of a FRU containing sensors. The system destroys a row when it destroys the corresponding row in the entPhysicalTable, which can happen as the result of the removal of the FRU containing the sensor. |
| OBJECT-TYPE |
|
|
|
| |
CeshCollectionEntry |
|
|
| ceshCollectionIntervalEntry |
1.3.6.1.4.1.9.9.768.0.2.1 |
| An entry describes the data collected for an interval. The system creates a row in the ceshCollectionIntervalTable after it has sampled a sample for a given collection. The maximum allowable entries for a collection should be less than or equal to the value specified by ceshCollectionMaxIntervals instance. Once number of entries is equal to ceshCollectionMaxIntervals, then the system destroys the lease recent row from the collection before creating a new one. An agent destroys all conceptual entries corresponding to a physical entity upon removal of the physical entity. |
| OBJECT-TYPE |
|
|
|
| |
CeshCollectionIntervalEntry |
|
|
| ciscoEntitySensorHistoryMIBCompliances |
1.3.6.1.4.1.9.9.768.1.1 |
| OBJECT IDENTIFIER |
|
|
|
| ciscoEntitySensorHistoryCompliance |
1.3.6.1.4.1.9.9.768.1.1.1 |
| Describes the requirements for conformance to the Entity Sensor History Collection MIB module. |
| MODULE-COMPLIANCE |
|
|
|
| ciscoEntitySensorHistoryMIBGroups |
1.3.6.1.4.1.9.9.768.1.2 |
| OBJECT IDENTIFIER |
|
|
|
| SensorHistoryCollectionAlgorithm |
|
| This textual convention denotes an enumerated integer-value that describing the method used to collect historic data for a sensor. 'other' - The implementation of the MIB module using this textual convention does not recognize the historic data collection algorithm. 'unknown' - The system is not able to ascertain the historic data collection algorithm. 'measured' - A raw value. 'simpleAverage' - The system collects a simple moving average of the values sampled from the sensor. |
| TEXTUAL-CONVENTION |
|
|
|
| |
INTEGER |
other(1), unknown(2), measured(3), algoSMA(4) |
|
| CeshCollectionEntry |
|
| SEQUENCE |
|
|
|
| |
Unsigned32 as ceshCollectionIntervalTime |
|
|
| |
Gauge32 as ceshCollectionIntervals |
|
|
| |
Gauge32 as ceshCollectionInvalidIntervals |
|
|
| |
Unsigned32 as ceshCollectionMaxIntervals |
|
|
| |
Gauge32 as ceshCollectionElapsedTime |
|
|
| |
SensorHistoryCollectionAlgorithm as ceshCollectionAlgorithm |
|
|
| CeshCollectionIntervalEntry |
|
| SEQUENCE |
|
|
|
| |
Unsigned32 as ceshCollectionIntervalNumber |
|
|
| |
EntitySensorValue as ceshCollectionIntervalSensorValue |
|
|
| |
TimeStamp as ceshCollectionIntervalTimeStamp |
|
|