CISCO-MGX82XX-SONET-MIB

File: CISCO-MGX82XX-SONET-MIB.mib (144604 bytes)

Imported modules

RFC1155-SMI BASIS-MIB RFC-1212
RFC1213-MIB

Imported symbols

Counter Gauge cwsonetObjects
OBJECT-TYPE DisplayString

Defined Objects

sonetConfig 1.3.6.1.4.1.351.110.4.6.1.1
OBJECT IDENTIFIER    

sonetConfigTable 1.3.6.1.4.1.351.110.4.6.1.1.1
The SONET Configuration table. There is one row for each SONET port in the BASIS system. The table size (number of rows) is given by the value of sonetLineNumOfValidEntries.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetConfigEntry

sonetConfigEntry 1.3.6.1.4.1.351.110.4.6.1.1.1.1
An entry in the SONET Configuration table.
OBJECT-TYPE    
  SonetConfigEntry  

sonetLineNum 1.3.6.1.4.1.351.110.4.6.1.1.1.1.1
This object is the identifier of a SONET Interface on a managed device. For MGX8850(For example PXM1 Module): OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid number For Other: sonetLineNum = 1 is the ONLY valid number
OBJECT-TYPE    
  INTEGER 1..4  

sonetLineType 1.3.6.1.4.1.351.110.4.6.1.1.1.1.2
This variable indicates the cell framing. Defaults to Sts-3c
OBJECT-TYPE    
  INTEGER sonetSts3c(1), sonetStm1(2), sonetSts12c(3), sonetStm4(4), sonetSts48c(5), sonetStm16(6), sonetSts192c(7), sonetStm64(8), sonetSts3(9)  

sonetLineLoopbackCommand 1.3.6.1.4.1.351.110.4.6.1.1.1.1.3
This variable represents the loopback configuration of the SONET interface. The values mean: sonetNoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as it's value. sonetRemoteLineLoop Near End loops back Remote data sonetLocalLineLoop Near End loops back Local data.
OBJECT-TYPE    
  INTEGER sonetNoLoop(1), sonetRemoteLineLoop(2), sonetLocalLineLoop(3)  

sonetHCSmasking 1.3.6.1.4.1.351.110.4.6.1.1.1.1.4
HCS masking. Defaults to enable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sonetPayloadScrambling 1.3.6.1.4.1.351.110.4.6.1.1.1.1.5
STS3c or STM-1 payload scrambling. Defaults to enable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sonetFrameScrambling 1.3.6.1.4.1.351.110.4.6.1.1.1.1.6
STS3c or STM-1 frame scrambling. Defaults to enable.
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

sonetLineEnable 1.3.6.1.4.1.351.110.4.6.1.1.1.1.7
This variable indicates if the line is enabled or not defaults to disable
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sonetLineXmtClkSrc 1.3.6.1.4.1.351.110.4.6.1.1.1.1.8
This represents the type of transmit clock source. backplaneClk: clock source is from the controller card, transmitted via the backplane to the service module. recoverClk: clock is recovered from the received signal. localClk: clock is from a local oscillator on the card. Default is backplaneClk.
OBJECT-TYPE    
  INTEGER backplaneClk(1), recoverClk(2), localClk(3)  

sonetRDIVType 1.3.6.1.4.1.351.110.4.6.1.1.1.1.9
This variable represents the type of RDI-V sent by this NE to remote NE. onebit: use 1 bit RDI-V. Compatible with older equipment. threebit: use 3 bit, enhanced RDI-V. Defaults to onebit.
OBJECT-TYPE    
  INTEGER onebit(1), threebit(3)  

sonetRDIPType 1.3.6.1.4.1.351.110.4.6.1.1.1.1.10
This variable represents the type of RDI-P sent by this NE to remote NE. onebit: use 1 bit RDI-P. Compatible with older equipment. threebit: use 3 bit, enhanced RDI-P. Defaults to onebit.
OBJECT-TYPE    
  INTEGER onebit(1), threebit(3)  

sonetTributaryType 1.3.6.1.4.1.351.110.4.6.1.1.1.1.11
Type of tributary carried within the Sonet/Sdh signal. vt15vc11: carries T1 signals (VT15 or VC11) vt2vc12: carries E1 signals (VT2 or VC12) Default is vt15vc11 for Sonet interfaces and vt2vc12 for SDH interfaces.
OBJECT-TYPE    
  INTEGER vt15vc11(1), vt2vc12(2)  

sonetTributaryMappingType 1.3.6.1.4.1.351.110.4.6.1.1.1.1.12
Type of VT/VC mapping. asynchronous: In this mode, the channel structure of the DS1/E1 is neither visible nor preserved. byteSynchronous: In this mode, the DS0 channels inside the VC/VT can be found and extracted. Default is asynchronous.
OBJECT-TYPE    
  INTEGER asynchronous(1), byteSynchronous(2)  

sonetTributaryFramingFormat 1.3.6.1.4.1.351.110.4.6.1.1.1.1.13
Type of vt framing format. Is applicable only in byte-sync mapping mode for T1 tributaries. notApplicable: if VT mapping is not byte-sync. sf: superframe format. esf: extended superframe format. Default is esf if sonetTributaryMappingType is set to byteSynchronous, else the default is notApplicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), sf(2), esf(3)  

sonetSignallingTransportMode 1.3.6.1.4.1.351.110.4.6.1.1.1.1.14
The mode used to transport DS0 signalling information for T1 byte-sync mapping. notApplicable: if byte-sync mapping is not used. signallingTransferMode: the robbed bit signalling is transferred into the S bits of the VT header and framing bit is discarded. clearMode: only the framing bit is transferred to VT header. The signalling bits are left intact in the VT payload. Default is signallingTransferMode if sonetTributaryMappingType is set to byteSynchronous, else the default is notApplicable.
OBJECT-TYPE    
  INTEGER notApplicable(1), signallingTransferMode(2), clearMode(3)  

sonetTributaryGroupingType 1.3.6.1.4.1.351.110.4.6.1.1.1.1.15
This variable indicates the method used to group VCs into an STM-1 signal. Applicable only to SDH. notApplicable: for sonet interfaces. au3Grouping: STM-1 <- AU-3 <- TUG-2 <- TU-12 <- VC12 or STM-1 <- AU-3 <- TUG-2 <- TU-11 <- VC11. au4Grouping: STM-1 <- AU-4 <- TUG-3 <- TUG-2 <- TU-12 <- VC12 or STM-1 <- AU-4 <- TUG-3 <- TUG-2 <- TU-11 <- VC11. Defaults to au3Grouping for SDH interfaces and notApplicable for Sonet interfaces.
OBJECT-TYPE    
  INTEGER notApplicable(1), au3Grouping(2), au4Grouping(3)  

sonetConfigNumOfValidEntries 1.3.6.1.4.1.351.110.4.6.1.1.2
The number of SONET configuration entries (regardless of their current configuration) in the sonetConfigTable.
OBJECT-TYPE    
  INTEGER  

cwsonetMedium 1.3.6.1.4.1.351.110.4.6.1.2
OBJECT IDENTIFIER    

cwSonetMediumTable 1.3.6.1.4.1.351.110.4.6.1.2.1
Sonet medium table parameters
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetMediumEntry

cwSonetMediumEntry 1.3.6.1.4.1.351.110.4.6.1.2.1.1
An entry in the SONET/SDH Medium table.
OBJECT-TYPE    
  CwSonetMediumEntry  

cwSonetMediumType 1.3.6.1.4.1.351.110.4.6.1.2.1.1.1
This variable identifies whether a SONET or a SDH signal is used across this interface.
OBJECT-TYPE    
  INTEGER sonet(1), sdh(2)  

cwSonetMediumTimeElapsed 1.3.6.1.4.1.351.110.4.6.1.2.1.1.2
The number of seconds, including partial seconds, that have elapsed since the beginning of the mandatory error-measurement period.
OBJECT-TYPE    
  INTEGER 1..900  

cwSonetMediumValidIntervals 1.3.6.1.4.1.351.110.4.6.1.2.1.1.3
The number of previous intervals for which valid data has been stored. A SONET device must support at least n intervals. The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value of this object will be n unless the device was brought online within the last (nx15) minutes, in which case the value will be the number of complete 15 minute intervals the device has been online.
OBJECT-TYPE    
  INTEGER 0..96  

cwSonetMediumLineCoding 1.3.6.1.4.1.351.110.4.6.1.2.1.1.4
This variable describes the line coding for this interface. The B3ZS and CMI are used for electrical SONET/SDH signals (STS-1 and STS-3). The Non-Return to Zero (NRZ) and the Return to Zero are used for optical SONET/SDH signals.
OBJECT-TYPE    
  INTEGER sonetMediumOther(1), sonetMediumB3ZS(2), sonetMediumCMI(3), sonetMediumNRZ(4), sonetMediumRZ(5)  

cwSonetMediumLineType 1.3.6.1.4.1.351.110.4.6.1.2.1.1.5
This variable describes the line type for this interface. The line types are Short and Long Range Single Mode fiber or Multi-Mode fiber interfaces, and coax and UTP for electrical interfaces. The value sonetOther should be used when the Line Type is not one of the listed values.
OBJECT-TYPE    
  INTEGER sonetOther(1), sonetShortSingleMode(2), sonetLongSingleMode(3), sonetMultiMode(4), sonetCoax(5), sonetUTP(6)  

cwSonetMediumCircuitIdentifier 1.3.6.1.4.1.351.110.4.6.1.2.1.1.6
This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting.
OBJECT-TYPE    
  DisplayString SIZE(0..255)  

cwsonetSection 1.3.6.1.4.1.351.110.4.6.1.3
OBJECT IDENTIFIER    

cwSonetSectionCurrentTable 1.3.6.1.4.1.351.110.4.6.1.3.1
The SONET/SDH Section Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetSectionCurrentEntry

cwSonetSectionCurrentEntry 1.3.6.1.4.1.351.110.4.6.1.3.1.1
An entry in the SONET/SDH Section Current table.
OBJECT-TYPE    
  CwSonetSectionCurrentEntry  

cwSonetSectionCurrentLineNum 1.3.6.1.4.1.351.110.4.6.1.3.1.1.1
line number. There are Max 1 line Num
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetSectionCurrentStatus 1.3.6.1.4.1.351.110.4.6.1.3.1.1.2
This variable indicates the status of the sonet section layer. The cwSonetSectionCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetSectionNoDefect should be set if and only if no other flag is set. The various bit positions are: bit 1 = sonetSectionNoDefect bit 2 = sonetSectionLOS bit 3 = sonetSectionLOF
OBJECT-TYPE    
  INTEGER 1..6  

cwSonetSectionCurrentValidFlag 1.3.6.1.4.1.351.110.4.6.1.3.1.1.3
Indicates if the current 15min bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetSectionCurrent15minTimeElapsed 1.3.6.1.4.1.351.110.4.6.1.3.1.1.4
The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period.
OBJECT-TYPE    
  INTEGER 1..900  

cwSonetSectionCurrentESs 1.3.6.1.4.1.351.110.4.6.1.3.1.1.5
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in the current 15 minute interval.
OBJECT-TYPE    
  Counter  

cwSonetSectionCurrentSESs 1.3.6.1.4.1.351.110.4.6.1.3.1.1.6
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in the current 15 minute interval.
OBJECT-TYPE    
  Counter  

cwSonetSectionCurrentSEFSs 1.3.6.1.4.1.351.110.4.6.1.3.1.1.7
The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in the current 15 minute interval.
OBJECT-TYPE    
  Counter  

cwSonetSectionCurrentCVs 1.3.6.1.4.1.351.110.4.6.1.3.1.1.8
The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in the current 15 minute interval.
OBJECT-TYPE    
  Counter  

cwSonetSectionCurrentClrButton 1.3.6.1.4.1.351.110.4.6.1.3.1.1.9
Clears all the Section's Current15min counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

sonetSectionCurrentDayTable 1.3.6.1.4.1.351.110.4.6.1.3.2
The SONET/SDH Section CurrentDay table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetSectionCurrentDayEntry

sonetSectionCurrentDayEntry 1.3.6.1.4.1.351.110.4.6.1.3.2.1
An entry in the SONET/SDH Section CurrentDay table.
OBJECT-TYPE    
  SonetSectionCurrentDayEntry  

sonetSectionCurrentDayLineNum 1.3.6.1.4.1.351.110.4.6.1.3.2.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetSectionCurrentDayValidFlag 1.3.6.1.4.1.351.110.4.6.1.3.2.1.2
Indicates if the current day bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

sonetSectionCurrentDayESs 1.3.6.1.4.1.351.110.4.6.1.3.2.1.3
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in the CurrentDay one day interval.
OBJECT-TYPE    
  Counter  

sonetSectionCurrentDaySESs 1.3.6.1.4.1.351.110.4.6.1.3.2.1.4
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in the CurrentDay minute interval.
OBJECT-TYPE    
  Counter  

sonetSectionCurrentDaySEFSs 1.3.6.1.4.1.351.110.4.6.1.3.2.1.5
The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in the CurrentDay one day interval.
OBJECT-TYPE    
  Counter  

sonetSectionCurrentDayCVs 1.3.6.1.4.1.351.110.4.6.1.3.2.1.6
The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in the CurrentDay one day interval.
OBJECT-TYPE    
  Counter  

sonetSectionCurrentDayClrButton 1.3.6.1.4.1.351.110.4.6.1.3.2.1.7
Clears all the Section's Current Day counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

cwSonetSectionIntervalTable 1.3.6.1.4.1.351.110.4.6.1.3.3
The SONET/SDH Section Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetSectionIntervalEntry

cwSonetSectionIntervalEntry 1.3.6.1.4.1.351.110.4.6.1.3.3.1
An entry in the SONET/SDH Section Interval table.
OBJECT-TYPE    
  CwSonetSectionIntervalEntry  

cwSonetSectionIntervalLineNum 1.3.6.1.4.1.351.110.4.6.1.3.3.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetSectionIntervalNumber 1.3.6.1.4.1.351.110.4.6.1.3.3.1.2
A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
OBJECT-TYPE    
  INTEGER 1..96  

cwSonetSectionIntervalValidFlag 1.3.6.1.4.1.351.110.4.6.1.3.3.1.3
Indicates if the bucket specified by the interval is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetSectionIntervalESs 1.3.6.1.4.1.351.110.4.6.1.3.3.1.4
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Counter  

cwSonetSectionIntervalSESs 1.3.6.1.4.1.351.110.4.6.1.3.3.1.5
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Counter  

cwSonetSectionIntervalSEFss 1.3.6.1.4.1.351.110.4.6.1.3.3.1.6
The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Counter  

cwSonetSectionIntervalCVs 1.3.6.1.4.1.351.110.4.6.1.3.3.1.7
The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Counter  

sonetSectionAlarmTable 1.3.6.1.4.1.351.110.4.6.1.3.4
The SONET/SDH Section Alarm table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetSectionAlarmEntry

sonetSectionAlarmEntry 1.3.6.1.4.1.351.110.4.6.1.3.4.1
An entry in the SONET/SDH Section Alarm table.
OBJECT-TYPE    
  SonetSectionAlarmEntry  

sectionAlarmLineNum 1.3.6.1.4.1.351.110.4.6.1.3.4.1.1
line number. BNM has 1 line
OBJECT-TYPE    
  INTEGER 1..1  

sonetSectionStatisticalAlarmSeverity 1.3.6.1.4.1.351.110.4.6.1.3.4.1.2
When any statistical threshold is exceeded.
OBJECT-TYPE    
  INTEGER minor(1), major(2)  

sonetSectionCurrent15minESsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.3
The default is set to 20.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionCurrentDayESsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.4
The default is set to 200.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionCurrent15minSESsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.5
The default is set to 3.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionCurrentDaySESsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.6
The default is set to 7.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionCurrent15minSEFSsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.7
The default is set to 3.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionCurrentDaySEFSsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.8
The default is set to 7.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionCurrent15minCVsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.9
The default is set to 25.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionCurrentDayCVsThreshold 1.3.6.1.4.1.351.110.4.6.1.3.4.1.10
The default is set to 250.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetSectionTraceSelection 1.3.6.1.4.1.351.110.4.6.1.3.4.1.11
Sonet Section Trace Selection.
OBJECT-TYPE    
  INTEGER none(1), sixtyFourBytes(2), sixtyFourBytesCrlf(3), sixteenBytes(4), sixteenBytesCrc7(5), sixteenBytesMsb1(6)  

sonetSectionTraceToTransmit 1.3.6.1.4.1.351.110.4.6.1.3.4.1.12
Sonet Section Trace To Transmit. 16-64 bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string.
OBJECT-TYPE    
  OCTET STRING SIZE(0..64)  

sonetSectionTraceToExpect 1.3.6.1.4.1.351.110.4.6.1.3.4.1.13
Sonet Section Trace To Expect. 16-64 bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string.
OBJECT-TYPE    
  OCTET STRING SIZE(0..64)  

sonetSectionTraceReceived 1.3.6.1.4.1.351.110.4.6.1.3.4.1.14
Sonet Section Trace Received. 16-64 bytes String. The write option is for debugging only.
OBJECT-TYPE    
  OCTET STRING SIZE(0..64)  

sonetSectionStatAlarmStatus 1.3.6.1.4.1.351.110.4.6.1.3.4.1.15
This variable indicates the status of the interface. The sonetSectionStatAlarmStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineStatAlarmNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetSectionStatAlarmNoDefect 2 sonetSectionCurrent15minESs 3 sonetSectionCurrent15minSESs 4 sonetSectionCurrent15minSEFSs 5 sonetSectionCurrent15minCVs 6 sonetSectionCurrentDayESs 7 sonetSectionCurrentDaySESs 8 sonetSectionCurrentDaySEFSs 9 sonetSectionCurrentDayCVs
OBJECT-TYPE    
  INTEGER 1..'1FF'h  

sonetSectionCounterTable 1.3.6.1.4.1.351.110.4.6.1.3.5
The SONET/SDH Section Counter table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetSectionCounterEntry

sonetSectionCounterEntry 1.3.6.1.4.1.351.110.4.6.1.3.5.1
An entry in the SONET/SDH Section table.
OBJECT-TYPE    
  SonetSectionCounterEntry  

sectionCounterLineNum 1.3.6.1.4.1.351.110.4.6.1.3.5.1.1
line number. There are Max 1 line on the BNM
OBJECT-TYPE    
  INTEGER 1..1  

sonetSectionCounterLOSs 1.3.6.1.4.1.351.110.4.6.1.3.5.1.2
The counter associated with the number of LOSs encountered by a SONET/SDH.
OBJECT-TYPE    
  Gauge  

sonetSectionCounterLOFs 1.3.6.1.4.1.351.110.4.6.1.3.5.1.3
The counter associated with the number of LOFs encountered by a SONET/SDH Section.
OBJECT-TYPE    
  Gauge  

sonetSectionCounterClrButton 1.3.6.1.4.1.351.110.4.6.1.3.5.1.4
Clears all the Section's counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

cwsonetLine 1.3.6.1.4.1.351.110.4.6.1.4
OBJECT IDENTIFIER    

cwSonetLineCurrentTable 1.3.6.1.4.1.351.110.4.6.1.4.1
The SONET/SDH Line Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetLineCurrentEntry

cwSonetLineCurrentEntry 1.3.6.1.4.1.351.110.4.6.1.4.1.1
An entry in the SONET/SDH Line Current table.
OBJECT-TYPE    
  CwSonetLineCurrentEntry  

cwSonetLineCurrentLineNum 1.3.6.1.4.1.351.110.4.6.1.4.1.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetLineCurrentStatus 1.3.6.1.4.1.351.110.4.6.1.4.1.1.2
This variable indicates the status of the sonet line layer. The cwSonetLineCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit positions are: bit 1 = sonetLineNoDefect bit 2 = sonetLineRcvAIS bit 3 = sonetLineRcvRDI bit 4 = sonetLineXmtAis bit 5 = sonetLineXmtRdi
OBJECT-TYPE    
  INTEGER 1..30  

cwSonetLineCurrentValidFlag 1.3.6.1.4.1.351.110.4.6.1.4.1.1.3
Indicates if the current 15min bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetLineCurrent15minTimeElapsed 1.3.6.1.4.1.351.110.4.6.1.4.1.1.4
The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period.
OBJECT-TYPE    
  INTEGER 1..900  

cwSonetLineCurrentESs 1.3.6.1.4.1.351.110.4.6.1.4.1.1.5
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetLineCurrentSESs 1.3.6.1.4.1.351.110.4.6.1.4.1.1.6
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetLineCurrentCVs 1.3.6.1.4.1.351.110.4.6.1.4.1.1.7
The counter associated with the number of Coding Violations encountered by a SONET/SDH Line in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetLineCurrentUASs 1.3.6.1.4.1.351.110.4.6.1.4.1.1.8
The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetLineCurrentClrButton 1.3.6.1.4.1.351.110.4.6.1.4.1.1.9
Clears all the SONET Line's Current15min counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

sonetLineCurrentDayTable 1.3.6.1.4.1.351.110.4.6.1.4.2
The SONET/SDH Line Current Day table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetLineCurrentDayEntry

sonetLineCurrentDayEntry 1.3.6.1.4.1.351.110.4.6.1.4.2.1
An entry in the SONET/SDH Line Current Day table.
OBJECT-TYPE    
  SonetLineCurrentDayEntry  

lineCurrentDayLineNum 1.3.6.1.4.1.351.110.4.6.1.4.2.1.1
line number. BNM has 1 line
OBJECT-TYPE    
  INTEGER 1..1  

sonetLineCurrentDayValidFlag 1.3.6.1.4.1.351.110.4.6.1.4.2.1.2
Indicates if the current day bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

sonetLineCurrentDayESs 1.3.6.1.4.1.351.110.4.6.1.4.2.1.3
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetLineCurrentDaySESs 1.3.6.1.4.1.351.110.4.6.1.4.2.1.4
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetLineCurrentDayCVs 1.3.6.1.4.1.351.110.4.6.1.4.2.1.5
The counter associated with the number of Coding Violations (BIP-8*N for STS-N) encountered by a SONET/SDH Line in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetLineCurrentDayFCs 1.3.6.1.4.1.351.110.4.6.1.4.2.1.6
Number of times that line was in AIS alarm in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetLineCurrentDayUASs 1.3.6.1.4.1.351.110.4.6.1.4.2.1.7
The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetLineCurrentDayClrButton 1.3.6.1.4.1.351.110.4.6.1.4.2.1.8
Clears all the SONET Line's CurrentDay counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

cwSonetLineIntervalTable 1.3.6.1.4.1.351.110.4.6.1.4.3
The SONET/SDH Line Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetLineIntervalEntry

cwSonetLineIntervalEntry 1.3.6.1.4.1.351.110.4.6.1.4.3.1
An entry in the SONET/SDH Line Interval table.
OBJECT-TYPE    
  CwSonetLineIntervalEntry  

cwSonetLineIntervalLineNum 1.3.6.1.4.1.351.110.4.6.1.4.3.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetLineIntervalNumber 1.3.6.1.4.1.351.110.4.6.1.4.3.1.2
A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
OBJECT-TYPE    
  INTEGER 1..96  

cwSonetLineIntervalValidFlag 1.3.6.1.4.1.351.110.4.6.1.4.3.1.3
Indicates if the bucket specified by the interval is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetLineIntervalESs 1.3.6.1.4.1.351.110.4.6.1.4.3.1.4
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetLineIntervalSESs 1.3.6.1.4.1.351.110.4.6.1.4.3.1.5
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetLineIntervalCVs 1.3.6.1.4.1.351.110.4.6.1.4.3.1.6
The counter associated with the number of Coding Violations (BIP-8*N) encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetLineIntervalFCs 1.3.6.1.4.1.351.110.4.6.1.4.3.1.7
Number of times that line was in AIS alarm in the particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetLineIntervalUASs 1.3.6.1.4.1.351.110.4.6.1.4.3.1.8
The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineCurrentTable 1.3.6.1.4.1.351.110.4.6.1.4.4
The SONET/SDH Far End Line Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetFarEndLineCurrentEntry

cwSonetFarEndLineCurrentEntry 1.3.6.1.4.1.351.110.4.6.1.4.4.1
An entry in the SONET/SDH Far End Line Current table.
OBJECT-TYPE    
  CwSonetFarEndLineCurrentEntry  

cwSonetFELineCurrentLineNum 1.3.6.1.4.1.351.110.4.6.1.4.4.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetFarEndLineCurrentValidFlag 1.3.6.1.4.1.351.110.4.6.1.4.4.1.2
Indicates if the Far End current 15min bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetFarEndLineCurrentTimeElapsed 1.3.6.1.4.1.351.110.4.6.1.4.4.1.3
The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period.
OBJECT-TYPE    
  INTEGER 1..900  

cwSonetFarEndLineCurrentESs 1.3.6.1.4.1.351.110.4.6.1.4.4.1.4
The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineCurrentSESs 1.3.6.1.4.1.351.110.4.6.1.4.4.1.5
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineCurrentCVs 1.3.6.1.4.1.351.110.4.6.1.4.4.1.6
The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Medium/Section/Line interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineCurrentFCs 1.3.6.1.4.1.351.110.4.6.1.4.4.1.7
The counter associated with the number of RFI failures occurred in the current 15 min.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineCurrentUASs 1.3.6.1.4.1.351.110.4.6.1.4.4.1.8
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineCurrentClrButton 1.3.6.1.4.1.351.110.4.6.1.4.4.1.9
Clears all the SONET Far End Line's Current 15min counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

sonetFarEndLineCurrentDayTable 1.3.6.1.4.1.351.110.4.6.1.4.5
The SONET/SDH Far End Line CurrentDay table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetFarEndLineCurrentDayEntry

sonetFarEndLineCurrentDayEntry 1.3.6.1.4.1.351.110.4.6.1.4.5.1
An entry in the SONET/SDH Far End Line CurrentDay table.
OBJECT-TYPE    
  SonetFarEndLineCurrentDayEntry  

sonetFELineCurrentDayLineNum 1.3.6.1.4.1.351.110.4.6.1.4.5.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetFarEndLineCurrentDayValidFlag 1.3.6.1.4.1.351.110.4.6.1.4.5.1.2
Indicates if the Far End current day bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

sonetFarEndLineCurrentDayESs 1.3.6.1.4.1.351.110.4.6.1.4.5.1.3
The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndLineCurrentDaySESs 1.3.6.1.4.1.351.110.4.6.1.4.5.1.4
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndLineCurrentDayCVs 1.3.6.1.4.1.351.110.4.6.1.4.5.1.5
The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Medium/Section/Line interface in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndLineCurrentDayFCs 1.3.6.1.4.1.351.110.4.6.1.4.5.1.6
The counter associated with the number of RFI failures occurred in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndLineCurrentDayUASs 1.3.6.1.4.1.351.110.4.6.1.4.5.1.7
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Medium/Section/Line interface in the current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndLineCurrentDayClrButton 1.3.6.1.4.1.351.110.4.6.1.4.5.1.8
Clears all the SONET Far End Line's Current Day counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

cwSonetFarEndLineIntervalTable 1.3.6.1.4.1.351.110.4.6.1.4.6
The SONET/SDH Far End Line Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetFarEndLineIntervalEntry

cwSonetFarEndLineIntervalEntry 1.3.6.1.4.1.351.110.4.6.1.4.6.1
An entry in the SONET/SDH Far End Line Interval table.
OBJECT-TYPE    
  CwSonetFarEndLineIntervalEntry  

cwSonetFELineIntervalLineNum 1.3.6.1.4.1.351.110.4.6.1.4.6.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetFarEndLineIntervalNumber 1.3.6.1.4.1.351.110.4.6.1.4.6.1.2
A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
OBJECT-TYPE    
  INTEGER 1..96  

cwSonetFarEndLineIntervalValidFlag 1.3.6.1.4.1.351.110.4.6.1.4.6.1.3
Indicates if the bucket specified by the interval is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetFarEndLineIntervalESs 1.3.6.1.4.1.351.110.4.6.1.4.6.1.4
The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineIntervalSESs 1.3.6.1.4.1.351.110.4.6.1.4.6.1.5
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineIntervalCVs 1.3.6.1.4.1.351.110.4.6.1.4.6.1.6
The counter associated with the number of Far End Coding Violations reported via the far end block error count encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineIntervalFCs 1.3.6.1.4.1.351.110.4.6.1.4.6.1.7
The counter associated with the number of RFI failures in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndLineIntervalUASs 1.3.6.1.4.1.351.110.4.6.1.4.6.1.8
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Line interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

sonetLineAlarmTable 1.3.6.1.4.1.351.110.4.6.1.4.7
The SONET/SDH Line Alarm table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetLineAlarmEntry

sonetLineAlarmEntry 1.3.6.1.4.1.351.110.4.6.1.4.7.1
An entry in the SONET/SDH Line Alarm table.
OBJECT-TYPE    
  SonetLineAlarmEntry  

sonetLineAlarmLineNum 1.3.6.1.4.1.351.110.4.6.1.4.7.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetLineStatisticalAlarmSeverity 1.3.6.1.4.1.351.110.4.6.1.4.7.1.2
When any statistical threshold is exceeded.
OBJECT-TYPE    
  INTEGER minor(1), major(2)  

sonetLineCurrent15minESsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.3
The default is set to 20. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineCurrentDayESsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.4
The default is set to 200. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineCurrent15minSESsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.5
The default is set to 3. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineCurrentDaySESsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.6
The default is set to 7. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineCurrent15minCVsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.7
The default is set to 25. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineCurrentDayCVsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.8
The default is set to 250. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineCurrent15minUASsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.9
The default is set to 10. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineCurrentDayUASsThreshold 1.3.6.1.4.1.351.110.4.6.1.4.7.1.10
The default is set to 10. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetLineStatAlarmStatus 1.3.6.1.4.1.351.110.4.6.1.4.7.1.11
This variable indicates the status of the interface. The sonetLineStatAlarmStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineStatAlarmNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetLineStatAlarmNoDefect 2 sonetLineCurrent15minESs 3 sonetLineCurrent15minSESs 4 sonetLineCurrent15minCVs 5 sonetLineCurrent15minUASs 6 sonetFarEndLineCurrent15minESs 7 sonetFarEndLineCurrent15minSESs 8 sonetFarEndLineCurrent15minCVs 9 sonetFarEndLineCurrent15minUASs 10 sonetLineCurrentDayESs 11 sonetLineCurrentDaySESs 12 sonetLineCurrentDayCVs 13 sonetLineCurrentDayUASs 14 sonetFarEndLineCurrentDayESs 15 sonetFarEndLineCurrentDaySESs 16 sonetFarEndLineCurrentDayCVs 17 sonetFarEndLineCurrentDayUASs
OBJECT-TYPE    
  INTEGER 1..'1FFFF'h  

sonetLineCounterTable 1.3.6.1.4.1.351.110.4.6.1.4.8
The SONET/SDH Line Counter table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetLineCounterEntry

sonetLineCounterEntry 1.3.6.1.4.1.351.110.4.6.1.4.8.1
An entry in the SONET/SDH Line table.
OBJECT-TYPE    
  SonetLineCounterEntry  

sonetLineCounterLineNum 1.3.6.1.4.1.351.110.4.6.1.4.8.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetLineCounterAISs 1.3.6.1.4.1.351.110.4.6.1.4.8.1.2
The counter associated with the number of AISs encountered by a SONET/SDH.
OBJECT-TYPE    
  Gauge  

sonetLineCounterRFIs 1.3.6.1.4.1.351.110.4.6.1.4.8.1.3
The counter associated with the number of RFIs encountered by a SONET/SDH Line.
OBJECT-TYPE    
  Gauge  

sonetLineCounterClrButton 1.3.6.1.4.1.351.110.4.6.1.4.8.1.4
Clears all the Line's counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

cwsonetPath 1.3.6.1.4.1.351.110.4.6.1.5
OBJECT IDENTIFIER    

cwSonetPathCurrentTable 1.3.6.1.4.1.351.110.4.6.1.5.1
The SONET/SDH Path Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetPathCurrentEntry

cwSonetPathCurrentEntry 1.3.6.1.4.1.351.110.4.6.1.5.1.1
An entry in the SONET/SDH Path Current table.
OBJECT-TYPE    
  CwSonetPathCurrentEntry  

cwSonetPathCurrentLineNum 1.3.6.1.4.1.351.110.4.6.1.5.1.1.1
line number. BNM has 1 line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetPathCurrentStatus 1.3.6.1.4.1.351.110.4.6.1.5.1.1.2
This variable indicates the status of the sonet path layer. The cwSonetPathCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetPathNoDefect should be set if and only if no other flag is set. The various bit positions are: bit 1 = sonetPathNoDefect bit 2 = sonetPathRcvLOP bit 3 = sonetPathRcvAIS bit 4 = sonetPathRcvRDI bit 5 = sonetPathUnequipted bit 6 = sonetPathSignalLabelMismatch bit 7 = sonetPathTraceFailure bit 8 = sonetPathXmtAis bit 9 = sonetPathXmtRdi bit 10 = sonetPathRcvLOCD
OBJECT-TYPE    
  INTEGER 1..1022  

cwSonetPathCurrentValidFlag 1.3.6.1.4.1.351.110.4.6.1.5.1.1.3
Indicates if the current 15min bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetPathCurrentTimeElapsed 1.3.6.1.4.1.351.110.4.6.1.5.1.1.4
The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period.
OBJECT-TYPE    
  INTEGER 1..900  

cwSonetPathCurrentESs 1.3.6.1.4.1.351.110.4.6.1.5.1.1.5
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetPathCurrentSESs 1.3.6.1.4.1.351.110.4.6.1.5.1.1.6
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetPathCurrentCVs 1.3.6.1.4.1.351.110.4.6.1.5.1.1.7
The counter associated with the number of Coding Violations (BIP-8) encountered by a SONET/SDH Path in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetPathCurrentFCs 1.3.6.1.4.1.351.110.4.6.1.5.1.1.8
Number of times that Path was in AIS or LOP alarm in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetPathCurrentUASs 1.3.6.1.4.1.351.110.4.6.1.5.1.1.9
The counter associated with the number of Unavailable Seconds encountered by a Path in the current 15 minute, interval.
OBJECT-TYPE    
  Gauge  

cwSonetPathCurrentClrButton 1.3.6.1.4.1.351.110.4.6.1.5.1.1.10
Clears all the SONET Path's Current counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

sonetPathCurrentDayTable 1.3.6.1.4.1.351.110.4.6.1.5.2
The SONET/SDH Path CurrentDay table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetPathCurrentDayEntry

sonetPathCurrentDayEntry 1.3.6.1.4.1.351.110.4.6.1.5.2.1
An entry in the SONET/SDH Path CurrentDay table.
OBJECT-TYPE    
  SonetPathCurrentDayEntry  

sonetPathCurrentDayLineNum 1.3.6.1.4.1.351.110.4.6.1.5.2.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetPathCurrentDayValidFlag 1.3.6.1.4.1.351.110.4.6.1.5.2.1.2
Indicates if the current day bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

sonetPathCurrentDayESs 1.3.6.1.4.1.351.110.4.6.1.5.2.1.3
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetPathCurrentDaySESs 1.3.6.1.4.1.351.110.4.6.1.5.2.1.4
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetPathCurrentDayCVs 1.3.6.1.4.1.351.110.4.6.1.5.2.1.5
The counter associated with the number of Coding Violations (BIP-8) encountered by a SONET/SDH Path in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetPathCurrentDayFCs 1.3.6.1.4.1.351.110.4.6.1.5.2.1.6
Number of times that Path was in AIS or LOP alarm in the Current interval.
OBJECT-TYPE    
  Gauge  

sonetPathCurrentDayUASs 1.3.6.1.4.1.351.110.4.6.1.5.2.1.7
The counter associated with the number of Unavailable Seconds encountered by a Path in the Current day, interval.
OBJECT-TYPE    
  Gauge  

sonetPathCurrentDayClrButton 1.3.6.1.4.1.351.110.4.6.1.5.2.1.8
Clears all the SONET Path's CurrentDay counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

cwSonetPathIntervalTable 1.3.6.1.4.1.351.110.4.6.1.5.3
The SONET/SDH Path Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetPathIntervalEntry

cwSonetPathIntervalEntry 1.3.6.1.4.1.351.110.4.6.1.5.3.1
An entry in the SONET/SDH Path Interval table.
OBJECT-TYPE    
  CwSonetPathIntervalEntry  

cwSonetPathIntervalLineNum 1.3.6.1.4.1.351.110.4.6.1.5.3.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetPathIntervalNumber 1.3.6.1.4.1.351.110.4.6.1.5.3.1.2
A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
OBJECT-TYPE    
  INTEGER 1..96  

cwSonetPathIntervalValidFlag 1.3.6.1.4.1.351.110.4.6.1.5.3.1.3
Indicates if the bucket specified by the interval is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetPathIntervalESs 1.3.6.1.4.1.351.110.4.6.1.5.3.1.4
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetPathIntervalSESs 1.3.6.1.4.1.351.110.4.6.1.5.3.1.5
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetPathIntervalCVs 1.3.6.1.4.1.351.110.4.6.1.5.3.1.6
The counter associated with the number of Coding Violations encountered by a SONET/SDH Path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetPathIntervalFCs 1.3.6.1.4.1.351.110.4.6.1.5.3.1.7
Number of times that Path was in AIS or LOP alarm in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetPathIntervalUASs 1.3.6.1.4.1.351.110.4.6.1.5.3.1.8
The counter associated with the number of Unavailable Seconds encountered by a Path in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathCurrentTable 1.3.6.1.4.1.351.110.4.6.1.5.4
The SONET/SDH Far End Path Current table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetFarEndPathCurrentEntry

cwSonetFarEndPathCurrentEntry 1.3.6.1.4.1.351.110.4.6.1.5.4.1
An entry in the SONET/SDH Far End Path Current table.
OBJECT-TYPE    
  CwSonetFarEndPathCurrentEntry  

cwSonetFEPathCurrentLineNum 1.3.6.1.4.1.351.110.4.6.1.5.4.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetFarEndPathCurrentValidFlag 1.3.6.1.4.1.351.110.4.6.1.5.4.1.2
Indicates if the Far End current 15min bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetFarEndPathCurrentTimeElapsed 1.3.6.1.4.1.351.110.4.6.1.5.4.1.3
The number of seconds, including partial seconds, that have elapsed since the beginning of the 15min error-measurement period.
OBJECT-TYPE    
  INTEGER 1..900  

cwSonetFarEndPathCurrentESs 1.3.6.1.4.1.351.110.4.6.1.5.4.1.4
The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathCurrentSESs 1.3.6.1.4.1.351.110.4.6.1.5.4.1.5
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathCurrentCVs 1.3.6.1.4.1.351.110.4.6.1.5.4.1.6
The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Path interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathCurrentFCs 1.3.6.1.4.1.351.110.4.6.1.5.4.1.7
The counter associated with the number of RFIs in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathCurrentUASs 1.3.6.1.4.1.351.110.4.6.1.5.4.1.8
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in the current 15 minute interval.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathCurrentClrButton 1.3.6.1.4.1.351.110.4.6.1.5.4.1.9
Clears all the Far End Path Current counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

sonetFarEndPathCurrentDayTable 1.3.6.1.4.1.351.110.4.6.1.5.5
The SONET/SDH Far End Path CurrentDay table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetFarEndPathCurrentDayEntry

sonetFarEndPathCurrentDayEntry 1.3.6.1.4.1.351.110.4.6.1.5.5.1
An entry in the SONET/SDH Far End Path CurrentDay table.
OBJECT-TYPE    
  SonetFarEndPathCurrentDayEntry  

sonetFEPathCurrentDayLineNum 1.3.6.1.4.1.351.110.4.6.1.5.5.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetFarEndPathCurrentDayValidFlag 1.3.6.1.4.1.351.110.4.6.1.5.5.1.2
Indicates if the Far End current day bucket is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

sonetFarEndPathCurrentDayESs 1.3.6.1.4.1.351.110.4.6.1.5.5.1.3
The counter associated with the number of Far Far End Errored Seconds encountered by a SONET/SDH interface in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndPathCurrentDaySESs 1.3.6.1.4.1.351.110.4.6.1.5.5.1.4
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndPathCurrentDayCVs 1.3.6.1.4.1.351.110.4.6.1.5.5.1.5
The counter associated with the number of Far End Coding Violations reported via the far end block error (FEBE) count encountered by a SONET/SDH Path interface in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndPathCurrentDayFCs 1.3.6.1.4.1.351.110.4.6.1.5.5.1.6
The counter associated with the number of RFIs in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndPathCurrentDayUASs 1.3.6.1.4.1.351.110.4.6.1.5.5.1.7
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in the Current day interval.
OBJECT-TYPE    
  Gauge  

sonetFarEndPathCurrentDayClrButton 1.3.6.1.4.1.351.110.4.6.1.5.5.1.8
Clears all the Far End Path CurrentDay counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

cwSonetFarEndPathIntervalTable 1.3.6.1.4.1.351.110.4.6.1.5.6
The SONET/SDH Far End Path Interval table.
OBJECT-TYPE    
  SEQUENCE OF  
    CwSonetFarEndPathIntervalEntry

cwSonetFarEndPathIntervalEntry 1.3.6.1.4.1.351.110.4.6.1.5.6.1
An entry in the SONET/SDH Far End Path Interval table.
OBJECT-TYPE    
  CwSonetFarEndPathIntervalEntry  

cwSonetFEPathIntervalLineNum 1.3.6.1.4.1.351.110.4.6.1.5.6.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

cwSonetFarEndPathIntervalNumber 1.3.6.1.4.1.351.110.4.6.1.5.6.1.2
A number between 1 and 96, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
OBJECT-TYPE    
  INTEGER 1..96  

cwSonetFarEndPathIntervalValidFlag 1.3.6.1.4.1.351.110.4.6.1.5.6.1.3
Indicates if the bucket specified by the interval is valid or not.
OBJECT-TYPE    
  INTEGER notValid(1), valid(2)  

cwSonetFarEndPathIntervalESs 1.3.6.1.4.1.351.110.4.6.1.5.6.1.4
The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathIntervalSESs 1.3.6.1.4.1.351.110.4.6.1.5.6.1.5
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathIntervalCVs 1.3.6.1.4.1.351.110.4.6.1.5.6.1.6
The counter associated with the number of Far End Coding Violations reported via the far end block error count encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathIntervalFCs 1.3.6.1.4.1.351.110.4.6.1.5.6.1.7
The counter associated with the number of RFIs in in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

cwSonetFarEndPathIntervalUASs 1.3.6.1.4.1.351.110.4.6.1.5.6.1.8
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path interface in a particular 15-minute interval in the past 24 hours.
OBJECT-TYPE    
  Gauge  

sonetPathAlarmTable 1.3.6.1.4.1.351.110.4.6.1.5.7
The SONET/SDH Path Alarm table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetPathAlarmEntry

sonetPathAlarmEntry 1.3.6.1.4.1.351.110.4.6.1.5.7.1
An entry in the SONET/SDH Path Alarm table.
OBJECT-TYPE    
  SonetPathAlarmEntry  

sonetPathAlarmLineNum 1.3.6.1.4.1.351.110.4.6.1.5.7.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetPathStatisticalAlarmSeverity 1.3.6.1.4.1.351.110.4.6.1.5.7.1.2
When any statistical threshold is exceeded.
OBJECT-TYPE    
  INTEGER minor(1), major(2)  

sonetPathCurrent15minESsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.3
The default is set to 20. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathCurrentDayESsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.4
The default is set to 200. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathCurrent15minSESsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.5
The default is set to 3. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathCurrentDaySESsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.6
The default is set to 7. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathCurrent15minCVsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.7
The default is set to 25. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathCurrentDayCVsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.8
The default is set to 250. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathCurrent15minUASsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.9
The default is set to 10. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathCurrentDayUASsThreshold 1.3.6.1.4.1.351.110.4.6.1.5.7.1.10
The default is set to 10. This threshold is the same for Far End and Near End.
OBJECT-TYPE    
  INTEGER 0..2147483647  

sonetPathTraceSelection 1.3.6.1.4.1.351.110.4.6.1.5.7.1.11
Sonet Path Trace Selection.
OBJECT-TYPE    
  INTEGER none(1), sixtyFourBytes(2), sixtyFourBytesCrlf(3), sixteenBytes(4), sixteenBytesCrc7(5), sixteenBytesMsb1(6)  

sonetPathTraceToTransmit 1.3.6.1.4.1.351.110.4.6.1.5.7.1.12
Sonet Path Trace To Transmit. 64-bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string.
OBJECT-TYPE    
  OCTET STRING SIZE(0..64)  

sonetPathTraceToExpect 1.3.6.1.4.1.351.110.4.6.1.5.7.1.13
Sonet Path Trace To Expect. 64-bytes String. If 16 byte trace is selected, FW will only use bytes 0-15 of the string.
OBJECT-TYPE    
  OCTET STRING SIZE(0..64)  

sonetPathTraceReceived 1.3.6.1.4.1.351.110.4.6.1.5.7.1.14
Sonet Path Trace Received. 64-bytes String. The write option is for debugging only.
OBJECT-TYPE    
  OCTET STRING SIZE(0..64)  

sonetPathStatAlarmStatus 1.3.6.1.4.1.351.110.4.6.1.5.7.1.15
This variable indicates the status of the interface. The sonetPathStatAlarmStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetPathStatAlarmNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetPathStatAlarmNoDefect 2 sonetPathCurrent15minESs 3 sonetPathCurrent15minSESs 4 sonetPathCurrent15minCVs 5 sonetPathCurrent15minUASs 6 sonetFarEndPathCurrent15minESs 7 sonetFarEndPathCurrent15minSESs 8 sonetFarEndPathCurrent15minCVs 9 sonetFarEndPathCurrent15minUASs 10 sonetPathCurrentDayESs 11 sonetPathCurrentDaySESs 12 sonetPathCurrentDayCVs 13 sonetPathCurrentDayUASs 14 sonetFarEndPathCurrentDayESs 15 sonetFarEndPathCurrentDaySESs 16 sonetFarEndPathCurrentDayCVs 17 sonetFarEndPathCurrentDayUASs
OBJECT-TYPE    
  INTEGER 1..'1FFFF'h  

sonetPathCounterTable 1.3.6.1.4.1.351.110.4.6.1.5.8
The SONET/SDH Path Counter table.
OBJECT-TYPE    
  SEQUENCE OF  
    SonetPathCounterEntry

sonetPathCounterEntry 1.3.6.1.4.1.351.110.4.6.1.5.8.1
An entry in the SONET/SDH Path table.
OBJECT-TYPE    
  SonetPathCounterEntry  

sonetPathCounterLineNum 1.3.6.1.4.1.351.110.4.6.1.5.8.1.1
line number. BNM has one line
OBJECT-TYPE    
  INTEGER 1..1  

sonetPathCounterAISs 1.3.6.1.4.1.351.110.4.6.1.5.8.1.2
The counter associated with the number of AISs encountered by a SONET/SDH.
OBJECT-TYPE    
  Gauge  

sonetPathCounterRFIs 1.3.6.1.4.1.351.110.4.6.1.5.8.1.3
The counter associated with the number of RFIs encountered by a SONET/SDH Path.
OBJECT-TYPE    
  Gauge  

sonetPathCounterClrButton 1.3.6.1.4.1.351.110.4.6.1.5.8.1.4
Clears all the Path's counters.
OBJECT-TYPE    
  INTEGER noAction(1), clear(2)  

sonetApsConfig 1.3.6.1.4.1.351.110.4.6.1.6
OBJECT IDENTIFIER    

sonetApsConfigTable 1.3.6.1.4.1.351.110.4.6.1.6.1
The Sonet APS config table
OBJECT-TYPE    
  SEQUENCE OF  
    SonetApsConfigEntry

sonetApsConfigEntry 1.3.6.1.4.1.351.110.4.6.1.6.1.1
An entry in the Sonet APS table. Each Entry is index by the working Line number.
OBJECT-TYPE    
  SonetApsConfigEntry  

apsWorkingSlot 1.3.6.1.4.1.351.110.4.6.1.6.1.1.1
This object is the chassis slot number of the working line MGX 8x50 PXM: can only be slot 7 or 8. MGX 8x30 PXM: can only be slot 1 or 2. MGX 8x50 SRME: can only be slot 15,16,31 or 32 MGX 8x30 SRME: can only be slot 7 or 14
OBJECT-TYPE    
  INTEGER 1..32  

apsWorkingLine 1.3.6.1.4.1.351.110.4.6.1.6.1.1.2
This object is the line number of the working line OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid number
OBJECT-TYPE    
  INTEGER 1..4  

apsProtectionSlot 1.3.6.1.4.1.351.110.4.6.1.6.1.1.3
This object is the chassis slot number of the protection line MGX 8x50 PXM: can only be slot 7 or 8. MGX 8x30 PXM: can only be slot 1 or 2. MGX 8x50 SRME: can only be slot 15,16,31 or 32 MGX 8x30 SRME: can only be slot 7 or 14
OBJECT-TYPE    
  INTEGER 1..32  

apsProtectionLine 1.3.6.1.4.1.351.110.4.6.1.6.1.1.4
This object is the line number of the working line OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid number
OBJECT-TYPE    
  INTEGER 1..4  

apsEnable 1.3.6.1.4.1.351.110.4.6.1.6.1.1.5
This object is used to enable or disable APS feature on the working/protection line pairs.
OBJECT-TYPE    
  INTEGER apsFeatDisable(1), apsFeatEnable(2)  

apsArchMode 1.3.6.1.4.1.351.110.4.6.1.6.1.1.6
This object is used to configure APS architecture mode on the working/protection line pairs. The architecture modes currently supported are 'dualCardonePlusOne' (for GR-253) and 'anexAOnePlusOne (for G.783 Annex A).
OBJECT-TYPE    
  INTEGER singleCardonePlusOne(1), dualCardonePlusOne(2), singleCardOneToOne(3), anexBOnePlusOne(4), anexAOnePlusOne(5)  

apsActiveLine 1.3.6.1.4.1.351.110.4.6.1.6.1.1.7
This object indicates which line is currently active ob the trunk line.
OBJECT-TYPE    
  INTEGER apsWorkingLine(1), apsProtectionLine(2)  

apsSFBER 1.3.6.1.4.1.351.110.4.6.1.6.1.1.8
This object contains the Bit Error Rate threshold for Signal Fault detection on the working line.
OBJECT-TYPE    
  INTEGER 3..13  

apsSDBER 1.3.6.1.4.1.351.110.4.6.1.6.1.1.9
This object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. If set to 5, it means SDBER rate = 10 ^^ -5.
OBJECT-TYPE    
  INTEGER 5..13  

apsWtr 1.3.6.1.4.1.351.110.4.6.1.6.1.1.10
This object contains interval (in minute) to wait before attempting to switch back to working line. Not applicable if the line configure in non-revertive mode.
OBJECT-TYPE    
  INTEGER 0..12  

apsdirection 1.3.6.1.4.1.351.110.4.6.1.6.1.1.11
This object is used to configure the switching direction which this APS line support. Unidirectional switch only one direction. Bidirectional switch in both ends of the line.
OBJECT-TYPE    
  INTEGER uniDirectional(1), biDirectional(2)  

apsRevertive 1.3.6.1.4.1.351.110.4.6.1.6.1.1.12
This object is used to configure the APS revertive or nonrevertive option. Revertive allows the line to be switch back to working line after the Wait-To-restore interval has expired and the working line SF/SD has been cleared.
OBJECT-TYPE    
  INTEGER nonrevertive(1), revertive(2)  

apsK1K2Disable 1.3.6.1.4.1.351.110.4.6.1.6.1.1.13
This object is used to enable or disable the K1/K2 inband interface on the protection line.
OBJECT-TYPE    
  INTEGER kbandEnable(1), kbandDisable(2)  

apsCardFailureCode 1.3.6.1.4.1.351.110.4.6.1.6.2
The Sonet APS card failure code apsProtectBCMissing = protection Back card missing apsProtectDCMissing = protection Daughter card missing apsWorkingBCMissing = Working Back card missing apsWorkingDCMissing = Working Daughter card missing apsWorkingCdMismatch = Working Card in mismatch/fail state apsProtectCdMismatch = protection card in mismatch/fail state
OBJECT-TYPE    
  INTEGER apsProtectBCMissing(1), apsProtectDCMissing(2), apsWorkingBCMissing(3), apsWorkingDCMissing(4), apsWorkingCdMismatch(5), apsProtectCdMismatch(6)  

apsLineFailureCode 1.3.6.1.4.1.351.110.4.6.1.6.3
The Sonet APS line failure code
OBJECT-TYPE    
  INTEGER apsSignalDegrade(1), apsSignalFailure(2), apsLineAlarm(3), apsLineLoopBack(4)  

apsLineSwReason 1.3.6.1.4.1.351.110.4.6.1.6.4
The Sonet APS line switch reason code
OBJECT-TYPE    
  INTEGER apsRevertive(1), apsManual(2), apsSignalDefectLow(3), apsSignalDefectHigh(4), apsSignalFailureLow(5), apsSignalFailureHigh(6), apsForceSwitch(7), apsLockOut(8)  

apsLineSwFailureCode 1.3.6.1.4.1.351.110.4.6.1.6.5
The Sonet APS line switch failure code
OBJECT-TYPE    
  INTEGER apsRevertiveSwitchFail(1), apsManualSwitchFail(2), apsSDLowSwitchFail(3), apsSDHighSwitchFail(4), apsSFLowSwitchFail(5), apsSFHighSwitchFail(6), apsForceSwitchFail(7), apsLockOutSwitchFail(8)  

apsStandbyLineFailureCode 1.3.6.1.4.1.351.110.4.6.1.6.6
The Sonet APS standby line failure code
OBJECT-TYPE    
  INTEGER apsSignalDegrade(1), apsSignalFailure(2), apsLineAlarm(3), apsLineLoopBack(4), apsProtectionByteFail(5), apsArchitectureMismatch(6), apsChannelMismatch(7), apsDirectionMismatch(8), apsWrongRequest(9)  

Defined Objects

SonetConfigEntry  
SEQUENCE    
  INTEGER as sonetLineNum  
  INTEGER as sonetLineType  
  INTEGER as sonetLineLoopbackCommand  
  INTEGER as sonetHCSmasking  
  INTEGER as sonetPayloadScrambling  
  INTEGER as sonetFrameScrambling  
  INTEGER as sonetLineEnable  
  INTEGER as sonetLineXmtClkSrc  
  INTEGER as sonetRDIVType  
  INTEGER as sonetRDIPType  
  INTEGER as sonetTributaryType  
  INTEGER as sonetTributaryMappingType  
  INTEGER as sonetTributaryFramingFormat  
  INTEGER as sonetSignallingTransportMode  
  INTEGER as sonetTributaryGroupingType  

CwSonetMediumEntry  
SEQUENCE    
  INTEGER as cwSonetMediumType  
  INTEGER as cwSonetMediumTimeElapsed  
  INTEGER as cwSonetMediumValidIntervals  
  INTEGER as cwSonetMediumLineCoding  
  INTEGER as cwSonetMediumLineType  
  DisplayString as cwSonetMediumCircuitIdentifier  

CwSonetSectionCurrentEntry  
SEQUENCE    
  INTEGER as cwSonetSectionCurrentLineNum  
  INTEGER as cwSonetSectionCurrentStatus  
  INTEGER as cwSonetSectionCurrentValidFlag  
  INTEGER as cwSonetSectionCurrent15minTimeElapsed  
  Counter as cwSonetSectionCurrentESs  
  Counter as cwSonetSectionCurrentSESs  
  Counter as cwSonetSectionCurrentSEFSs  
  Counter as cwSonetSectionCurrentCVs  
  INTEGER as cwSonetSectionCurrentClrButton  

SonetSectionCurrentDayEntry  
SEQUENCE    
  INTEGER as sonetSectionCurrentDayLineNum  
  INTEGER as sonetSectionCurrentDayValidFlag  
  Counter as sonetSectionCurrentDayESs  
  Counter as sonetSectionCurrentDaySESs  
  Counter as sonetSectionCurrentDaySEFSs  
  Counter as sonetSectionCurrentDayCVs  
  INTEGER as sonetSectionCurrentDayClrButton  

CwSonetSectionIntervalEntry  
SEQUENCE    
  INTEGER as cwSonetSectionIntervalLineNum  
  INTEGER as cwSonetSectionIntervalNumber  
  INTEGER as cwSonetSectionIntervalValidFlag  
  Counter as cwSonetSectionIntervalESs  
  Counter as cwSonetSectionIntervalSESs  
  Counter as cwSonetSectionIntervalSEFss  
  Counter as cwSonetSectionIntervalCVs  

SonetSectionAlarmEntry  
SEQUENCE    
  INTEGER as sectionAlarmLineNum  
  INTEGER as sonetSectionStatisticalAlarmSeverity  
  INTEGER as sonetSectionCurrent15minESsThreshold  
  INTEGER as sonetSectionCurrentDayESsThreshold  
  INTEGER as sonetSectionCurrent15minSESsThreshold  
  INTEGER as sonetSectionCurrentDaySESsThreshold  
  INTEGER as sonetSectionCurrent15minSEFSsThreshold  
  INTEGER as sonetSectionCurrentDaySEFSsThreshold  
  INTEGER as sonetSectionCurrent15minCVsThreshold  
  INTEGER as sonetSectionCurrentDayCVsThreshold  
  INTEGER as sonetSectionTraceSelection  
  OCTET STRING as sonetSectionTraceToTransmit  
  OCTET STRING as sonetSectionTraceToExpect  
  OCTET STRING as sonetSectionTraceReceived  
  INTEGER as sonetSectionStatAlarmStatus  

SonetSectionCounterEntry  
SEQUENCE    
  INTEGER as sectionCounterLineNum  
  Gauge as sonetSectionCounterLOSs  
  Gauge as sonetSectionCounterLOFs  
  INTEGER as sonetSectionCounterClrButton  

CwSonetLineCurrentEntry  
SEQUENCE    
  INTEGER as cwSonetLineCurrentLineNum  
  INTEGER as cwSonetLineCurrentStatus  
  INTEGER as cwSonetLineCurrentValidFlag  
  INTEGER as cwSonetLineCurrent15minTimeElapsed  
  Gauge as cwSonetLineCurrentESs  
  Gauge as cwSonetLineCurrentSESs  
  Gauge as cwSonetLineCurrentCVs  
  Gauge as cwSonetLineCurrentUASs  
  INTEGER as cwSonetLineCurrentClrButton  

SonetLineCurrentDayEntry  
SEQUENCE    
  INTEGER as lineCurrentDayLineNum  
  INTEGER as sonetLineCurrentDayValidFlag  
  Gauge as sonetLineCurrentDayESs  
  Gauge as sonetLineCurrentDaySESs  
  Gauge as sonetLineCurrentDayCVs  
  Gauge as sonetLineCurrentDayFCs  
  Gauge as sonetLineCurrentDayUASs  
  INTEGER as sonetLineCurrentDayClrButton  

CwSonetLineIntervalEntry  
SEQUENCE    
  INTEGER as cwSonetLineIntervalLineNum  
  INTEGER as cwSonetLineIntervalNumber  
  INTEGER as cwSonetLineIntervalValidFlag  
  Gauge as cwSonetLineIntervalESs  
  Gauge as cwSonetLineIntervalSESs  
  Gauge as cwSonetLineIntervalCVs  
  Gauge as cwSonetLineIntervalFCs  
  Gauge as cwSonetLineIntervalUASs  

CwSonetFarEndLineCurrentEntry  
SEQUENCE    
  INTEGER as cwSonetFELineCurrentLineNum  
  INTEGER as cwSonetFarEndLineCurrentValidFlag  
  INTEGER as cwSonetFarEndLineCurrentTimeElapsed  
  Gauge as cwSonetFarEndLineCurrentESs  
  Gauge as cwSonetFarEndLineCurrentSESs  
  Gauge as cwSonetFarEndLineCurrentCVs  
  Gauge as cwSonetFarEndLineCurrentFCs  
  Gauge as cwSonetFarEndLineCurrentUASs  
  INTEGER as cwSonetFarEndLineCurrentClrButton  

SonetFarEndLineCurrentDayEntry  
SEQUENCE    
  INTEGER as sonetFELineCurrentDayLineNum  
  INTEGER as sonetFarEndLineCurrentDayValidFlag  
  Gauge as sonetFarEndLineCurrentDayESs  
  Gauge as sonetFarEndLineCurrentDaySESs  
  Gauge as sonetFarEndLineCurrentDayCVs  
  Gauge as sonetFarEndLineCurrentDayFCs  
  Gauge as sonetFarEndLineCurrentDayUASs  
  INTEGER as sonetFarEndLineCurrentDayClrButton  

CwSonetFarEndLineIntervalEntry  
SEQUENCE    
  INTEGER as cwSonetFELineIntervalLineNum  
  INTEGER as cwSonetFarEndLineIntervalNumber  
  INTEGER as cwSonetFarEndLineIntervalValidFlag  
  Gauge as cwSonetFarEndLineIntervalESs  
  Gauge as cwSonetFarEndLineIntervalSESs  
  Gauge as cwSonetFarEndLineIntervalCVs  
  Gauge as cwSonetFarEndLineIntervalFCs  
  Gauge as cwSonetFarEndLineIntervalUASs  

SonetLineAlarmEntry  
SEQUENCE    
  INTEGER as sonetLineAlarmLineNum  
  INTEGER as sonetLineStatisticalAlarmSeverity  
  INTEGER as sonetLineCurrent15minESsThreshold  
  INTEGER as sonetLineCurrentDayESsThreshold  
  INTEGER as sonetLineCurrent15minSESsThreshold  
  INTEGER as sonetLineCurrentDaySESsThreshold  
  INTEGER as sonetLineCurrent15minCVsThreshold  
  INTEGER as sonetLineCurrentDayCVsThreshold  
  INTEGER as sonetLineCurrent15minUASsThreshold  
  INTEGER as sonetLineCurrentDayUASsThreshold  
  INTEGER as sonetLineStatAlarmStatus  

SonetLineCounterEntry  
SEQUENCE    
  INTEGER as sonetLineCounterLineNum  
  Gauge as sonetLineCounterAISs  
  Gauge as sonetLineCounterRFIs  
  INTEGER as sonetLineCounterClrButton  

CwSonetPathCurrentEntry  
SEQUENCE    
  INTEGER as cwSonetPathCurrentLineNum  
  INTEGER as cwSonetPathCurrentStatus  
  INTEGER as cwSonetPathCurrentValidFlag  
  INTEGER as cwSonetPathCurrentTimeElapsed  
  Gauge as cwSonetPathCurrentESs  
  Gauge as cwSonetPathCurrentSESs  
  Gauge as cwSonetPathCurrentCVs  
  Gauge as cwSonetPathCurrentFCs  
  Gauge as cwSonetPathCurrentUASs  
  INTEGER as cwSonetPathCurrentClrButton  

SonetPathCurrentDayEntry  
SEQUENCE    
  INTEGER as sonetPathCurrentDayLineNum  
  INTEGER as sonetPathCurrentDayValidFlag  
  Gauge as sonetPathCurrentDayESs  
  Gauge as sonetPathCurrentDaySESs  
  Gauge as sonetPathCurrentDayCVs  
  Gauge as sonetPathCurrentDayFCs  
  Gauge as sonetPathCurrentDayUASs  
  INTEGER as sonetPathCurrentDayClrButton  

CwSonetPathIntervalEntry  
SEQUENCE    
  INTEGER as cwSonetPathIntervalLineNum  
  INTEGER as cwSonetPathIntervalNumber  
  INTEGER as cwSonetPathIntervalValidFlag  
  Gauge as cwSonetPathIntervalESs  
  Gauge as cwSonetPathIntervalSESs  
  Gauge as cwSonetPathIntervalCVs  
  Gauge as cwSonetPathIntervalFCs  
  Gauge as cwSonetPathIntervalUASs  

CwSonetFarEndPathCurrentEntry  
SEQUENCE    
  INTEGER as cwSonetFEPathCurrentLineNum  
  INTEGER as cwSonetFarEndPathCurrentValidFlag  
  INTEGER as cwSonetFarEndPathCurrentTimeElapsed  
  Gauge as cwSonetFarEndPathCurrentESs  
  Gauge as cwSonetFarEndPathCurrentSESs  
  Gauge as cwSonetFarEndPathCurrentCVs  
  Gauge as cwSonetFarEndPathCurrentFCs  
  Gauge as cwSonetFarEndPathCurrentUASs  
  INTEGER as cwSonetFarEndPathCurrentClrButton  

SonetFarEndPathCurrentDayEntry  
SEQUENCE    
  INTEGER as sonetFEPathCurrentDayLineNum  
  INTEGER as sonetFarEndPathCurrentDayValidFlag  
  Gauge as sonetFarEndPathCurrentDayESs  
  Gauge as sonetFarEndPathCurrentDaySESs  
  Gauge as sonetFarEndPathCurrentDayCVs  
  Gauge as sonetFarEndPathCurrentDayFCs  
  Gauge as sonetFarEndPathCurrentDayUASs  
  INTEGER as sonetFarEndPathCurrentDayClrButton  

CwSonetFarEndPathIntervalEntry  
SEQUENCE    
  INTEGER as cwSonetFEPathIntervalLineNum  
  INTEGER as cwSonetFarEndPathIntervalNumber  
  INTEGER as cwSonetFarEndPathIntervalValidFlag  
  Gauge as cwSonetFarEndPathIntervalESs  
  Gauge as cwSonetFarEndPathIntervalSESs  
  Gauge as cwSonetFarEndPathIntervalCVs  
  Gauge as cwSonetFarEndPathIntervalFCs  
  Gauge as cwSonetFarEndPathIntervalUASs  

SonetPathAlarmEntry  
SEQUENCE    
  INTEGER as sonetPathAlarmLineNum  
  INTEGER as sonetPathStatisticalAlarmSeverity  
  INTEGER as sonetPathCurrent15minESsThreshold  
  INTEGER as sonetPathCurrentDayESsThreshold  
  INTEGER as sonetPathCurrent15minSESsThreshold  
  INTEGER as sonetPathCurrentDaySESsThreshold  
  INTEGER as sonetPathCurrent15minCVsThreshold  
  INTEGER as sonetPathCurrentDayCVsThreshold  
  INTEGER as sonetPathCurrent15minUASsThreshold  
  INTEGER as sonetPathCurrentDayUASsThreshold  
  INTEGER as sonetPathTraceSelection  
  OCTET STRING as sonetPathTraceToTransmit  
  OCTET STRING as sonetPathTraceToExpect  
  OCTET STRING as sonetPathTraceReceived  
  INTEGER as sonetPathStatAlarmStatus  

SonetPathCounterEntry  
SEQUENCE    
  INTEGER as sonetPathCounterLineNum  
  Gauge as sonetPathCounterAISs  
  Gauge as sonetPathCounterRFIs  
  INTEGER as sonetPathCounterClrButton  

SonetApsConfigEntry  
SEQUENCE    
  INTEGER as apsWorkingSlot  
  INTEGER as apsWorkingLine  
  INTEGER as apsProtectionSlot  
  INTEGER as apsProtectionLine  
  INTEGER as apsEnable  
  INTEGER as apsArchMode  
  INTEGER as apsActiveLine  
  INTEGER as apsSFBER  
  INTEGER as apsSDBER  
  INTEGER as apsWtr  
  INTEGER as apsdirection  
  INTEGER as apsRevertive  
  INTEGER as apsK1K2Disable